Vous êtes sur la page 1sur 1

NOTES

1. All dimensions to be checked on site and


any discrepancy refered to the architect
12,200 immediately.
2. PV denotes permanent ventilation over
doors and windows as marked on plans
and elevations.
g.t

1 15 3. All R.C. (reinforced concrete) works must

15 x 180 = 2,700
I.C
2 14
3
4
5
13
12
11
be carried out as per structural engineers
g.t
details.
6 10
7 9

8
4. All Drain pipes passing under buildings
I.C
or drive-way are to be encased in 150mm
thick concrete surround.

18,200

18,200
g.t g.t

PROPOSED
I.C 2/5817 5. All Plumbing, water reticulation and
PROJECT I.C I.C
drainage to be left clean and in working
order to the entire satisfactionof M.O.H.
Septic
g.t Tank g.t
I.C I.C 6. D. P. C. to be of approved quality
ACCESS ROAD plastic membrane provided under
all walls.

7. All inspection chambers along drive


-way should have quality heavy duty
covers.
3,900 4,325 3,975
ELEVATION 03 ELEVATION 04 ACCESS ROAD 8. Dry co2 fire extuinguisher to be availabled
N at escape route to C. regulations.
ROOF SPECS
ROOF PITCH 30° decra or
SITE PLAN
equivalent roofing tiles on
scale 1:200
REVISIONS 01 DATE SIGN
50mm x 50mm battens on
75mm x 50mm truses to
S.E details. LOCATION PLAN
scale 1:500

p.v p.v
1 2 3 4 5 6
p.v 4,400 3,400 3,400 3,400 3,400
ROOF SPECS
ROOF PITCH 22.5° decra or equivalent
roofing tiles on 50mm x 50mm battens on
75mm x 50mm truses to S.E details.

2,925

2,925
p.v p.v p.v WINDOW SPECS
prefabricated aluminium casement
windows with permanent ventilation to
BEAM SPECS
door and window schedules to
p.v p.v p.v p.v p.v p.v p.v p.v p.v p.v p.v 300mm x 200mm R.C beam to
architects approval. p.v p.v p.v
S.E details

300
LOUNGE

2,700
900mm high ms railing
p.v Toilet with ms balustrades

2,400
DOOR SPECS
Stack Stone cut Grey prefabricated aluminium casement door with
Mazeras Finish p.v p.v p.v p.v p.v p.v p.v p.v p.v p.v p.v permanent ventilation to door and window
p.v p.v p.v
schedules to architects approval.

300
WINDOW SPECS
LOUNGE

2,700
Toilet prefabricated aluminium casement windows with

2,400
permanent ventilation to door and window

ELEVATION 01 ELEVATION 02
schedules to architects approval.
S-Y

S-Y
p.v p.v p.v p.v p.v p.v p.v p.v p.v p.v p.v
p.v p.v

300
E-3 E-3 p.v R.C FLOOR SLAB SPECS
A B C D A B C D 150mm R.C floor slab to S.E details on

2,700
Toilet 1000G polythene sheet on 25mm blinding on

2,400
3,775 4,450 3,775 3,775 4,450 3,775 approved compacted hardcore filling.

12,200
12,200 G.L FOUNDATION SPECS
200 All R.C foundation & struct.elements to s.e details
200 3,575 200 2,025 2,025 200 3,575 200 200

150

150
200 4,175 200 1,425 1,425 200 4,175 200 on 50mm1:4:8 concrete blinding,hardcore on firm
ground free from loose soil or base. depths to be
200

determined on site by S.E. contractor to


1 1 1 1 excavate,remove &cart away all loose & black
200

1,800 200

200

200

200
shw 1,900 shw cotton soils from below new buildings prior to
200 1,800

shw shw
commencing foundation.
whb whb whb whb
200

wc wc wc wc
ROOM G5 ROOM G6 ROOM F5 ROOM F6
4,400

4,400

4,400

4,400
p.v
p.v
4,200

4,200

4,200
p.v p.v (ceramic tiles ff) 3,675 200 1,028 600 1,000 600 1,022 200 3,575 200
200

(ceramic tiles ff) g.t


900

900

p.v p.v p.v p.v


200 3,575 200 1,028 600 1,000 600 1,022 200 3,575 200 (ceramic tiles ff) Passage
(ceramic tiles ff)
±0.000 +2.700
2,200
1,100

1,100

1 15
p.v 1 15
p.v
15 x 180 = 2,700

15 x 180 = 2,700

p.v p.v
I.C
2 14 2 14
7,600

3 13 3 13

2
4 12

2 2
4 12

2 A B C D
600

600

5 11 5 11

g.t ROOF SPECS


100 2,200 200

200

200

200
6 10 6 10

ROOF PITCH 22.5° decra or equivalent


7 9 7 9

ROOM F7
1,100

1,100

p.v p.v
ROOM G4
p.v
ROOM G7 ROOM F4
p.v
roofing tiles on 50mm x 50mm battens on
CHECKED BY:
(ceramic tiles ff) (ceramic tiles ff) 75mm x 50mm truses to S.E details.
3,400

3,400

3,400

3,400
(ceramic tiles ff) (ceramic tiles ff)
3,200

3,200
900

900
8

p.v p.v p.v p.v

600

3,222
2,925
250

250

±0.000 +2.700
whb
shw I.C shw
whb whb
shw shw
whb
600

900

600

p.v p.v p.v p.v

2,325
wc wc wc wc
3 3 3 3
500

200

500
6,600
200

200

200
wc g.t g.t wc wc wc
600

900

600

600
p.v p.v p.v p.v
whb whb whb whb
shw shw shw shw
18,100
18,200

18,200

18,200

18,200
p.v
250

250

p.v p.v
p.v

300
100

S-X S-X S-X S-X WALL SPECS


3,400

3,400

3,400

3,400
E-4

E-4
Void
900

900

p.v p.v p.v p.v

ROOM S3
3,200

3,200

3,200
Plastered and Painted with

2,700
ROOM S8
E-2

E-2

ROOM G3 ROOM F3 ROOM F8


Passage

ROOM G8 Wall Master Finish

2,400

1,800
2,200

I.C
1,100

1,100

(ceramic tiles ff) p.v p.v (ceramic tiles ff) (ceramic tiles ff) p.v p.v (ceramic tiles ff)
I.C I.C
BEAM SPECS

600 300
4 4 4 4
600

600

300mm x 200mm R.C beam to Project


g.t
200

100 2,200 200

200

200

200

p.v p.v p.v S.E details

300
PROPOSED DEVELOPMENT FOR
1,100

1,100

p.v p.v
p.v p.v
ROOM F9

2,700
ROOM G2 ROOM G9 ROOM F2 ROOM F3 ROOM F8 ESTHER WAITHIRA KIMANI
3,400

3,400

3,400

3,400

(ceramic tiles ff)

2,400

1,800
(ceramic tiles ff) (ceramic tiles ff)
3,200

3,200

3,200

P.O BOX
900

900

p.v
Septic p.v (ceramic tiles ff) p.v p.v

Tank
250

250

shw g.t g.t shw shw shw

300
whb whb whb whb
600

900

600

p.v p.v p.v p.v ON LR. NO. Ruiru/Ruiru East Block 2/5817
wc
I.C I.C wc wc wc p.v p.v p.v
300
R.C FLOOR SLAB SPECS
5 5 5 5
500

200

500
6,600

shw 150mm R.C floor slab to S.E details on


200

200

200

2,700

wc wc wc wc

600
ROOM G3
600

900

600

whb
p.v p.v whb whb
p.v p.v whb ROOM G8 1000G polythene sheet on 25mm blinding on
2,400
shw shw p.v shw
50
250

p.v
approved compacted hardcore filling. Cleint
100

200
3,400

3,400

3,400

3,400
900

p.v p.v p.v


ROOM G10
p.v ESTHER WAITHIRA KIMANI
G.L FOUNDATION SPECS
3,200

3,200

3,200

ROOM G1 ROOM F1 LOUNGE ROOM F10 All R.C foundation & struct.elements to s.e details

1,800
(ceramic tiles ff)
2,200

2,200

150

150

(ceramic tiles ff) (ceramic tiles ff)


1,100

(ceramic tiles ff) p.v p.v p.v


(ceramic tiles ff) on 50mm1:4:8 concrete blinding,hardcore on firm
ground free from loose soil or base. depthsto be Cleint Signature.................. Date...................
200

determined on site by S.E. contractor to


6 p.v 6 6 p.v
p.v
p.v
6 SECTION Y-Y excavate,remove &cart away all loose & black
Drawing
200

200

200

200

200

200

200

cotton soils from below new buildings prior to TYPICAL GROUND,1st & 2nd FLOOR PLANS
1,275 1,500 2,650 1,500 2,500 1,500 1,275 commencing foundation.
200 3,575 200 1,375 1,650 1,225 200 3,575 200
ELEVATIONS, SECTION AND SITE PLAN.
200 2,575 200 3,950 200 1,100 200 3,575 200
12,200
12,200 Drawn by: Date:

3,775 4,450 3,775 3,775 4,450 3,775 L.K.K JUNE 2016.

Design by: Date:


A B C D A B C D L.K.K JUNE 2016.
E-1 E-1
Drawing Scale
S-Y

S-Y

GROUND FLOOR PLAN 1 : 100,200,500


scale 1:00
TYPICAL 1ST& 2ND FLOOR PLAN Layout ID Status Revision
scale 1:00
GSPublisherEngine 0.0.100.100

Vous aimerez peut-être aussi