SUNNY HIGHPOWER PEAK1 [SHP 75-10]

TECHNICAL PRESENTATION

SMA Solar Technology AG


WHEN MAXIMUM HAS NO LIMIT
COMPARISON SHP 75-10 VS. STP 60-10

STP 60-10 SHP 75-10


AC power 60 kW/60kVA 75 kW/75kVA
AC nominal voltage 400-480 V (3phase) + PE
Max. efficiency/Euro efficiency 98.8%/98.3% 98.8%/98.2%
Adjustable power factor 0 overexcited to 0 underexcited
Input voltage range 565 - 1000 V
MPP voltage range 570 - 800 V
Number of MPP tracker/rated current/short
1/110A/150A 1x140A/210A
circuit current
CITEL
Surge protection device DC/AC
DC: SPD II/AC: SPD II/III (combined)
Operating temperature range -25°C to 60°C
Weight 75 kg 77 kg
Specific weight 1,25 kg/kW 1.03 kg/kW
Dimensions (WxHxD) 740 x 507 x300 740 x 507 x306
Communication Modbus TCP/IP via Inverter Manager IM-20
Features Limited Export, QonDemand24/7
EMC Class Class B (residential + commercial) Class A (commercial)
Certificates and approvals All relevant MOW countries (missing certificates are available on request)

2
AGENDA

1 Key Facts

2 System Approach

3 Inverter

4 Inverter Manager

5 LCS-Tool

6 DC-Combiner

7 Accessories/Spare parts

3
SUNNY HIGHPOWER PEAK1
TECHNICAL SUMMARY

Product positioning
> The SUNNY HIGHPOWER PEAK1 is the successor of
the SUNNY TRIPOWER 60 system
> With the SHP PEAK1 SMA introduces a new product line
of three phase string inverters for large commercial and
utility scale applications
> The SHP PEAK1 follows the flexible and intelligent system
structure of the well received STP60 which's’ installed base
already exceeded 2 GW in more than50 countries
Technical Data
Power: 75 kWAC
DC voltage: 570 – 1.000 VDC
Efficiency: 98,8 % peak
Weight: 77 kg
Dimensions: 570x740x306 mm

4
SUNNY HIGHPOWER PEAK1
KEY PRODUCT FACTS & BENEFITS

HIGHEST YIELD AND CENTRAL CONTROL WITH


ULTIMATE FLEXIBILITY INVERTER MANAGER
1

FAST COMMISSIONING
MAXIMUM SECURITY AND GREATEST EFFICIENCY
4

100% PEACE OF MIND WITH SMA

5
HIGHEST YIELD AND ULTIMATE FLEXIBILITY
SOLUTION FOR COMMERCIAL AND UTILITY APPLICATIONS

GROUND MOUNT LARGE ROOFTOPS

6
AGENDA

1 Key Facts

2 System Approach

3 Inverter

4 Inverter Manager

5 LCS-Tool

6 DC-Combiner

7 Accessories/Spare parts

7
SMA THREE-PHASE STRING INVERTERS
DIFFERENT PV SYSTEMS REQUIRE DIFFERENT INVERTERS
Sunny Tripower CORE1 (STP50-40) & STP25 Sunny Higpower 75

Core 1
Sunny Tripower CORE1
> highly flexible with smart grid management functions > inverter combines advantages of a string inverter and
> multiple MPP trackers for max. yield with shaded arrays central inverter
/ multiple panel orientations > one MPP tracker and booster-less topology for less
> strings directly connected to the inverter to reduce shaded utility applications with higher inverter
components in the field efficiency

> inverters are distributed in the field > inverters placed centrally in the field to reduce
cabling and installation costs
> direct connection of large AC cables up to allows to
avoid installing AC combiners > DC combiner can be tuned to project-specific needs
(# of strings, features)
provides flexibility for fast realization of stream-lined BOS costs andmaximum
small to medium-scale projects efficiency for large-scale projects
8
HIGHEST YIELD AND ULTIMATE FLEXIBILITY
THE SMART SYSTEM SETUP

Sunny Highpower SMA Inverter DC Combiner Box Medium


PEAK1 Manager Voltage Station

9
FAST COMMISSIONING AND GREATEST EFFICIENCY
SHP PEAK1 MOST COST ATTRACTIVE PLANT DESIGN

Data Management
1 75 kVA SHP DC combiner
SHP
1
Transformerless inverter 1 PC

for commercial and utility Cloud services


PV plants PV array SMA Inverter
SHP Manager
DC combiner
2 Messaging


Utility control
2 SMA Inverter Manager PV array
The central control unit DC combiner
42
SHP
SCADA system
42

PV array

Transformer

10
FAST COMMISSIONING AND GREATEST EFFICIENCY
SHP PEAK1 MOST COST ATTRACTIVE PLANT DESIGN

Thanks to an intelligent system structure, all inverters are installed centrally in one
place, while the DC combiners are distributed in the field

DC-Combiner

Sunny Highpower PEAK1


Transformer
Inverter Manager

The centralized SHP Peak1 plant design leads to cost savings in


• Service & maintenance • Installation/labor
• Communication infrastructure • AC and DC cabling

11
FAST COMMISSIONING AND GREATEST EFFICIENCY
SHP PEAK1 MOST COST ATTRACTIVE PLANT DESIGN

Cost savings in DC cabling thanks to distributed DC-combiners in the field


> Lower cable losses (DC: 1000VDC vs. AC: 400VAC)
> DC-cables are usually cheaper than AC-cables
> Customized DC-Combiner offer tremendous DC connection flexibility

12
FAST COMMISSIONING AND GREATEST EFFICIENCY
SHP PEAK1 MOST COST ATTRACTIVE PLANT DESIGN

Cost savings in infrastructure and installation/labor thanks to centrally placed inverter


> Short communication cables and easy installation
> Short AC-runs
> Simple installation and minimized logistics effort

13
FAST COMMISSIONING AND GREATEST EFFICIENCY
SHP PEAK1 MOST COST ATTRACTIVE PLANT DESIGN

Cost savings in Service & Maintenance thanks centrally placed inverter


> Easy maintenance
> Easy failure observation (e.g. broken communication cable)
> Easy replacement

14
AGENDA

1 Key Facts

2 System Approach

3 Inverter

4 Inverter Manager

5 LCS-Tool

6 DC-Combiner

7 Accessories/Spare parts

15
HIGHEST YIELD AND ULTIMATE FLEXIBILITY
INVERTER SHP PEAK1

Tremendous power density with 75 kW at only 77 kg allows


flexible planning of large PV plants in steps of 75 kW
• Scalable / distributed central inverter in 75kW steps provides highest
flexibility in PV plant design as „off the shelf building blocks“
• High power of the inverter (75kW) with a peak efficiency of 98,8%
reduces amount of inverters to be installed in the plant
• Independent MPPT per inverter – one DC Input leads to higher
efficiency and max. yield at partly shaded sections in commercial &
utility PV plants (compared to central inverter)

Sunny Highpower PEAK1 system combines the advantages of a string


inverter and a central inverter in one device!

16
HIGHEST YIELD AND ULTIMATE FLEXIBILITY
INVERTER SHP PEAK1

General Data
> Output Power: 75kW/75kVA
> Weight: 77kg
> Highest Efficiency: 98.8% (peak), 98.2 (Euro)
> DC/AC ratio up to 150%
> IP 65/NEMA 3R enclosure + coated PCBs and a potted coil box
> Operating temperature from -25°C to 60°C / (-13°F to140°F)
> Max. operating altitude is 2000m above sea level*
*Approval for higher altitudes on demand

> EMC class A for commercial application (future proof: Fulfils


already upcoming EN55011:2017)

17
HIGHEST YIELD AND ULTIMATE FLEXIBILITY
INVERTER SHP PEAK1

DC-Side

> 1 MPPT/ 1 DC input (Mono string)

> No step up converter

> Rated current 140 A/ max short circuit current 210 A

> DC-Input voltage 570* - 1000 V


> Maximum DC/AC ratio: 150%
> Approved DC-cable diameter: 16-150 mm² (AL/CU)

*DC min. depends of the AC voltage level: 570V (400VAC)/685V (480VAC)

18
HIGHEST YIELD AND ULTIMATE FLEXIBILITY
INVERTER SHP PEAK1

AC-Side
> AC voltage ranges: 400 - 480 Volt ( +/- 10% )
> 3 Phases + PE, (no Neutral)

> Grid frequency range 50/60 Hz

> Active/Reactive power

> 0.0 over-exited/ under-exited

> QonDemand 24/7 (Q@Night)

> Grounding scheme supported TN / TT

> Only Star-Center-Ground transformer supported (no delta transformer)

> Approved AC-cable diameter: 16-150mm² (AL/CU)

19
HIGHEST YIELD AND ULTIMATE FLEXIBILITY
INVERTER SHP PEAK1

Active cooling system

> SMA’s active cooling concept with speed controlled fans for long inverter
life and maximum yield over lifetime

> Fans are controlled by sensors and turn on and off according to the
temperature

> Fans are designed for the inverter life time


(The expected fan lifetime [counted in working hours] is 80.000 working
hours @40° and 40.000 working hours @70°C.)

> Fans optimizes the derating behavior at higher temperatures

> In case the cooling channel gets blocked (by foliage, wood or dust) the
fans free-blow the channel

20
HIGHEST YIELD AND ULTIMATE FLEXIBILITY
INVERTER SHP PEAK1

Electrical insulation according to IEC 60742 (PELV)


2 Device grounding
7 Ethernet Port x 2
8 RS-485 Port (not used)
Hazardous live parts
1 AC-Connection Terminals
5 PV-Connection Terminals
Miscellaneous
3 AC-Overvoltage Protection (SPDs)
4 DC-Overvoltage Protection (SPDs)
6 PV-Switch Disconnector

21
HIGHEST YIELD AND ULTIMATE FLEXIBILITY
INVERTER SHP PEAK1

Surge protection devices (SPD)

> Always integrated/pre-installed in every inverter on the AC/DC-side

> Inverter can’t operate without surge protection devices

> Surge protection according to IEC 61643-11 standard

> AC-side: SPD Type II/III combined

> DC-side: SPD Type II

> Wear-out monitoring via Inverter Manager

> Easy replaceable SPD’s ensures cost efficient replacement in case of


damage or wear-out

> High quality “Citel” devices without leakage current

22
HIGHEST YIELD AND ULTIMATE FLEXIBILITY
INVERTER SHP PEAK1

Inverter Display

> Display is read only (no adjustments possible)

> DISPLAY: Main OVERVIEW

> DISPLAY: INVERTER INFO

> DISPLAY: INVERTER SOFTWARE

 DISPLAY: MEASUREMENTS

23
AGENDA

1 Key Facts

2 System Approach

3 Inverter

4 Inverter Manager

5 LCS-Tool

6 DC-Combiner

7 Accessories/Spare parts

24
CENTRAL CONTROL WITH THE INVERTER MANAGER
THE GATEWAY BEETWEEN PLANT AND INVERTER

Combines the system intelligent into one device


> Single point of interface for monitoring and control.
> Mandatory for commissioning, updates and monitoring.
> Inverter data upload to SMA Sunny Portal/FTP push or any 3rd party data
base
> Inverter Manager provides integrated interface for numerous external
devices like weather station, router or I/O-Box
> One single Inverter Manager can serve up to 42x SHP PEAK1 (= 3,15
MVA). For larger PV sites just add easily additional devices accordingly.
> Inverter FW updated centrally via the Inverter Manager/LCS-Tool

25
CENTRAL CONTROL WITH THE INVERTER MANAGER
THE GATEWAY BEETWEEN PLANT AND INVERTER

Inverter Manager Technical Data

> Ruggedized industry PC from MOXA (V2201 series, Linux based OS)
> IP21 rating (additional enclosure for outdoor installation needed)
> DC supply voltage: 9 V to 36V (power consumption <20W).
Recommended power supply: SMA CLCON-PWRSUPPLY
> Operation temperature from -40 to +85°C
> 2 Ethernet interfaces:
> LAN1: Plant Network
> LAN2: Inverter Network
> External communication via Modbus TCP/IP (Sunspec)
> RS-485 interface for weather stations supporting Sunspec RTU (Port1)
> Optional I/O-interface (Port2) e.g. for ripple controll recievers with 6 inputs

26
CENTRAL CONTROL WITH THE INVERTER MANAGER
THE GATEWAY BEETWEEN PLANT AND INVERTER

Weather Station (1)


> Systemintegration via RS485/Modbus RTU (Sunspec Alliance)
> Directly connected to Inverter Manager on Port 1 (for further installation information please refer to the
Inverter Manager installation manual)
> Maximum 1 weather station/2 temperature sensors to be connected to one Inverter Manager

27
CENTRAL CONTROL WITH THE INVERTER MANAGER
THE GATEWAY BEETWEEN PLANT AND INVERTER

Weather Station (2)


> Interface: RS485/Modbus RTU (Sunspec Alliance)
> Supported Baud rate: 9600/19200/57600/115200 Baud
> Approved weather stations by SMA: „Rainwise PVmet-200 and PVmet 75; ABB VSN800-12 and
VSN800-14“**
**Please Note: SMA does not recommend any third-party products. TheLCS-Tool/FTP-Push
Modbus TCP/Sunspec Alliance
decision and responsibility is up to the customer.
SMA Sunny Portal
(via Inverter Manager)

Temperature (ambient/PV)

Wind (speed/direction)

Only in case if inclined irradiation is not available


Horizontal irradiation

Inclined irradiation

28
AGENDA

1 Key Facts

2 System Approach

3 Inverter

4 Inverter Manager

5 LCS-Tool

6 DC-Combiner

7 Accessories/Spare parts

29
HIGHEST YIELD AND ULTIMATE FLEXIBILITY
LCS-TOOL

LCS – TOOL: General Overview


> Local Commissioning and Service Tool for Windows PC’s
> Free of charge, available on SMA’s homepage for download
> SHP 75 Inverter and Inverter Manager firmware are always part of the LCS-Tool
with the corresponding version (for instance Inverter FW 1.90 = LCS-Tool 1.90)
> Only one version can be installed on one computer. The former version (no matter if
higher or lower) will be removed automatically during the installation of the “new”
LCS-Tool
> Higher LCS-Tool versions can work with lower FW-versions on the Inverter Manager,
but not vice versa
> LCS-Tool transfers settings / information to the Inverter Manager, the Inverter
Manager distributes the FW to all connected inverters

30
HIGHEST YIELD AND ULTIMATE FLEXIBILITY
LCS-TOOL

LCS – TOOL: Main features and functionalities


> Easy commissioning/re-commissioning of the PV-plant
> Firmware update of the Inverter Manager and connected inverters
> Access to / download of event logs and data logs for each SHP 75 inverter
> Export plant/inverter reports
> Add, remove or replace inverters (including recommissioning of the corresponding
inverter)
> Set FTP uploads or Sunny Portal registration
> Enable and configure Fallback Modes, Limited Export function, weather station etc.
> Adjust inverter and plant parameter
> Monitoring and control of power generation, -limitation and network communication

31
AGENDA

1 Key Facts

2 System Approach

3 Inverter

4 Inverter Manager

5 LCS-Tool

6 DC-Combiner

7 Accessories/Spare parts

32
HIGHEST YIELD AND ULTIMATE FLEXIBILITY
FLEXIBLE DC COMBINER FOR INDIVIDUAL STRINGING

Full flexibility through free choice of customized


DC Combiners
> Number of string inputs is not limited by the inverter
> Maximize your return of investment by selecting your optimum
DC/AC ratio with a fully flexible number of strings
> SMA’s product portfolio contains customized combiner boxes
for individual plant design:
> Fuses (single or dual)
> With/without DC switch
> With/without over voltage protection (acc. Class 2, EN 50539-11)
> With/without string monitoring (on demand)
> Individual number of string inputs (12/14/16/18)

33
DC-COMBINER BOX
FLEXIBLE DC COMBINER FOR INDIVIDUAL STRINGING

DC-Combiner Box
> More than 20 different variants available (please refer to the current pricelist)
> Country specific variants: MOW/IEC and JP
> Supplier: Phoenix Contact and other high quality supplier
> Fuses are not included in scope of delivery for MOW version, but can be ordered separately by SMA

Supplier Size [A] Mat. Nr. Listprice [€]/10pcs Notes


Phoenix Contact 15 DC-CMB-CFP1015.01 14,- Packaging unit 10 pcs

Supplier Size [A] Mat. Nr. Listprice [€]/10pcs Notes


Littlefuse 12 DC-CMB-UFP1012.01 19,-
Packaging unit 10 pcs
Littlefuse 20 DC-CMB-UFP1020.01 19,-

> SHP 75 can also be connected to any other 3rd party DC-combiner, as long as the technical parameter
stay within the specification (cable size, current, voltage, ambient condition)