Zaxis 220LC GI BUILT-IN DIAGNOSING SYSTEM OPERATION

IMPORTANT: This system is to be operated by the TATA HITACHI Personnel / Dealer Only. Don’t explain this system
function to the customer.
Built-In Diagnosing System Activation
1. While pressing the SET switch, turn the key switch ON.
NOTE: Even if the engine is running, the built-in diagnostic system is operable.
System Operation
1. Each time the display selection switch is pressed, the displayed item will be changed as shown below.

BUILT-IN DIAGNOSING FUNCTION DISPLAY LIST

Display Monitored
Order Description Result Unit Remarks

1 Hour Meter 00000 h Any Standard Mode

Possible to display rpm may


-1
2 Engine Actual Speed n 000 min (rpm) vary as operating conditions

Hydraulic Oil
3 Temperature °C Possible to display

4 L1 E Display Purpose Only

5 Overload Alarm L2 E European Spec. Only

6 Fault Code* 0 E NOT Possible to display

7 ML Switch** 1 E Display Purpose Only

Pump 1 Delivery Possible to display PRESSURE


8 Pressure 2 34.3 Mpa TO 38.3 Mpa MAY VARY AS PER OPERATIONS

Pump 2 Delivery
9 Pressure 3 34.3 Mpa TO 38.3 Mpa Possible to display

Pump 1 Pump (Flow) 1 MPa NEUTRAL 3.8 Mpa During


10 Control Pressure 4 OPERATION - Restriction Possible to display

Pump 2 Pump (Flow) 1 MPa NEUTRAL 3.8 Mpa During


11 Control Pressure 5 OPERATION - Restriction Possible to display

min-1 (rpm) 800 TO 1800 As per


12 Engine Target Speed 6 operations Possible to display

13 EC Angle 7 2.6 V To 3.0 V as per operations Possible to display

Not Possible to display- No


14 Dial Angle 8 0.2 V change in voltage

Technical Training Centre


Zaxis 220LC GI BUILT-IN DIAGNOSING SYSTEM OPERATION
Boom Raise Pilot
15 Pressure 9 3.8 Mpa Possible to display

Arm Roll-In Pilot


16 Pressure A 3.8 Mpa Possible to display

Swing Control Pilot


17 Pressure b 3.8 Mpa Possible to display

Travel Control Pilot


18 Pressure c 3.8 MPa Possible to display

Not Operating :0
19 Front Att. Operation d Operating : 3.8 to 3.9 MPa Possible to display

20 Att. Control Pressure E MPa Not Possible to display

Select Digging mode : 0


Select Att / Breaker 1 : 1

Select Att / Breaker 2 : 1

21 Work Mode F Possible to display

Note: Pressures may vary as per conditions – Power digging control having more pressure than system pressure.

Technical Training Centre