H V A C S y s t e m s M o n i t o r i n g

SSK451 Multi-Signaling
Accessory
Models Available
SSK451
SSK451
Optional Accessories Available
PS24LOW Strobe
PS12/24SLENSW “SMOKE” Lens

Product Overview

Key-activated test and reset functions

Sounder horn can be wired for periodic or


temporal tone

Power (green), trouble (amber) and


alarm (red) LEDs

Installs to a double-gang electrical box

Optional PS24LOW strobe and PS12/


24SLENSW “SMOKE” lens can be easily
added for visual alarm signaling to meet
special code requirements in
certain jurisdictions
SSK451 with PS24LOW Strobe and PS12/24SLENSW “smoke” lens
Compatible with all System Sensor
DH100ACDC and DH400ACDC duct
smoke detectors

The System Sensor SSK451 multi-


signaling accessory is designed for
use with System Sensor DH100ACDC
and DH400ACDC duct smoke
detector models and combines a horn
feature with the key-activated test and
reset functions. Green, amber and
red LEDs provide visual indication of
power, trouble and alarm conditions,
respectively.

S2522
General Specifications
Dimensions Power Requirements Temperature
4.8″ W × 4.7″ H × 1.5″ D Standby: 5 mA max. 14° F to 140° F (–10° C to 60° C)
(12.2cm W × 11.9cm H × 3.8cm D Trouble: 9 mA max.
Alarm: 30 mA max. Humidity Range
Weight 95% RH, noncondensing
0.35 lb. (160 g) Connections
Strip terminal, 14 AWG to 22 AWG wire Listing
Operating Voltage UL 268A
15–35 VDC Sounder
87 dBA minimum at ten feet

SSK451 with Innovair™ DH100ACDC Duct Smoke Detector Wiring Diagram


FIELD INSTALLED
JUMPER FOR
TEMPORAL PATTERN

COMMON 3
TEMPORAL SELECT 2 15 ALARM SIGNAL
ALARM SIGNAL 1 3 SUPERVISORY
NO CONTACT
SUPERVISORY SIGNAL 4 14
RESET 7 2 RESET
TEST 8 11 TEST
POWER (–) 6 20 AUX. POWER (–)
POWER (+) 5 19 AUX. POWER (+)

SSK451 DH100ACDC

FIELD INSTALLED
JUMPER

SSK451 with DH400ACDC Duct Smoke Detector Wiring Diagram and Test Coil Installation

FIELD INSTALLED Note: When the SSK451 is used with a DH400ACDC duct smoke
JUMPER FOR detector, a test coil, par t number COIL, must be ordered sepa-
TEMPORAL PATTERN rately. When the SSK451 is used with a DH100ACDC duct smoke
detector, a test coil is not required. The COIL is installed in the
DH400ACDC duct smoke detector housing as shown below.
COMMON 3
TEMPORAL SELECT 2 5 ALARM SIGNAL
ALARM SIGNAL 1 10 SUPERVISORY
NO
SUPERVISORY SIGNAL 4 11 CONTACT TEST COIL

RESET 7 3 RESET
DETECTOR
TEST 8 4 TEST HEAD

POWER (–) 6 6 AUX. POWER (–)


POWER (+) 5 7 AUX. POWER (+)

SSK451 DH400ACDC

FIELD INSTALLED
JUMPER

System Sensor Sales and Service


System Sensor Headquarters System Sensor Canada System Sensor in China System Sensor – Far East System Sensor – India
3825 Ohio Avenue Ph: 905.812.0767 Ph: 86.29.8832.0119 Ph: 85.22.191.9003 Ph: 91.124.637.1770 x.2700
St. Charles, IL 60174 Fx: 905.812.0771 Fx: 86.29.8832.5110 Fx: 85.22.736.6580 Fx: 91.124.637.3118
Ph: 800/SENSOR2 System Sensor Europe System Sensor in Singapore System Sensor – Australia System Sensor – Russia
Fx: 630/377-6495 Ph: 44.1403.891920 Ph: 65.6273.2230 Ph: 613.54.281.142 Ph: 70.95.937.7982
www.systemsensor.com Fx: 44.1403.891921 Fx: 65.6273.2610 Fx: 613.54.281.172 Fx: 70.95.937.7983