Vous êtes sur la page 1sur 8

Project Job Ref.

Precast Wall -02 Modification at WR 503


Section Sheet no./rev.
VA-342547 1 02
Calc. by Date Chk'd by Date App'd by Date
JJP 10/9/2018 FHG 10/10/2018

STEEL MEMBER ANALYSIS & DESIGN (EN1993-1-1:2005)


In accordance with EN1993-1-1:2005 incorporating Corrigenda February 2006 and April 2009 and the recommended
values
Tedds calculation version 4.2.00

ANALYSIS
Tedds calculation version 1.0.18

Geometry
Geometry (m) - Steel (EC3) - HP 200x53
Z
1 4.86 2
X
1

Material - Steel (EC3)


Density 7850 kg/m3 Youngs Modulus 210 kN/mm2
Shear Modulus 80.8 kN/mm2 Thermal Coefficient 0.000012 C-1

Section type - HP 200x53


Area 68 cm2
Major moment of inertia 4950 cm4 Shear area Ay 42 cm2
4
Minor moment of inertia 1680 cm Shear area Az 23 cm2

Support conditions
Support 1 X Fixed Z Fixed Rotationally Fixed
Support 2 X Fixed Z Fixed Rotationally Fixed

Spans
Span 1 4.86 m

Loading
Self Weight - Loading (kN/m)
0.53

0.53

Imposed - Loading (kN/m,kN)


7.64

7.64

X 200

Load combination factors


Project Job Ref.
Precast Wall -02 Modification at WR 503
Section Sheet no./rev.
VA-342547 2 02
Calc. by Date Chk'd by Date App'd by Date
JJP 10/9/2018 FHG 10/10/2018

Self Weight

Imposed
Load combination

1.35G + 1.5Q + 1.5RQ (Strength) 1.70 1.40


1.0G + 1.0Q + 1.0RQ (Service) 1.00
Node loads
Node Load case Force Moment
X Z
(kN) (kN) (kNm)
2 Imposed -200 0 0
Member UDL loads
Member Load case Position Load Orientation
Type Start End
(kN/m)
Beam Imposed Ratio 0 1 7.64 GlobalZ

Results
Total deflection
1.35G + 1.5Q + 1.5RQ (Strength) - Total deflection
1 2
X

Member results
Load combination: 1.35G + 1.5Q + 1.5RQ (Strength)
Member Deflection Axial deflection
Pos Max Pos Min Pos Max Pos Min
(m) (mm) (m) (mm) (m) (mm) (m) (mm)
Beam 2.43 1.7 4.86 0 0 0 0 0
1.0G + 1.0Q + 1.0RQ (Service) - Total deflection
1 2
X

Member results
Load combination: 1.0G + 1.0Q + 1.0RQ (Service)
Member Deflection Axial deflection
Pos Max Pos Min Pos Max Pos Min
(m) (mm) (m) (mm) (m) (mm) (m) (mm)
Beam 2.43 1.1 4.86 0 0 0 0 0
Project Job Ref.
Precast Wall -02 Modification at WR 503
Section Sheet no./rev.
VA-342547 3 02
Calc. by Date Chk'd by Date App'd by Date
JJP 10/9/2018 FHG 10/10/2018

Node deflections
Load combination: 1.35G + 1.5Q + 1.5RQ (Strength)
Node Deflection Rotation Co-ordinate
system
X Z
(mm) (mm) ()
1 0 0 0 Beam
2 0 0 0 Beam
Load combination: 1.0G + 1.0Q + 1.0RQ (Service)
Node Deflection Rotation Co-ordinate
system
X Z
(mm) (mm) ()
1 0 0 0 Beam
2 0 0 0 Beam
Total base reactions
Load case/combination Force
FX FZ
(kN) (kN)
1.35G + 1.5Q + 1.5RQ (Strength) 280 56.3
1.0G + 1.0Q + 1.0RQ (Service) 200 37.1
Reactions
1.35G + 1.5Q + 1.5RQ (Strength) - Local node reactions - Node: (Horiz (kN), Vert (kN), Mom (kNm))
1: (0,28.2,-22.8) 2: (280,28.2,22.8)

Load combination: 1.35G + 1.5Q + 1.5RQ (Strength)


Node Force Moment
Fx Fz My
(kN) (kN) (kNm)
1 0 28.2 -22.8
2 280 28.2 22.8
1.0G + 1.0Q + 1.0RQ (Service) - Local node reactions - Node: (Horiz (kN), Vert (kN), Mom (kNm))
1: (0,18.6,-15) 2: (200,18.6,15)

Load combination: 1.0G + 1.0Q + 1.0RQ (Service)


Node Force Moment
Fx Fz My
(kN) (kN) (kNm)
1 0 18.6 -15
2 200 18.6 15
Project Job Ref.
Precast Wall -02 Modification at WR 503
Section Sheet no./rev.
VA-342547 4 02
Calc. by Date Chk'd by Date App'd by Date
JJP 10/9/2018 FHG 10/10/2018

Element end forces


Load combination: 1.35G + 1.5Q + 1.5RQ (Strength)
Element Length Nodes Axial force Shear force Moment
(m) Start/End (kN) (kN) (kNm)
1 4.86 1 0 -28.2 22.8
2 0 -28.2 -22.8
Load combination: 1.0G + 1.0Q + 1.0RQ (Service)
Element Length Nodes Axial force Shear force Moment
(m) Start/End (kN) (kN) (kNm)
1 4.86 1 0 -18.6 15
2 0 -18.6 -15
Forces
Strength combinations - Moment envelope (kNm)
-22.8

11.4

Strength combinations - Shear envelope (kN)


28.2

-28.2

Service combinations - Deflection envelope (mm)

1.1

Member results
Envelope - Strength combinations
Member Shear force Moment
Pos Max abs Pos Max Pos Min
(m) (kN) (m) (kNm) (m) (kNm)
Beam 4.86 -28.2 2.43 11.4 4.86 -22.8
Project Job Ref.
Precast Wall -02 Modification at WR 503
Section Sheet no./rev.
VA-342547 5 02
Calc. by Date Chk'd by Date App'd by Date
JJP 10/9/2018 FHG 10/10/2018

Envelope - Service combinations


Member Deflection
Pos Max Pos Min
(m) (mm) (m) (mm)
Beam 2.43 1.1 4.86 0
1.35G + 1.5Q + 1.5RQ (Strength) - Moment (kNm)
-22.8 -22.8

11.4

1.35G + 1.5Q + 1.5RQ (Strength) - Shear (kN)


28.2

-28.2

Member results
Load combination: 1.35G + 1.5Q + 1.5RQ (Strength)
Member Shear force Moment
Pos Max abs Pos Max Pos Min
(m) (kN) (m) (kNm) (m) (kNm)
Beam 4.86 -28.2 2.43 11.4 4.86 -22.8
1.0G + 1.0Q + 1.0RQ (Service) - Deflection (mm)
0

1.1

Member results
Load combination: 1.0G + 1.0Q + 1.0RQ (Service)
Member Deflection
Pos Max Pos Min
(m) (mm) (m) (mm)
Beam 2.43 1.1 4.86 0
;
Project Job Ref.
Precast Wall -02 Modification at WR 503
Section Sheet no./rev.
VA-342547 6 02
Calc. by Date Chk'd by Date App'd by Date
JJP 10/9/2018 FHG 10/10/2018

Partial factors - Section 6.1


Resistance of cross-sections; M0 = 1
Resistance of members to instability; M1 = 1
Resistance of tensile members to fracture; M2 = 1.25

Beam design
Section details
Section type; HP 200x53 (AISC 14th Edn (v14.1))
Steel grade - EN 10025-2:2004; S275
Nominal thickness of element; tnom = max(tf, tw) = 11.3 mm
Nominal yield strength; fy = 275 N/mm2
Nominal ultimate tensile strength; fu = 410 N/mm2
Modulus of elasticity; E = 210000 N/mm2
11.3

HP 200x53 (AISC 14th Edn (v14.1))


Section depth, h, 204 mm
Section breadth, b, 207 mm
Mass of section, Mass, 53 kg/m
Flange thickness, tf, 11.3 mm
Web thickness, tw, 11.3 mm
Root radius, r, 17.4 mm
Area of section, A, 6840 mm2
Radius of gyration about y-axis, iy, 85.3 mm
204

Radius of gyration about z-axis, iz, 49.5 mm


Elastic section modulus about y-axis, Wel.y, 488000 mm3
Elastic section modulus about z-axis, Wel.z, 162000 mm3
11.3 Plastic section modulus about y-axis, Wpl.y, 551000 mm3
Plastic section modulus about z-axis, Wpl.z, 249000 mm3
Second moment of area about y-axis, Iy, 49500000 mm4
Second moment of area about z-axis, Iz, 16800000 mm4
11.3

207

Lateral restraint
Both flanges have lateral restraint at supports plus 3250 mm

Consider Combination 1 - 1.35G + 1.5Q + 1.5RQ (Strength)


Classification of cross sections - Section 5.5
 = [235 N/mm2 / fy] = 0.92

Internal compression parts subject to bending - Table 5.2 (sheet 1 of 3)


Width of section; c = d = 146.6 mm
c / tw = 13 = 14   <= 72  ; Class 1

Outstand flanges - Table 5.2 (sheet 2 of 3)


Width of section; c = (b - tw - 2  r) / 2 = 80.5 mm
c / tf = 7.1 = 7.7   <= 9  ; Class 1
Section is class 1

Check design at start of span


Check shear - Section 6.2.6
Height of web; hw = h - 2  tf = 181.4 mm;  = 1.200
Project Job Ref.
Precast Wall -02 Modification at WR 503
Section Sheet no./rev.
VA-342547 7 02
Calc. by Date Chk'd by Date App'd by Date
JJP 10/9/2018 FHG 10/10/2018

hw / tw = 16.1 = 20.8   /  < 72   / 


Shear buckling resistance can be ignored
Design shear force; Vy,Ed = 28.2 kN
Shear area - cl 6.2.6(3); Av = max(A - 2  b  tf + (tw + 2  r)  tf,   hw  tw) = 2683 mm2
Design shear resistance - cl 6.2.6(2); Vc,y,Rd = Vpl,y,Rd = Av  (fy / (3)) / M0 = 425.9 kN
Vy,Ed / Vc,y,Rd = 0.066
PASS - Design shear resistance exceeds design shear force
Check bending moment - Section 6.2.5
Design bending moment; My,Ed = 22.8 kNm
Design bending resistance moment - eq 6.13; Mc,y,Rd = Mpl,y,Rd = Wpl.y  fy / M0 = 151.5 kNm
My,Ed / Mc,y,Rd = 0.151
PASS - Design bending resistance moment exceeds design bending moment
Slenderness ratio for lateral torsional buckling
Correction factor - Table 6.6; kc = 0.614
C1 = 1 / kc2 = 2.652
Poissons ratio;  = 0.3
Shear modulus; G = E / [2  (1 + )] = 80769 N/mm2
Unrestrained effective length; L = 1.0  Lm1_s1_seg1_B = 3250 mm
Elastic critical buckling moment; Mcr = C1  2  E  Iz / L2  (Iw / Iz + L2  G  It / (2  E  Iz)) = 1141.9 kNm
Slenderness ratio for lateral torsional buckling; LT = (Wpl.y  fy / Mcr) = 0.364
Limiting slenderness ratio; LT,0 = 0.4
LT <LT,0 - Lateral torsional buckling can be ignored

Check design 2430 mm along span


Check bending moment - Section 6.2.5
Design bending moment; My,Ed = 11.4 kNm
Design bending resistance moment - eq 6.13; Mc,y,Rd = Mpl,y,Rd = Wpl.y  fy / M0 = 151.5 kNm
My,Ed / Mc,y,Rd = 0.075
PASS - Design bending resistance moment exceeds design bending moment
Slenderness ratio for lateral torsional buckling
Correction factor - Table 6.6; kc = 0.614
C1 = 1 / kc2 = 2.652
Poissons ratio;  = 0.3
Shear modulus; G = E / [2  (1 + )] = 80769 N/mm2
Unrestrained effective length; L = 1.0  Lm1_s1_seg1_T = 3250 mm
Elastic critical buckling moment; Mcr = C1  2  E  Iz / L2  (Iw / Iz + L2  G  It / (2  E  Iz)) = 1141.9 kNm
Slenderness ratio for lateral torsional buckling; LT = (Wpl.y  fy / Mcr) = 0.364
Limiting slenderness ratio; LT,0 = 0.4
LT <LT,0 - Lateral torsional buckling can be ignored

Check design at end of span


Check shear - Section 6.2.6
Height of web; hw = h - 2  tf = 181.4 mm;  = 1.200
Project Job Ref.
Precast Wall -02 Modification at WR 503
Section Sheet no./rev.
VA-342547 8 02
Calc. by Date Chk'd by Date App'd by Date
JJP 10/9/2018 FHG 10/10/2018

hw / tw = 16.1 = 20.8   /  < 72   / 


Shear buckling resistance can be ignored
Design shear force; Vy,Ed = 28.2 kN
Shear area - cl 6.2.6(3); Av = max(A - 2  b  tf + (tw + 2  r)  tf,   hw  tw) = 2683 mm2
Design shear resistance - cl 6.2.6(2); Vc,y,Rd = Vpl,y,Rd = Av  (fy / (3)) / M0 = 425.9 kN
Vy,Ed / Vc,y,Rd = 0.066
PASS - Design shear resistance exceeds design shear force
Check bending moment - Section 6.2.5
Design bending moment; My,Ed = 22.8 kNm
Design bending resistance moment - eq 6.13; Mc,y,Rd = Mpl,y,Rd = Wpl.y  fy / M0 = 151.5 kNm
My,Ed / Mc,y,Rd = 0.151
PASS - Design bending resistance moment exceeds design bending moment
Slenderness ratio for lateral torsional buckling
Correction factor - Table 6.6; kc = 0.602
C1 = 1 / kc2 = 2.756
Poissons ratio;  = 0.3
Shear modulus; G = E / [2  (1 + )] = 80769 N/mm2
Unrestrained effective length; L = 1.0  Lm1_s1_seg2_B = 1610 mm
Elastic critical buckling moment; Mcr = C1  2  E  Iz / L2  (Iw / Iz + L2  G  It / (2  E  Iz)) = 3909.1 kNm
Slenderness ratio for lateral torsional buckling; LT = (Wpl.y  fy / Mcr) = 0.197
Limiting slenderness ratio; LT,0 = 0.4
LT <LT,0 - Lateral torsional buckling can be ignored

Check design 2430 mm along span


Check y-y axis deflection - Section 7.2.1
Maximum deflection; y = 1.7 mm
Allowable deflection; y,Allowable = Min(Lm1_s1 / 360, 15 mm) = 13.5 mm
y / y,Allowable = 0.127
PASS - Allowable deflection exceeds design deflection