Cumulative Release Notes


Release 5.4.02

July 2018
Optimum Path Inc.

www.optimumpathinc.com
LEGAL NOTICE

Copyright © 1999–2018. Optimum Path Inc. All rights reserved. The contents of this document constitute valuable proprietary
and confidential property of Optimum Path Inc and are provided subject to specific obligations of confidentiality set forth in
one or more binding legal agreements. Any use of this material is limited strictly to the uses specifically authorized in the
applicable license agreement(s) pursuant to which such material has been furnished. Any use or disclosure of all or any part of
this material not specifically authorized in writing by Optimum Path Inc is strictly prohibited.

2
Contact Optimum Path Inc Support
For your convenience, Optimum Path Inc provides one site where you can access the
information that you need for our enterprise products. You can access the resources listed
below by going to https://support.optimumpathinc.com.

• Online and telephone contact information for technical assistance and customer
services
• Product and documentation downloads
• Other helpful resources appropriate for your product

3
Contents
1 Introduction ............................................................................................................................ 5
About This Guide .............................................................................................................. 5
Audience ........................................................................................................................... 5
2 Release Details ........................................................................................................................ 6
Upgrade Patch .................................................................................................................. 6
Upgrade Patch Details............................................................................................... 6
Upgrade Patch Pre-requisites ................................................................................... 6
Upgrade Patch Installation Instructions ................................................................... 7
3 Version 5.4.02 New Features and Enhancements .................................................................. 8
4 Version 5.4.01 New Features and Enhancements ................................................................ 10
5 Version 5.4 New Features and Enhancements ..................................................................... 18

4
1 Introduction
About This Guide
This guide provides detailed information related to the features and enhancements provided in
recent releases of the application.

Audience
This guide is intended for administrators who are responsible for installing, licensing, and
configuring the application.

5
2 Release Details
This version of the product is available as an upgrade patch to the previous release. Please
note the details in the table below for each variation of the installation.

Upgrade Patch
The following details apply to the upgrade patch version of the installation which is applied to
an existing instance of the application only. To perform a new install of the application please
view the New Installation section of this document.
Upgrade Patch Details
Item Description
Name of Install File VDCPatch-180628-C-5.04.00002.tar.bz2
Type of Install File Upgrade
MD5 Checksum 346c2f3ebc0f347152ed13ba16dd9359
Release Date July 3, 2018
Version Affected Version 5.4.0 or higher
Version of 3D Client Required Version 5.4.02

Upgrade Patch Pre-requisites


The following items are required to complete a successful installation of this release.
Please ensure all pre-requisites are met prior to starting any installations of the application.

• WARNING: Before installing this patch, please ensure that ALL VDC servers have at
least one known-good and recent backup and/or VM snapshot to rollback to if
necessary.
• All VDC servers must have version 5.4.0 or higher installed
o Version number is visible on the Web Interface link ribbon bar on the upper left
or
o On the server run: cat /opt/VDC/VERSION
• WARNING: If the VDC system consists of multiple servers, it is vital to install this patch
in the following order:
o Master Database Server first
o then the Master Server
o finally all the Probe Servers
o If the Master Database Server and Master Server reside on the same server,
apply this patch on that server first
• Must have SSH access via a tool like PuTTy to gain command line access on the server

6
• Must have access to the systems using the root user account
• Must have the ability to transfer the patch file to the server (example: WinSCP)
• Confirm the integrity of the patch transfer by comparing the MD5 checksum located in
the Patch Details above:
o After moving the file from your local system to the application server run:
md5sum PATCH_NAME.tar.bz2

Upgrade Patch Installation Instructions


Follow the instructions below to successfully apply this version of the product to your existing
application servers.
WARNING you will presented with the following at the beginning of the installation. Please
ensure that the conditions are met before starting the install.

• Upload PATCH_NAME.tar.bz2 onto all VDC 5.4.0 or higher servers under /tmp/
• Login to all application servers as root user
• Extract the patch installer by running:
o tar -C /opt/VDC -xvf /tmp/PATCH_NAME.tar.bz2
• Apply the patch by running:
o /opt/VDC/patch/PATCH_NAME/install
• Clear browser history after installation before launching VDC v5.4.02

7
3 Version 5.4.02 New Features and Enhancements
The following list of features, enhancements and bug fixes are included in the 5.4.02 version of
the product.

ID Description
2901 SPF Security Acceptance for VDC Tomcat
2945 AD User Login Issue
2946 New Report - Customer List by Power Source
2947 [UWS-841-81854] Empty Exported Report Using Internet Explorer

• 2901 - SPF Security Acceptance for VDC Tomcat


Hardened Tomcat Security
o Loaded Tomcat with the default secure policy created with the Secure Manager
o Implemented strict servlet compliance
o Turned off Session Façade
o Disallowed path delimiter
o Disallowed customer header status messaging
o Created a generic error message html page
o Ensured that the metadata-complete parameter is enabled for applications
o Disallowed deploy on startup
o Reflected cross-site-scripting
o Multiple reflected cross-site-scripting(XSS)
o Stacktraces in Report Servlet

• 2945 - AD User Login Issue


Fixed the AD user login issue.

8
• 2946 - New Report - Customer List by Power Source
Added a new report listing the Floor Power Source devices, Type PDU panel and UPS.

• 2947 - [UWS-841-81854] Empty Exported Report Using Internet Explorer


Fix the issue in Report Creator where export and run report produces an error when
using Internet Explorer.

9
4 Version 5.4.01 New Features and Enhancements
The following list of features, enhancements and bug fixes are included in the 5.4.01 version of
the product.

ID Description
2891 WI: Update System Messages
2908 WI: Verify Function on Target doesn't work
2909 3D: Impact Analysis Issue
2915 WI: CSV Mapping Issue
2918 WI: SFP Ports Not Displayed on Connections tab Rack View
2922 WI: Search enhancement request to support bar-code scanners
2924 3D: Serial number / Asset tag search requirements
2925 WI: A|B Power Report
2926 WI: Performance Enhancement on Connections tab
2927 [YAK-719-15539] Enlogic Discovery Issues
2936 3D: Performance Enhancement on 3D Floor Plan

• 2891 - WI: Update System Messages


o Remove the word “only” in the 10% message, should be same as the 20%
message.

10
o Do not post a message every minute with the same %. If the % is the same, the
message is posted every 30 minutes.

• 2908 - WI: Verify Function on Target doesn't work


The verify function on Target tab doesn’t work. The dropdown list of the following items
on the left is wrong for SNMP configuration. Corrections appear on the right.

11
• 2909 - 3D: Impact Analysis Issue
Impact analysis display issue fixed. Only the impacted devices are displayed with the
correct images.

• 2915 - WI: CSV Mapping Issue


CSC Mapping option is now visible.

12
• 2918 - WI: SFP Ports Not Displayed on Connections tab Rack View
SFP ports and fiber ports are displayed on Connections tab -> Rack View.

• 2922 - WI: Search enhancement request to support bar-code scanners


Add search filters for Asset Tag and Serial Number on Device tab search.

13
• 2924 - 3D: Serial number / Asset Tag search requirements
Add search function for Serial Number and Asset Tag in Project Wizard device search.
Add 2 columns Asset Tag and Serial Number in the device list.

14
• 2925 - WI: A|B Power Report
Reports > Efficiency > A-B Energy Report now displays all the correct data.

• 2926 - WI: Performance Enhancements


o Remove Floor View on Connections tab.
o When users select a rack, the Rack View is displayed.

15
o If users want to see device connections on rack image, click on the device image.

o When users select a device, which is not a rack, device power/network path is
displayed.

16
o When users select a port, the circuit trace on the port is displayed.

• 2927 - [YAK-719-15539] Enlogic Discovery Issues


Multiple issues related to discovering and creating of Enlogic rack PDU devices have
been addressed.

• 2936 - 3D: Performance Enhancement on 3D Floor Plan


Improve 3D floor plan performance to handle 1000+ cable trays.

17
5 Version 5.4 New Features and Enhancements
The following list of features, enhancements and bug fixes are included in the 5.4.00 version of
the product.

ID Description
2550 [AHZ-326-99027] WI: Label text extended beyond the device box
2569 WI: Reserved FMA now visible on Web Floor
2570 WI: Print Floorplan Feature
2590 3D: Clean up the number of icons on the main page of 3D Interface
2591 WI: Changes to how the web interface handles the user session
2594 3D: Floorplan window left and right side tabs have been streamlined
2598 3D session will not time out until you close the 3D client
2616 License Enhancement for Grace Period
2626 3D: Combine Smart Interface and Dashboard
2630 WI: Device Access Tab Functions Moved to Monitor
2633 Limit Ports for Candidate Devices
2634 3D: Show/Hide Functions on the Floorplan Explore Tab Ribbon Streamlined
2668 [HNW-912-71529] Warning Alert not going out after a Back to Normal alert
2710 WI: Remove Server Install Guide from the Help page
2721 3D VDCmon log on Master+Master DB+Probe architecture
2730 WI: Cooling Utilization Report
2799 WI: Add Carbon Emission Factor to web building node
2809 WI: Update RPDU Models to Include Port Index
2810 WI: Update Enlogic PDU Dashboard
2812 Add separate field for the port names for cables
2818 Add Events to Logs for Port Add/Modify/Delete
2820 BACnet Enhancement
2821 WI: Dashboards for Tripp Lite RPDU, RUPS
2822 WI: Add Normal Alarm in Alarm Detail Report
2825 SMTP server timeout setting
2826 [ZBV-180-50397] Sensors to generate humidity and temperature
2827 Add Audit Log Events for Project Wizard
2828 Order Ports by Port Index
2829 WI: Add Delete Function for Attribute Rack Category
2830 Update Power Port Phase
2833 Cable Manager should allow mounting on left or right side of racks
2847 [XXS-520-57530] 3D: Bypass Login Screen
2857 WI: Delete Discovery Jobs in Chrome
2861 [GJX-485-10686] New device name not updated in notification history
2862 Add IP Address in Alarm Notification Email
2863 [SCN-773-70956] Error port not match on import

18
2864 [DVZ-359-98105] WI: Report Logo in 3D
2870 Support Traditional Chinese
2872 [FKA-307-26484] WI: Connected Load Report Modified
2884 Added testweb Script
2885 Update to getsupportinfo.sh Script
2886 3D: Add Hostname on 3D Home Page
2887 3D: Add View/Edit label on 3D Floor Plan
2889 [GBM-996-28880] Trap Configuration is not working
2890 WI: SNMP TCP/UDP protocol

• 2550 [AHZ-326-99027] – WI: Label text extended beyond the device box
The text is now kept inside the device box and does not fully display if there is not
enough space. Users can zoom in on the floor as much as needed to see the full text.

• 2569 – WI: Reserved FMA now visible on Web Floor


Reserved devices are shaded a different color to indicate they are reserved and not
physically placed on the floors on web floor or layers.

19
• 2570 – WI: Print Floorplan Feature
The Print Button (available on home tab, navigation tree floorplan node and floors tab,
floorplan layers sub tab) allows users to print the floor to a high resolution png file
where the complete label for each device is visible. Users can then use their favorite
tools to print the png file to any desired printer.

• 2590 – 3D: Clean up the number of icons on the main page of 3D Interface
The Home Page Ribbon Menu Icons have been consolidated so the full ribbon is visible.

Related functions have been grouped in drop down menus under Project, Main Data
and Search icons.

20
• 2591 – WI: Changes to how the web interface handles the user session
o When the home page is open, users' session will be always active.
o When the home page tab is closed or the browser is closed, the session will be
cleared. The user will be required to enter user name and password when they
open the web page again.
o When the home page tab is closed, the session becomes inactive and all tabs
which were opened from home page will be closed.
o When you logout, all tabs which are opened from home page tab will be closed.

• 2594 – 3D: Floorplan window left and right side tabs have been streamlined
o Devices tab (left) - allows you to search All devices, Available devices or devices
in the Current Location. The search field automatically checks the device name,
asset tag, serial number and IP address attributes for match. The user can fine
tune the search by adding criteria fields to the search. Users can drag devices on
to the floor from the All and Available devices list.

21
o Model tab (left) – allows you to search Models and Model Profiles. The search
function behaves the same as in the Devices tab. Users can create new devices
by dragging a model on to the floorplan, entering a device name, selecting a
device group, Life Cycle and quantity.

o Cable tab (left) – list all the cables for the Current Location. To view selected
cables toggle on the cables from the show/hide cables tool.
o Layer (right) - Displays the layer window so that you can open a layer view. Only
visible when viewing the floor level. Works with Add Layer Map from the Layer
tools in the ribbon bar.
o Dashboards (right) - Displays list of dashboards available for the current view. A
Data Points dashboard will be available showing a list of any data points that
have been monitored for the selected device.
o Trend Charts (right) - Displays list of trend charts available for the current view.
o Alarms (right) - Displays the alarm panel, which shows the active set of alarms
for the current view.
o File Depot/VM - If no device is select on the floor plan the tab shows File Depot
which displays a list of files that you can open, based on the currently selected
view. If a device is selected (device highlighted orange on the floor plan) then the
tab shows VM which displays a list of VMs that are under that device.

22
• 2598 - 3D session will not time out until you close the 3D client
The 3D user session will be not time out automatically. The session is cleared in below
situations:
o Logout from 3D client
o Close 3D application without logout
o Please note that if the 3D client is not closed normally, such as network
disconnect or 3D client crashed, the session may not be cleared.
• 2616 - License Enhancement for Grace Period
A grace period has been added for production licenses. There is now a grace period of 3
working days if the quota is exceeded or the VM moves to a new server. Users now have
time to address the issues before access to the application is terminated. Please see the
VCD 5.4.0 – Administration Guide for complete details.
• 2626 – 3D: Combine Smart Interface and Dashboard Tabs
In the 3D client the smart interface and dashboard tabs have been combined into one
right side tab named Dashboards. It displays a list of dashboards available for the
current view. A Data Points dashboard will be available showing a list of any data points
that have been monitored for the selected device.
• 2630 – WI: Device Access Tab Functions Moved to Monitor
The Access tab has been removed from the Device subtab.

23
The Access protocol details are now managed from the Monitor subtab with the other
monitor protocol configurations.

• 2633 - Limit Ports for Candidate Devices


Users can now filter what ports are available for port mapping by selecting All Ports
(previous and default behavior), Power Ports, Network Ports or Fiber Ports. Only the
desired ports are shown so user can more easily make connections.

24
A Location filter has been added to limit the device display list those at a specific
location.

The same options have been added to the 3D Client Port Mapping function.

• 2634 – 3D: Show/Hide Functions on the Floorplan Explore Tab Ribbon Streamlined
The check boxes to toggle viewing of various elements on the floor are now grouped under
five icons: General, Device Status, Racks, Devices and Cables. The Layer Filter, Generate
Humidity and Generate Thermal icons now indicate status.

25
Layer Filter – The Layer Filter icon indicates if a filter is applied by appearing as Filtered or
Not Filtered

Environment – Generate Humidity and Generate Thermal change to a lighter shade when
on and a corresponding legend appears.

26
• 2668 – [HNW-912-71529] Warning Alert not going out after a Back to Normal alert
When the Notification message is over the limit, VDC detects that there is an incoming
alarm which is higher than the alarm level sent in the last notification message, VDC will
send one and only one more notification message to warn the user that there are incoming
higher level alarms and VDC will not send any more notification messages due to the stop-
to-send threshold being triggered.

• 2710 – WI: Remove Server Install Guide from the Help page
Since the installation guide is needed before the application is installed it has been removed
from the application Help Page. The most up-to-date Server and OS installation guides for
each version is posted in the knowledgebase Visual Data Center > Installer Downloads
section on the support portal.

27
• 2721 - 3D VDCmon log on Master+Master DB+Probe architecture
There is no longer the following error when opening the 3D Log in 3D if the master and
master DB are on different servers.

• 2730 – WI: Cooling Utilization Report


New Cooling Utilization report has been added. It shows the sum of cooling capacity for all
the air conditioner and air handler units on the floor.

• 2799 – WI: Add Carbon Emission Factor to web building node


Carbon Emission Factor has been added to the building node setting in the location builder.
The default value is .676 kg/kW.

28
• 2809 – WI: Update RPDU Models to Include Port Index
RPDU model power out ports should have port index.

• 2810 – WI: Update Enlogic PDU Dashboard

29
• 2812 – Add separate field for the port names for cables
In web and 3D port mapping tool, devices and ports are in separated fields.

• 2818 - Add Events to Logs for Port Add/Modify/Delete


Device ports – added/modified/deleted

Model ports – added/modified/deleted

• 2820 – BACnet Enhancement


Improved management offsetting on the BACnet protocol to accommodate different
customer BACnet configurations.

30
• 2821 – WI: Dashboards for Tripp Lite RPDU, RUPS
Support discovery of Tripp Lite RPDU, RUPS and Air Conditioners.

PDU Dashboard

UPS Dashboard

31
• 2822 – WI: Add Normal Alarm Type in Alarm Detail Report

• 2825 - SMTP server timeout setting


Added a 10 second timeout setting for email SMTP server connection. If the application
doesn’t connect in 10 seconds the application will report the connection failed.
• 2826 – [ZBV-180-50397] Sensors to generate humidity and temperature
o Upon discovery of enlogic iPDU with this group of model, it will auto create child sensor object
based on the OID that OPI is able to discover

o Enhancement of monitor, the name of the attribute can be customized to the


value of an OID. This way, the system should get the name from the OID
(.1.3.6.1.4.1.38446.1.6.2.1.6) that is able to provide the attribute name (temp
and humidity). Also, if Name value queried is temp, it should be in degrees. If
name queried is humidity, it should be %.

32
o After reboot the PDU, the order of the temperature sensor may be changed, so
the unit of the sensor may be changed.

• 2827 - Add Audit Log Events for Project Wizard


Add log events when a project is deleted and work order is completed.

33
• 2828 – Order Ports by Port Index
Outlet ports on PDU – Rackmount are ordered by port index in port mapping. The port
index shows on the tooltip.

Export device will export port index of the ports in Ports table.

34
• 2829 – WI: Add Delete Function for Attribute Rack Category
Rack Category can be added/modified/deleted. There is a cache and it updates every 5
minutes.

• 2830 - Update Power Port Phase


The following power port phases have been updated:

Power Port Type Phase Power Port Type Phase


power inlet BS 546 single-phase power outlet BS 546 single-phase
power inlet CEE 7/16 single-phase power outlet CEE 7/16 single-phase
power inlet CEE 7/17 single-phase power outlet CEE 7/17 single-phase
power inlet CEE 7/4 single-phase power outlet CEE 7/4 single-phase
power inlet CEE 7/5 single-phase power outlet CEE 7/5 single-phase
power inlet CEE 7/7 single-phase power outlet CEE 7/7 single-phase
power inlet IEC 60320 C19 single-phase power outlet IEC 60320 C19 single-phase
power inlet IEC 60320 C20 single-phase power outlet IEC 60320 C20 single-phase
power inlet L6-20 single-phase power outlet L6-20 single-phase
power inlet L6-30 single-phase power outlet L6-30 single-phase
power inlet NEMA L14-30P single-phase power outlet NEMA L14-30P single-phase
power inlet NEMA L14-30R single-phase power outlet NEMA L14-30R single-phase
power inlet NEMA L5-15P three-phase power outlet NEMA L5-15P three-phase
power inlet NEMA L5-15R three-phase power outlet NEMA L5-15R three-phase
power inlet NEMA L5-20P three-phase power outlet NEMA L5-20P three-phase
power inlet NEMA L5-20R three-phase power outlet NEMA L5-20R three-phase
power inlet NEMA L5-30P three-phase power outlet NEMA L5-30P three-phase
power inlet NEMA L5-30R three-phase power outlet NEMA L5-30R three-phase
power inlet NEMA L6-20P single-phase power outlet NEMA L6-20P single-phase
power inlet NEMA L6-20R single-phase power outlet NEMA L6-20R single-phase

35
power inlet NEMA L6-30P single-phase power outlet NEMA L6-30P single-phase
power inlet NEMA L6-30R single-phase power outlet NEMA L6-30R single-phase
power inlet Section 107-2- single-phase power outlet Section 107-2- single-phase
D1 D1
power inlet SEV 1011 three-phase power outlet SEV 1011 three-phase
power inlet SI 32 single-phase power outlet SI 32 single-phase

• 2833 - Cable Manager should allow mounting on left or right side of racks, such as Model
40096-703,40096-703 12" wide
Cable manager can now be mounted on left/right side of racks like RPDU.

• 2847 – [XXS-520-57530] 3D: Bypass Login Screen


A customer now is able to pass user ID, password, and VDC server host name as arguments
to the 3D Client, so that the 3D Client can be launched and logged in automatically.
o Find the installation path of VDC 3D client, for example: C:\Program Files\Visual
Data Center\Visual Data Center 5.4.0

36
o Get encrypt password using the tool below. You can find the tool in the 3D client
installation path. Enter your password and copy the encrypted text the tool
provides.

o Open cmd
o Run: cd C:\Program Files\Visual Data Center\Visual Data Center 5.4.0
o Run: VDC.exe hostname username encryptedpasswordtxt
o If there is only a vdc server configured, Run: VDC.exe username encryptedpasswordtext

• 2857 – WI: Delete Discovery Jobs in Chrome


Users can now delete discovery jobs when using the Chrome browser.

37
• 2861 – [GJX-485-10686] New device name not updated in notification history
Now when a device name is changed the notification history for that device is updated with
the new name.

The device name is 100Wall-RFC-RB001.

Then device name is changed to 100Wall-RFC-RB001-update. Trigger the notification and


the device name is updated in the notification history.

• 2862 - Add IP Address in Alarm Notification Email


IP address has been added to alarm email.

38
• 2863 – [SCN-773-70956] Error port not match on import
If you import a cable for SFP port and don’t add cable type in the import file, the cable can
be imported. The cable type will be determined by the type other port.

• 2864 – [DVZ-359-98105] WI: Report Logo in 3D


Upload a logo to a Company and the logo is used in reports.

The 3D PUE report will use the logo associated with the company.

39
• 2870 – Support Traditional Chinese
Option for Traditional Chinese has been added to login language list.

• 2872 – [FKA-307-26484] WI: Connected Load Report Modified


On the Connected Load report, we added two additional columns, a fourth column showing
actual KW drawn and a fifth column computing the % of connected vs actual drawn.

40
• 2884 – Added testweb Script
This new script verifies that the Tomcat server is running properly, i.e. free from any
internal issues, license issues and permission issues.
o Run: bash /opt/VDC/bin/testweb

• 2885 – Update to getsupportinfo.sh Script


There are now three options for running this key troubleshooting tool.
o /opt/VDC/bin/getsupportinfo.sh
No arguments runs the tool without restarting or starting any services. It takes
approximately 10 minutes to run.
o /opt/VDC/bin/getsupportinfo.sh -S
Collects some additional information and restarts the application processes as
part of its execution. This script will impact production because it restarts
processes and should be used with caution on systems with active users. If the
current application is accessible via the web interface then it is NOT
recommended. If web interface is NOT accessible then use the -S option. It takes
approximately 10 minutes to run.
o /opt/VDC/bin/getsupportinfo.sh -q
Enables “quick mode” where the individual file consistency check is disabled.
Quick mode allows getsupportinfo.sh to finish in 30 seconds instead of 10
minutes.
o All options output to /var/tmp/getsupportinfor.log.bz2

• 2886 – 3D: Add Hostname on 3D Home Page


Display hostname of the VDC server on the 3D home page.

41
• 2887 – 3D: Add View/Edit status on 3D Floor Plan

• 2889 – [GBM-996-28880] WI: Trap Configuration is not working


An attribute named “Specific” has been added. If devices do not have a numeric value in the
Specific field, the trap sender will check the IP Address. If devices have a numeric value in
the Specific attribute, it will check both IP Address and Specific match for trap sender.

• 2890 – WI: SNMP TCP/UDP Protocol


The monitor issue with SNMP TCP protocol has been fixed. The user can now specify UDP or
TCP.

42