Vous êtes sur la page 1sur 1

Ventialtion Blower Capacity Calculation

Tank Dia in ft 120.00


Roof Height in ft (Maint) 7.00
Volume of enclosed space Cu.ft 79200.00

CFM Determination

No of Charge to be supplied per hr acc to API 5


Total Volume to be supplied per hr 396000.00

No of Fans used 2
CFM to be supplied per fan 3300.00

Velocity determination

Size of the Fan in inch 20.00

Velocity should be measaured m/s 33.00

Fan Reference (Coppus & Prime Blowers Corporation)

CFM can be supplied by 20" blower @ 80 PSI 11000

CFM can be supplied by 24" blower @ 80 PSI 16900

Notes

1 Meter = 3.28 Feet

SCFM = Standard Cubic Feet per minute

Result

Is the Ventilation Safe enough acc to API cons. 20" SAFE


Is the Ventilation Safe enough acc to API cons. 24" SAFE

Recommendation can be made to install 24" Blower if 20" blower is unsafe


provided man Way of 24" is avaiable.