Vous êtes sur la page 1sur 4

Page 1/4

Project Unit Doc Code Serial Rev. Page

P-
S646 140 PDS 05 0 1 /3
2/4
TECHNIP KT INDIA 005A/B

OWNER : NAGARJUNA OIL CORPORATION LTD.


PMC : CB&I, LUMMUS
LICENSOR : AXENS, IFP GROUP TECHNOLOGY
FEED CONTRACTOR : TECHNIP KT INDIA LTD.
The present document or drawing is property of TECHNIP KT INDIA LTD. and shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied,
disclosed or used, without its prior written consent, for any purpose and in any way other than that for which it is specifically furnished or outside the extent of the agreed upon right of use.

PROJECT : FEED FOR DIESEL HYDRODESULPHURIZATION UNIT


UNIT : DIESEL HYDRODESULPHURIZATION UNIT
PMC DOCUMENT NO : CK-140-PR-30-0043

PDS FOR
STRIPPER BOTTOMS PUMP
(TAG NO: 140-P-005A/B)

0 06/06/2009 APPROVED FOR DESIGN AKG NHB TT SLSK


REV. DATE STATUS PREPARED BY REVIEWED BY APPROVED BY PM
DOCUMENT REVISIONS
Sections changed in last revision are identified by a line in the right margin
TECHNIP DOC NO: S646-140-PDS-P-005A/B-05-REV0 PAGE 2 OF 3

PUMP PROCESS DATA SHEET


Job Number Unit Type Item Page
Process licensing C450 1400 2PU 140-P-005 A/B 1/1
3/4
Client : NAGARJUNA OIL CORPORATION LIMITED Date By Check By Rev
CUDDALORE, TAMILNADU, INDIA 05/08/09 DRM WEM 0
Unit : DIESEL HYDRODESULFURIZATION UNIT
Service : STRIPPER BOTTOMS PUMP

FLUID HANDLED
Operating case Start of Run
Fluid circulated Stripper Bottoms (Diesel Product)
Corrosive/erosive agents -
Pumping temperature °C 252
Viscosity (PT) cP 0.25
Vapor pressure (PT) bar abs 8.3
Density (60°F/15°C) kg/m3 846.4
Density (PT) kg/m3 681.5

OPERATING CONDITIONS
Normal flow m3/h 171.9 (3)
Design flow m3/h 189.1 (3)
Suction pressure bar g 7.6
Discharge pressure bar g 11.8
Differential pressure bar 4.2
Differential head m 63
NPSH available m 4.0 (Note-9)
Design hydraulic power kW 22

PUMP
Number and type Centrifugal; 1 Operating + 1 Spare
Assumed efficiency 0.69
Design shaft power (estimated) kW 32
Material (Casing / Trim) Carbon Steel / 12 Cr ( Note-6)

DRIVER
Type operating Electrical
spare Electrical
Rated power (Motor rating) kW 55 (4)

NOTES
General note : Design conditions result from normal operation conditions. The results obtained with these conditions are
adequate for SOR & EOR conditions.

(1) Deleted.
(2) The shut-off pressure shall not exceed15.0 barg.
(3) Indicated flow rates are process requirements excluding any minimum flow. The design flowrate is 110%
of the normal flowrate.
(4) Pump motor to be designed to handle cold diesel during start-up (catalyst pre-wetting) at 100% of the
above normal flowrate. Start up Diesel density=861 Kg/m3.
See Page 3 of 3 For Additional Notes

PMC DOC NO : CK-140-PR-30-0043

This document contains confidential proprietary material belonging to Axens North America, Inc. which may only
be made available to personnel or organizations who have signed appropriate secrecy agreements
PROCESS DATA SHEET
Project N° - Unit Doc. type Equipment N° Serial N° Rev. index

S646-140 PDS P-005A/B 05 0


TECHNIP KT INDIA LTD. PMC Doc No,

CK-140-PR-30-0043
CLIENT NOCL Rev. Date Made by Checked by Page
PMC CB&I LUMMUS 0 6-Jun-09 AKG NHB
Revision

LOCATION CUDDALORE, TAMILNADU


CENTRIFUGAL PUMP 4/4
3/3
INDIA
UNIT DHU

2 Additional Notes :
th
3 (5) Pumps shall confirm to API 610, 10 Edition.
4 (6) Material of construction: S-6.
5 (7) Corrosion allowance for casing : 3 mm.
6 (8) Mechanical seal shall be dual unpressurised. Mechanical seal plans: 23, 52.
7 (9) Available NPSH is based on Stripper bottom elevation of 6 m.
8 (10) Refer P&ID No. CS-140-PR-0017.
9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48
\\Kt001sf0005\s646\Process\5.0 Coded Document\PDS\3.0 PUMP\140-P-005A_B\[S646-140-PDS-P005-Notes.xls]Notes PD017A12
Property of Technip KT India Ltd. To be returned upon request and used only in reference to contract or proposals of this company.
Reproduction of this print or unauthorised use of patented or patentable features disclosed hereon is prohibited.

Vous aimerez peut-être aussi