Académique Documents
Professionnel Documents
Culture Documents
PRODUCT PROFILE
®
LYSAGHT HR-29™ profile is a pierce- Proven International Testing /
fastened roofing and walling system Warranted* Quality
that is suitable for classical or
contemporary architecture. It can be • Tested and proven by NATA
rollformed to fit building designs that (National Association of Testing
are either pitched or sprung curved. Authorities, Australia) registered
®
As an added feature, LYSAGHT HR- laboratory in Lysaght Technology
29™ can also be sprung curved to in Chester Hill, Sydney – Australia
accommodate large span roofs. • Tested by CSIRO (Commonwealth
Scientific and Industrial Research
Due to its pierce-fastened system, Organisation – Australia)
®
LYSAGHT HR-29™ profile is fast and • Conforms to International Building
easy to install therefore providing Codes and Standards
savings in construction time and • Manufactured under strict
installation cost. Its on-site rollforming processes certified by MS ISO
option enables ease of installation and 9001:2000 (Quality Management
allows longer lengths to be produced. Product Benefits System) and ISO 14001:1996
®
( E n v i r o n m e n t Management
The high rib depth of LYSAGHT HR- • High ribs with 38mm depth System)
29™ provides excellent stiffness and provide excellent stiffness and • Warranted* by BlueScope Lysaght
hence, optimises the purlins spanning enables greater spanning to ensure reliability and long
capacity while reducing the amount of capability service life
®
purlins used. • Custom cut lengths with the • Genuine LYSAGHT product
option of on-site rollforming allow warranty certificate
Manufactured using BlueScope Steel’s longer spans
®
premium products - ZINCALUME steel • Excellent rainwater drainage
®
and Clean COLORBOND steel, capability MATERIAL SPECIFICATIONS
®
LYSAGHT HR-29™ profile is reliable • Able to be sprung curved to
®
and durable. Additionally, it comes accommodate complicated roof LYSAGHT HR-29™ roofing and
with warranties* to suit different designs walling sheet is available in both
®
environmental conditions and a variety • Manufactured using BlueScope Clean COLORBOND steel and
®
of applications whether they are Steel’s premium products such as ZINCALUME steel. Manufactured
®
industrial, commercial, residential or ZINCALUME steel and Clean using a G550 (550 MPa minimum yield
® ®
institutional. COLORBOND steel to ensure its strength) base steel, the LYSAGHT
durability, reliability and good HR-29™ profile can be rollformed in
looks for years to come standard 0.47mm and non-standard
PRODUCT FEATURES & BENEFITS 0.60mm and 0.80mm total coated
Variety of Choices thickness (TCT).
Product Features
• A range of steel finishes,
• Fixing: pierce-fastened system thicknesses and colours TOLERANCE
enables faster installation to accommodate different
• Net cover width: 730mm (29”) applications and design needs Length : +/- 15mm
width allow easier handling Cover Width : +/- 2mm
• Minimum roof pitch: 2 degrees Thickness : +/- 0.05mm
for a roof with no end lap
PHYSICAL PROPERTIES
MPa mm mm kg/m2 mm mm
LYSAGHT® HR-29™ G550 0.42 0.47 4.54 730 38 2°
G550 0.55 0.60 5.86 730 38 2°
G550 0.75 0.80 7.88 730 38 2°
SUPPORT SPACING
The maximum recommended support and AS4040.1. Roof spans consider incidental maintenance). Wall spans
spacing are based on testing in both resistance to wind pressure and consider resistance to wind pressure
accordance with AS1562.1, AS4040.0 light foot traffic (traffic arising from only.
TCT (mm)
Type of Span
0.47 0.60 0.80
Single Not suitable 1500 2100
End Span 1700 2100 3800
Internal Span 2200 3100 4600
Unstiffened Overhang 150 200 250
Stiffened Overhang 300 350 400
TCT (mm)
Type of Span
0.47 0.60 0.80
Single 3600 3600 3600
End Span 3900 3900 3900
Internal Span 4500 4500 4500
WIND PRESSURE
Table 3 provides the capacities to AS1562.1-1992, “Design and The pressure capacities for strength
of allowable wind pressure for Installation of Sheet Roof and Wall limit state have been determined by
serviceability and strength limit state Cladding”, and AS4040.2-1992, testing the product to failure (ultimate
design. The wind pressure capacities “Resistance to Wind Pressure for Non- load capacity). These pressures are
are based on tests conducted Cyclonic Regions”. applicable to the cladding being fixed
at BlueScope Steel’s NATA registered The serviceability limit state is based to materials of a minimum of 1.0mm in
testing laboratory at Lysaght on a deflection limit of: thickness.
Technology in Sydney, Australia. (span/120) + (p/30),
Testing was conducted in accordance where p is the maximum fastener pitch.
Single 4 Serviceability 4.27 3.56 2.89 2.29 1.76 1.33 1.00 0.77 0.60 0.46 - - -
Strength 6.60 5.50 4.60 3.50 2.70 2.10 1.65 1.40 1.25 1.20 - - -
0.47 End 4 Serviceability 4.70 4.03 3.39 2.79 2.25 1.80 1.43 1.15 0.93 0.75 0.60 - -
Strength 7.30 5.75 4.50 3.55 2.80 2.30 1.90 1.70 1.60 1.55 1.50 - -
Internal 4 Serviceability 6.20 5.31 4.44 3.64 2.92 2.32 1.85 1.49 1.24 1.05 0.90 0.79 0.69
Strength 8.10 6.85 5.70 4.65 3.75 3.10 2.65 2.45 2.30 2.20 2.00 1.75 1.50
Single 4 Serviceability 5.56 4.65 3.78 3.00 2.31 1.75 1.32 1.01 0.77 0.58 - - -
Strength 8.35 7.00 5.70 4.55 3.55 2.80 2.20 1.85 1.55 1.40 - - -
0.60 End 4 Serviceability 5.80 5.00 4.24 3.52 2.87 2.33 1.89 1.56 1.30 1.08 0.90 - -
Strength 8.70 7.25 6.10 5.15 4.40 3.80 3.30 2.90 2.65 2.40 2.20 - -
Internal 4 Serviceability 7.00 5.96 4.97 4.06 3.26 2.62 2.15 1.83 1.61 1.43 1.25 1.07 0.89
Strength 9.80 8.60 7.45 6.40 5.45 4.60 3.90 3.30 2.90 2.60 2.35 2.20 2.10
Single 4 Serviceability 10.04 8.15 6.38 4.79 3.44 2.39 1.67 1.23 0.97 0.80 - - -
Strength 12.00 12.00 9.90 7.85 6.15 4.80 3.80 3.20 2.80 2.50 - - -
0.80 End 4 Serviceability 10.90 9.15 7.48 5.92 4.56 3.46 2.46 2.08 1.72 1.47 1.30 - -
Strength 11.00 9.35 8.00 6.85 5.85 5.10 4.40 3.85 3.40 2.95 2.60 - -
Internal 4 Serviceability 12.00 10.10 8.27 6.60 5.14 3.99 3.17 2.63 2.28 2.03 1.79 1.57 1.35
Strength 12.00 10.60 9.20 7.95 6.80 5.80 4.95 4.30 3.80 3.50 3.25 3.10 3.00
Table 4 - Maximum Roof Run (in metres) for Roof Slopes and Rainfall Intensities
Step 1 Step 2
Step 3 Step 4
Fasten screws on Place the second
each rib for single sheet with the
and end spans and f e m a l e r i b o v e r-
every alternate rib lapping the male rib
for internal spans. of the first sheet. The
sheets are snugly
nested at the lap.
Step 5
Recommended Fasteners
Location Type of Fixing Details Type of Fastener Drilling Capacity Maximum Attachment
12 - 14 X 55 HGS 6.5mm Maximum 40mm
Roof Crest Fixing 12 - 14 X 68 HGS 6.5mm Maximum 53mm
12 - 14 X 20 HWFS 6.5mm <6mm
Wall Valley Fixing 12 - 14 X 30 HWFS 6.5mm <16mm
12 - 14 x 55
Screw gauge Thread pitch Overall length
Trough - Valley Fastening
(Thread (Thread per of the screw (recommended for walling)
outside inch) measured from
diameter) under the head
(mm) Side Lap Fastening
(recommended for roofing)
www.bluescopesteel.com.my www.bluescopesteel.com.my