REPUBLIC OF THE PHILIPPINES

DEPARTMENT OF PUBLIC WORKS & HIGHWAYS


TECHNICAL DESCRIPTION OFFICE OF THE BUILDING OFFICIAL

LOT 2747-D-7-C PSD-00-87898


LINES BEARINGS DISTANCES
1-2 N 35°12' W 18.50 M.
2-3 N 57°55' E 11.55 M. District/City/Municipality
3-4 N 80°50' E 01.94 M.
4-5 S 42°33' E 03.80 M.
5-6 S 37°14' E 09.63 M.
6-7 S 35°49' E 03.50 M.
7-1 S 54°23' E 14.15 M.
LAND USE & ZONING
4
TE
ILN
I ES
:17°53W
' 1,344
.2MF
.ROM
3
LM. 1.5M
, ALN
I TAESTATE

1 8-A
T5
LO
5

LINE & GRADE

LO
T
PERSPECTIVE

51
8-
B-
NOT TO SCALE 2

3
2 ARCHITECTURAL

MALINTA 6
2.9
7
0
4.5

.
MIRANDA COMPOUND Z A RD
PLA
A DUA A. P
1.5 1
P A B L
3
ET

O ST STRUCTURAL
TRO
RE

Z .
NDE
ST

NA
DE CAS

7
HER O
O

NGC
IAG

. TO
TAN

0.6

KAP
NT

6
ST. LOUIS OS
SA

GKE

-D
COMPOUND ANT
P. S
I.

ONG

18
A
STR
V.

MOR
GO

STO

5
AGO
E

A
SN. JULIAN
ET

T
5.7

LO
3
SN. R IA
. MA SANITARY/ PLUMBING
STA A
SAIN

LIL . RIT
B
STA
11
AC R
.25
T JU

PI L A 1.3
0
N
DE

CIO
BUE

OLA
ST.

S AL 1
B-
CO N
NAV

SAM
8-
3.5 C
NI
ENT

ORA 51
6
MAP

T
URA

LO
LE

D
ELECTRICAL
1
VICINITY MAP
NOT TO SCALE
SITE DEVELOPMENT PLAN
SCALE 1:150 METERS
MECHANICAL
THESE DRAWINGS ARE PROJECT OWNER: PROJECT TITLE / LOCATION: REVISIONS: DATE SHEET CONTENTS: SHEET NO.
I N S T R U M E N T O F
INTELLECTUAL AND
PROFESSIONAL SERVICES
A N D P R O H I B I T S
R E P R OD U C TI O N S O R U S E
SPS. MANUEL EDGAR & TERESA
ELEUTERIA QUIRANTE
AS-BUILT 1 STOREY COMMERCIAL BUILDING A1
WITHOUT THE PRIOR

ARCHITECT
W R IT TE N C ON S E N T FR OM
T H E A R C H I T E C T
- R A 5 4 5
1477 IBAYO ST., MALINTA, VALENZUELA CITY 1
A B C D A B C D
11.25 11.25
0.66 5.73 1.30 3.56 0.66 5.73 1.30 3.56

1 1

D-2
C.R.
1.53 1.53

FIREWALL
SHOP
4.50 4.50
OFFICE

2.97 2.97

D-1 D-1 D-1


2 2
W-1 W-2 W-3

GROUND FLOOR PLAN ROOF PLAN


SCALE 1:100 METERS SCALE 1:100 METERS

A B C D D C B A 1 2
11.25 11.25 4.50
0.66 5.73 1.30 3.56 3.56 1.30 5.73 0.66

ROOF APEX

1.00

ROOF BEAM LINE

4.00
3.00

FINISH FLOOR LINE

FRONT ELEVATION REAR ELEVATION LEFT SIDE ELEVATION


SCALE 1:100 METERS SCALE 1:100 METERS SCALE 1:100 METERS

THESE DRAWINGS ARE PROJECT OWNER: PROJECT TITLE / LOCATION: REVISIONS: DATE SHEET CONTENTS: SHEET NO.
I N S T R U M E N T O F
INTELLECTUAL AND
PROFESSIONAL SERVICES
A N D P R O H I B I T S
R E P R OD U C TI O N S O R U S E
SPS. MANUEL EDGAR & TERESA
ELEUTERIA QUIRANTE
AS-BUILT 1 STOREY COMMERCIAL BUILDING A2
WITHOUT THE PRIOR

ARCHITECT
W R IT TE N C ON S E N T FR OM
T H E A R C H I T E C T
- R A 5 4 5
1477 IBAYO ST., MALINTA, VALENZUELA CITY 2
A B C D 2 1 2 1
11.25 4.50 4.50
0.66 5.73 1.30 3.56

ROOF APEX

SEE TRUSS DETAILS

ROOF BEAM LINE

4.00

FINISH FLOOR LINE

LONGITUDINAL SECTION RIGHT SIDE ELEVATION RIGHT SIDE ELEVATION


SCALE 1:100 METERS SCALE 1:150 METERS SCALE 1:150 METERS

1.07
0.86 METERS 0.60 METERS VARIES VARIES

1.00 METERS 1.07


2.10 METERS

2.10 METERS

1.10 METERS

1.40 3.00

FINISHED FLOOR LINE


D-2

D1 TYPE
GLASS DOOR
D2 TYPE
PVC FLUSH DOOR
W1 TYPE
SLIDING WINDOW

LOC. ENTRANCE LOC. TOILET AND BATH LOC. SHOP, OFFICE


SET/S: 3 SET/S: 1 SET/S: 4

TOILET DETAILS
DOORS & WINDOW SCHEDULE
SCALE 1:40 METERS
SCALE 1:40 METERS

THESE DRAWINGS ARE PROJECT OWNER: PROJECT TITLE / LOCATION: REVISIONS: DATE SHEET CONTENTS: SHEET NO.
I N S T R U M E N T O F
INTELLECTUAL AND
PROFESSIONAL SERVICES
A N D P R O H I B I T S
R E P R OD U C TI O N S O R U S E
SPS. MANUEL EDGAR & TERESA
ELEUTERIA QUIRANTE
AS-BUILT 1 STOREY COMMERCIAL BUILDING A3
WITHOUT THE PRIOR

ARCHITECT
W R IT TE N C ON S E N T FR OM
T H E A R C H I T E C T
- R A 5 4 5
1477 IBAYO ST., MALINTA, VALENZUELA CITY 3
CONSTRUCTION NOTES
A. GENERAL
1. CONSTRUCTION NOTES AND TYPICAL DETAILS APPLY TO ALL DRAWINGS UNLESS
OTHERWISE SHOWN OR NOTED. MODIFY TYPICAL DETAILS AS DIRECTED TO MEET
SPECIAL CONDITIONS.

2. SHOP DRAWINGS WITH ERECTION AND PLACING DIAGRAMS OF ALL STRUCTURAL


STEEL, MISCELLANEOUS IRON, PRE-CAST CONCRETE ETC. SHALL BE SUBMITTED
A B C D A B C D FOR ENGINEER'S APPROVAL BEFORE FABRICATION.

3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS BEFORE ALL WORK IS TO BEGIN,


11.25 11.25 CHECK WITH MECHANICAL AND ELECTRICAL CONTRACTORS FOR CONDUITS, PIPE
SLEEVES, ETC. TO BE EMBEDDED IN CONCRETE.
0.66 5.73 1.30 3.56 0.66 5.73 1.30 3.56 4. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADEQUATE
SHORINGS AND BRACINGS OF THE STRUCTURE FOR ALL LOADS THAT MAYBE
IMPOSED DURING CONSTRUCTION.
1 1
B. CONCRETE & REINFORCEMENT
FTB-1 FTB-1 FTB-1 RB-1 RB-1 RB-1

CB-1
WF-1

WF-1
1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM WITH THE LATEST BUILDING
CODE OF AMERICAN CONCRETE INSTITUTE (ACI-318).
1.53 1.53
2. ALL CONCRETE SHALL DEVELOP A MINIMUM COMPRESSIVE STRENGTH AT THE
END OF TWENTY EIGHT (28) DAYS WITH CORRESPONDING MAXIMUM SIZE
C1/F1 C1/F1 WF-1 C1/F1 C1/F1 AGGREGATE AND SLUMPS AS FOLLOWS :

CB-1 LOCATION 28 DAYS STRENGTH MAX. SIZE AGGREGATE MAX. SLUMP

RB-1

RB-1

RB-1

RB-1
FTB-1

FTB-1

FTB-1

FTB-1

T-1

T-1

T-1

T-1
4.50 4.50 CURBS & SLAB
ON GRADE 3000 PSI(210KG/CM2) 1 IN. (25MM.) 4 IN. (100MM.)
EXCEPT FOUND.
FOUNDATION & 3000 PSI(281KG/CM2) 3/4 IN. (19MM.) 4 IN. (100MM.)
2.97 C1/F1 C1/F1 C1/F1 C1/F1 2.97 RETAINING WALL,
BEAMS, COLUMNS
& SLABS

3. ALL REINFORCING BARS SHALL CONFORM TO ASTM A615 (PNS 49) GRADE 40
FTB-1 FTB-1 FTB-1 RB-1 RB-1 RB-1 FOR DIA. 16 AND SMALLER BARS AND GRADE 60 FOR DIA. 20 AND LARGER BARS.

2 2 4. IN GENERAL, THE LATEST EDITION OF ACI-315, MANUAL OF STANDARD PRACTICE


DETAILING REINFORCED CONCRETE STRUCTURES SHALL BE ADHERED TO, UNLESS
OTHERWISE SHOWN OR NOTED.
SLAB ON GRADE
100mm THK W/ 10mm dia SAGROD (AS SPACED) WELDED @ 1.0 M.O.C.
5. MAINTAIN MINIMUM CONCRETE COVER FOR REINFORCING STEEL AS FOLLOWS:
REBARS SPACED @ 400mm
12 MM. Ø PLAIN GA.16, 2"x7" C-PURLINS SUSPENDED SLABS ..................................................... 3/4 IN. ( 19 MM. )
O.C.B.W. ON 50mm THK
WELL COMPACTED SAND SLAB ON GRADE ......................................................... 1 1/2 IN. ( 38 MM. )
AND GRAVEL BEDDING
WALLS ABOVE GRADE ................................................. 1 IN. ( 25 MM. )

FOUNDATION PLAN ROOF FRAMING PLAN


BEAM STIRRUPS AND COLUMN TIES .......................... 1 1/2 IN. ( 38 MM. )

WHERE CONCRETE IS EXPOSED TO EARTH


BUT POURED AGAINST FORMS ................................... 2 IN. ( 50 MM. )
SCALE 1:100 METERS
SCALE 1:100 METERS WHERE CONCRETE IS DEPOSITED
DIRECTLY AGAINST EARTH ........................................... 3 IN. ( 75 MM. )
6. SPLICES SHALL BE SECURELY WIRED TOGETHER AND SHALL LAP OR EXTEND IN
ACCORDANCE WITH TABLE 1 (TABLE OF LAP SPLICE AND ANCHORAGE LENGTH)
UNLESS OTHERWISE SHOWN ON DRAWINGS, SPLICES SHALL BE STAGGERED

SCHEDULE OF BEAM : WHENEVER POSSIBLE.


7. ALL ANCHOR BOLTS, DOWELS, AND OTHER INSERTS, SHALL BE PROPERLY
POSITIONED AND SECURED IN PLACE PRIOR TO PLACING OF CONCRETE.
LEFT SUPPORT MID-SPAN RIGHT SUPPORT 8. CONTRACTOR SHALL NOTE AND PROVIDE ALL MISCELLANEOUS CURBS, SILLS,
MARK STOOLS, EQUIPMENTS, AND MECHANICAL BASES THAT ARE REQUIRED BY THE
TOP BAR BOTTOM BAR TOP BAR BOTTOM BAR TOP BAR ARCHITECTURAL, ELECTRICAL, AND MECHANICAL DRAWINGS.
BAR Ø DIMENSION
( MM. ) MIDDLE BAR B x D ( MM. ) 9. ALL CONCRETE SHALL BE KEPT MOIST FOR A MINIMUM OF SEVEN (7)
STIRRUPS
FTB 4 4 4 4 4 BOTTOM BAR
CONSECUTIVE DAYS IMMEDIATELY AFTER POURING BY THE USE OF WET BURLAP,
4 16 2-12 MM. Ø 250 x 300 FOG SPRAYING, CURING COMPOUNDS OR OTHER APPROVED METHODS.
RB-1 4 2 2 4 4 A
2 16 2-12 MM. Ø 250 x 300 B 10. STRIPPING OF FORMS AND SHORES:
STIRRUPS A - USE 10 MM. Ø SPACE @ 4 - 0.05, 4 - 0.10, 4 - 0.15, REST @ 0.20 M.O.C.
FOUNDATION ................................................................ 24 HRS.
( USE )
B - USE 10 MM. Ø @ 2 - 0.05, 3 - 0.10, 4 - 0.15, REST @ 0.20 M.O.C. SUSPENDED SLAB EXCEPT WHEN
ADDITIONAL LOADS ARE IMPOSED ............................. 8 DAYS

SCHEDULE OF COLUMN : SCHEDULE OF FOOTING : WALLS ......................................................................... 18 HRS.


BEAMS ........................................................................ 14 DAYS
S I Z E ( M. ) BOTTOM BARS
THICKNESS DEPTH OF
C. CAMBER REQUIREMENTS
MARK C-1 MARK
( MM. ) WIDTH LENGTH BAR - 'S' BAR - 'L' EXCAVATION
REMARKS

1. UNLESS OTHERWISE NOTED ON THE PLANS OR SPECIFICATIONS CAMBER ALL R.C.


F1 300 1.50 1.50 8 - 16 MM. Ø 8 - 16 MM. Ø 1.50 M. CENTER & SIDE FOOTING BEAMS AT LEAST 10mm FOR EVERY 4000mm OF CLEAR SPAN EXCEPT CANTILEVERS
0.20 WHICH SHALL BE 50mm FOR EVERY 3000mm OF CLEAR SPAN.
WF 200 0.45 VARIES 12 MM. Ø @ 0.30 M.O.C. 3 - 12 MM. Ø TEMP. BAR 0.60 M. SIDE WALL FTG. 2. UNLESS OTHERWISE NOTED ON THE PLANS OR SPECIFICATIONS, CAMBER ALL R.C.
SLABS 8mm PER 3000mm OF SHORTER SPAN AND 14mm FOR EVERY 2000mm OF
NOTE: NO FOOTING SHOULD REST ON BACKFILL MATERIALS. CANTILEVER SPAN.

SCHEDULE OF SLAB : D. FOUNDATION


0.40

1. FOUNDATION IS DESIGNED FOR AN ASSUMED ALLOWABLE SOIL CAPACITY OF 2500 psf.


FOUNDATION R E I N F O R C E M E N T
2. FOUNDATION SHALL REST ON NATURAL SOIL. UNLESS OTHERWISE NOTED BY
to ROOF BEAM THICKNESS
REBAR
THE ENGINEER, NO PART OF THE FOUNDATION SHALL REST ON FILL.
MARK Ø PARALLEL TO SHORT SPAN PARALLEL TO LONG SPAN REMARKS
( MM. )
( MM. ) 3. THE CONTRACTOR SHALL NOTIFY THE ENGINEER AFTER FOOTING EXCAVATION
TOP BAR @ SUPPORT BOTTOM BAR @ SUPPORT TOP BAR @ SUPPORT BOTTOM BAR @ SUPPORT HAVE BEEN COMPLETED AND PRIOR TO CONCRETING TO CONFIRM THE DESIGN
SOIL BEARING CAPACITY.
12 MM. Ø @ 0.15 M.O.C. 12 MM. Ø @ 0.25 M.O.C. 12 MM. Ø @ 0.15 M.O.C. 12 MM. Ø @ 0.30 M.O.C.
S1 100 12 TWO-WAY
BENT-UP 2/3 @ L/4 BENT-UP 2/3 @ L/4 BENT-UP 2/3 @ L/4 BENT-UP 2/3 @ L/4 4. THE CONTRACTOR SHALL PROVIDE FOR DESIGN AND INSTALLATION OF
S I Z E : 200 x 400 MM. ALL CRIBBING, SHEATHING AND SHORING NECESSARY TO SAFELY RETAIN
12 MM. Ø @ 0.25 M.O.C. 12 MM. Ø @ 0.30 M.O.C.
S2 100 12 ONE-WAY SHEET CONTENTS :
BENT-UP 2/3 @ L/4 BENT-UP 2/3 @ L/4
NO. OF VERT. BARS : 6 PCS. - 16 MM. Ø DEFORMED BAR
SLAB ON FILL 100 12 12 MM. Ø @ 0.50 M.O.C. 12 MM. Ø @ 0.50 M.O.C. ON FILL
USE 10 MM Ø TIES SPACE @ 4-0.05M.
TIES : 4-0.10M. 4-0.15M. REST @ 0.20M.

THESE DRAWINGS ARE PROJECT OWNER: PROJECT TITLE / LOCATION: REVISIONS: DATE SHEET CONTENTS: SHEET NO.
I N S T R U M E N T O F
INTELLECTUAL AND
PROFESSIONAL SERVICES
A N D P R O H I B I T S
R E P R OD U C TI O N S O R U S E
SPS. MANUEL EDGAR & TERESA
ELEUTERIA QUIRANTE
AS-BUILT 1 STOREY COMMERCIAL BUILDING S1
WITHOUT THE PRIOR

CIVIL ENGINEER
W R IT TE N C ON S E N T FR OM
T H E A R C H I T E C T
- R A 5 4 5
1477 IBAYO ST., MALINTA, VALENZUELA CITY 4
BEAM OR SLAB BEAM OR SLAB
12mmØ @400
REINF. 10mm Ø TIES SPACED 2
10mm Ø TIES SPACED 2 @ 0.05m, 5 @ 0.10m AND
4" OR 6" CHB
@ 0.05m, 5 @ 0.10m AND REST @ 0.15m
2 - 16mmØ A A REST @ 0.15m 16mm Ø STIRRUPS
Ø12 @400mm
10mmØ TIES B 16mm Ø TOP BARS
250

B
@150mm.DOWELS
O.C. BAR
B B WINDOW OPENING

50 100
2 - 16mmØ 1-Ø16
50

DOOR OPENING

B
L/4 16mm Ø BOTTOM BARS
100 FOR 1OOTHK CHB

150 FOR 150THK CHB SECT B COLUMN


L/4
BEAM OR SLAB BEAM OR SLAB
SECTION A
COLUMN
TYP. DOOR / WINDOW OPENING
& LINTEL BEAM DETAILS BEAM AND COLUMN DETAILS
NOT TO SCALE NOT TO SCALE
LENGTH OF SLAB

L 1/4 L 1/4
B LENGTH OF BEAM TOP BAR @ SL
SEPARATOR BAR
(AS SPECIFIED) DISTRIBUTION OF BEAM STIRRUPS (SEE BEAM SCHEDULE)
L 1/4 L 1/4 TOP BAR @ SUPPORT (Ss)
TOP BAR TOP BAR 50 MM. SEPARATOR BAR STIRRUPS BAR 50 MM.
(SPACED AS SPECIFIED) STIRRUPS BAR TOP BARS @ MIDSPAN (Ss)
L-SUPPORT (AS SPECIFIED) R-SUPPORT
M-SUPPORT (SPACED AS SPECIFIED) TOP BAR
D MIDDLE BAR D MIDDLE BAR TOP BAR TOP BAR
(AS SPECIFIED) T
(AS SPECIFIED) MIDDLE BAR
D B B
(AS SPECIFIED)
BOTTOM BAR BOTTOM BAR BOTTOM BARS @ MIDSPAN (Ss)
SEPARATOR BAR L-SUPPORT M-SUPPORT R-SUPPORT BOTTOM BARS (CONTINEOUS)
(AS SPECIFIED) BOTTOM BAR SEPARATOR BAR BOTTOM BAR BOTTOM BAR
(AS SPECIFIED)

@ L/R SUPPORT @ MIDSPAN


ELEVATION BOTTOM BAR @ SL SLAB ON GRADE
SECTION

SLAB DETAILS
CROSS BRACING DETAILS
NOT TO SCALE
NOT TO SCALE

0.15
0.10
GA.16, 2" x 6" C-PURLINS
WELDED @ 1.00 M.O.C. 0.80

0.24

0.84
0.60
STD. TURN-BUCKLE FULLY-WELDED
16 MM. Ø PLAIN CONNECTION 0.40 1.48 1.48 0.40
VERIFY 1.26

0.30
SAG ROD
VARIES
0.20

0.30
10 MM. THK.

0.60

0.60
BUCKLE PLATE
± 26.00 M. VARIES

20 MM. Ø PLAIN BAR


CROSS-BRACING

TRUSS DETAIL
CROSS BRACING DETAILS
C- PURLINS DETAILS NOT TO SCALE
NOT TO SCALE
NOT TO SCALE

THESE DRAWINGS ARE PROJECT OWNER: PROJECT TITLE / LOCATION: REVISIONS: DATE SHEET CONTENTS: SHEET NO.
I N S T R U M E N T O F
INTELLECTUAL AND
PROFESSIONAL SERVICES
A N D P R O H I B I T S
R E P R OD U C TI O N S O R U S E
SPS. MANUEL EDGAR & TERESA
ELEUTERIA QUIRANTE
AS-BUILT 1 STOREY COMMERCIAL BUILDING S2
WITHOUT THE PRIOR

CIVIL ENGINEER
W R IT TE N C ON S E N T FR OM
T H E A R C H I T E C T
- R A 5 4 5
1477 IBAYO ST., MALINTA, VALENZUELA CITY 5
A B C D A B C D
11.25 11.25
0.66 5.73
NOT 1.30
TO 3.56
SCALE 0.66 5.73 1.30 3.56

1 1
WC WC
CO
1.53 LAV FD 1.53 LAV

CB
CV
WM
4.50 4.50
GV

2.97 2.97
TAP TO STREET
DRAINAGE ST
MH MH

CB CB
2 2
TAP TO NEAREST WATER
SUPPLY SYSTEM
TAP TO MAIN SEWER LINE

TAP TO STREET TAP TO STREET WATER LINE LAYOUT


DRAINAGE DRAINAGE
@ GROUND FLOOR SCALE 1:100 METERS

A B C D
11.25
0.66 5.73 1.30 3.56

DS DS DS DS
1

1.53
MALINTA
D.
PIPE SCHEDULE : MIRANDA COMPOUND ZA R
PLA
UA
PLUMBING LINE MAIN PIPE SECONDARY PIPE PAD A. P
A B L

TRO
O ST

EE
4.50 DEZ .

R
NAN

ST

DE CAS
WATER LINE 3/4" Ø G.I. PIPE 1/2" Ø G.I. PIPE
HER O

O
NGC

IAG
. TO

TAN
2.97 SEWER LINE 4 " Ø uPVC PIPE 2" - 3" Ø uPVC PIPE
KAP

NT
ST. LOUIS
OS

SA

G
ANT

KE
COMPOUND
P. S

I.
STORM DRAINAGE LINE 6 " Ø uPVC PIPE 3" - 4" Ø uPVC PIPE
ONG

STR
V.
MOR

GO
STO
AGO

EET
A
DOWNSPOUT 4 " Ø uPVC PIPE
SN. JULIAN
SN. RIA
2 DS DS .M A
STA

SAIN
A
LIL . RIT
@ ROOF AC STA R

T JU
PI L A
ION

DE
BUE
C
OLA

ST.
N S AL

NAV
CO SAM
NI

ENT
OR A

MAP
URA

K
LE
SEWER LINE & STORM
DRAINAGE LAYOUT VICINITY MAP
SCALE 1:100 METERS NOT TO SCALE

THESE DRAWINGS ARE PROJECT OWNER: PROJECT TITLE / LOCATION: REVISIONS: DATE SHEET CONTENTS: SHEET NO.
I N S T R U M E N T O F
INTELLECTUAL AND
PROFESSIONAL SERVICES
A N D P R O H I B I T S
R E P R OD U C TI O N S O R U S E
SPS. MANUEL EDGAR & TERESA
ELEUTERIA QUIRANTE
AS-BUILT 1 STOREY COMMERCIAL BUILDING P1
WITHOUT THE PRIOR

MASTER PLUMBER
W R IT TE N C ON S E N T FR OM
T H E A R C H I T E C T
- R A 5 4 5
1477 IBAYO ST., MALINTA, VALENZUELA CITY 6
GENERAL NOTES ON PLUMBING /
SANITARY SYSTEM
125MM THK. CONC. 1. ALL PLUMBING / SANITARY WORKS INCLUDED HEREIN
SLAB WITH 10MMØ
SHALL BE EXECUTED ACCORDING TO THE PROVISIONS OF

2.00
REBAR @ 150MM
O.C. B.W.
500X500MM
THE NATIONAL PLUMBING CODE OF THE PHILIPPINES
TO SUPPLY 100MMØ INLET MANHOLE WITH ( NPCP ), THE NATIONAL BUILDING CODE ( NBC ) AND ITS
2Omm GATE VALVE/ PIPE CONC. COVER IMPLEMENTING RULES AND REGULATIONS, AND
APPLICABLE LAWS, CODES AND ORDINANCES OF VALENZUELA
WATER METER CITY.
DS
2. ALL PLUMBING / SANITARY WORKS, INSTALLATIONS
AND WORKMANSHIP SHALL BE SUPERVISED BY A DULY
LICENSED PLUMBING ENGINEER / SANITARY ENGINEER.

FROM MAIN WATERLINE 3. ALL PIPES, FITTINGS AND OTHER DEVICES SHALL BE

DS
DS
1.10 MH MH
PIPE
INSTALLED AS INDICATED INTHE PLANS. ANY RELOCATION
REQUIRED FOR THE EXECUTION OF OTHER TRADES

PLAN DIGESTIVE
CHAMBER
LEACHING
CHAMBER
SHALL BE WITH PRIOR APPROVAL OF THE ENGINEER
CONCERNED.
4. EXCAVATION, PIPE LAYING AND BACKFILLING SHALL
DS BE PERFORMED ACCORDING TO THE RECOMMENDED SLOPE

2.00 AS APPROVED IN SEC. 154 OF THE NATIONAL PLUMBING


CODE OF THE PHILIPPINES ( NPCP ) WHICH STATES:
" ALL HORIZONTAL PIPING SHALL BE RUN IN
100Ø INLET FCO FCO FCO
PIPE
PRACTICAL ALIGNMENT AND AT A UNIFORM
DS GRADE OF NOT LESS THAN TWO PERCENT (2%)."
5. ALL PIPING SYSTEMS, IF NECESSARY SHALL BE
SUPPORTED BY MEANS OF HANGERS, BRACES, CLAMPS,
WATER LEVEL
FINISH FLOOR LINE AND OTHER MEANS OF PIPE SUPPORTS. HORIZONTAL
PIPES SHALL BE SUPPORTED AT INTERVALS NOT TO

DS
2.20 LEACHING
CHAMBER EXCEED 3048 mm. (10 FT.).
6. COLD WATER SUPPLY PIPE ESPECIALLY GALVANIZED
DIGESTIVE DIGESTIVE CHAMBER IRON PIPE SHALL BE COATED WITH AN APPROVED
CB CHAMBER 1% SLOPE
ANTI-RUST PAINT / RED OXIDE / RED LEAD PAINT.
7. NO BUILDING / HOUSE COLD WATER SUPPLY ( CWS )
ELEVATION/SECTION PIPE SHALL BE LESS THAN 13 mm Ø ( 1/2 Ø ) UNLESS
TA OTHERWISE SPECIFIED.
DRP TO
CB AIN S
AGTRE
E ET
8. SYSTEM OF TEST. ALL THE PIPING OF THE PLUMBING
SYSTEM SHALL BE TESTED WITH WATER HAVING A
PRESSURE HEAD OF ATLEAST 1500mm ( 5 FT. ).
TA
DRP TO
AIN S
AGTRE
LA
V
WC WATER METER DETAIL SEPTIC TANK DETAIL 9. VENT THRU ROOF SHALL BE PROVIDED WITH
FD C SEALANTS LEAD OR GALVANIZED IRON FLASHING OR
E ET MH O
ST NOT TO SCALE NOT TO SCALE OTHER MEANS OF WEATHER PROTECTION DEVICES. IT
TA MH SHALL EXTEND 305 mm ( 1 FT. ) ABOVE THE ROOF.
P TO
MA 10. ALL ITEMS OR PARTS, SUCH AS FITTINGS, VALVES,
IN
SE FIXTURES, AND / OR APPURTENANCES, WETHER THESE
WE
RL PARTS HAVE BEEN SPECIFICALLY MENTIONED OR NOT
INE
INDICATED IN THE DRAWINGS, SHALL BE INSTALLED AND
FURNISHED IF NECESSARY TO COMPLETE THE PLUMBING
SYSTEM IN ACCORDANCE WITH THE BEST PRACTICE OF
CB PLUMBING TRADE AND PROFESSION.

TA CHB WALL
DRP TO

C
W V
AIN S
AGTRE
E ET L E G E N D
GV M

SYMBOL ABBREV. ITEM


T WC
WAAP T LA
V
SYTERO NE
ST SU AR WATER CLOSET
EM PP ES WC
LY T
PLAN LAV LAVATORY
FLOOR FLANGE SQUARE STRAINER
WITH SLOT OPENING KS KITCHEN SINK
LS LAUNDRY SINK
38Ø VENT. PIPE
SD SHOWER DRAIN

SH SHOWER HEAD
GV GATE VALVE
100Ø
CV CHECK VALVE
19Ø CWL
CWL COLD WATER LINE
38Ø VENT
ELEVATION SECTION
SECTION SP SOIL PIPE
SS SOIL STACK
WS WASTE STACK

PLUMBING ISOMETRY WATER CLOSET DETAIL SHOWER DRAIN WP WASTE PIPE

NOT TO SCALE NOT TO SCALE CO CLEAN OUT


NOT TO SCALE VS VENT STACK
VP VENT PIPE

DIA DIAMETER
CB CB CATCH BASIN
ST SEPTIC TANK

THESE DRAWINGS ARE PROJECT OWNER: PROJECT TITLE / LOCATION: REVISIONS: DATE SHEET CONTENTS: SHEET NO.
I N S T R U M E N T O F
INTELLECTUAL AND
PROFESSIONAL SERVICES
A N D P R O H I B I T S
R E P R OD U C TI O N S O R U S E
SPS. MANUEL EDGAR & TERESA
ELEUTERIA QUIRANTE
AS-BUILT 1 STOREY COMMERCIAL BUILDING P2
WITHOUT THE PRIOR

MASTER PLUMBER
W R IT TE N C ON S E N T FR OM
T H E A R C H I T E C T
- R A 5 4 5
1477 IBAYO ST., MALINTA, VALENZUELA CITY 7
LMB Form no. GSD C-3

TECHNICAL DESCRIPTION N LOCATION


LOT 51
LOT 2747-D-7-C PSD-00-87898 8 -B-3
LINES BEARINGS DISTANCES
PLAN
4 OF LOT 518-B, (LRC) PSD-6169
1-2 N 35°12' W 18.50 M. 3
2-3 N 57°55' E 11.55 M. AS PREPARED FOR
3-4 N 80°50' E 01.94 M.
4-5 S 42°33' E 03.80 M. SPS. MANUEL EDGAR & TERESA
-A

LO
ELEUTERIA QUIRANTE
5-6 S 37°14' E 09.63 M. 18
T5

T
5
LO

51
6-7 S 35°49' E 03.50 M.

8-
B-
7-1 S 54°23' E 14.15 M. SITUATED IN THE

3
TE
ILN
I ES
:17°53W
' 1,344
.2MF
.ROM
LM. 1.5M
, ALN
I TAESTATE BRGY./DISTRICT OF: MALINTA
MUN./CITY OF: VALENZUELA
PROVINCE OF: METRO MANILA
ISLAND OF: LUZON
CONTAINING AN AREA OF: 250 SQ.M.
ZONE NO.
PPCS-PTM/PRS 92
2
BEARINGS : TRUE
SCALE 1: 100
0 1 2 3 4 5 10 m.

C E R T I F I C A T I O N

H
E R IE B
CYERF
TA
Y
R
TH
S
IU
A
T
IS
A
H
TE
N
IC
D
ORR
ECT
P LA L
O
R
N
P
(O
S
C
F
LO
P
D
6
F
1
)B
5
L
9
O
-8
,TTTEB
DA
S
ED
F
RO M THT
EC HC
NDA
IL
ES
CP
R
O
T
IA
N
P
PE
AN
T
R
HG
IC
E
OP
O
YF
N
T
A
W
O
9
L
V
TP
E
5
S
IC
8
-T
R
.H.IE
SEN TET
DO
M B
EY
TH OEW N ER .

FEBRUAR
2Y
0
138
,
Date prepared
GEODETIC ENGINEER
Reg. Cert. No. Date
-D

License No. Date


518

7
T

Republic of the Philippines


LO

Department of Environment and Natural Resources

VERIFICATION

MALINTA I certify that this survey plan is verified and found to


conform with survey returns/records on file in this office.
THIS PLAN SHALL NOT BE USED FOR LAND RE -
D .
MIRANDA COMPOUND ZA R GISTRATION
PLA
U A
PAD A. P
A B L
T

O ST
TRO
EE

EZ .
R

AND
ST

DATE
DE CAS

N
HER O
O

NGC PURPOSE
G

. TO
TIA

TAN

P 1
B-
A
N

ST. LOUIS K OS
SA

GKE

COMPOUND
P. S
ANT 8-
I.

ONG 51
STR
V.

MOR T
GO

STO
AGO
LO
E

A
SN. JULIAN
ET

SN. R IA CHIEF, REGIONAL SURVEYS DIVISION


.M A
STA ITA
SAIN

LIL . R
AC STA R
T JU

PILA Date Submitted


N
DE

CIO
BUE

ADDITIONAL INFORMATION AFTER DATE OF APPROVAL


OLA
ST.

N S AL
NAV

CO SAM
NI
ENT

OR A
MAP

1
URA

K
LE

VICINITY MAP VERIFICATION FEE


Paid Under
O.R. No.
NOT TO SCALE
Date :
Lot/s Corners S