Académique Documents
Professionnel Documents
Culture Documents
design elements
design
Open mono-stringer
M2 is of particular importance.
The mono-stringer’s position
Lower structural floor
underneath and away from
the edges of the treads makes
1
it retreat from view, and
allows the impression of the
staircase to be dominated by
the treads themselves from all
angles. The impression of the
stringer is often further played
down, through the choice of a
dark or neutral pre-finish coat. Void edge
nosing
Alternatively, one may choose
to highlight its characteristics
Riser board
of strength and purity of line
by choosing a more dramatic
colour for its coating. Arden’s
customers frequently choose
to complement the MS2 with
a glass balustrade to maintain
8mm thick steel
the translucent character of gusset supports
12mm tread plate
this staircase.
M2
Plaster board
Visual
connection
detail
2 www.arden.net.au
As with all open staircases,
Open mono-stringer
Floor coverings Top tread
the BCA rule on a gap of less
than 125mm being required
Top support plate
between the top of a tread
welded to top floor and the underside of the
fixing plate
Concealed connection detail
tread above. Most modern
staircases have a rise per
tread of between 170mm and
190mm, thereby requiring a
functional tread thickness of
8mm thick steel
gusset supports between 45mm and 65mm.
12mm tread plate
The tread solutions for open
Chemical anchors
for concrete floors staircases applicable to the
Fixing plate M2 are provided in Arden
Suspended ceiling technical data sheet ‘A.3
Treads’. The details illustrated
draw upon these tread
solutions.
3
M2
design elements 3
technical
Open mono-stringer
4 www.arden.net.au
AK AK
Open mono-stringer
Floor coverings
Concrete recessed
and filled with grout
to conceal connection
35.8°
200 AM
P7
P8
Concrete recessed
M2
design elements 5
Figure 9. Typical bolted stringer to
Open mono-stringer
TYPICAL STRINGER TO STRINGER
stringer connection detail. BOLTED CONNECTION DETAIL
Under landing
section of upper
flight stringer
Raked section of
lower flight stringer
Counter sunk
stainless steel screws
Welds
10
M2
Tread scribed
around SHS
8mm gusset
11
6 www.arden.net.au
Open mono-stringer M2
7
design elements
Open mono-stringer
Stringer
Y
Applied nosings typically 19mm
hide end-grain & inter-layers
Tread plate (underneath)
AA
Y SECTION Y-Y
SCALE 1 / 25
Non-slip insert
12
Welds
Mono-stringer
13
M2
8 www.arden.net.au
AH
AJ
AH
AJ
Open mono-stringer
Folded tread support bracket (underneath) Rubber/vinyl inlay
Stringer
AH SECTION AH-AH
SCALE 0.07 : 1
AH SECTION AH-AH
14 SCALE 0.07 : 1
P 15
P 15
M2
15
design elements 9
Open mono-stringer
P 16 P 1
Inserted
Inserted wood blockwood block (shown)
(shown)
or welded or welded
inner inner sleeve
sleeve
preventsofcrushing
prevents crushing SHS of SHS
8mm gusset
8mm gusset
C4 balustrade
C4 balustrade
M2
shown connected
shown connected
to tread ends
to tread ends
M10epoxy
M10 (typical) (typical) epoxy
glued intoglued
timberinto timber treads
treads
16
10 www.arden.net.au
About this document
Open mono-stringer
Intellectual property is copyright © Archstairs
Pty Ltd unless otherwise agreed in writing. All
rights to the document are retained. Any use
of the document by clients or third parties,
unless specifically authorised by Archstairs
Pty Ltd, are at their own risk and the user
releases and indemnifies Archstairs Pty Ltd
from and against all loss or damage arising
from such use.
compliance
Arden is a BSA licensed contractor for carpentry, joinery, glass, glazing Key
and aluminium as well as structural metal fabrication and erection. Arden full compliance with the code
supplies a Form 16 (Licensed Contractor) on all projects. In design and can comply
construct contracts, a Form 15 (Design Engineer) certification is supplied does not comply
upon request. For products and services incorporating the M2 system, this not applicable to this element
table shows compliance with relevant codes and standards.
design note
For all commercial applications, it is important that sufficient space
for the stairwell cavity be allowed to satisfy Australian Standards
and BCA requirements.
The footprint is primarily driven by the floor to floor rise, as well as the
staircase configuration chosen. However, stringer and balustrade style design
may increase the amount of space required. Allowing too small a cavity can
restrict the design options of the staircase. Also, points at where the staircase
interacts with other structures are best addressed early in the design cycle.
Consultation with Arden early on will help ensure that these design issues
can be addressed in a cost-effective manner.
design elements 11
www.arden.net.au
phone (07) 3267 6100 | fax (07) 3267 6500 | email admin@arden.net.au
Office & factory: 46 Radley Street Virginia Qld 4014 Australia Postal address: PO Box 317 Virginia Qld 4014 Australia