Vous êtes sur la page 1sur 2

METHOD STATEMENT FOR TOILET / SUNKEN WATER PROOFING

Sl. No. Procedure


1 Clean the floor surface properly
2 Check the Sleeve position as per drawing
3 Apply the SBR bonding agent in concrete surface
Fix the plumbing pipe ( 110mm dia ) as per drawing and maintain
4
minimum 10mm gap between concrete & pipe
Grout the Core area by using of Master flow 718 Non shrink
5
cementious grouting material from BASF
Mix Proportion Add water 4 litres for 25kg of powder and mixing
to be done by using of paddle or hand mix up to lump free
6
appearance. Prepared Material should be consumed within
30minutes .

Prepare the coving in wall & slab corner joints 50x50mm by using
7 of Master Emaco SBR Bonding agent in the ratio of 1:1:5 (1
Part SBR bonding agent 1 part Cement & 15 part mortar

Conduct the Water pond test 48 Hours for observing the lekages
8
in slab
If any leakage observed Do nozzel grouting by using of Master
9 Flow 150 material in the interval of 600mm c/c in depth of 75mm
& 15 dia hole.
Finishing the concrete surface -Plastering 12mm thick with
cement mortor 1:4 admixed with waterproofing chemical
10
( MasterPel 777) material. Add 150ml masterpel 777 for 50kg of
cement
Before applying of brush bond coat floor surface area to be clean
11
and free from loose particles & dead mortar
Apply first coat of brush bond coat by using of Master seal 550
(Acrylic cementious flexible waterproofing coating )
Mix Proportion : 15kg of
12
powder & 5kg of liquid Mixing to be done
by using of paddle or hand mix up to lump free appearance .

Apply second coat of brush bond coat by using of Master seal


550 (Acrylic cementious flexible waterproofing coating )
Mix Proportion :
13
15kg of powder & 5kg of liquid Mixing to be
done by using of paddle or hand mix up to lump free
appearance .
Protect the waterproofing brush bond coated area by plastering
12mmthick with cement mortor 1:4 admixed with waterproofing
14
chemical ( MasterPel 777) material. Add 150ml masterpel 777
for 50kg of cement
Conduct the Water pond test 48 Hours for observing the lekages
15
in slab
Provide Safety barication for avoiding manpower movement in
16
waterprooing completed area
NKEN WATER PROOFING
Option 2

Cico No:1

Cico: Tapecrete P151 - 2mm Thk

Cico: Tapecrete P151 - 2mm Thk

Cico No:1

Vous aimerez peut-être aussi