SETUP
Instruction Display Note
0 Show internal A/D Value (Press [CHANGE] key to re-boot the scale)
Instructions: Descriptions
1. Key in [1] → [1] → [0], and then the scale will enter 010 means MRP-15kg / 5g
Calibration Mode automatically.
Weight Calibration
8. Press [CHANGE] key twice Finish setting the data for IC93C46.
when the Span Value is stable.
And then the scale will re-boot
automatically.
Data-Lose: Err-1
1. After switching on the scale, if Display shows [0098] [0400] [Err-1], please key in [0] → [1] →
[0] directly, and then the scale will enter Calibration Mode automatically.
2. If the scale does not enter Calibration Mode, please change a new IC93C46.
3. If the scale cannot be calibrated normally, please make sure if the battery is already under-
voltage.
2. The scale sounds “BiBiBiBiBiBi” three times and three LCD Displays show “- - - - -“ continuously:
The battery has completely run down. Please recharge the battery immediately.