Vous êtes sur la page 1sur 8

LYSAGHT® HR-29TM

About LYSAGHT® HR-29™


Steel Roofing & Walling Profile

PRODUCT PROFILE
®
LYSAGHT HR-29™ profile is a pierce- Proven International Testing /
fastened roofing and walling system Warranted* Quality
that is suitable for classical or
contemporary architecture. It can be • Tested and proven by NATA
rollformed to fit building designs that (National Association of Testing
are either pitched or sprung curved. Authorities, Australia) registered
®
As an added feature, LYSAGHT HR- laboratory in Lysaght Technology
29™ can also be sprung curved to in Chester Hill, Sydney – Australia
accommodate large span roofs. • Tested by CSIRO (Commonwealth
Scientific and Industrial Research
Due to its pierce-fastened system, Organisation – Australia)
®
LYSAGHT HR-29™ profile is fast and • Conforms to International Building
easy to install therefore providing Codes and Standards
savings in construction time and • Manufactured under strict
installation cost. Its on-site rollforming processes certified by MS ISO
option enables ease of installation and 9001:2000 (Quality Management
allows longer lengths to be produced. Product Benefits System) and ISO 14001:1996
®
( E n v i r o n m e n t Management
The high rib depth of LYSAGHT HR- • High ribs with 38mm depth System)
29™ provides excellent stiffness and provide excellent stiffness and • Warranted* by BlueScope Lysaght
hence, optimises the purlins spanning enables greater spanning to ensure reliability and long
capacity while reducing the amount of capability service life
®
purlins used. • Custom cut lengths with the • Genuine LYSAGHT product
option of on-site rollforming allow warranty certificate
Manufactured using BlueScope Steel’s longer spans
®
premium products - ZINCALUME steel • Excellent rainwater drainage
®
and Clean COLORBOND steel, capability MATERIAL SPECIFICATIONS
®
LYSAGHT HR-29™ profile is reliable • Able to be sprung curved to
®
and durable. Additionally, it comes accommodate complicated roof LYSAGHT HR-29™ roofing and
with warranties* to suit different designs walling sheet is available in both
®
environmental conditions and a variety • Manufactured using BlueScope Clean COLORBOND steel and
®
of applications whether they are Steel’s premium products such as ZINCALUME steel. Manufactured
®
industrial, commercial, residential or ZINCALUME steel and Clean using a G550 (550 MPa minimum yield
® ®
institutional. COLORBOND steel to ensure its strength) base steel, the LYSAGHT
durability, reliability and good HR-29™ profile can be rollformed in
looks for years to come standard 0.47mm and non-standard
PRODUCT FEATURES & BENEFITS 0.60mm and 0.80mm total coated
Variety of Choices thickness (TCT).
Product Features
• A range of steel finishes,
• Fixing: pierce-fastened system thicknesses and colours TOLERANCE
enables faster installation to accommodate different
• Net cover width: 730mm (29”) applications and design needs Length : +/- 15mm
width allow easier handling Cover Width : +/- 2mm
• Minimum roof pitch: 2 degrees Thickness : +/- 0.05mm
for a roof with no end lap

2 © August 2005 BlueScope Lysaght


PROFILE DRAWING

PHYSICAL PROPERTIES

Base Metal Total Coated Min


Steel Grade Thickness Thickness Mass Cover Rib Depth Roof
BMT TCT Width Pitch

MPa mm mm kg/m2 mm mm
LYSAGHT® HR-29™ G550 0.42 0.47 4.54 730 38 2°
G550 0.55 0.60 5.86 730 38 2°
G550 0.75 0.80 7.88 730 38 2°

3 © August 2005 BlueScope Lysaght


Performance

SUPPORT SPACING

The maximum recommended support and AS4040.1. Roof spans consider incidental maintenance). Wall spans
spacing are based on testing in both resistance to wind pressure and consider resistance to wind pressure
accordance with AS1562.1, AS4040.0 light foot traffic (traffic arising from only.

Table 1 – Maximum Roof Support Spacing

TCT (mm)
Type of Span
0.47 0.60 0.80
Single Not suitable 1500 2100
End Span 1700 2100 3800
Internal Span 2200 3100 4600
Unstiffened Overhang 150 200 250
Stiffened Overhang 300 350 400

Table 2 – Maximum Wall Support Spacing

TCT (mm)
Type of Span
0.47 0.60 0.80
Single 3600 3600 3600
End Span 3900 3900 3900
Internal Span 4500 4500 4500

* the above tables are based on supports of 1mm


* 0.60mm (TCT) and 0.80mm (TCT) are non-standard thicknesses
* these spacing may vary for particular projects, or areas of high wind speeds

WIND PRESSURE

Table 3 provides the capacities to AS1562.1-1992, “Design and The pressure capacities for strength
of allowable wind pressure for Installation of Sheet Roof and Wall limit state have been determined by
serviceability and strength limit state Cladding”, and AS4040.2-1992, testing the product to failure (ultimate
design. The wind pressure capacities “Resistance to Wind Pressure for Non- load capacity). These pressures are
are based on tests conducted Cyclonic Regions”. applicable to the cladding being fixed
at BlueScope Steel’s NATA registered The serviceability limit state is based to materials of a minimum of 1.0mm in
testing laboratory at Lysaght on a deflection limit of: thickness.
Technology in Sydney, Australia. (span/120) + (p/30),
Testing was conducted in accordance where p is the maximum fastener pitch.

4 © August 2005 BlueScope Lysaght


Table 3 - Wind Pressure Capacities (kPa)

Fasteners Span (mm)


Thickness Type Per Sheet
(mm) of Per Limit
TCT Span Support States 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 4500

Single 4 Serviceability 4.27 3.56 2.89 2.29 1.76 1.33 1.00 0.77 0.60 0.46 - - -
Strength 6.60 5.50 4.60 3.50 2.70 2.10 1.65 1.40 1.25 1.20 - - -

0.47 End 4 Serviceability 4.70 4.03 3.39 2.79 2.25 1.80 1.43 1.15 0.93 0.75 0.60 - -
Strength 7.30 5.75 4.50 3.55 2.80 2.30 1.90 1.70 1.60 1.55 1.50 - -

Internal 4 Serviceability 6.20 5.31 4.44 3.64 2.92 2.32 1.85 1.49 1.24 1.05 0.90 0.79 0.69
Strength 8.10 6.85 5.70 4.65 3.75 3.10 2.65 2.45 2.30 2.20 2.00 1.75 1.50
Single 4 Serviceability 5.56 4.65 3.78 3.00 2.31 1.75 1.32 1.01 0.77 0.58 - - -
Strength 8.35 7.00 5.70 4.55 3.55 2.80 2.20 1.85 1.55 1.40 - - -

0.60 End 4 Serviceability 5.80 5.00 4.24 3.52 2.87 2.33 1.89 1.56 1.30 1.08 0.90 - -
Strength 8.70 7.25 6.10 5.15 4.40 3.80 3.30 2.90 2.65 2.40 2.20 - -

Internal 4 Serviceability 7.00 5.96 4.97 4.06 3.26 2.62 2.15 1.83 1.61 1.43 1.25 1.07 0.89
Strength 9.80 8.60 7.45 6.40 5.45 4.60 3.90 3.30 2.90 2.60 2.35 2.20 2.10
Single 4 Serviceability 10.04 8.15 6.38 4.79 3.44 2.39 1.67 1.23 0.97 0.80 - - -
Strength 12.00 12.00 9.90 7.85 6.15 4.80 3.80 3.20 2.80 2.50 - - -

0.80 End 4 Serviceability 10.90 9.15 7.48 5.92 4.56 3.46 2.46 2.08 1.72 1.47 1.30 - -
Strength 11.00 9.35 8.00 6.85 5.85 5.10 4.40 3.85 3.40 2.95 2.60 - -

Internal 4 Serviceability 12.00 10.10 8.27 6.60 5.14 3.99 3.17 2.63 2.28 2.03 1.79 1.57 1.35
Strength 12.00 10.60 9.20 7.95 6.80 5.80 4.95 4.30 3.80 3.50 3.25 3.10 3.00

RAINWATER RUN OFF FOR LYSAGHT® HR-29™


®
LYSAGHT HR-29™ has better water recommended length for roofing using CSIRO and BlueScope Lysaght testing
®
drainage capacity due to its profile this profile (based on roof slopes of LYSAGHT roofing profiles under
featuring high rib depth. As a guide, and rainfall intensities). These peak rainfall conditions.
Table 4 shows the maximum recommended lengths are based on

Table 4 - Maximum Roof Run (in metres) for Roof Slopes and Rainfall Intensities

Roof Slope (degrees)

Rainfall Intensity (mm/hr) 2º 3º 4º 5º 7.5º 10º


150 136 155 172 187 216 243
200 102 117 129 140 162 182
250 82 93 103 112 130 146
300 68 78 86 93 108 121
400 51 58 64 70 81 91

5 © August 2005 BlueScope Lysaght


Installation Method

Step 1 Step 2

Locate the first roof Check the end of


sheet and make sure roof sheet in relation
the female rib is to overhang for
close to the barge. gutter.

Step 3 Step 4
Fasten screws on Place the second
each rib for single sheet with the
and end spans and f e m a l e r i b o v e r-
every alternate rib lapping the male rib
for internal spans. of the first sheet. The
sheets are snugly
nested at the lap.
Step 5

Vice grips are Step 6


clamped on two
ends. Fasten screws Make periodic check
on the lap of every on alignment after
rib. every 10 sheets.

FASTENING METHODS AND RECOMMENDED FASTENERS

Recommended Fasteners

Location Type of Fixing Details Type of Fastener Drilling Capacity Maximum Attachment
12 - 14 X 55 HGS 6.5mm Maximum 40mm
Roof Crest Fixing 12 - 14 X 68 HGS 6.5mm Maximum 53mm
12 - 14 X 20 HWFS 6.5mm <6mm
Wall Valley Fixing 12 - 14 X 30 HWFS 6.5mm <16mm

Side Lap Fixing 10 - 16 X 16 HWFS 4.5mm 1.2 - 4.5mm

* recommended fastener to conform to AS3566 Class 3 Fastener Spacing

Identification of Fastener Crest Fastening


The format of the number code is: (recommended for roofing)

12 - 14 x 55
Screw gauge Thread pitch Overall length
Trough - Valley Fastening
(Thread (Thread per of the screw (recommended for walling)
outside inch) measured from
diameter) under the head
(mm) Side Lap Fastening
(recommended for roofing)

6 © August 2005 BlueScope Lysaght


Project Reference

Consolidated Farms Berhad’s liquid egg factory in Sungai Buloh, Selangor


®
features LYSAGHT HR-29™ in its roofing and walling.

7 © August 2005 BlueScope Lysaght


Please contact our office in your respective country:

BlueScope Lysaght BlueScope Lysaght BlueScope Lysaght BlueScope Lysaght


(Malaysia) Sdn Bhd (Sabah) Sdn Bhd (Singapore) Pte Ltd (Brunei) Sdn Bhd
No 6, Persiaran Kemajuan Lorong Kurma 18 Benoi Sector Industrial Complex
Seksyen 16, P.O.Box 2222 Off Jalan Kolombong Jurong Town Beribi Phase 1
Pusat Bisnes Bukit Raja 88450 Kota Kinabalu Singapore 629851 6 KM, Jalan Gadong
40800 Shah Alam P.O.Box 12152 Tel: 65-62641577 Bandar Seri Begawan BE1118
Selangor Darul Ehsan, Malaysia 88823 Kota Kinabalu Fax: 65-62650951 Brunei Darussalam
Tel: 603-55192000 Sabah, Malaysia Tel: 673-2447 155
Fax: 603-55105428 Tel: 6088-445161 Fax: 673-2447 154
Fax: 6088-421178
Penang
Tel: 604-390 0853/398 6935 www.bluescopesteel.com.my www.bluescopesteel.com.sg www.bluescopesteel.com.bn
Fax: 604-397 8553

Johor Bahru BlueScope Lysaght


Tel: 607-863 2660/2661 (Sarawak) Sdn Bhd
Fax: 607-863 3661 Lot 610, Section 66
Pending Industrial Area
Pahang Jalan Merbau
Tel: 609-515 7836 93450 Kuching
Fax: 609-515 7834
Sarawak, Malaysia
Kuala Terengganu Tel: 6082-333621
Tel: 609-627 0337 Fax: 6082-483486
Fax: 609-627 0338

www.bluescopesteel.com.my www.bluescopesteel.com.my

Copyright © 2005 by BlueScope Steel Limited. All rights


reserved. No part of this brochure shall be reproduced,
stored in a retrieval system, or transmitted in any form or by
any means, electronic, mechanical, photocopying, recording
or otherwise, without written permission from BlueScope
Steel Limited. LYSAGHT®, ZINCALUME® and COLORBOND®
are registered trade marks and HR-29™ is a trade mark of
BlueScope Steel Limited ABN 16 000 011 058. BlueScope is
a registered trade mark of BlueScope Steel Limited.

* Warranty terms and conditions apply.