Académique Documents
Professionnel Documents
Culture Documents
Qty 1 1
Line Size 6” 6”
Size of required Control Valve 4” 4”
Line Pressure 1021 PSI 605 PSI
Line Temperature 58 Deg C 42 Deg C
Min 88 bbl/d Main 52 bbl/d
Oil Flow Rate
Max 298 bbl/d Max 201 bbl/d
Approx. Oil Gravity 991 Kg/m3 991 Kg/m3
Min 4 MMSCFD Min 2 MMSCFD
Gas Flow Rate
Max 13.040 MMSCFD Max 8.380 MMSCFD
End Connection Style RTJ RTJ
Flange Rating 900 Class 900 Class
Valve Body Material Vendor to Advice Vendor to Advice
Trim Material Vendor to Advice Vendor to Advice
Actuator Type / Size Pneumatic Pneumatic
Actuator Supply Vendor to Advice Vendor to Advice
Actuator Action Air Fail to Close Air Fail to Close
I/P DVC 6000 I/P DVC 6000
Positioner Type 4 – 20 mA Input 4 – 20 mA Input
Hart Compliant Hart Compliant
SOV None None
Ex Rating Class-I, Div-2 Class-I, Div-2
Ambient Temp Max 50 Deg C Max 50 Deg C
Outlet pressure or Differential Up stream of controller pressure ranges 2200 to 200 psi and
pressure across the control valve downstream pressure ranges 1100 to 200 psi.
(3) Ideal Gross Heating Value (3) Ideal Gross Heating Value
1239.3 BTU.ft-3 at 14.73 psia 1249.4 BTU.ft-3 at 14.73 psia and
and 60°F 60°F
Real Gross Heating Value
Real Gross Heating Value 1253.9
1243.7 BTU.ft-3 at 14.73 psia
BTU.ft-3 at 14.73 psia and 60°F
and 60°F