Vous êtes sur la page 1sur 6

CURRICULUM VITAE

Personel mob: +919443018533 / +917028025667.

Page 1 of 6
Objective:
SARAVANAKUMAR.A

Date of Birth : 07-06-1983 Professional carrier in your concern which offers continuous
Nationality : Indian
Sex : Male development opportunity and to draw satisfaction from
Marital Status : Married personnel and organization growth.
Blood Group : B +ve

Languages Known: Professional Details:


English, Tamil and Hindi
Professional Qualification:
Passport Details:
Passport No. : P7346371. Bachelor of Electrical and Electronics Engineering.
Valid up to : 15.02.2027.
Issued at : Chennai. Institute : Arulmigu Meenakshi Amman College of
engineering.
Permanent Address:
No : 160 / 1, T.K.M.Road, University : Madras University
Vallam Post,
Chengalpattu.
Tamil Nadu-603 002. India. Year of completion : 2004.
Mobile- Res : +919443018533.
+917028025667.
HIGHLIGHTS:
Present Company:
M/S. Dhawin Engineering
Chennai Electrical Engineer. – Carrying the job to the customer’s standed with safety and
Sr.Testing and Commsisioning. initiative’s creativity, communication & achieving the work at
stipulate time.
Previous Company:

1. M/s.Larson And Toubro LTD. Experience:


(Jan 2012 to Oct 2016)
Having around 13.0 Years of experience and knowledge in the
2. M/s.Sterling and Wilson Ltd.
field of Substation Equipment Testing & Commissioning,
(Nov 2009 to Jan 2012)
Protective Relays, and Maintenance of Switchyards, Power
3. M/s.SSEngineering – Sr.T&C Transformers, process plant, power plants and Co-ordination of
Engineer. Erection work and SCADA.
(March 2008 to Oct 2009)
4. M/s.Voltech Engineers Pvt Ltd. Graduate Traine:
(March 2006 to Jan 2008)
Tamil Nadu Eletricity Board (TNEB) – 230KV,110KV
5. TNEB – 230KV/110KV SS Substation Grid Relay Testing (GRT).
(GRT) Graduate Apprentice
Trainee. (March 2005 to Feb 2006)

PERSONAL DETAILS:- e-mail : sakumarcpt07@gmail.com

RESPONSIBILITIES IN EXECUTION OF PROJECTS :-

 Testing & Commissioning of Electrical Equipments (Switchyard - PowerTransformers, PT, CT,


CB, Disconnectors, Earth switches and Protective Relays).

 Scheme checks and Relay co-ordination as per specification.

Page 2 of 6
 Preparation of safety documents and method of statements for outages.

 Preparation of As built drawings, cable schedule and Site acceptance test records according to
the specifications.

 Trouble shooting of all Electrical control and protection circuits.

 BUS Transfer (BTS) System Testing and Commissioning.

 Co-ordination with Erection Team and Transformer and Lighting Panels.

NATURE OF WORK :-

 Testing and commissioning of all Electrical equipment from 415volts Systems and 230KV &
400KV Substation.

 Testing, Diff Stability and REF Stability of Power Transformer (270MVA).

 Co-ordination with Erection Team for Transformer and Panel Erections.

 Testing and commissioning of L.T, MV, H.T Switchgears, Switchyard (CT, CVT, CB, Busbar,
Disconnector, Earth switch).

 Testing and commissioning of Control & Protection panel and Protective Relays (Numerical-
Areva, ABB, Siemens and, Electromagnetic)

 Transformer, and Motor Protection relays (Differential, Over current & Earth fault, REF and
Stability and schemes .

 Inspection of control and relay panel, preparation of Test Report, cable schedule, As built
Drawings, Method of statement for shutdown jobs and Operation & Maintenance for sub-station,
power plant, and process plant.

PRESENT PROJECTS :-

1. Magagenco Thermal Power Project 3x660MW Tpp – Koradi.


 400KV Switch yard Equipment testing and commissioning.

 Testing & commissioning of 11KV / 3.3KV / 0.433KV Switch gear Panels (500 Panel – C&S),
Transformers (2.5MVA), Areva Relays, Protection Schematic and Operations.

 Co-ordination with Erection Team for Transformer and Panel Erections.

 Preparation of contract completion documents for technical support.

 Preparation of Method of statement and safety document to the outages.

 Preparation of As built drawings and cable schedules for approvel.

 270MVA G.T – Testing and Commissioning work.

 63MVA ST – Testing and Commissioning work.

 20MVA UAT – Testing and commissioning work.

Page 3 of 6
 BUS Transfer (BTS) System Testing and Commissioning.

2. Indiabulls Thermal Power Project 5x270MW Tpp – Nashik.


 400KV Switch yard Equipment testing and commissioning.

 Testing & commissioning of 6.6KV / 0.433KV Switch gear Panels (300 Panel – L&T),
Transformers (2.5MVA), L&T Relays, Protection Schematic and Operations,

 Preparation of contract completion documents for technical support.

 Preparation of Method of statement and safety document to the outages.

 Preparation of As built drawings and cable schedules for approvel.

 270MVA G.T – Testing and Commissioning work.

 63MVA ST – Testing and Commissioning work.

 20MVA UAT – Testing and commissioning work.

 BUS Transfer (BTS) System Testing and Commissioning.

3. Rattan india Thermal Power Project 5x270MW Tpp – Amravati.


 400KV Switch yard Equipment testing and commissioning.

 Testing & commissioning of 6.6KV / 0.433KV Switch gear Panels (100 Panel – L&T),
Transformers (2.5MVA), L&T Relays, Protection Schematic and Operations.

 Co-ordination with Erection Team for Transformer and Panel Erections.

 Preparation of contract completion documents for technical support.

 Preparation of Method of statement and safety document to the outages.

 Preparation of As built drawings and cable schedules for approvel.

 270MVA G.T – Testing and Commissioning work.

 63MVA ST – Testing and Commissioning work.

 20MVA UAT – Testing and commissioning work.

 BUS Transfer (BTS) System Testing and Commissioning.

4. RAMANUJAR IT PARK.
Client : Alliance 1st. Projects : for EIL.

 110KV Switch yard Equipment testing and commissioning.

 Testing & commissioning of 11KV / 0.433KV Switch gear Panels (4 Panel – Siemens),
Transformers (2.5MVA), L&T Relays, Protection Schematic and Operations,

 Preparation of contract completion documents for technical support.

 Preparation of Method of statement and safety document to the outages.

 Preparation of As built drawings and cable schedules for approvel.

5. CHEYYAR SEZ DEVELOPERS.


Client : CSD. Projects : for EIL.

Page 4 of 6
 Testing & commissioning of 11KV / 0.433KV Switch gear Panels (3 Panel – Siemens),
Transformers (2.5MVA), AREVA Relays, Protection Schematic and Operations,

 Preparation of contract completion documents for technical support.

 Preparation of Method of statement and safety document to the outages.

 Preparation of As built drawings and cable schedules for approvel.

6. ISRO - THIRUVANDRAM.
Client : ISRO - SPCL. Projects : for EIL.

 Testing & commissioning of 11KV / 0.433KV Switch gear, Transformers (2.5MVA), AREVA, E.R
Relays, Protection Schematic and Operations of Panels Phase -1,

 Preparation of Method of statement and safety document to the outages.

 Preparation of As built drawings and cable schedules for approvel.

INTERNATIONAL ASSIGNMENT

OIL AND GAS :-


1. QATAR GAS.
Client : QATAR Electricity Board.
Projects : QATAR GAS - Raslaffan.

Testing and commissioning of 0.433KV Breaker (OC/ EF) Protection Siemens Relay. –
QATAR.

DOMESTIC ASSIGNMENT

OIL AND GAS :-

 Testing and commissioning of 11KV / 0.433KV SWITCH GEAR, for 2.5MVA, 11KV 12MW
SW Generator.Cordination with relay engineer for testing of ABB relays and Woodward
Relays.

 Testing and commissioning of 0.433KV, 11KV SWITCH GEAR, 2.5 MVA Transformer.Cordination
with relay engineer for testing of Relays.

POWER PLANT , SWITCHYARD, PROCESS PLANTS & SUB STATIONS :-

 Testing and commissioning of 33KV AND 11KV SWITCH YARD , 50MVATransformers,


OLTC operation, Auxiliary protections, Differential & REF Stability, Control & Relay panel
Schemes,Relays (SIEMENS). COCHIN SHIP YARD thro Siemens.

 Testing and commissioning of 11KV SWITCH YARD, 50MVA Transformers, OLTC operation,
Auxiliary protections, Differential & REF Stability, Control & protection Schemes,
Relays(ABB, Siemens).Motorla thro GET .

Page 5 of 6
 Testing and commissioning of 132/11 KV/0.433KV SWITCH YARD, 50MVA Transformers ,
OLTC operation, Auxiliary protections, Differential & REF Stability, Control & Relay panel
Schemes,(ER Relays). PGCL – YANAM (A.P).

 Testing and commissioning of 0.433KV and 11kv Switchgear, Stability for Transformer
2.5MVA, Auxiliary protections, Control & protection Schemes, Relays(ABB). RAYALSEMA
Thermal power plant – RAYALSEMA – A.P thro ABB .

 Testing and commissioning of 400KV/ 6.6KV G.T & S.T Transformer Commissioning and
6.6KV & 415V Switchgear, Stability for Transformer 2.5MVA, Auxiliary protections, Control
& protection Schemes, Relays(ABB). Indiabulls Thermal power plant – Amravati & Nasik .

Experience with AREVA RELAYS

MiCOM P630 - Transformer Protection


MiCOM P120,P121,P111,P123 - O/C & E/F Protection
MiCOM P225 - Motor protection

Experience with ABB Relays

SPAJ 140C - O/C & E/F Protection.


SPAJ 115C - SEF and REF.

SEL Relay 751A - O/C & E/F Protection.

Experience with SIEMENS Relays

7SJ6005, 7SJ6225 - O/C & E/F Protection.


7UT612 - Transofrmer Diff.Protection.
7SJ62,63,64 - Multi function Relay.

Regards,
SARAVANAKUMAR.A

Page 6 of 6