Features
● Temperature detection of two-dimensional area: 8 × 8 (64 pixels)
● Digital output (capability of temperature value output)
● Compact SMD package (adaptively to reflow mounting)
● RoHS compliant
Typical applications
● High function home appliances (microwaves and air-conditioners)
● Energy saving at office (air-conditioning/lighting control)
● Digital signage
● Automatic doors/elevators
Ordering information
AMG 8 8
Types
Tape and reel package : 1,000 pcs.
Product name Number of pixel Operating voltage Amplification factor Part number
High performance type
AMG8833
High gain
3.3 V.DC
Infrared array sensor High performance type
AMG8834
Grid-EYE 64 Low gain
High performance (Vertical 8 × Horizontal 8 Matrix) High performance type
type AMG8853
High gain
5.0 V.DC
High performance type
AMG8854
Low gain
Rating
Performance
Item
High gain Low gain
Applied voltage 3.3 V.DC±0.3 V.DC or 5.0 V.DC±0.5 V.DC
Temperature range of measuring object 0 °C to 80 °C +32 °F to +176 °F −20 °C to 100 °C –4 °F to +212 °F
Operating temperature range 0 °C to 80 °C +32 °F to +176 °F −20 °C to 80 °C –4 °F to +176 °F
Storage temperature range −20 °C to 80 °C –4 °F to +176 °F −20 °C to 80 °C –4 °F to +176 °F
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 02 Apr. 2017
Infrared Array Sensor Grid-EYE (AMG88)
Characteristics
Performance
Item High performance type High performance type
High gain Low gain
Temperature accuracy Typical ±2.5 °C ±4.5 °F Typical ±3.0 °C ±5.4 °F
Human detection distance ✽1 7 m or less (reference value) 22.966 ft
Typ. 0.05 °C 32.900 °F 1 Hz
NETD ✽2
Typ. 0.16 °C 32.288 °F 10 Hz
Viewing angle Typical 60 °
Optical axis gap Within Typical ±5.6 °
Typical 4.5 mA (normal mode)
Current consumption Typical 0.2 mA (sleep mode)
Typical 0.8 mA (stand-by mode)
Typical 50 ms (Time to enable communication after setup)
Setup time
Typical 15 s (Time to stabilize output after setup)
Note: ✽1 To have more than 4 °C 7.2 °F of temperature difference from background
Detection object size: 700 × 250 mm 27.559 × 9.843 inch (Assumable human body size)
✽2 It is calculated from 4 pixels of centers.
Performance
Item Performance
Number of pixel 64 (Vertical 8 × Horizontal 8 Matrix)
External interface I2C (fast mode)
Frame rate Typical 10 frames/sec or 1 frame/sec
Normal
Operating mode ✽1 Sleep
Stand-by (10 sec or 60 sec intermittence)
Output mode Temperature output
Calculate mode No moving average or Twice moving average
Temperature output resolution 0.25 °C 32.45 °F
Number of sensor address 2 (I2C slave address)
Thermistor output temperature range −20 °C to 80 °C –4 °F to +176 °F
Thermistor output resolution 0.0625 °C 32.1125 °F
Note: ✽1 Normal Mode : normal operation mode; Sleep Mode: detection is off (output and data reading not possible); Standby Mode: 1 frame measuring
intermittently every 10 or 60 sec.
Internal circuit
3.3 V.DC or 5 V.DC Infrared array sensor
Sensor chip
SDA
VDD 2
ROM
9
SCL
I2C I/F 3
Selector
Control
Capacitor AD_SELECT
10 μF 5
Gain
GND amp ADC INT
6 4
Thermistor
GND
✽ INT terminal 4 normally has same voltage as VDD. When interrupting, same as GND (0V)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 02 Apr. 2017
Infrared Array Sensor Grid-EYE (AMG88)
64 63 62 61 60 59 58 57
56 55 54 53 52 51 50 49
48 47 46 45 44 43 42 41
40 39 38 37 36 35 34 33
16 15 14 13 12 11 10 9
8 7 6 5 4 3 2 1
Optical properties
(1) Each pixel’s viewing central angle (2) Each pixel’s viewing angle (half angle)
Sensor’s optical center (the origin of graph below) Central 4 pixels (Pixel No. 28, 29, 36, 37) viewing
gap: within ±5.6 ° (Typical) (Both horizontal and angle (half angle): horizontal direction 7.7 ° (Typical)
vertical directions) vertical direction 8 ° (Typical)
40
20 20
Each pixel’s horizontall viewing angle (°)
15 15
20
10 10
10
5 5
0
−40 −30 −20 −10 0 10 20 30 40
0 0
1 5 9 13 17 21 25 29 33 37 41 45 49 53 57 61 1 5 9 13 17 21 25 29 33 37 41 45 49 53 57 61
−10
Pixel number Pixel number
−20
−30
−40
Horizontal viewing central angle (° )
Dimensions
2 SDA 9 VDD
(0.030)
(0.75)
P 3 SCL J AVDD-PC
0.209
0.315
0.138
0.343
8.0
5.3
3.5
8.7
51
4 INT K NC
0.142
3.6
5 AD_SELECT L DVDD-PC
1 7
Part No.
11.6
0.457
6 GND M VPP 10-0.7
✽Four corners
4-0.8
(AMG88 is omitted) Lot No.
7 NC N NC 10-0.028 4-0.031
P1.27±0.05×4=5.08
8.9
0.350 Note : Leave terminal “NC (No.1,7,8,K and N)” P0.050±0.002×4=0.200
unconnected.
0.059
M the same.
14-0.5
1 14-0.0207
0.118
0.307 3.0
7.8
N 8
P1.27×4
13-0.079
13-2.0
P0.050×4
10.9 General tolerance : ±0.2 ±0.08 unit : mm inch
0.429
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 02 Apr. 2017
Infrared Array Sensor Grid-EYE (AMG88)
External circuit
(1) In case of setting I2C slave address of the sensor 1101000 (2) In case of setting I2C slave address of the sensor 1101001
✽ Connect terminal 5 (AD_SELECT) to GND. ✽ Connect terminal 5 (AD_SELECT) to VDD.
VDD VDD
10 kΩ±5%
10 kΩ±5%
10 kΩ±5%
10 kΩ±5%
10 kΩ±5%
10 kΩ±5%
10 kΩ±5%
2SDA MVPP 2SDA MVPP
To microcomputer etc. To microcomputer etc.
3SCL LDVDD-PC 3SCL LDVDD-PC
To microcomputer etc. To microcomputer etc.
4INT 4INT
To microcomputer etc. To microcomputer etc.
5AD_SELECT JAVDD-PC 5AD_SELECT JAVDD-PC
6GND 9VDD 6GND 9VDD
1 μF±10%
1 μF±10%
20 Ω±5%
1.5 μF±10% 1.5 μF±10%
20 Ω±5%
10 μF±20% 10 μF±20%
GND GND
This circuit is an example to drive infrared array sensor “Grid-EYE”, so that we will not take any responsibility of loss
which is due to this circuit.
3.150±.039 dia.
80±0.1 dia.
0.014±0.020
14.961±0.079 dia.
+0.1 dia
.
380.0±2.0 dia.
. Top cover tape
1.5 9+00.004 dia
0
0.05
Embossed carrier tape
Direction of picking
0.157±0.004
0.630±0.004
4.0±0.1
16.0±0.1
dia.
0 dia.
0.059 +0.004
13±0.2 dia.
0
1.5 +0.1
0.496±0.004
0.512±0.08 dia.
12.6±0.1
0.079±0.004
2.0±0.1
9.0±0.1 4.7±0.1
0.354±0.004 0.185±0.004 unit : mm inch
Notes
■ Precaution for fundamental structure of sensor 4) Vibrations and shocks may damage the sensor, and
Infrared Array Sensor is a thermopile type infrared cause malfunction and performance deterioration.
sensor which detects the amount of infrared rays. Below If loads and shocks are applied on the lense,
conditions generally degrade the temperature accuracy. the damaged sensor may cause malfunction and
Carefully check the performance and stability under performance deterioration.
actual use conditions, and perform temperature 5) The product is not water/splash-proof. Perform
corrections when necessary. water/dust-proofing and dew condensation/
• When heating elements exist near the mounting freezing countermeasures in accordance with use
position of the sensor. environment. When dew condensation occurs,
• When the sensor is exposed to cold or hot air. responsiveness of heat source detection may delay
• When the temperature of the sensor body rapidly for several seconds.
changes. 6) Avoid use and storage in the corrosive gas (organic
• When substances (e.g., glasses, acrylics or steams), solvent, sulfurous acid and hydrogen sulfide gases)
which hardly transmit a far infrared ray, exist to avoid malfunction and performance deterioration.
between the sensor and the detected object. 7) Use surge absorbers as applying the external surge
• When substances (e.g., foreign substances or voltage may damage the internal circuit.
water), which hardly transmit a far infrared ray, 8) Malfunction may occur near electric noises from
adhere to the lense of the sensor. static electricity, lightning, broadcast or amateur radio
stations and mobile phones.
■ Use environment 9) The sensor can continuously operate within the
range of using ambient temperature (using ambient
1) Temperature: See the specifications humidity). However, ensure that humidity is within the
2) Humidity: Between 15% and 85% R.H. (Avoid range described in the following page as humidity
freezing and dew condensation) varies according to temperature. Avoid the continuous
3) Atmospheric pressure: Between 86 and 106 kPa operation near the operational limit. The temperature
range does not guarantee the durability.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 02 Apr. 2017
Infrared Array Sensor Grid-EYE (AMG88)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 02 Apr. 2017
Infrared Array Sensor Grid-EYE (AMG88)
■ Special notes
We exert maximum efforts for quality control of the
product, however :
1) To p r e v e n t o c c u r r e n c e o f u n e x p e c t e d
circumstances, please infor m us of the
specifications of your product, customers, use
conditions and details of the attachment position.
2) Have sufficient margin values of driving/
performance guarantee described in the
specifications and apply safety measures with
double circuits, if serious effects on human
lives or property are predicted due to a quality
failure of the product. Those countermeasures
are also for the product liability.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 02 Apr. 2017