Standardized pumps
The European Standard EN733*1 complied
Mechanical seal
Complied with EN 12756*2
Various material option available
Model GS
EN733*1 : End-suction centrifugal pumps, rating with 10 bar with bearing bracket - Nominal duty point,
main dimensions, designation system
EN 12756*2 : Mechanical seals. Principal dimensions, designation and material codes
ErP*3 : Eco-design requirements of Energy-related Products
2 Simple Maintenance
• Back pull-out structure enables disassembly and inspection without
removal of suction and discharge piping.
• Shield bearings eliminate need for adding or exchanging lubricating oil.
• Shaft seal flushing and quenching piping not required for the standard
application.
• Air-bleeding not required.
• Simplified bearings and shaft seal enable easy assembly.
3 Pump Specifications
• Maximum operating pressure: 25 bar
• Liquid temperature range expansion:-25°C to 140°C
• Compatible with multiple flange standards.
• Able to meet customer specifications with many combinations of shaft
seals and materials.
4 International Standards
• Pump dimensions adopt EN733
• Mechanical seal adopts EN12756
• Protector fitted in accordance with EN294.
Model GS
Casing Material: Cast Iron
Description
Liquid temperature -10℃ to 140°C
Up to 16bar( 1.6MPa)/ for standard flange DIN-PN16
Max. Operating Pressure
Up to 14bar(1.4MPa)/ for standard flange JIS10K
Flange Standard EN1092-2 , JIS B 2239
Impeller Closed
Shaft seal Mechanical Seal , Gland Packing
Construction
Flushing N/A , Self , External
Ball bearing Shield ball bearing (grease lubrication)
Casing Cast iron
Cast iron or Ductile cast irons (* 1)
Impeller
Bronze , 304 Stainless steel
Material (* 3) Shaft Cr.steel , Duplex stainless steel (* 2)
Case wear ring Bronze , Cast iron
Shaft sleeve N/A , 304 Stainless steel (Gland packing or some mechanical seal)
O-ring NBR , FKM , EPDM
Model GS
Casing Material: Ductile Cast Irons (Larger than pump model 100X80)
Description
Liquid temperature -10℃ to 140°C
Up to 25bar( 2.5MPa)/ for standard flange DIN-PN25
Max. Operating Pressure
Up to 25bar(2.5MPa)/ for standard flange JIS20K
Flange Standard EN1092-2 , JIS B 2239
Impeller Closed
Shaft seal Mechanical Seal
Construction
Flushing N/A , Self , External
Ball bearing Shield ball bearing (grease lubrication)
Casing Ductile cast irons
Cast iron or Ductile cast irons (* 1)
Impeller
Bronze , 304 Stainless steel
Material (* )
3
Shaft Cr.steel , Duplex stainless steel (* 2)
Case wear ring Bronze , Cast iron
Shaft sleeve N/A , 304 Stainless steel (in case of some mechanical seal)
O-ring NBR , FKM , EPDM
Model GSS
Casing Material: Stainless Steel
Description
Liquid temperature -25℃ to 140°C
Up to 16bar( 1.6MPa)/ for standard flange DIN-PN16
Max. Operating Pressure
Up to 14bar(1.4MPa)/ for standard flange JIS10K
Flange Standard EN1092-1 , JIS B 2220
Impeller Closed
Shaft seal Mechanical Seal , Gland Packing
Construction
Flushing N/A , Self , External
Ball bearing Shield ball bearing (grease lubrication)
Casing 304 Stainless steel , 316 Stainless steel
Impeller 304 Stainless steel , 316 Stainless steel
Shaft Duplex stainless steel (* 1)
Material (* 2) Case wear ring 316 Stainless steel
N/A , 304/316 Stainless steel
Shaft sleeve
(in case of Gland packing or some mechanical seal)
O-ring FKM , EPDM
BUILDING
・Air conditioning-District heating & cooling
General water supply
Brine (antifreeze liquid)
Hot water circulation
High pressure booster
WATER SUPPLY
・Water supply duties for municipalities
・Irrigation
・Drainage clean water
・Fire fighting protection
・Swimming pool
GENERAL INDUSTRY
・Semiconductor Industry
Pure water
・Food Industry
General water (Cooling water, Recycling water, Filtered water)
CIP (Cleaning In Place),
・Pulp and Paper Industry
White water (below pulp conc.of 0.3%)
・Automotive Industry
Water (without slurry)
・Steel Industry-Non-ferrous metals Industry
Coolant
Cooling Water
・Garbage incineration
Cooling Water
Deaerater
Condensate water
・Other Chemical
・Diesel Oil, Fuel Oil, Lubricants Oil
GS 32 - 125
DISCHARGE NOZZLE,
NOMINAL SIZE IN MILLIMETER
MODEL,
-GS (CAST IRON OR DUCTILE CAST IRON CASING)
-GSS (STAINLESS STEEL CASING)
(*1) The letter “L” following the impeller classification code indicates different bearing designs. To give
an example, GS80-315 and GS80-315L have different bearing designs and shaft size.
(*2) The letter “.1” following the impeller classification code indicates different casing and impeller
designs. To give an example, GS32-125 and GS32-125.1 have different casing and impeller
designs from one another.
Pump model
200
150
160
37 132
45 55 200
30
55 50-315 75
90 80-315L
40-315 75 110
132 160
22 45 65-315 110 125-315
100 37
55 90 100-315L 160 200
37 90
45 110 220
45
32-250 18.5 18.5 22 30 50-250 55
80-250 90 110 160
11 200
40-250 65-250
Tota l He a d (m )
100-250 125-250L
7.5 15 30 55
15 75
37 45
22 30 90
75 110 132
45 90 200
5.5 7.5 11 15 220
18.5 37 55 75 90 160
50 32-200 50-200 65-200 37
132
4
40-200 30 30
80-200 100-200
110 150-250
3 32-200.1 11 22
125-200
5.5 7.5 18.5 22 30
40 7.5 15 55 110
11
4 18.5 22 45 75 90
3
5.5 55
37
32-160.1 5.5 7.5 11 15 45
150-200
7.5
30
18.5 22
2.2
32-160 40-160 50-160 65-160 75
37
1.5 11 15 18.5 30 55
4 5.5
3 4 11
7.5
80-160 30
37 45
20 1.5 2.2 3 4
5.5 7.5 15 100-160
11
32-125.1 3 40-125
4 50-125 65-125
22
15 11 18.5
Capacit y ( m /h ) 3
100
315 375
37 45 75 200-500 250
55
30
125-500 150-500 160 200
132 220
110
160
90 90
45
75
50 15 18.5 22 30 37
45 125-400
75
11
80-400 37
75 132
160 200
55
40 100-400
37
45
55 150-400
90
200-400
11 30 110
55 75
Tot a l He ad (m )
50-315
30
22
4 7.5 80-315 90
3 0.55
2
4 5 10 20 30 40 50 100 200 300 400 500 1000 2000
C a pa c i ty ( m /h) 3
Note1 : The values inside the broken lines are motor output(kW) in case of density 1.0kg/ℓ and viscosity 1.0mPa・s.
Note2 : The indicated motor output(kW) value includes the following safety margins ;
up to 7.5kW : 15%
11kW and above : 10%
Note3 : When selecting a pump , NPSH Av. should have a safety margin of at least 0.5m from NPSH Re.
Pump model
200
150
75
30
37 45 55
50-315 80-315L 160
90
132
65-315
100
110 110
22 55
30 75 90
37
80
45
32-250 50-250 55
40-250 30 65-250
7.5 11
15
15
18.5 22 45 80-250 90
37 75
Coming
Tota l Head ( m )
55
60
30 45
5.5 Soon
7.5 32-200 40-200
5.5 11
11 15
18.5
22
65-200 80-200
4 30
3 32-200.1 15 50-200 22 37
45
40 7.5 7.5
11
18.5 30
3
32-160.1 5.5
7.5
30
4 5.5 11 15 18.5
40-160 11
50-160 65-160
2.2 32-160 5.5
15 22
18.5 30
4 7.5 11
3
80-160
7.5
20 3
5.5
15
2.2 7.5
1.1 4
0.75
2.2
1.5 3
10 1.5
6
4 8 20 40 60 80 100 200 400 600 1000 2000
C a pa c i t y ( m / h ) 3
150
100
80
60
80-400 45
22 37
30
40 Coming
To ta l He a d ( m )
11 Soon
4 5.5 7.5 50-315 80-315
30 15 18.5
22
65-315
2.2 3 11 15
7.5
50-250
20
2.2 4
7.5
3 4 5.5
1.1
1.5 32-250 2.2 40-250 65-250 80-250
5.5 11
15
3 4 7.5
5.5
0.75
2.2
1.1 32-200 1.5
40-200 65-200 5.5
32-200.1 1.5
3 4 7.5
0.55 0.75 2.2 50-200 80-200
10
1.1 3
1.1 1.5 4
0.55 0.75
8 0.75 1.1
32-160.1 32-160 40-160 2.2 3
1.5
50-160 65-160 3
4
0.75 1.5 2.2
80-160
6
0.55 0.55 1.1 1.5
0.55
2
4 8 20 40 60 80 100 200 400 600 1000 2000
C a pa c ity ( m 3 /h)
Note1 : The values inside the broken lines are motor output(kW) in case of density 1.0kg/ℓ and viscosity 1.0mPa・s.
Note2 : The indicated motor output(kW) value includes the following safety margins ;
up to 7.5kW : 15%
11kW and above : 10%
Note3 : When selecting a pump , NPSH Av. should have a safety margin of at least 0.5m from NPSH Re.
Pump model
200
150 45
90
110
132
55 75 90
18.5
37
45 65-250 100-250L 220
15
32-250 30 30
40-250 55
100
11 22 200
22 50-250 90 160
37
45
75 80-250 110 132
45 200
80 15 22 30 37 220
160
11
18.5
40-200 45 250
32-200 50-200
45 55
80-200 90 132 125-250L
Total Head ( m)
18.5 110
30 132
5.5 7.5
32-200.1 15 65-200 75
60 11
22
30
37 45
55 100-200
90 110
132
11
15
18.5 75 125-200
5.5 7.5 22
32-160 18.5 30
30
37 45 90
110
132
4 32-160.1 11 40-160 50-160 55 55
65-160
40 3
7.5
11 22
90
1.1
4 5.5
3
15 3
8
8 20 40 60 80 100 200 400 600 1000 2000
Capacity (m /h) 3
150
as request
90 110 375
75 200 220
55 200-500
100 45 125-500
132
160 250
315
55
160 150-500
80
250
75
37 45 132
125-400 315
30 75 90 110 132 250
80-400 132 220 375
60
18.5 22 110
100-400 90
150-400L 200
160
55 75 200-400
50
22
15 18.5 45
11 110
30 37 160
To t al H e a d ( m)
90
7.5 15
50-315 22 132
40-315 18.5
80-315 125-315
40
30 132
5.5
37 45 150-315
4 11 65-315 55
75
11
15
18.5 22 100-315 37 45
75
30 55
11
30 3
40-250 50-250 15 45
2.2 32-250
4
7.5 7.5 65-250 80-250 18.5
22
22
30
125-250 55
4 5.5 75
37
3
5.5 7.5 11 11 15 100-250 45
30
15 18.5 22 150-250
20
2.2 4 7.5 37
1.5 15
5.5
32-200 40-200 65-200 80-200 15 18.5
30
18.5
1.1
32-200.1 3 50-200 11
22
15
2.2
0.75
5.5
7.5 100-200
1.5 3 4
4
5.5
11
125-200
15 18.5
7.5 22
0.75 1.1
32-160.1 1.5
1.5
2.2
3
3 4
5.5
11 150-200
0.55 5.5
32-160 50-160
10
15
1.1
40-160 65-160
1.1 7.5
0.75
2.2 3 80-160 11
8 1.1
4
7.5
0.75 5.5
1.5
100-160
6
2.2
0.75 40-125 65-125
32-125.1 50-125
3 3
4
32-125
5
2.2
0.75 1.1
1.5
0.55 0.55
4
0.75
0.55
3
6 8 10 20 30 40 60 80 100 200 300 400 600 1000 2000
C a pa c ity ( m / h) 3
Note1 : The values inside the broken lines are motor output(kW) in case of density 1.0kg/ℓ and viscosity 1.0mPa・s.
Note2 : The indicated motor output(kW) value includes the following safety margins ;
up to 7.5kW : 15%
11kW and above : 10%
Note3 : When selecting a pump , NPSH Av. should have a safety margin of at least 0.5m from NPSH Re.
Pump model
200
150
75
32-250 30 40-250
90
15 18.5 30 45 55 65-250
100
11 22
22 37
50-250 55 Coming
37
45 80-250
45 75 110 Soon
80
90
18.5
11 32-200 18.5 40-200 30
30
45 55 75
15
7.5 22
37 65-200 80-200 90
50-200
Tot a l H e a d ( m )
32-200.1 55
60
5.5 11 15
37
22 45
30
5.5
32-160.1 11 18.5
7.5 15 30
11
37
4
40-160 50-160 65-160
40 3
32-160
7.5
11 22
45
7.5 15 18.5 30
5.5
80-160
30 5.5 7.5 11 15
15 18.5
32-125.1 4 5.5
40-125 50-125 22
3 5.5 11
2.2
32-125 65-125 18.5
20 4 7.5
11
3 4
1.5
5.5
15 2.2
3
10
8
6
4 8 20 40 60 80 100 200 400 600 1000 2000
C a p a c i t y ( m /h) 3
150
100
80 45
80-400
75
37 55
30
60 22
15
22 Coming
50-315 Soon
11
18.5 80-315 37
40
5.5 7.5
65-315 30
30
Tota l Hea d ( m)
5.5 22
15 18.5 22
11 18.5
30 3 4
50-250 11
15
2.2 32-250 4 40-250 7.5 7.5
65-250 80-250 22
1.5 3 5.5 15 18.5
7.5 11
5.5
20
4
1.5 32-200 3
40-200 65-200
32-200.1 2.2
11
1.1 2.2 3
50-200 80-200
15
1.5
3 4 5.5
5.5 7.5
0.75
1.1 1.5 2.2
0.55 32-160.1 32-160 40-160 3 4 5.5
65-160
10 1.1 1.1
50-160
2.2 7.5
0.75
3
80-160
8
4
1.5
1.1 2.2
0.75 3
0.55 0.75 40-125 50-125 65-125
6
2.2 3
32-125.1 32-125 0.75
0.55
1.1 1.5
0.55
4
0.75
2
4 8 20 40 60 80 100 200 400 600 1000 2000
C a p a c i t y ( m 3 /h)
Note1 : The values inside the broken lines are motor output(kW) in case of density 1.0kg/ℓ and viscosity 1.0mPa・s.
Note2 : The indicated motor output(kW) value includes the following safety margins ;
up to 7.5kW : 15%
11kW and above : 10%
Note3 : When selecting a pump , NPSH Av. should have a safety margin of at least 0.5m from NPSH Re.
φdn1
u2
h2
t
SHAFT END
h1
d
A N×φd
DRAIN s1 b m2 D2
WITH PLUG
m1 dn
s2
T
n3 w
n2 D1
n1 FLANGE
Flange Dimension
Material: Cast Iron
Flange Standard: EN PN16 Unit: mm Flange Standard: JIS 10K Unit: mm
Suction flange Discharge flange Suction flange Discharge flange
MODEL MODEL
dn1 A D1 D2 T N d dn2 A D1 D2 T N d dn1 A D1 D2 T N d dn2 A D1 D2 T N d
GS32 50 165 125 99 20 4 19 32 140 100 76 18 4 19 GS32 50 155 120 96 20 4 19 32 135 100 76 20 4 19
GS40 65 185 145 118 20 4 19 40 150 110 84 18 4 19 GS40 65 175 140 116 22 4 19 40 140 105 81 20 4 19
GS50 65 185 145 118 20 4 19 50 165 125 99 20 4 19 GS50 65 175 140 116 22 4 19 50 155 120 96 20 4 19
GS65 80 200 160 132 22 8 19 65 185 145 118 20 4 19 GS65 80 185 150 126 22 8 19 65 175 140 116 22 4 19
GS80 100 220 180 156 24 8 19 80 200 160 132 22 8 19 GS80 100 210 175 151 24 8 19 80 185 150 126 22 8 19
GS100 125 250 210 184 26 8 19 100 220 180 156 24 8 19 GS100 125 250 210 182 24 8 23 100 210 175 151 24 8 19
GS125 150 285 240 211 26 8 23 125 250 210 184 26 8 19 GS125 150 280 240 212 26 8 23 125 250 210 182 24 8 23
GS150 200 340 295 266 30 12 23 150 285 240 211 26 8 23 GS150 200 330 290 262 26 12 23 150 280 240 212 26 8 23
GS200 250 405 355 319 32 12 28 200 340 295 266 30 12 23 GS200 250 400 355 324 30 12 25 200 330 290 262 26 12 23
GS80 100 235 190 156 19 8 23 80 200 160 132 19 8 19 GS80 100 225 185 160 24 8 23 80 200 160 132 22 8 23
GS100 125 270 220 184 19 8 28 100 235 190 156 19 8 23 GS100 125 270 225 195 26 8 25 100 225 185 160 24 8 23
GS125 150 300 250 211 20 8 28 125 270 220 184 19 8 28 GS125 150 305 260 230 28 12 25 125 270 225 195 26 8 25
GS150 200 360 310 274 22 12 28 150 300 250 211 20 8 28 GS150 200 350 305 275 30 12 25 150 305 260 230 28 12 25
GS200 250 425 370 330 24.5 12 31 200 360 310 274 22 12 28 GS200 250 430 380 345 34 12 27 200 350 305 275 30 12 25
32-125.1 100 28 30
112 140 190 140
32-125 100 28 27
32-160.1 100 29 28
80 132 160 50 100 70
32-160 50 32 360 1/4B 110 260 M12 M12 24 50 27 8 7 100 29 28
240 190
32-200.1 100 39 38
160 180
32-200 100 39 37
125-500 180 670 375 450 550 450 140 500 M16 48 51.5 14 9 140 365
150-200 470 355 340 32 80 35 10 140 154
280 500 400
150-250 375 3/8B 140 171
110 M12 8
150-315, 2) 160 530 400 370 42 45 12 140 225
200 150 100 200 150 M20 future
150-400 315 110 140 339
450 550 450
150-400L 1/2B 48 51.5 14 9 140 363
670 140 500 M16
150-500 180 375 560 60 64 18 11 180 491
200-400 180 670 385 560 140 500 M20 60 110 64 18 11 180 508
250 200 1/2B 100 315 250 660 560 M16 future
200-500 200 820 435 630 160 630 M24 75 125 79.5 20 12 180 645
1) Dimension to be considered by the manufacturer in respect of removal of inner parts of the Pump. The dimension X must not be idential with the distance between the shafts of the pump and the driving
machine. The given dimension considers the use of flexible shaft couplings with spacer. The gap is necessary for the withdrawal of the rotor toward the driven side.
2) h1 is 35mm higher than EN733 dimension.
φdn1
h1
BY BJ
BW BN1 BM1 BN2
φdn1
h1
BY BJ
BW BN1 BM1 BM2 BN2
ANCHOR BOLT HOLES COUPLING
n×Fd GUARD
Mechanical seal
Type
001 107-1 193-1 021 018 120-1 111 120-2 051 093 056 053 120-5 031
048-1 048-2 137-2 137-1 193-2 039-1 107-2 115 042 120-4 010 095 120-3 039-2
039-1 K EY 1 120-1 B OL T -
039-2 K EY 1 120-2 B OL T 6
GLAND PACKING
Type
001 107-1 117 193-1 021 090 018 120-1 120-2 124 051 093 056 053 120-5 031
048-1 048-2 137-2 137-1 193-2 039-1 107-2 115 119 041 091 120-4 010 095 120-3 039-2
039-2 K EY 1 120-1 B OL T -
(*1) Except pumps model GS100-400, 125-400, 125-500, 150-400, 150-500, 200-400 and 200-500,
impellers made of cast iron are applied for all pumps.
(*2) Impellers made of ductile cast iron are applied only the pumps model GS100-400, 125-400, 125-500,
150-400, 150-500, 200-400 and 200-500.
(*3) Duplex stainless steel is used for wetted part only. The remaining atmospheric side of shaft is made of
carbon steel.
(*4) Deep groove ball bearing,single row / Vacuum degassed steel
(*5) Elastomer bellows seal
(*6) O ring/Spring
(* ) The components which constitute the gland packing pump are these parts instead of P/N 018, 042