ELE
International
Operating Instructions
TRI-FLEX 2
TRIAXIAL TEST SYSTEMF, CALCULATIONS....... 32
G. DRAINING SYSTEM... - . 33
CHAPTER V - TRIAXIAL TEST . 35
A. INTRODUCTION....... 35
B. EQUIPMENT SET-UP. . 36
C. INSTALLATION OF SPECIMEN AND CELL... 36
D. _DE-AIRED WATER TANK SYSTEM.......... cecenreneees 37
E. _ FILLING AND DE-AIRING THE BURETTE CHANNELS... sons 37
F, FILLING THE CELL AND APPLYING CELL PRESSURE «...cc.ssscsste 37
G, PURGING AIR FROM POROUS STONES AND CELL LINES 37
H. SPECIMEN SATURATION ..
Initial Specimen Saturation using Vacuum.
Saturation using Back Pressure
PORE PRESSURE MEASUREMENT .....
VOLUME CHANGE MEASUREMENT.
PRE-CONSOLIDATION see.
FINAL TRIAXIAL TEST PROCEDURE
Q Test (Unconsolidated Undrained or UU Test) .
R Test (Consolidated Undrained or CU test)..
S Test (Consolidated Drained or CD Test)
rRee
CHAPTER VI - CALIBRATION AND MAINTENANCE rivireisisesenaneminnstencsste 42
A. Pressure Meter. : area
B. — Burette/Annulus Volume...
C. Cleaning the Burette/Annulus -
FIGURE 1 - MASTER CONTROL PANEL,
FIGURE 2 - AUXILIARY CONTROL PANEL. =A
FIGURE 3 - TRIAXIAL TEST CELLieveosncon 13
FIGURE 4 - BACK PANEL CONNECTIONS. 18
FIGURE 5 - BURETTE/ANNULUS ASSEMBLY. 44
APPENDIX A ~ MASTER CONTROL PANEL SCHEMATIC. 45
APPENDIX B ~ AUXILIARY PANEL SCHEMATIC..... 46
APPENDIX C - GENERAL SPECIFICATIONS. 47
APPENDIX D -- DEFINITION OF TERMS ..
Rev.0: 4/96RELATED USER DOCUMENTATION
This manual does not contain all the necessary information on the specific test
procedures. Please refer to ASTM D-2850, 0-4767, or 0-5084 for additional testing
information. Other references include:
“Laboratory Soils Testing," U.S. Army Corps of Engineers, Engineer Manual EM 1110-2-
1906 Washington DC, 1986,
“Saturated Hydraulic Conductivity, Saturated Leachate Conductivity, and Intrinsic
Permeability’ Method 9100, U.S. Environmental Protection Agency.
CUSTOMER SUPPORT
ELE/Soiltest Products Division has technical support services available to help you if you
have a problem setting up or operating your Tri-Flex 2 Triaxial Test System. Contact
cone of the following for technical advice:
1. Your ELE/Soiltest Sales Representative
If you have difficulty, begin by contacting the person who sold you your
Tri-Flex 2 system. Your salesperson is familiar with both your needs and your
ELE/Soiltest equipment and should be able to give you the information you want.
2, ELE/Sciltest Technical Services Department
ELE/Soiltest Products Division has an experienced, well-trained technical
services group available for your questions. Service hours are from 8 am until
4:30 pm (CST), Monday through Friday. The technicians can answer your
questions on topics such as equipment installation, connections, system functions
and general test procedures. Call
USA Toll Free: (800) 323-1242
‘Worldwide: (205) 621-2260
Note: Before you call the technical service group, make sure you first do
the following:
1. Review the appropriate section in this manual for possible answers to your
questions.
2. Review the appropriate test standard (e.g, ASTM) if your question relates
to permeability test procedures.