Académique Documents
Professionnel Documents
Culture Documents
P-
S646 140 PDS 05 0 1 /3
2/4
TECHNIP KT INDIA 005A/B
PDS FOR
STRIPPER BOTTOMS PUMP
(TAG NO: 140-P-005A/B)
FLUID HANDLED
Operating case Start of Run
Fluid circulated Stripper Bottoms (Diesel Product)
Corrosive/erosive agents -
Pumping temperature °C 252
Viscosity (PT) cP 0.25
Vapor pressure (PT) bar abs 8.3
Density (60°F/15°C) kg/m3 846.4
Density (PT) kg/m3 681.5
OPERATING CONDITIONS
Normal flow m3/h 171.9 (3)
Design flow m3/h 189.1 (3)
Suction pressure bar g 7.6
Discharge pressure bar g 11.8
Differential pressure bar 4.2
Differential head m 63
NPSH available m 4.0 (Note-9)
Design hydraulic power kW 22
PUMP
Number and type Centrifugal; 1 Operating + 1 Spare
Assumed efficiency 0.69
Design shaft power (estimated) kW 32
Material (Casing / Trim) Carbon Steel / 12 Cr ( Note-6)
DRIVER
Type operating Electrical
spare Electrical
Rated power (Motor rating) kW 55 (4)
NOTES
General note : Design conditions result from normal operation conditions. The results obtained with these conditions are
adequate for SOR & EOR conditions.
(1) Deleted.
(2) The shut-off pressure shall not exceed15.0 barg.
(3) Indicated flow rates are process requirements excluding any minimum flow. The design flowrate is 110%
of the normal flowrate.
(4) Pump motor to be designed to handle cold diesel during start-up (catalyst pre-wetting) at 100% of the
above normal flowrate. Start up Diesel density=861 Kg/m3.
See Page 3 of 3 For Additional Notes
This document contains confidential proprietary material belonging to Axens North America, Inc. which may only
be made available to personnel or organizations who have signed appropriate secrecy agreements
PROCESS DATA SHEET
Project N° - Unit Doc. type Equipment N° Serial N° Rev. index
CK-140-PR-30-0043
CLIENT NOCL Rev. Date Made by Checked by Page
PMC CB&I LUMMUS 0 6-Jun-09 AKG NHB
Revision
2 Additional Notes :
th
3 (5) Pumps shall confirm to API 610, 10 Edition.
4 (6) Material of construction: S-6.
5 (7) Corrosion allowance for casing : 3 mm.
6 (8) Mechanical seal shall be dual unpressurised. Mechanical seal plans: 23, 52.
7 (9) Available NPSH is based on Stripper bottom elevation of 6 m.
8 (10) Refer P&ID No. CS-140-PR-0017.
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
\\Kt001sf0005\s646\Process\5.0 Coded Document\PDS\3.0 PUMP\140-P-005A_B\[S646-140-PDS-P005-Notes.xls]Notes PD017A12
Property of Technip KT India Ltd. To be returned upon request and used only in reference to contract or proposals of this company.
Reproduction of this print or unauthorised use of patented or patentable features disclosed hereon is prohibited.