Camfil Farr are the world leader in providing air filtration solutions and the
product range includes many world class benchmark filters. In addition to
providing a comprehensive range of quality products, we at Camfil Farr believe
that service is of paramount importance. In today’s fast moving industries the
ability to get goods to where they are needed quickly and correctly is vital.
To ensure that our “right first time” service matches our “best in class” products
we are developing our logistics and expanding our fleet of dedicated delivery
vehicles. This unique service will ensure that your goods arrive where you want
them, when you want them. Finally, I would strongly recommend that you visit
the www.camilfarr.co.uk website where you can access much more detailed Advanced fabrication
information about our products and services, and the latest news on our capability
Bill Wilkinson
COMP 363 460
ATION is B 393
RTIFIC
NT CE RCS Par
EUROVE is FRANCE -
N° :
iploma
Par
l 75003
ation D
astopo
Certific
Séb
62 Bd de
Managing Director 34
07.01.3
fies that
ny certi
Compa
-F9
lass F5
fication
NT Certi
EUROVE ers C
Fin e Air Filt from P
ROU
F ARR G
CAMFIL Located at OSA Sw
eden
933 TR
3 , 61
igatan me
Industr Trade na
Camfil
ard
ng stand
of followi
ments
require
ing the
1-2006
cord
ssed ac
have be
en asse OM-1
d at :
displaye
ucts is n.com
fied prod ificatio Comprehensive stocks
The list
of certi
urov ent-cert
http:// www.e backed by integrated
P ance wi
th the ru
les inhouse logistics
GROU accord
L FARR mark in
CAMFI fication ual
NT Certi al Man
e th e EUROVE in the Operation
us d 2006
ised to specifie OM-11-
is author
31/01/07
al date
: 31/12/07
IST Approv
31/03/09
:
s BENO cked on
Jacque certification Re-che til :
Directo
r of Valid un
Pre-Filtration, Class G3 to F5
Cam Glass Media .................................................23 Camsure ............................................................ 67
Synthetic Media Rolls ..........................................24
Fan Coil Filter .....................................................25 Housings, frames & special applications
Hi-Cap® 30P, 40P, 50P ......................................26
Absolute Filter Holding Frame .............................. 70
Bag and Compact Filters, Class F5 to F9 Type 8 - Filter Holding Frame ............................... 71
FCB-P ............................................................ 72
Hi-Flo® M-Series .................................................29 FCBS-HF ............................................................ 73
Hi-Flo® P, PL-Series ...........................................30 FCBS-A ............................................................ 74
Hi-Flo® U-Series .................................................31 FCBL-CC ............................................................ 75
Class F5 to F9
S-Flo W P Series ..................................................34 Pharmaseal ......................................................... 78
S-Flo W U Series .................................................35 Camsafe ............................................................ 79
S-Flo W A Series ..................................................36 Termikfil 2000 ................................................... 80
Opakfil Green ......................................................37 Absolute® 1FRK ................................................. 81
Ecopleat & Ecopleat MCTA ...................................38 Paint Extract Filters ............................................. 82
Riga-Flo ............................................................39 Airopac® HT-HF ................................................. 83
OpakAir ............................................................40 Panolair SSI - Micretain H10 ............................... 84
Airopac® ............................................................41 CDM Media ........................................................ 85
H E PA / U L PA F i l t e r s , C l a s s
Cam GT® ........................................................... 86
HEPA / ULPA Filters, Class H10 to U17 Campulse EF ...................................................... 87
H10 to U17
Hi-Flo® T ........................................................... 88
Sofilair - H10 to H14 ...........................................45 Gold Series ......................................................... 89
Sofilair Green ......................................................46 HemiPleat Cartridges ........................................... 90
Close Pleat - H13 ................................................47
Opakfil G Micretain - H10 ....................................48
Megalam MD, MX, MG .........................................49
Megalam MX & MG - H14 ....................................50
Megalam MD - H10 & H14 ...................................51
1
Camfil Farr Solutions
Primary Filters
G2 ≥ 65%
Medium Efficiency
Primary Filters
EN 779:2002
G3 ≥ 80%
Primary Filtration
G4 ≥ 90%
EN 779:2002
Average Arrestance
Fine Filters
F5 ≥ 40%
High Efficiency
EN 779:2002
F6 ≥ 60%
Fine Filters
Pre-Filtration for HEPA/
Conditioning Systems.
F7 ≥ 80%
F8 ≥ 90%
Filtration for Air
F9 ≥ 95%
ULPA Filters
EN 779:2002
Average Efficiency
HEPA
100 to 1000
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
≥ 99,999% H14 ≥ 99,995%
U15 ≥ 99,9995%
ULPA
U16 ≥ 99,99995%
1 to 10
U17 ≥ 99,999995%
Molecular
CityFlo, CitySorb,
CityCarb, Camcarb
Filter Holding
Frames and
Casings
2
Camfil Farr Solutions
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
filters with less hassle and at lower cost. The use of plastics or
cardboard lends itself to the incineration of used filters whilst ensuring
compliance with all provisions of environmental law.
5. We minimise the weight of materials used in the construction of our
filters which helps reduce the waste mass as far as possible when the
filter reaches the end of its life.
6. In our ISO 14001 certified factories, we are phasing out the use of
chloride solvents and hazardous products from our processes.
4
Camfil Farr Solutions
Pre-Filtration, Class G3 to F5
In addition to providing up to date air filtration solutions Camfil Farr can
provide a structured training program covering all aspects of air
filtration engineering. Adapted to suit your needs the training includes
information on how to specify and select air filters, air filter standards,
indoor air quality legislation, air filter application, and reducing energy Air filter system validation service
and environmental impact.
Class F5 to F9
translate into long lasting real reductions in cost and environmental
impact. Camfil can provide a comprehensive package of air hygiene
services that will ensure your systems are healthy, legislation compliant,
and cost effective.
H E PA / U L PA F i l t e r s , C l a s s
Camfil Filter Management
H10 to U17
Camfil has a fresh approach to managing on-site air filtration services.
We understand that filtration is required for protecting people’s health,
ensuring legislative compliance and protecting valuable investments.
Performance Managed Supply
We have our own site service team that can manage all aspects of your Camfil complete the “cradle to grave” responsibility for all your filtration
air filter requirements by offering a wholly inclusive service package. needs by providing a unique logistics system at the centre of which is a
national transport fleet. This dedicated fleet of vehicles with trained
employees ensures that you get your goods when and where you need
them. To complete the service, we can remove and dispose of used
3
Camfil Farr Solutions
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
filters with less hassle and at lower cost. The use of plastics or
cardboard lends itself to the incineration of used filters whilst ensuring
compliance with all provisions of environmental law.
5. We minimise the weight of materials used in the construction of our
filters which helps reduce the waste mass as far as possible when the
filter reaches the end of its life.
6. In our ISO 14001 certified factories, we are phasing out the use of
chloride solvents and hazardous products from our processes.
4
Camfil Farr Solutions
Pre-Filtration, Class G3 to F5
in direct proportion to the filter’s average pressure loss.
100
80
70
60
40
15 20
Economic optimisation of air filtration 8 5
Class F5 to F9
cost of electricity is rising throughout the world. The World Bank’s t t t t t
y Cos r Cos g Cos r Cos l Cos
Energy Group has predicted that total energy consumption is set to rise erg i l t e i n b o u o s a
En F a n La p
at the current rate for at least the next 50 years. Cle Dis
The cost of ventilation
Ventilating buildings, as we know, can be a very expensive business. The
Choosing the right filter saves energy
average energy cost of filters is around 30% of the total costs of the In order to optimise the lifespan of the filter and to reduce energy
system. By choosing the right filter, for example the F7 for its efficiency consumption, it is important to bear in mind the extent to which their
and its very low average pressure loss, energy savings can be made configuration and their structure influence the average pressure loss.
whilst maintaining a high level of IAQ. When you consider that the air
H E PA / U L PA F i l t e r s , C l a s s
filter is the most inexpensive and simplest component to change,
savings can be made quickly.
Tapered pockets
H10 to U17
Parallel pockets
A rule of thumb, for a typical installation running for half of the time over For more information and assistance, please contact your
one year, is that one additional Pascal in pressure drop adds 1 euro per nearest branch of Camfil Farr.
filter in extra energy cost.
A badly designed filter construction could add 50 Pascal compared to a
well engineered filter, even if it claims to have the same efficiency. In
other words it adds 50 euros to the annual energy bill, for every filter.
A i r F i l t e r Te c h n o l o g y
5
Camfil Farr Solutions
We have made choosing filters as easy as cases we have seen that air filters may be responsible for as much as
30 percent of the total energy consumption in an air-handling unit.
ABC. Consequently, there is substantial profit to be made by choosing wisely.
The newly developed Energy & Air Quality Rating makes it easy to The Energy & Air Quality Rating helps you control your energy
reduce energy consumption and at the same time, it guarantees the air consumption. That will save you money. Actually, a lot of money.
quality. These two critical factors were taken into consideration during
the development of our new classification system. If a filter achieves a Why one of the leading filter companies
good grade, it is because it cuts costs and makes the air clean. It’s as
simple as that. cares.
We believe in transparency and honesty. The filter industry is clouded by
Honestly, how did you choose filters numbers and figures, making it virtually impossible to compare different
filters. We want to clean up the mess. Surely, the customer will profit
before? from having all the facts when deciding which filter to
Selecting the correct air filter has never been easy but choose. We believe that the industry itself will benefit from a common
the Energy & Air Quality Rating changes that. Using the standard, since it puts pressure on developers to make energy efficient
rating system, it’s easy to choose the right air filter for filters. When a company develops an excellent filter, we think it should
your needs. It’s important however, to be aware that an be rewarded with an “A”.
A-filter is not always the right choice for you. The top
rating may be appropriate for a medical or food
application where the demand for air quality is critical.
Conversely, a G-filter may be the best choice for a low-
Objectively tested.
grade storeroom. Whatever your budget and your Filter efficiency in actual use was an essential parameter when
requirement for air quality, there will be a rating letter to developing the Energy & Air Quality Rating. To guarantee independent
meet your needs. The selection process will be both verification of the discharged efficiency value, we collaborated with the
easy and precise. Technical Research Institute of Sweden (SP) - a leading organisation in
the development of sustainable energy and environmental technology in
Europe. The data was obtained through long-term measurements,
performed under realistic conditions.
It’s not just about new EU energy
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
concepts, it’s about your grandchildren. As you can see, the advantages are
The new and more stringent requirements aim to make your company obvious.
more energy efficient but the most important aspect is much closer to
home. At Camfil Farr, we are constantly striving to develop new
technologies and methods that make us even more environmentally
friendly. We want to give our children and our grandchildren the
opportunity to grow up in a clean environment. At the end of the day,
that’s what matters most.
Well, maybe not crystal clear. Differentiating air filters is a complex
matter. Many variables impact a comparison study, and not all are self-
This symbol will speak volumes in your evident. Laboratory tests are made under controlled conditions and test
protocols are an imperfect compromise of actual conditions. In actual
annual report. use, most air filters will remain in a system for months or even years.
During that time, an air filter will see hundreds of environmental changes
such as temperature, humidity, airflow velocity and particle load. Add to
this the fact that it is not impossible for suppliers to manipulate
observations or data to best suit their needs. With the Energy & Air
Quality Rating all you really need to look at is a single letter. All in all, we
like to think the advantages are quite obvious.
6
Camfil Farr Solutions
Environmental Health hydrocarbons are emitted by the incomplete burning of fuels or carbon,
which can usually be found in the air, linked to particles. Some of them
Environmental health is becoming a central concern at national and are known to be highly carcinogenic.
international levels. Indoor Air Quality (IAQ) is an area that focuses on
providing a comfortable and healthy indoor environment which is
important to the well being of people. We spend 80% of our time in
Pre-Filtration, Class G3 to F5
indoor spaces and, as such, the issue of IAQ is a key aspect of public
health, especially since this affects the entire population, particularly the
most sensitive and vulnerable.
The industrialised world is a very different place compared to 50 years
ago and one major difference is that the air we breathe is now more
heavily and more diversely polluted than at any time in the past.
Although natural sources of pollution exist, the greater concerns arise
as a result of mans own activities which have increased both the amount
and the complexity of pollutants found in the atmosphere. There are tens
of thousands of synthetic chemicals (not found in nature) made today
with an estimated annual production rate in excess of a billion tonnes.
Class F5 to F9
an inevitable part of our lives Secondary pollutants are substances whose presence in the
. atmosphere is the result of chemical transformations related to the
interaction of compounds known as precursors. Ozone is the main
secondary pollutant, it is formed as a result of a photochemical process
in the presence of certain primary pollutants (carbon monoxide, nitric
oxide and volatile organic compounds). This is a gas that is naturally
present in the atmosphere in low concentrations at high altitude. At low
altitude, on the other hand, the development of the concentration is
primarily the result of human activity. Sulphuric acid and nitric acid form
H E PA / U L PA F i l t e r s , C l a s s
in the atmosphere as a result of humidity from sulphur dioxide and nitric
oxide respectively.
H10 to U17
Solid pollutants
Solid pollutants usually in the form of small (fine) particles are very
important and from a cleanliness point of view, these particles deserve
particular attention. These are capable of acting as vectors to other
substances, such as carcinogenic polycyclic aromatic hydrocarbons,
Atmospheric pollution which is particularly worrying given the capacity of the finest particles (<
1μm) to find their way into the lungs and even to penetrate into the
Atmospheric pollution can be categorised in two different ways. The bloodstream. Effective solutions aimed at combating such particle
simplest is measurement (a physical categorisation) to distinguish pollution are now widely known. The development of the main standards
gaseous pollutants from solid, dust and particulate pollutants. The and recommendations governing the manufacture and use of modern air
second is based on the origin of pollutants and is divided into primary filters is clearly geared towards much higher filtration levels than have
and secondary pollutants. been permitted in the past
prominent:
Sulphur dioxide (SO2) emitted by certain industrial processes, such as CITYCARB and CITYFLO combine particulate filtration with pollution
paper-making and refining, and in particular by the use of sulphurous and odour filtration. They are suitable for any new installation and can be
fossil fuels. SO2 is one of the main causes of acid rain on account of its readily installed to upgrade and improve systems currently equipped
transformation in the atmosphere into sulphuric acid (H2 SO4). Nitric with standard filters.
oxides (NOX), and in particular nitrogen dioxide (NO2), which is usually With its higher molecular adsorption, CITYSORB is ideal for highly
emitted from the burning of fossil fuels (particularly vehicles), contribute polluted urban environments. CITYSORB must be fitted in conjunction
towards the formation of ozone in the atmosphere. Polycyclic aromatic with a particulate filter above F7 efficiency, HIFLO or OPAKFIL type.
A i r F i l t e r Te c h n o l o g y
7
Camfil Farr Solutions
AT E X
ATEX Directive: Explosive atmospheres biopharmaceutical applications, some procedures must use ATEX-
classified filters in certain places (please see table). Camfil Farr in
Two important new safety directives have entered into force in Europe. Europe has developed HEPA filters and ATEX accredited housings for
These new regulations come under the title of ATEX Directives and apply use in biopharmaceutical installations in order to prevent electrostatic
to manufacturers, suppliers and users of equipment intended for use in dangers caused by gas or dust in an ATEX area. Camfil Farr has
potentially explosive atmospheres (dangerous areas). An explosive developed specific versions of ATEX for most filters and housings used
atmosphere is defined as a mixture with air, under atmospheric in biopharmaceutical installations in order to prevent electrostatic
conditions, of hazardous substances in the form of gases, vapours, dangers caused by gas or dust in an ATEX area. Camfil Farr’s ATEX
mists or dusts in which, after ignition has occurred, combustion spreads solutions are entirely certified in accordance with the requirements of
to the entire unburned mixture. The 99/92/EC (ATEX 137) Directive, the ATEX Directives with the appropriate EX marking, the ATEX
known as the ‘User Directive’ requires employers to protect their conformity statement and the instructions for use.
employees from the risks posed by explosive atmospheres. The 94/9/
EC (ATEX 95 or ATEX 100A) Directive on ‘Equipment and protective
systems intended for use in potentially explosive atmospheres’ covers Key to the table:
electrical and non-electrical products intended for use in hazardous Definition of ATEX areas and corresponding product categories.
places (gases, vapours, mists). Conformity with the ATEX Directives has
Definitions of areas
been a legal requirement in all EU Member States since 1 July 2003. In
Dust Category
Gas Definitions Typical suitability of place
Areas ATEX
0 20 1G Equipment adapted to 0 areas
Place where an explosive atmosphere is permanently present
1D Equipment adapted to 20 areas
1 21 Place where an explosive atmosphere is probable occasionally under normal 2G Equipment adapted to 1 areas
operating conditions 2D Equipment adapted to 21 areas
2 22 Place where an explosive atmosphere is improbable under normal operating 3G Equipment adapted to 2 areas
conditions, but, where applicable, only lasts a short time. 3D Equipment adapted to 22 areas
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
8
Camfil Farr Solutions
Concerns over public health have resulted in increased awareness about indoor air quality (IAQ). We now spend approximately 80% of our time in indoor
spaces and legislation now requires that these spaces are comfortable, safe and without risk to health. Camfil Farr filters for air conditioning systems
help to safeguard human health by preventing airborne contamination from entering these environments. In addition correctly selected and maintained air
filters keep air conditioning systems clean ensuring that they perform in accordance with design parameters. Camfil Farr’s extensive range of comfort air
Pre-Filtration, Class G3 to F5
filters, are typically used in offices, schools and shopping centres etc.
1, 2, 6, 7 or 8 1, 2, 3, 4, 5 or 6
5 or 9 5
5
5 or 9
1, 2, 6, 7 or 8
Class F5 to F9
5 3, 10
H E PA / U L PA F i l t e r s , C l a s s
IAQ recommendations
H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
9
Camfil Farr Solutions
Nowhere is air filtration more important than in health care facilities. Air filters offer excellent protection from airborne diseases in health care facilities,
provided that they form part of an overall air quality control programme. Camfil Farr provides a comprehensive solution that ensures the provision of this
quality. Our extensive scope of supply ranges from providing air filters to satisfy the most demanding standards, air filter housings, system validation and
monitoring, filter management, and specialist consultancy services. Our products provide safe and comfortable environments for patients, visitors and
healthcare professionals.
1 2
3, 4
5, 6 5, 6
6, 8
7, 9 7, 9
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
1. Hi-Flo F7 2. Opakfil Green F8 3. Sofilair H13 4. FC-Filter Casing 5. Sofdistri
10
Camfil Farr Solutions
For more than forty years Camfil Farr has been a leading supplier of air filter products and services to the Bio-Pharma Industry. Many of our clients have
multiple facilities located around the world. Camfil Farr is viewed by many of the largest pharmaceutical manufacturers as a partner and well positioned
to support their air filtration demands on a local and global basis.
Pre-Filtration, Class G3 to F5
1 2 3, 14
6, 8 7, 8, 9, 10 4, 5
Class F5 to F9
8, 11 3, 11, 15
H E PA / U L PA F i l t e r s , C l a s s
Pharmaceutical Industry recommendations
H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
11. Sofdistri Exhaust 12. Camsafe 13. Airopac/Opakair 14. FC - Filter Casing 15. Ecopleat F6
A i r F i l t e r Te c h n o l o g y
11
Camfil Farr Solutions
Food Industry
Protecting human health is a major concern for governments throughout the world. In many countries agencies associated with food safety have the
authority to take direct action against manufacturers who fail to ensure the safety of foodstuffs that they produce. To prevent the air conditioning system
from becoming contaminated, temperature, humidity and cleanliness must be closely controlled. Talk with the experts in clean air solutions - Camfil Farr.
1, 2 3
3
4, 5
6, 7
8, 9, 10
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
1. Hi Flo F7 2. S-Flo F7 3. Opakfil F8 4. Sofilair H13 5. FC - Filter Casing
12
Camfil Farr Solutions
Few industrial applications demand such a clean working environment as painting facilities. Paint spraying facilities require a constant supply of fresh air
for hygiene and safety reasons. We currently provide clean air and services to many major automotive plants throughout the world. We provide the best
possible cost effective clean air solutions, customised and performance-optimised to meet your demands. Supplied and delivered exactly according to
your needs – by Camfil Farr.
Pre-Filtration, Class G3 to F5
8, 9, 1, 2, 3 8, 9, 1, 2, 3 8, 9, 1, 2, 3 8, 9, 1, 2, 3
H E PA / U L PA F i l t e r s , C l a s s
Automotive Industry recommendations
H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
13
Camfil Farr Solutions
Microelectronic Industry
Advanced production methods often require very clean air, and as technology advances these requirements look likely to increase. Camfil Farr is
recognised as the leading supplier of high efficiency filtration products for the microelectronics industry. HEPA/ULPA filters are produced within controlled
environments in our ISO 9000-certified plants and are individually tested and certifed to ensure compliance. Our large production capacity ensures the
availability of our products at all times throughout the world.
1, 2 2, 3, 4
4, 5
7 6 8 1, 2 or 3
1, 2
2, 3, 4
4, 5 4, 5
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
1. Hi-Flo F7/F8 2. Opakfil Green F8/H10 3. Camcarb 4. Sofilair H13/H14 5. Gigapleat
14
Camfil Farr Solutions
Camfil Farr provides systems solutions for the turbo machinery and power systems industry. Our solutions include filters, ducting, fans, silencers, and de-
icing. With more than 40 years of experience, Camfil Farr delivers value to customers worldwide whilst providing everyone with something essential -
clean air.
Pre-Filtration, Class G3 to F5
1, 2, 3, 4, 5, 8
6, 7
H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
15
Camfil Farr Solutions
Camfil Farr provides systems solutions for the turbo machinery and power systems industry. Our solutions include filters, ducting, fans, silencers, and de-
icing. With more than 40 years of experience, Camfil Farr delivers value to customers worldwide whilst providing everyone with something essential -
clean air.
Pre-Filtration, Class G3 to F5
1, 2, 3, 4, 5, 8
6, 7
H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
15
Camfil Farr Solutions
Notes
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
16
Pre-Filtration, Class G3 to F5
Pre-Filtration, Class G3 to F5
Pleated Filters Pleated Filters Panel Filters Pad Filters
30/30 Aeropleat PP Camglass GP Pad Holding Frame
Page 18 Page 19 Page 20 Page 21
H E PA / U L PA F i l t e r s , C l a s s
H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
17
Pre-Filtration, Class G3 to F5
Pleated Filters
30/30
Advantages
• High mechanical strength • Large media surface
• Fully supported media bonded • Unique radial pleat design
onto a wire support grid • Bonded into case to eliminate
• Rigid, water resistant cardboard air bypass
frame
W
IE
DI
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
059413-002 30/30 Panel 30/30-12244NOM 305x610x100 G4 2070/90 1,28 0,75 0,02 E
059413-004 30/30 Panel 30/30-16204NOM 406x508x100 G4 2250/90 1,45 0,85 0,02 E
059413-005 30/30 Panel 30/30-16254NOM 406x635x100 G4 2880/90 1,82 1,05 0,04 E
059413-003 30/30 Panel 30/30-20204NOM 508x508x100 G4 2880/90 1,73 1,05 0,04 E
059413-008 30/30 Panel 30/30-20244NOM 508x610x100 G4 3420/90 2,09 1,25 0,04 E
059413-006 30/30 Panel 30/30-20254NOM 508x635x100 G4 3600/90 2,18 1,30 0,04 E
059413-001 30/30 Panel 30/30-24244NOM 610x610x100 G4 4140/90 2,56 1,45 0,04 E
054862-010 30/30 Panel 30/30-12241NOM 305x610x25 G4 1310/65 0,42 0,25 0,01 G
054862-001 30/30 Panel 30/30-16201NOM 406x508x25 G4 1460/65 0,45 0,30 0,01 G
054862-004 30/30 Panel 30/30-16251NOM 406x635x25 G4 1840/65 0,57 0,35 0,01 G
054862-002 30/30 Panel 30/30-20201NOM 508x508x25 G4 1800/65 0,56 0,35 0,01 G
054862-933 30/30 Panel 30/30-20241NOM 508x610x25 G4 2200/65 0,68 0,40 0,01 G
054862-003 30/30 Panel 30/30-20251NOM 508x635x25 G4 2300/65 0,71 0,45 0,01 G
054862-005 30/30 Panel 30/30-24241NOM 610x610x25 G4 2600/65 0,83 0,50 0,01 G
Other dimensions are available on request - All dimensions are nominal.
18
Pre-Filtration, Class G3 to F5
Aeropleat PP
Advantages
• Moisture resistant cardboard • Fully supported media bonded
Pre-Filtration, Class G3 to F5
frame onto a wire support grid
• Comprehensive range of • Bonded into case to eliminate
standard and non standard air by-pass
sizes • Robust construction
D
IE
DI
VI
W
F
DU
ALLY CER
TI
Class F5 to F9
Recommended final pressure drop: 250 Pa.
Temperature: 70°C maximum in continuous service.
Holding frames: Front and side access housings and frames are available, Type 8, Type L, and
FC Housings.
H E PA / U L PA F i l t e r s , C l a s s
PP12122NOM Aeropleat PP PP12122NOM 305x305x50 G4 820/70 0,26 0,20 0,01 G
PP12242NOM Aeropleat PP PP12242NOM 305x610x50 G4 1620/70 0,53 0,35 0,01 G
H10 to U17
PP16202NOM Aeropleat PP PP16202NOM 406x508x50 G4 1830/70 0,63 0,40 0,01 G
PP16252NOM Aeropleat PP PP16252NOM 406x635x50 G4 2300/70 0,79 0,50 0,02 G
PP20202NOM Aeropleat PP PP20202NOM 508x508x50 G4 2290/70 0,75 0,50 0,02 G
PP20242NOM Aeropleat PP PP20242NOM 508x610x50 G4 2750/70 0,91 0,55 0,02 G
PP20252NOM Aeropleat PP PP20252NOM 508x635x50 G4 2880/70 0,95 0,60 0,02 G
PP24242NOM Aeropleat PP PP24242NOM 610x610x50 G4 3240/70 1,10 0,65 0,02 G
19
Pre-Filtration, Class G3 to F5
Panel Filters
Camglass GP
Advantages
• Robust construction • Moisture resistant cardboard
• Comprehensive range of frame
standard and non standard • Gradual density media to
sizes improve dust holding capacity
EN 779:2002 Holding frames: Front and side access housings and frames are available, Type 8, Type L, and
IN
D
IE
W
DI
VI F
DU
ALLY CER
TI
D FC Housings.
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
GP24242NOM Camglass GP GP24242NOM 610x610x50 G3 0.37 2400/50 0.02 0.40
GP12241NOM Camglass GP GP12241NOM 305x610x25 G2 0.19 1200/45 0.01 0.20
GP15151NOM Camglass GP GP15151NOM 381x381x25 G2 0.15 990/45 0.01 0.15
GP15201NOM Camglass GP GP15201NOM 381x508x25 G2 0.19 1315/45 0.01 0.20
GP16201NOM Camglass GP GP16201NOM 406x508x25 G2 0.21 1400/45 0.01 0.20
GP16251NOM Camglass GP GP16251NOM 406x635x25 G2 0.26 1750/45 0.01 0.25
GP18181NOM Camglass GP GP18181NOM 457x457x25 G2 0.21 1400/45 0.01 0.20
GP20201NOM Camglass GP GP20201NOM 508x508x25 G2 0.26 1750/45 0.01 0.25
GP20241NOM Camglass GP GP20241NOM 508x610x25 G2 0.31 1460/45 0.01 0.30
GP20251NOM Camglass GP GP20251NOM 508x635x25 G2 0.32 2100/45 0.01 0.35
GP24241NOM Camglass GP GP24241NOM 610x610x25 G2 0.37 2400/45 0.01 0.40
Other sizes are available on request. All dimensions are nominal.
20
Pre-Filtration, Class G3 to F5
Advantages
• Robust construction • Retaining wire for media pad
Pre-Filtration, Class G3 to F5
• Replaceable filter media • Suitable for commercial and
• Support mesh downstream industrial applications
EN 779:2002
Humidity: 100% RH.
IN
D
IE
DI
VI F
W
TI
Class F5 to F9
DU
ALLY CER
H E PA / U L PA F i l t e r s , C l a s s
AMZ12242 NOM PHF-2S 2" POLY 292x597x45 G3 / G4 1620/109 0,18 0,6 0,007
AMZ24241 NOM PHF-1S T15-350 597x597x25 G3 / G4 1924/25 0,36 1,0 0,007
H10 to U17
AMZ20241 NOM PHF-1S T15-350 495x597x25 G3 / G4 1595/25 0,30 0,9 0,005
AMZ12241 NOM PHF-1S T15-350 292x597x25 G3 / G4 941/25 0,18 0,6 0,003
AMZ24242 NOM PHF-2G 2" GLASS 597x597x45 G3 3240/60 0,36 1,2 0,016
AMZ20242 NOM PHF-2G 2" GLASS 495x597x45 G3 2700/60 0,30 1,0 0,013
AMZ12242 NOM PHF-2G 2" GLASS 292x597x45 G3 1620/60 0,18 0,6 0,007
AMZ24241 NOM PHF-1G 1" GLASS 597x597x25 G2 3240/50 0,36 1,0 0,007
AMZ12241 NOM PHF-1G 1" GLASS 292x597x25 G2 1620/50 0,18 0,6 0,003
Other sizes available on request - Alternative constructions also available.
21
Pre-Filtration, Class G3 to F5
Metal Panels
EcoFlo
Advantages
• Totally washable • High mechanical strength
• Low pressure drop • Suitable for high air flow
• Support mesh on both sides conditions
Application: Kitchen extract systems, Pre filtration within air conditioning systems.
Type: Grease elimination or coarse dust removal.
Frame: Galvanised Mild Steel.
Media: Knitted or multilayer pad.
EN 779:2002 efficiency: G2, G3.
TIFICAT
ER
Arrestance efficiency: 65% - 80%.
E
C
EN 779:2002
Eurovent 4/5 efficiency: EU2, EU3.
IN
D
IE
DI
VI
W
F
DU TI
ALLY CER
D Temperature: 100°C maximum in continuous service.
Humidity: 100% RH.
Accessories: Handles and drain holes.
Optional: Alternate materials available on request e.g. Stainless Steel.
Holding frames: Front and side access housings and frames are available, Type 8, Type L, and
FC Housings.
Unit Unit
Dimensions Filter classification Air flow/pressure drop Media volume
Reference Type Model weight
WxHxD (mm) EN 779:2002 (m³/hr/Pa) area (m 2 ) (kg) (m 3 )
GFP12122NOM EcoFlo GFP12122NOM 292x292x45 G2 810/30 0,09 1,2 0,004
GFP12242NOM EcoFlo GFP12242NOM 292x596x45 G2 1620/30 0,18 2,3 0,005
GFP20202NOM EcoFlo GFP20202NOM 495x495x45 G2 2250/30 0,25 3,4 0,011
GFP20242NOM EcoFlo GFP20242NOM 495x596x45 G2 2700/30 0,30 4,0 0,013
GFP24242NOM EcoFlo GFP24242NOM 596x596x45 G2 3240/30 0,36 4,5 0,016
MMP12122NOM EcoFlo MMP12122NOM 292x292x45 G3 810/40 0,09 1,2 0,004
MMP12242NOM EcoFlo MMP12242NOM 292x596x45 G3 1620/40 0,18 2,3 0,005
MMP20202NOM EcoFlo MMP20202NOM 495x495x45 G3 2250/40 0,25 3,4 0,011
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
MMP20242NOM EcoFlo MMP20242NOM 495x596x45 G3 2700/40 0,30 4,0 0,013
MMP24242NOM EcoFlo MMP24242NOM 596x596x45 G3 3240/40 0,36 4,5 0,016
Other dimensions available on request - Alternative constructions also available.
22
Pre-Filtration, Class G3 to F5
Advantages
• Continous filament glass fibres, • Full depth particle collection
Pre-Filtration, Class G3 to F5
resin bonded • Economical
• Smooth airflow through booths
Application: For use as a pre filter in air conditioning, and spraybooth extract systems.
Media: Glass Fibre.
TIFICAT
ER
EN 779:2002 efficiency: G2 / G3.
E
C
EN 779:2002
Arrestance efficiency: 75% - 85%.
IN
D
IE
DI
VI F
DU TI
ALLY CER
H E PA / U L PA F i l t e r s , C l a s s
PR50150040 50 mm PR 50 1.5 x 40 G2 60.00 1.8 / 30 600 3.00
PR50182920 50 mm PR 50 1.829 x 20 G2 36.58 1.8 / 30 600 1.829
H10 to U17
PR50220 50 mm PR 50 2.0 x 20 G2 40.00 1.8 / 30 600 2.00
PR50230 50 mm PR 50 2.0 x 30 G2 60.00 1.8 / 30 600 3.00
PR7571040 75 mm PR 75 0.710 x 40 G2 28.40 1.8 / 35 750 2.13
PR10076220 100 mm PR 100 0.762 x 20 G2 15.24 1.8 / 40 900 1.524
PR100120 100 mm PR 100 1.0 x 20 G2 20.00 1.8 / 40 900 2.00
PR100140 100 mm PR 100 1.0 x 40 G2 40.00 1.8 / 40 900 4.00
23
Pre-Filtration, Class G3 to F5
Media Rolls
Advantages
• Smooth airflow through booths • Progressively built up thermal
• Non toxic bonded polyester fibre
Application: For use as a pre filter in air conditioning, and spraybooth ventilation.
Flammability: (DIN 53438) self extinguishing.
Media: Synthetic.
EN 779:2002 efficiency: G2, G3, G4.
Arrestance efficiency: 65% - 92%.
Eurovent 4/5 efficiency: EU2, EU3, EU4.
ER
TIFICAT Temperature: 80°C - 100°C maximum in continuous service.
E
C
D
IE
DI
VI F
DU TI
ALLY CER
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
24
Pre-Filtration, Class G3 to F5
Advantages
• Available in a wide variety of • Low pressure drop
Pre-Filtration, Class G3 to F5
sizes • Light and robust
• Economical
Application: Prevention of dust and dirt build up on heating/cooling coils within ventilation
systems.
Type: Coarse dust removal.
Frame: Metal with downstream support.
Media: Synthetic.
EN 779:2002 efficiency: G2.
Arrestance efficiency: 65%.
Class F5 to F9
Humidity: 100% RH.
TIFICAT
ER
E
C
EN 779:2002
IN
W
IE
DI
VI F
TI
D
DU
ALLY CER
Filter classification EN
Reference Type Model Dimensions (WxHxD) mm 779:2002
CircaSyn (size mm) T15-150 pad CircaSyn as required G2
H E PA / U L PA F i l t e r s , C l a s s
CircaFoam (size mm) 20PPI foam CircaFoam as required G2
Alternative filter materials also available - Other dimensions available on request - Alternative constructions also available.
H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
25
Pre-Filtration, Class G3 to F5
Advantages
• Rigid self supporting pockets • Welded pocket construction
• Robust metal header frame • High mechanical strength
EN 779:2002
IN
D
IE
DI
VI F
DU TI
ALLY CER
W D
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
2015540P25* Hi-Cap 40P 20/15/5/40P/25* 490x592x380 G4 5 2.3 2800/40 0.05 2.0 F
1215340P25* Hi-Cap 40P 12/15/3/40P/25* 287x592x380 G4 3 1.4 1700/40 0.03 1.4 F
2420640P25* Hi-Cap 40P 24/20/6/40P/25* 592x592x500 G4 6 3.6 3400/35 0.05 2.7 F
2020540P25* Hi-Cap 40P 20/20/5/40P/25* 490x592x500 G4 5 3.0 2800/35 0.05 2.5 F
1220340P25* Hi-Cap 40P 12/20/3/40P/25* 287x592x500 G4 3 1.8 1700/35 0.03 1.6 F
2415650P25* Hi-Cap 50P 24/15/6/50P/25* 592x592x380 F5 6 2.7 3400/80 0.05 2.4 F
2015550P25* Hi-Cap 50P 20/15/5/50P/25* 490x592x380 F5 5 2.3 2800/80 0.05 2.2 F
1215350P25* Hi-Cap 50P 12/15/3/50P/25* 287x592x380 F5 3 1.4 1700/80 0.03 1.6 F
2420650P25* Hi-Cap 50P 24/20/6/50P/25* 592x592x500 F5 6 3.6 3400/75 0.05 3.0 F
2020550P25* Hi-Cap 50P 20/20/5/50P/25* 490x592x500 F5 5 3.0 2800/75 0.05 2.8 F
1220350P25* Hi-Cap 50P 12/20/3/50P/25* 287x592x500 F5 3 1.8 1700/75 0.03 1.8 F
Other sizes are available on request - 25* denotes a 25 mm header frame, if a 20 mm header frame is required please specify 20*.
26
Bag and Compact Filters, Class F5 to F9
Pre-Filtration, Class G3 to F5
Bag Filters Glass Fibre Bag Filters Glass Fibre Bag Filters Glass Fibre Bag Filters Glass Fibre
® ® ®
Hi-Flo M-Series Hi-Flo P, PL-Series Hi-Flo U-Series Hi-Flo® A-Series
Page 29 Page 30 Page 31 Page 32
H E PA / U L PA F i l t e r s , C l a s s
Page 34 Page 35 Page 36
H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
Compact Filter High Efficiency Panel Pleated Compact Filter Pleated Compact Filter
Opakfil Green Ecopleat & Ecopleat MCTA Riga-Flo OpakAir
Page 37 Page 38 Page 39 Page 40
27
Bag and Compact Filters, Class F5 to F9
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
• Published data must be correct airflow.
• The products must comply with the EN 779:2002 The filters are tested at independent test laboratories - in Sweden, the
standard Technical Research Institute of Sweden, SP, in Borås; in Finland, VTT in
• Filters must be tested by independent laboratories - Espoo. These are the only laboratories in Europe that are accredited to
SP in Sweden and VTT in Finland ISO 17025.
• The test laboratories must be ISO 17025 certified The test laboratories are not told which company’s products they are
• We as manufacturers must be quality certified to ISO testing, but are only given a number that Eurovent assigns to each
9000 or a corresponding standard individual filter.
• Each year, Eurovent selects, at random, four new Tolerance levels for initial pressure drop defined in EN 779:2002:
filters from our range for inspection +(10%+Mt) or +(10Pa+Mt), whichever is highest. Mt = 5Pa (tolerance
Read more on Eurovent’s website: www.eurovent-certification.com level defined in EN 779:2002)
Eurovent’s certification of our fine-dust filters means that you can rest
assured that we live up to the performance requirements and the data TIFICAT
ER
E
C
D
IE
DI
VI F
DU TI
guaranteed! ALLY CER
28
Bag and Compact Filters, Class F5 to F9
Hi-Flo ® M-Series
Advantages
• Rubust construction • Comprehensive range of
Pre-Filtration, Class G3 to F5
• Save energy - optimised design standard sizes
(LCC) • Certified performance
• Controlled media spacing • Large surface area
(CMS)
EN 779:2002
Recommended final pressure drop: 450 Pa (suggested economical change point 250Pa).
IN
Class F5 to F9
IE
DI
VI F
DU TI
ALLY CER
D
Temperature: 70°C maximum in continuous service.
Holding frames: Front and side access housings and frames are available, Type 8, Type L, and
FC Housings.
EFFICIENCY
GUARANTEE
H E PA / U L PA F i l t e r s , C l a s s
H10 to U17
Filter Unit Unit
Dimensions of Media Air flow/pressure
classification EN Number volume Energy
Reference Type Model weight
(WxHxD) pockets area m 2 drop m 3 /hr/Pa Rating
779:2002 kg m3
535025A1 Hi-Flo M6 592x592x635 F6 12 9.2 3400/65 3.3 0.05 B
535002A1 Hi-Flo N6 490x592x635 F6 10 7.7 2800/64 3.0 0.05 B
535026A1 Hi-Flo O6 287x592x635 F6 6 4.6 1700/65 1.9 0.03 B
535025A2 Hi-Flo M7 592x592x635 F7 12 9.2 3400/85 2.9 0.05 A
29
Bag and Compact Filters, Class F5 to F9
Hi-Flo ® P, PL-Series
Advantages
• Large surface area • Comprehensive range of
• Rubust construction standard sizes
• Controlled media spacing • Low pressure drop
(CMS) • Certified performance
EN 779:2002
Recommended final pressure drop: 450 Pa (suggested economical change point 250 Pa).
Temperature: 70°C maximum in continuous service.
IN
D
IE
DI
W
VI F
DU TI
D
ALLY CER
Holding frames: Front and side access housings and frames are available, Type 8, Type L, and
FC Housings.
EFFICIENCY
GUARANTEE
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
535005A2 Hi-Flo Q7 490x592x534 F7 8 5.2 2700/105 2.4 0.05 B
535028A2 Hi-Flo R7 287x592x534 F7 5 3.2 1700/105 1.6 0.03 B
535027A3 Hi-Flo P9 592x592x534 F8 10 6.5 3400/150 2.4 0.05 B
535005A3 Hi-Flo Q9 490x592x534 F8 8 5.2 2700/150 2.4 0.05 B
535028A3 Hi-Flo R9 287x592x534 F8 5 3.2 1700/150 1.6 0.03 B
536004A1 Hi-Flo PL6 592x892x534 F6 10 9.7 5100/70 4.4 0.10 B
536005A1 Hi-Flo QL6 490x892x534 F6 8 7.8 4200/70 4.0 0.11 B
536006A1 Hi-Flo RL6 287x892x534 F6 5 4.8 2550/70 2.6 0.05 B
536004A2 Hi-Flo PL7 592x892x534 F7 10 9.7 5100/110 3.8 0.11 B
536005A2 Hi-Flo QL7 490x892x534 F7 8 7.8 4200/110 3.6 0.11 B
536006A2 Hi-Flo RL7 287x892x534 F7 5 4.8 2550/110 2.2 0.05 B
536004A3 Hi-Flo PL9 592x892x534 F8/9 10 9.7 5100/153 4.1 0.11 B
536005A3 Hi-Flo QL9 490x892x534 F8/9 8 7.8 4200/154 3.7 0.11 B
536006A3 Hi-Flo RL9 287x892x534 F8/9 5 4.8 2550/151 2.5 0.05 B
Other sizes are available on request - *Supplied with a 25mm header as standard. 20mm header available on request.
30
Bag and Compact Filters, Class F5 to F9
Hi-Flo ® U-Series
Advantages
• Large surface area • Controlled media spacing
Pre-Filtration, Class G3 to F5
• Comprehensive range of (CMS)
standard sizes • High dust holding capacity
• Rubust construction • Certified performance
EN 779:2002
Eurovent 4/5 efficiency: EU5, EU6, EU7, EU8.
W
IE
DI
VI F
DU TI
ALLY CER
D Recommended final pressure drop: 450 Pa (suggested economical change point 250 Pa).
Temperature: 70°C maximum in continuous service.
Class F5 to F9
Holding frames: Front and side access housings and frames are available, Type 8, Type L, and
FC Housings.
EFFICIENCY
GUARANTEE
H E PA / U L PA F i l t e r s , C l a s s
Dimensions Filter classification Number of Media Air flow/pressure drop Unit Unit volume Energy
Reference Type Model (WxHxD) EN 779:2002 pockets area m 2 m 3 /hr/Pa weight kg m3 Rating
H10 to U17
*35606060U Hi-Flo *3U-4050/6060/60 592x592x600 F5 8 6.0 3400/50 2.8 0.05 C
*35606038U Hi-Flo *3U-4050/6060/38 592x592x380 F5 8 3.8 2700/75 2.3 0.05 C
*35506060U Hi-Flo *3U-4050/5060/60 490x592x600 F5 6 4.6 2800/55 2.4 0.05 C
*35506038U Hi-Flo *3U-4050/5060/38 490x592x380 F5 6 2.9 2250/80 1.9 0.05 C
*35306060U Hi-Flo *3U-4050/3060/60 287x592x600 F5 4 3.0 1700/50 1.6 0.03 C
*35306038U Hi-Flo *3U-4050/3060/38 287x592x380 F5 4 1.9 1350/75 1.4 0.03 C
*36606060U Hi-Flo *3U-65/6060/60 592x592x600 F6 8 6.0 3400/80 2.8 0.05 B
31
Bag and Compact Filters, Class F5 to F9
Hi-Flo ® A-Series
Advantages
• High dust holding capacity • Robust construction
• Controlled media spacing • Comprehensive range of
(CMS) standard sizes
EN 779:2002 Holding frames: Front and side access housings and frames are available, Type 8, Type L, and
IN
W
IE
DI
VI
FC Housings.
F
D
DU TI
ALLY CER
EFFICIENCY
GUARANTEE
Dimensions Filter classification Number of Media Air flow/pressure drop Unit Unit volume Energy
Reference Type Model
(WxHxD) EN 779:2002 pockets surface m 2 m 3 /hr/Pa weight kg m3 Rating
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
*35306038A Hi-Flo *3A-4050/3060/38 287x592x380 F5 3 1.5 1350/70 1.3 0.03 D
*36606060A Hi-Flo *3A-65/6060/60 592x592x600 F6 6 4.7 3400/70 2.4 0.05 B
*36606038A Hi-Flo *3A-65/6060/38 592x592x380 F6 6 2.9 2700/95 2.0 0.05 B
*36506060A Hi-Flo *3A-65/5060/60 490x592x600 F6 5 3.9 2800/75 2.1 0.05 B
*36506038A Hi-Flo *3A-65/5060/38 490x592x380 F6 5 2.4 2250/100 1.8 0.05 B
*36306060A Hi-Flo *3A-65/3060/60 287x592x600 F6 3 2.3 1700/70 1.5 0.03 B
*36306038A Hi-Flo *3A-65/3060/38 287x592x380 F6 3 1.5 1350/95 1.3 0.03 B
*37606060A Hi-Flo *3A-85/6060/60 592x592x600 F7 6 4.7 2700/105 2.4 0.05 C
*37606038A Hi-Flo *3A-85/6060/38 592x592x380 F7 6 2.9 2150/135 2.0 0.05 C
*37506060A Hi-Flo *3A-85/5060/60 490x592x600 F7 5 3.9 2250/100 2.1 0.05 C
*37506038A Hi-Flo *3A-85/5060/38 490x592x380 F7 5 2.4 1800/130 1.8 0.05 C
*37306060A Hi-Flo *3A-85/3060/60 287x592x600 F7 3 2.3 1350/115 1.5 0.03 C
*37306038A Hi-Flo *3A-85/3060/38 287x592x380 F7 3 1.5 1100/145 1.3 0.03 C
*38606060A Hi-Flo *3A-95/6060/60 592x592x600 F8 6 4.7 2700/175 2.4 0.05 C
*38606038A Hi-Flo *3A-95/6060/38 592x592x380 F8 6 2.9 2150/220 2.0 0.05 C
*38506060A Hi-Flo *3A-95/5060/60 490x592x600 F8 5 3.9 2250/180 2.1 0.05 C
*38506038A Hi-Flo *3A-95/5060/38 490x592x380 F8 5 2.4 1800/225 1.8 0.05 C
*38306060A Hi-Flo *3A-95/3060/60 287x592x600 F8 3 2.3 1350/170 1.5 0.03 C
*38306038A Hi-Flo *3A-95/3060/38 287x592x380 F8 3 1.5 1100/215 1.3 0.03 C
Other sizes are available on request - *3 denotes a 25mm header frame, if a 20mm header frame is required please specify *2.
32
Bag and Compact Filters, Class F5 to F9
Hi-Flo ® T-Series
Advantages
• Large surface area • Controlled media spacing
Pre-Filtration, Class G3 to F5
• Ultra compact (CMS)
• Low pressure drop • High dust holding capacity
D
IE
W
DI
VI
Holding frames: Front and side access housings and frames are available, Type 8, Type L, and
F
DU TI
Class F5 to F9
ALLY CER
FC Housings.
EFFICIENCY
GUARANTEE
H E PA / U L PA F i l t e r s , C l a s s
(WxHxD) EN 779:2002 pockets area m 2 drop m 3 /hr/Pa weight kg volume m 3
535023A1 Hi-Flo *TM6 592x592x380 F6 12 5.5 3400/90 2.3 0.05
H10 to U17
535024A1 Hi-Flo TN6 490x592x380 F6 10 4.5 2800/90 2.2 0.05
535022A1 Hi-Flo TO6 287x592x380 F6 6 2.7 1700/90 1.4 0.03
535023A2 Hi-Flo TM7 592x592x380 F7 12 5.5 3400/130 2.3 0.05
535024A2 Hi-Flo TN7 490x592x380 F7 10 4.5 2800/130 2.1 0.05
535022A2 Hi-Flo TO7 287x592x380 F7 6 2.7 1700/130 1.4 0.03
535023A3 Hi-Flo TM9 592x592x380 F8/9 12 5.5 3400/205 2.3 0.05
33
Bag and Compact Filters, Class F5 to F9
S-Flo W P Series
Advantages
• Extended surface multi-pocket • High efficiency
filter • Large surface area
• Comprehensive range of • Controlled media spacing
standard sizes (CMS)
• Unique pocket design
EN 779:2002 Recommended final pressure drop: 450 Pa (suggested economical change point 250 Pa).
IN
D
IE
DI
VI
D
ALLY CER
Holding frames: Front and side access housings and frames are available, Type 8, Type L, and
FC Housings.
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
*37506053PW S-Flo-W *Q7 490x592x534 F7 2800/75 8 5,2 2,4 0,05 E
*37306053PW S-Flo-W *R7 287x592x534 F7 1700/75 5 3,2 1,6 0,03 E
*38606053PW S-Flo-W *P8 592x592x534 F8 3400/95 10 6,5 2,7 0,05 E
*38506053PW S-Flo-W *Q8 490x592x534 F8 2800/95 8 5,2 2,4 0,05 E
*38306053PW S-Flo-W *R8 287x592x534 F8 1700/95 5 3,2 1,6 0,03 E
Other sizes are available on request - *Supplied with a 25mm header frame, if a 20mm header frame is required please specify *2.
34
Bag and Compact Filters, Class F5 to F9
S-Flo W U Series
Advantages
• Multi-pocket bag filter • Unique pocket design
Pre-Filtration, Class G3 to F5
• Comprehensive range of • Large surface area
standard sizes • Controlled media spacing
• Robust metal header frame (CMS)
EN 779:2002
Temperature: 70°C maximum in continuous service.
IN
Class F5 to F9
IE
DI
VI F
TI
W
DU
ALLY CER
D Holding frames: Front and side access housings and frames are available, Type 8, Type L, and
FC Housings.
H E PA / U L PA F i l t e r s , C l a s s
H10 to U17
Dimensions Filter classification Air flow/pressure drop Number of Media Unit weight Unit volume Energy
Reference Type Model
(WxHxD) mm EN 779:2002 m³/hr/Pa pockets area m 2 kg m3 Rating
35
Bag and Compact Filters, Class F5 to F9
S-Flo W A Series
Advantages
• Multi-pocket bag filter • Unique pocket design
• Comprehensive range of • Available in a range of
standard sizes efficiencies
• Robust metal header frame
EN 779:2002
Temperature: 70°C maximum in continuous service.
Holding frames: Front and side access housings and frames are available, Type 8, Type L, and
IN
D
IE
DI
VI
W
F
DU TI
ALLY CER
D
FC Housings.
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
*36606060AW S-Flo-W *A6 592x592x600 F6 3400/55 6 4,70 2,40 0,050
*36606038AW S-Flo-W *A6/38 592x592x380 F6 2550/40 6 2,90 2,00 0,050
*36506060AW S-Flo-W *B6 490x592x600 F6 2800/55 5 3,90 2,00 0,050
*36506038AW S-Flo-W *B6/38 490x592x380 F6 2100/40 5 2,40 1,80 0,050
*36306060AW S-Flo-W *C6 287x592x600 F6 1700/55 3 2,30 1,50 0,030
*36306038AW S-Flo-W *C6/38 287x592x380 F6 1275/40 3 1,50 1,30 0,030
*37606060AW S-Flo-W *A7 592x592x600 F7 2550/52 6 4,70 2,40 0,050
*37606038AW S-Flo-W *A7/38 592x592x380 F7 2550/80 6 2,90 2,00 0,050
*37506060AW S-Flo-W *B7 490x592x600 F7 2100/52 5 3,90 2,00 0,050
*37506038AW S-Flo-W *B7/38 490x592x380 F7 2100/80 5 2,40 1,80 0,050
*37306060AW S-Flo-W *C78 287x592x600 F7 1275/52 3 2,30 1,50 0,030
*37306038AW S-Flo-W *C7/38 287x592x380 F7 1275/80 3 1,50 1,30 0,030
*38606060AW S-Flo-W *A8 592x592x600 F8 3400/100 6 4,70 2,40 0,050
*38606038AW S-Flo-W *A8/38 592x592x380 F8 3400/195 6 2,90 2,00 0,050
*38506060AW S-Flo-W *B8 490x592x600 F8 2800/100 5 3,90 2,00 0,050
*38506038AW S-Flo-W *B8/38 490x592x380 F8 2800/195 5 2,40 1,80 0,050
*38306060AW S-Flo-W *C8 287x592x600 F8 1700/100 3 2,30 1,50 0,030
*38306038AW S-Flo-W *C8/38 287x592x380 F8 1700/195 3 1,50 1,30 0,030
Other sizes are available on request - *Supplied with a 25mm header frame, if a 20mm header frame is required please specificy *2.
36
Bag and Compact Filters, Class F5 to F9
Opakfil Green
Advantages
• Less frequent changes • Large surface area
Pre-Filtration, Class G3 to F5
• Long operating life • Certified performance
• Light and robust optimised for LCC
Class F5 to F9
IN
D
IE
Recommended final pressure drop: 450 Pa (suggested economical change point 350 Pa).
DI
W
VI F
DU TI
D
ALLY CER
H E PA / U L PA F i l t e r s , C l a s s
H10 to U17
EFFICIENCY
GUARANTEE
37
Bag and Compact Filters, Class F5 to F9
Advantages
• Large surface area • Ultra compact
• Savings in operating costs • High dust holding capacity
• 10 times more filtration surface • Less frequent changes
Application: Air conditioning or industrial processing systems and for mini air conditioning
systems, individual modules.
Type: High efficiency compact filter.
Frame: Galvanised steel.
Media: Glass fibre paper.
TIFICAT
Separator: Hot-melt beads.
ER
E
C
EN 779:2002
EN 779:2002 efficiency: F6, F7.
Opacimetric efficiency: 65, 85%.
IN
W
IE
DI
VI F
DU TI
ALLY CER
D
Eurovent 4/5 efficiency: EU6, EU7.
Recommended final pressure drop: Ecopleat: 350 Pa - Ecopleat MCTA: 250 Pa.
Temperature: 70°C maximum in continuous service.
EFFICIENCY
GUARANTEE
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
1020.80.02 ECOPLEAT Ecopleat F6 560x190x48 F6 1.8 715/65 1.5 0.01 D
1020.80.03 ECOPLEAT Ecopleat F6 255x480x48 F6 2.1 665/55 1.5 0.01 D
1020.80.04 ECOPLEAT Ecopleat F6 255x830x48 F6 3.6 1100/45 2 0.01 D
1020.80.05 ECOPLEAT Ecopleat F6 255x1130x48 F6 4.8 1570/50 3 0.01 D
1021.07.00 ECOPLEAT Ecopleat F7 287x592x48 F7 2.85 1500/175 2 0.01 B
1021.08.00 ECOPLEAT Ecopleat F7 592x592x48 F7 5.89 3000/160 3 0.02 B
1021.05.00 ECOPLEAT Ecopleat F7 305x610x48 F7 3.13 1700/175 2 0.01 B
1021.06.00 ECOPLEAT Ecopleat F7 610x610x48 F7 6.25 3400/175 3 0.02 B
1021.16.00 ECOPLEAT Ecopleat F7 610x610x98 F7 14.1 4000/120 4 0.04 B
1020.80.01 ECOPLEAT MCTA 352x225x48 F6 1.3 350/38 1 0.01 D
1020.80.10 ECOPLEAT MCTA 400x240x48 F6 1.6 340/25 1.2 0.01 D
1020.80.11 ECOPLEAT MCTA 470x240x48 F6 1.9 680/50 1.3 0.01 D
1020.80.12 ECOPLEAT MCTA 550x240x48 F6 2.2 680/42 1.4 0.01 D
Other dimensions available - Other models available, contact us - Also available in incinerable version: Ecopleat Green.
38
Bag and Compact Filters, Class F5 to F9
Riga-Flo
Advantages
• Range of standard sizes • High efficiency
Pre-Filtration, Class G3 to F5
• Rigid design concept • Suitable for turbulent airflow
Class F5 to F9
TIFICAT
ER
E
C
EN 779:2002
IN
D
IE
DI
VI F
TI
W
DU
ALLY CER
D
H E PA / U L PA F i l t e r s , C l a s s
EFFICIENCY
GUARANTEE
H10 to U17
Filter classification EN Media surface Air flow/presure drop at m 3 / Unit weight kg
Reference Type Model Dimensions (WxHxD) mm Unit volume m 3
779:2002 m2 h/Pa
060558-007 Riga Flo Riga Flo 10 594x594x292 F5 5.4 3420/65 7.70 0.11
060558-012 Riga Flo Riga Flo 10 492x594x292 F5 4.4 2790/65 5.77 0.11
060558-008 Riga Flo Riga Flo 10 289x594x292 F5 2.6 1710/65 4.55 0.06
078367-007 Riga Flo Riga Flo 10 594x594x152 F5 2.7 2070/55 3.42 0.06
078367-016 Riga Flo Riga Flo 10 492x594x152 F5 2.2 1710/55 2.57 0.06
078367-008 Riga Flo Riga Flo 10 289x594x152 F5 1.3 990/55 2.21 0.03
060558-001 Riga Flo Riga Flo 15 594x594x292 F6 5.4 3420/70 7.70 0.11
060558-009 Riga Flo Riga Flo 15 492x594x292 F6 4.4 2790/70 5.77 0.11
060558-004 Riga Flo Riga Flo 15 289x594x292 F6 2.6 1710/70 4.55 0.06
078367-001 Riga Flo Riga Flo 15 594x594x152 F6 2.7 2070/65 3.42 0.06
078367-013 Riga Flo Riga Flo 15 492x594x152 F6 2.2 1710/65 2.57 0.06
078367-004 Riga Flo Riga Flo 15 289x594x152 F6 1.3 990/65 2.21 0.03
060558-002 Riga Flo Riga Flo 100 594x594x292 F7 5.4 3420/90 7.70 0.11
060558-010 Riga Flo Riga Flo 100 492x594x292 F7 4.4 2790/90 5.77 0.11
060558-005 Riga Flo Riga Flo 100 289x594x292 F7 2.6 1710/90 4.55 0.06
Filter Frames and Housings
078367-002 Riga Flo Riga Flo 100 594x594x152 F7 2.7 2070/90 3.42 0.06
078367-014 Riga Flo Riga Flo 100 492x594x152 F7 2.2 1710/90 2.57 0.06
078367-005 Riga Flo Riga Flo 100 289x594x152 F7 1.3 990/90 2.21 0.03
060558-003 Riga Flo Riga Flo 200 594x594x292 F8 5.4 3420/130 7.70 0.11
060558-011 Riga Flo Riga Flo 200 492x594x292 F8 4.4 2790/130 5.77 0.11
060558-006 Riga Flo Riga Flo 200 289x594x292 F8 2.6 1710/130 4.55 0.06
078367-003 Riga Flo Riga Flo 200 594x594x152 F8 2.7 2070/175 3.42 0.06
078367-015 Riga Flo Riga Flo 200 492x594x152 F8 2.2 1710/175 2.57 0.06
078367-006 Riga Flo Riga Flo 200 289x594x152 F8 1.3 990/175 2.21 0.03
Other sizes are available on request - PH version also available (with header frame)
A i r F i l t e r Te c h n o l o g y
39
Bag and Compact Filters, Class F5 to F9
OpakAir
Advantages
• Large surface area • Less frequent changes
• Up to 6000 m 3 /hr air flow • Low pressure drop
Application: High air flow air conditioning and process air applications.
Type: High capacity compact filter.
Case: Galvanised steel.
Gasket: Half round EDPM.
Media: Glass fibre paper.
Separator: Hot-melt beads.
TIFICAT
ER
Sealant: Polyurethane.
E
C
EN 779:2002
EN 779:2002 efficiency: F8.
IN
D
IE
DI
VI F
W
DU TI
D
ALLY CER
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
40
Bag and Compact Filters, Class F5 to F9
Airopac ®
Advantages
• Low pressure drop • Large surface area
Pre-Filtration, Class G3 to F5
• Robust metal header frame • Rigid design concept
• High dust holding capacity
Class F5 to F9
Temperature: 70°C maximum in continuous service.
Mounting system: Front and side access housing and frames are available, type 8, type L and
FC housings.
EFFICIENCY
GUARANTEE
H E PA / U L PA F i l t e r s , C l a s s
Dimensions Air flow/nominal Media area Unit Unit Energy
Reference Type Model (WxHxD) mm pressure drop m³/h/Pa m2 weight kg volume m 3 Rating
H10 to U17
304215 Airopac-90 3GGM-24246-90 610x610x150 3600/105 12,3 6,8 0,06 B
304219 Airopac-90 3GGM-12246-90 305x610x150 1800/110 6,1 4,0 0,03 B
301732 Airopac-HF-90 3GGMHF-24245-90 592x592x135 3600/135 10,3 6,8 0,05 B
301739 Airopac-HF-90 3GGMHF-12245-90 287x592x135 1800/160 4,5 3,8 0,02 B
41
Bag and Compact Filters, Class F5 to F9
Notes
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
42
H E PA / U L PA F i l t e r s , C l a s s H 1 0 t o U 1 7
Pre-Filtration, Class G3 to F5
Filters for High Efficiency Filters for High Efficiency Filters for High Efficiency Filters for High Efficiency
Sofilair - H10 to H14 Sofilair Green Close Pleat - H13 Opakfil G Micretain - H10
Page 45 Page 46 Page 47 Page 48
H E PA / U L PA F i l t e r s , C l a s s
H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
HEPA/ULPA Panels
Megalam MD & MX e-PTFE -
U15
Page 57
A i r F i l t e r Te c h n o l o g y
43
HEPA / ULPA Filters, Class H 10 to U 1 7
EN1822
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
SOFILAIR and MEGALAM… what you can • It can also be used as part of the validation process
expect: 100% control of everything we ensuring regulatory compliance of your installation.
produce.
• Qualified personnel responsible for testing. In short EN 1822 means:
• Unique serial number for each filter.
• Individually certified filters
• Clear, unambiguous control procedures specifying test
• Tested using MPPS (Most Penetrating Particle Size)
conditions, target values and actual performance of
our filters. challenge.
• Explicit, standardised test procedures.
• Complete traceability of materials and operations.
• Full traceability of materials and test data.
• Equipment and systems certified by accredited
bodies. • NB: the filter grades EU13 etc, are incompatible with
• Tested performance verified by installation testing
EN 1822.
and validation.
44
H E PA / U L PA F i l t e r s , C l a s s H 1 0 t o U 1 7
Advantages
• High air flow rates, up to 5000 • New ergonomic handle to assist
Pre-Filtration, Class G3 to F5
m 3 /hr with filter changes
• Tested in accordance with • Low pressure drop
EN 1822
Application: Very high efficiency final filtration in air conditioning systems, housings and
diffusers.
Type: High air flow HEPA filter.
Frame: Galvanised steel.
Media: Glass fibre paper.
Separator: Hot-melt beads.
Class F5 to F9
W D EN 1822 efficiency: H10, H12, H13, and H14.
MPPS efficiency: H10:>85%, H12:>99.5%, H13:>99.95%, H14:> 99.995%.
Recommended final pressure drop: 600 Pa.
Maximum air flow rate: See table, use nominal values otherwise a reduction in efficiency may
occur.
Temperature: 80°C maximum in continuous service.
Mounting systems: Front and side access filter frames, FC Housings, terminal housings and
safe change systems.
H E PA / U L PA F i l t e r s , C l a s s
Dimensions Filter classification Media Air flow/preassure Unit Unit
Reference Type Model (WxHxD) mm EN 1822 area m 3 drop m 3 /h/Pa weight kg volume m 3
H10 to U17
1575.02.00 Sofilair H10 SFR-E-2000-H10 305x610x292 H10 14 2000/230 8 0,06
1573.02.00 Sofilair H10 SFR-E-4000-H10 610x610x292 H10 21 4000/230 13 0,11
1570.01.00 Sofilair H10 SFR-E-5000-H10 610x610x292 H10 35 5000/230 16,5 0,11
1585.01.00 Sofilair H12 SFR-E-1500-H12 305x610x292 H12 16 1500/250 8,5 0,06
1580.01.00 Sofilair H12 SFR-E-3400-H12 610x610x292 H12 33 3400/250 16,5 0,11
1580.02.00 Sofilair H12 SFR-E-4000-H12 610x610x292 H12 40 4000/250 16,5 0,11
45
HEPA / ULPA Filters, Class H 10 to U 1 7
Sofilair Green
Advantages
• Totally incinerable • New ergonomic handle to assist
• High air flow rates with filter changes
• Light weight construction • Corrosion resistant
Application: High efficiency final filtration in air conditioning systems, extraction from corrosive
or hazardous environments.
Type: High air flow incinerable HEPA filter.
Frame: ABS.
Media: Glass fibre paper.
Separator: Hot-melt beads.
Sealant: Polyurethane.
Gasket: One piece half round continuous gasket.
EN1822 EN 1822 efficiency: H10, H12, H13, H14.
W D MPPS efficiency: H10:>85%, H13:>99.95 & H14:>99.995%.
Recommended final pressure drop: 600 Pa.
Maximum air flow rate: See table, use nominal values otherwise a reduction in efficiency may
occur.
Temperature: 60°C maximum in continuous service.
Mounting systems: Front and side access filter frames. Terminal housings and safe change
systems.
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
1400/280
1565.81.02 Sofilair Green H14 SFRG-P-1400-H14 305x610x292 H14 15 6 0,06
1500/310*
3500/270
1560.82.06 Sofilair Green H14 SFRG-P-3500-H14 610x610x292 H14 38 12 0,11
4000/310*
46
H E PA / U L PA F i l t e r s , C l a s s H 1 0 t o U 1 7
Advantages
• Range of standard sizes • Very high efficiency
Pre-Filtration, Class G3 to F5
• Compact design concept
Application: Very high efficiency final filtration in air conditioning systems, housings, ducts and
diffusers.
Type: Close pleated very high efficiency filter.
Frame: Galvanised steel / MDF.
Gasket: Half round continuous expanded polyurethane.
Media: Pleated glass paper.
Separator: Hot melt beads.
Sealant: Polyurethane.
Class F5 to F9
D DOP efficiency ≈ 0.3 μm: ≥ 99.99%.
Recommended final pressure drop: 600 Pa.
Maximum flow rate: See table, use nominal values otherwise a reduction in efficiency may
occur.
Temperature: 70°C maximum in continuous service.
Mounting systems: FCB Housings, Ducts, Diffusers, CAMSAFE.
Dimensions Filter classification Air flow/pressure drop Media area Unit Unit
H E PA / U L PA F i l t e r s , C l a s s
Reference Type Model (WxHxD) mm EN 1822 m³/hr/Pa m2 weight kg volume m 3
229004A1 Steel case HEPA TREA-1000 610x610x292 H13 2700 / 250 23,5 13 0,13
H10 to U17
229002A1 Steel case HEPA TREA-450 305x610x292 H13 1350 / 250 11,7 7 0,07
231007A1 Steel case HEPA MXEA-600 610x610x150 H13 1625 / 250 13,4 12 0,07
231004A1 Steel case HEPA MXEA-220 305x610x150 H13 820 / 250 6,7 6 0,04
226001A1 MDF case HEPA TRSA-1000 610x610x292 H13 2450 / 250 21,4 13 0,13
226003A1 MDF case HEPA TRSA-450 305x610x292 H13 1160 / 250 10,1 7 0,07
225006A1 MDF case HEPA MXSA-600 610x610x150 H13 1475 / 250 12,1 12 0,07
225007A1 MDF case HEPA MXSA-220 305x610x150 H13 690 / 250 5,7 6
Alternative models, sizes and constructions are available.
47
HEPA / ULPA Filters, Class H 10 to U 1 7
Advantages
• Easy to install • Up to 4000 m 3 /hr air flow
• Incinerable
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
48
H E PA / U L PA F i l t e r s , C l a s s H 1 0 t o U 1 7
Advantages
• Less pressure drop • Longer operating life
Pre-Filtration, Class G3 to F5
• Quieter • Higher flow rate
Class F5 to F9
Less pressure loss More Flow
H E PA / U L PA F i l t e r s , C l a s s
H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
49
HEPA / ULPA Filters, Class H 10 to U 1 7
H E PA / U L PA P a n e l s
Advantages
• Low pressure drop • Longer operating life
• Quiet: LW = 35dB • Individually scanned in
• Higher flow rate accordance with EN 1822
Application: Final or return filtration for clean rooms with turbulent flow.
Type: HEPA filtering panel with seal for mechanical clamping systems.
Frame: Extruded and anodised aluminium.
Gasket: Half round continuous expanded polyurethane.
Media: Glass fibre paper.
Separator: Hot-melt beads.
EN1822
Sealant: Polyurethane.
W D
Grid: Mild steel painted grille upstream and downstream.
EN 1822 efficiency: H14.
MPPS efficiency: ≥ 99.995%.
Recommended final pressure drop: 600 Pa.
Maximum flow rate: see table, use nominal values otherwise a reduction in efficiency may
occur.
Temperature: 70°C maximum in continuous service.
Test: 100% individually scanned to EN 1822.
Mounting system: Mechanical clamping structure, Terminal housing.
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
3444.00.30 MEGALAM MGA 6P6 610x610x110 H14 19.8 600/70 2000/220 8.0 0.04
3444.00.40 MEGALAM MGA 9P6 915x610x110 H14 27.0 900/70 3000/220 10.0 0.06
3444.00.50 MEGALAM MGA 12P6 1220x610x110 H14 36.3 1200/70 4000/220 13.0 0.08
Other dimensions available on request - Also available with laminator
50
H E PA / U L PA F i l t e r s , C l a s s H 1 0 t o U 1 7
Advantages
• Low pressure drop • Guaranteed performance
Pre-Filtration, Class G3 to F5
• Protection via 2 grids
Application: Final or return filtration for clean rooms with turbulent flow.
Type: HEPA filtering panel with seal for mechanical clamping mounting systems.
Frame: Extruded and anodised aluminium.
Gasket: Half round continuous expanded polyurethane.
Media: Glass fibre paper.
Separator: Hot-melt beads.
Sealant: Polyurethane.
Grid: Mild steel painted grille upstream and downstream.
Class F5 to F9
D DOP efficiency: H10: ≥ 95%, H14: ≥ 99.999%.
Recommended final pressure drop: 600 Pa.
Maximum flow rate: See table, use nominal values otherwise a reduction in efficiency may
occur.
Temperature: 70°C maximum in continuous service.
Test: : 100% individually scanned to EN 1822.
Mounting system: Mechanical clamping structure, Terminal housings.
H E PA / U L PA F i l t e r s , C l a s s
Filter Air flow / pressure Unit Unit
Dimensions Media
Reference Type Model classification EN drop at 0.45 m/s weight volume
(WxHxD) mm area m 2
1822 m 3 /h/Pa kg m3
H10 to U17
3401.61.11 MEGALAM MDM 3P6 305x610x66 H10 4.6 300/70 2.0 0.02
3401.62.08 MEGALAM MDM 6P6 610x610x66 H10 9.3 600/70 4.0 0.03
3401.63.01 MEGALAM MDM 9P6 915x610x66 H10 14.0 900/70 6.0 0.05
3401.64.07 MEGALAM MDM 12P6 1220x610x66 H10 18.5 1200/70 9.0 0.07
3423.00.10 MEGALAM MDA 3P3 305x305x66 H14 2.4 150/140 1.0 0.01
3423.00.20 MEGALAM MDA 3P6 305x610x66 H14 4.8 300/130 3.0 0.02
3423.00.30 MEGALAM MDA 6P6 610x610x66 H14 10.0 600/120 5.0 0.03
3423.00.90 MEGALAM MDA 7P6 762x610x66 H14 12.3 750/120 5.0 0.04
3423.00.40 MEGALAM MDA 9P6 915x610x66 H14 14.8 900/120 6.0 0.05
3423.00.50 MEGALAM MDA 12P6 1220x610x66 H14 19.8 1200/120 9.0 0.07
3423.00.60 MEGALAM MDA 15P6 1525x610x66 H14 24.9 1500/120 10.0 0.07
3423.01.00 MEGALAM MDA 9P7 915x762x66 H14 18.6 1125/120 7.5 0.06
3423.01.10 MEGALAM MDA 12P7 1220x762x66 H14 24.9 1500/120 10.0 0.07
3423.01.20 MEGALAM MDA 15P7 1525x762x66 H14 31.0 1875/120 12.5 0.09
Filter Frames and Housings
3423.01.30 MEGALAM MDA 18P7 1830x762x66 H14 37.2 2250/120 12.5 0.12
3423.01.40 MEGALAM MDA 3P9 305x915x66 H14 7.4 450/120 3.0 0.03
3423.01.50 MEGALAM MDA 9P9 915x915x66 H14 22.3 1350/120 9.0 0.06
3423.01.60 MEGALAM MDA 12P9 1220x915x66 H14 30.0 1800/120 12.0 0.08
Other dimensions available on request
A i r F i l t e r Te c h n o l o g y
51
HEPA / ULPA Filters, Class H 10 to U 1 7
H E PA / U L PA P a n e l s
Advantages
• Guaranteed performance • Protection via 2 grids
• 100% individual scanning test • Very high efficiency
according to standard EN 1822
Application: Final or return filtration for clean rooms with turbulent flow.
Type: ULPA filtering panel with seal for mechanical clamping systems.
Frame: Extruded and anodised aluminium.
Gasket: Half round continuous expanded polyurethane.
Media: Glass fibre paper.
Separator: Hot-melt beads.
Sealant: Polyurethane.
Grid: Mild steel painted grille upstream and downstream.
EN1822 EN 1822 efficiency: U15.
W D MPPS efficiency: ≥ 99.9995%.
Recommended final pressure drop: 600 Pa.
Maximum flow rate: See table, use nominal values otherwise a reduction in efficiency may
occur.
Temperature: 70°C maximum in continuous service.
Test: 100% individually scanned to EN 1822.
Mounting system: Mechanical clamping structure, Terminal housings.
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
3418.00.50 MEGALAM MDGS 12P6 1220x610x66 U15 22,5 1200/140 8.0 0,07
3418.00.60 MEGALAM MDGS 15P6 1525x610x66 U15 28,3 1500/140 10.0 0,07
3418.00.80 MEGALAM MDGS 3P7 305x762x66 U15 7 375/140 2.5 0,02
3418.01.00 MEGALAM MDGS 9P7 915x762x66 U15 21,1 1125/140 7.5 0,06
3418.01.10 MEGALAM MDGS 12P7 1220x762x66 U15 28,3 1500/140 10.0 0,07
3418.01.20 MEGALAM MDGS 15P7 1525x762x66 U15 35,3 1875/140 12.5 0,09
3418.01.40 MEGALAM MDGS 3P9 305x915x66 U15 8,3 450/140 3.0 0,03
3418.01.50 MEGALAM MDGS 9P9 915x915x66 U15 25,3 1350/140 9.0 0,06
3418.01.60 MEGALAM MDGS 12P9 1220x915x66 U15 33,9 1800/140 12.0 0,08
52
H E PA / U L PA F i l t e r s , C l a s s H 1 0 t o U 1 7
Advantages
• Laminarity better than +/- 20% • Integrated laminator screen
Pre-Filtration, Class G3 to F5
• 100% individual scanning test • ULPA U15 and U16
according to standard EN 1822
Application: Final filtration for clean rooms, clean devices and units with laminar flow.
Type: ULPA filtering panel with laminator and gasket for mechanical clamping systems.
Frame: Extruded and anodised aluminium.
Gasket: Half round continuous expanded polyurethane.
Media: Glass fibre paper.
Separator: Hot-melt beads.
Sealant: Polyurethane.
Class F5 to F9
D EN 1822 efficiency: U15 / U16.
MPPS efficiency: U15: ≥99.9995%, U16: ≥99.99995%.
Recommended final pressure drop: 600 Pa.
Maximum flow rate: See table, use nominal values otherwise a reduction in efficiency may
occur.
Temperature: 70°C maximum in continuous service.
Test: 100% individually scanned to EN 1822.
Mounting system: Mechanical clamping structure, Terminal housings.
H E PA / U L PA F i l t e r s , C l a s s
Filter Unit
Dimensions Media Air flow/pressure Unit weight volume
Reference Type Model classification EN area
H10 to U17
(WxHxD) mm m² drop m³/h/Pa kg
1822 m3
3449.20.40 MEGALAM MDLGS 9P6-01 915x610x66 U15 16.9 900/150 6.0 0.05
3449.00.40 MEGALAM MDLGS 9P6-10 915x610x66 U15 16.9 900/150 6.0 0.05
3449.20.50 MEGALAM MDLGS 12P6-01 1220x610x66 U15 22.5 1200/150 8.0 0.07
3449.00.50 MEGALAM MDLGS 12P6-10 1220x610x66 U15 22.5 1200/150 8.0 0.07
3450.20.40 MEGALAM MDLSGS 9P6-01 915x610x66 U16 18.4 900/165 6.0 0.05
3450.00.40 MEGALAM MDLSGS 9P6-10 915x610x66 U16 18.4 900/165 6.0 0.05
3450.00.50 MEGALAM MDLSGS 12P6-01 1220x610x66 U16 24.5 1200/165 8.0 0.07
3450.20.50 MEGALAM MDLSGS 12P6-01 1220x610x66 U16 24.5 1200/165 8.0 0.07
3425.20.30 MEGALAM MXLGS 6P6-01 610x610x90 U15 15.4 600/120 5.6 0.05
3425.00.30 MEGALAM MXLGS 6P6-10 610x610x90 U15 15.4 600/120 5.6 0.05
Other dimensions available on request
Filter Frames and Housings
A i r F i l t e r Te c h n o l o g y
53
HEPA / ULPA Filters, Class H 10 to U 1 7
H E PA / U L PA P a n e l s
Advantages
• H14 compact filter-diffuser for • Quiet: LW = 35 dB
clean room • Laminarity +/- 20%
• Ready to install
Air flow/nominal
Dimensions (WxHxD) Filter classification media Unit Unit volume
Reference Type Model pressure drop
mm EN 1822 area m 2 m³/h/Pa weight kg m3
5970.00.21 Silent Hood MDSHA RF1 300x600x116/250 H14 4.2 300/140 10 0.03
5975.00.31 Silent Hood MDSHA RF1 600x600x116/315 H14 9.2 600/140 13 0.06
5975.00.41 Silent Hood MDSHA RF 905x600x116/335 H14 14 900/140 16 0.09
5975.00.51 Silent Hood MDSHA RF1 1210x600x116/315 H14 19 1200/140 19 0.13
5975.00.20 Silent Hood MDSHA RF1 305x610x116/250 H14 4.3 300/140 10 0.03
5975.00.30 Silent Hood MDSHA RF1 610x610x116/315 H14 9.4 600/140 13 0.06
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
5975.00.40 Silent Hood MDSHA RF 915x610x116/315 H14 14.6 900/140 16 0.09
5975.00.50 Silent Hood MDSHA RF 1220x610x116/315 H14 19.5 1200/140 19 0.13
Other dimensions available on request. Available in other grades and with a laminator
54
H E PA / U L PA F i l t e r s , C l a s s H 1 0 t o U 1 7
Advantages
• Leaktightness by means of gel • Can be assembled without
Pre-Filtration, Class G3 to F5
• 100% individual control clamping
Class F5 to F9
D Temperature: 70°C maximum in continuous service.
Test: 100% individually scanned in accordance with EN 1822.
H E PA / U L PA F i l t e r s , C l a s s
3413.08.89 MEGALAM MDA U H14 305x610x78 4.8 300/120 300/200 0.02 4.0
3413.08.79 MEGALAM MDA U H14 610x610x78 10.0 600/120 1000/200 0.03 6.0
3413.08.87 MEGALAM MDA U H14 915x610x78 14.8 900/120 1500/200 0.05 8.0
H10 to U17
3413.08.90 MEGALAM MDA U H14 1220x610x78 19.8 1200/120 2000/200 0.06 11.0
3413.08.97 MEGALAM MDA U H14 305x762x78 6.1 375/120 625/200 0.02 4.5
3413.08.98 MEGALAM MDA U H14 915x762x78 18.6 1125/120 1875/200 0.05 9.0
3413.08.91 MEGALAM MDA U H14 1220x762x78 24.9 1500/120 2500/200 0.07 13.0
3413.08.88 MEGALAM MDA U H14 915x915x78 22.3 1350/120 2250/200 0.06 12.0
3413.08.95 MEGALAM MDA U H14 1220x915x78 29.0 1800/120 3000/200 0.08 15.0
55
HEPA / ULPA Filters, Class H 10 to U 1 7
H E PA / U L PA P a n e l s
Advantages
• Compact design • 100% individually scann tested
• Secure protection of the filter in accordance with EN 1822
media • Laminar air flow distribution
Application: Gel seal filter for terminal housings and laminar flow environments.
Type: HEPA/ULPA filter with gel seal.
Frame: Extruded anodised aluminium.
Media: Glass fibre paper.
Separator: Hot-melt beads.
Sealant: Polyurethane.
Gasket: PU Gel.
EN1822
W EN 1822 efficiency: H14 and U15.
D
MPPS efficiency: H14 = 99.995%, U15 = 99.9995%.
Recommended final pressure drop: 600 Pa.
Maximum air flow rate: See table, use nominal values otherwise a reduction in efficiency may
occur.
Temperature: 70°C maximum in continuous service.
Test: 100% individually scanned in accordance with EN 1822.
Mounting systems: Ceiling mounted grid systems and terminal housings.
Dimensions Media
Filter classification area Air flow/pressure Unit weight
Reference Type Model (WxHxD) Unit volume m 3
mm
EN 1822
m2 drop m 3 /h/Pa kg
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
3471.x1.10 MEGALAM MDT14 U-1220x762x71-2G 1220x762x71 H14 24,9 1500/120 10 0,07
3471.x1.50 MEGALAM MDT14 U-915x915x71-2G 915x915x71 H14 22,3 1350/120 9 0,06
3471.x1.60 MEGALAM MDT14 U-1220x915x71-2G 1220x915x71 H14 30 1800/120 12 0,08
3472.x0.20 MEGALAM MDT15 U-305x610x71-2G 305x610x71 U15 5,5 300/140 2 0,017
3472.x0.30 MEGALAM MDT15 U-610x610x71-2G 610x610x71 U15 11,2 600/140 4 0,034
3472.x0.90 MEGALAM MDT15 U-762x610x71-2G 762X610X71 U15 14 750/140 5 0,042
3472.x0.40 MEGALAM MDT15 U-915x610x71-2G 915x610x71 U15 16,9 900/140 6 0,051
3472.x0.50 MEGALAM MDT15 U-1220x610x71-2G 1220x610x71 U15 22,5 1200/140 8 0,068
3472.x0.80 MEGALAM MDT15 U-305x762x71-2G 305x762x71 U15 7 375/140 2,5 0,021
3472.x1.00 MEGALAM MDT15 U-915x762x71-2G 915x762x71 U15 21,1 1125/140 7,5 0,064
3472.x1.10 MEGALAM MDT15 U-1220x762x71-2G 1220x762x71 U15 28,3 1500/140 10 0,069
3472.x1.50 MEGALAM MDT15 U-915x915x71-2G 915x915x71 U15 25,3 1200/140 9 0,062
Please Note:
Seal Position "01" : x = 2
Seal Position "10" : x = 3
Other dimensions available on request
56
H E PA / U L PA F i l t e r s , C l a s s H 1 0 t o U 1 7
Advantages
• Very high efficiency • Chemical resistance
Pre-Filtration, Class G3 to F5
• High mechanical strength • No outgassing
Application: Very high efficiency final filter for clean environments and LAF benches.
Type: ULPA filter.
Frame: Extruded anodised aluminium.
Media: e PTFE (Teflon).
Separator: Hot-melt beads.
Sealant: Polyurethane.
Gasket: Half round continuous expanded polyurethane.
EN 1822 efficiency: U15
Class F5 to F9
D occur.
Temperature: 70°C maximum in continuous service.
Test: 100% individually scanned in accordance with EN 1822.
Mounting system: Ceiling mounted grid systems, terminal housings and clean devices.
H E PA / U L PA F i l t e r s , C l a s s
1645020Z MD15/PTFE-305×610 U15 305x610x66 4,80 300/105 0,017 2,00
1645050B MD15/PTFE-610×610 U15 610x610x66 9,70 605/100 0,034 4,00
1645150 MD15/PTFE-1220×610 U15 1220x610x66 19,50 1205/100 0,068 8,00
H10 to U17
164550P1 MD15/PTFE-1220×915 U15 1220x915x66 29,20 1810/100 0,083 12,00
57
HEPA / ULPA Filters, Class H 10 to U 1 7
Notes
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
58
Carbon and Chemical Filters
Pre-Filtration, Class G3 to F5
Compact 2 in 1 solution Compact 2 in 1 solution Compact Carbon Filter Carbon Cylinders
CityFlo CityCarb ® CitySorb Camcarb Green
Page 62 Page 63 Page 64 Page 65
H E PA / U L PA F i l t e r s , C l a s s
Page 67
H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
59
Carbon and Chemical Filters
I n d o o r a i r q u a l i t y, E N 1 3 7 7 9
The industrialised world pollution does not pass us by. It takes numerous different forms, for
example vehicle exhaust gas, factory chimneys, the dust raised by car
The industrialised world has changed immeasurably over the past 50 traffic and cigarette smoke. It has been known for some time that
years. One very real difference is that the air that we breathe is more exposure to pollution has an impact on human beings. The common
heavily, and more diversely, polluted. Although there are natural sources symptoms are headaches, watering eyes and lower performance at
of pollution, the main concern is pollution caused by human activity. work. Such symptoms are traditionally referred to as Sick Building
Tens of thousands of synthetic chemicals (which do not exist in any Syndrome or similar terms.
natural state) are now manufactured at an estimated rate of more than a
billion tons per year. These chemicals are released into the atmosphere
when they are produced, and when they are used they can travel great
distances. They inevitably form part of our lives. Our lifestyles (work and
leisure) mean that we spend more and more time inside buildings. The
fact that buildings have to be ventilated means that we are increasingly
exposed to particulate and gas pollution from the outdoor air.
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
Recommendations in EN 13779 for air filters
IAQ
Outdoor air quality Indoor Air Quality
IDA 1 (High) IDA 2 (Medium) IDA 3 (Moderate) IDA 4 (Low)
ODA 1 F9 F8 F7 F6
ODA 2 F7 / F9 F6 / F8 F6 / F7 G4 / F6
ODA 3 F7 / F9 F8 F7 F6
ODA 4 F7 / F9 F6 / F8 F6 / F7 G4 / F6
ODA 5 F6 / GF / F9 F6 / GF / F9 F6 / F7 G4 / F6
Table refering to appendix "A3. Use of Air Filters" in The European Standard EN 13779.
60
Carbon and Chemical Filters
Key:
4. A very high level of adsorption, in the order of 20 - 40% by weight of
dry carbon.
3. Good index with a capacity of 10 - 20%.
2. Mediocre index that may require a particularly long contact time,
Pre-Filtration, Class G3 to F5
requires case by case study.
1. Practically no adsorption, another solution must be sought.
Class F5 to F9
3 Acids 4 Chloronitropropane 4 Ethyl silicate 3 Methyl acetate 4 Petrol
3 Acrolein 4 Chloropicrin 4 Eucalyptol 4 Methyl acrylate 4 Phenol
4 Acrylic acid 4 Chloroprene 4 Faecal odours 3 Methyl alcohol 3 Phosgene
4 Acrylonitrile 3 Cigarette smells 3 Farmyard smells 3 Methyl bromide 4 Plastics
4 Adhesives 4 Cleaning solvents 4 Fertiliser 4 Methyl butyl ketone 2 Propane
4 Alcohol 3 Cooking smells 3 Film developing 3 Methyl chloride 4 Propanol
4 Amines 4 Creosote 2 Fish odours 4 Methylcyclohexane 2 Propylene
H E PA / U L PA F i l t e r s , C l a s s
2 Ammonia 4 Cresol 4 Floral odours 4 Methylcyclohexanol 4 Propyl mercaptan
2 Amyl acetate 4 Cyclohexane 2 Formaldehyde 4 Méthylcyclohexanone 4 Resins
H10 to U17
4 Amyl alcohol 4 Cyclohexanol 3 Formic acid 4 Methylene chloride 4 Rubber
4 Amyl ether 4 Cyclohexanone 3 Freon 3 Methyl ether 2 Slaughterhouse
3 Anaesthetics 4 Cyclohexene 4 Gangrene smell 4 Methyl ethyl ketone 3 Soap
4 Aniline 4 Deodorants 4 Garlic 4 Methyl isobutyl ketone 3 Solvents
4 Animal carcases 4 Detergents 4 Heptane 4 Methyl mercaptan 4 Styrene monomer
3 Animal odours 4 Dibromoethane 4 Heptylene 4 Monochlorobenzene 2 Sulphur components
4 Antiseptics 4 Dichlorobenzene 3 Hexane 4 Naphtha (coal tar) 2 Sulphur dioxide
61
Carbon and Chemical Filters
Compact 2 in 1 solution
CityFlo
Advantages
• Double action: particle and • Ideal for filtering most low
odour filtration concentration interior and
• Range of standard sizes exterior pollutants
• Can be used to upgrade existing • Robust metal header frame
installations • Compact “2 in 1” solution
VI F
TI
W
DU
ALLY CER
D
Holding frames: Front and side access holding frames are available: Type 8, Type L and FC
Housings.
Filter Unit
Dimensions Number of Carbon Air flow/pressure Unit Energy
Reference Type classification EN
(WxHxD) mm pockets mass kg drop m³/hr/Pa weight kg volume m 3 rating
779:2002
604001 CITYFLO 592x592x534 F7 10 2 3400/140 6 1,2 B
604002 CITYFLO 287x592x534 F7 5 1 1700/145 3,5 0,6 B
604003 CITYFLO 490x592x537 F7 8 1.5 2550/140 4.6 0.9 B
Ultimate solution
City-Flo is the ultimate solution when a high performance bag filter and a high performance odour removal filter are needed in the same encapsulated
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
space. The filter can be easily fitted into new or existing standard filter frames. High performance Camfil Farr glass fibre media is now combined with an
exclusive broad spectrum carbon media that utilises the benefits of RAD (Rapid Adsorption Dynamics) to remove a wide range of VOCs and odours.
Service life
The filter can be replaced when pressure loss exceeds the maximum allowed value for the ventilation system or after a maximum of one year.
Maintenance
Following good practice for all filters, used City-Flo filters should be bagged immediately after removal from the unit and disposed of by the appropriate
route.
62
Carbon and Chemical Filters
CityCarb ®
Advantages
• Compact “2 in 1” solution • 100% incinerable
Pre-Filtration, Class G3 to F5
• Ideal for filtering most low • Can be used to upgrade existing
concentration interior and installations
exterior pollutants • Double action: particle and
• Range of standard sizes odour filtration
Application: High efficiency particle filtration for deodorisation and purification of gas
pollutants, used for filtration in offices, airports and industrial workshops.
Type: High efficiency, activated carbon, incinerable filter.
Frame: Polypropylene.
Media: Synthetic fibre.
Class F5 to F9
Mounting system: "Camfil universal frame" frames in kit form, FC type housings.
H E PA / U L PA F i l t e r s , C l a s s
5716522 CITYCARB OPKCC-242412-85-0 592x592x290 F7 3 RAD 3400/120 7.5 0.11
5716532 CITYCARB OPKCC-242012-85-0 592x490x290 F7 2.5 RAD 2800/120 6.1 0.09
H10 to U17
5716542 CITYCARB OPKCC-241212-85-0 592x287x290 F7 1.5 RAD 1700/120 3.8 0.05
Citycarb has been specifically designed to easily improve the quality of indoor air due to
its "2 in 1" concept:
1. Highly effective filtration: Classed as F7 according to EN 779:2002, it stops 85% of 1 micron particles and meets the recommendations of UNICLIMA
and EUROVENT 12/1-92.
2. Adsorption of odours and pollution: This specifically designed product can provide efficiencies as high as 99% for Sulphur Dioxide, the main pollutant
63
Carbon and Chemical Filters
CitySorb
Advantages
• Range of standard sizes • High efficiency
• Rigid design concept • Large air flow capacity
Citysorb is a high-efficiency compact molecular filter for addressing IAQ issues in public and commercial buildings. This filter satisfies
demands to tackle nuisance odours and provide occupants with the highest indoor air quality as specified in the European Standard EN
13779. The material selection and construction method ensures that Citysorb is a clean, light filter that is both quick and easy to
maintain.
Also available, Citysorb Acid, for more efficient treatment of specific acid molecules.
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
Temperature 23º C
efficiency %
Humidity 50%
Concentration 80ppm
Airflow 3400 m3/h
Citysorb dP. 91 Pa
adsorbed toluene
64
Carbon and Chemical Filters
Camcarb Green
Advantages
• Completely incinerable • Conical inlet
Pre-Filtration, Class G3 to F5
• Low pressure drop • Rapid bayonet fitting system
• Reduced weight • Corrosion resistant
• Two integral moulded TPE • High performance
gaskets
Application: Adsorption of odours, VOC’s and / or low toxicity gases for airports, museums,
kitchens, hospitals or clean room industry.
Type: Cylindrical activated carbon cartridge in ABS and HDPE.
Temperature: 40°C maximum in continuous service.
Mounting System: Camcarb mounting frame, FC-CC housings.
Class F5 to F9
impregnated activated carbon, adsorption of non-organic gases.
Media: Coconut shell carbon CM05.
H E PA / U L PA F i l t e r s , C l a s s
571760 Camcarb Green Cylinder3500 147x93x600 26 3,1 CM 05 100/30 3,7
* Based on a contact time of 0.2 sec. Alternative models are also available.
H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
65
Carbon and Chemical Filters
Carbon Cylinders
Advantages
• Modular design adaptable for • Rapid fitting system via
all types of installations bayonet fitting
• Reduced weight • Quick and easy service
W D
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
66
Carbon and Chemical Filters
Camsure
Advantages
• Range of standard and non • Clean, dust free construction
Pre-Filtration, Class G3 to F5
standard sizes • Suitable for a wide range of air
• High performance volumes
Class F5 to F9
mm
CPB60060030NOM Bonded Carbon Panel 600x600x30 324/160 6.0 0.012
CPB60030030NOM Bonded Carbon Panel 600x300x30 160/160 3.0 0.006
H E PA / U L PA F i l t e r s , C l a s s
Above are sample sizes, filters are available in a comprehensive range of sizes, please specify.
Also available with stainless steel case.
H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
67
Housings, frames & special applications
Filter Holding Frames Filter Holding Frames Filter Housing Filter Housing
Absolute Filter Holding Frame Type 8 - Filter Holding Frame FCB-P FCBS-HF
Page 70 Page 71 Page 72 Page 73
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
Terminal Filter Housings Filter Containment Filters for High Filters for High
Pharmaseal Systems Temperature Temperature
Page 78 Camsafe Termikfil 2000 Absolute® 1FRK
Page 79 Page 80 Page 81
Filters for Painting Booths Filters for Painting Booths Filters for Painting Booths Filters for Painting Booths
Paint Extract Filters Airopac® HT-HF Panolair SSI - Micretain H10 CDM Media
Page 82 Page 83 Page 84 Page 85
68
Housings, frames & special applications
H E PA / U L PA F i l t e r s , C l a s s
H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
69
Housings, frames & special applications
Advantages
• Modular design adaptable for • Pre drilled for easy assembly
all types of installations • Filter holding clips can be
• Location dimples in frame easily replaced as required
ensure correct filter fitting
Application: Mounting very high efficiency filters in air conditioning units and systems.
Type: Front access filter holding frame.
Construction: Galvanised steel or stainless steel.
Filter Types: Absolute and Micretain very high efficiency filters.
Filter fixing: Using 4 corner mounted clamps.
W D
Exterior dimensions
Reference Type (WxHxD) mm Filter dimension (WxHxD) mm Unit weight kg Unit volume m 3
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
70
Housings, frames & special applications
Advantages
• Robust rigid construction • Modular design adaptable for
Pre-Filtration, Class G3 to F5
• Pre drilled for easy assembly all types of installations
• Filter holding clips can be • Location dimples in frame
easily replaced as required ensure correct filter fitting
Class F5 to F9
Reference Type Model Exterior dimensions (WxH) mm Unit weight kg Unit volume m 3
079473-801 Type 8 610x610 610x610x68 2,4 0,04
079473-007 Type 8 508x610 508x610x68 2,2 0,03
079473-002 Type 8 508x508 508x508x68 2,0 0,03
079473-004 Type 8 305x610 305x610x68 1,8 0,02
H E PA / U L PA F i l t e r s , C l a s s
Other materials available on request other dimensions and arrangements available on request.
H10 to U17
Fixing Clips
Order 4 clips per frame, other materials available on request, clips to suit alternative or combination filters, available on request.
71
Housings, frames & special applications
Filter Housing
FCB-P
Advantages
• Easy to Install • Gasket to seal between door
• Modular construction and filter housing
• No tools needed to change • Easy servicing
filters • Stable and secure design
W D
Exterior dimensions Interior dimensions Number of filters Number of filters Unit volume
Reference Type Model Unit weight kg
(WxHxD) mm (WxH) mm 592x592 mm 287x592 mm m3
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
604001070 FCB-P 1020 10 20 704×1360×202 614×1230 2 - 0.21 17
604001080 FCB-P 1025 10 25 704×1670×202 614×1540 2 1 0.26 21.5
604001090 FCB-P 1030 10 30 704×1975×202 614×1845 3 - 0.31 25
604001100 FCB-P 1510 15 10 1013×744×202 923×614 1 1 0.18 13.5
604001110 FCB-P 1520 15 20 1013×1360×202 923×1230 2 2 0.31 23
604001120 FCB-P 1530 15 30 1013×1975×202 923×1845 3 3 0.44 32.5
604001130 FCB-P 2010 20 10 1318×744×202 1228×614 2 - 0.22 15
604001140 FCB-P 2015 20 15 1318×1055×202 1228×925 2 2 0.31 25
604001150 FCB-P 2020 20 20 1318×1360×202 1228×1228 4 - 0.4 26.5
604001160 FCB-P 2025 20 25 1318×1670×202 1228×1540 4 2 0.49 35
604001170 FCB-P 2030 20 30 1318×1975×202 1228×1845 6 - 0.58 37
604001180 FCB-P 2510 25 10 1677×744×500 1537×614 2 0.28 19
604001190 FCB-P 2520 25 20 1677×1360×500 1537×1230 4 2 0.51 32.5
604001200 FCB-P 2530 25 30 1677×1975×500 1537×1845 6 3 0.74 46
604001210 FCB-P 3010 30 10 1982×744×500 1842×614 3 - 0.33 21.5
604001220 FCB-P 3015 30 15 1982×1055×500 1842×925 3 3 0.46 32.5
604001230 FCB-P 3020 30 20 1982×1360×500 1842×1230 6 - 0.6 36
604001240 FCB-P 3025 30 25 1982×1670×500 1842×1540 6 3 0.73 47.5
604001250 FCB-P 3030 3030 1982×1975×500 1842×1842 9 - 0.87 50.5
Other dimensions and arrangements available on request
72
Housings, frames & special applications
FCBS-HF
Advantages
• Easy to Install • Gasket to seal between door
Pre-Filtration, Class G3 to F5
• Modular construction and filter housing
• No tools needed to change • Easy servicing
filters • Stable and secure design
Number of Number of
Exterior dimensions Interior dimensions filters Unit Unit
H E PA / U L PA F i l t e r s , C l a s s
Reference Type Model 592x592 filters 287x592 volume
(WxHxD) mm (WxH) mm m³ weight kg
mm mm
613002020 FCBS-HF 0510 05 10 399×744×500 309×614 _ 1 0.15 18
H10 to U17
613002040 FCBS-HF 1005 10 05 704×439×500 614×309 - 1 0.16 18
613002050 FCBS-HF 1010 10 10 704×744×500 614×614 1 - 0.27 24
613002060 FCBS-HF 1015 10 15 704×1055×500 614×925 1 1 0.38 38
613002070 FCBS-HF 1020 10 20 704×1360×500 614×1230 2 - 0.49 42
613002080 FCBS-HF 1025 10 25 704×1670×500 614×1540 2 1 0.6 54
613002090 FCBS-HF 1030 10 30 704×1975×500 614×1845 3 - 0.71 62
73
Housings, frames & special applications
Filter Housing
FCBS-A
Advantages
• Easy to Install • Gasket to seal between door
• Modular construction and filter housing
• No tools needed to change • Easy servicing
filters • Stable and secure design
W D
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
605003580 FCBS-A 1025 10 25 704×1670×500 614×1540 2 0,6 59
605003590 FCBS-A 1030 10 30 704×1975×500 614×1845 3 - 0.71 68
605003600 FCBS-A 1510 15 10 1013×744×500 923×614 1 0.39 37
605003610 FCBS-A 1520 15 20 1013×1360×500 923×1230 2 2 0,7 62
605003620 FCBS-A 1530 15 30 1013×1975×500 923×1845 3 3 1.03 88
605003630 FCBS-A 2010 20 10 1318×744×500 1228×614 2 - 0,5 42
605003640 FCBS-A 2015 20 15 1318×1055×500 1228×925 2 2 0.71 68
605003650 FCBS-A 2020 20 20 1318×1360×500 1228×1228 4 - 0.92 72
605003660 FCBS-A 2025 20 25 1318×1670×500 1228×1540 4 2 1.13 95
605003670 FCBS-A 2030 20 30 1318×1975×500 1228×1845 6 - 1.33 101
605003680 FCBS-A 2510 25 10 1677×744×500 1537×614 2 1 0.64 51
605003690 FCBS-A 2520 25 20 1677×1360×500 1537×1230 4 2 1.17 89
605003700 FCBS-A 2530 25 30 1677×1975×500 1537×1845 6 3 1.7 126
605003710 FCBS-A 3010 30 10 1982×744×500 1842×614 3 - 0.76 59
605003720 FCBS-A 3015 30 15 1982×1055×500 1842×925 3 3 1.07 89
605003730 FCBS-A 3020 30 20 1982×1360×500 1842×1230 6 - 1.38 98
605003740 FCBS-A 3025 30 25 1982×1670×500 1842×1540 6 3 1.7 130
605003750 FCBS-A 3030 30 30 1982×1975×500 1842×1842 9 - 2 138
Other dimensions and arrangements available on request
74
Housings, frames & special applications
FCBL-CC
Advantages
• Easy to Install • Easy servicing
Pre-Filtration, Class G3 to F5
• No tools needed to change • Stable and secure design
filters • Modular construction
• Gasket to seal between door
and filter housing
Class F5 to F9
W D
H E PA / U L PA F i l t e r s , C l a s s
Unit
Exterior dimensions (WxHxD) Interior dimension (WxH) Number of Unit weight
Reference Type Model volume
mm mm cylinders kg
H10 to U17
m³
607002020 FCBL-CC 0510 05 10 399×744×750 309×610 8 0.23 25.5
607002040 FCBL-CC 1005 10 05 704×439×750 614×309 8 0.24 25.5
607002050 FCBL-CC 1010 10 10 704×744×750 614×614 16 0.4 33
607002060 FCBL-CC 1015 10 15 704×1055×750 614×925 24 0.57 49.5
607002070 FCBL-CC 1020 10 20 704×1360×750 614×1230 32 0.73 58.5
75
Housings, frames & special applications
Filter Housing
FCBL-CS
Advantages
• Easy to Install • Gasket to seal between door
• Modular construction and filter housing
• No tools needed to change • Easy servicing
filters • Stable and secure design
W D
Exterior dimensions (WxHxD) Interior dimensions (WxH) Number of Carbon Unit volume Unit weight
Reference Type Model mm mm panels m3 kg
611002040 FCBL-CS 1005 10 05 704x439x750 614x309 3 0.24 25.0
611002050 FCBL-CS 1010 10 10 704x744x750 614x614 6 0.40 32.5
611002060 FCBL-CS 1015 10 15 704x1055x750 614x925 9 0.57 51.5
611002070 FCBL-CS 1020 10 20 704x1360x750 614x1230 12 0.73 57.5
611002080 FCBL-CS 1025 10 25 704x1670x750 614x1540 15 0.90 73.5
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
611002090 FCBL-CS 1030 10 30 704x1975x750 614x1845 18 1.06 85.0
611002130 FCBL-CS 2010 20 10 1318x744x750 1228x614 12 0.75 51.5
611002140 FCBL-CS 2015 20 15 1318x1055x750 1228x925 18 1.06 84.0
611002150 FCBL-CS 2020 20 20 1318x1360x750 1228x1228 24 1.37 89.0
611002160 FCBL-CS 2025 20 25 1318x1670x750 1228x1540 30 1.68 117.5
611002170 FCBL-CS 2030 20 30 1318x1975x750 1228x1845 36 1.99 126.0
611002210 FCBL-CS 3010 30 10 1982x744x750 1842x614 18 1.13 73.5
611002220 FCBL-CS 3015 30 15 1982x1055x750 1842x925 21 1.60 111.0
611002230 FCBL-CS 3020 30 20 1982x1360x750 1842x1230 36 2.06 121.5
611002240 FCBL-CS 3025 30 25 1982x1670x750 1842x1540 45 2.53 162.0
611002250 FCBL-CS 3030 30 30 1982x1975x750 1842x1845 54 2.99 172.0
Other dimensions and arrangements available on request
76
Housings, frames & special applications
FCBL-HF
Advantages
• Easy to Install • Gasket to seal between door
Pre-Filtration, Class G3 to F5
• Modular construction and filter housing
• No tools needed to change • Easy servicing
filters • Stable and secure design
H E PA / U L PA F i l t e r s , C l a s s
Interior Unit
Exterior dimensions dimensions (WxH) Number of filter Number of filter Unit
H10 to U17
Reference Type Model (WxHxD) mm mm 592x592 mm 287x592 mm weight kg volume m3
77
Housings, frames & special applications
Te r m i n a l F i l t e r H o u s i n g s
Pharmaseal
Advantages
• Combines all the essential • Fully welded seams
functions required for • Controls and connections
pharmaceutical and accessible from room side
biotechnology facilities
• Capability to isolate the room
• Quick filter change during filter change
Supply Unit
With simplified control set: static pressure port, damper control, no aerosol dispersion port
Dimensions (WxHxD)
Reference Type Model Unit weight kg Unit volume m 3
mm
5502.03.12 Pharmaseal 6P6 PH-25D25D-12D-D-F-12-R-TS-A-C-2-D-2-A-2 641x641x311/305 13 0,17
5502.05.12 Pharmaseal 12P6 PH-25D49D-12D-D-F-12-R-TS-A-C-2-D-2-A-2 641x1251x311/305 25 0,34
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
Exhaust Unit
With complete control set: static pressure port, damper control, overall efficiency port
Dimensions (WxHxD)
Reference Type Model Unit weight kg Unit volume m 3
mm
5502.03.50 Pharmaseal 6P6 PH-25D25D-12D-D-F-12-R-TS-A-C-0-C-2-A-2 641x641x311/305 13 0,17
5502.05.50 Pharmaseal 12P6 PH-25D49D-12D-D-F-12-R-TS-A-C-0-C-2-A-2 641x1251x311/305 25 0,34
78
Housings, frames & special applications
Camsafe
Advantages
• Contact free filter change • Sealed, welded, solid design
Pre-Filtration, Class G3 to F5
• Automatic tension regulating • Tightness class B as per EN
filter clamping device 1866 at 5000 Pa
• Fast secure filter installation, • Ready flanged
lever operated • CamSafe connecting pieces can
• Optional filter seal seating test be supplied in various designs
as per DIN 1946, Part 4
W D Application: CamSafe chambers are used when filtering radioactive, toxic or bacterial particles
and gasses and provide maximum safety for the operator. Areas of use include laboratories,
isolation wards and the pharmaceutical industry. The casings can be joined together so that
Class F5 to F9
decontaminated, clamping device made from high grade steel 1.4301.
Steel casing: Manufactured in high grade steel 1.4301.
Standard design: Material thickness 2mm, flange drilled ready for operation, service cover
with male thread hand knobs, changing bag, support shelf for contact free filter changing,
automative tension regulating filter clamping device.
Options: Filter seal seating test device in accordance with DIN 1946 Part 4, pressure
compensation device and pressure check points.
Filter cartridges:
Prefilter P1: 610x610x47mm .
H E PA / U L PA F i l t e r s , C l a s s
Prefilter P2: 610x610x292mm.
Main filter: 610x610x292mm.
H10 to U17
All main filters come equipped with straps to aid the handling, enabling them to be changed
easily.
The filters can be supplied with a variety of gaskets to suit the application.
The casing is suitable for different classes of filter, suitable for dealing with glasses or particle
contamination.
Accessories: Safe change bags, manometers and material for the flanged joints supplied on
request.
79
Housings, frames & special applications
F i l t e r s f o r H i g h Te m p e r a t u r e
Termikfil 2000
Advantages
• Meets FDA requirements - • Exclusive precuring process
continuous 350°C, 99,99% at at 300°C carried out in the
0,3 μm plant
• Efficiency tested after • Ceramic frame
precuring
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
3415.02.00 TERMIKFIL 6P6 610x610x84 99.9 12.1 1200/250 5 0.04
3415.05.00 TERMIKFIL 4P6 457x610x84 99.9 8.9 900/250 4 0.03
3415.03.00 TERMIKFIL 7P6 762x610x84 99.9 15.3 1500/250 6 0.05
3415.04.00 TERMIKFIL 9P6 915x610x84 99.9 18.5 1800/250 8 0.06
80
Housings, frames & special applications
Absolute ® 1FRK
Advantages
• 99.97% DOP • High temperature resistant (up
Pre-Filtration, Class G3 to F5
to 350°C)
H E PA / U L PA F i l t e r s , C l a s s
213014F2 Absolute 1 FRK 1FRK-150-10 457x610x150 99.97 8.0 900/250 10 0.07
213017F2 Absolute 1 FRK 1FRK-600-10 610x610x150 99.97 11.0 1245/250 12 0.07
H10 to U17
213019F2 Absolute 1 FRK 1FRK-980-01 914x610x150 99.97 16.8 1925/250 16 0.11
213003F2 Absolute 1 FRK 1FRK-450-01 305x610x150 99.97 10.4 950/250 9 0.06
213021F2 Absolute 1 FRK 1FRK-725-01 610x457x292 99.97 16.4 1500/250 13 0.08
213010F1 Absolute 1 FRK 1FRK-1250-01 762x610x292 99.97 28.4 2625/250 21 0.17
213008F2 Absolute 1 FRK 1FRK-1000-01 610x610x292 99.97 22.5 2050/250 17 0.12
Model 01 = seal on air inlet side - Model 02 = seal on air outlet side - Other dimensions available on request
81
Housings, frames & special applications
Advantages
• Long lasting solution • Effective for a variety of
• Collapsible for transportation contaminants
EN 779:2002
IN
D
IE
DI
VI F
DU TI
ALLY CER
Reference Type Model Dimensions (WxL) m Air flow/ Pressure drop m 3 /hr/Pa Unit weight kg
AND 1 Standard AND 1 - 3 x 30 0.9 x 9.15 2700 / 30 9.80
AF Basic Standard AF Basic 3 x 30 0.9 x 9.15 2700 / 30 9.80
HEF 1330 Two Stage HEF 1330 - 3 x 30 0.9 x 9.15 2700 / 40 11.20
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
82
Housings, frames & special applications
Airopac ® HT-HF
Advantages
• High efficiency • Silicon free construction
Pre-Filtration, Class G3 to F5
• High temperature • Compact design
Class F5 to F9
IN
W
IE
DI
H E PA / U L PA F i l t e r s , C l a s s
Other dimensions available on request.
Also available in version without flange, for more information please contact us.
H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
83
Housings, frames & special applications
Advantages
• Compact design • Guaranteed silicone free
• Meets the requirements of the • Very high efficiency H10
surface treatment industry
EN 779:2002
IN
D
IE
DI
W
VI F
DU TI
D
ALLY CER
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
84
Housings, frames & special applications
CDM Media
Advantages
• Thermal bonded polyester fibre • Enhances laminar air flow
Pre-Filtration, Class G3 to F5
• Treated with special adhesive to patterns
prevent dust loss due to • Non toxic
vibration
Application: For fine filtration in air conditioning devices and installations, particularly final
filtration in Automotive spraybooths and drying cabinets.
Flammability: (DIN 53438) F1 self extinguishing.
Colour: White.
Media: Synthetic.
EN 779:2002 efficiency: F5.
D
IE
DI
VI
Class F5 to F9
F
TI
Humidity: 80 - 100% RH.
DU
ALLY CER
H E PA / U L PA F i l t e r s , C l a s s
TA600GI220 Roll TA-600 GI 2.0 x 20 F5 40 0.25 / 45 291 0.82 yes
TA600GI1620 Roll TA-600 GI 1.6 x 20 F5 32 0.25 / 45 291 0.4 yes
H10 to U17
TA600GI120 Roll TA-600 GI 1.0 x 20 F5 20 0.25 / 45 291 0.304 yes
SPEU480220 Roll SPEU-480 2.0 x 20 F5 40 0.25 / 23 399 0.615 yes
Other sizes and cut pads available on request.
85
Housings, frames & special applications
F i l t e r s f o r G a s Tu r b i n e s
Cam GT ®
Advantages
• Suitable for high humidity • Very robust construction
conditions • Corrosion resistant
• Burst pressure 7500 Pa • Can be used to upgrade existing
• Patented draining pleating installations
Application: Air intake for gas turbines, compressors and large engines.
Type: High efficiency, incinerable compact filter.
Frame: Polypropylene and ABS.
Gasket: Expanded polyurethane placed on the downstream side (code 01).
Media: Glass fibre paper.
Separator: Hot-melt beads.
Sealant: Polyurethane.
Grid: Glass fibre reinforcement grid placed downstream.
W D
EN 779:2002 efficiency: F7. F9.
EN 1822 efficiency: H10.
Recommended final pressure drop: 600 Pa.
Temperature: 80°C maximum in continuous service.
N.B: Burst pressure: > 7500 Pa.
EFFICIENCY
GUARANTEE
Dimensions Filter classification Media Air flow/pressure drop Unit weight Unit Volume Energy
Reference Unit Type Model (WxHxD) mm EN 779:2002 area m² m³/h/Pa kg m³ Rating
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
1530.58.50 CAM GT-H10 CAM GT H10-241212/01 592x287x290 H10 9 2125/250 5 0.05
Available with gasket on upstream side (10). Available in reverse flow version.
86
Housings, frames & special applications
Campulse EF
Advantages
• Specially designed for very • Air intake for gas turbines,
Pre-Filtration, Class G3 to F5
dusty environments compressors and large engines
• Desert and arctic environments
Class F5 to F9
E
C
EN 779:2002 Recommended air flow per set of cartridges CY-2612/CO-2612: 2500 m3/h.
IN
VI I F
DU RT
ALLY CE
H E PA / U L PA F i l t e r s , C l a s s
CO-2612 660 445/324 25.41 1261/211 F9 0.142 9
H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
87
Housings, frames & special applications
F i l t e r s f o r G a s Tu r b i n e s
Hi-Flo ® T
Advantages
• Reinforced filter media • Rigid design concept
• Suitable for turbulent air flow • High burst strength
conditions
EFFICIENCY
GUARANTEE
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
538012A3 Hi-Flo T 3 XMT-95 592x592x655 F8 7.8 3400/115 5.0 0.05
538013A3 Hi-Flo T 3 ZMT-95 287x592x655 F8 3.9 1700/115 3.0 0.03
Other dimensions available on request.
88
Housings, frames & special applications
Gold Series
Advantages
• High collector efficiency using • Modular design for optimum
Pre-Filtration, Class G3 to F5
HemiPleat cartridges flexibility
• Up to 25% smaller • Easy to install and maintain
• Customised for Original • Simple cartridge replacement
Equipment Manufacturers using quick release cam bars
(OEM)
Application: Gold Series cartridge dust and fume collectors may be used for a wide range of
pollution control and product recovery applications.
Type: Pulse cleaning, cartridge based dust collector with high performance filter elements.
Cleaning is accomplished by pulse waves that emanate from the centre of the filter providing
Class F5 to F9
carbon steel for the doors, hopper and panels.
Finish: As standard in a green, durable, corrosion resistant powder coated finish. Alternative
construction and colours are also available.
Options: A wide variety of options are available including: Explosion Venting, Special Inlet
Designs, BIBO (bag in-bag out) for Pharmaceutical Applications, Custom Colours, Stainless
Steel Construction, Alternative Hopper Designs etc. please contact us with your specific
requirements.
Cartridges: Vertically mounted to shed dust readily for efficient cleaning and longer service life.
High filtration efficiency meeting the 5 mg/m3 or less emissions required to re-circulate the air
H E PA / U L PA F i l t e r s , C l a s s
back into the work place on non hazardous dusts.
H10 to U17
Easy Access Door
• No Knobs To Lose or Drop
Powerful Cleaning
• No Threads To Bind
System to Provide
• Mechanically Attached Seal
Long Filter Life
• Heavy 10 gauge Construction
• Lock-Out/Tag-Out Capability
Easy Changeout
Gold Cone Cartridge with patented
Cambar action that positively seals High Entry Inlet
the cartridges without using Cross flow is created through the filters.
threads or knobs. Eliminates upward “can” velocities associated
with traditional hopper inlets.
89
Housings, frames & special applications
Dust Collector
HemiPleat Cartridges
Advantages
• High efficiency, 99.999% at • Open pleat spacing to enhance
0.5μ and above cleaning cycle
• Low pressure drop • Easy to install using quick
• Reduced energy cost release cam bars
• Long filter life • Double seal gasket for added
security
Application: HemiPleat cartridges may be used for a wide range of pollution control and
product recovery applications.
Type: Pleated media cartridge with improved pleat spacing and media alignment.
Construction: Vertically mounted to shed dust readily for efficient cleaning and longer service
life. Features a cone in the centre of the cartridge to distribute the air pulse and enhance the
cleaning cycle.
Media: Several different types of filter media, pre-coat materials and over bags are available to
suit specific operating conditions. Please contact us to make this selection.
Efficiency: 99.999% at 0.5μ and above.
Options: Filter cartridge options are available to suit specific operating conditions. These
include Carbon Impregnated, Fire Retardant, Ultra High Efficiency, PTFE, and High Temperature.
Please contact us to make this selection.
Dimensions
Reference Type Model Media Type (dia. x L) mm Media area m 2 Unit weight kg
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
90
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
Notes
Housings, frames & special applications
www.camfilfarr.co.uk
Knowsley Road, Haslingden, Lancashire, BB4 4EG
Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
91
A i r F i l t e r Te c h n o l o g y Filter Frames and Housings Carbon and Chemical Filters H E PA / U L PA F i l t e r s , C l a s s Bag and Compact Filters, Pre-Filtration, Class G3 to F5 Camfil Farr Solutions
H10 to U17 Class F5 to F9
A i r F i l t e r Te c h n o l o g y
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
F8 - 90 ≤Em < 95 EU 8 1.000,000 M6 - - - - -
F9 - 95 ≤Em EU 9 3.530,000 M 6.5 100,000 ISO 8 4.000,000 D -
92
A i r F i l t e r Te c h n o l o g y
Pre-Filtration, Class G3 to F5
M2 - 3,500 757 309 100 - Hi-Flo 3P 85 6.5 m2 120 Pa 3.500 hours
M 2.5 10 12,400 2,650 1,060 353 -
Hi-Flo 3M 85 9.4 m2 100 Pa 6.500 hours
M3 - 35,000 7,570 3,090 1,000 -
Gain 3 m2 20 Pa 3.000 hours
M 3.5 100 - 26,500 10,600 3,530 -
+ 86% in operating life
M4 - - 75,700 30,900 10,000 - Conclusion + 46% in surface (x 1.5)** - 17% in energy
(x 1.9)**
M 4.5 1000 - - - 35,300 247
* Determined using the Camfil Farr calculation charts in the Hi-Flo brochure, for an average town
M5 - - - - 100,000 618 environment
M 5.5 10,000 - - - 353,000 2,470 ** factor of increase
M6 - - - - 1.000,000 6,180
Energy costs
M 6.5 100,000 - - - 3.530,000 24,700
Energy consumed by an air filter due to its pressure drop:
M7 - - - - 10,000,000 61,800
particles / m3 = 10M(0.5/d)2 . 2
particles / ft3 = Nc(0.5/d)2 . 2 The Efficiency %
Class F5 to F9
Air quality of premises with non specific pollution
The Purification coefficient (no units)
Regulatory aspect Recommendations
Labour code / Circular of
application of decrees 84/1093- UNICLIMA Air-conditioning & Health guide (1993) q = flow rate (m3/s)
1094 dated 7/12/1984
dP = pressure drop (Pa)
Labour code Art. R235.2.6 Air-conditioning system inlet: 85% opacimetric (F7
Minimum arrestance according to EN 779:2002) Air-conditioning system
h = operating period (hours)
Fresh air ef = fan efficiency (generally 0.6 to 0.7)
efficiency 90% (G4 according outlet: 90% opacimetric (F8 according to EN
to EN 779:2002) 779:2002)
Labour code Art. R232.5.4 Acronyms and abrivations
Recycled Minimum opacimetric
85% opacimetric (F7 according to EN 779:2002)
H E PA / U L PA F i l t e r s , C l a s s
air efficiency 50% (F5 according AFNOR French standardisation body
to EN 779:2002) American Society of Heating, Refrigerating and Air-conditioning Engineers
ASHRAE
(USA)
FILTER ENGINEERING - Calculations ASPEC Association for prevention and study of contamination (France)
H10 to U17
An air filter’s efficiency is expressed in 3 forms: BSI British Standards Institute
CEN European standardisation body
formulas CETIAT Technical centre for air handing and thermal industries (France)
CNC Condensation Nucleus Counter
q x dP x h
E= = kWh VOC Volatile Organic Compounds
ef x 1000 CSTB Scientific and technical centre for construction (France)
DEHS Di-Etil-Hexil-Sebaçate (= DES = DOS)
Clearly the purification coefficient is the most representative expression for high DIN Deutsches Institut für Normung
levels of filtration. E.g.: DOP Di-Octil-Phtalate
Comperative efficiencies
on 1 μm on 0.5 μm
E P PC E P PC
90% ARRESTANCE 10% 90% 1.1 5% 95% 1.05
50% EFFICIENCY 30% 70% 1.4 10% 90% 1.1
65% EFFICIENCY 45% 55% 1.8 25% 75% 1.3
85% EFFICIENCY 85% 15% 6.6 70% 30% 3.3
95% EFFICIENCY 95% 5% 20 90% 10% 10
95% 0.3 μm ≥ 98% < 2% ≥100 ≥98% <2% ≥ 50
E = Efficiency, P = Penetration, PC = Purification Coefficient
A i r F i l t e r Te c h n o l o g y
93
A i r F i l t e r Te c h n o l o g y
Energy
1 kcal/kg = 4.19.103 J/kg 1 J/kg = 0.239.10-3 kcal/kg Diagram of Whitby: This diagram shows that more than 99.90% of airborne
particles are less than or equal to 1 μm in size.
Heat transmission Therefore, the essential part of air filtration’s activity takes place in the invisible
1 kcal/h.m².°C = 1.16 W/(m².°C) 1 W/(m².°C) = 0.86 kcal/h.m².°C domain (human ocular partition power: 30 μm).
1 Btu/(h.ft².°F) = 5.64 W/(m².°C) 1 W/(m².°C) = 0.177 Btu/(h.ft².°F)
Diagram of particle sizes
FILTER ENGINEERING - Theory
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
MPPS
Minimum efficiency of air filters
94
A i r F i l t e r Te c h n o l o g y
Pre-Filtration, Class G3 to F5
plans, specifications, designs and computer software or otherwise), database rights, topography rights, 5.2 The Company shall agree with the Buyer the date and the place at which the Goods shall be ready for
any rights in any invention, discovery or process, and applications for and rights to apply for any of the testing and commissioning as provided for in the Contract.
foregoing, in each case in the United Kingdom and all other countries in the world; “Operational 5.3 Any dates specified by the Company for testing and commissioning as provided for in the Contract
Parameters” operational conditions under which the Goods will operate safely and effectively as referred are approximate only and may not be made of the essence by notice.
to in the quotation; “Practical Completion” the completion of the provision of the agreed Services by the 5.4 Company’s Obligations
Company; “Services” any design work, assembly, installation, testing, commissioning and maintenance 5.4.1 Subject to the provisions of the Contract, the Company shall with due skill and care design,
services which the parties have agreed the Company is to supply to the Buyer (including any of them or manufacture and deliver to site, erect, test and commission the Goods, carry out the Services and
any part of them); “Site” the site at which the Company is to perform the Services; “Specification” the complete any tests provided for in the Contract.
written specification of technical requirements by the Buyer in relation to the provision of the Goods and/ 5.5 Buyer’s Obligations
or Services by the Company. 5.5.1 The Buyer shall provide (or shall procure the provision of) at its own expense and in a timely
1.2 The headings in these terms and conditions are for convenience only and shall not affect their manner the Company and its employees, agents and sub-contractors with:
interpretation. 5.5.1.1 all necessary access to the Site in reasonable time for the proper performance of the Contract
and to include access to such roads or other means of access as may be necessary;
2. Formation and incorporation 5.5.1.2 all relevant consents, wayleaves, approvals, import licences and permits as are required for the
2.1 Subject to any variation under condition 2.4, each Contract will be on these terms and conditions to provision of the Services by the Company;
the exclusion of all other terms and conditions (including any terms or conditions which the Buyer 5.5.1.3 all building structures, foundations, approaches or work equipment or materials within the time
purports to apply under any purchase order, confirmation of order or similar document). specified in the Contract and of the quantity specified and in a condition suitable for the efficient
2.2 The order for Goods and Services by the Buyer from the Company shall be deemed to be an offer by transportation, reception, installation and maintenance of the Goods and/or Services;
the Buyer to purchase such Goods and Services subject to these terms and conditions. 5.5.1.4 any suitable lifting equipment belonging to the Buyer that may be available on Site to operate for
the purposes of the Services;
Class F5 to F9
shall have no effect unless expressly agreed in writing and signed by either the Commercial Manager or a by the Company that may be specified in the Contract;
Director of the Company. The Buyer must ensure that the terms of its purchase order and any applicable 5.5.1.7 where the Contract provides for any tests or commissioning on Site, unless otherwise stated in
Specification are complete and accurate. the Contract, such fuel, electricity and other services or materials that may reasonably be requested by
2.5 Acceptance of delivery of the Goods or commencement of the performance of the Services shall be the Company to enable such tests or commissioning to be carried out effectively;
deemed to be conclusive evidence of the Buyer’s acceptance of these terms and conditions. 5.5.1.8 access to a canteen or restroom (where available);
2.6 Any quotation is given on the basis that no Contract will come into existence until the Company 5.5.1.9 appropriate waste disposal facilities (including, without limitation, a designated waste point on
despatches a written acknowledgement of order to the Buyer. Any quotation is valid for a period of 30 Site); and
days only from its date provided the Company has not previously withdrawn it. 5.5.1.10 all assistance as may be reasonably required by the Company as necessary for the proper
2.7 No order which the Company has accepted may be cancelled by the Buyer except with the written performance of the Contract.
agreement of the Company in response to a written request of the Buyer and on terms that the Buyer
shall indemnify the Company in full against all losses (including loss of profit), costs, damages, charges
and expenses suffered or incurred by the Company as a result of such cancellation. 5.6 Where the Services are to be performed or the Goods are to be supplied outside the UK, the Buyer
will assist the Company to ascertain the nature and extent of and to comply with laws, regulations, orders
or by-laws of any local or national authority having the force of law in the country where the Services are
3. Description
to be performed or the Goods supplied, or which may affect the Company in the performance of its
H E PA / U L PA F i l t e r s , C l a s s
3.1 The description of the Goods and Services shall be as set out in the Company’s quotation. Any obligations under the Contract.
Specifications, drawings etc. intended to form part of the Contract will be referred to in the quotation. 5.7 Unless otherwise agreed in writing by the Company, any dates specified by the Company for
3.2 Except where express agreement to the contrary in writing has been made with the Buyer, the Practical Completion are approximate only and may not be made of the essence by notice. If no dates
Company may make any changes to the specification, design, materials or finishes of the Goods: are so specified, Practical Completion will be within a reasonable time of the Company being provided
3.2.1 which are required to conform with any applicable safety or other statutory requirements; or
H10 to U17
with suitable access to the Site.
3.2.2 which it deems desirable and which do not materially affect their quality or performance. 5.8 Subject to the other provisions of these terms and conditions the Company will not be liable for any
3.3 No variation in the specification or design of any Goods which, in the Company’s reasonable opinion, loss (including loss of profit), costs, damages, charges or expenses caused directly or indirectly by any
does not adversely affect the suitability of the Goods for the particular purpose for which they are delay in or failure to achieve the Practical Completion by any date or within any time period set out in the
supplied by the Company will constitute a breach of contract or impose any liability upon the Company. Contract (even if caused by the Company’s negligence).
5.9 Where the Company incurs extra cost during the provision of the Services resulting from suspension
4. Delivery of the goods of work, the Buyer’s instructions or lack of instructions, the Buyer’s act or omission, the Buyer’s failure or
4.1 Delivery of the Goods shall be made on the basis and at such place as agreed between the parties delay to comply with the obligations of condition 5.5 and 5.6, interruptions, delays, overtime, unusual
and as set out by the Company in the written acknowledgement of order in accordance with condition hours, mistakes, or work for which the Company is not responsible, such extra cost as well as the cost
2.6. incurred by keeping any of the workforce on Site after completion of the Services on Site, shall be added
4.2 The Buyer will take delivery of the Goods within 10 days of the Company giving it notice that the to the Contract price and be for the account of the Buyer and in accordance with the provisions of the
Goods are ready for delivery. The Buyer must accept delivery of the Goods and pay for them in full. Contract.
4.3 Notwithstanding condition 4.1, any dates specified by the Company for delivery of the Goods are 5.10 Where Services have been provided by the Company the Goods shall be deemed to be accepted by
approximate only and may not be made of the essence by notice. the Buyer at the earlier of:
4.4 If the Buyer fails to take delivery of the Goods when they are ready for delivery pursuant to condition 5.10.1 the Company certifying in writing that erection is complete, or where the Company is required to
4.1 or to provide any instructions, documents, licences or authorisations required to enable the Goods to test the Goods on Site, the Company certifying that the Goods have passed such tests; or
be delivered on time (except because of the Company’s fault) risk in the Goods will pass to the Buyer 5.10.2 the Buyer taking over the Goods.
(including, without limitation, for loss or damage caused by the Company’s negligence); the Goods will be 6. Force majeure
deemed to have been delivered and (without prejudice to its other rights) the Company may: 6.1 The Company shall not be liable to the Buyer in any manner or be deemed to be in breach of a
4.4.1 store or arrange for the storage of the Goods until actual delivery or sale and charge the Buyer for Contract (subject to condition 10) because of any delay in performing or any failure to perform any of the
all related costs and expenses (including, without limitation, storage and insurance); and/or Company’s obligations under this Contract if the delay or failure was due to any cause beyond the
4.4.2 following written notice to the Buyer, sell any of the Goods at the best price reasonably obtainable Company’s reasonable control.
in the circumstances and charge the Buyer for any shortfall below the price under the Contract. 6.2 Without prejudice to the generality of condition 6.1 the following shall be included as causes beyond
4.5 If carriage is required in accordance with condition the Company’s reasonable control:
4.5.1 the Goods shall be transported by such means as the Company thinks fit unless the Buyer has 6.2.1 governmental actions, war or threat of war, national emergency, riot, civil disturbance, sabotage,
specified in its order the details of the contract with a carrier which it reasonably requires having regard terrorism or threat of terrorism or requisition;
to the nature of the Goods and the other circumstances of the case. 6.2.2 Act of God, fire, explosion, flood, epidemic or accident;
4.6 Off-loading by the Buyer 6.2.3 import or export regulations or embargoes;
4.6.1 Where it is agreed that the Buyer shall off-load the Goods the Buyer will provide at its expense at 6.2.4 labour disputes not including disputes involving the Company’s work-force;
the Delivery Point adequate and appropriate equipment and manual labour for off-loading the Goods. 6.2.5 inability to obtain or delay in obtaining supplies of adequate or suitable material, fuel, parts,
4.6.2 Where condition machinery or labour; or
4.6.1 applies, the Buyer will indemnify the Company against any liability and expense (whether arising 6.2.6 any failure or negligence or breach of contract on the part of the Buyer or its sub-contractors,
Filter Frames and Housings
under statute or common law) caused by the Buyer’s failure to provide appropriate equipment and contractors, agents or employees.
manual labour for off-loading (whether or not the off-loading is supervised by or on behalf of the Buyer)
for: 7. Risk/Ownership
4.6.2.1 any personal injury to or death of any of the Company’s employees, agents or sub-contractors or
any third party; and 7.1 Risk or damage to or loss of Goods shall pass to the Buyer upon delivery of the Goods, (unless
4.6.2.2 any damage to or loss of any property of the Company, its employees, agents or sub-contractors otherwise agreed in writing by the parties).
or any third party. 7.2 Ownership of the Goods shall not pass to the Buyer until the Company has received in full (in cash or
cleared funds) all sums due to it in respect of:
4.7 Instalments 7.2.1 the Goods and Services; and
4.7.1 The Company may make delivery of the Goods by instalments. 7.2.2 all other sums which are or which become due to the Company from the Buyer on any account.
4.7.2 Each separate instalment shall be invoiced and paid for in accordance with the Contract. 7.3 Until ownership of the Goods has passed to the Buyer, the Buyer must:
4.7.3 Failure by the Company to deliver any one or more (but not all) instalments in accordance with a 7.3.1 hold the Goods on a fiduciary basis as the Company’s bailee;
Contract or any claim by the Buyer in respect of any one or more (but not all) instalments shall not entitle 7.3.2 store the Goods (at no cost to the Company) separately from all other goods of the Buyer or any
the Buyer to treat that Contract as repudiated. third party in such a way that they remain readily identifiable as the Company’s property;
4.7.4 Failure by the Buyer to pay for any one or more instalments in accordance with a Contract shall 7.3.3 not destroy, deface or obscure any identifying mark or packaging on or relating to the Goods;
entitle the Company (without prejudice to its other rights and remedies): 7.3.4 maintain the Goods in satisfactory condition insured on the Company’s behalf for their full price
4.7.4.1 to suspend without further notice deliveries of Goods or goods under any other contract between against all risks to the reasonable satisfaction of the Company. On request the Buyer shall produce the
the Company and the Buyer pending payment by the Buyer; and/or policy of insurance to the Company; and
4.7.4.2 to treat that Contract as repudiated by the Buyer. 7.3.5 hold the proceeds of the insurance referred to in condition 7.3.4 on trust for the Company and not
4.8 Non-Delivery of the Goods mix them with any other money, nor pay the proceeds into an overdrawn bank account.
4.8.1 Irrespective of condition 4.5, the quantity of any consignment of Goods as recorded by the 7.4 The Buyer may resell the Goods before ownership has passed to it solely on the following conditions:
A i r F i l t e r Te c h n o l o g y
Company upon despatch from the Company’s place of business shall be conclusive evidence of the 7.4.1 any sale shall be effected in the ordinary course of the Buyer’s business at full market value and the
quantity received by the Buyer on delivery unless the Buyer can provide conclusive evidence proving the Buyer shall account to the Company accordingly; and
95
A i r F i l t e r Te c h n o l o g y
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
Buyer). This obligation will not apply where: 14.2 Each right or remedy of the Company under the Contract is without prejudice to any other right or
10.1.2.1 the Buyer has failed to notify the Company of any defect or suspected defect within 14 days of remedy of the Company whether under the Contract or not.
the delivery where the defect should be apparent on reasonable inspection, or within 14 days of the same 14.3 Any provision of the Contract which is held by any competent authority to be invalid, void, voidable,
coming to the knowledge of the Buyer (where the defect is not one which should be apparent on unenforceable or unreasonable (in whole or in part) shall to the extent of such invalidity, voidness,
reasonable inspection) and in any event no later than 12 (twelve) months from the date of delivery; or voidability, unenforceability or unreasonableness be deemed severable and the other provisions of the
10.1.2.2 the Buyer has failed to give the Company a reasonable opportunity of examining such Goods Contract and the remainder of such provision shall not be affected.
after receiving the notice of any defect or suspected defect; or 14.4 Failure by the Company to enforce or partially enforce any provision of the Contract will not be
10.1.2.3 the defect arises because the Buyer (or the Buyer’s customer) failed to follow the Company’s construed as a waiver of any of its rights under the Contract.
oral or written instructions as to the storage, installation, testing and commissioning (if applicable), use, 14.5 The Company may assign, license or sub-contract all or any part of its rights or obligations under
Operational Parameters or maintenance of the Goods or (if there are none) good trade practice; or the Contract without the Buyer’s consent.
10.1.2.4 the Buyer (or the Buyer’s customer) alters or repairs such Goods or without the written consent 14.6 The Contract is personal to the Buyer who may not assign, license or sub-contract all or any of its
of the Company; or rights or obligations under the Contract without the Company’s prior written consent.
10.1.2.5 the defect in such Goods arises from any defect in any drawing, design, Specification or 14.7 The Company and the Buyer do not intend that any of the terms of the Contract will be enforceable
instruction supplied or approved by the Buyer. Any Goods replaced will belong to the Company and any by virtue of the Contracts (Rights of Third Parties) Act 1999 by any person not a party to it.
repaired Goods or replacement Goods will be guaranteed on these terms and conditions for the 14.8 The formation, construction, performance, validity and all aspects of the Contract are governed by
unexpired portion of the 12 (twelve) month period from the original date of delivery of the replaced English law and the parties submit to the non-exclusive jurisdiction of the English Courts.
Goods.
10.1.3 Any Goods repaired or replaced by the Company pursuant to this condition 10 will be supplied to
these terms and conditions.
10.1.4 If the Company complies with condition 10.1.2 it shall have no further liability for a breach of
warranty in condition
10.1.5 in respect of the quality of such Goods.
10.2 Indemnity and Limitation of liability
10.2.1 The Buyer shall indemnify the Company against all liability, actions, proceedings, costs, claims,
damages or demands in any way connected with this Contract brought or threatened to be brought
against the Company by any third party except to the extent the Company is liable to the Buyer in
accordance with these terms and conditions.
10.2.2 Subject to condition 10.1.1 and to the maximum extent permissible in law, all conditions and
warranties which are implied by statute or otherwise by general law into any Contract or relating to the
Goods or the Services are hereby excluded.
10.2.3 The Company does not, unless otherwise expressly provided in the Contract, warrant that the
Services or the Goods as described or provided or the incorporation thereof within some larger project
will satisfy the Buyer’s requirements.
10.2.4 The Company will accept unlimited liability for:
10.2.4.1 death or personal injury caused by the negligence of the Company; and
10.2.4.2 any breach of its obligations implied by Section 12 of the Sale of Goods Act 1979 or Section 2
of the Supply of Goods and Services Act 1982; and
10.2.4.3 fraudulent misrepresentation.
THE BUYERS ATTENTION IS IN PARTICULAR DRAWN TO THE PROVISION OF CONDITION 10.2.5
10.2.5 Subject to conditions 10.2.2, 10.2.3 and 10.2.4:
10.2.5.1 except in the case of any liability on the part of the Company referred to in condition 10.2.4, the
96
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
Notes
A i r F i l t e r Te c h n o l o g y
www.camfilfarr.co.uk
Knowsley Road, Haslingden, Lancashire, BB4 4EG
Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
97
A i r F i l t e r Te c h n o l o g y Filter Frames and Housings Carbon and Chemical Filters H E PA / U L PA F i l t e r s , C l a s s Bag and Compact Filters, Pre-Filtration, Class G3 to F5 Camfil Farr Solutions
H10 to U17 Class F5 to F9
Cover 3_080616.pdf 2008-06-16 13:25:34
MANCHESTER LONDON
Head Office & Manufacturing Plant
Camfil Limited MIDLANDS
Knowsley Road
Haslingden SCOTLAND
Lancashire
BB4 4EG
Tel: +44 (0) 1706 238000
Fax: +44 (0) 1706 226736
AIR HYGIENE
Viv Turner
AUTOMOTIVE
C Mark Taylor
M
COMFORT SEGMENT
Y
CY
Peter Dyment
CMY
CONTAINMENT SYSTEMS
K
Mike Vinson
DUST CONTROL
Manchester
John Purvis/Matthew Brown
FOOD INDUSTRY
Birmingham
Tim Pagett
GAS TURBINE
Martin Stenton
London
HOSPITALS
Dave Rimmer
MOLECULAR FILTRATION
Chris Ecob
PHARMACEUTICAL
Neil Orrill
VEHICLE REFINISHING
www.camfilfarr.co.uk Gary Warrington
On world standards...
www.camfilfarr.co.uk
Camfil Limited
Knowsley Road
Haslingden
Lancashire
BB4 4EG
Tel: +44 (0) 1 706 238000
Fax: +44 (0) 1 706 226736
E-mail: sales@camfil.co.uk