Vous êtes sur la page 1sur 14

GE Medical Systems – Americas: 888-202-5528

P.O. Box 414, Milwaukee, Wisconsin 53201 U.S.A.

LOGIQ P5 Premium GE Ultrasound - Europe: +49-212-28020


P.O. Box 1105 60 D-42665 Solingen
GE Ultrasound - Asia: 65-291-8528

TruScan Imaging Technology Singapore: 298 Tiong Bahru Road, #15-01/06


Tiong Bahru Plaza, Singapore 168730
Internet: http://www.gemedicalsystems.com
Rev4.0.1
October 13, 2010

Product Description
User Interface
The LOGIQ® P5 Premium is a high Operator Keyboard
performance, highly mobile and easy to • Keyboard Width: 43cm
use multipurpose color Doppler Keyboard Height: 84cm
Ultrasound imaging system designed for • Alphanumeric Keyboard
Obstetrical, Gynecological, Cardiac, • Ergonomic Hard Key Operations
Musculoskeletal, Vascular, Urological, • Indicator Lights Identify Activated Keys
Small Parts, Superficial, Pediatric, • Integrated Recording Keys for Remote
Neonatal, Transcranial, Abdominal and Control of Up to 2 Peripheral Devices
other applications. and DICOM Devices
• 8 TGC Pods, with Re-mapping
System Architecture Functionality at Any Depth
Monitor
TruScan™ Architecture – GE’s • 15 inch TFT LCD
innovative, software-intensive platform Electrical Power • XGA Format:
provides exceptional computational
power, image-manipulation capabilities, • Voltage: 100-120Vac or 220-240Vac - Display size: 1024 x 768
real time 4D capabilities, workflow • Frequency: 50/60 Hz - Recording area: 800 x 600
flexibility and product upgradeability. • Power: Max. 750 VA with Built-in and • Adjustable Tilt/Swivel
On-Board Peripherals • Digital Brightness/Contrast Adjustment
TruAccess is the GE advanced, raw-data
processing technology that has helped • Maximum Thermal Output: 2200
transform ultrasound imaging. By BTU/hr.
accessing raw data, TruScan achieves
System Overview
Console Design
excellent image quality and ensures Applications
exceptional image management • 3 Active Probe Ports
capabilities. • Integrated HDD (Capacity: 250GB) • Abdominal
• Integrated DVD-R/W Drive • Obstetrical
SmartScan utilizes new advances in • Gynecological
• On-board Storage for Peripherals (Max
operating algorithms and system • Cardiac
operations to aid in improving image 3 peripherals)
• Wheels • Musculoskeletal
acquisition and patient throughput while
helping to increase diagnostic - Wheel diameter: 12.5cm • Vascular
confidence and exam consistency. - Integrated locking mechanism that • Urological
provides rolling lock and optional • Small Parts and Superficial
ComfortScan, our advanced user-
caster swivel lock • Pediatric and Neonatal
friendly designed software suite helps to
maximize productivity. It simplifies every • Probe Holders, Removable for Cleaning • Transcranial
exam you perform. and Washing Scanning Methods
• Gel Holder, Removable for Cleaning • Electronic Sector
General Specification and Washing • Electronic Convex
• Air Filters, Easily Removable • Electronic Linear
Dimensions and Weight • Front Handle • Mechanical Volume Sweep
• Height: 135/141 cm • Rear Handle (Option)
• Width: 43cm • Drawer (Option) Transducer Types
• Depth: 64cm • Probe Cable Hanger (Option) • Sector Phased Array
• Weight: approx. 75 kg (165 lb.) • Urology Probe Holder (Option) • Convex Array

LOGIQ P5 DOC0518685 Page 1 of 14


• Microconvex Array • Urological Calcs • Simultaneous Capability
• Linear Array • Renal Calcs - B/PW
• Doppler Pencil • Real-time Auto Doppler Calculations - B/CFM or PDI
- B/M
• Bi-plane Microconvex Array • TruAccess, Raw Data Processing
- B + CFM/M
• Real time 4D volume probes • MpegView - Realtime Triplex Mode
• Key Macro (B + CFM or PDI/PW)
Operating Modes
• Network Storage - B-Flow + PW (option)
• B-Mode
• Auto Focus • Dual B (B/B)
• M-Mode - Dual B + CFM or PDI
• Wide Field of View on convex
• Crossbeam • Selectable Alternating Modes
• Simultaneous Display on BE9CS probe
• SRI - B/M
• Quick Save
• Elastography (option) - B/PW
• B-Steer - B + CFM/M
• Anatomical M Mode (option)
• Virtual Convex with X-Beam - B + CFM (PDI)/PW
• Color Flow Mode (CFM)
• ED Report - 3D – Mode
• Power Doppler Imaging (PDI) with
• Flexible Monitor Arm - 3D – Color Mode (option)
Directional Map - B/CW (option)
• PW Doppler with High PRF System Options - B + CFM (PDI)/CW (option)
• B-Flow (option) • Auto IMT • Multi Image Split Screen
• Steered CW Doppler (option) • Elastography - Live and/or frozen
• Dedicated CW Doppler (option) • TVI - B + B/CFM or PDI
• Coded Contrast Imaging (option) • Stress Echo - Independent CINE playback
- Quad screen format
• 3D/4D Volume Modes (option) • DICOM 3.0 Connectivity
• Zoom: Write/Read/Pan
• ECG
System Standard Features • Colorized Image
• Coded Contrast Imaging - Colorized B
• Hard Disk partition of 50GB for image
• CW Doppler - Colorized M
storage
• Anatomical M-Mode - Colorized PW
• Without compression: - Colorized CW (option)
• LOGIQView
• Raw DICOM: HDD capacity 33.000 • Time line Display
• B-Flow
images Independent Dual B/PW Display
• Easy 3D (Baby Face, Vascular)
• DICOM: Display Formats:
• Advanced 3D, with 3D Landscape
- Image Only: HDD capacity 71.000 Top/ Bottom selectable format (Size:
• Real time 4D 1/2:1/2; 1/3:2/3; 2/3:1/3)
images
• 3rd. probe port Side/Side selectable format
• CINE Memory Frames (60 sec) (192MB)
• 3-Pedal Foot Switch, with (1/2:1/2; 1/3:2/3; 0:1)
>1000 depending on probe, imaging
Programmable Functionality Switchable after freeze
depth, line density and field of view
• Rear Handle • TVI
• Real-time Triplex Mode at any Depth
• Drawer • Stress Echo
and PRF • Elastography
• Probe Cable Hanger
• Automatic Optimization
• Urology Probe Holder
- Auto Tissue Optimization: ATO
• 1-Pedal Foot Switch
- Auto Spectrum Optimization: ASO Display Annotation
• Remote Control Switch
- Auto Color Optimization: ACO • 1st. Patient Name: First, Last, &
• Coded harmonic Imaging • PDF report conversion
Middle name each store 27
• Coded Excitation Media & Peripheral Options characters. Up to 62 total characters
• Virtual Convex • Integrated Mounting Kits and Remote displayed.
• Patient Information Database Controls Provided for • 2nd. Patient ID: 31 characters. Up to
• Image Archive on Hard Drive and DVD 27 total characters displayed.
- B/W Digital thermal printer
• Easy Backup for Media • Age, Sex and Birth Date (optional)
- Color Digital thermal printer • Hospital Name: 23 characters.
• Report Designer - DVD Video Recorder • Date: 3 Types selectable
• Vascular Calcs
MM/DD/YY,
• Cardiac Calcs Display Modes DD/MM/YY,
• OB Calcs • Live and Stored Display Format: Full • YY/MM/DD
• Fetal Trending size and split screen - both w/ • Time: 2 types selectable
• Multi Gestational Calcs thumbnails. For Still and CINE • 24 hours, 12 hours
• Hip Dysplasia Calcs • Review Image Format: 4x4, and • Gestational Age from
• Gynecological Calcs "thumbnails". For Still and CINE LMP/EDD/GA/BBT

LOGIQ P5 Page 2 of 14
• Probe Name General System Parameters • Display Format: Full size, 4x4, and
• Gray Map names "thumbnails"
• Probe Orientation • Live image and stored image side-
System Setup
• Depth Scale Marker by-side display
• Pre-programmable Categories
• Lateral Scale Marker • CD-R storage: 650, 700 MB
• User Programmable Preset
• Focal Zone Markers • DVD storage: -R 4,7GB
Capability
• Conversion to MPEG, JPEG, AVI
• Image Depth • Factory Default Preset Data
(SaveAs) and WMV (MPEGvue) file
• Zoom Depth • Languages: English, French, German,
formats
• B-Mode Spanish, Italian, Portuguese, Russian,
• Internal Hard Drive partition of
- Gain Greek, Swedish, Danish, Dutch, Finnish,
50GB for Image Storage
- Dynamic Range Norwegian, Japanese, Chinese
• External USB 2.0 Hard Drive support
- Imaging Frequency • OB Report Format: 5 Types, Tokyo
for Import, Export, DICOM Read, SaveAs
- Edge Enhance Univ., Osaka Univ., USA, Europe, and
and MPEGVue
- Frame Averaging ASUM
• USB 1.1 / 2.0 Memory Stick support
- Gray Map • EFBW: 10 types, Japan, USA and
for SaveAs and MPEGVue
- ATO On/Off Europe (Tokyo Univ., Osaka Univ., Tokyo
• Network Storage support for Import,
• M-Mode Shinozuka, JSUM, German, Shephard,
Export, DICOM Read, SaveAs, MPEGVue
- Gain Merz, Hadlock/Shephard, Williams,
- Dynamic Range Brenner)
- Time Scale • 348 Pre-defined Annotations and Connectivity
• Doppler Mode User Programmable • Ethernet network connection
- Gain Libraries/Annotations • RS-232 serial data output (need a
- Angle • Body Patterns: 140 human types converter cable)
- Sample Volume Depth and Width plus 14 animal types • DICOM 3.0 (option)
- Wall Filter • Customized Comment Home - Verify
- Velocity and/or Frequency Scale Position - Print
- Spectrum Inversion - Store
- Time Scale - Modality Worklist
Complete User Manual available on
- PRF - Storage Commitment
board through Help (F1) - Modality Performed Procedure
- Doppler Frequency User Manual and Service Manual are
• Color Flow Mode Step (MPPS)
included on CD with each system. A - Media Exchange
- Line Density printed Manual is available upon request.
- Frame Averaging - Off network / mobile storage
- Packet Size queue
- Color Scale CINE Memory/Image Memory - Query/Retrieve; supported on
- Color Velocity Range and Baseline • CINE Memory: 192MB Centricity and other compatible
- Color Threshold Marker • Dual Image CINE Display vendors
- Color Gain • Quad Image CINE Display - Structured Reporting; compatible
- PDI • CINE Gauge and CINE Image with LOGIQworks
- Color Scale Inversion Number Display - Public SR Template
- Color Doppler Frequency • CINE Review Loop - Media Store of SR
• TGC Curve • CINE Review Speed: 20 steps (10, 20, - iLinq capability
• Acoustic Frame Rate 30, 40, 50, 60, 70, 80, 90, 100, 150, 200,
• Cine Frame Number 300, 400, 500, 600, 700, 800, 900, Scanning Parameters
• VCR Counter 1000%)
• VCR Status • Selectable CINE Sequence for CINE • Digital Beamformer
• VCR Playback Counter Review • 2560 processing channels
• Body Pattern • Measurements, Calculations and • Frame Rate: > 700 depending on
• Application Name Annotations on CINE Playback preset
• Measurement Results • Scrolling Timeline Memory • Displayed Imaging Depth: 0 – 30 cm
• Operator Message • Cine Capture Function • Minimum Depth of Field: 0 –2cm
• Displayed Acoustic Output (probe dependent)
- TIS: Thermal Index Soft Tissue Image Storage • Maximum Depth of Field: 0 – 30 cm
- TIC: Thermal Index Cranial (Bone) • On-board database of patient (probe dependent)
- TIB: Thermal Index Bone information from past exams • Transmission Focus
- MI: Mechanical Index • Storage Format: DICOM/Raw Data • 1 – 8 Focus Points Selectable (probe
• % of Power output • DICOM Still Image Storage Size: and application dependent)
• Biopsy Guide Line and/or Zone - Gray Image: ~300K to ~1.3 MB Focal Zone Position, B-Mode 16
• Heart Rate - Color Image: ~900K to 1.9 MB steps, CFM 64 steps
• Multiframe • Multi-Frequency/Wideband

LOGIQ P5 Page 3 of 14
Technology • Line Density: 5 steps • Dynamic Range: 30 – 120 dB, 3 dB
• Frequency Range 1 to 13MHz • Line Density Zoom: 5 steps step
• 256 Shades of Gray • Frame Average: 7 steps • Edge Enhance: 6 steps
• Up to 197 db processing dynamic • PRF: 280 Hz – 19600 Hz • Gray Scale Map: 23 types
range • Spatial Filter: 6 steps • Clear Map: 23 types
• 16,777,216 Hues of Color • Gain: 0 – 40 dB, 0.5 dB step • M Gain: 0 – 98 dB, 2 dB step
• Adjustable Field of View (FOV) up to • Wall Filter:4 steps depend on
170 degree depending on probe probe/application Anatomical M-Mode
• Image Reverse: Right/Left • Scanning Size (FOV or Angle): probe M-mode cursor adjustable at any
• Image Rotation: 4 steps dependent plane
Rotation: 0°, 90°, 180°, 270° • CF/PDI Vertical Size (mm) of ROI: Can be activated from a CINE loop
default pre-settable from a live or stored image
B-Mode • CF/PDI Center Depth (mm) of ROI: Available with Color Flow Mode
• B/M Acoustic Output: 0 – 100%, default pre-settable M & A capability
2% step • CF/PDI Frequency: Up to 3 steps,
• Image Reverse: On/Off depend on probe PW/CW-Mode
• B Color: 10 types • Color Map: 20 types depend on • Maximum and Minimum Velocity
application Scales
• Thermal Index: TIC, TIS, TIB
• Transparent: 5 steps - Max: 10 m/sec
• Softener: 4 steps
• Color Threshold: 0 – 100 %, 5 % step - Min: 5 cm/sec
• Focus Number: 8 steps • Auto Line Density: On/Off pre-
• Focus Width: 3 types • Gray Scale Map: 4 types
settable • Dynamic Range: 24 – 60, 4 dB step
• Range Focus: On/Off • PW/CF Ratio: 1, 2, 4
• Compression: 0.5 – 1.5, 0.1 step • Base Line: 5 – 95 %, 11 steps
• Accumulation: 8 steps • SV Gate: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 12,
• Line Density: 4 steps
14, 16 mm
• Line Density Zoom: 4 steps Power Doppler Imaging • Angle Correct: +/- 90°, 1° step
• Suppression: 6 steps • PDI Map: 13 types • Spectral Color: 6 types
• Frame Average: 8 steps • CF/PDI Flash Suppression: 2 steps • PW Sweep Speed: 8 steps
• Edge Enhance: 6 steps • CF/PDI Focus Depth: default pre- • Invert: On/Off
• Scanning Size (FOV or Angle): settable for 0 – 100 % of ROI in depth, • M/PW Display Format: V-1/3B, V-
probe dependent, see probe 10 % step 1/2B, V-2/3B, H-1/2B, H-1/4B, TL only
specifications • CF/PDI Acoustic Output: 0 – 100%, • Duplex: On/Off(PW only)
• Gray Scale Map: 23 types 10% step • PW Acoustic Output: 0 – 100 %,
• Clear Map: 23 types • CF/PDI Angle Steer: 0, +/- 20° 10 % step
• Tint Map: 10 types • Packet Size: 5 – 16, dependent on • Spectral Averaging: 4 steps
• Gain: 0 – 98 dB, 2 dB step probe/application • Time Resolution: 4 steps
• Dynamic Range: 30 – 120 dB, 3 dB • Spatial Filter: 6 steps • PW/CF Ratio: 1, 2, 4
step • Frame Average: 7 steps • Rejection: 15 steps
• Depth: 1 – 30 cm, 1 cm step, • PRF: 280 Hz – 19600 Hz • Gain: 0 – 32 dB, 1 dB step
depend on probe. • Power Threshold: 0 – 100 %, 5 % • Wall Filter: 5 – 1500 Hz, 22 steps,
• Rejection: 6 steps step depend on probe/application
• Frequency: Up to 5 steps, depend • Gain: 0 – 40 dB, 0.5 dB step • PW Angle Steer: 0, +/- 5, 10, 15, 20°
on probe • Wall Filter: 7 steps depend on • PRF: 640 – 29800 Hz with PW, 50000
probe/application Hz with CW
• CF/PDI Frequency: Up to 3 steps, • Sample Volume Depth: 29 steps
• Auto Line Density: On/Off pre-
depend on probe default pre-settable
settable
• Auto Line Density: On/Off pre- • CW-Mode (option) is Available on
• Steered Linear: +/- 15°
settable the Following Probes
• Transparent: 5 steps - 3S
Color Flow Mode • Invert: On/Off - 5S
• Base Line: 0 – 100 %, 10 % step • Accumulation: 8 steps - 7S
• Invert: On/Off - 3Sp
• CF/PDI Focus Depth: default pre-
M-Mode - 5Sp
settable for 0 – 100 % of ROI in depth, - P2D
• Sweep Speed: 8 steps
10 % step - P6D
• M Color: 10 types
• CF/PDI Flash Suppression: 2 steps
• M/PW Display Format: V-1/3B, V-
• CF/PDI Acoustic Output: 0 – 100%,
10% step
1/2B, V-2/3B, H-1/2B, H-1/4B, TL only Coded Harmonic Imaging
• B/M Acoustic Output: 0 – 100 %, 2 % • Available on the Following Probes
• CF/PDI Angle Steer: 0, +/- 20°
step - 3.5C
• Packet Size: 5 – 16, dependent on
• Rejection: 6 steps - 3.5CS
probe/application

LOGIQ P5 Page 4 of 14
- 3CRF - T739 2 types, Available on 3.5C and 3.5CS
- 4C - I739 probes
- 5CS - 3S 3 type, Available on 4C, 5CS probes
- E8C - 5S - Tissue Background Selection: 4
- E8CS - 7S steps
- 8C - 3Sp • Time Trigger Scan: 0.3, & 0.5 – 10
- ERB - 5Sp sec, 0.5 sec step
- BE9CS - ERB - Linear • Time Intensity Curve Analysis
- 3S - 4C • Accumulation: 8 steps
- 5S - 5CS • SRI-HD
- 7S - 4D3C-L The LOGIQ P5 is designed for
- 3Sp - 3CRF compatibility with commercially
- 5Sp available ultrasound contrast agents.
- 8L Automatic Optimization Because the availability of these agents
- 9L • Optimize B-Mode, B-Flow image to is subject to government regulation and
- 11L improve contrast resolution. approval, product features intended for
- i12L • Selectable amount of contrast use with these agents may not be
- i739 resolution improvement (low, medium, commercially marketed nor made
- T739 high) available before the contrast agent is
- 4D3C-L • Auto-TGC in B-Mode and Color – cleared for use. Contrast related product
- 4DE7C adjusts overall and axial gain features are enabled only on systems for
- 4D8C • Optimize Spectral Waveform – delivery to an authorized country or
• Softener: 4 steps adjusts baseline, invert, PRF (on live region of use. GE Medical Systems
• Line Density: 4 steps image), and angle correction makes no claims concerning the safety
• Line Density Zoom: 4 steps • Algorithm works on focal zone/ or effectiveness of contrast agents.
• Suppression: 6 steps number and depth changes
• Edge Enhance: 6 steps • Available on stored or live image Elastography Mode (option)
• Gray Scale Map: 23 types • Available in B-Mode, B-Flow, PW • Elasto Acoustic Output: 0 – 100%
• Clear Map: 23 types Doppler, Color • Line Density
• Tint Map: 10 types • Elasto Frequency
• Gain: 0 – 98 dB, 2 dB step • Frame Average
B-Flow (option)
• Dynamic Range: 30 – 120 dB, 3 dB • Axial Smoothing
• Available on 8L, 9L, 10L, 11L, i739
step • Later Smoothing
and T739 Probes
• Rejection: 6 steps • Window
• Background: On/Off
• Auto Line Density: On/Off pre- • Frame Reject
• Sensitivity/PRI: 14 steps
settable • Noise Reject
• Line Density: 4 steps
• Frequency: Up to 5 steps, depend on • Transparency Map
• Edge Enhance: 6 steps
probe • Color and Gray Map
• Frame Average: 8 steps
• Gray Scale Map: 23 types • Soft Compress
Coded Excitation • Clear Map: 23 types • Hard Compress
• Available on the following probes • Tint Map: 10 types • Quality Graph : On/Off
the Following Probes • Dynamic Range: 30 – 120 dB, 3 dB • Available on the following Probes
- 11L step • 11L
- 12L • Rejection: 6 steps
- 8C • Gain: 0 – 98 dB, 2 dB step
- E8C • Auto Line Density: On/Off pre- Auto IMT (option)
- E8CS settable • Automated measurement of the
- BE9CS • Accumulation: 8 steps intimae media thickness of common
- ERB carotid artery
Coded Contrast Imaging (option) Result window displayed on screen
Virtual Convex • Coded Harmonic Angio: Available on
• Provides a Convex Field of View for 3.5C, 3.5CS, 4C and 5CSprobes TVI (option)
Convex, Linear and Sector probes - Tissue Background Selection: 4 • Myocardial Doppler Imaging with
• Available on the Following Probes steps color overlay on tissue image
- 8L • TruAgent Detection: Available on • Available on all sector probes
- 9L 3.5C, 3.5CS, 4C and 5CS probes • Tissue color overlay can be
- 10L - 2 frequencies on 3.5C and 3.5CS, 1 removed to show just the 2D image,
- 11L on 4C and 5CS probes still retaining the tissue velocity
- 12L • Coded Phase Inversion: information
- i12L

LOGIQ P5 Page 5 of 14
• Anatomical M-mode: free CrossBeam • Scalpel: 3D Cut tool
placement of M-mode generated from • Provides Spatial Compounding • Display Format:
the cursor independent from the axial • Available on the linear and convex - Quad: A-/B-/C-Plane/3D
plane probes - Dual: A-Plane/3D
• Q-Analysis: Multiple Time -Motion - 3CRF - Single: 3D or A- or B- or C-Plane
trace display from selected points in - 4C
the myocardium - 5CS
- 8C Pre-Processing
Stress Echo Package (option) - E8C • Write Zoom up to 8x
• Advanced and flexible stress-echo - E8CS • B/M-Mode
examination capabilities - 8L - Gain
• Provides exercise and - 9L - TGC
pharmacological protocol templates - 11L - Acoustic Output
- 6 default templates - I12L - Transmission Focus Position
• Template editor for user - I739 - Transmission Focus Number
configuration of existing templates or - T739 - Transmission Focus Width
creation of new templates - BE9CS - Imaging Frequency
• Reference scan display during - 4D3C-L - Edge Enhancement
acquisition for stress level comparison - 4DE7C - Line Density Control
(dual screen) - 4D8C - Live Anatomical M-mode
- Baseline level/Previous level - ERB
selectable • PW/CW-Mode
• Raw data continuous capture • Provides 3, 5 or 7 angles for - Gain
- Over 180 sec available Compounding on Linear probes, 3 or 5 - Dynamic Range
• Wall motion scoring (bulls-eye and angles on Convex probes - Acoustic Output
segmental) • Compatible with Side by Side - Doppler Frequency
Display - Velocity Scale (PRF)
• Compatible with: Color mode, - PW/CF Ratio
LOGIQView (option) Timeline mode, SRI-HD, Coded - Wall Filter
• Available on all probes Harmonic Imaging, Virtual Convex - Time Resolution
• Extended Field of View Imaging • - Sample Volume Gate for PW-
• For use in B-Mode SRI-HD Mode
• LOGIQView Status • High Definition Speckle Reduction Length
• Auto detection of scan direction Imaging Depth
• Pre or post-process zoom up to 10X • Provides 6 levels of speckle • Color Flow Mode
• Rotation reduction - CFM Gain
• Auto best fit on monitor • Side by Side Display - CFM Velocity Scale (PRF)
• Measurements in B-Mode • Compatible with ALL linear, convex - Acoustic Output
• Up to 60 cm scan length and sector transducers - CFM Frequency
• Compatible with ALL scanning - Wall Filter
Easy 3D (option) mode - Packet Size
Colorize • Compatible with Side by Side - CFM Spatial Filter
Threshold (Opacification) Display - CFM Line Density
Render - CFM Regression Filter
Texture Real Time 4D (option) - Accumulation
• Acquisition Modes:
Gray Surface
- Realtime 4D Bmode Post-Processing w/ TruAccess (Raw
Scalpel - Static 3D Bmode Data)
Auto Movie • Visualization Modes: • SRI-HD – Selectable level of Speckle
Undo - 3D Rendering (diverse surface and Reduction Imaging
Reset intensity projection modes) • Max Read Zoom to 16x
- Sectional Planes (3 Section planes • B/M-Mode
Advanced 3D (option) perpendicular to each other) - ATO (Auto Tissue Optimization)
• Acquisition of Color data • Render Mode: - Image Reverse
• Automatic rendering - Surface texture, Surface Smooth, - Image Rotation
• 3D Landscape technology max-, min- and X-ray (average - Gray Map
• 3D Movie intensity projection), Gradient, - Colorized B and M
• Main Mode Inversion, Glass Body, Mix Mode of - Gain
two render Modes - Dynamic Range
• Curved 3point Render start - TGC
• 3D Movie

LOGIQ P5 Page 6 of 14
- Compression • Heart Rate - TCD (Transverse Cerebellum
- Rejection Diameter)
- Frame Averaging General Doppler - THD (Thorax Transverse Diameter)
- B Softener Measurements/Calculations - TIB (Tibia Length)
- Suppression • Velocity - ULNA (Ulna Length)
- Sweep Speed for M-Mode • Time • Estimated Fetal Weight (EFW) by:
- Anatomical M Mode • A/B Ratio (Velocities / Frequency - AC, BPD
• PW/CW-Mode Ratio - AC, BPD, FL
- ASO (Auto Spectral Optimization) • PS (Peak Systole) - AC, BPD, FL, HC
- Base Line Shift • ED (End Diastole) - AC, FL
- Gray Map • PS/ED (PS/ED Ratio) - AC, FL, HC
- Post Gain • ED/PS (ED/PS Ratio) - AC, HC
- Compression • AT (Acceleration Time) • Calculations and Ratios
- Rejection • ACCEL (Acceleration) - FL/BPD
- Spectral Averaging • TAMAX (Time Averaged Maximum - FL/AC
- Colorized D Velocity - FL/HC
- Display Format • Volume Flow (TAMEAN and Vessel - HC/AC
- Sweep Speed Area) - CI (Cephalic Index)
• Color Flow Mode • Heart Rate - AFI (Amniotic Fluid Index)
- ACO (Auto Color Optimization) • PI (Pulsatility Index) • Measurements / Calculations by:
- Base Line Shift • RI (Resistivity Index) Jeanty, Merz, Tokyo University, Mercer,
- Color Map Hansmann, Erickson, Hill, Shephard,
- Post Gain Hadlock, Hohler, Campbell
Real-time Doppler Auto
- Frame Averaging • Fetal Graphical Trending
- CFM Display Threshold Measurements / Calculations • Growth Percentiles
- Angle Correct (PW mode) • PS (Peak Systole) • Multi-Gestational Calculations (4)
- Quick Angle Correct (PW mode) • ED (End Diastole) • Fetal Qualitative Description
- Auto Angle Correct (PW mode) • MD (Minimum Diastole) (Anatomical survey)
- Spectral Invert for Color and • PI (Pulsatility Index) • Fetal Environmental Description
Doppler • RI (Resistivity Index) (Biophysical profile)
• 3D reconstruction from a stored • AT (Acceleration Time) • Programmable OB Tables
CINE loop • ACC (Acceleration) • Over 20 selectable OB Calcs
• Anatomical M-Mode • PS/ED (PS/ED Ratio) • Expanded Worksheets
• Accumulation • ED/PS (ED/PS Ratio)
• Cine Capture • HR (Heart Rate)
GYN Measurements/Calculations
• TAMAX (Time Averaged Maximum
• Right Ovary Length, Width, Height
Physiological Input Panel (Option) Velocity)
• Left Ovary Length, Width, Height
• PVAL (Peak Velocity Value)
• Physiological Input • Uterus Length, Width, Height
• Volume Flow (TAMEAN and Vessel
- ECG, 1 channel • Ovarian Volume
Area)
• Dual R-Trigger • ENDO (Endometrial thickness)
• Pre-settable ECG R Delay Time • Ovarian RI
• Pre-settable ECG Position OB Measurements/Calculations • Uterine RI
• Adjustable ECG Gain Control • Gestational Age by: • Follicular measurements
• Automatic Heart Rate Display - GS (Gestational Sac) • Summary Reports
- CRL (Crown Rump Length)
- FL (Femur Length)
Measurements / Calculations - BPD (Biparietal Diameter)
Vascular
- AC (Abdominal Circumference) Measurements/Calculations
General B-Mode - HC (Head Circumference) • SYS DCCA (Systolic Distal Common
• Depth & Distance - APTD x TTD (Anterior/Posterior Carotid Artery)
• Circumference (Ellipse / Trace) Trunk Diameter by Transverse Trunk • DIAS DCCA (Diastolic Distal Common
• Area (Ellipse / Trace) Diameter) Carotid Artery)
• Volume (Ellipsoid) - LV (Length of Vertebra) • SYS MCCA (Systolic Mid Common
• % Stenosis (Area or Diameter) - FTA (Fetal Trunk Cross-sectional Carotid Artery)
• Angle between two lines Area) • DIAS MCCA (Diastolic Mid Common
- HL (Humerus Length) Carotid Artery)
General M-Mode - BD (Binocular Distance) • SYS PCCA (Systolic Proximal
• M-Depth - FT (Foot Length) Common Carotid Artery)
• Distance - OFD (Occipital Frontal Diameter) • DIAS PCCA (Diastolic Proximal
• Time - TAD (Transverse Abdominal Common Carotid Artery)
• Slope Diameter)

LOGIQ P5 Page 7 of 14
• SYS DICA (Systolic Distal Internal Left Ventricle Mass (LVPWd, LVPWs) Pulmonic Valve Area (PV Planimetry)
Carotid Artery) Left Ventricle Volume, Teichholz/Cubic Pulmonic Valve Annulus Diameter (PV
• DIAS DICA (Systolic Distal Internal (LVIDd, LVI Ds) Annulus Diam)
Carotid Artery)
Left Ventricle Internal Diameter (LVIDd, Pulmonic Diameter (Pulmonic Diam)
• SYS MICA (Systolic Mid Internal
Carotid Artery) LVI Ds) • Right Atrium
• DIAS MICA (Diastolic Mid Internal Left Ventricle Length (LVLd, LVLs) Right Atrium Diameter, Length (RAD
Carotid Artery) Left Ventricle Outflow Tract Diameter Ma)
• SYS PICA (Systolic Proximal Internal (LVOT Diam) Right Atrium Diameter, Width (RAD Mi)
Carotid Artery) Left Ventricle Posterior Wall Thickness Right Atrium Area (RAA)
• DIAS PICA (Diastolic Proximal (LVPWd, LVPWs) Right Atrium Volume, Single Plane,
Internal Carotid Artery)
Left Ventricle Length (LV Major) Method of Disk (RAAd)
• SYS DECA (Systolic Distal External
Carotid Artery) Left Ventricle Width (LV Minor) Right Atrium Volume, Systolic, Single
• DIAS DECA (Diastolic Distal External Left Ventricle Outflow Tract Area (LVOT) Plane, Method of Disk (RAAs)
Carotid Artery) Left Ventricle Area, Two Chamber/Four • Right Ventricle
• SYS PECA (Systolic Proximal External Chamber/Short Axis (LVA (d), LVA (s)) Right Ventricle Outflow Tract Area
Carotid Artery) Left Ventricle Endocardial Area, Width (RVOT Planimetry)
• DIAS PECA (Diastolic Proximal (LVA (d), LVA(s)) Left Pulmonary Artery Area (LPA Area)
External Carotid Artery)
Left Ventricle Epicardial Area, Length Right Pulmonary Artery Area (RPA Area)
• VERT (Systolic Vertebral Velocity)
• SUBCLAV (Systolic Subclavian (LVAepi (d), LVAepi (s)) Right Ventricle Internal Diameter
Velocity) Left Ventricle Mass Index (LVPWd, (RVIDd, RVIDs)
• Summary Reports LVPWs) Right Ventricle Diameter, Length (RVD
• Mean IMT Measurement Tools Ejection Fraction, Teichholz/Cube Ma)
(LVIDd, LVIDs) Right Ventricle Diameter, Width (RVD
Cardiac Left Ventricle Posterior Wall Fractional Mi)
Shortening (LVPWd, LVPWs) Right Ventricle Wall Thickness (RVAWd,
Measurements/Calculations Left Ventricle Stroke Index, RVAWs)
B-Mode Measurements Teichholz/Cube (LVIDd, LVIDs, and Right Ventricle Outflow Tract Diameter
• Aorta Body Surface Area) (RVOT Diam)
Aortic Root Diameter (Ao Root Diam) Left Ventricle Fractional Shortening Left Pulmonary Artery (LPA)
Aortic Arch Diameter (Ao Arch Diam) (LVIDd, LVIDs) Main Pulmonary Artery (MPA)
Ascending Aortic Diameter (Ao Asc) Left Ventricle Stroke Volume, Right Pulmonary Artery (RPA)
Descending Aortic Diameter (Ao Desc Teichholz/Cubic (LVIDd, LVIDs) • System
Diam) Left Ventricle Stroke Index, Single Plane, Interventricular Septum Thickness
Aorta Annulus Diameter (Ao Annulus Two Chamber, Method of Disk (LVI Dd, (IVSd, IVSs)
Diam) LVIDs, LVSd, LVSs) Inferior Vena Cava
Aorta Isthmus (Ao Isthmus) Left Ventricle Stroke Index, Single Plane, Pulmonary Artery Diameter (MPA)
Aorta *** (Ao st junct) Four Chamber, Method of Disk (LVI Dd, Systemic Vein Diameter (Systemic
• Aortic Valve LVIDs, LVSd, LVSs) Diam)
Aortic Valve Cusp Separation (AV Cusp) Left Ventricle Stroke Index, Bi-Plane, Patent Ductus Arterosis Diameter (PDA
Aortic Valve Area Planimetry (AVA Pl Bullet, Method of Disk (LVAd, LVAs) Diam)
ani met ry) Interventricular Septum (IVS) Pericard Effusion (PEs)
*** ( Trans AVA) Left Ventricle Internal Diameter (LVI D) Patent Foramen Ovale Diameter (PFO
• Left Atrium Left Ventricle Posterior Wall Thickness Diam)
Left Atrium Diameter (LA Diam) (LVPW) Ventricular Septal Defect Diameter
LA Length (LA Major) • Mitral Valve (VSD Diam)
LA W idth (LA Minor) Mitral Valve Annulus Diameter (MV Ann Interventricular Septum (IVS) Fractional
Left Atrium Diameter to AoRoot Diam) Shortening (IVSd, IVSs)
Diameter Ratio (LA/Ao Ratio) E-Point-to-Septum Separation (EPSS) • Tricuspid Valve
Left Atrium Area (LAA(d), LAA(s)) Mitral Valve Area by Pressure Half Time Tricuspid Valve Area (TV Panimetry)
Left Atrium Volume, Single Plane, (MVA By PHT) Tricuspid Valve Annulus Diameter (TV
Method of Disk (LAEDV A2C, LAESV Mitral Valve Area Planimetry (MVA Annulus Diam)
A2C ) (LAEDV A4C, LAESV A4C) Planimetry)
• Left Ventricle • Pulmonic Valve M-Mode Measurements

LOGIQ P5 Page 8 of 14
• Aorta • Tricuspid Valve Left Ventricle Outflow Tract Peak
Aortic Root Diameter (Ao Root Diam) QRS complex to end of envelope (Q-to- Pressure Gradient (VLOT Vmax)
• Aortic Valve TV close) Left Ventricle Outflow Tract Peak
Aortic Valve Diameter (AV Diam) Velocity (LVOT Vmax)
Aortic Valve Cusp Separation (AV Cusp) Doppler Mode Measurements Left Ventricle Outflow Tract Mean
Aortic Valve Ejection Time (LVET) • Aortic Valve Pressure Gradient (LVOT Trace)
• Left Atrium Aortic Insufficiency Mean Pressure Left Ventricle Outflow Tract Mean
Left Atrium Diameter to AoRoot Gradient (AR Trace) Velocity (LVOT Trace)
Diameter Ratio (LA/Ao Ratio) Aortic Insufficiency Peak Pressure Left Ventricle Outflow Tract Mean
Left Atrium Diameter (LA Diam) Gradient (AR Vmax) Square Root Velocity (LVOT Trace)
• Left Ventricle Aortic Insufficiency End Diastole Left Ventricle Outflow Tract Velocity
Left Ventricle Volume, Teichholz/Cubic Pressure Gradient (AR Trace) Time Integral (LVOT Trace)
(LVIDd, LVI Ds) Aortic Insufficiency Mean Velocity (AR Left Ventricle Ejection Time (LVET)
Left Ventricle Internal Diameter (LVIDd, Trace) Cardiac Output by Aortic Flow (AVA Pl
LVI Ds) Aortic Insufficiency Mean Square Root ani met ry, AV Trace)
Left Ventricle Posterior Wall Thickness Velocity (AR Trace) Stroke Volume Index by Aortic Flow
(LVPWd, LVPWs) Aortic Insufficiency Velocity Time (AVA Planimetry, AV Trace)
Left Ventricle Ejection Time (LVET) Integral (AR Trace) • Mitral Valve
Left Ventricle Pre-Ejection Period Aortic Valve Mean Velocity (AV Trace) Mitral Valve Regurgitant Flow
(LVPEP) Aortic Valve Mean Square Root Velocity Acceleration (MR Trace)
Interventricular Septum (IVS) (AV Trace) Mitral Valve Regurgitant Mean Velocity
Left Ventricle Internal Diameter (LVI D) Aortic Valve Velocity Time Integral (AV (MR Trace)
Left Ventricle Posterior Wall Thickness Trace) Mitral Regurgitant Mean Square Root
(LVPW) Aortic Valve Mean Pressure Gradient Velocity (MR Trace)
• Mitral Valve (AV Trace) Mitral Regurgitant Mean Pressure
E-Point-to-Septum Separation (EPSS) Aortic Valve Peak Pressure Gradient Gradient (MR Trace)
Mitral Valve Leaflet Separation (D-E (AR Vmax) Mitral Regurgitant Velocity Time
Excursion) Aortic Insufficiency Peak Velocity (AR Integral (MR Trace)
Mitral Valve Anterior Leaflet Excursion Vmax) Mitral Valve Mean Velocity (MR Trace)
(D-E Excursion) Aortic Insufficiency End-Diastolic Mitral Valve Mean Square Root Velocity
Mitral Valve D-E Slope (D-E Slope) Velocity (AR Trace) (MR Trace)
Mitral Valve E-F Slope (E-F Slope) Aortic Valve Peak Velocity (AV Vmax) Mitral Valve Velocity Time Integral (MR
• Pulmonic Valve Aortic Valve Peak Velocity at Point E Trace)
QRS complex to end of envelope (Q-to- (AV Vmax) Mitral Valve Mean Pressure Gradient
PV close) Aorta Proximal Coarctation (Coarc Pre- (MR Trace)
• Right Ventricle Duct) Mitral Regurgitant Peak Pressure
Right Ventricle Internal Diameter Aorta Distal Coarctation (Coarc Post- Gradient (MR Vmax)
(RVIDd, RVIDs) Duct) Mitral Valve Peak Pressure Gradient
Right Ventricle Wall Thickness (RVAWd, Aortic Valve Insufficiency Pressure Half (MR Vmax)
RVAWs) Time (AR PHT) Mitral Regurgitant Peak Velocity (MR
Right Ventricle Outflow Tract Diameter Aortic Valve Flow Acceleration (AV Vmax)
(RVOT Diam) Trace) Mitral Valve Peak Velocity (MR Vmax)
Right Ventricle Ejection Time (RVET) Aortic Valve Pressure Half Time (AV Mitral Valve Velocity Peak A (MV A
Right Ventricle Pre-Ejection Period Trace) Velocity)
(RVPEP) Aortic Valve Acceleration Time (AV Acc Mitral Valve Velocity Peak E (MV E
Velocity Circumferential Fiber Ti me) Velocity)
Shortening (Vcf) Aortic Valve Deceleration TIme (AV Mitral Valve Area according to PHT (MV
• System Trace) PHT)
Interventricular Septum Thickness Aortic Valve Ejection Time (AVET) Mitral Valve Flow Deceleration (MV
(IVSd, IVSs) Aortic Valve Acceleration to Ejection Trace)
Pericard Effusion (PE(d)) Time Ratio (AV Acc Time, AVET) Mitral Valve Pressure Half Time (PV
Interventricular Septum (IVS) Fractional Aortic Valve Area according to PHT PHT)
Shortening (IVSd, IVSs) • Left Ventricle Mitral Valve Flow Acceleration (MV

LOGIQ P5 Page 9 of 14
Trace) (PV Trace) IsoVolumetric Contraction Time (IVCT)
Mitral Valve E-Peak to A-Peak Ratio (A- Pulmonic Insufficiency Pressure Half Pulmonary Vein S/D Ratio (P Vein D, P
C and D-E) (MV E/ARatio) Time (PR PHT) Vein S)
Mitral Valve Acceleration Time (MV Acc Pulmonic Valve Flow Acceleration (PV Ventricular Septal Defect Peak
Time) Acc Time) Pressure Gradient (VSD Vmax)
Mitral Valve Deceleration Time (MV Dec Pulmonic Valve Acceleration Time (PV Pulmonic-to-Systemic Flow Ratio
Time) Acc Time) (Qp/Qs)
Mitral Valve Ejection Time ((MV Trace) Pulmonic Valve Ejection Time (PVET) • Tricuspid Valve
Mitral Valve A-Wave Duration (MV A Pulmonic Valve Pre-Ejection Period Tricuspid Regurgitant Peak Pressure
Dur) (PVPEP) Gradient (TR Vmax)
Mitral Valve Time to Peak (MV Trace) QRS complex to end of envelope (Q-to- Tricuspid Valve Peak Pressure Gradient
Mitral Valve Acceleration PV close) (TV Vmax)
Time/Deceleration Time Ratio Pulmonic Valve Acceleration to Ejection Tricuspid Regurgitant Peak Velocity (TR
(MVAcc/Dec Time) TIme Ratio (PV Acc Time, PVET) Vmax)
Stroke Volume Index by Mitral Flow Pulmonic Valve Pre-Ejection to Ejection Tricuspid Valve Peak Velocity (TV Vmax)
(MVA Planimetry, MVTrace) Time Ratio (PVPEP, PVET) Tricuspid Valve Velocity Peak A (TV A
Mitral Valve Area from Continuity • Right Ventricle Velocity)
Equation (MVAPlanimetry, LVOT Vmax, Right Ventricle Outflow Tract Peak Tricuspid Valve Velocity Peak E (TV E
MV Vmax) Pressure Gradient (RVOT Vmax) Velocity)
• Pulmonic Valve Right Ventricle Systolic Pressure (RVOT Tricuspid Regurgitant Mean Pressure
Pulmonic Insufficiency Peak Pressure Vmax) Gradient (TR Trace)
Gradient (PR Vmax) Right Ventricle Outflow Tract Peak Tricuspid Valve Mean Pressure
Pulmonic Insufficiency End-Diastolic Velocity (RVOT Vmax) Gradient (TV Trace)
Pressure Gradient (PRTrace) Right Ventricle Diastolic Pressure (RVOT Tricuspid Regurgitant Mean Velocity
Pulmonic Valve Peak Pressure Gradient Trace) (TR Trace)
(PV Vmax) Right Ventricle Outflow Tract Velocity Tricuspid Regurgitant Mean Square
Pulmonic End-Diastolic Pressure Time Integral (RVOTTrace) Root Velocity (TR Trace)
Gradient (PR Trace) Right Ventricle Ejection Time (RV Trace) Tricuspid Regurgitant Velocity Time
Pulmonic Insufficiency Peak Velocity Stroke Volume by Pulmonic Flow Integral (TR Trace)
(PR Vmax) (RVOTPlanimetry, RVOTTrace) Tricuspid Valve Mean Velocity (TV
Pulmonic Insufficiency End-Diastolic Right Ventricle Stroke Volume Index by Trace)
Velocity (Prend Vmax) Pulmonic Flow (RVOT Planimetry, RVOT Tricuspid Valve Mean Square Root
Pulmonic Valve Peak Velocity (PV Trace) Velocity (TV Trace)
Vmax) • System Tricuspid Valve Velocity Time Integral
Pulmonic End-Diastolic Velocity (PV Pulmonary Artery Peak Velocity (PV (TV Trace)
Trace) Vmax) Tricuspid Valve Time to Peak (TV
Pulmonary Artery Diastolic Pressure Pulmonary Vein Velocity Peak A Acc/Dec Time)
(PV Trace) (reverse) (P Vein A) Tricuspid Valve Ejection Time (TV
Pulmonic Insufficiency Mean Pressure Pulmonary Vein Peak Velocity (P Vein D, Acc/Dec Time)
Gradient (PR Trace) P Vein S) Tricuspid Valve A-Wave Duration (TV A
Pulmonic Valve Mean Pressure Systemic Vein Peak Velocity (PDA Dur)
Gradient (PV Trace) Diastolic, PDA Systolic) QRS complex to end of envelope (Q-to-
Pulmonic Insufficiency Mean Velocity Ventricular Septal Defect Peak Velocity TV close)
(PR Trace) (VSD Vmax) Tricuspid Valve Pressure Half Time (TV
Pulmonic Insufficiency Mean Square Atrial Septal Defect (ASD Diastolic, ASD PHT)
Root Velocity(PR Trace) Systolic) Stroke Volume by Tricuspid Flow (TV
Pulmonic Insufficiency Velocity Time Pulmonary Artery Velocity Time Planimetry, TV Trace)
Integral (PR Trace) Integral (PV Trace) Tricuspid Valve E-Peak to A-Peak Ratio
Pulmonic Valve Mean Velocity (PV Systemic Vein Velocity Time Integral (TV E/A Velocity)
Trace) (PDA Trace)
Pulmonic Valve Mean Square Root Pulmonary Vein A-Wave Duration (P Color Flow Mode Measurements
Velocity (PV Trace) Vein A Dur) • Aortic Valve
Pulmonic Valve Velocity Time Integral IsoVolumetric Relaxation Time (IVRT) - Proximal Isovelocity Surface Area:

LOGIQ P5 Page 10 of 14
Regurgitant Orifice Area (AR Radius) Left Ventricle Stroke Volume, Single - Applications: Abdomen, OB Gyn,
- Proximal Isovelocity Surface Area: Plane, Two Chamber/Four Chamber, Urology, Vascular
Radius of Aliased Point (AR Radius) Method of Disk(Simpson) (LVIDd, LVIDs, - Probe Band Width: 2.0 – 5.0 MHz
- Proximal Isovelocity Surface Area: LVAd, LVAs) - Number of Element: 128
Regurgitant Flow (AR Trace) Left Ventricle Volume, Two - Convex Radius: 38 mmR
- Proximal Isovelocity Surface Area: Chamber/Four Chamber, Area-Length - FOV (Max): 68°
Regurgitant Volume Flow (AR Trace) (LVAd, LVAs) - Physical Foot Print: 48 x 11 mm
Proximal Isovelocity Surface Area: Ejection Fraction, Bi-Plane, Method of - B-mode Imaging Frequency: 2.0, 3.0,
Aliased Velocity (AR Vmax) Disk (LVAd, LVAs, 2CH, 4CH) 4.0, 5.0 MHz
• Mitral Valve Left Ventricle Stroke Volume, Bi-Plane, - Harmonic Frequency: 4, 5, 5.2, 5.5
Proximal Isovelocity Surface Area: Method of Disk (LVAd, LVAs, 2CH, 4CH) MHz
Regurgitant Orifice Area (MR Radius) Left Ventricle Volume, Bi-Plane, Method - Doppler Frequency: 2.5, 3.3 MHz
Proximal Isovelocity Surface Area: of Disk (LVAd, LVAs, 2CH, 4CH) - Biopsy Guide Available: Single Angle,
Radius of Aliased Point (MR Radius) Left Ventricle Stroke Index, Single Plane, Reusable
Proximal Isovelocity Surface Area: Two Chamber/Four Chamber, Area-
Regurgitant Flow (MR Trace) Length (LVSd, LVSs, and BSA) • 3.5C Wide Band Convex Probe
Proximal Isovelocity Surface Area: Left Ventricle Volume, Single Plane, - Applications: Abdomen, OB Gyn,
Regurgitant Volume Flow (MR Trace) Two Chamber/Four Chamber, Method Urology, Vascular
Proximal Isovelocity Surface Area: of Disk (LVAd, LVAs) - Probe Band Width: 2.0 – 5.0 MHz
Aliased Velocity (MR Vmax) Left Ventricle Volume, Apical View, - Number of Element: 128
Long Axis, Method of Disk (LVAd, LVAs) - Convex Radius: 38 mmR
Combination Mode Measurements Stroke Volume by Aortic Flow (AVA - FOV (Max): 68°
• Aortic Valve Planimetry, AV Trace) - Physical Foot Print: 48 x 11 mm
- Aortic Valve Area (Ao Root Diam, • Mitral Valve - B-mode Imaging Frequency: 2.0, 3.0,
LVOT Vmax, AV Vmax) Stroke Volume by Mitral Flow (MVA 4.0, 5.0 MHz
- Aortic Valve Area by Continuity Planimetry, MV Trace) - Harmonic Frequency: 4, 5, 5.2, 5.5
Equation by Peak Velocity (Ao Root Cardiac Output by Mitral Flow (MVA MHz
Diam, LVOT Vmax, AV Vmax) Planimetry, MV Trace, HR) - Doppler Frequency: 2.5, 3.3 MHz
Stroke Volume by Aortic Flow (AVA Pl • Pulmonic Valve - Biopsy Guide Available: Single Angle,
ani met ry, AV Trace) Stroke Volume by Pulmonic Flow (PV Reusable
Cardiac Output by Aortic Flow (AVA Planimetry, PV Trace)
Planimetry, AV Trace, HR) Cardiac Output by Pulmonic Flow (PV • 4C Wide Band Convex Probe
Aortic Valve Area by Continuity Planimetry, PV Trace, HR) - Applications: Abdomen, OB Gyn,
Urology, Vascular
Equation VTI (Ao Root Diam, LVOT • Tricuspid Valve
- Probe Band Width : 1.4 – 5 MHz
Vmax, AV Trace) Cardiac Output by Tricuspid Flow (TV
- Number of Element: 128
• Left Ventricle Planimetry, TV Trace, HR)
- Convex Radius : 60 mmR
Cardiac Output, Teichholz/Cubic (LVIDd, - FOV (Max) : 58°
LVI Ds, HR) Report Designer - Physical Foot Print : 60 x 18 mm
Cardiac Output Two Chamber, Single • On-board reporting package - B-mode Imaging Frequency : 2.0,
automates report writing - 3.0, 4.0, 5.0 MHz
Plane, Area-Length/ Method of
• Formats various exam results into a - Harmonic Frequency : 4.0, 5.0, 5.2,
Disk(Simpson) (LVAd, LVAs, HR) report suitable for printing to a - 5.5 MHz
Cardiac Output Four Chamber, Single windows printer or reviewing on a - Doppler Frequency : 2.5, 3.3 MHz
Plane, Area-Length/ Method of standard PC - Biopsy Guide Available : Multi
Disk(Simpson) (LVAd, LVAs, HR) • Exam results include patient info, Angle, Reusable
Ejection Fraction Two Chamber, Single exam info, measurements, calculations,
Plane, Area-Length/ Method of images, comments and diagnosis • 5CS Convex Probe
• Standard templates provided - Applications: Abdomen, OB Gyn,
Disk(Simpson) (LVAd, LVAs)
Customizable templates Urology
Ejection Fraction Four Chamber, Single
- Probe Band Width : 2 – 6 MHz
Plane, Area-Length/ Method of - Number of Element : 128
Disk(Simpson) (LVAd, LVAs) - Convex Radius : 60 mmR
Left Ventricle Stroke Volume, Single Probes - FOV (Max) : 58°
Plane, Two Chamber/Four Chamber, - Physical Foot Print : 60 x 18 mm
Area-Length (LVAd, LVAs) • 3.5CS Thin Wide Band Convex Probe - B-mode Imaging Frequency : 2.0,
- 3.0, 4.0, 5.0 MHz

LOGIQ P5 Page 11 of 14
- Harmonic Frequency : 4.0, 5.0, 5.5, - 10.0, 12.0 MHz - Number of Element : 128
- 6.0 MHz - Harmonic Frequency : 10.0, 12.0, - Convex Radius : 9 mmR
- Doppler Frequency : 2.5, 3.3 MHz - 13.0 MHz - FOV (Max) : 170°
- Biopsy Guide Available : Multi - Doppler Frequency : 5.0, 6.7 MHz - Physical Foot Print : 15 x 10 mm
Angle, Reusable - Steered Angle : 0, +/- 5, 10, 15, 20° - B-mode Imaging Frequency : 6.0,
- Biopsy Guide Available : Multi - 8.0, 10.0 MHz
• 8L Wide Band Linear Probe - Angle, Reusable - Harmonic Frequency : 8.0, 10.0
- Applications : Vascular, Small MHz
Parts • 12L Wide Band Linear Probe - Doppler Frequency : 4.0, 5.0 MHz
- Probe Band Width : 4 – 11MHz - Applications: Small Parts, Vascular, - Biopsy Guide Available : Single
- Number of Element : 128 Neonatal, Pediatrics - Angle, Disposable and Reusable
- FOV (Max) : 38 mm
- Probe Band Width: 5 – 13.0 MHz
- Physical Foot Print : 38 x 10 mm • 8C Wide Band Microconvex Probe
- B-mode Imaging Frequency : 6.0, - Number of Element: 192 - Applications : Neonatal, Pediatrics
- 8.0, 10.0 MHz - FOV (Max): 39 mm - Probe Band Width : 4 11 MHz
- Harmonic Frequency : 8.0, 10.0, - Physical Foot Print: 45 x 10 mm - Number of Element : 128
- 12.0 MHz - B-mode Imaging Frequency: 7.0, 10.0, - Convex Radius : 11 mmR
- Doppler Frequency : 5.0, 6.7 MHz 12.0 MHz - FOV (Max) : 133°
- Steered Angle : 0, +/- 5, 10, 15, 20° - Harmonic Frequency: 10.0, 12.0 MHz - Physical Foot Print : 26 x 10 mm
- Biopsy Guide Available : Multi - B-mode Imaging Frequency : 6.0,
- Doppler Frequency: 5.0, 6.7 MHz
Angle, Reusable - 8.0, 10.0 MHz
- Steered Angle: +/- 10°, 20° - Harmonic Frequency : 8.0, 10.0
• 9L Wide Band Linear Probe Biopsy Guide Available: Single Angle, MHz
- Applications: Vascular, Small Parts Reusable - Doppler Frequency : 4.0, 5.0 MHz
- Probe Band Width : 3 – 10 MHz - Biopsy Guide Available : None
- Number of Element : 192 • 3CRF Wide Band Microconvex Probe
- FOV (Max) : 44 mm - Applications: Abdomen, Urology, • 3S Wide Band Phased Array Sector
- Physical Foot Print : 44 x 6 mm Vascular Probe
- B-mode Imaging Frequency : 5.0, - Probe Band Width : 2.0 – 4 MHz - Applications : Cardiac, Trancranial,
- 7.0, 9.0 MHz - Number of Element: 128 Abdomen
- Harmonic Frequency : 8.0, 10.0 - Convex Radius : 20 mmR - Probe Band Width : 1.5 – 3.5 MHz
- MHz - FOV (Max) : 80° - Number of Element : 64
- Doppler Frequency : 4.0, 5.0 MHz - Physical Foot Print : 28 x 16 mm - FOV (Max) : 90°
- Steered Angle : 0, +/- 5, 10, 15, 20° - B-mode Imaging Frequency : 2.0, - Physical Foot Print : 19 x 16 mm
- Biopsy Guide Available : Multi - 3.0, 3.5, 4.0 MHz - B-mode Imaging Frequency : 2.0,
- Angle, Reusable - Harmonic Frequency : 3.6, 3.8, 4.0, - 2.5, 3.0 MHz
- 4.2MHz - Harmonic Frequency : 2.8, 3.0, 3.2,
- Doppler Frequency : 2.5, 3.3 MHz - 3.6 MHz
• 10L Wide Band Linear Probe
- Biopsy Guide Available : Single - Doppler Frequency : 1.7, 2.0, 2.2
- Applications: Vascular, Small Parts, Angle, Reusable
Neonatal, Pediatrics - MHz
- CW Doppler Frequency : 2.0 MHz
- Probe Band Width: 4 – 11 MHz • E8C Wide Band Microconvex Probe - Biopsy Guide Available : Multi
- Number of Element: 192 - Applications : OB Gyn, Urology, - Angle, Reusable
- FOV (Max): 39 mm Endocavity
- Physical Foot Print: 39 x 10 mm - Probe Band Width : 4 – 11 MHz • 5S Wide Band Phased Array Sector
- B-mode Imaging Frequency: 6.0, 8.0, - Number of Element : 128 Probe
- Convex Radius : 11 mmR - Applications : Cardiac, Trancranial,
10.0 MHz
- FOV (Max) : 133° Abdomen
- Doppler Frequency: 5.0, 6.7 MHz - Physical Foot Print : 26 x 10 mm - Probe Band Width : 2 – 5 MHz
- Steered Angle: +/- 10°, 20° - B-mode Imaging Frequency : 6.0, - Number of Element : 96
- Biopsy Guide Available: Multi Angle, - 8.0, 10.0 MHz - FOV (Max) : 90°
Reusable - Harmonic Frequency : 8.0, 10.0 - Physical Foot Print : 19 x 11 mm
- MHz - B-mode Imaging Frequency : 3.0 ,
• 11L Wide Band Linear Probe - Doppler Frequency : 4.0, 5.0 MHz - 4.0, 5.0 MHz
- Applications : Small Parts, - Biopsy Guide Available : Single - Harmonic Frequency : 4.0, 5.0 MHz
Vascular, Neonatal, Pediatrics Angle, Disposable and Reusable - Doppler Frequency : 2.5, 3.3 MHz
- Probe Band Width : 5 – 13 MHz - CW Doppler Frequency : 2.5 MHz
- Number of Element : 192 • E8CS Wide Band Microconvex Probe Biopsy Guide Available: Multi Angle,
- FOV (Max) : 38.4 mm - Applications : OB Gyn, Urology, Reusable
- Physical Foot Print : 38 x 10mm Endocavity
- B-mode Imaging Frequency : 7.0, - Probe Band Width : 4 – 11 MHz

LOGIQ P5 Page 12 of 14
• 7S Wide Band Phased Array Sector - 8.0, 10.0 MHz ERB Convex: 5 - 9MHz
Probe - Harmonic Frequency : 10.0, - Number of Element: 128
- Applications: Cardiac, Pediatrics, - 12.0MHz - FOV (Max) :
Abdomen - Doppler Frequency : 5.0, 6.7 MHz ERB Linear: 51mm
- Probe Band Width : 3 – 8 MHz - Steered Angle : +/- 5, 10, 15, 20° ERB Convex: 123°
- Number of Element : 96 - Biopsy Guide Available : None - Physical Foot Print:
- FOV (Max) : 90° ERB Linear: 51 x 5 mm
- Physical Foot Print : 14 x 7 mm • t739 Intraoperative Wide Band ERB Convex: 17 x 5.5 mm
- B-mode Imaging Frequency : 5.0, Linear Probe - B-mode Imaging Frequency: 6.0, 8.0,
- 6.0, 7.0 MHz - Applications : Intraoperative, Small 10.0 MHz
- Harmonic Frequency : 6.0, 7.0, 8.0, Parts, Vascular, Pediatrics - Harmonic Frequency: 8.0, 10.0 MHz
- 8.5 MHz - Probe Band Width : 4 -10 MHz - Doppler Frequency: 5.0, 6.7 MHz
- Doppler Frequency : 4.0, 5.0 MHz - Number of Element: 192 - Biopsy Guide Available: Multi
- CW Doppler Frequency : 4.0 MHz - FOV (Max) : 39 mm Angle, Grid Reusable
- Biopsy Guide Available : None - Physical Foot Print : 39 x 10 mm
- B-mode Imaging Frequency : 6.0, • 4D3C-L Convex Volume Probe
• 3Sp Wide Band Phased Array Sector - 8.0, 10.0 MHz - Applications : Abdomen, OB Gyn
Probe - Harmonic Frequency : 8.0, 10.0, - Probe Band Width : 2 – 5 MHz
- Applications : Cardiac, Trancranial, - 12.0 MHz - Number of Element: 192
Abdomen - Doppler Frequency : 5.0, 6.7 MHz - Convex Radius : 39.1 mmR
- Probe Band Width : 1.5 – 5MHz - Steered Angle : +/- 5, 10, 15, 20° - Volume Sweep Radius: 19.8 mmR
- Number of Element : 64 - Biopsy Guide Available : Multi - FOV: 87° Volume 85° x 80°
- FOV (Max) : 90° - Angle, Reusable - Physical Foot Print : 60 x 13 mm
- Physical Foot Print : 16 x 14 mm - B-mode Imaging Frequency : 3.0,
- B-mode Imaging Frequency : 2.0, • i739 Intraoperative Wide Band - 4.0, 5.0 MHz
- 3.0, 4.0, 5.0 MHz Linear Probe - Harmonic Frequency : 4.0, 4.5, 4.8,
- Harmonic Frequency : 3.0, 3.5, 4.0, - Applications : Intraoperative, Small - .0 MHz
- 5.0, 5.5 MHz - Parts, Vascular, Pediatrics - Doppler Frequency : 2.5, 3.3 MHz
- Doppler Frequency : 1.8, 2.0, 2.5, - Probe Band Width : 4 – 10 MHz - Biopsy Guide Available : Single
- 3.3, 4.0 MHz - Number of Element: 192 Angle, Reusable (stainless steel,
- CW Doppler Frequency : 2.0 MHz - FOV (Max) : 39 mm plastic)
Biopsy Guide Available: Multi Angle, - Physical Foot Print : 39 x 10 mm
Reusable - B-mode Imaging Frequency : 6.0, • 4D8C Micro Convex Volume Probe
- 8.0, 10.0 MHz - Applications : Neonatal, Pediatrics
• 5Sp Wide Band Phased Array Sector - Harmonic Frequency : 8.0, 10.0, - Probe Band Width : 4 – 11 MHz
Probe - 12.0 MHz - Number of Element: 192
- Applications : Cardiac, Trancranial, - Doppler Frequency : 5.0, 6.7 MHz - Convex Radius : 14.0 mmR
Abdomen - Steered Angle : +/- 5, 10, 15, 20° - Volume Sweep Radius: 80 mm
Probe Band Width : 2.0 – 8.0 MHz Biopsy Guide Available : None - FOV: 120° Volume 37.4 mm x 29°
- Number of Element : 64 - Physical Foot Print : 30 x 50 mm
- FOV (Max) : 90° • BE9CS Wide Band Biplane - B-mode Imaging Frequency : 6.0,
- Physical Foot Print : 10 x 10 mm Microconvex Probe - 8.0, 10.0 MHz
- B-mode Imaging Frequency : 4.0, - Applications: Urology, Endocavity - Harmonic Frequency : 8.0, 10.0,
- 5.0, 6.7, 8.0 MHz - Probe Band Width : 4 – 11MHz - 1.0 MHz
- Harmonic Frequency : 5.0, 6.0, 8.0, - Number of Element : 96 x 2 - Doppler Frequency : 4.0, 5.0 MHz
- 10.0 MHz - Convex Radius : 9 mmR - Biopsy Guide Available : Single
- Doppler Frequency : 2.7, 3.0, 3.3 - FOV (Max) : 127° Angle Reusable(stainless steel, plastic)
- 4.0, 5.0 MHz - Physical Foot Print : 20 x 10 mm
- CW Doppler Frequency : 2.5 MHz - B-mode Imaging Frequency : 6.0, • 4DE7C Convex Volume Probe
Biopsy Guide Available: Multi Angle, - 8.0, 10.0 MHz - Applications : OB Gyn, Urology
Reusable - Harmonic Frequency : 8.0, 10.0 - Probe Band Width : 4 – 11 MHz
- MHz - Number of Element: 192
• i12L Intraoperative Wide Band - Doppler Frequency : 4.0, 5.0 MHz - Convex Radius: 10.1 mmR
Linear Probe - Biopsy Guide Available : Single - Volume Sweep Radius: 11.6 mmR
- Applications : Intraoperative, Small Angle Reusable (stainless steel), - FOV: 133° Volume 146° x 90°
- Parts, Vascular, Pediatrics Disposable - Physical Foot Print : 27 x 6 mm
- Probe Band Width : 4 – 12 MHz - B-mode Imaging Frequency : 6.0,
- Number of Element : 96 • ERB Wide Band Biplane Probe - 8.0, 10.0 MHz
- FOV (Max) : 25 mm - Applications: Urology - Harmonic Frequency : 8.0, 10.0,
- Physical Foot Print : 29 x 10 mm - Probe Band Width: - 11.0 MHz
- B-mode Imaging Frequency : 6.0, ERB Linear5 – 10 MHz - Doppler Frequency : 4.0, 5.0 MHz

LOGIQ P5 Page 13 of 14
- Biopsy Guide Available : Single • CE Marked to Council Directive
Angle, Reusable (stainless steel) 93/42/EEC on Medical Devices GE Ultraschall Deutschland GmbH & Co KG
• Conforms to the following standards Beethovenstr. 239, D-42655 Solingen
for safety: Tel.: (+49) 212-2802-0
• P2D Non-imaging Single CW
Fax: (+49) 212-2802-28
Doppler Pencil Probe -IEC/EN 60601-1 Medical Electrical
- Applications : Cardiac equipment, General requirement for Internet : www.gehealthcare.com
- Frequency: 2.0 MHz Safety
-IEC/EN 60601-1-1 Safety
• P6D Non-imaging Single CW GE, GE Monogram and LOGIQ®, CrossXBeam ,
requirements for Medical Electrical
Doppler Pencil Probe TruScan , LOGIQView and Inte are trademarks
Systems
- Applications : Cardiac, Vascular, of General Electric Company.
Pediatric -IEC/EN 60601-1-2 Electromagnetic
- Frequency: 5.0 MHz compatibility
GE Medical Systems Ultrasound & Primary
-IEC/EN 60601-1-4 Programmable Care Diagnostics, LLC a General Electric
• UG7C Gastro Probe – Europe Only medical systems company doing business as GE Healthcare
- Applications Transesophageal, -IEC/EN 60601-2-37 Particular
Stomach requirements for the safety of
- Probe Band Width : 4.5 – 10MHz
ultrasonic medical diagnostic and
- Number of Element: 128
- Convex Radius: 8.5 mmR monitoring equipment
- FOV (Max) : 125° -IEC 61157 Declaration of acoustic
- Physical Foot Print : 19 x 5 mm output
- B-mode Imaging Frequency : 6.0, -ISO 10993 Biological evaluation of
- 8.0, 10.0 MHz medical devices
- Harmonic Frequency : 8.0, 10.0 ·NEMA UD3 Acoustic output display (MI,
- MHz
TIS, TIB, TIC)
- Doppler Frequency : 5.0, 6.7 MHz
- Biopsy Guide Available: None
* available only in Europe
© 2008 General Electric Company - All rights reserved.

Inputs and Outputs


• Video In
- S-Video
• Video Out
- S-Video Not all features or specifications
• Audio Stereo In described in this document may be
• VGA out available in all probes and/or modes.
• Connectors
- Footswitch General Electric Company reserves the
- USB (6) right to make changes in specifications
- Ethernet and features shown herein, or
- Power for Peripherals discontinue the product at any time
without notice or obligation. Contact GE
Representative for the most current
information.

Safety Conformance
The LOGIQ P5 is: GE Healthcare. - America: 888-202-5528 P.O
Box 414, Milwaukee , Wisconsin 53201 USA
• Listed to UL 60601-1 by a Nationally
GE Healthcare , GE Asia Technology Park
Recognized Test Lab
3rd Floor, Building 1,1 Hua Tuo Road ,
• Certified to CAN/CSA C22.2 601.1 by an Shanghai – 201203
SCC accredited Test Lab Tel : +86 21 38774000

LOGIQ P5 Page 14 of 14