Vous êtes sur la page 1sur 23

OTIS - OEC CUSTOMER SERVICE TOOL Dwg : GAA25NC

Date : 2007-10-26
ENGINEERING CENTER
BERLIN GECB Page : 1/23

FSM Owners Information Manual

GECB
Owners Information Manual

Authorization Date:

Running on PCB: GECB-EN: GBA26800LJ...

R Software Version: GECB: GAA 30780 DAB

Document Revision :

Date Author Page Comment


2007-02-28 M. TOUTAOUI 23 Original document
2007-10-26 M. TOUTAOUI 23 Chapter 6.2 enhanced

Copyright © OTIS Elevator Company


OTIS - OEC CUSTOMER SERVICE TOOL Dwg : GAA25NC
Date : 2007-10-26
ENGINEERING CENTER
BERLIN GECB Page : 2/23

FSM Owners Information Manual

CONTENTS
1 SERVICE TOOL TREE STRUCTURE ............................................................................................................ 3

2 STATUS DISPLAY .......................................................................................................................................... 4


2.1 MOTION STATE .............................................................................................................................................. 5
2.2 OPERATIONAL MODE ...................................................................................................................................... 6
3 STATUS CALLS MENU .................................................................................................................................. 7

4 STATUS INPUTS MENU................................................................................................................................. 8


4.1 SYSTEM INPUTS ............................................................................................................................................. 9
5 STATUS OUTPUTS MENU........................................................................................................................... 14
5.1 SYSTEM OUTPUTS ........................................................................................................................................ 14
6 TEST EVENTS MENU................................................................................................................................... 16
6.1 VIEW EVENTS .............................................................................................................................................. 16
6.2 ERASE EVENTS ............................................................................................................................................ 17
7 TEST SELFTEST MENU............................................................................................................................... 18

8 INFO MESSAGES ......................................................................................................................................... 19

9 APPENDIX..................................................................................................................................................... 20
9.1 EVENT LOGGING .......................................................................................................................................... 20

Copyright © OTIS Elevator Company


OTIS - OEC CUSTOMER SERVICE TOOL Dwg : GAA25NC
Date : 2007-10-26
ENGINEERING CENTER
BERLIN GECB Page : 3/23

FSM Owners Information Manual

1 Service Tool tree structure

Copyright © OTIS Elevator Company


OTIS - OEC CUSTOMER SERVICE TOOL Dwg : GAA25NC
Date : 2007-10-26
ENGINEERING CENTER
BERLIN GECB Page : 4/23

FSM Owners Information Manual

2 Status display

Copyright © OTIS Elevator Company


OTIS - OEC CUSTOMER SERVICE TOOL Dwg : GAA25NC
Date : 2007-10-26
ENGINEERING CENTER
BERLIN GECB Page : 5/23

FSM Owners Information Manual

2.1 Motion State


State Description
CR Correction Run
EF Emergency Fast run
ES Emergency Stop
EW Emergency during Wait
FR Fast Run
ID IDle
IN INspection Run
NR Not Ready
RL Relevel
RS ReScue Run
SR Slow Run
ST STop

Copyright © OTIS Elevator Company


OTIS - OEC CUSTOMER SERVICE TOOL Dwg : GAA25NC
Date : 2007-10-26
ENGINEERING CENTER
BERLIN GECB Page : 6/23

FSM Owners Information Manual

2.2 Operational mode


Mode Description
ACP Anti Crime Protection
ANS Anti Nuisance Service
ARD Automatic Return Device
ATT ATTendend service
CBP Car Button Protection
CHC Cut off Hall Call
COR COrrection Run
CTL Car To Landing
DBF Drive / Break Fault
DCP Delayed Car Protection
DCS Door Check Sequence
DHB Door Hold Button mode
DLM Door Lock Monitoring
DTC Door Time protection Close
DTO Door Time protection Open
EFO Emergency Fireman's Operation
EFS Emergency Fireman's Service
EHS Emergency Hospital Service
EMT Emergency Medical Transport
EPC Emergency Power wait for Correction run
EPR Emergency Power Rescue run
EPW Emergency Power Wait for normal
EQO Earth Quake Operation
ESB Emergency Stop Button resp. J-Relay fault
GCB General Control of Buttons
HAD Hoistway Access Detection
HBP Hall Button Protection
IDL IDLe
INI INItialize
INS INSpection
ISC Independent ServiCe
LNS Load Non Stop service
MIT Moderate Incoming Traffic
NAV Not AVailable
NOR NORmal
OLD OverLoad Device
PKS ParKing Switch
PRK PaRKing
ROT car RiOT operation
SHO SHabat Operation
WCO Wild Car Operation

Copyright © OTIS Elevator Company


OTIS - OEC CUSTOMER SERVICE TOOL Dwg : GAA25NC
Date : 2007-10-26
ENGINEERING CENTER
BERLIN GECB Page : 7/23

FSM Owners Information Manual

3 Status Calls Menu

Copyright © OTIS Elevator Company


OTIS - OEC CUSTOMER SERVICE TOOL Dwg : GAA25NC
Date : 2007-10-26
ENGINEERING CENTER
BERLIN GECB Page : 8/23

FSM Owners Information Manual

4 Status Inputs Menu

Copyright © OTIS Elevator Company


OTIS - OEC CUSTOMER SERVICE TOOL Dwg : GAA25NC
Date : 2007-10-26
ENGINEERING CENTER
BERLIN GECB Page : 9/23

FSM Owners Information Manual

4.1 System inputs


Input Group Description
ES Safety Chain Emergency Stop switch
DW door open contact
DFC Door Fully Closed contact
GDS Gate Door Switch

SE Start Enable Start Enable


1TH Thermal contact 1
2TH Thermal contact 2

TCI Inspection Top of Car Inspection switch


UIB Up Inspection Button
DIB Down Inspection Button
ERO Emergency Recall Operation switch
TDO Top of Car Door Open Button
TDC Top of Car Door Close Button
^TDO rear Top of Car Door Open Button
^TDC rear Top of Car Door Close Button
TCB Top of Car Inspection Button (TCIB)

DZ Doorzone Door Zone (LV1 and/or LV2)


1LV Door Zone switch 1LV
2LV Door Zone switch 2LV

1LS Limit Switches Limit Switch 1


2LS Limit Switch 2

BY Drive BY-Relay
BRK BR-Relay

LWO Load Weighing overload signal LWO


LWX load weighing bypass LWX
LNS Load Non Stop
L30 30% load in car
L50 50% load in car

DOL Front Door Door Open Limit switch


DCL Door Close Limit switch
DOB Door Open Button
DCB Door Close Button
EDP Electronic Door Protection
LRD Light Ray Device
DOS Door Open Signal

Copyright © OTIS Elevator Company


OTIS - OEC CUSTOMER SERVICE TOOL Dwg : GAA25NC
Date : 2007-10-26
ENGINEERING CENTER
BERLIN GECB Page : 10/23

FSM Owners Information Manual

Input Group Description


GSM Gate Switch Monitor
MDD Moving at front of Door Detection
DHB Door Hold Button
SDB Special Door Open Button

^DOL Rear Door rear Door Open Limit switch


^DCL rear Door Close Limit switch
^DOB rear Door Open Button
^DCB rear Door Close Button
^EDP rear Electronic Door Protection
^LRD rear Light Ray Device
^DOS rear Door Open Signal
^GSM rear Gate Switch Monitor
^MDD Moving at rear of Door Detection
^DHB rear Door Hold Button
^SDB rear Special Door Open Button

CCT Switches Car Call to Top


CCB Car Call to Bottom
CHC Cut off Hall Call
DDO Disable Door Operation
RTB Remote Tripping Button
RRB Remote Resetting Button

EFO Emergency Emergency Firemen Operation


HTS Hall Temperature Sensor from SPB
AEF Alternative EFO (AEFO)
EFK Emergency Fireman Key
ASL Alternative Service Landing
ESK Emergency Service Key switch
ESH Emergency Service Hold switch
CFS Car Fireman Service switch (Australia)
CS Car fireman service Start switch (Australia)
XEF Overide EFO
EFB Emergency Firemen Key Bypass (EFKB)
ADB Alternative Door Button
EDB EFO Door Button
1EF Taiwan Fireman Service Key switch 1
2EF Taiwan Fireman Service Key switch 2
DDS Disable Door Switch Relay
DES Disable EEC Relay

NU Emerg. Power emergency power operation signal


NUD emergency power operation signal
NUG emergency power operation signal

Copyright © OTIS Elevator Company


OTIS - OEC CUSTOMER SERVICE TOOL Dwg : GAA25NC
Date : 2007-10-26
ENGINEERING CENTER
BERLIN GECB Page : 11/23

FSM Owners Information Manual

Input Group Description


NRF NURF

EQ1 Earthquake Earthquake Contact Grade 1


EQ2 Earthquake Contact Grade 2
EQS Earth Quake Switch
EQW Earthquake Counterweight Switch
EQR Earthquake Reset Switch

ISS OCSS Independent Service Switch


^ISS rear Independent Service Switch
ISP Independent Service Parking switch
PDD Partition Door Device switch
FAN Fan
^FAN rear Fan
HFA Handicapped COP Fan
CTL Car To Lobby
CTC CTLPC Car To Landing Park with doors Closed switch
CTO CTLPO Car To Landing Park with doors Open switch
PKS ParKing Switch
PKG PKS Group switch
CFB RSL Car FeedBack
IST Intermittent Stop switch
ROT Riot OperaTion
ACC Anti Crime Car switch
ACH Anti Crime Hall switch
GSI Group Successive Starting In

COC Cut/Disable Car-call cut Off (Car)


COH Car-call cut Off (Hall)
HCO Hall-call Cut Off
HCH Hall Call Cut off from Car
GCO hall call Cut Off (Group)
CHC Cut Hall Call switch latch
DFD Disable Front Door
DRD Disable Rear Door
GCB General Control Button
^GCB Rear General Control Button
CRC Card Reader Contact
BOS BOSs card reader overwrite
LDS Lobby Door Open Switch
MAS Maintenance Access Switch
HCR Hall Call Card Reader

ATK Attendant Attendant Key switch


ATU Attendant key Up

Copyright © OTIS Elevator Company


OTIS - OEC CUSTOMER SERVICE TOOL Dwg : GAA25NC
Date : 2007-10-26
ENGINEERING CENTER
BERLIN GECB Page : 12/23

FSM Owners Information Manual

Input Group Description


ATD Attendant key Down
NSB Non Stop Button
RB Reset Button
^RB rear Reset Button

GRT Group Group Riot


DPC Down Peak Clock
UPC Up Peak Clock
DUP Dual Up Peak Clock
SRO Separate Riser Operation Switch
AD1 Alternate Dispatch floor key switch 1
AD2 Alternate Dispatch floor key switch 2
AD3 Alternate Dispatch floor key switch 3
BPZ Parking Zone
ELZ Parking Zone
GFB Group link Feedback input
WCO Wild Car Operation switch
SG1 Split Group operation key switch 1
SG2 Split Group operation key switch 2
SG3 Split Group operation key switch 3
SG4 Split Group operation key switch 4
SG5 Split Group operation key switch 5
SG6 Split Group operation key switch 6
SG7 Split Group operation key switch 7

CS1 Secure Access Car Secure access button 1


CS2 Car Secure access button 2
CS3 Car Secure access button 3
CS4 Car Secure access button 4
CS5 Car Secure access button 5
CS6 Car Secure access button 6
CSC Car Secure access Clear switch
CSK Car Secure access Keyswitch
GSK Group Secure access Keyswitch

CLR REM Car Light Relay


DFO Door Fully Opened
^DFO Rear Door Fully Opened
LEV Level Signal for REM

DCD Russian Code Disable Call and Door switch


CCB Car Call to Bottom landing
CCT Car Call to Top landing

PC1 Simplex Park Car Clock 1

Copyright © OTIS Elevator Company


OTIS - OEC CUSTOMER SERVICE TOOL Dwg : GAA25NC
Date : 2007-10-26
ENGINEERING CENTER
BERLIN GECB Page : 13/23

FSM Owners Information Manual

Input Group Description


PC2 Park Car Clock 2
PC3 Park Car Clock 3
PC4 Park Car Clock 4
PC5 Park Car Clock 5
PC6 Park Car Clock 6
PC7 Park Car Clock 7
PC8 Park Car Clock 8

SHC Shabbat Shabat Operation Switch


SHT Shabat Operation Timer

AMC Miscellanious AM Clock input


LPT Landing Passing Tone
SMB Speech Message Board Busy

Copyright © OTIS Elevator Company


OTIS - OEC CUSTOMER SERVICE TOOL Dwg : GAA25NC
Date : 2007-10-26
ENGINEERING CENTER
BERLIN GECB Page : 14/23

FSM Owners Information Manual

5 Status Outputs Menu

5.1 System outputs


Output Group Description
1RT Tripping Remote Tripping for car
1RR Remote Resetting for car
3RT Remote Tripping for counterweigt

LVC Door Bypass LVC-Relay


SFR Safe To Relevel (door bypass active and no demand to run)

DFR OCSS DFC-Relay


PDR Power Down Relay (Power Save Mode)
LR Light Relay
UD Up / Down (e.g. trip counter)

Copyright © OTIS Elevator Company


OTIS - OEC CUSTOMER SERVICE TOOL Dwg : GAA25NC
Date : 2007-10-26
ENGINEERING CENTER
BERLIN GECB Page : 15/23

FSM Owners Information Manual

Output Group Description


NUD Emergency
NUG

BUT REM BUTton operated (any demand to move)


DO Door fully Opened
NORM NORMal operation (no faults)
CPR Car PaRked, waiting for demand

MF Main Floor (lobby)


LND LaNDing passing
OOS Out Of Service
LEV LEVel signal

DC Door Close Command


RFS Request For Service
SPB Service Panel Board Fault
SCS Slack Belt Contact Switch

HTS Hall Temperature Sensor on SPB


RDO Rear Door Open Signal
RDC Rear Door Close Signal

BRK Brake Signal from Drive


SAF Safety Chain (ES)
DS Door Switch (with DBP: DW, w/o DBP: DFC)
CLM Car Light Monitoring

DOP Door Open Sensor


^ROP Rear Door Open Sensor

Copyright © OTIS Elevator Company


OTIS - OEC CUSTOMER SERVICE TOOL Dwg : GAA25NC
Date : 2007-10-26
ENGINEERING CENTER
BERLIN GECB Page : 16/23

FSM Owners Information Manual

6 Test Events Menu

6.1 View Events

Copyright © OTIS Elevator Company


OTIS - OEC CUSTOMER SERVICE TOOL Dwg : GAA25NC
Date : 2007-10-26
ENGINEERING CENTER
BERLIN GECB Page : 17/23

FSM Owners Information Manual

R 6.2 Erase Events

Copyright © OTIS Elevator Company


OTIS - OEC CUSTOMER SERVICE TOOL Dwg : GAA25NC
Date : 2007-10-26
ENGINEERING CENTER
BERLIN GECB Page : 18/23

FSM Owners Information Manual

7 Test Selftest Menu

Copyright © OTIS Elevator Company


OTIS - OEC CUSTOMER SERVICE TOOL Dwg : GAA25NC
Date : 2007-10-26
ENGINEERING CENTER
BERLIN GECB Page : 19/23

FSM Owners Information Manual

8 Info messages

Info Message Comment


OVF-WW CAN-Comm Controller Type and Drive Type
Operat: FCL > used Operation Mode
DCL >
SAPB-IL >
FCL-DU >
FCL-SB >
DCL+BSM >
DBP : yes > Door Bypass enabled?
no >
RSL’s: 1 > Number of RSL links.
3 >

Copyright © OTIS Elevator Company


OTIS - OEC CUSTOMER SERVICE TOOL Dwg : GAA25NC
Date : 2007-10-26
ENGINEERING CENTER
BERLIN GECB Page : 20/23

FSM Owners Information Manual

9 Appendix

9.1 Event Logging


Classes
I Info
W Warning
F Fault

event class reason


total runs total number of runs since last power on
minutes on minutes since last power on
0000 Task Timing W Dummy task has not been called within timeout. Software has
been restarted.
0001 S/W Reset W Watchdog circuit on GECB was triggered. Software has been
restarted.
0002 Illegal Int W illegal interrupt was executed
0003 CanTxFull W CAN messages cannot be sent
0004 CanBusOff W CAN communication has been restarted
0006 StackCheck F Stack Violation was detected. Software has been restarted.
0007 SCN Error F Wrong Software.
 order a new software with correct part number.
0008 TimerSync F Internal software timers have not been updated correctly.
Software has been restarted.
0009 Task Fail F Application software doesn't run properly. Software has been
restarted.
0010 McbCommErr F No CAN connection to the drive
0011 SpbCommErr W No CAN connection to the SPB
0012 Power On I Board has been powered on.
0013 Event Fail W
0014 PowerOffOn I Short Failure of Power Supply.
0016 S/W Restart W Reset with unknown reason
0017 Trace Error F bad value in the event Trace Control buffer
0019 MissedLvInt F lv1 and lv2 edge was missed
0100 OpMode NAV F OCSS is not available due to drive fault (e.g. drive-fault (NR).
This mode is also active after INS before the COR starts
0101 EPO shutd. W The car is not able to run during EPO (e.g. because it is
switched to ERO); the next car is allowed to recover.
0102 OpMode DTC W door was not able to close (missing DCL, DFC or DW) within
timeout
0103 OpMode DTO F door was not able to open (missing DOL) within timeout
0104 OpMode DCP W car was not able to answer a call within timeout (e.g. door was
held open manually)
0106 PDS active I partition door switch is opened

Copyright © OTIS Elevator Company


OTIS - OEC CUSTOMER SERVICE TOOL Dwg : GAA25NC
Date : 2007-10-26
ENGINEERING CENTER
BERLIN GECB Page : 21/23

FSM Owners Information Manual

event class reason


0107 DS bypass F Malfunction of Disable Door Switch Relays (DDSR) for Generic
Firemen Service.
0108 EEC bypass F Malfunction of Disable Emergency Exit Contact Relay
(DEMERC) for Generic Firemen Service.
0109 Stuck DCB F Door Close Button contact permanent active

0110 Stuck RDCB F Rear Door Close Button contact permanent active

0201 Correct.Run I A correction run was performed (e.g. after INS, NAV)
0202 /ES in FR W ES-input was activated during Fast Run
0203 /ES in SR W ES-input was activated during Slow Run
0204 TCI/ERO on I TCI or ERO has been switched on
0205 SE-Fault F The car cannot start due to missing SE-signal
 Check the door bypass
0210 /DZ in NST F DZ-signal was lost or not detected at all after having stopped
0211 /DFC in FR W car door has been opened during Fast Run
0212 /DFC in SR W car door has been opened during Slow Run
0213 DrvPrepErr W Prepare To Run expected from Drive
(e.g. missing load weighing information for ABL)
0214 DrvStuckPtr W Drive stuck in Prepare To Run
0215 DrvStuckRtr W Drive stuck in Ready To Run (No Abl)
0216 DrvBrakeErr F Brake not lifted.
0217 DrvCreepErr F Drive Creep time too long.
0218 DrvShutdown F The drive reports a Shutdown
 See event logging of MCB.
0219 DrvStartErr F
0220 DrvService W The drive requested “Request For Service” (REM). See drive
event logging for reason.
0222 1TH-Fault W The DBR-contact which is connected to the input 1TH is
opened. The drive is powered down to allow cooling.
0223 2TH-Fault F One of the contacts which is connected to the 2TH is opened.
0224 DrvEndRun F Drive did not end the run.
0225 110VAC dead F 110VAC is dead for 5 seconds
0228 1LS+2LS on F Limit switches 1LS and 2LS are active at the same time.
 Check power supply of the position reference system.
0230 RSL Adr Chk F Some RSL I/Os have to be programmed to a valid address and
are not allowed to be set to 00-0 or 01-0. Currently only one I/O
is checked:
691 – TCI
 Set I/O 691 to a valid address
0233 PowerSave I The drive package has been powered on
0237 /DW in FR W landing door has been opened during Fast Run
0238 /DW in SR W landing door has been opened during Slow Run
0300 DBP: dfc_SE F While the door was opening or fully opened, the door bypass
was found to be inactive (DFC low or SE high)
0301 DCL in [ ] F (R)DCL was active while the door was fully opened

Copyright © OTIS Elevator Company


OTIS - OEC CUSTOMER SERVICE TOOL Dwg : GAA25NC
Date : 2007-10-26
ENGINEERING CENTER
BERLIN GECB Page : 22/23

FSM Owners Information Manual

event class reason


0302 DoorBridge F DW or DFC was not low during the last door cycle, that means
that the safety chain is bridged or the Door Bypass is defect.
0304 DOL:alw. on F DOL was active while the door was fully closed. This event is
also logged when the fuses of the door system are burned.

This event is not logged within the first 40 seconds after system
startup.
0306 Hwy Access F Landing Door was opened or the car door is bridged.
 see description for blinking message 'Switch INS'
0307 RDOL:alw.on F RDOL was active while the door was fully closed. This event is
also logged when the fuses of the door system are burned.

This event is not logged within the first 40 seconds after system
startup.
0308 DOOR sync F Multidrop synchronization error
0309 DOOR adr. F Multidrop unused message origin
0310 FDOOR chk F Multidrop front door checksum error
0311 RDOOR chk F Multidrop rear door checksum error
0312 FDOOR reply F Multidrop front door communication timeout (>200ms)
0313 RDOOR reply F Multidrop rear door communication timeout (>200ms)
0314 GDS noPull F GDS relay not pulled
0315 GDS noDrop F GDS relay not dropped
0319 GSM Error F GSM input error
0400 RSL parity W Two remote stations with the same address are connected to
the same link
0401 RSL sync W Synchronization lost on remote serial link.
 Check whether there is a shortcut on the link.
0402 RSL reinit F RSL driver has reported a problem. RSL was reinitialized.
0403 RSL Fail F Application has detected that the RSL driver doesn't run
anymore. Software has been restarted.
0404 RSL Hrtbeat F RSL driver has detected that the application doesn't run
anymore. Software has been restarted.
0405 RSL Board F RSL board mismatch!
0406 Group RSL F Group RSL has failed
0500 RNG1 msg W data error on Duplex/Triplex ring
0501 RNG1 time W no ring messages received from other car for a specific time
0502 RNG1 sio W framing error on Duplex/Triplex ring
0503 RNG1 tx W ring messages couldn't be sent in an appropriate time
0504 RNG1 rxOff W No messages are received within a timeout, and NO BREAK is
detected.
0505 RNG1 reset W Reinitializing RING Service (stm_ring_run expired)
0506 DES offline F DES is not present
0507 GCB offline F no GCB is present

Copyright © OTIS Elevator Company


OTIS - OEC CUSTOMER SERVICE TOOL Dwg : GAA25NC
Date : 2007-10-26
ENGINEERING CENTER
BERLIN GECB Page : 23/23

FSM Owners Information Manual

event class reason


0600 SPB-Alert W The Service Panel Board detected a malfunction, which hinders
a manual rescue operation with SPB and SDI. Possible reasons
are:
- defective speed encoders for SDI
- defective E2PROM on SPB
- Missing battery for SPB
Press the SPB-buttons REB + DDO simultaneously to locate
the error.
0601 SPB:TempHTS W The Service Panel Board detected an over temperature.
0602 LwssService W The LWSS requested “Request For Service” (REM).
See LWSS event logging for reason.
0604 S/W Changed I SCN changed
0605 Update S/W! F NumEventGroups, eventGroup or event outside range

Copyright © OTIS Elevator Company