Académique Documents
Professionnel Documents
Culture Documents
No: -
Tank No : 114-F Rev. 0
Tank Service : Oase Sol. Tank
Index
HLL 11700 mm
12200 mm
Center line of tank
Net Storage
Capacity
LLL 600 mm
±0
Partial
Liquid Total
Volume betn
Levels Volume
levels
Shell Top edge H 12200 mm 61 m³ 1497 m³
High Liquid Level HLL 11700 mm 1362 m³ 1436 m³
Low Liquid Level LLL 600 mm 74 m³ 74 m³
Tank Bottom 0 mm 0 m³
Materials
Yield Stres: 260 MPa
Shell Plate SA516Gr70
Tensile Stress : 485 MPa
Yield Stress : 260 MPa
Roof Plate SA516Gr70
Tensile Stress : 485 MPa
Yield Stress : 260 MPa
Bottom Plate SA516Gr70
Tensile Stress : 485 MPa
Yield Stress : 260 MPa
Top Angle/Stiffners SA516Gr70
Tensile Stress : 485 MPa
Shell courses details
Shell Course Numbers 7 Nºs
W1 Width of 1st shell course Bottom 2000 mm
W2 Width of 2nd shell course 2000 mm
W3 Width of 3rd shell course 2000 mm
W4 Width of 4th shell course 1800 mm
W5 Width of 5th shell course 1800 mm
W6 Width of 6th shell course 1800 mm
W7 Width of 7th shell course Top 800 mm ∑W1-7 = H2
Doc. No. -
Design of Storage Tanks
Tank No: 114-F Rev : 0
Tank Service: Oase Sol. Tank for Internal Pressure
API 650, 12th Ed,March-2013,Add.2 Jan-2016
Design of shell plates
Shell thickness calculation in Design & Test Conditon for each shell course
tbmin Min. required nominal thk(excl. corrosion allowance) as per 5.4.1 6.0 mm
CAb Corrosion allowance for bottom Plate 3.0 mm
tbreq Min. required bottom plate thickness : tbmin+CAb 9.0 mm
tb Provided bottom plate thickness 10.0 mm Okay
Doc. No. -
Design of Storage Tanks
Tank No: 114-F Rev : 0
Tank Service: Oase Sol. Tank for Internal Pressure
API 650, 12th Ed,March-2013,Add.2 Jan-2016
Annular bottom plate thickness calculation
Required Compression Area at the Roof-to-Shell Junction per F.5.1 of API 650
R2
Hydrotest Pressure
The maximum design pressure for a tank that has had its design details established per F4.1
size (NB) Quantity Pipe wt Flange wt No of blind Blind flange Total Wt.
inches kgs kgs flanges wt kgs
2 8 2.241 2.72 0 0.00 39.69
3 2 4.590 5.22 0 0.00 19.62
4 3 6.690 7.49 0 0.00 42.54
6 1 12.750 11.80 0 0.00 24.55
8 1 19.380 19.07 0 0.00 38.45
24 2 35.631 92.62 2 188.41 633.32
Total weight of shell incl appurtenances (Ws) Uncorroded 29.367 Tons 29.4
Corroded 18.055 Tons 18.1
Doc. No. - Rev : 0
Tank No : 114-F Weight Calculation Tank Service: Oase Sol. Tank
Bottom Plate
Bottom plate thickness ( Req./ Provided ) 9.00 mm / 10.0 mm
Uncorroded weight 12257.4 kg
Corroded weight 8580.2 kg
Total Wt of Bottom Plates Uncorroded 14589 14.589 Tons 14.589
(Wf) Corroded 10212 10.213 Tons 10.213
Roof
Plate Material SA516Gr70
Roof Plate Thickness ( Req./ Provided ) 6.5 / 8.0 mm
Weight of roof uncorroded 7813 Kg 7.814 Tons
Roof Structure corroded 6348 Kg 6.349 Tons
Weight of roof structure 2950.00 Kg
Provided weight 3000.00 Kg 3.000 Tons
Top Handrail
Weight per meter length 25 Kg/mtr
Weight of top railing 982 Kg 0.982 Tons
W1= Corroded Dead load of shell + Any other Corroded dead load excluding roof plates
= 22717 kg
= 222.8 kN
W2= Corroded Dead load of shell + Any other Corroded dead load including roof plates
= 29065 kg
= 285.0 kN
W3= UnCorroded Dead load of shell + Any other UnCorroded dead load including roof plates
= 41842 kg
= 410.3 kN
Tank No : 114-F
Wind Analysis
Tank Service: Oase Sol. Tank API 650, 12th Ed,March-2013,Add.2 Jan-2016
- Equipment class A
- Terrain Category 2 -
Vb Basic wind speed 47.20 m/s
k1 Risk Factor as per 6.3.1 1.08
k2 Terrain,height and structure size factor as per 6.3.2 1.022
k3 Topography factor as per 6.3.3 1.0
k4 Importance factor for cyclonic region as per 6.3.4 1.0
52.10 m/s
Vz Design wind speed=Vb*k1*k2*k3*k4 =47.2*1.08*1.022*1*1 as per 6.3
187.6 km/h
Vzc Considered Design wind speed 188.0 km/h
Pz wind pressure as per 7.2 = 0.6*[ Vzc/3.6]² =0.6* [188/3.6]² 1636.3 N/m²
1.636 kPa
Cf force co-efficient as per table 25 (Based on H2/D ratio =0.98) 0.7
Do Shell O.D with Insulation=D+2*(t1+tins)/1000=12.5+2*(8+0)/1000 12.516 m
= Max[1.2*Do,Do+0.6]
De Effective shell Diameter
= Max[1.2*12.516,12.516+0.6] 15.019 m
H2 Shell Height 12.200 m
Aes Shell Effective Area= De * H2 =15.019 *12.2 183.2 mm²
Ps Design wind Pressure as per wind design code Pz *Cf 1145.4 N/m²
Ps' Design Wind Pressure on shell as per 5.2.1.k 0.86 kPa
= 0.86kPa*(max(Vzc,190)/190)² = 0.86*(MAX(188,190)/190)² 860.0 N/m²
Pws Design Wind Pressue Considered 1146.0 N/m²
C.F Contingency factor on wind pressure ( if required by PMC/client spec.) 1.2
Fws Wind Load on shell= Pws * Ae * C.F = 1146*183.24*1.2 251991.65 N
Mws Wind moment on shell = Wind force * tank height/ 2
= 251991.65*12.2/2 1537149.07 N-m
Doc. No. - Rev : 0
Tank No : 114-F
Wind Analysis
Tank Service: Oase Sol. Tank API 650, 12th Ed,March-2013,Add.2 Jan-2016
Pwr1 Wind pressure on horizontal projected area of roof (As per 5.2.1.k)
=1.44kPa*(max(Vzc,190)/190)² =1.44*(MAX(188,190)/190)² 1.440 kPa
P Internal Pressure 0.883 kPa
Pmax Maximum Design Pressure per F4.1 from Int. pressuer calculation 2.943 kPa
Pwr2 Max.Design uplift pressure on the roof (wind+ internal pressure) per 5.2.1.k.2
=1.6*Pmax calculated per F4.1=1.6* 2.943 4.71 kPa
Pwr3 Wind pressure on horizontal projected area of roof as per clause 7.3.3.8 of IS 875
=(Cpi-Cpe)*Pz =(0.2-(-1) ) *1.6363 1.964 kPa
Pz Design wind pressure 1.636 kPa
Cpi Internal pressure coefficient as per clause 7.3.2.1 0.2
Cpe External pressure coefficient as per table 20 -1
As per 5.2.1.k.2,The design uplift pressue on roof (wind+Int.Pres) need not exceed 1.6*Pmax
Hence,limiting the wind uplift on roof to min of ( Max (Pwr1, Pwr3),1.6*Pmax-P)
H1c Vertical distance between intermediate wind girder and the top angle of shell
= 9.47*(tmin-CA)*((tmin-CA)/D)³)^½*(190/Vc)²
= 9.47*(5-3)*((5-3)/12.5)³)^½*(190/199)² 1.105 m
Doc. No. - Rev : 0
Tank No : 114-F
Wind Analysis
Tank Service: Oase Sol. Tank API 650, 12th Ed,March-2013,Add.2 Jan-2016
Shell
Course Uncorroded conditon Corroded conditon
Shell course no width Ls
from Bottom mm
W tuniform tactual Wtr tuniformc tactualc Wtrc
mm mm mm mm mm mm mm
1 2000 5 8 618 2 5 202.386 10.920
2 2000 5 8 618 2 5 202.386 10.920
3 2000 5 8 618 2 5 202.386 10.920
4 1800 5 6 1141 2 3 653.197 3.045
5 1800 5 5 1800 2 2 1800 1.105
6 1800 5 5 1800 2 2 1800 1.105
7 800 5 5 800 2 2 800 1.105
Total 7394.0 5660.4
Provide 1st Wind Girder at 1.10 m from Top Angle ; Unstiffened Length= 1.100 m
Provide 2nd Wind Girder at 2.20 m from Top Angle ; Unstiffened Length= 1.100 m
Provide3rd Wind Girder at 3.30 m from Top Angle ; Unstiffened Length= 1.100 m
Provide 4th Wind Girder at 4.20 m from Top Angle ; Unstiffened Length= 0.900 m
Provide 5th Wind Girder at 6.80 m from Top Angle ; Unstiffened Length= 2.600 m
Tank No : 114-F
Wind Analysis
Tank Service: Oase Sol. Tank API 650, 12th Ed,March-2013,Add.2 Jan-2016
Portion of tank shell width acting with the intermediate stiffener as per 5.9.7.6.2
Wshell 13.4 * ( D * ts-CA )^0.5 67.00 mm
Wst Total effective shell width = 2*Wshell+ta 140.0 mm
Tank No : 114-F
Wind Analysis
Tank Service: Oase Sol. Tank API 650, 12th Ed,March-2013,Add.2 Jan-2016
Dead load
H roof (DLR)
Wind load
on shell
Moments @
Dead load(DLS) shell to bottom joint
Liquid hold down weight(Wa)
Tank No : 114-F
Wind Analysis
Tank Service: Oase Sol. Tank API 650, 12th Ed,March-2013,Add.2 Jan-2016
Rwi Response reduction factor for Impulsive mode per Table: E-4 4.0
Rwc Response reduction factor for convective mode per Table: E-4 2.0
I Importance factor 1.00
K Co-efficient to adjust the spectral acceleration 1.500
Q Scaling factor 1.000
SDS Design 5% damped ,spectral response acceleration parameter at short period(0.2 sec)
=Q*Fa*Ss = 1 *1.56 * 0.3 0.468 g
SD0 Design 5% damped ,spectral response acceleration parameter at a period of zero sec
=Q*S0 = 1 *0.38 0.380 g
Ts Fv S1/ Fa Ss 0.71 sec
To 0.2*Fv S1/ Fa Ss 0.14 sec
Doc. No. -
Seismic Analysis
Tank No : 114-F Rev : 0
(Appendix E)
API 650, 12th Ed,March-2013,Add.2 Jan-2016
Time period for impulsive mode as per E:4.5.1
Ks = 0.578/(tanh(3.68*H/D))^½
= 0.578/(tanh(3.68*11.7/12.5))^½ 0.58
Wp Total weight of the tank contents based on S.G of the product 1478880 kg
14501900 N
The heightof C.G of the roof and roof apprutenances from the bottom of tank shall
Xr = H2 +(D/2)*tanθ/3
= 12.550 m
Doc. No. -
Seismic Analysis
Tank No : 114-F Rev : 0
(Appendix E)
API 650, 12th Ed,March-2013,Add.2 Jan-2016
Calculation of Seismic overturning moments
Vi Design base shear due to impulsive component from effective tank & contents weight
= Ai*(Ws+Wr+Wf+Wi) 1366289.03 N
Vc Design base shear due to the convective component of the effective sloshing weight
= Ac*Wc 416064.87 N
Tank is uplifting but tank is stable for design load if shell compression requirement is satisfied
Doc. No. -
Seismic Analysis
Tank No : 114-F Rev : 0
(Appendix E)
API 650, 12th Ed,March-2013,Add.2 Jan-2016
Check for Dynamic Hoop Tensile Stresses as per E.6.1.4
Ni = 2.6Ai G D²
= 2.60.117*1.03*12.5² 48.96 N/mm
As σt < σtallow,OK
Summary of check for Combined Dynamic hoop stress in all shell courser
Total Distance Impu. Conv. Comb.
Product
Shell Design from hoop hoop dynamic Allow.
Hydrostatic
course liquid liquid memb. memb. hoop tensile
membrane stress Result
from height surface force Force tensile stress
Bottom H Nh Y Ni Nc σT
m N/mm mm N/mm N/mm Mpa Mpa
1 11.788 724.75 11.7 48.96 2.22 158.6 199 ok
2 9.788 598.57 9.7 48.96 2.62 132.3 199 ok
3 7.788 472.40 7.7 47.58 3.95 105.9 199 ok
4 5.788 346.22 5.7 41.59 6.69 131.4 199 ok
5 3.988 232.67 3.9 32.38 11.15 135.1 199 ok
6 2.188 119.11 2.1 19.55 18.82 73.7 199 ok
7 0.388 5.55 0.3 3.09 31.90 18.8 199 ok
Doc. No. -
Seismic Analysis
Tank No : 114-F Rev : 0
(Appendix E)
API 650, 12th Ed,March-2013,Add.2 Jan-2016
Check for Shell Compression under Seismic Force as per E.6.2.2.2
Allowable Longitudinal Membrane Compression Stress in Tank Shell (Fc) per E.6.2.2.3
As GHD^2/t^2= 29.43< 44
Fc Min ((83*ts/(2.5*D))+(7.5*(G*H)^0.5)),0.5*Sy*M)
Min ((83*5/(2.5*12.5))+(7.5*(1.03*11.7)^½)),0.5*260*1)
Min (39.32,130) 39.32 MPa
ts Corroded thk of bottom shell course 5.0 mm
Uplilf Loads & Induced bolt stress calculation as per Table 5.21a
Induced bolt
stress Allow. Condtition
Uplift load case Net Uplift formula,U (N)
Sbi =U/(N*Ab) stress (Mpa) satisfied?
Mpa
-274936
2 Test Pressure [ Pt*D2*785 ] - W3 = -15.5 133 Yes
3 Wind Load Pwr *D²*785+ (4*Mws/D)-W2 = 448509 25.3 192 Yes
4 Seismic Load (4*Mrw/D)-W2*(1-0.4*Av) = 2082381 117.6 192 Yes
5 Des.P + Wind [(0.4*(P+Pwr)*D²*785]+(4*Mws/D)-W1 = 409095 23.1 133 Yes
6 Des.P + Seismic [0.4*P*D²*785]+(4*Mrw/D)-W1(1-0.4Av) = 2186316 123.4 192 Yes
7 Frangibility Pressure [(3*Pf * D² * 785)]-W3 = N/A N/A 240 N/A
b = 140 mm d e =74 mm t = 8 mm
f
c = 22
Top Plate
k tp = 8.0 mm
h = 400 mm
E = 10 mm
g = 110 j = 20 mm
Critical stress in the top plate occurs between the hole and the free edge of the plate
For convenience we can consider this portion of the top plate vas a beam with partially fixed
ends, with a portion of the total anchor bolt load distributed along part of the span,
Check for Induced stress in shell at attachment for provided skirt height
Maximum stress at the top of the chairs in vertical direction is a combination of bending plus
direct stress, based on Bjilaard formulas
S Bending stress + direct stress at top of chair as per 7-3 ( Induced stress in shell due to attachment)
=( P*e/(t+tp)² )*[ {(1.32*Z)/((1.43 a*h^2/( R*(t+tp)))+(4*a*h²)^0.333 )}+ {0.031/(R*(t+tp))^½} ]
=( P*e/(t+tp)²) * [ { A } + { B }]
= (1.08*2.92/(0.2+0.32)²) * [ {0.015} + { 0.003 } ] 0.345 ksi
B =0.031/(R*(t+tp))^½
=0.031/(246.07*(0.2+0.32)^½}] 0.003
Sa Allowable shell stress for design condition=2/3*Fty= 173 MPa 25.1 ksi
Summary of check for Induced shell stress at anchor chair attachement as per Table 5.21a
jreq Min. required gusset palte thickness = P/(25*K) = 20.49 / ( 25*7.45) 0.110 inch
2.79 mm
WV WV: Total load on weld = P/(a+2h) 2.080 kips per lin. Inch of weld
WH WH: Horizontal load = Pe/(ah+0.667h^2) 0.630 kips per lin. Inch of weld
Wa Allowable fillet weld stress =9.6*w 3.072 kips per lin. Inch of weld
Pmax Max. design pres. limited by uplift at shell base = (β/(Fp* D^3))(MDL/1.5 + MDLR - Mws)
(0.0026/(0.4*12.5^3 )*((1983693.75/1.5) +490975-1537149.07) 0.92 kPa
β Conversion factor = 8/(π*1000) 0.0026
Moment @ shell-to-bottom joint from the weight of the shell & roof supported
MDL by shell 1983693.8 N-m
Moment @ shell-to-bottom joint from nominal roof weight + attached
MDLR structural 490975.0 N-m
MF Moment @ shell-to-bottom joint from liquid weight 2527018.6 N-m
Mw Overturning moment @ shell-to-bottom joint from horizontal + vertical wind 3344792.1 N-m
Mws Wind moment on shell 1537149.1 N-m
Fp Pressure combination factor = Max(0.4,Pop/P)=Max(0.4,0) 0.4
S,Fs,Fw
Ground
B.C.D=12680 mm
To be decided by
Civil Dept
300 Min Conceret ring I.D