Académique Documents
Professionnel Documents
Culture Documents
One
Non-volatile Trip
Transmission Electro-
memory (static Runs
Transmission Control Hydraulic Control
P0603 or dynamic) = TRUE Boolean Continousl
Module (TCM) Module Long-Term
checksum failure y
Memory Reset
at Powerup
One
Transmission Electro- Trip
RAM Read/Write
Transmission Control Hydraulic Control Fail
P0604 Failure (Single = TRUE Boolean >= 5
Module (TCM) Module Random Counts
Word)
Access Memory
Sample
= 16
Counts
One
Transmission Electro- TCM Non- Trip
Runs
Transmission Control Hydraulic Control Volatile Memory
P062F = TRUE Boolean Continousl
Module (TCM) Module Long Term bit Incorrect flag
y
Memory Performance at Powerdown
One
The HWIO Trip
reports a low
Actuator Supply Fail
High Side Driver 1 P0658 voltage (open or = TRUE Boolean >= 3
Voltage Circuit Low Counts
ground short)
error flag
out Sample
5
of Counts
One
TCM Run crank Trip
Ignition Switch active (based on
Transmission Control
P2534 Run/Start Position voltage = FALSE Boolean
Module (TCM)
Circuit Low thresholds
below)
Ignition Voltage
Fail
High Hyst (run
Counts
crank goes true 5 Volts >= 280
(25ms
when above this
loop)
value)
Ignition Voltage
Sample
Low Hyst (run
Out Counts
crank goes false 2 Volts 280
of (25ms
when below this
loop)
value)
Sample
= 16
Counts
Ignition Voltage Lo >= 9 Volts
Ignition Voltage Hi <= 18 Volts
Fail One
Transmission Electro- Case Trip
Transmission 1
Hydraulic Control Substrate Fail Time
Control Module P0634 >= 144 ºC >= 5
Module Internal Temperature (Sec)
(TCM)
Temperature Too High
Fail
Substrate Fail Time
Case >= 50 ºC >= 2
Temperature (Sec)
2
One
The HWIO reports Trip
High Side Actuator Supply a low voltage
P0658 = TRUE Boolean >= 3 Fail Counts
Driver 1 Voltage Circuit Low (open or ground
short) error flag
out Sample
5
of Counts
Test
Failed
This Key
P0658 Status is not =
On or
Fault
Active
Two
Refer to Trips
Table
TCM Internal Temp
Transmission If transmission oil 19 in
(substrate) Sensor
Control Module P0667 temp to substrate > supporti ºC
Circuit
(TCM) temp ǻ ng
Range/Performance
docume
nts
Refer to
Table
If TCM substrate 20 in
temp to power up > supporti ºC
temp ǻ ng
docume
nts
Both conditions
Fail Counts
above required to
>= 3000 (100ms
increment fail
loop)
counter
Note: table
reference temp = Sample
to the median temp Out Counts
3750
of trans oil temp, of (100ms
substrate temp and loop)
power up temp.
Non-continuous
Pass
(intermittent) fail
Counts
conditions will >= 700
(100ms
delay resetting fail
loop)
counter until
Sample
Out Counts
875
of (100ms
loop)
Clutch
Clutch hydraulic Hydraulic
pressure Air Purge
Event
CeTFTD_
Clutch used to exit
= e_C3_Rat
brake torque active
lEnbl
The above clutch
pressure is greater
>= 600 kpa
than this value for
one loop
Set Brake Torque
Active FALSE if
>= 20 Sec
above conditions are
met for:
Two
TCM internal CeTFTI Trips
Transmission
temperature Type of Sensor _e_Volt
Control Module P0668 =
(substrate) thermistor Used ageInve
(TCM)
failed at a low voltge rseProp
Either condition
Fail Timer
above will satisfy >= 60
(Sec)
the fail conditions
Ignition Voltage Lo >= 9 Volts
Ignition Voltage Hi <= 31.99023 Volts
Engine Speed Lo >= 400 RPM
Engine Speed Hi <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
Test
Failed
This Key
P0668 Status is
On or
Fault
Active
Two
TCM internal CeTFTI Trips
Transmission
temperature Type of Sensor _e_Volt
Control Module P0669 =
(substrate) thermistor Used ageInve
(TCM)
failed at a high voltage rseProp
If TCM Substrate
Temperature
Sensor = Direct >= -254 ºC
Proportional and
Temp
MH8/T76 SECTION Page 9 of 276 2 OF 3 SECTIONS
MH8/T76 SECTION
12 OBDG04 Transmission Diagnostics 2 OF 3 SECTIONS
Component/ Fault Monitor Strategy Malfunction Threshold Secondary Enable Time Mil
System Code Description Criteria Value Malfunction Conditions Required Illum.
If TCM Substrate
Temperature
Sensor = Indirect <= -254 ºC
Proportional and
Temp
Either condition
Fail Timer
above will satisfy >= 60
(Sec)
the fail conditions
Ignition Voltage Lo >= 9 Volts
Ignition Voltage Hi <= 31.99023 Volts
Engine Speed Lo >= 400 RPM
Engine Speed Hi <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
Test
Failed
This Key
P0669 Status is
On or
Fault
Active
For Hybrids, below
conditions must also
be met
Estimated Motor
>= 0 kW
Power Loss
Estimated Motor
Power Loss greater >= 0 Sec
than limit for time
Lost Communication
with Hybrid Processor = FALSE
Control Module
Estimated Motor
= FALSE
Power Loss Fault
ECM: None
Two
Refer to Trips
Table
Transmission TCM Power-up Temp If TCM power-up 20 in
Control Module P06AC Sensor Circuit temp to substrate > supporti ºC
(TCM) Range/Performance temp ǻ ng
docume
nts
Refer to
Table
If transmission oil 18 in
temp to power up > supporti ºC
temp ǻ ng
docume
nts
Both conditions
Fail Counts
above required to
>= 3000 (100ms
increment fail
loop)
counter
Note: table
reference temp = Sample
to the median temp Out Counts
3750
of trans oil temp, of (100ms
substrate temp and loop)
power up temp.
Non-continuous
Pass
(intermittent) fail
Counts
conditions will >= 700
(100ms
delay resetting fail
loop)
counter until
Sample
Out Counts
875
of (100ms
loop)
MH8/T76 SECTION Page 11 of 276 2 OF 3 SECTIONS
MH8/T76 SECTION
12 OBDG04 Transmission Diagnostics 2 OF 3 SECTIONS
Component/ Fault Monitor Strategy Malfunction Threshold Secondary Enable Time Mil
System Code Description Criteria Value Malfunction Conditions Required Illum.
Clutch
Clutch hydraulic Hydraulic
pressure Air Purge
Event
CeTFTD_
Clutch used to exit
= e_C3_Rat
brake torque active
lEnbl
Estimated Motor
Power Loss greater >= 0 Sec
than limit for time
Lost Communication
with Hybrid Processor = FALSE
Control Module
Estimated Motor
= FALSE
Power Loss Fault
ECM: None
Two
Refer to Trips
Table
Transmission
Trans Fluid Temp If transmission oil 19 in
Fluid
P0711 Sensor Circuit temp to substrate > supporti ºC
Temperature
Range/Performance temp ǻ ng
Sensor (TFT)
docume
nts
Refer to
Table
If transmission oil 18 in
temp to power up > supporti ºC
temp ǻ ng
docume
nts
Both conditions
Fail Counts
above required to
>= 3000 (100ms
increment fail
loop)
counter
Note: table
reference temp = Sample
to the median temp Out Counts
3750
of trans oil temp, of (100ms
substrate temp and loop)
power up temp.
Non-continuous
Pass
(intermittent) fail
Counts
conditions will >= 700
(100ms
delay resetting fail
loop)
counter until
Clutch
Clutch hydraulic Hydraulic
pressure Air Purge
Event
CeTFTD_
Clutch used to exit
= e_C3_Rat
brake torque active
lEnbl
The above clutch
pressure is greater
>= 600 kpa
than this value for
one loop
Set Brake Torque
Active FALSE if
>= 20 Sec
above conditions are
met for:
Test
Failed
This Key
P0711 Status is
On or
Fault
Active
Two
Transmission CeTFTI Trips
Transmission fluid
Fluid Type of Sensor _e_Volt
P0712 temperature thermistor =
Temperature Used ageInve
failed at a low voltage
Sensor (TFT) rseProp
If Transmission
Fluid Temperature
Sensor = Direct <= 254 ºC
Proportional and
Temp
If Transmission
Fluid Temperature
Sensor = Indirect >= 254 ºC
Proportional and
Temp
Either condition
Fail Time
above will satisfy >= 60
(Sec)
the fail conditions
Ignition Voltage Lo >= 9 Volts
Ignition Voltage Hi <= 31.99023 Volts
Engine Speed Lo >= 400 RPM
Engine Speed Hi <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
Test
Failed
This Key
P0712 Status is
On or
Fault
Active
For Hybrids, below
conditions must also
be met
Estimated Motor
>= 0 kW
Power Loss
Estimated Motor
Power Loss greater >= 0 Sec
than limit for time
Lost Communication
with Hybrid Processor = FALSE
Control Module
Estimated Motor
= FALSE
Power Loss Fault
ECM: None
Two
Transmission CeTFTI Trips
Transmission fluid
Fluid Type of Sensor _e_Volt
P0713 temperature thermistor =
Temperature Used ageInve
failed at a high voltage
Sensor (TFT) rseProp
If Transmission
Fluid Temperature
Sensor = Direct >= -254 ºC
Proportional and
Temp
If Transmission
Fluid Temperature
Sensor = Indirect <= -254 ºC
Proportional and
Temp
Either condition
Fail Time
above will satisfy >= 60
(Sec)
the fail conditions
Ignition Voltage Lo >= 9 Volts
Ignition Voltage Hi <= 31.99023 Volts
Engine Speed Lo >= 400 RPM
Engine Speed Hi <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
Test
Failed
This Key
P0713 Status is
On or
Fault
Active
ECM: None
One
Transmission Transmission Input
Input Speed Sensor Fail Time Trip
Input Speed P0716 Speed Sensor >= 1350 RPM >= 0.8
Performance (Sec)
Sensor (TISS) Drops
The previous
requirement has been >= 0 Sec
satisfied for
Throttle Position
= TRUE Boolean
Signal Valid
Engine Torque Signal
= TRUE Boolean
Valid
Ignition Voltage >= 9 Volts
Ignition Voltage <= 31.99023 Volts
Fail One
Transmission
Input Speed Sensor Case Transmission Input Fail Time Trip
Input Speed P0717 < 50 67 RPM >= 4.5
Circuit Low Voltage 1 Speed is (Sec)
Sensor (TISS)
Fail
Case When P0722 DTC
2 Status equal to Controller uses a
Test Failed and < 1000 RPM single power supply = 1 Boolean
Transmission Input for the speed sensors
Speed is
One
Transmission Transmission Trip
Output Speed Sensor Fail Time
Output Speed P0722 Output Speed <= 35 RPM >= 4.5
Circuit Low Voltage (Sec)
Sensor (TOSS) Sensor Raw Speed
Test
Failed
This Key
P0722 Status is not =
On or
Fault
Active
Transmission Input
= TRUE Boolean
Speed Check
Engine Torque Check = TRUE Boolean
Throttle Position >= 8.000183 Pct
Transmission Fluid
>= -40 ºC
Temperature
Disable this DTC if
= 1 Boolean
the PTO is active
Engine Torque Signal
= TRUE Boolean
Valid
Throttle Position
= TRUE Boolean
Signal Valid
Ignition Voltage is >= 9 Volts
Ignition Voltage is <= 31.99023 Volts
Engine Speed is >= 400 RPM
Engine Speed is <= 7500 RPM
Enable_Flags
Defined Below
Engine Torque
Condition 1
Range
shift
Range Shift Status ENUM
complete
d
OR
Transmission Range Park or
=
is Neutral
Engine Torque is >= 8191.75 N*m
Engine Torque is <= 8191.75 N*m
Engine Torque
Condition 2
Engine Torque is >= 30 N*m
Engine Torque is <= 8191.75 N*m
----------------------
The Transmission
Input Speed (TIS)
Check is TRUE, if
either of the two
following conditions
are TRUE
Powertrain Brake
= TRUE Boolean
Pedal is Valid
One
Transmission Transmission Trip
Output Speed Sensor Enable
Output Speed P0723 Output Speed >= 105 RPM >= 0
Circuit Intermittent Time (Sec)
Sensor (TOSS) Sensor Raw Speed
Output
Speed Drop
Output Speed Drop > 1000 RPM >= 3 Recovery
Fail Time
(Sec)
AND
No Change in
Transfer Case Range >= 5 Seconds
(High <-> Low) for
Test
Failed
This Key
P0723 Status is not =
On or
Fault
Active
Disable this DTC if
= 1 Boolean
the PTO is active
Ignition Voltage is >= 9 Volts
Ignition Voltage is <= 31.99023 Volts
Engine Speed is >= 400 RPM
Engine Speed is <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
Enable_Flags
Defined Below
Transmission_Input_
Speed_Enable is
TRUE when either
TIS Condition 1 or
TIS Condition 2 is
TRUE:
TIS Condition 1 is
TRUE when both of Enable
the following >= 0 Time
conditions are (Sec)
satsified for
Input Speed Delta <= 4095 RPM
Raw Input Speed >= 500 RPM
TIS Condition 2 is
TRUE when ALL of
the next two
conditions are
satisfied
Input Speed = 0 RPM
A Single Power
Supply is used for all = TRUE Boolean
speed sensors
Powertrain Brake
= FALSE Boolean
Pedal Applied is
----------------------
Neutral_Range_Enab
le is TRUE when any
of the next 3
conditions are TRUE
Transmission Range
= Neutral ENUM
is
Range_Disable is
TRUE when any of
the next three
conditions are TRUE
Transmission Range
= Park ENUM
is
Park/Rev
Transmission Range erse
= ENUM
is Transiton
al
ON (Fully
Input Clutch is not = ENUM
Applied)
----------------------
Neutral_Speed_Enab
le is TRUE when All
of the next three > 1 1.5 Seconds
conditions are
satsified for
Transmission Output
> 100 130 RPM
Speed
The loop to loop
change of the
< 500 125 RPM
Transmission Output
Speed is
Table
Based
Time
Please
Time since a driven Refer to
range (R,D) has been >= Table 21 Sec
selected in
supportin
g
document
s
Transmission Output
Speed Sensor Raw >= 500 RPM
Speed
Torque Two
TCC System Stuck Enable
Converter P0741 TCC Pressure >= 500 Kpa >= 2 Trips
OFF Time (Sec)
Clutch (TCC)
Either Condition
(A) or (B) Must be
Met
Refer to
Table 1
in
(A) TCC Slip Error Fail Time
>= Support RPM >= 5
@ TCC On Mode (Sec)
ing
Docum
ents
If Above
Conditions Have
TCC Stuck
been Met, and Fail
>= 62 Off Fail
Timer Expired,
Counter
Increment Fail
Counter
On or
TCC Mode =
Lock
Ignition Voltage Lo >= 9 Volts
Ignition Voltage Hi <= 31.99023 Volts
Engine Speed >= 400 RPM
Engine Speed <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
Engine Torque Lo >= 50 N*m
Engine Torque Hi <= 8191.875 N*m
Transmission Fluid
>= -6.65625 ºC
Temperature Lo
Transmission Fluid
<= 130 ºC
Temperature Hi
TCC Command
Lock ON or ON = TRUE Boolean
mode
PTO Not Active = TRUE Boolean
Engine Torque Signal
= TRUE Boolean
Valid
Throttle Position
= TRUE Boolean
Signal Valid
Dynamic Mode = FALSE Boolean
Test
Failed
This Key
P0741 Status is
On or
Fault
Active
Torque One
Converter P0742 TCC System Stuck ON TCC Slip Speed >= -50 RPM Trip
Clutch (TCC)
TCC Slip Speed <= 30 13 RPM
Fail Time
>= 1
(Sec)
If Above
Conditions Have
been Met, and Fail Fail
>= 8
Timer Expired, Counter
Increment Fail
Counter
Transmission Sump
>= - 7 15 ºC
Temperature
Throttle Position Hyst
>= 10.00061 Pct
High
Throttle Position Hyst
<= 2.999878 Pct
Low
AND
Max Vehicle Speed to
<= 8 KPH
Meet Throttle Enable
Two
Mode 2 Shift Solenoid Valve A Commaned Gear
P0751 >= 400 RPM Trips
Multiplex Valve Stuck Off Slip
1st
Commanded Gear = rpm
Lock
Gear Ratio <= 1.5183 >= 0.3 Fail Tmr
Neutral
0
Timer (Sec)
Fail Timer
>= 0.3
(Sec)
>= 8 Counts
Ignition Voltage Lo >= 9 Volts
Ignition Voltage Hi <= 31.99023 Volts
MH8/T76 SECTION Page 36 of 276 2 OF 3 SECTIONS
MH8/T76 SECTION
12 OBDG04 Transmission Diagnostics 2 OF 3 SECTIONS
Component/ Fault Monitor Strategy Malfunction Threshold Secondary Enable Time Mil
System Code Description Criteria Value Malfunction Conditions Required Illum.
Engine Speed Lo >= 400 RPM
Engine Speed Hi <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
Transmission Fluid
>= -6.65625 ºC
Temperature
Range
Shift
Range Shift State = ENUM
Complete
d
High-Side Driver is
= TRUE Boolean
Enabled
Input Speed Sensor
= FALSE Boolean
fault
Output Speed Sensor
= FALSE Boolean
fault
Default Gear Option
= TRUE
is not present
One
Mode 2 Shift Solenoid Valve A
P0752 Gear Box Slip >= 400 RPM Trip
Multiplex Valve Stuck On
Commanded Gear
has Achieved 1st
Locked OR 1st
Free-Wheel OR = TRUE Boolean
2nd with Mode 2
Sol. Commanded
On
C456/CBR1 Pressur
= Boolean
Pressure Switch ized
C456/CBR1
Pressure Switch = FALSE Boolean
Fault
If the above
parameters are
true
Please
Refer
to
Table
Neutral
>= 16 in
Timer (Sec)
Suppor
ting
Docum
ents
Command 4th
Gear once Output <= 1000 RPM
Shaft Speed
Fail One
Pressure Control (PC)
Variable Bleed Case Case: Steady State Trip
P0776 Solenoid B Stuck Off
Solenoid (VBS) 1 3rd Gear
[C35R]
Please
Refer
to
Table 5
Neutral
>= 16 in
Timer (Sec)
Suppor
ting
Docum
ents
Command 4th
Gear once Output <= 1000 RPM
Shaft Speed
or
and C35R Fail 3-5R Clutch
>= 14
counter Fail Counts
Fail
Case: Steady State
Case
5th Gear
2
Please
Refer
to
Table 5
Neutral
Gearbox Slip >= 400 Rpm >= in
Timer (Sec)
Suppor
ting
Docum
ents
Intrusive Test:
Command 6th
Gear
Please
refer to
Table 3
If attained
in Shift Time
Gear=6th gear >=
supporti (Sec)
Time
ng
docume
nts
It the above
condiations are 5th Gear
>= 3
true, Increment 5th Fail Counts
gear fail counter
or
and C35R Fail 3-5R Clutch
>= 14
counter Fail Counts
PRNDL State
= FALSE Boolean
defaulted
inhibit RVT = FALSE Boolean
IMS fault pending
= FALSE Boolean
indication
TPS validity flag = TRUE Boolean
Hydraulic System
= TRUE Boolean
Pressurized
Minimum output
>= 0 RPM
speed for RVT
A OR B
Fail One
Pressure Control (PC)
Variable Bleed Case Case: Steady State Trip
P0777 Solinoid B Stuck On
Solenoid (VBS) 1 1st
[C35R] (Steady State)
Table
Based
Time
Please
Refer to
If the Above is Enable Time
>= Table 4
True for Time (Sec)
in
supporti
ng
docume
nts
Intrusive test:
(CBR1 clutch
exhausted)
Gear Ratio <= 2.0073
Table
Based
value
Please
Refer to
Max Delta Output 3D
>= rpm/sec
Speed Hysteresis Table 1
in
supporti
ng
docume
nts
Table
Based
value
Please
Refer to
Min Delta Output 3D
>= rpm/sec
Speed Hysteresis Table 2
in
supporti
ng
docume
nts
Table
Based
Time
Please
Refer to
If the Above is
>= Table Sec
True for Time
17 in
supporti
ng
docume
nts
Intrusive test:
(CB26 clutch
exhausted)
Gear Ratio <= 2.0073
Table
Based
value
Please
Refer to
Max Delta Output 3D
>= rpm/sec
Speed Hysteresis Table 1
in
supporti
ng
docume
nts
Table
Based
value
Please
Refer to
Min Delta Output 3D
>= rpm/sec
Speed Hysteresis Table 2
in
supporti
ng
docume
nts
Table
Based
Time
Please
Refer to
If the Above is
>= Table Sec
True for Time
17 in
supporti
ng
docume
nts
Intrusive test:
(C1234 clutch
exhausted)
Table
Based
value
Please
Refer to
Max Delta Output 3D
>= rpm/sec
Speed Hysteresis Table 1
in
supporti
ng
docume
nts
Table
Based
value
Please
Refer to
Min Delta Output 3D
>= rpm/sec
Speed Hysteresis Table 2
in
supporti
ng
docume
nts
Table
Based
Time
Please
Refer to
If the Above is
>= Table Sec
True for Time
17 in
supporti
ng
docume
nts
Intrusive test:
(CB26 clutch
exhausted)
Fail Timer
Gear Ratio <= 1.0699 >= 1.1
(Sec)
Gear Ratio >= 0.9301 >= 3 counts
If the above
parameters are
true
Fail Timer
>= 1.1
(Sec)
Fail Count
>= 3
in 6th Gear
or
if Attained Gear=1st
FW Accelerator >= 10.00061 Pct
Pedal enable
if Attained Gear=1st
FW Engine Torque >= 45 Nm
Enable
if Attained Gear=1st
FW Engine Torque <= 8191.875 Nm
Enable
Transmission Fluid
>= -6.65625 ºC
Temperature
Input Speed Sensor
= FALSE Boolean
fault
Output Speed Sensor
= FALSE Boolean
fault
Maximu
Primary Oncoming
m
Clutch Pressure =
pressuri
Command Status
zed
Clutch
Primary Offgoing
exhaust
Clutch Pressure =
comma
Command Status
nd
Initial
Range Shift Status Clutch
Control
Total
Fail
Time =
(Fail 1
+ Fail
2) See
Enable
Timers
If Attained Gear
for Fail
Slip is Less than
Timer
Above Cal >= sec
1, and
Increment Fail
Refere
Timers
nce
Suppor
ting
Table
15 for
Fail
Timer
2
If fail timer is
greater than
threshold
increment
corresponding
gear fail counter
and total fail
counter
3rd gear fail 3rd gear fail
>= 3
counter counts
OR
5th gear fail 5th gear fail
>= 3
counter counts
OR
total fail
Total fail counter >= 5
counts
Test
Failed
P077C Status is This
=
not Key On
or Fault
Active
If the above
conditons have
been met,
increment the
P077C Fail
Counter
DTC P077C Sets
when the Fail >= 75 Counts
Counter
P077C Enable
= 1 Boolean
Calibration
Ignition Voltage Lo >= 9 Volts
Ignition Voltage Hi <= 31.99023 Volts
One
Transmission Trip
Output Speed Sensor TOSS Analog
Output Speed P077D >= 4.75 Volts >= 0.05 sec
Circuit High Signal Voltage
Sensor (TOSS)
Test
Failed
P077D Status is This
=
not Key On
or Fault
Active
Fail One
Pressure Control (PC)
Variable Bleed Case Case: Steady State Trip
P0796 Solenoid C Stuck Off
Solenoid (VBS) 1 4th Gear
[C456] (Steady State)
Please
See
Table 5
Neutral
Gear slip >= 400 RPM >= For
Timer (Sec)
Neutral
Time
Cal
Intrusive test:
commanded 5th
gear
Please
refer to
Table 3
If attained Gear in Shift Time
>=
5th for time Support (Sec)
ing
Docum
ents
Please
See
Table 5
Neutral
Gear slip >= 400 RPM >= For
Timer (Sec)
Neutral
Time
Cal
Intrusive test:
commanded 6th
gear
Please
Refer to
Table 3
If attained Gear in Shift Time
>=
6th for time Support (Sec)
ing
Docum
ents
if the above
conditions have
been met
Please
See
Table 5
Neutral
Gear slip >= 400 RPM >= For
Timer (Sec)
Neutral
Time
Cal
Intrusive test:
commanded 5th
gear
Please
refer to
Table 3
If attained Gear in Shift Time
>=
5th for time Support (Sec)
ing
Docum
ents
if the above
conditions have
been met
OR
and C456 Fail C456 Fail
>= 14
Counter Counts
PRNDL State
= FALSE Boolean
defaulted
inhibit RVT = FALSE Boolean
IMS fault pending
= FALSE Boolean
indication
TPS validity flag = TRUE Boolean
Hydraulic System
= TRUE Boolean
Pressurized
Table
Based
Time
Please
Refer to
If the Above is Enable Time
>= Table 4
True for Time (Sec)
in
supporti
ng
docume
nts
Intrusive test:
(CBR1 clutch
exhausted)
Gear Ratio <= 1.5291
Table
Based
value
Please
Refer to
Max Delta Output 3D
>= rpm/sec
Speed Hysteresis Table 1
in
supporti
ng
docume
nts
Table
Based
value
Please
Refer to
Min Delta Output 3D
>= rpm/sec
Speed Hysteresis Table 2
in
supporti
ng
docume
nts
Table
Based
Time
Please
Refer to
If the Above is
>= Table Sec
True for Time
17 in
supporti
ng
docume
nts
Intrusive test:
(CB26 clutch
exhausted)
Fail
Case Steady State
Case
3rd
3
Table
Based
value
Please
Refer to
Max Delta Output 3D
>= rpm/sec
Speed Hysteresis Table 1
in
supporti
ng
docume
nts
Table
Based
value
Please
Refer to
Min Delta Output 3D
>= rpm/sec
Speed Hysteresis Table 2
in
supporti
ng
docume
nts
Table
Based
Time
Please
Refer to
If the Above is
>= Table Sec
True for Time
17 in
supporti
ng
docume
nts
Intrusive test:
(C35R clutch
exhausted)
Gear Ratio <= 1.5291
if Attained Gear=1st
FW Accelerator >= 10.00061 Pct
Pedal enable
if Attained Gear=1st
FW Engine Torque >= 45 Nm
Enable
if Attained Gear=1st
FW Engine Torque <= 8191.875 Nm
Enable
Transmission Fluid
>= -6.65625 ºC
Temperature
Input Speed Sensor
= FALSE Boolean
fault
Output Speed Sensor
= FALSE Boolean
fault
Maximu
Primary Oncoming
m
Clutch Pressure =
pressuri
Command Status
zed
Clutch
Primary Offgoing
exhaust
Clutch Pressure =
comma
Command Status
nd
Initial
Range Shift Status Clutch
Control
Total
Fail
Time =
(Fail 1
+ Fail
2) See
Enable
Timers
If Attained Gear
for Fail
Slip is Less than
Timer
Above Cal >= sec
1, and
Increment Fail
Refere
Timers
nce
Suppor
ting
Table
15 for
Fail
Timer
2
If fail timer is
greater than
threshold
increment
corresponding
gear fail counter
and total fail
counter
Fail
4th gear fail Counter
>= 3
counter From 4th
Gear
OR
Fail
5th gear fail Counter
>= 3
counter From 5th
Gear
OR
One
Transmission
Input/Turbine Speed TISS Analog Trip
Input Speed P07BF <= 0.25 Volts >= 0.05 sec
Sensor A Circuit Low Signal Voltage
Sensor (TISS)
Test
Failed
P07BF Status is This
=
not Key On
or Fault
Active
If the above
conditons have
been met,
increment the
P07BF Fail
Counter
DTC P07BF Sets
when the Fail >= 75 Counts
Counter
P07BF Enable
= 1 Boolean
Calibration
Ignition Voltage Lo >= 9 Volts
Ignition Voltage Hi <= 31.99023 Volts
One
Transmission
Input/Turbine Speed TISS Analog Trip
Input Speed P07C0 >= 4.75 Volts >= 0.05 sec
Sensor A Circuit High Signal Voltage
Sensor (TISS)
Test
Failed
P07C0 Status is This
=
not Key On
or Fault
Active
If the above
conditons have
been met,
increment the
P07C0 Fail
Counter
DTC P07C0 Sets
when the Fail >= 75 Counts
Counter
P07C0 Enable
= 1 Boolean
Calibration
Ignition Voltage Lo >= 9 Volts
Ignition Voltage Hi <= 31.99023 Volts
Fail Special
Case Tap Up Switch No MIL
Tap Up Tap
1 Stuck in the Up
Down Switch P0815 Upshift Switch Circuit = 0 Boolean
Position in Range
(TUTD)
1 Enabled
Tap Up Switch
Stuck in the Up
= 0 Boolean
Position in Range
2 Enabled
Tap Up Switch
Stuck in the Up
= 0 Boolean
Position in Range
3 Enabled
Tap Up Switch
Stuck in the Up
= 0 Boolean
Position in Range
4 Enabled
Tap Up Switch
Stuck in the Up
= 0 Boolean
Position in Range
5 Enabled
Tap Up Switch
Stuck in the Up
= 0 Boolean
Position in Range
6 Enabled
Tap Up Switch
Stuck in the Up
= 1 Boolean
Position in Neutral
Enabled
Tap Up Switch
Stuck in the Up
= 1 Boolean
Position in Park
Enabled
Tap Up Switch
Stuck in the Up
= 0 Boolean
Position in Reverse
Enabled
Fail Time
Tap Up Switch ON = TRUE Boolean >= 1
(Sec)
Tap Up Switch
Stuck in the Up
= 1 Boolean
Position in Range
2 Enabled
Tap Up Switch
Stuck in the Up
= 1 Boolean
Position in Range
3 Enabled
Tap Up Switch
Stuck in the Up
= 1 Boolean
Position in Range
4 Enabled
Tap Up Switch
Stuck in the Up
= 1 Boolean
Position in Range
5 Enabled
Tap Up Switch
Stuck in the Up
= 1 Boolean
Position in Range
6 Enabled
Tap Up Switch
Stuck in the Up
= 0 Boolean
Position in Neutral
Enabled
Tap Up Switch
Stuck in the Up
= 0 Boolean
Position in Park
Enabled
Tap Up Switch
Stuck in the Up
= 0 Boolean
Position in Reverse
Enabled
NOTE: Both
Failcase1 and Fail Time
>= 600
Failcase 2 Must Be (Sec)
Met
Enable
Time Since Last
>= 1 Time
Range Change
(Sec)
Ignition Voltage Lo >= 9 Volts
Ignition Voltage Hi <= 31.99023 Volts
Engine Speed Lo >= 400 RPM
Engine Speed Hi <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
Test
Failed
This Key
P0815 Status is
On or
Fault
Active
ECM: None
Fail
Case Tap Down Switch
2 Stuck in the Down
= 1 Boolean
Position in Range
1 Enabled
Enable
Time Since Last
>= 1 Time
Range Change
(Sec)
Ignition Voltage Lo >= 9 Volts
Ignition Voltage Hi <= 31.99023 Volts
Engine Speed Lo >= 400 RPM
Engine Speed Hi <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
Test
Failed
This Key
P0816 Status is
On or
Fault
Active
ECM: None
Two
Pressure Control (PC) The HWIO reports Trips
Variable Bleed Solenoid A Control an invalid voltage Fail Time
P0961 = TRUE Boolean >= 4.4
Solenoid (VBS) Circuit Rationality Test (out of range) error (Sec)
(Line Pressure VBS) flag
out Sample
5
of Time (Sec)
Ignition Voltage >= 9 Volts
Ignition Voltage <= 31.99023 Volts
Engine Speed >= 400 RPM
Engine Speed <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
One
Pressure Control (PC) The HWIO reports Trip
Variable Bleed Solenoid A Control a low voltage Fail Time
P0962 = TRUE Boolean >= 1.5
Solenoid (VBS) Circuit Low Voltage (ground short) (Sec)
(Line Pressure VBS) error flag
out Sample
1.875
of Time (Sec)
Ignition Voltage >= 9 Volts
Ignition Voltage <= 31.99023 Volts
Engine Speed >= 400 RPM
Engine Speed <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
Two
Trips
out Sample
5
of Time (Sec)
Ignition Voltage >= 9 Volts
Ignition Voltage <= 31.99023 Volts
Engine Speed >= 400 RPM
Engine Speed <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
One
Pressure Control (PC) The HWIO reports Trip
Variable Bleed Solenoid B Control a low voltage Fail Time
P0966 = TRUE Boolean >= 0.3
Solenoid (VBS) Circuit Low Voltage (ground short) (Sec)
(C35R VBS) error flag
out Sample
0.375
of Time (Sec)
Ignition Voltage >= 9 Volts
Ignition Voltage <= 31.99023 Volts
Engine Speed >= 400 RPM
Engine Speed <= 7500 RPM
One
Pressure Control (PC) The HWIO reports Trip
Variable Bleed Solenoid B Control a high voltage Fail Time
P0967 = TRUE Boolean >= 0.3
Solenoid (VBS) Circuit High Voltage (open or power (Sec)
(C35R VBS) short) error flag
out Sample
0.375
of Time (Sec)
Ignition Voltage >= 9 Volts
Ignition Voltage <= 31.99023 Volts
Engine Speed >= 400 RPM
Engine Speed <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
Test
Failed
This Key
P0967 Status is not =
On or
Fault
Active
out Sample
0.375
of Time (Sec)
Test
Failed
This Key
P0970 Status is not =
On or
Fault
Active
Ignition Voltage >= 9 Volts
Ignition Voltage <= 31.99023 Volts
Engine Speed >= 400 RPM
Engine Speed <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
One
Pressure Control (PC) The HWIO reports Trip
Variable Bleed Solenoid C Control a high voltage Fail Time
P0971 = TRUE Boolean >= 0.3
Solenoid (VBS) Circuit High Voltage (open or power (Sec)
(C456/CBR1 VBS) short) error flag
out Sample
0.375
of Time (Sec)
Test
Failed
This Key
P0971 Status is not =
On or
Fault
Active
Ignition Voltage >= 9 Volts
Ignition Voltage <= 31.99023 Volts
MH8/T76 SECTION Page 81 of 276 2 OF 3 SECTIONS
MH8/T76 SECTION
12 OBDG04 Transmission Diagnostics 2 OF 3 SECTIONS
Component/ Fault Monitor Strategy Malfunction Threshold Secondary Enable Time Mil
System Code Description Criteria Value Malfunction Conditions Required Illum.
Engine Speed >= 400 RPM
Engine Speed <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
out Sample
1.5
of Time (Sec)
Test
Failed
This Key
P0973 Status is not =
On or
Fault
Active
Ignition Voltage >= 9 Volts
Ignition Voltage <= 31.99023 Volts
Engine Speed >= 400 RPM
Engine Speed <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
Two
The HWIO reports Trips
Shift Solenoid A
a high voltage Fail Time
Shift Solinoid P0974 Control Circuit High = TRUE Boolean >= 1.2
(open or power (Sec)
(Mode 2 Solenoid)
short) error flag
out Sample
1.5
of Time (Sec)
Test
Failed
This Key
P0974 Status is not =
On or
Fault
Active
Ignition Voltage >= 9 Volts
Ignition Voltage <= 31.99023 Volts
Engine Speed >= 400 RPM
Engine Speed <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
Fail One
Case Transiti Trip
Internal Mode Internal Mode Switch - 1 on 1 (bit
P182E Current range = Range
Switch (IMS) Invalid Range state
1110)
CeTRG
R_e_P
Previous range Range
RNDL_
Drive6
CeTRG
R_e_P
Previous range Range
RNDL_
Drive5
Range
Shift
Range Shift State = ENUM
Comple
ted
MH8/T76 SECTION Page 83 of 276 2 OF 3 SECTIONS
MH8/T76 SECTION
12 OBDG04 Transmission Diagnostics 2 OF 3 SECTIONS
Component/ Fault Monitor Strategy Malfunction Threshold Secondary Enable Time Mil
System Code Description Criteria Value Malfunction Conditions Required Illum.
Absolute Attained
<= 50 rpm
Gear Slip
If the above
conditions are met Fail
>= 1
then Increment Fail Seconds
Timer
The following
PRNDL sequence
events occur in this
exact order:
Drive 6
(bit
PRNDL state = Range
state
0110)
PRNDL state =
>= 1 Sec
Drive 6 for
Transiti
on 8 (bit
PRNDL state = Range
state
0111)
Drive 6
(bit
PRNDL state = Range
state
0110)
Transiti
on 1 (bit
PRNDL state = Range
state
1110)
Above sequencing
<= 1 Sec
occurs in
If all conditions
above are met
Increment delay
Timer
If the below two
conditions are met Fail
>= 3
Increment Fail Seconds
Timer
CeTRGR
Engine Torque >= -8192 Nm Previous range _e_PRND
L_Drive2
IMS is 7 position
Engine Torque <= 8191.8 Nm = 0 Boolean
configuration
If the "IMS 7 Position
If the above config" = 1 then the
conditions are met "previous range" >= 0.225 Seconds
then, Increment criteria above must
Fail Timer also be satsified
when the "current
If Fail Timer has
Expired then
>= 15 Fail Counts
Increment Fail
Counter
Fail
Case Disable Fail Case 4 if
4 Transiti last positive range
Current range = on 8 (bit Range was Drive 6 and
state current range is
0111) transition 8
Steady State
>= 30 Nm
Engine Torque
Steady State
<= 8191.8 Nm
Engine Torque
If the above
conditions are met
>= 0.225 Seconds
then Increment Fail
Timer
The following
PRNDL sequence
events occur in this
exact order:
Revers
e (bit
PRNDL State = Range
state
1100)
Transiti
on 11
PRNDL State = (bit Range
state
0100)
Neutral
(bit
PRNDL State = Range
state
0101)
Transiti
on 11
PRNDL State = (bit Range
state
0100)
Above sequencing
<= 1 Sec
occurs in
Then delay timer
increments
Delay timer >= 5 sec
Range
Shift
Range Shift State =
Comple
te
Absolute Attained
<= 50 rpm
Gear Slip
If the above
conditions are met
>= 20 Seconds
Increment Fail
Timer
Fail
Case Illegal
6 (bit A Open Circuit
state Definition (flag set
Current range =
0000 or false if the following
1000 or conditions are met):
0001)
Transition
11 (bit
and Current Range
state
0100)
A Open Circuit
= FALSE Boolean or
(See Definition)
Neutral
Last positive state (bit state
0101)
or
Transition
Previous transition
8 (bit
state
state
0111)
Fail case 5 delay
= 0 sec
timer
If the above
Condtions are met
>= 6.25 Seconds
then, Increment
Fail timer
Fail
Case PRNDL
7 Current PRNDL circuit
= Range
State ABCP =
1101
and
PRNDL
Previous PRNDL circuit
= Range
state ABCP
=1111
If the above
Condtions are met
>= 6.25 Seconds
then, Increment
Fail timer
One
Internal Mode Switch Trip
Internal Mode Does Not Indicate Park or
P1915 PRNDL State is Enumeration
Switch (IMS) Park/Neutral (P/N) Neutral
During Start
The following
events must occur
Sequentially
Fail One
Pressure Control (PC)
Variable Bleed Case Case: Steady State Trip
P2714 Solenoid D Stuck Off
Solenoid (VBS) 1 2nd Gear
[CB26]
Please
See
Table 5
Neutral
Gear slip >= 400 RPM >= For
Timer (Sec)
Neutral
Time
Cal
Please
See
Table 5
Neutral
Gear slip >= 400 RPM >= For
Timer (Sec)
Neutral
Time
Cal
Intrusive test:
commanded 5th
gear
Maximu
Primary Oncoming
m
Clutch Pressure =
pressuri
Command Status
zed
Clutch
Primary Offgoing
exhaust
Clutch Pressure =
comma
Command Status
nd
Initial
Range Shift Status Clutch
Control
If above coditons
are true, increment
appropriate Fail 1
Timers Below:
fail timer 1
Fail Time
(2-1 shifting with >= 0.7002
(Sec)
throttle)
fail timer 1
Fail Time
(2-1 shifting >= 0.9004
(Sec)
without throttle)
fail timer 1
Fail Time
(2-3 shifting with >= 0.7002
(Sec)
throttle)
fail timer 1
Fail Time
(2-3 shifting >= 0.9004
(Sec)
without throttle)
fail timer 1
Fail Time
(2-4 shifting with >= 0.7002
(Sec)
throttle)
fail timer 1
Fail Time
(2-4 shifting >= 0.9004
(Sec)
without throttle)
fail timer 1
Fail Time
(6-4 shifting with >= 0.7002
(Sec)
throttle)
fail timer 1
Fail Time
(6-4 shifting >= 0.9004
(Sec)
without throttle)
Total
Fail
Time =
(Fail 1
+ Fail
2) See
Enable
Timers
If Attained Gear
for Fail
Slip is Less than
Timer
Above Cal >= sec
1, and
Increment Fail
Refere
Timers
nce
Suppor
ting
Table
15 for
Fail
Timer
2
If fail timer is
greater than
threshold
increment
corresponding
gear fail counter
and total fail
counter
Fail
2nd gear fail Counter
>= 3
counter From 2nd
Gear
OR
MH8/T76 SECTION Page 96 of 276 2 OF 3 SECTIONS
MH8/T76 SECTION
12 OBDG04 Transmission Diagnostics 2 OF 3 SECTIONS
Component/ Fault Monitor Strategy Malfunction Threshold Secondary Enable Time Mil
System Code Description Criteria Value Malfunction Conditions Required Illum.
Fail
6th gear fail Counter
>= 3
counter From 6th
Gear
OR
Total Fail
total fail counter >= 5
Counter
TUT Enable
>= -6.65625 ºC
temperature
Input Speed Sensor
= FALSE Boolean
fault
Output Speed Sensor
= FALSE Boolean
fault
Command / Attained
1st Boolean
Gear
High Side Driver ON = TRUE Boolean
output speed limit for
>= 200 RPM
TUT
input speed limit for
>= 200 RPM
TUT
PRNDL state
= FALSE Boolean
defaulted
IMS Fault Pending = FALSE Boolean
Service Fast Learn
= FALSE Boolean
Mode
HSD Enabled = TRUE Boolean
Table
Based
Time
Please
Refer to
If the Above is Enable Time
>= Table 4
True for Time (Sec)
in
supporti
ng
docume
nts
Intrusive test:
(CBR1 clutch
exhausted)
Gear Ratio <= 3.1127
Table
Based
value
Please
Refer to
Max Delta Output 3D
>= rpm/sec
Speed Hysteresis Table 1
in
supporti
ng
docume
nts
Table
Based
value
Please
Refer to
Min Delta Output 3D
>= rpm/sec
Speed Hysteresis Table 2
in
supporti
ng
docume
nts
Table
Based
Time
Please
Refer to
If the Above is
>= Table Sec
True for Time
17 in
supporti
ng
docume
nts
Intrusive test:
(C35R clutch
exhausted)
Table
Based
value
Please
Refer to
Max Delta Output 3D
>= rpm/sec
Speed Hysteresis Table 1
in
supporti
ng
docume
nts
Table
Based
value
Please
Refer to
Min Delta Output 3D
>= rpm/sec
Speed Hysteresis Table 2
in
supporti
ng
docume
nts
Table
Based
Time
Please
Refer to
If the Above is
>= Table Sec
True for Time
17 in
supporti
ng
docume
nts
Intrusive test:
(C1234 clutch
exhausted)
Gear Ratio <= 0.7982
Table
Based
value
Please
Refer to
Max Delta Output 3D
>= rpm/sec
Speed Hysteresis Table 1
in
supporti
ng
docume
nts
Table
Based
value
Please
Refer to
Min Delta Output 3D
>= rpm/sec
Speed Hysteresis Table 2
in
supporti
ng
docume
nts
Table
Based
Time
Please
Refer to
If the Above is
>= Table Sec
True for Time
17 in
supporti
ng
docume
nts
Intrusive test:
(C35R clutch
exhausted)
Gear Ratio <= 0.7982
if Attained Gear=1st
FW Accelerator >= 10.00061 Pct
Pedal enable
if Attained Gear=1st
FW Engine Torque >= 45 Nm
Enable
if Attained Gear=1st
FW Engine Torque <= 8191.875 Nm
Enable
Transmission Fluid
>= -6.65625 ºC
Temperature
Input Speed Sensor
= FALSE Boolean
fault
Output Speed Sensor
= FALSE Boolean
fault
Default Gear Option
= TRUE
is not present
out Sample
0.375
of Time (Sec)
Test
Failed
This Key
P2770 Status is not =
On or
Fault
Active
Ignition Voltage >= 9 Volts
Ignition Voltage <= 31.99023 Volts
Engine Speed >= 400 RPM
Engine Speed <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
out Sample
0.375
of Time (Sec)
Test
Failed
This Key
P2721 Status is not =
On or
Fault
Active
Ignition Voltage >= 9 Volts
Ignition Voltage <= 31.99023 Volts
Engine Speed >= 400 RPM
Engine Speed <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
Fail One
Variable Bleed Pressure Control (PC) Case Case: Steady State Trip
P2723
Solenoid (VBS) Solenoid E Stuck Off 1 1st Gear
Please
See
Table 5
Neutral
Gear slip >= 400 RPM >= For
Timer (Sec)
Neutral
Time
Cal
Intrusive test:
commanded 2nd
gear
Please
refer to
Table 3
If attained Gear in Shift Time
>=
2nd for Time Support (Sec)
ing
Docum
ents
If Above
Conditions have
1st Gear
been met, >= 2
Fail Count
Increment 1st gear
fail counter
or
C1234
and C1234 fail
>= 14 Clutch Fail
counter
Count
Fail
Case: Steady State
Case
2nd Gear
2
Please
See
Table 5
Neutral
Gear slip >= 400 RPM >= For
Timer (Sec)
Neutral
Time
Cal
Intrusive test:
commanded 3rd
gear
Please
refer to
Table 3
If attained Gear in Shift Time
>=
3rd for Time Support (Sec)
ing
Docum
ents
Please
See
Table 5
Neutral
Gear slip >= 400 RPM >= For
Timer (Sec)
Neutral
Time
Cal
Intrusive test:
commanded 4th
gear
Please
refer to
Table 3
If attained Gear in Shift Time
>=
4th for time Support (Sec)
ing
Docum
ents
If Above
Conditions have
3rd Gear
been met, >= 2
Fail Count
Increment 3rd gear
fail counter
or
C1234
and C1234 fail
>= 14 Clutch Fail
counter
Count
Please
See
Table 5
Neutral
Gear slip >= 400 RPM >= For
Timer (Sec)
Neutral
Time
Cal
Intrusive test:
commanded 5th
gear
Please
refer to
Table 3
If attained Gear = in Shift Time
>=
5th For Time Support (Sec)
ing
Docum
ents
If Above
Conditions have
4th Gear
been met, >= 3
Fail Count
Increment 4th gear
fail counter
or
C1234
and C1234 fail
>= 14 Clutch Fail
counter
Count
PRNDL State
= FALSE Boolean
defaulted
inhibit RVT = FALSE Boolean
IMS fault pending
= FALSE Boolean
indication
TPS validity flag = TRUE Boolean
Hydraulic System
= TRUE Boolean
Pressurized
Minimum output
>= 0 RPM
speed for RVT
A OR B
MH8/T76 SECTION Page 109 of 276 2 OF 3 SECTIONS
MH8/T76 SECTION
12 OBDG04 Transmission Diagnostics 2 OF 3 SECTIONS
Component/ Fault Monitor Strategy Malfunction Threshold Secondary Enable Time Mil
System Code Description Criteria Value Malfunction Conditions Required Illum.
(A) Output speed
>= 100 RPM
enable
(B) Accelerator Pedal
>= 0.500488 Pct
enable
Common Enable
Criteria
Ignition Voltage Lo >= 9 Volts
Ignition Voltage Hi <= 31.99023 Volts
Engine Speed Lo >= 400 RPM
Engine Speed Hi <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
Throttle Position
= TRUE Boolean
Signal valid
HSD Enabled = TRUE Boolean
Transmission Fluid
>= -6.65625 ºC
Temperature
Input Speed Sensor
= FALSE Boolean
fault
Output Speed Sensor
= FALSE Boolean
fault
Default Gear Option
= TRUE
is not present
Maximu
Primary Oncoming
m
Clutch Pressure =
pressuri
Command Status
zed
Clutch
Primary Offgoing
exhaust
Clutch Pressure =
comma
Command Status
nd
Initial
Range Shift Status Clutch
Control
If the above
conditions are true
increment
appropriate Fail 1
Timers Below:
fail timer 1
(2-6 shifting with >= 0.7002 sec
throttle)
fail timer 1
(2-6 shifting >= 0.9004 sec
without throttle)
fail timer 1
(3-5 shifting with >= 0.7002 sec
throttle)
fail timer 1
(3-5 shifting >= 0.9004 sec
without throttle)
Total
Fail
Time =
(Fail 1
+ Fail
2) See
Enable
Timers
If Attained Gear
for Fail
Slip is Less than
Timer
Above Cal >= sec
1, and
Increment Fail
Refere
Timers
nce
Suppor
ting
Table
15 for
Fail
Timer
2
If fail timer is
greater than
threshold
increment
corresponding
gear fail counter
and total fail
counter
MH8/T76 SECTION Page 112 of 276 2 OF 3 SECTIONS
MH8/T76 SECTION
12 OBDG04 Transmission Diagnostics 2 OF 3 SECTIONS
Component/ Fault Monitor Strategy Malfunction Threshold Secondary Enable Time Mil
System Code Description Criteria Value Malfunction Conditions Required Illum.
Fail
2nd gear fail Counter
>= 3
counter From 2nd
Gear
Fail
3rd gear fail Counter
>= 3
counter From 3rd
Gear
Fail
4th gear fail Counter
>= 3
counter From 4th
Gear
Total Fail
total fail counter >= 5
Counter
TUT Enable
>= -6.65625 ºC
temperature
Input Speed Sensor
= FALSE Boolean
fault
Output Speed Sensor
= FALSE Boolean
fault
Command / Attained
1st Boolean
Gear
High Side Driver ON = TRUE Boolean
output speed limit for
>= 200 RPM
TUT
input speed limit for
>= 200 RPM
TUT
PRNDL state
= FALSE Boolean
defaulted
IMS Fault Pending = FALSE Boolean
Service Fast Learn
= FALSE Boolean
Mode
HSD Enabled = TRUE Boolean
Fail One
Pressure Control (PC)
Variable Bleed Case Trip
P2724 Solenoid E Stuck On Case: 5th Gear
Solenoid (VBS) 1
(Steady State)
Table
Based
value
Please
Refer to
Max Delta Output 3D
>= rpm/sec
Speed Hysteresis Table 1
in
supporti
ng
docume
nts
Table
Based
value
Please
Refer to
Min Delta Output 3D
>= rpm/sec
Speed Hysteresis Table 2
in
supporti
ng
docume
nts
Table
Based
Time
Please
Refer to
If the Above is
>= Table Sec
True for Time
17 in
supporti
ng
docume
nts
Intrusive test:
(C35R clutch
exhausted)
Gear Ratio <= 1.5291
Table
Based
value
Please
Refer to
Max Delta Output 3D
>= rpm/sec
Speed Hysteresis Table 1
in
supporti
ng
docume
nts
Table
Based
value
Please
Refer to
Min Delta Output 3D
>= rpm/sec
Speed Hysteresis Table 2
in
supporti
ng
docume
nts
Table
Based
Time
Please
Refer to
If the Above is
>= Table Sec
True for Time
17 in
supporti
ng
docume
nts
Intrusive test:
(CB26 clutch
exhausted)
Gear Ratio <= 1.5291
if Attained Gear=1st
FW Accelerator >= 10.00061 Pct
Pedal enable
if Attained Gear=1st
FW Engine Torque >= 45 Nm
Enable
if Attained Gear=1st
FW Engine Torque <= 8191.875 Nm
Enable
Transmission Fluid
>= -6.65625 ºC
Temperature
Input Speed Sensor
= FALSE Boolean
fault
Output Speed Sensor
= FALSE Boolean
fault
Default Gear Option
= TRUE
is not present
out Sample
0.375
of Time (Sec)
Test
Failed
This Key
P2729 Status is not =
On or
Fault
Active
Ignition Voltage >= 9 Volt
Ignition Voltage <= 31.99023 Volt
Engine Speed >= 400 RPM
Engine Speed <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
out Sample
0.375
of Time (Sec)
Test
Failed
This Key
P2730 Status is not =
On or
Fault
Active
Ignition Voltage >= 9 Volt
Ignition Voltage <= 31.99023 Volt
Engine Speed >= 400 RPM
Engine Speed <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
out Sample
5
of Time (Sec)
Test
Failed
This Key
P2763 Status is not =
On or
Fault
Active
Ignition Voltage >= 9 Volt
MH8/T76 SECTION Page 120 of 276 2 OF 3 SECTIONS
MH8/T76 SECTION
12 OBDG04 Transmission Diagnostics 2 OF 3 SECTIONS
Component/ Fault Monitor Strategy Malfunction Threshold Secondary Enable Time Mil
System Code Description Criteria Value Malfunction Conditions Required Illum.
Ignition Voltage <= 31.99023 Volt
Engine Speed >= 400 RPM
Engine Speed <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
High Side Driver
= TRUE Boolean
Enabled
One
Controller Area CAN Hardware Fail counts
Trip
Communication U0073 Network Bus Circuitry Detects a = TRUE Boolean >= 62 (§ 10
Communication Error Low Voltage Error seconds)
Sample
Out Counts (§
Delay timer >= 0.1125 sec 70
of 11
seconds)
Stabilization delay >= 3 sec
Ignition Voltage >= 9 Volt
Ignition Voltage <= 31.99023 Volt
Power Mode = Run
Table 1
Axis 0.00 64.00 128.00 192.00 256.00 320.00 384.00 448.00 512.00 N*m
Curve 100.00 120.00 150.00 150.00 150.00 150.00 150.00 150.00 150.00 RPM
Table 2
Axis -6.67 -6.66 40.00 ºC
Curve 409.59 2.00 2.00 Sec
Table 3
Axis -6.67 -6.66 40.00 ºC
Curve 409.59 3.50 3.50 Sec
Table 4
Axis -6.67 -6.66 40.00 ºC
Curve 409.59 2.99 2.00 Sec
Table 5
Axis -6.67 -6.66 40.00 ºC
Curve 409.59 3.00 3.00 Sec
Table 6
Axis -6.67 -6.66 40.00 80.00 120.00 ºC
Curve 409.00 3.60 1.60 1.40 1.40 Sec
Table 7
Axis -6.67 -6.66 40.00 80.00 120.00 ºC
Curve 409.00 3.40 1.40 1.30 1.20 Sec
Table 8
Axis -6.67 -6.66 40.00 80.00 120.00 ºC
Curve 409.00 3.60 1.60 1.50 1.40 Sec
Table 9
Axis -6.67 -6.66 40.00 80.00 120.00 ºC
Curve 409.00 3.30 1.30 1.20 1.10 Sec
Table 10
Axis -40.00 -20.00 0.00 30.00 110.00 ºC
Curve 8.85 3.75 1.31 0.28 0.28 Sec
Table 11
Axis -40.00 -20.00 0.00 30.00 110.00 ºC
Curve 5.00 1.70 0.40 0.25 0.25 Sec
Table 12
Axis -40.00 -20.00 0.00 30.00 110.00 ºC
Curve 8.00 2.20 0.70 0.25 0.25 Sec
Table 13
Axis -40.00 -20.00 0.00 30.00 110.00 ºC
Curve 5.20 1.60 0.50 0.27 0.16 Sec
Table 14
Axis -40.00 -20.00 0.00 30.00 110.00 ºC
Curve 5.00 1.50 0.70 0.25 0.25 Sec
Table 15
Axis -40.00 -30.00 -20.00 -10.00 0.00 10.00 20.00 30.00 40.00 ºC
Curve 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Sec
Table 16
Axis -6.67 -6.66 40.00 ºC
Curve 409.59 2.50 2.50 Sec
Table 17
Axis -6.67 -6.66 40.00 ºC
Curve 0.40 0.35 0.30 Sec
Table 18
Axis -40.10 -40.00 -20.00 0.00 30.00 60.00 100.00 149.00 149.10 ºC
Curve 256.00 50.00 45.00 40.00 34.00 25.00 20.00 20.00 256.00 ºC
Table 19
Axis -40.10 -40.00 -20.00 0.00 30.00 60.00 100.00 149.00 149.10 ºC
Curve 256.00 50.00 45.00 40.00 34.00 25.00 20.00 20.00 256.00 ºC
Table 20
Axis -40.10 -40.00 -20.00 0.00 30.00 60.00 100.00 149.00 149.10 ºC
Curve 256.00 10.00 8.00 8.00 8.00 8.00 8.00 8.00 256.00 ºC
Table 21
Axis -40.00 -20.00 40.00 ºC
Curve 5.00 3.00 1.00 Sec
3D_Table 1
X-Axis Calibration % 0.00 2.00 5.00 25.00 100.00
Y-Axis Calibration ºC -6.67 8191.75 8191.75 8191.75 8191.75 8191.75
Table Calibration RPM/Sec -6.66 8191.75 8191.75 8191.75 8191.75 8191.75
40.00 8191.75 8191.75 8191.75 8191.75 8191.75
3D_Table 2
X-Axis Calibration % 0.00 2.00 5.00 25.00 100.00
Y-Axis Calibration ºC -6.67 8191.75 8191.75 8191.75 8191.75 8191.75
Table Calibration RPM/Sec -6.66 500.00 500.00 300.00 300.00 300.00
40.00 500.00 500.00 300.00 300.00 300.00
Fail Fail
Substrate
Case >= 50 ºC >= 2 Time
Temperature
2 (Sec)
Ignition Voltage >= 18 Volts
Note: either fail
case can set
the DTC
Ignition Voltage Lo >= 8.5996 Volts
Ignition Voltage Hi <= 31.99 Volts
Substrate Temp Lo >= 0 ºC
Substrate Temp Hi <= 170 ºC
Substrate Temp
Between Temp >= 0.25 Sec
Range for Time
Test
Failed
This
P0634 Status is
Key On
or Fault
Active
ECM:
None
Two
Trips
TCM Internal Temp If transmission Refer to
Transmission
(substrate) Sensor oil temp to Table 21 in
Control Module P0667 > ºC
Circuit substrate temp supporting
(TCM)
Range/Performance ǻ documents
If TCM Refer to
substrate temp Table 22 in
> ºC
to power up supporting
temp ǻ documents
Both conditions
above required
>= 3000 3
to increment fail
counter
Note: table
reference temp
Sample
= to the median
Out Counts
temp of trans oil 3750
of (100ms
temp,p substrate
loop)
temp and power
up temp.
Non-continuous
Pass
(intermittent) fail
Counts
conditions will >= 700
(100ms
delay resetting
loop)
fail counter until
Sample
Out Counts
875
of (100ms
loop)
Accelerator Position
= TRUE Boolean
Signal Valid
Ignition Voltage Lo >= 8.5996 Volts
Ignition Voltage Hi <= 31.99 Volts
Engine Speed Lo >= 400 RPM
Engine Speed Hi <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
Brake torque active = FALSE
Below describes the
brake torque entry
criteria
Engine Torque >= 90 N*m
Throttle >= 30 Pct
Transmission Input
<= 200 RPM
Speed
Vehicle Speed <= 8 Kph
Transmission Range Park
Transmission Range
g Neutral
Not
PTO =
Active
Set Brake Torque
Active TRUE if above
>= 7 sec
conditions are met
for:
Below describes the
brake torque exit
criteria
Brake torque entry
= Not Met
criteria
Clutch
Hydraul
Clutch hydraulic
ic Air
pressure
Purge
Event
CeTFT
Clutch used to exit D_e_C
=
brake torque active 3_RatlE
nbl
Test
Failed
This
P0667 Status is
Key On
or Fault
Active
Di bl
Disable MIL nott Ill
Illuminated
i t d TCM
TCM:
Conditions: for DTC's: P0658,
P0668,
P0669,
P06AD,
P06AE,
P0716,
P0712,
P0713,
P0717,
P0722,
P0723,
P0962,
P0963,
P0966,
P0967,
P0970,
P0971,
P215C,
P2720,
ECM:
P0101,
P0102,
P0103,
P0106,
P0107,
P0108,
P0171,
P0172,
P0174,
P0175,
P0201,
P0202,
P0203,
P0204,
P0205,
P0206,
P0207,
P0208,
P0208
P0300,
P0301,
P0302,
P0303,
P0304,
P0305,
P0306,
P0307,
P0308,
P0401,
P042E
Two
TCM internal Trips
Transmission CeTFTI_e_
temperature Type of Sensor
Control Module P0668 = VoltageDir
(substrate) thermistor Used
(TCM) ectProp
failed at a low voltge
If TCM
Substrate
Temperature
<= -249 ºC
Sensor = Direct
Proportional
and Temp
If TCM
Substrate
Temperature
Sensor = >= -249 ºC
Indirect
Proportional
and Temp
Either condition
Fail
above will
>= 60 Timer
satisfy the fail
(Sec)
conditions
Ignition Voltage Lo >= 8.5996 Volts
Ignition Voltage Hi <= 31.99 Volts
Engine Speed Lo >= 400 RPM
E i S
Engine Speed d Hi <
<= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
Test
Failed
This
P0668 Status is
Key On
or Fault
Active
ECM:
None
If TCM
Substrate
Temperature
>= 249 ºC
Sensor = Direct
Proportional
and Temp
If TCM
Substrate
Temperature
Sensor = <= 249 ºC
Indirect
Proportional
and Temp
Either condition
Fail
above will
>= 60 Timer
y the fail
satisfy
(Sec)
conditions
Test
Failed
This
P0669 Status is
Key On
or Fault
Active
ECM:
None
Two
Trips
If TCM power- Refer to
Transmission TCM Power-up Temp
up temp to Table 22 in
Control Module P06AC Sensor Circuit > ºC
substrate temp supporting
(TCM) Range/Performance
ǻ documents
If transmission Refer to
oil temp to Table 20 in
> ºC
power up temp supporting
ǻ documents
Note: table
reference temp
Sample
= to the median
Out Counts
temp of trans oil 3750
of (100ms
temp, substrate
loop)
temp and power
up temp.
Non-continuous
Pass
(intermittent) fail
Counts
conditions will >= 700
(100ms
delay resetting
loop)
fail counter until
Sample
Out Counts
875
of (100ms
loop)
Clutch
Hydraul
Clutch hydraulic
ic Air
pressure
Purge
Event
CeTFT
Clutch used to exit D_e_C
=
brake torque active 3_RatlE
nbl
Test
Failed
This
P06AC Status is
Key On
or Fault
Active
ECM:
P0101,
P0102,
P0103,
P0106,
P0107,
P0108,
P0171,
P0172,
P0174,
P0175,
P0201,
P0202,
P0203,
P0204,
P0205,
Test
Failed
This
P06AD Status is
Key On
or Fault
Active
ECM:
None
Transmission TCM power-up Fail Two
Control Module P06AE thermistor circuit Power Up Temp >= 164 ºC >= 60 Time Trips
(TCM) voltage high (Sec)
Ignition Voltage Lo >= 8.5996 Volts
Ignition Voltage Hi <= 31.99 Volts
Engine Speed Lo >= 400 RPM
Engine Speed Hi <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
Test
Failed
This
P06AE Status is
Keyy On
or Fault
Active
ECM:
None
Two
Trips
Transmission If transmission Refer to
Trans Fluid Temp
Fluid oil temp to Table 21 in
P0711 Sensor Circuit > ºC
Temperature substrate temp supporting
Range/Performance
Sensor (TFT) ǻ documents
If transmission Refer to
oil temp to Table 20 in
> ºC
power up temp supporting
ǻ documents
Note: table
reference temp
Sample
= to the median
Out Counts
temp of trans oil 3750
of (100ms
temp, substrate
loop)
temp and power
up temp.
Non-continuous
Pass
(intermittent) fail
Counts
conditions will >= 700
(100ms
delay resetting
loop)
fail counter until
Sample
Out Counts
875
of (100ms
loop)
Accelerator Position
= TRUE Boolean
Signal Valid
Ignition Voltage Lo >= 8.5996 Volts
Ignition Voltage Hi <= 31.99 Volts
Engine Speed Lo >= 400 RPM
Engine Speed Hi <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
Brake torque active = FALSE
Below describes the
brake torque entry
criteria
Engine Torque >= 90 N*m
Throttle >= 30 Pct
Transmission Input
<= 200 RPM
Speed
Vehicle Speed <= 8 Kph
Transmission Range Park
Transmission Range
g Neutral
Not
PTO =
Active
Set Brake Torque
Active TRUE if above
>= 7 sec
conditions are met
for:
Below describes the
brake torque exit
criteria
Brake torque entry
= Not Met
criteria
Clutch
Hydraul
Clutch hydraulic
ic Air
pressure
Purge
Event
CeTFT
Clutch used to exit D_e_C
=
brake torque active 3_RatlE
nbl
Test
Failed
This
P0711 Status is
Key On
or Fault
Active
Di bl
Disable MIL nott Ill
Illuminated
i t d TCM
TCM:
Conditions: for DTC's: P0658,
P0668,
P0669,
P06AD,
P06AE,
P0716,
P0712,
P0713,
P0717,
P0722,
P0723,
P0962,
P0963,
P0966,
P0967,
P0970,
P0971,
P215C,
P2720,
ECM:
P0101,
P0102,
P0103,
P0106,
P0107,
P0108,
P0171,
P0172,
P0174,
P0175,
P0201,
P0202,
P0203,
P0204,
P0205,
P0206,
P0207,
P0208,
P0300,
P0301,
P0302,
P0303,
P0304,
P0305,
P0306,
P0307,
P0308,
P0401,
P042E
If Transmission
Fluid
Temperature
<= -74 ºC
Sensor = Direct
Proportional
and Temp
If Transmission
Fluid
Temperature
Sensor = >= -74 ºC
Indirect
Proportional
and Temp
Either condition
Fail
above will
>= 60 Time
satisfy the fail
(Sec)
conditions
Test
Failed
This
P0712 Status is
Key On
or Fault
Active
ECM:
None
Transmission Transmission fluid Two
CeTFTI_e_
Fluid temperature Type of Sensor Trips
P0713 = VoltageDir
Temperature thermistor failed at a Used
ectProp
Sensor (TFT) high voltage
If Transmission
Fluid
Temperature
>= 174 ºC
Sensor = Direct
Proportional
and Temp
If Transmission
Fluid
Temperature
Sensor = <= 174 ºC
Indirect
Proportional
and Temp
Either condition
Fail
above will
>= 60 Time
satisfy the fail
(Sec)
conditions
Test
Failed
This
P0713 Status is
Key On
or Fault
Active
ECM:
None
Transmission Transmission Fail One
Input Speed Sensor
Input Speed P0716 Input Speed >= 1350 RPM >= 0.8 Time Trip
Performance
Sensor (TISS) Sensor Drops (Sec)
Test
Failed
This
P0716 Status is not =
Key On
or Fault
Active
ECM:
P0101,
P0102,
P0103,
P0121,
P0122,
P0123
Transmission Fail Fail One
Input Speed Sensor Transmission
Input Speed P0717 Case < 50 RPM >= 4.5 Time Trip
Circuit Low Voltage Input Speed is
Sensor (TISS) 1 (Sec)
Test
Failed
This
P0717 Status is not =
Key On
or Fault
Active
T
Transmission
i i One
Transmission Fail
Output Speed Sensor Output Speed Trip
Output Speed P0722 <= 70 RPM >= 4.5 Time
Circuit Low Voltage Sensor Raw
Sensor (TOSS) (Sec)
Speed
Test
Failed
This
P0722 Status is not =
Key On
or Fault
Active
Transmission Input
= TRUE Boolean
Speed Check
Engine Torque Check = TRUE Boolean
Throttle Position >= 5.0003 Pct
Transmission Fluid
>= -40 ºC
Temperature
Disable this DTC if
= 1 Boolean
the PTO is active
Enable_Flags Defined
Below
Engine Torque
Condition 1
complet
Shift Status is not =
e
OR
Engine Torque
Condition 2
Engine Torque is >= 35 N*m
Engine Torque is <= 1492 N*m
----------------------
The Transmission
Input Speed (TIS)
Check is TRUE, if
either of the two
following conditions
are TRUE
Powertrain Brake
= TRUE Boolean
Pedal is Valid
ECM:
P0101,
P0102,
P0103,
P0121,
P0122,
P0123
One
Transmission Enable
Output Speed Sensor Raw Output Trip
Output Speed P0723 >= 210 RPM >= 0.2 Time
Circuit Intermittent Speed
Sensor (TOSS) (Sec)
Enable
Output Speed
<= 8191 RPM >= 0 Time
Delta
(Sec)
Output
Speed
Drop
Output
p Speed
p
> 650 RPM >
>= 15
1.5 R
Recover
Drop
Fail
Time
(Sec)
----------------------
Range_Disable = FALSE Boolean
OR
----------------------
Neutral_Range_Enabl
= TRUE Boolean
e
And
Neutral_Speed_Enabl
= TRUE Boolean
e
are TRUE
concurrently
----------------------
Transmission_Range
= TRUE Boolean
_Enable
Transmission_Input_
= TRUE Boolean
Speed_Enable
MH2/T43 SECTION Page 151 of 276 3 OF 3 SECTIONS
MH2/T43 SECTION
12 OBDG04 Transmission Diagnostics 3 OF 3 SECTIONS
Component/ Fault Monitor Strategy Malfunction Threshold Secondary Enable Time Mil
System Code Description Criteria Value Malfunction Conditions Required Illum.
No Change in
Transfer Case Range >= 5 Seconds
(High <-> Low) for
Test
Failed
This
P0723 Status is not =
Key On
or Fault
Active
Transmission_Input_
Speed_Enable is
TRUE when either
TIS Condition 1 or TIS
Condition 2 is TRUE:
TIS Condition 1 is
TRUE when both of Enable
the following >= 0 Time
conditions are (Sec)
satsified for
Input Speed Delta <= 4095 RPM
Raw Input Speed >= 500 RPM
Neutral_Range_Enabl
e is TRUE when any
of the next 3
conditions are TRUE
Transmission Range
= Neutral ENUM
is
Revers
e/Neutr
Transmission Range
= al ENUM
is
Transito
nal
Neutral/
Transmission Range Drive
= ENUM
is Transiti
onal
----------------------
Range_Disable is
TRUE when any of
the next three
conditions are TRUE
Transmission Range
= Park ENUM
is
Park/Re
Transmission Range verse
= ENUM
is Transito
nal
Neutral/
Transmission Range Drive
= ENUM
is Transiti
onal
ECM:
P0101,
P0102,
P0103,
P0121,
P0122,
P0123
Torque Enable Two
TCC System Stuck
Converter Clutch P0741 TCC Pressure >= 500 Kpa >= 2 Time Trips
OFF
(TCC) (Sec)
Either Condition
(A) or (B) Must
be Met
Refer to
(A) TCC Slip Fail
Table 1 in
Error @ TCC >= RPM >= 4 Time
Supporting
On Mode (Sec)
Documents
Fail
(B) TCC Slip @
>= 130 RPM >= 4 Time
Lock On Mode
(Sec)
If Above
Conditions
TCC
Have been Met,
Stuck
and Fail Timer >= 3
Off Fail
Expired,
Counter
Increment Fail
Counter
Ignition Voltage Lo >= 8.5996 Volts
Ignition Voltage Hi <= 31.99 Volts
Engine Speed >= 400 RPM
Engine Speed <= 7500 RPM
Test
Failed
This
P0741 Status is
Key On
or Fault
Active
ECM:
P0101,
P0102,
P0103,
P0106,
P0107,
P0108,
P0171,
P0172,
P0174,
P0175,
P0201,
P0202,
P0203,
P0204,
P0204
P0205,
P0206,
P0207,
P0208,
P0300,
P0301,
P0302,
P0303,
P0304,
P0305,
P0306,
P0307,
P0308,
P0401,
P042E
Torque One
TCC System Stuck
Converter Clutch P0742 TCC Slip Speed >= -20 RPM Trip
ON
(TCC)
1st
Current Gear Gear Boolean
Locked
Engine Torque Hi <= 1492 Nm
Engine Torque Lo >= 80 Nm
Current Range Neutral Range
Revers
Current Range Range
e
Transmission Sump
<= 130 ºC
Temperature
Test
Failed
This
P0742 Status is
Key On
or Fault
Active
ECM:
P0101,
P0102,
P0103,
P0106,,
P0107,
P0108,
P0171,
P0172,
P0174,
P0175,
P0201,
P0202,
P0203,
P0204,
P0205,
P0206,
P0207,
P0208,
P0300,
P0301,
P0302,
P0303,
P0304,
High-Side Driver is
= TRUE Boolean
Enabled
Input Speed Sensor
= FALSE Boolean
fault
Output Speed Sensor
= FALSE Boolean
fault
Default Gear Option
= TRUE
is not present
ECM:
P0101,
P0102,
P0103,
P0106,
P0107,
P0108,
P0171,
P0172,
P0174,
P0175,
P0201,
P0202,
P0203,
P0204,
P0205,
P0206,
P0207,
P0208,
Commanded
= 3rd Gear
Gear
Commanded
Gear has
Achieved 1st
Locked OR 1st
F
Free-Wheel
Wh l OR = TRUE B l
Boolean
2nd with Mode
2 Sol.
Commanded
On
C456/CBR1 Pressurize
= Boolean
Pressure Switch d
C456/CBR1
Pressure Switch = FALSE Boolean
Fault
If the above
parameters are
true
Fail One
Mode 2 Multiplex Shift Solenoid Valve B Commanded
P0756 Case = 1st Locked Trip
Valve Stuck Off Gear
1
Please
Refer to
Table 5
Neutral
in
Gear Box Slip >= 200 RPM >= Timer
Supporti
(Sec)
ng
Docume
nts
ECM:
P0101,
P0102,
P0103,
P0106,
P0107,
P0108,
P0171,
P0172,
P0174,
P0175,
P0201,
P0202,
P0203,
P0204,
P0205,
P0206,
P0207,
P0208,
P0300,
P0301,
P0302,
P0303,
P0303
P0304,
P0305,
P0306,
P0307,
P0308,
P0401,
P042E
Fail One
Pressure Control (PC)
Variable Bleed Case Case: Steady Trip
P0776 Solenoid B Stuck Off
Solenoid (VBS) 1 State 3rd Gear
[C35R]
Commanded
= 3rd Gear
Gear
Please
Refer to
Table 5
Neutral
in
Gearbox Slip >= 200 Rpm >= Timer
Supporti
(Sec)
ng
Docume
nts
Intrusive Test:
Command 4th
Gear
Table
Based
Time
If attained
Please Enable
Gear=4th gear >=
Refer to Time (Sec)
for Time
Table 3 in
supporting
documents
It the above
3rd
condiations are
Gear
true, Increment >= 2
Fail
3rd gear fail
Counts
counter
or
3-5R
and C35R Fail Clutch
>= 14
counter Fail
Counts
Fail
Case: Steady
Case
State 5th Gear
2
Commanded
= 5th Gear
Gear
Please
Refer to
Table 5
Neutral
in
Gearbox Slip >= 200 Rpm >= Timer
Supporti
(Sec)
ng
Docume
nts
Intrusive Test:
Command 6th
Gear
Table
Based
Time
If attained
Please Enable
Gear=6th gear >=
Refer to Time (Sec)
Time
Table 3 in
supporting
documents
It the above
5th
condiations are
Gear
true, Increment >= 3
Fail
5th gear fail
Counts
counter
or
3-5R
and C35R Fail Clutch
>= 14
counter Fail
Counts
PRNDL State
= FALSE Boolean
defaulted
inhibit RVT = FALSE Boolean
IMS fault pending
= FALSE Boolean
indication
TPS validity flag = TRUE Boolean
ECM:
P0101,
Fail One
Pressure Control (PC) Case Trip
Variable Bleed Solinoid B Stuck On 1 Case: Steady
P0777
Solenoid (VBS) [C35R] (Steady State 1st
State)
Attained Gear
>= 200 RPM
slip
Table
Based
Time
If the Above is Please Enable
>=
True for Time Refer to Time (Sec)
Table 4 in
supporting
documents
Intrusive test:
(CBR1 clutch
exhausted)
Gear Ratio <= 1.93396
Gear Ratio >= 1.75
If the above
parameters are
true
Fail
>= 0.75 Timer
(Sec)
F il
Fail
Count in
>= 2
1st
Gear
or
Total
>= 3 Fail
Counts
Fail
Case: Steady
Case
State 2nd gear
2
Table
Based
value
Max Delta
Please
Output Speed >= rpm/sec
Refer to
Hysteresis
Table 17 in
supporting
documents
Table
Based
value
Min Delta
Please
Output Speed >= rpm/sec
Refer to
Hysteresis
Table 18 in
supporting
documents
Table
Based
Time
If the Above is Please
>= Sec
True for Time Refer to
Table 19 in
supporting
documents
Intrusive test:
(CB26 clutch
exhausted)
Gear Ratio <= 1.93396
Gear Ratio >= 1.75
If the above
parameters are
true
Table
Based
value
Max Delta
Please
Output Speed >= rpm/sec
Refer to
Hysteresis
Table 17 in
supporting
documents
Table
Based
value
Min Delta
Please
Output Speed >= rpm/sec
Refer to
Hysteresis
Table 18 in
supporting
documents
Table
Based
Time
If the Above is Please
>= Sec
True for Time Refer to
Table 19 in
supporting
documents
Intrusive test:
(C1234 clutch
exhausted)
Gear Ratio <= 1.0500488
Gear Ratio >= 0.9499512
If the above
parameters are
true
Fail
>= 0.75 Timer
(Sec)
F il
Fail
Count in
>= 1
4th
Gear
or
Total
>= 3 Fail
Counts
Fail
Case: Steady
Case
State 6th gear
4
Table
Based
value
Max Delta
Please
Output Speed >= rpm/sec
Refer to
Hysteresis
Table 17 in
supporting
documents
Table
Based
value
Min Delta
Please
Output Speed >= rpm/sec
Refer to
Hysteresis
Table 18 in
supporting
documents
Table
Based
Time
If the Above is Please
>= Sec
True for Time Refer to
Table 19 in
supporting
documents
Intrusive test:
(CB26 clutch
exhausted)
Fail
Gear Ratio <= 1.0500488 >= 0.75 Timer
(Sec)
Gear Ratio >= 0.9499512 >= 1 counts
ECM:
P0101,
P0102,
P0103,
P0106,
P0107,
P0108,
P0171,
P0172,
P0174,
P0175,
P0201,
P0202,
P0203,
P0204,
P0205,
P0206,
Primary
Oncoming Maximum
Clutch Pressure = pressurize
Command d
Status
Primary
Offgoing Clutch Clutch
Pressure = exhaust
Command command
Status
Initial
Range Shift
Clutch
Status
Control
Attained Gear
<= 40 RPM
Slip
If the above
conditions are
true run
appropriate Fail
1 Timers Below:
fail timer 1
Fail Time
(3-1 shifting with >= 1.2001953
(Sec)
Closed Throttle)
fail timer 1
Fail Time
(3-2 shifting with >= 1.2001953
(Sec)
Throttle)
fail timer 1
Fail Time
(3-2 shifting with >= 1.2001953
(Sec)
Closed Throttle)
fail timer 1
Fail Time
(3-4 shifting with >= 1.2001953
(Sec)
Throttle)
fail timer 1
Fail Time
(
(3-4shiftingg with >= 1.2001953
(Sec))
(S
Closed Throttle)
fail timer 1
Fail Time
(3-5 shifting with >= 1.2001953
(Sec)
Throttle)
fail timer 1
Fail Time
(3-5 shifting with >= 1.2001953
(Sec)
Closed Throttle)
fail timer 1
Fail Time
(5-3 shifting with >= 1.2001953
(Sec)
Throttle)
fail timer 1
Fail Time
(5-3 shifting with >= 1.2001953
(Sec)
Closed Throttle)
fail timer 1
Fail Time
(5-4 shifting with >= 1.2001953
(Sec)
Throttle)
fail timer 1
Fail Time
(5-4 shifting with >= 1.2001953
(Sec)
Closed Throttle)
fail timer 1
Fail Time
(5-6 shifting with >= 1.2001953
(Sec)
Throttle)
fail timer 1
Fail Time
(5-6 shifting with >= 1.2001953
(Sec)
Closed Throttle)
Total Fail
Time =
(Fail 1 +
Fail 2)
See
Enable
If Attained Gear Timers
Slip is Less for Fail
than Above Cal >= Timer 1, sec
Increment Fail and
Timers Referenc
e
Supporti
ng Table
15 for
Fail
Timer 2
If fail timer is
greater than
threshold
increment
corresponding
gear fail counter
and total fail
counter
3rd gear
3rd gear fail
>= 3 fail
counter
counts
OR
5th gear
5th gear fail
>= 3 fail
counter
counts
OR
Total fail total fail
>= 5
counter counts
ECM:
P0101,
P0102,
P0103,
P0106,
P0107,
P0108,
P0171,
P0172,
P0174,
P0175,
P0201,
P0202,
P0203,
P0204,
P0205,
P0205
P0206,
P0207,
P0208,
P0300,
P0301,
P0302,
P0303,
P0304,
P0305,
P0306,
P0307,
P0308,
P0401,
P042E
Fail One
Pressure Control (PC)
Variable Bleed Case Case: Steady Trip
P0796 Solenoid C Stuck Off
Solenoid (VBS) 1 State 4th Gear
[C456] (Steady State)
Please
See
Neutral
Table 5
Gear slip >= 200 RPM >= Timer
For
(Sec)
Neutral
Time Cal
Intrusive test:
commanded 5th
gear
Table
Based
Time
If attained Gear Please Enable
>=
5th for time Refer to Time (Sec)
Table 3 in
supporting
documents
if the above
conditions have
been met
4th
Increment 4th
Gear
Gear Fail >= 2
Fail
Counter
Count
OR
C456
and C456 Fail
>= 14 Fail
Counters
Counts
Fail
Case: Steady
Case
State 5th Gear
2
Please
See
Neutral
Table 5
Gear slip >= 200 RPM >= Timer
For
(Sec)
Neutral
Time Cal
Intrusive test:
commanded 6th
gear
Table
Based
Time
If attained Gear Please Enable
>=
6th for time Refer to Time (Sec)
Table 3 in
supporting
documents
if the above
conditions have
been met
5th
Increment 5th
Gear
Gear Fail >= 2
Fail
Counter
Count
OR
C456
and C456 Fail
>= 14 Fail
Counters
Counts
Fail
Case: Steady
Case
State 6th Gear
3
Please
See
Neutral
Table 5
Gear slip >= 200 RPM >= Timer
For
(Sec)
Neutral
Time Cal
Intrusive test:
commanded 5th
gear
Table
Based
Time
If attained Gear Please Enable
>=
5th for time Refer to Time (Sec)
Table 3 in
supporting
documents
if the above
conditions have
been met
Increment 6th
6th
Gear Fail
Gear
Counter and >= 2
Fail
C456 Fail
Count
Counter
OR
C456
and C456 Fail
>= 14 Fail
Counter
Counts
PRNDL State
= FALSE Boolean
defaulted
inhibit RVT = FALSE Boolean
IMS fault pending
= FALSE Boolean
indication
TPS validity flag = TRUE Boolean
ECM:
P0101,
Fail One
Pressure Control (PC)
Variable Bleed Case Case: Steady Trip
P0797 Solenoid C Stuck On
Solenoid (VBS) 1 State 1st
[C456] (Steady State)
Attained Gear
>= 200 RPM
slip
Table
Based
Time
If the Above is Please Enable
>=
True for Time Refer to Time (Sec)
Table 4 in
supporting
documents
Intrusive test:
(CBR1 clutch
exhausted)
Gear Ratio <= 1.4849854
Gear Ratio >= 1.3430176
If the above
parameters are
true
Fail
>= 0.75 Timer
(Sec)
F il
Fail
Count in
>= 2
1st
Gear
or
Total
>= 3 Fail
Counts
Fail
Case
2 Case Steady
State 2nd
Table
Based
value
Max Delta
Please
Output Speed >= rpm/sec
Refer to
Hysteresis
Table 17 in
supporting
documents
Table
Based
value
Min Delta
Please
Output Speed >= rpm/sec
Refer to
Hysteresis
Table 18 in
supporting
documents
Table
Based
Time
If the Above is Please
>= Sec
True for Time Refer to
Table 19 in
supporting
documents
Intrusive test:
(CB26 clutch
exhausted)
Gear Ratio <= 1.4849854
Gear Ratio >= 1.3430176
If the above
parameters are
true
Fail
Case Steady
Case
State 3rd
3
Table
Based
value
Max Delta
Please
Output Speed >= rpm/sec
Refer to
Hysteresis
Table 17 in
supporting
documents
Table
Based
value
Min Delta
Please
Output Speed >= rpm/sec
Refer to
Hysteresis
Table 18 in
supporting
documents
Table
Based
Time
If the Above is Please
>= Sec
True for Time Refer to
Table 19 in
supporting
documents
Intrusive test:
(C35R clutch
exhausted)
Gear Ratio <= 1.4849854
Gear Ratio >= 1.3430176
If the above
parameters are
true
Fail
>= 0.75 Timer
(Sec)
F il
Fail
Count in
>= 1
3rd
Gear
OR
Total
>= 3 Fail
Counts
PRNDL State
= FALSE Boolean
defaulted
inhibit RVT = FALSE Boolean
IMS fault pending
= FALSE Boolean
indication
output speed >= 0 RPM
TPS validity flag = TRUE Boolean
One
Primary Trip
Offgoing Clutch
is exhausted
Pressure Control (PC)
Variable Bleed (See Table 11
P0797 Solenoid C Stuck On = TRUE Boolean
Solenoid (VBS) in Supporting
[C456] (Dynamic)
Documents for
Exhaust Delay
Timers)
Primary
Oncoming Maximum
Clutch Pressure = pressurize
Command d
Status
Primary
Offgoing Clutch Clutch
Pressure = exhaust
Command command
Status
Initial
Range Shift
Clutch
Status
Control
Attained Gear
<= 40 RPM
Slip
If the above
conditions are
true increment
pp p
appropriate Fail
1 Timers Below:
fail timer 1
Fail Time
(4-1 shifting with >= 1.2001953
(Sec)
throttle)
fail timer 1
Fail Time
(4-1 shifting >= 1.2001953
(Sec)
without throttle)
fail timer 1
Fail Time
(4-2 shifting with >= 1.2001953
(Sec)
throttle)
fail timer 1
Fail Time
(4-2 shifting >= 1.2001953
(Sec)
without throttle)
fail timer 1
Fail Time
(4-3 shifting with >= 1.2001953
(Sec)
throttle)
fail timer 1
Fail Time
(4-3 shifting >= 1.2001953
(Sec)
without throttle)
fail timer 1
Fail Time
(5-3 shifting with >= 1.2001953
(Sec)
throttle)
fail timer 1
Fail Time
(5-3 shifting >= 1.2001953
(Sec)
without throttle)
fail timer 1
Fail Time
(6-2 shifting with >= 1.2001953
(Sec)
throttle)
fail timer 1
Fail Time
(6-2 shifting >= 1.2001953
(Sec)
without throttle)
Total Fail
Time =
(Fail 1 +
Fail 2)
See
Enable
If Attained Gear Timers
Slip is Less for Fail
than Above Cal >= Timer 1, sec
Increment Fail and
Timers Referenc
e
Supporti
ng Table
15 for
Fail
Timer 2
If fail timer is
greater than
threshold
increment
corresponding
gear fail counter
and total fail
counter
Fail
Counter
4th gear fail
>= 3 From
counter
4th
Gear
OR
Fail
Counter
5th gear fail
>= 3 From
counter
5th
Gear
OR
Fail
C
Counter
t
6th gear fail
>= 3 From
counter
6th
Gear
OR
Total
Total fail
>= 5 Fail
counter
Counter
ECM:
P0101,
P0102,
P0103,
P0106,
P0107,
P0108,
P0171,
P0172,
P0174,
P0175,
P0201,
P0202,
P0203,
P0204,
P0205,
P0206,
P0207,
Tap Up Switch
Stuck in the Up
Position in = 0 Boolean
Range 2
Enabled
Tap Up Switch
Stuck in the Up
Position in = 0 Boolean
Range 3
Enabled
Tap Up Switch
Stuck in the Up
Position in = 0 Boolean
Range 4
Enabled
Tap Up Switch
Stuck in the Up
Position in = 0 Boolean
Range 5
Enabled
Tap Up Switch
Stuck in the Up
= 1 Boolean
Position in
Neutral Enabled
Tap Up Switch
Stuck in the Up
= 1 Boolean
Position in Park
Enabled
Tap Up Switch
Stuck in the Up
Position in = 0 Boolean
Reverse
Enabled
Fail
Tap Up Switch
= TRUE Boolean >= 1 Time
ON
(Sec)
Tap Up Switch
Stuck in the Up
= 0 Boolean
Position in
Neutral Enabled
Tap Up Switch
Stuck in the Up
= 0 Boolean
P iti iin P
Position Parkk
Enabled
Tap Up Switch
Stuck in the Up
Position in = 0 Boolean
Reverse
Enabled
Tap Up Switch
= TRUE Boolean
ON
NOTE: Both
Fail
Failcase1 and
>= 600 Time
Failcase 2 Must
(Sec)
Be Met
Enable
Time Since Last
>= 1 Time
Range Change
(Sec)
Ignition Voltage Lo >= 8.5996 Volts
Ignition Voltage Hi <= 31.99 Volts
Engine Speed Lo >= 400 RPM
Engine Speed Hi <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
Test
Failed
This
P0815 Status is
Key On
or Fault
Active
ECM:
None
Fail Tap Down Special
Case Switch Stuck in No Trip
Tap Up Tap 1
Downshift Switch the Down
Down Switch P0816 = 0 Boolean
Circuit Position in
(TUTD)
Range 1
Enabled
Tap Down
Switch Stuck in
the Down
= 1 Boolean
Position in
Range Neutral
Enabled
Tap Down
Switch Stuck in
the Down
= 0 Boolean
Position in
Range Reverse
Enabled
Tap Down
= TRUE Boolean >= 1 sec
Switch ON
Tap Down
Switch Stuck in
the Down = 0 Boolean
Position in
Neutral Enabled
Tap Down
Switch Stuck in
the Down = 0 Boolean
Position in Park
Enabled
Tap Down
Switch Stuck in
the Down
= 0 Boolean
Position in
Reverse
Enabled
Tap Down
= TRUE Boolean
Switch ON
NOTE: Both
Failcase1 and
>= 600 sec
Failcase 2 Must
Be Met
Enable
Time Since Last
>= 1 Time
Range Change
(Sec)
Ignition Voltage Lo >= 8.5996 Volts
Ignition Voltage Hi <= 31.99 Volts
Engine Speed Lo >= 400 RPM
Engine Speed Hi <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
Test
Failed
This
P0816 Status is
Key On
or Fault
Active
ECM:
None
Tap Up Tap TUTD Circuit Fail Special
Up and Down Shift
Down Switch P0826 Reads Invalid = TRUE Boolean >= 60 Time No Trip
Switch Circuit
(TUTD) Voltage (Sec)
Ignition Voltage Lo >= 8.5996 Volts
Ignition Voltage Hi <= 31.99 Volts
Engine Speed Lo >= 400 RPM
Engine Speed Hi <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
MH2/T43 SECTION Page 206 of 276 3 OF 3 SECTIONS
MH2/T43 SECTION
12 OBDG04 Transmission Diagnostics 3 OF 3 SECTIONS
Component/ Fault Monitor Strategy Malfunction Threshold Secondary Enable Time Mil
System Code Description Criteria Value Malfunction Conditions Required Illum.
Test
Failed
This
P0826 Status is
Key On
or Fault
Active
ECM:
None
Special
Transmission Fluid No Trip
Transmission
Pressure (TFP) CB26 Hydraulic
Fluid Pressure P0872 <= 50 KPa
Sensor C Circuit Low pressure
Switch
Voltage
Check for
Switch to be in
Exhausted
Fail
Position after >= 18
Counts
delay, If so
then Increment
Fail Counter
Note:
Subsequent fail
counts require
CB26 pressure
above this value
> 50 Kpa
to re-enable fail
logic. Results
in one fail count
per clutch
transition
Transmission Fluid
>= 0 ºC
Temperature Lo
Transmission Fluid
<= 120 ºC
Temperature Hi
Engine Speed is
within the allowable >= 5 Sec
limits for
Default Gear Action = FALSE
High Side Driver ON = TRUE
Hydraulic Pressure
= TRUE
Available
ECM:
None
Check for
Switch to be in
Pressurized
Fail
Position after >= 20
Counts
delay, If so
then Increment
Fail Counter
Note:
Subsequent fail
counts require
CB26 pressure
below this value
< 700 kpa
to re-enable fail
logic. Results
in one fail count
per clutch
transition
Transmission Fluid
>= 0 ºC
Temperature Lo
Transmission Fluid
<= 120 ºC
Temperature Hi
Hydraulic Pressure
= TRUE
Available
Engine Speed Min >= 550 RPM
ECM:
None
Check for
Switch to be in
Exhausted
Fail
Position after >= 5
Counts
delay, If so
then Increment
Fail Counter
Note:
Subsequent fail
counts require
C1234 pressure
above this value
> 50 kpa
to re-enable fail
logic. Results
in one fail count
per clutch
transition
Transmission Fluid
>= 0 ºC
Temperature Lo
Transmission Fluid
<= 120 ºC
Temperature Hi
Engine Speed is
within the allowable >= 5 Sec
limits for
ECM:
None
Check for
Switch to be in
Pressurized
Fail
Position after >= 8
Counts
delay, If so
then Increment
Fail Counter
Note:
Subsequent fail
counts require
C1234 pressure
below this value
< 700 Kpa
to re-enable fail
logic. Results
in one fail count
per clutch
transition
Transmission Fluid
>= 0 ºC
Temperature Lo
Transmission Fluid
<= 120 ºC
Temperature Hi
Engine Speed
S Lo >= 400 RPM
ECM:
None
One
Pressure Control (PC) The HWIO Trip
Fail
Variable Bleed Solenoid A Control reports a low
P0962 = TRUE Boolean >= 0.3 Time
Solenoid (VBS) Circuit Low Voltage voltage (ground
(Sec)
(Line Pressure VBS) short) error flag
Sample
out
0.375 Time
of
(Sec)
Ignition Voltage >= 8.5996 Volts
ECM:
None
One
Pressure Control (PC) The HWIO Trip
Fail
Variable Bleed Solenoid B Control reports a low
P0966 = TRUE Boolean >= 0.3 Time
Solenoid (VBS) Circuit Low Voltage voltage (ground
(Sec)
(C35R VBS) short) error flag
Sample
out
0.375 Time
of
(Sec)
Ignition Voltage >= 8.5996 Volts
Ignition Voltage <= 31.99 Volts
Engine Speed >= 400 RPM
Engine Speed <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
Test
Failed
This
P0966 Status is not =
Key On
or Fault
Active
ECM:
None
One
The HWIO Trip
Pressure Control (PC)
reports a high Fail
Variable Bleed Solenoid B Control
P0967 voltage (open or = TRUE Boolean >= 0.3 Time
Solenoid (VBS) Circuit High Voltage
power short) (Sec)
(C35R VBS)
error flag
Test
Failed
This
P0967 Status is not =
Key On
or Fault
Active
ECM:
None
One
Pressure Control (PC) The HWIO Trip
Fail
Variable Bleed Solenoid C Control reports a low
P0970 = TRUE Boolean >= 0.3 Time
Solenoid (VBS) Circuit Low Voltage voltage (ground
(Sec)
(C456/CBR1 VBS) short) error flag
Sample
out
0.375 Time
of
(Sec)
Test
Failed
This
P0970 Status is not =
Key On
or Fault
Active
ECM:
None
One
The HWIO Trip
Pressure Control (PC)
reports a high Fail
Variable Bleed Solenoid C Control
P0971 voltage (open or = TRUE Boolean >= 0.3 Time
Solenoid (VBS) Circuit High Voltage
power short) (Sec)
(C456/CBR1 VBS)
error flag
Sample
out
0.375 Time
of
(Sec)
Test
Failed
This
P0971 St
Status
t iis nott =
Key On
or Fault
Active
ECM:
None
Sample
out
1.5 Time
of
(Sec)
Test
Failed
This
P0973 Status is not =
Key On
or Fault
Active
ECM:
None
Two
The HWIO Trips
Shift Solenoid A reports a high Fail
Shift Solinoid P0974 Control Circuit High voltage (open or = TRUE Boolean >= 1.2 Time
(Mode 2 Solenoid) power short) (Sec)
error flag
Sample
out
1.5 Time
of
(Sec)
Test
Failed
This
P0974 Status is not =
Key On
or Fault
Active
Two
The HWIO Trips
Shift Solenoid
Mode 3 Multiplex reports a low
P0976 BControl Circuit Low = TRUE Boolean >= 1.2 Sec
Valve g (g
voltage (ground
(Mode 3 Solenoid)
short) error flag
out
1.5 Sec
of
Test
Failed
This
P0976 Status is not =
Key On
or Fault
Active
ECM:
None
One
The HWIO Trip
Shift Solenoid B reports a high
Mode 3 Multiplex
P0977 Control Circuit High voltage (open or = TRUE Boolean >= 1.2 Sec
Valve
(Mode 3 Solenoid) power short)
error flag
out
1.5 Sec
of
Test
Failed
This
P0977 Status is not =
Key On
or Fault
Active
ECM:
None
Transmission Fluid Special
Transmission CBR1/C456
Pressure (TFP) No Trip
Fluid Pressure P0989 Hydraulic <= 50 Kpa
Sensor E Circuit Low
Switch pressure
Voltage
Check for
Switch to be in
Exhausted
Fail
Position after >= 18
Counts
delay, If so
then Increment
Fail Counter
Note:
Subsequent fail
counts require
C35R pressure
above this value
> 50 kpa
to re-enable fail
g
logic. Results
in one fail count
per clutch
transition
Transmission Fluid
>= 0 ºC
Temperature Lo
Transmission Fluid
<= 120 ºC
Temperature Hi
Ignition Voltage Lo >= 8.5996 Volts
Ignition Voltage Hi <= 31.99 Volts
Engine Speed Lo >= 400 RPM
Engine Speed Hi <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
Default Gear Action = FALSE
High Side Driver ON = TRUE
ECM:
None
Check for
Switch to be in
Pressurized
Fail
Position after >= 15
Counts
delay, If so then
Increment Fail
Counter
Note:
Subsequent fail
counts require
C35R pressure
above this value
< 700 kpa
to re-enable fail
logic. Results
in one fail count
per clutch
transition
Transmission Fluid
>= 0 ºC
T
Temperature
t Lo
L
Transmission Fluid
<= 120 ºC
Temperature Hi
Ignition Voltage Lo >= 8.5996 Volts
Ignition Voltage Hi <= 31.99 Volts
Engine Speed Lo >= 400 RPM
Engine Speed Hi <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
Default Gear Action = FALSE
High Side Driver ON = TRUE
ECM:
None
If Slip is Greater
than the Above
Fail
Cal Increment >= 5
Counts
Fail Counter &
Sample Counter
Out Sample
5
of Counts
Calcaluted line
>= 1300 kPa
pressure is
Test is delayed by a
calibrated amount of
time to allow the M2 = 0.5 Sec
valve to get into
position
1st
Current Gear Gear Boolean
Locked
Engine Torque Hi <= 1492 Nm
Engine Torque Lo >= 80 Nm
Current Range Neutral Range
Revers
Current Range Range
e
Transmission Sump
<= 130 ºC
Temperature
Transmission Sump
>= 20 ºC
Temperature
Throttle Position Hyst
>= 8.0002 Pct
High
Throttle Position Hyst
<= 2.9999 Pct
Low
PTO Active = FALSE Boolean
Disable if in D1 and
= 0 Boolean
value true
Disable if in D2 and
= 0 Boolean
value true
Disable if in D3 and
= 0 Boolean
value true
MH2/T43 SECTION Page 227 of 276 3 OF 3 SECTIONS
MH2/T43 SECTION
12 OBDG04 Transmission Diagnostics 3 OF 3 SECTIONS
Component/ Fault Monitor Strategy Malfunction Threshold Secondary Enable Time Mil
System Code Description Criteria Value Malfunction Conditions Required Illum.
Disable if in D4 and
= 0 Boolean
value true
Disable if in D5 and
= 0 Boolean
value true
Disable if in MUMD
= 0 Boolean
and value true
Disable if in TUTD
= 0 Boolean
and value true
4 Wheel Drive Active = FALSE Boolean
Test
Failed
P1751 Status is
This
Key On
ECM:
P0101,
P0102,
P0103,
P0106,
P0107,
P0108,
P0171,
P0172,
P0174,
P0175,
P0201,
P0202,
P0203,
P0204,
P0205,
P0206,
P0207,
P0208,
P0300,
P0301,
P0302,
P0302
P0303,
P0304,
P0305,
P0306,
P0307,
P0308,
P0401,
P042E
Fail One
Internal Mode Switch - Case Trip
Circuit A Low 1
Internal Mode
Reported as Current range = "Transition Range State
Switch (IMS) P182E
Internal Mode Switch- al 1"
Invalid Range
CeTRGR_
Previous range != e_PRNDL_ Range State
Drive6
CeTRGR_
Previous range != e_PRNDL_ Range State
Drive4
Either the S1 or
S3 Pressure
Switch indicates = TRUE Boolean
"Pressure
Present"
If the above
conditions are Fail
present >= 0.225 Second
Increment Fail s
Timer
S3 Pressure
Switch indicates = TRUE Boolean
"Exhausted"
Commanded
= 1st Locked Gear
Gear
Either the S1 or
CeTRG
S3 Pressure
R_e_P
Switch indicates = TRUE Boolean Previous range !=
RNDL_
"Pressure
Drive2
Present"
IMS is
i 7 position
iti
Engine Torque >= -1492 Nm = 0 Boolean
configuration
If the above
conditions are
Second
present >= 0.225
s
Increment Fail
Timer
Either the S1 or
S3 Pressure
Switch indicates = TRUE Boolean
"Pressure
Present"
Steady State
>= 100 Nm
Engine Torque
Steady State
<= 1492 Nm
Engine Torque
If the above
conditions are
Second
present >= 0.225
s
Increment Fail
Timer
If the above
Condtions have
Fail
been met, >= 15
Counts
Increment Fail
Counter
Fail
Case
5 Current range = "Transition
al 11"
Either the S1 or
S3 Pressure
Switch indicates = TRUE Boolean
"Pressure
Present"
If the above
conditions are
Second
present >= 0.225
s
Increment Fail
Timer
If the above
Condtions have
Fail
been met, >= 15
Counts
Increment Fail
Counter
Fail
Case A Open Circuit
6 Definition (flag set
Current range = "Illegal"
false if the following
conditions are met):
"Transiti
or Current Range onal
11"
ECM
Park/Neutral = "Park/Neutr or
Message al"
and Last positive state Neutral
Park,
Neutral,
Reverse,
Current Range Transitiona or
l 8, or
Transitiona
l 11
A Open Circuit
= FALSE Boolean and
(See Definition)
Open
PRNDL Circuit A =
Circuit
Closed
PRNDL Circuit B =
Circuit
Open
PRNDL Circuit C =
Circuit
Open
PRNDL Circuit P =
Circuit
If the above
Condtions are
Second
present, >= 6.25
s
Increment Fail
timer
Fail PRNDL
Case C
Current
t PRNDL circuit
i it
=
7 State ABCP =
1101
and
PRNDL
encoded
Previous valid
= value of Range
state
ABCP
=1111
P182E will
report test fail
when any of the
above 7 fail
cases are met
ECM:
P0101,
P0102,
P0103,
P0106,
P0107,
P0108,
P0171,
P0172,
P0174,
P0175,
P0201,
P0202,
P0203,
P0204,
P0205,
P0206,
P0207,
P0208,
P0300,
The following
events must
occur
Sequentially
Enable
Initial Engine
<= 50 RPM >= 0.25 Time
speed
(Sec)
Then
Th
Engine Speed
Between
Following Cals
Engine Speed
>= 50 RPM
Lo Hist
Enable
Engine Speed
<= 480 RPM >= 0.06875 Time
Hi Hist
(Sec)
Then
Final Engine
>= 525 RPM
Speed
Final Fail
Transmission >= 200 RPM >= 1.25 Time
Input Speed (Sec)
DTC has Ran this Key
= FALSE Boolean
Cycle?
Ignition Voltage Lo >= 6 V
Ignition Voltage Hi <= 31.99 V
Test
Failed
This
P1915 Status is
Key On
or Fault
Active
ECM:
None
Pressure Control (PC) Fail One
Variable Bleed Case: Steady
P2714 Solenoid D Stuck Off Case Trip
Solenoid (VBS) State 2nd Gear
[CB26] 1
Please
See
Neutral
Table 5
Gear slip >= 200 RPM >= Timer
For
(Sec)
Neutral
Time Cal
Intrusive test:
commanded 3rd
gear
Table
Based
Time
If attained Gear Enable
>= Please see
= 3rd for Time Time (Sec)
Table 2 in
Supporting
Documents
If Above
Conditions have
been met
2nd
Increment 2nd Gear
>= 3
gear fail count Fail
Count
or
CB26
and CB26 Fail
>= 14 Fail
Count
Count
Fail
Case: Steady
Case
State 6th Gear
2
Please
See
Neutral
Table 5
Gear slip >= 200 RPM >= Timer
For
(Sec)
Neutral
Time Cal
Intrusive test:
commanded 5th
gear
Table
Based
Time
If attained Gear Enable
>= Please see
= 5th For Time Time (Sec)
Table 2 in
Supporting
Documents
If Above
5th
Conditions have
Gear
been met, >= 3
Fail
Increment 5th
Count
gear fail counter
or
CB26
and CB26 Fail
>= 14 Fail
Count
Count
PRNDL St
State
t
= FALSE Boolean
defaulted
inhibit RVT = FALSE Boolean
IMS fault pending
= FALSE Boolean
indication
TPS validity flag = TRUE Boolean
Hydraulic System
= TRUE Boolean
Pressurized
Minimum output
>= 0 RPM
speed for RVT
A OR B
(A) Output speed
>= 16 RPM
enable
(B) Accelerator Pedal
>= 0.3998 Pct
enable
Common Enable
Criteria
Ignition Voltage Lo >= 8.5996 Volts
Ignition Voltage Hi <= 31.99 Volts
MH2/T43 SECTION Page 239 of 276 3 OF 3 SECTIONS
MH2/T43 SECTION
12 OBDG04 Transmission Diagnostics 3 OF 3 SECTIONS
Component/ Fault Monitor Strategy Malfunction Threshold Secondary Enable Time Mil
System Code Description Criteria Value Malfunction Conditions Required Illum.
Engine Speed Lo >= 400 RPM
Engine Speed Hi <= 7500 RPM
Engine Speed is
within the allowable >= 5 Sec
limits for
Throttle Position
= TRUE Boolean
Signal valid
HSD Enabled = TRUE Boolean
Transmission Fluid
>= 0 ºC
Temperature
Input Speed Sensor
= FALSE Boolean
fault
Output Speed Sensor
= FALSE Boolean
fault
Default Gear Option
= TRUE
is not present
ECM:
P0101,
P0102,
P0103,
P0106,
P0107,
P0108,
P0171,
P0172,
P0174,
P0175,
P0201,
P0202,
P0203,
One
Primary Trip
Offgoing Clutch
is exhausted
Pressure Control (PC)
Variable Bleed (See Table 13
P2715 Solenoid D Stuck On = TRUE Boolean
Solenoid (VBS) in Supporting
[CB26] (Dynamic)
Documents for
Exhaust Delay
Timers)
Primary
Oncoming Maximum
Clutch Pressure = pressurize
Command d
Status
Primary
Offgoing Clutch Clutch
Pressure = exhaust
Command command
Status
Initial
Range Shift
Clutch
Status
Control
Attained Gear
<= 40 RPM
Slip
If above
coditons are
true, increment
appropriate Fail
1 Timers Below:
fail timer 1
Fail Time
(2-1 shifting with >= 1.2001953
(Sec)
throttle)
fail timer 1
Fail Time
(2-1 shifting >= 1.2001953
(Sec)
without throttle)
fail timer 1
Fail Time
(2-3 shifting with >= 1.2001953
(Sec)
throttle)
fail timer 1
Fail Time
(2-3 shifting >= 1.2001953
(Sec)
without throttle)
f il ti
fail timer 1
Fail Time
(2-4 shifting with >= 1.2001953
(Sec)
throttle)
fail timer 1
Fail Time
(2-4 shifting >= 1.2001953
(Sec)
without throttle)
fail timer 1
Fail Time
(6-4 shifting with >= 1.2001953
(Sec)
throttle)
fail timer 1
Fail Time
(6-4 shifting >= 1.2001953
(Sec)
without throttle)
fail timer 1
Fail Time
(6-5 shifting with >= 1.2001953
(Sec)
throttle)
fail timer 1
Fail Time
(6-5 shifting >= 1.2001953
(Sec)
without throttle)
Total Fail
Time =
(Fail 1 +
Fail 2)
See
Enable
If Attained Gear Timers
Slip is Less for Fail
than Above Cal >= Timer 1, sec
Increment Fail and
Timers Referenc
e
Supporti
ng Table
15 for
Fail
Timer 2
If fail timer is
greater than
threshold
increment
corresponding
gear fail counter
and total fail
counter
Fail
Counter
2nd gear fail
>= 3 From
counter
2nd
Gear
OR
Fail One
Case Trip
Pressure Control (PC)
Variable Bleed 1 Case: Steady
P2715 Solenoid D Stuck On
Solenoid (VBS) State 1st
[CB26] (Steady State)
Attained Gear
>= 200 RPM
slip
Table
Based
Time
If the Above is Please Enable
>=
True for Time Refer to Time (Sec)
Table 4 in
supporting
documents
Intrusive test:
(CBR1 clutch
exhausted)
If the above
parameters are
true
F il
Fail
>= 0.75 Timer
(Sec)
Fail
Count in
>= 2
1st
Gear
or
Total
>= 3 Fail
Counts
Fail
Case
Case: Steady
2
State 3rd Gear
Table
Based
value
Max Delta
Please
Output Speed >= rpm/sec
Refer to
Hysteresis
Table 17 in
supporting
documents
Table
Based
value
Min Delta
Please
Output Speed >= rpm/sec
Refer to
Hysteresis
Table 18 in
supporting
documents
Table
Based
Time
If the Above is Please
>= Sec
True for Time Refer to
Table 19 in
supporting
documents
Intrusive test:
(C35R clutch
exhausted)
Gear Ratio <= 3.0159912
Gear Ratio >= 2.7280273
If the above
parameters are
true
Fail
Count in
>= 1
3rd
Gear
or
Total
>= 3 Fail
Counts
Fail
Case: Steady
Case
State 4rd Gear
3
Table
Based
value
Max Delta
Please
Output Speed >= rpm/sec
Refer to
Hysteresis
Table 17 in
supporting
documents
Table
Based
value
Min Delta
Please
Output Speed >= rpm/sec
Refer to
Hysteresis
Table 18 in
supporting
documents
Table
Based
Time
If the Above is Please
>= Sec
True for Time Refer to
Table 19 in
supporting
documents
Intrusive test:
(C1234 clutch
exhausted)
Gear Ratio <= 0.7790527
Gear Ratio >= 0.7049561
If the above
parameters are
true
Fail
>= 0.75 Timer
(Sec)
Fail
Count in
>= 1
4th
Gear
or
Total
>= 3 Fail
Counts
Fail
Case: Steady
Case
State 5th Gear
4
Table
Based
value
Max Delta
Please
Output Speed >= rpm/sec
Refer to
Hysteresis
Table 17 in
supporting
documents
Table
Based
value
Min Delta
Please
Output Speed >= rpm/sec
Refer to
Hysteresis
Table 18 in
supporting
documents
Table
Based
Time
If the Above is Please
>= Sec
True for Time Refer to
Table 19 in
supporting
documents
Intrusive test:
(C35R clutch
exhausted)
Gear Ratio <= 0.7790527
Gear Ratio >= 0.7049561
If the above
parameters are
true
ECM:
P0101,
P0102,
P0103,
P0106,
P0107,
P0108,
P0171,
P0172,
P0174,
P0175,
P0201,
P0202,
P0203,
P0204,
P0205,
One
Pressure Control (PC) The HWIO Trip
Fail
Variable Bleed Solenoid D Control reports a low
P2720 = TRUE Boolean >= 0.3 Time
Solenoid (VBS) Circuit Low voltage (ground
(Sec)
(CB26 VBS) short) error flag
Sample
out
0 375
0.375 Ti
Time
of
(Sec)
Test
Failed
This
P2770 Status is not =
Key On
or Fault
Active
ECM:
None
One
The HWIO Trip
Pressure Control (PC)
reports a high Fail
Variable Bleed Solenoid D Control
P2721 voltage (open or = TRUE Boolean >= 0.3 Time
Solenoid (VBS) Circuit High
power short) (Sec)
(CB26 VBS)
error flag
Sample
out
0.375 Time
of
(Sec)
Test
Failed
This
P2721 Status is not =
Key On
or Fault
Active
ECM:
None
Fail One
Variable Bleed Pressure Control (PC) Case Case: Steady Trip
P2723
Solenoid (VBS) Solenoid E Stuck Off 1 State 1st Gear
Please
See
Neutral
Table 5
Gear slip >= 200 RPM >= Timer
For
(Sec)
Neutral
Time Cal
Intrusive test:
commanded
2nd gear
Table
based
Timer,
If attained Gear Enable
>= Please See
2nd for Time Time (Sec)
Table 3 in
Supporting
Documents
If Ab
Above
1st
Conditions have
Gear
been met, >= 2
Fail
Increment 1st
Count
gear fail counter
or
C1234
and C1234 fail Clutch
>= 14
counter Fail
Count
Fail
Case Case: Steady
2 State 2nd Gear
Please
See
Neutral
Table 5
Gear slip >= 200 RPM >= Timer
For
(Sec)
Neutral
Time Cal
Intrusive test:
commanded 3rd
gear
Table
based
Timer,
If attained Gear Enable
>= Please See
3rd for Time Time (Sec)
Table 3 in
Supporting
Documents
If Ab
Above
2nd
Conditions have
Gear
been met, >= 2
Fail
Increment 2nd
Count
gear fail counter
or
C1234
and C1234 fail Clutch
>= 14
counter Fail
Count
Fail
Case
3 Case: Steady
State 3rd Gear
Please
See
Neutral
Table 5
Gear slip >= 200 RPM >= Timer
For
(Sec)
Neutral
Time Cal
Intrusive test:
commanded 4th
gear
Table
based
Timer,
If attained Gear Enable
>= Please See
4th for time Time (Sec)
Table 3 in
Supporting
Documents
If Ab
Above
3rd
Conditions have
Gear
been met, >= 2
Fail
Increment 3rd
Count
gear fail counter
or
C1234
and C1234 fail Clutch
>= 14
counter Fail
Count
Fail
Case Case: Steady
4 State 4th Gear
Please
See
Neutral
Table 5
Gear slip >= 200 RPM >= Timer
For
(Sec)
Neutral
Time Cal
Intrusive test:
commanded 5th
gear
Table
based
Timer,
If attained Gear Enable
>= Please See
= 5th For Time Time (Sec)
Table 3 in
Supporting
Documents
If Ab
Above
4th
Conditions have
Gear
been met, >= 3
Fail
Increment 4th
Count
gear fail counter
or
C1234
and C1234 fail Clutch
>= 14
counter Fail
Count
PRNDL State
= FALSE Boolean
defaulted
inhibit RVT = FALSE Boolean
IMS fault pending
= FALSE Boolean
indication
TPS validity flag = TRUE Boolean
ECM:
P0101,
One
Primary Trip
Offgoing Clutch
is exhausted
Pressure Control (PC)
Variable Bleed (See Table 10
P2724 Solenoid E Stuck On = TRUE Boolean
Solenoid (VBS) in Supporting
(Dynamic)
Documents for
Exhaust Delay
Timers)
Primary
Oncoming Maximum
Clutch Pressure = pressurize
Command d
Status
Primary
Offgoing Clutch Clutch
Pressure = exhaust
Command command
Status
Initial
Range Shift
Clutch
Status
Control
Attained Gear
<= 40 RPM
Slip
If the above
conditions are
true increment
appropriate Fail
1 Timers Below:
fail timer 1
(2-6 shifting with >= 1.2001953 sec
throttle)
fail timer 1
(2-6 shifting >= 1.2001953 sec
without throttle)
fail timer 1
(3-5 shifting with >= 1.2001953 sec
throttle)
fail timer 1
(3-5 shifting >= 1.2001953 sec
without throttle)
fail timer 1
(4-5 shifting with >= 1.2001953 sec
throttle)
fail timer 1
(4-5 shifting >= 1.2001953 sec
without throttle)
fail timer 1
(4-6 shifting with >= 1.2001953 sec
throttle)
fail timer 1
(4-6 shifting >= 1.2001953 sec
without throttle)
Total Fail
Time =
(Fail 1 +
Fail 2)
See
Enable
If Attained Gear Timers
Slip is Less for Fail
than Above Cal >= Timer 1, sec
Increment Fail and
Timers Referenc
e
Supporti
ng Table
15 for
Fail
Timer 2
If fail timer is
greater than
threshold
increment
corresponding
gear fail counter
and total fail
counter
Fail
Counter
3rd gear fail
>= 3 From
counter
3rd
Gear
Fail
Counter
4th gear fail
>= 3 From
counter
4th
Gear
Total
total fail counter >= 5 Fail
Counter
ECM:
P0101,
P0102,
P0103,
P0106,
P0107,
P0108,
P0171,
P0172,
P0174,
P0175,
P0201,
P0202,
P0203,
P0204,
P0205,
P0206,
P0207,
P0208,
P0300,
P0301,
P0302,
P0303,
P0304,
P0305,
P0306,
P0307,
P0308,
P0401,
P042E
Table
Based
value
Max Delta
Please
Output Speed >= rpm/sec
Refer to
Hysteresis
Table 17 in
supporting
documents
Table
Based
value
Min Delta
Please
Output Speed >= rpm/sec
Refer to
Hysteresis
Table 18 in
supporting
documents
Table
Based
Time
If the Above is Please
>= Sec
True for Time Refer to
Table 19 in
supporting
documents
Intrusive test:
(C35R clutch
exhausted)
Gear Ratio <= 1.4849854
Gear Ratio >= 1.3430176
Fail
Count in
>= 1
5th
Gear
OR
Total
>= 3 Fail
Counts
Fail
Case Case: 6th Gear
2
Table
Based
value
Max Delta
Please
Output Speed >= rpm/sec
Refer to
Hysteresis
Table 17 in
supporting
documents
Table
Based
value
Min Delta
Please
Output Speed >= rpm/sec
Refer to
Hysteresis
Table 18 in
supporting
documents
Table
Based
Time
If the Above is Please
>= Sec
True for Time Refer to
Table 19 in
supporting
documents
Intrusive test:
(CB26 clutch
exhausted)
Gear Ratio <= 1.4849854
Gear Ratio >= 1.3430176
If the above
parameters are
true
Fail
>= 0.75 Timer
(Sec)
F il
Fail
Count in
>= 1
6th
Gear
OR
Total
>= 3 Fail
Counts
PRNDL State
= FALSE Boolean
defaulted
inhibit RVT = FALSE Boolean
IMS fault pending
= FALSE Boolean
indication
output speed >= 0 RPM
TPS validity flag = TRUE Boolean
One
Pressure Control (PC) The HWIO Trip
Fail
Variable Bleed Solenoid E Control reports a low
P2729 = TRUE Boolean >= 0.3 Time
Solenoid (VBS) Circuit Low voltage (ground
(Sec)
(C1234 VBS) short) error flag
Sample
out
0.375 Time
of
(Sec)
Test
Failed
This
P2729 Status is not =
Key On
or Fault
Active
ECM:
None
One
The HWIO Trip
Pressure C
P Control
t l (PC)
reports a high Fail
Variable Bleed Solenoid E Control
P2730 voltage (open or = TRUE Boolean >= 0.3 Time
Solenoid (VBS) Circuit High
power short) (Sec)
(C1234 VBS)
error flag
Sample
out
0.375 Time
of
(Sec)
Test
Failed
This
P2730 Status is not =
Key On
or Fault
Active
ECM:
None
One
The HWIO Trip
reports a low
Fail
Variable Bleed Torque Converter pressure/high
P2763 = TRUE Boolean >= 4.4 Time
Solenoid (VBS) Clutch Pressure High voltage (open or
(Sec)
power short)
error flag
Sample
out
5 Time
of
(Sec)
Test
Failed
This
P2763 Status is not =
Key On
or Fault
Active
ECM:
None
One
The HWIO Trip
Torque Converter
reports a high
Variable Bleed Clutch Pressure
P2764 pressure/low = TRUE Boolean >= 4.4 MPH
Solenoid (VBS) Control Solenoid
voltage (ground
Control Circuit Low
short) error flag
out
5 MPH
of
Test
Failed
This
P2764 Status is not =
Key On
or Fault
Active
ECM:
None
Fail One
CAN Hardware Trip
Controller Area counts
Circuitry
Communication U0073 Network Bus = TRUE Boolean >= 62 (§ 10
Detects a Low
Communication Error seconds
Voltage Error
)
MH2/T43 SECTION Page 272 of 276 3 OF 3 SECTIONS
MH2/T43 SECTION
12 OBDG04 Transmission Diagnostics 3 OF 3 SECTIONS
Component/ Fault Monitor Strategy Malfunction Threshold Secondary Enable Time Mil
System Code Description Criteria Value Malfunction Conditions Required Illum.
Sample
Counts
Out
Delay timer >= 0.1125 sec 70 (§ 11
of
seconds
)
ECM:
None
One
CAN messages Trip
Lost Communications
from ECM are
Communication U0100 with ECM (Engine = TRUE Boolean >= 12 sec
not received by
Control Module)
the TCM
Stabilization delay >=
> 3 sec
Power Mode = Run
Ignition Voltage Lo >= 8.5996 Volt
Ignition Voltage Hi <= 31.99 Volt
ECM:
None
Table 1 Units
Axis 0 64 128 192 256 320 384 448 512 N*m
Curve 50 50 50 50 50 50 50 50 50 RPM
Table 2 Units
Axis -0.007813 0 40 ºC
Curve 409.5938 2 2 Sec
Table 3 Units
Axis -0.007813 0 40 ºC
Curve 409.5938 3.5 3.5 Sec
Table 4 Units
Axis -0.007813 0 40 ºC
Curve 409.5938 2 2 Sec
Table 5 Units
Axis -0.007813 0 40 ºC
Curve 409.5938 3 3 Sec
Table 6 Units
Axis -40 -0.007813 40 80 120 ºC
Curve 409 409 1.6 1.4 1.4 Sec
Table 7 Units
Axis -40 -0.007813 40 80 120 ºC
Curve 409 409 1.4 1.3 1.2 Sec
Table 9 Units
Axis -40 -0.007813 40 80 120 ºC
Curve 409 409 1.3 1.2 1.1 Sec
Table 10 Units
Axis -40 -20 0 30 110 ºC
Curve 3.099609 1.900391 1.099609 0.799805 0.599609 Sec
Table 11 Units
Axis -40 -20 0 30 110 ºC
Curve 1.799805 1.200195 0.599609 0.400391 0.299805 Sec
Table 12 Units
Axis -40 -20 0 30 110 ºC
Curve 2.200195 1.400391 0.900391 0.700195 0.400391 Sec
Table 13 Units
Axis -40 -20 0 30 110 ºC
Curve 2.599609 1 0.5 0.299805 0.200195 Sec
Table 14 Units
Axis -40 -20 0 30 110 ºC
Curve 3 0.900391 0.5 0.299805 0.200195 Sec
Table 15 Units
Axis -40 -30 -20 -10 0 10 20 30 40 ºC
Curve 0 0 0 0 0 0 0 0 0 Sec
Table 16 Units
Axis -0.007813 0 40 ºC
Curve 409.5938 1.5 1.5 Sec
Table 17 Units
Axis -0.007813 0 40 ºC
Curve 8191 1676 1676 Unknown Unit
Table 18 Units
Axis -0.007813 0 40 ºC
Curve 8191 500 500 Unknown Unit
Table 19 Units
Axis -0.007813 0 40 ºC
Curve 0.4 0.35 0.3 Sec
Table 20 Units
Axis -40.10156 -40 -20 0 30 60 100 149 149.1016 ºC
Curve 255.9961 50 45 40 34 25 20 20 255.9961 ºC
Table 21 Units
Axis -40.10156 -40 -20 0 30 60 100 149 149.1016 ºC
Curve 255.9961 50 45 40 34 25 20 20 255.9961 ºC
Table 22 Units
Axis -40.10156 -40 -20 0 30 60 100 149 149.1016 ºC
Curve 255.9961 10 8 8 8 8 8 8 255.9961 ºC