Vous êtes sur la page 1sur 2

FOR 1%

MH. MH. GL START GL STOP IL START IL STOP PIPE SIZE SLOPE LENGTH DEPTH TO INVERT DEPTH TO INVERT PIPE COVER PIPE COVER MH START MH STOP MH TYPE MH TYPE
START STOP (m) (m) (m) (m) (mm) (m) START (m) STOP (m) START (m) STOP (m) SIZE (m DIA.) SIZE (m DIA.)
SMH-4 SMH-3 24.400 24.400 23.000 22.350 200 1% 65 1.40 2.05 1.20 1.85 1.40 1.65 SPECIAL A
SMH-3 SMH-2 24.400 24.300 22.350 21.700 200 1% 65 2.05 2.60 1.85 2.40 1.65 1.65 A A
SMH-2 SMH-1 24.300 24.300 21.700 20.890 200 1% 81 2.60 3.41 2.40 3.21 1.65 2.10 A B

FOR 0.2% (NOT ACCEPTABLE)


MH. MH. GL START GL STOP IL START IL STOP PIPE SIZE SLOPE LENGTH DEPTH TO INVERT DEPTH TO INVERT PIPE COVER PIPE COVER MH START MH STOP MH TYPE MH TYPE
START STOP (m) (m) (m) (m) (mm) (m) START (m) STOP (m) START (m) STOP (m) SIZE (m DIA.) SIZE (m DIA.)
SMH-4 SMH-3 24.400 24.400 23.000 22.870 200 0.20% 65 1.40 1.53 1.20 1.33 1.40 1.40 SPECIAL A
SMH-3 SMH-2 24.400 24.300 22.870 22.740 200 0.20% 65 1.53 1.56 1.33 1.36 1.40 1.65 A A
SMH-2 SMH-1 24.300 24.300 22.740 22.578 200 0.20% 81 1.56 1.72 1.36 1.52 1.65 1.65 A A

FOR 0.4%
MH. MH. GL START GL STOP IL START IL STOP PIPE SIZE SLOPE LENGTH DEPTH TO INVERT DEPTH TO INVERT PIPE COVER PIPE COVER MH START MH STOP MH TYPE MH TYPE
START STOP (m) (m) (m) (m) (mm) (m) START (m) STOP (m) START (m) STOP (m) SIZE (m DIA.) SIZE (m DIA.)
SMH-4 SMH-3 24.400 24.400 23.000 22.740 200 0.40% 65 1.40 1.66 1.20 1.46 1.40 1.65 SPECIAL A
SMH-3 SMH-2 24.400 24.300 22.740 22.480 200 0.40% 65 1.66 1.82 1.46 1.62 1.65 1.65 A A
SMH-2 SMH-1 24.300 24.300 22.480 22.156 200 0.40% 81 1.82 2.14 1.62 1.94 1.65 1.65 A A

FOR 0.5% (Min for Ø200)


MH. MH. GL START GL STOP IL START IL STOP PIPE SIZE SLOPE LENGTH DEPTH TO INVERT DEPTH TO INVERT PIPE COVER PIPE COVER MH START MH STOP MH TYPE MH TYPE
START STOP (m) (m) (m) (m) (mm) (m) START (m) STOP (m) START (m) STOP (m) SIZE (m DIA.) SIZE (m DIA.)
SMH-4 SMH-3 24.400 24.400 23.000 22.675 200 0.50% 65 1.40 1.73 1.20 1.53 1.40 1.65 SPECIAL A
SMH-3 SMH-2 24.400 24.300 22.675 22.350 200 0.50% 65 1.73 1.95 1.53 1.75 1.65 1.65 A A
SMH-2 SMH-1 24.300 24.300 22.350 21.945 200 0.50% 81 1.95 2.36 1.75 2.16 1.65 1.65 A A

FOR 0.6%
MH. MH. GL START GL STOP IL START IL STOP PIPE SIZE SLOPE LENGTH DEPTH TO INVERT DEPTH TO INVERT PIPE COVER PIPE COVER MH START MH STOP MH TYPE MH TYPE
START STOP (m) (m) (m) (m) (mm) (m) START (m) STOP (m) START (m) STOP (m) SIZE (m DIA.) SIZE (m DIA.)
SMH-4 SMH-3 24.400 24.400 23.000 22.610 200 0.60% 65 1.40 1.79 1.20 1.59 1.40 1.65 SPECIAL A
SMH-3 SMH-2 24.400 24.300 22.610 22.220 200 0.60% 65 1.79 2.08 1.59 1.88 1.65 1.65 A A
SMH-2 SMH-1 24.300 24.300 22.220 21.734 200 0.60% 81 2.08 2.57 1.88 2.37 1.65 1.65 A A
FOR 1%
MH. MH. GL START GL STOP IL START IL STOP PIPE SIZE SLOPE LENGTH DEPTH TO INVERT DEPTH TO INVERT PIPE COVER PIPE COVER MH START MH STOP MH TYPE MH TYPE
START STOP (m) (m) (m) (m) (mm) (m) START (m) STOP (m) START (m) STOP (m) SIZE (m DIA.) SIZE (m DIA.)
SMH-4 SMH-3 24.70 24.55 23.30 22.33 200 1% 97 1.40 2.22 1.20 2.02 1.40 1.65 SPECIAL A
SMH-3 SMH-2 24.55 24.45 22.33 21.68 200 1% 65 2.22 2.77 2.02 2.57 1.65 1.65 A A
SMH-2 SMH-1 24.45 24.30 21.68 20.87 200 1% 81 2.77 3.43 2.57 3.23 1.65 2.10 A B

FOR 0.2% (NOT ACCEPTABLE)


MH. MH. GL START GL STOP IL START IL STOP PIPE SIZE SLOPE LENGTH DEPTH TO INVERT DEPTH TO INVERT PIPE COVER PIPE COVER MH START MH STOP MH TYPE MH TYPE
START STOP (m) (m) (m) (m) (mm) (m) START (m) STOP (m) START (m) STOP (m) SIZE (m DIA.) SIZE (m DIA.)
SMH-4 SMH-3 24.70 24.55 23.30 23.11 200 0.20% 97 1.40 1.44 1.20 1.24 1.40 1.40 SPECIAL A
SMH-3 SMH-2 24.55 24.45 23.11 22.98 200 0.20% 65 1.44 1.47 1.24 1.27 1.40 1.65 A A
SMH-2 SMH-1 24.45 24.30 22.98 22.81 200 0.20% 81 1.47 1.49 1.27 1.29 1.65 1.65 A A

FOR 0.4%
MH. MH. GL START GL STOP IL START IL STOP PIPE SIZE SLOPE LENGTH DEPTH TO INVERT DEPTH TO INVERT PIPE COVER PIPE COVER MH START MH STOP MH TYPE MH TYPE
START STOP (m) (m) (m) (m) (mm) (m) START (m) STOP (m) START (m) STOP (m) SIZE (m DIA.) SIZE (m DIA.)
SMH-4 SMH-3 24.70 24.55 23.30 22.91 200 0.40% 97 1.40 1.64 1.20 1.44 1.40 1.65 SPECIAL A
SMH-3 SMH-2 24.55 24.45 22.91 22.65 200 0.40% 65 1.64 1.80 1.44 1.60 1.65 1.65 A A
SMH-2 SMH-1 24.45 24.30 22.65 22.33 200 0.40% 81 1.80 1.97 1.60 1.77 1.65 1.65 A A

FOR 0.5% (Min for Ø200)


MH. MH. GL START GL STOP IL START IL STOP PIPE SIZE SLOPE LENGTH DEPTH TO INVERT DEPTH TO INVERT PIPE COVER PIPE COVER MH START MH STOP MH TYPE MH TYPE
START STOP (m) (m) (m) (m) (mm) (m) START (m) STOP (m) START (m) STOP (m) SIZE (m DIA.) SIZE (m DIA.)
SMH-4 SMH-3 24.70 24.55 23.30 22.82 200 0.50% 97 1.40 1.74 1.20 1.54 1.40 1.65 SPECIAL A
SMH-3 SMH-2 24.55 24.45 22.82 22.49 200 0.50% 65 1.74 1.96 1.54 1.76 1.65 1.65 A A
SMH-2 SMH-1 24.45 24.30 22.49 22.09 200 0.50% 81 1.96 2.22 1.76 2.02 1.65 1.65 A A

FOR 0.6%
MH. MH. GL START GL STOP IL START IL STOP PIPE SIZE SLOPE LENGTH DEPTH TO INVERT DEPTH TO INVERT PIPE COVER PIPE COVER MH START MH STOP MH TYPE MH TYPE
START STOP (m) (m) (m) (m) (mm) (m) START (m) STOP (m) START (m) STOP (m) SIZE (m DIA.) SIZE (m DIA.)
SMH-4 SMH-3 24.70 24.55 23.30 22.72 200 0.60% 97 1.40 1.83 1.20 1.63 1.40 1.65 SPECIAL A
SMH-3 SMH-2 24.55 24.45 22.72 22.33 200 0.60% 65 1.83 2.12 1.63 1.92 1.65 1.65 A A
SMH-2 SMH-1 24.45 24.30 22.33 21.84 200 0.60% 81 2.12 2.46 1.92 2.26 1.65 1.65 A A