Académique Documents
Professionnel Documents
Culture Documents
EXISTING ROOF
EXISTING ROOF
NEW ROOF LIGHT BOUNDARY
SVP SVP EX SVP LINE
OPEN - REMOVE EXIST.
SVP LEAN-TO ROOF
RWP
EXIST. ROOF
RWP RWP
RWP REMOVE EXIST. DOOR
NEW WINDOW
RWP Vv
NEW BALUSTRADE RE-MOVE STAIRS
KITCHEN
NEW SOIL
STACK RE-MOVE STAIRS
RWP
RW
RE2 BINS STORAGE
G STUB
BOUNDARY RE 1 STACK dia.100 RE 2
MOVE EX GULLY LINE
EXISTG SOIL DRAIN
SOUTH ELEVATION
- SCALE = 1:100 SECTION A-A
- SCALE = 1:100 - SCALE = 1:100
AREAS
EXISTING ROOF
AWNINGS REMOVED
NEW WINDOWS
SVP & DOOR TO MATCH EXIST.
NEW DOOR
Vv Vv
BOUNDARY
LINE REMOVE EXIST.
BALCONY WALL 1. WALLS IN FOOD PREP. AREAS TO BE TILED TO 2,0M HIGH.
CUT VERT. JOINT
A NEW FIRE
A 2. DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS ONLY.
3. ALL DIMENSIONS ARE, UNLESS OTHERWISE SPECIFIED, MEASURED IN
MILLIMETERS.
ESCAPE STAIRS 4. ALL DIMENSIONS, ANGLES AND LEVELS TO CHECKED ON SITE AND ANY
DISCREPANCIES ARE TO BE REPORTED TO THE ARCHITECT PRIOR TO
THE COMMENCEMENT OF WORK.
BIN AREA
G EX SVP
UP - 5. ENTIRE STRUCTURE TO ENGINEERS DETAILS AND APPROVAL
rwp 6. ALL BUILDING WORK IS TO COMPLY WITH SANS 0400 AND LOCAL
MUNICIPAL BY-LAWS.
7 ALL BEAMS TO RC DETAILS TO ENGINEERS DESIGN/DETAILS
8. PLUMBER TO EXPOSE & CHECK LEVELS OF EXISTING SEWER PRIOR
ROOF LIGHT
4 5 OVER 17
TO COMMENCEMENT OF WORKS.
ARCHITECT
6 15 9. ALL GLAZING THICKNESS TO COMPLY WITH SANS 10400 SCALES AS SHOWN
KITCHEN PART NN2. DATE JULY 2013
pot sink 10. ALL SAFETY GLAZING IN ACCORDANCE WITH SANS 10400
NN3. DRAWING NO. HA 02-05-13/1
EXISTG SOIL DRAIN
7 16 P.O.Box 37605
18 Overport
4067
3 DINING GARDEN 14
1.1 ARTIFICIAL LIGHTING & VENTILATION - INTERNAL BATHROOMS Telephone 031 309 1515
ALL AREAS TO COMPLY WITH SANS 10400 PART O Telefax 031 309 1562
AIR TO BE EXTRACTED AT 20L /SECOND/FITMENT e-mail:howellarchitects@mwebbiz.co.za
ARTIFICIAL LIGHTING :BATHROOMS 160LUX
Reg. No. 5418
MILLIMETERS.
OF
LANE 4 572 WIDE
RE
4. ALL DIMENSIONS, ANGLES AND LEVELS TO CHECKED ON SITE AND ANY
11 10 SVP
22 DISCREPANCIES ARE TO BE REPORTED TO THE ARCHITECT PRIOR TO
13 21 THE COMMENCEMENT OF WORK. INTERNAL ALTERATIONS
2 5. ENTIRE STRUCTURE TO ENGINEERS DETAILS AND APPROVAL
6. ALL BUILDING WORK IS TO COMPLY WITH SANS 0400 AND LOCAL
MUNICIPAL BY-LAWS.
TO EXISTING HOTEL AT
9 20
7 ALL BEAMS TO RC DETAILS TO ENGINEERS DESIGN/DETAILS
8. PLUMBER TO EXPOSE & CHECK LEVELS OF EXISTING SEWER PRIOR
226 NINTH AVE. MORNINGSIDE.
TO COMMENCEMENT OF WORKS.
9. ALL GLAZING THICKNESS TO COMPLY WITH SANS 10400 (SUB 1 OF LOT 852 DURBAN)
VERANDAH PART NN2.
1 VERANDAH
ENTRY 10. ALL SAFETY GLAZING IN ACCORDANCE WITH SANS 10400 FOR
12 NN3.
PUBLIC SAFETY: ALL BALUSTRADING TO BE MINIMUM 1 DOUBLE STAR TRADING
METER HIGH AND TO COMPLY WITH THE REQUIREMENTS OF
DD2 OF SANS 10400.
11. ALL STAIRS TO COMPLY WITH PART M OF OF SANS 10400.
172 CC
A EXTEND WALL GL 101.90
A 12. GLAZING TO COMPLY WITH SANS 10400 PART N
TO MATCH EXISTG
SITE/GROUND FLOOR PLAN SIDEWALK 1ST FLOOR PLAN FLOOR PLANS,SITE PLAN ELEVATIONS,
SCALE = 1:100 ELP
SCALE = 1:100
N NINTH AVENUE 12 200 WIDE N SECTIONS, NOTES