Vous êtes sur la page 1sur 4

Installation

FLUENT™
Instructions
T186.500
PRESSURE BALANCING T186.501 H H

BATH AND SHOWER T186.502


Of f
C
Of f
C

TRIM KITS
T186.507
T186.508

Thank you for selecting American-Standard...the benchmark of fine 507/508 500/501/502


quality for over 100 years.

To ensure that your installation proceeds smoothly-- please read these Certified to comply with ANSI A112.18.1
instructions carefully before you begin. M965625 REV. 1.1 (11/14)

RECOMMENDED TOOLS

Phillips Screwdriver

Adjustable Wrench Slip Jaw Pliers


Plumbers' Putty or Caulking Teflon Tape Flat Blade Screwdriver

ROUGHING-IN DIMENSIONS (For reference only)


To assure proper positioning in relation to wall, note roughing-in dimensions.

2-7/32" D.
(57mm) INLETS
4-1/16"
(103mm) INLETS
SHR. 1/2" NOM.(13mm) 1/2" NOM. (13mm)
COPPER SWEAT COPPER
5" REF. SWEAT
(127mm)
SWEAT
INLETS
1-7/8" to 3-1/4" 2"
(48 to 83 mm)
4-1/16"
(103mm)
8-1/2" REF. 1/2" NPT TUB 1/2" (13mm) NOM.
(216mm) COPPER SWEAT
(13mm)

SWEAT
3-3/4" REF.
INLETS (STOPS)
(95mm)
5-7/8"
OPTIONAL TO FINISHED
(149mm)
FLOOR USUALLY
BETWEEN 65'' AND 80''
(1651 and 2032mm)' SHR. 1/2" NOM.(13mm) 4-1/16"
7-1/2" REF. COPPER SWEAT (103mm)
(191mm)
TUB 1/2" NOM. (13mm)
FINISHED COPPER SWEAT
WALL
INLETS
1/2" NOM.
"SEE ILLUSTRATION " (13mm)
74" FOR HEAD COPPER
CLEARANCE SWEAT
(1880mm)
OUTLETS
8" DIA. 1/2" NPT
(204mm) INLETS 1/2" NPT (13mm} (13mm)

5-7/8" INLETS
3-3/8" (149mm) 1/2" NPT
(86mm) (13mm)
18" OPTIONAL
(457mm)
3-3/8"
1-3/4" (86mm)
(44 mm)
OUTLETS 3-3/8"
1/2" NPT (86mm)
(13mm)

1/2" COPPER
6-19/32" REF.
(167mm) 4" (102mm)
THREADED INLETS THREADED INLETS (STOPS)
TOP OF TUB RIM

BOTTOM OF TUB
1 INSTALL VALVE TRIM

Figure 1. Remove plaster guard from valve. Push CAP (1)


over VALVE CARTRIDGE (2) until seated against stop. 1
PLSTER
GUARD
Figure 2. Push ESCUTCHEON (3) onto CAP (1). Align
mounting holes in ESCUTCHEON (3) with valve body.
Attach to valve body with LONG SCREWS (4).

Figure 3. Align PIN (5) on back of DIAL PLATE (6) with 2


hole in ESCUTCHEON (3). Push DIAL PLATE (6) onto
CAP (1) flush against ESCUTCHEON (3). Figure 1.

1 3 HOLE IN ESCUTCHEON (3)

4
6
H

Of f C

Figure 2. 1
Figure 3.
3

2 INSTALL TRIM
CAUTION: Protect finish on SHOWER HEAD
and TUB SPOUT when installing. 3 INSTALL HANDLE

Note: Apply sealant or Teflon Tape to shower arm. Hold ADAPTER (1) onto VALVE STEM (2) and install
Remove PIPE PLUG and CAP (1, 2) from shower pipe and tub ADAPTER SCREW (3) through ADAPTER (1) into
filler pipe. VALVE STEM (2).Tighten ADAPTER SCREW (3) to
secure ADAPTER (1).
Install SHOWER ESCUTCHEON (3) onto SHOWER
ARM (4). Apply sealant or Teflon tape to threads on Align and install HANDLE (4) onto ADAPTER (1).
both ends of SHOWER ARM (4) and thread longer Tighten SET SCREW (5) with HEX WRENCH (6)
leg of SHOWER ARM (4) into shower elbow. supplied.
Thread SHOWER HEAD (5 or 5a) onto SHOWER ARM (4).

Install SLIP-ON TUB SPOUT (6). Tighten SET SCREW (7) with
HEX WRENCH supplied.
Important: Do not overtighten Set Screw.

4 H
3

1
Of f C
4
APPLY SEALANT OR
5
TEFLON TAPE TO
THREADS

1
2
5a 5
2
6

1-3/4"
7 6

HEX WRENCH M965625 REV. 1.1 (11/14)


4 ADJUST HOT LIMIT STOP 2 3
4 5
97531
311
By restricting HANDLE rotation and limiting the amount of hot
0 1
15

water allowed to mix with the cold, the HOT LIMIT SAFETY
STOP (1) reduces risk of accidental scalding. To set the maximum 1
hot water temperature of your faucet, all you need to do
is adjust the setting on the HOT LIMIT SAFETY STOP (1).
Turn CARTRIDGE STEM (2) to the OFF position (coldest setting) before 3
making adjustment to HOT LIMIT STOP (1). Use a flat blade screwdriver to pry
free the HOT LIMIT SAFETY STOP (1). Pull off and rotate counterclockwise
to the desired number to limit hot water temperature. Use ARROW (3) on
CARTRIDGE (4) and NUMBERS (5) on HOT LIMIT STOP (1) for indication. 2
HOTTER
1
5
1
3

(Smaller Numbers)

1
5

1
9
7
5
0 1 3 5 7 9 11 13 15

3
TO GAIN ACCESS TO VALVE FOR SERVICING

1
5
Remove HANDLE (see step 3 and reverse).
15
1
3
1

1
4

9
7
1

5
3
1
Remove ESCUTCHEON and CARRIDGE CAP (see step 1 and reverse). COLDER
Shut off water supply by either closing off main water supply, or closing off (Larger Numbers)
the hot and cold CHECK STOPS on valve. 0 1 3 5 7 9 11 13 15

VALVE LEAKS WHEN SHUT OFF


Remove CARTRIDGE (1) by removing CARTRIDGE SCREWS (2). Remove three SCREWS (3) from FIXATION RING (4) and
pull out PRESSURE BALANCING UNIT (5).

Clean SEALS (9) on base of CARTRIDGE (1). Check base of PRESSURE BALANCING UNIT (5) and clean O-RINGS (6). Remove
CAPS (7) and check O-RINGS on inside of CAPS (7). Clean inside sealing surfaces of VALVE BODY (8).

Re-assemble PRESSURE BALANCING UNIT (5) and CARTRIDGE (1). Tighten all screws.

Turn on water supply and see above for installing TRIM and HANDLE.

UNABLE TO MAINTAIN CONSTANT TEMPERATURE


Remove CARTRIDGE (1) by removing CARTRIDGE SCREWS (2). Remove three SCREWS (3) from FIXATION RING (4) and
pull out PRESSURE BALANCING UNIT (5).

Remove CAPS (7) and clean valve thoroughly.

Examine balancing unit and check condition of O-ring on end of piston. Piston should move back and forth. Order Repair
Part M952100-0070A if balancing unit is defective.

Replace CAPS (7) and install PRESSURE BALANCE UNIT (5). Make sure inlets line up with two holes in bottom of casting.
Top flange should butt-up against top of casting.

BACK TO BACK INSTALLATION


Remove CARTRIDGE (1) by removing CARTRIDGE SCREWS (2). Remove three SCREWS (3) from FIXATION RING (4) and
pull out PRESSURE BALANCING UNIT (5). Rotate PRESSURE BALANCE UNIT (5) 180˚ so that the inlets face up and the
large outlet port faces down.

Push PRESSURE BALANCE UNIT (5) in casting make sure inlets line up with holes in bottom of casting. Top flange should
butt up against top of casting.

Reassemble FIXATION RING (4) and CARTRIDGE (1).

4 ROTATE 180˚
1 LARGE OUTLET

5
8 7
6 5 INLETS
3
9 2 BACK TO BACK INSTALLATION

6 CARE INSTRUCTIONS:

DO: CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE. M965625 REV. 1.1 (11/14)
FLUENT™
PRESSURE BALANCE
BATH/SHOWER
MODEL NUMBER

T186.500
060337-YYY0A
SHOWER ARM A919542-YYY0A
T186.501
FLANGE SHOWER ARM T186.502
T186.507
T186.508

1660604.XXX
SHOWER HEAD

M907050-YYY0A 1660717.XXX
ESCUTCHEON CAP SHOWER HEAD

M909349-YYY0A
DIAL PLATE

M907813-YYY0A M918039-0070A
ESCUTCHEON KIT HANDLE ADAPTER

M964928-YYY0A
LEVER HANDLE KIT
Of f C

078016-YYY0A
ESCUTCHEON SCREWS

A918477-0070A
ADAPTER SCREW

M950405-YYY0A
DIVERTER SPOUT (Slip-on)

Replace the "YYY" - "XXX" with


appropriate finish code
CHROME 002
SATIN NICKEL 295
OIL RUBBED BRONZE 224
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1 (800) 442-1902
Weekdays 8:00 a.m. to 8:00 p.m. EST
IN MEXICO 01-800-839-1200

IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)


Weekdays 8:00 a.m. to 7:00 p.m. EST
Product names listed herein are trademarks of American Standard Inc.
© American Standard Inc. 2014 M965625 REV. 1.1 (11/14)