IBC 1009.5
STAIRWAY HEADROOM IBC 1009.7.5
NOSING AND RISER PROFILE
IBC 1009.7.2
CONVENTIONAL STAIRWAY
IBC 1009.8
CURVED LANDINGS
IBC 1009.8
STAIRWAY LANDINGS
IBC 1009.12
SPIRAL STAIRWAYS
Winder treads are only permitted in other than R-3 or within R2 for
means of egress stairways provided they are curved or spiral
stairways [IBC 1009.7.3].
10
IBC 1009.11
CURVED STAIRWAYS
IBC 1009.7.2
WINDERS USED FOR CURVED STAIRWAY Sheet 1 of 4
SCPDC COMMERCIAL STAIR / GUARD / HANDRAIL HANDOUT
IBC 1010.6
DOOR SWING OVER RAMP LANDINGS
IBC 1010.7
RAMP LANDINGS IBC 1012.3.2
DIMENSIONAL HANDRAILS (TYPE II)
IBC 1010.10
RAMP EDGE PROTECTION IBC 1012.3.1
TYPE I HANDRAILS
Gripping surface shall be continuous, without interruption by newel
post or other obstruction except within dwelling units at turn or landing
and use of volute, turnout, starting easing or starting newel over the
lowest tread.
IBC 1012.4
HANDRAIL CONTINUITY
IBC 1012.2
HANDRAIL HEIGHT
IBC 1013.2
GUARDRAILS
Sheet 2 of 4
Handrails shall be continuous between flight of stairs
IBC 1008.1.6
LENGTH OF LANDINGS AT DOORS
Ramp
IBC 1012.6
STAIRWAY HANDRAIL EXTENSIONS
IBC 1012.8
HANDRAIL PROJECTIONS
IBC 1013.4
GUARD OPENING LIMITATIONS
IBC 1013.4
GUARD OPENING LIMITATIONS
NOTE: Exception to the 4 & 6-in sphere requirement, where elevated walking surfaces IBC 1008.1.6
for access to electrical, mechanical or plumbing systems or equipment and in areas
WIDTH OF LANDINGS AT DOORS
that are not open to the public within occupancies in Group I-3, F, H or S (ie. prisons,
jails, industrial or storage), guards shall not have openings which allow passage of a IBC 1012.7
sphere 21 inches in diameter. HANDRAIL CLEARANCE
Sheet 3 of 4
Guard Rail for foot of
IBC 1028.14.2
Guards in front
of seating Guardrail for cross aisle shall be in
IBC 1013.4 exception #5 accordance with IBC 1013 (42" etc.)
where greater than 30" from floor or
grade below.
IBC 1028.14.1
ASSEMBLY CROSS AISLE GUARDS
Min 36" if foot of aisle is equal to or less than 30" above the floor or grade below [IBC 1028.14.3] Not applicable if guard is required to be 42" in height
IBC 1028.14
ASSEMBLY SEATING GUARDS
IBC 1028.14.3
ASSEMBLY AISLE GUARDS
Sheet 4 of 4