The purpose of this table is to provide a

quick determination of the "worst case" The Rule for line spacing is: Flange-to-pipe
distance a flange extends beyond the Quick Worst Case Flange Extension Chart plus and inch. For the flange you should
pipe O. D. for use during pipe line use the worst case.
spacing

All Ratings 150# 300# 400# 600# 900# 1500# 2500#


Nominal Size

Flange O. D.

Flange O. D.
Flange O. D.

Flange O. D.

Flange O. D.

Flange O. D.

Flange O. D.
Extension

Extension

Extension

Extension

Extension

Extension

Extension
Actual Pipe

(Inches)

(Inches)

(Inches)

(Inches)

(Inches)

(Inches)

(Inches)
(Inches)
Flange

Flange

Flange
Flange

Flange

Flange

Flange
O. D.

3 3.500 7.500 2.000 ### 8.250 2.375 ### (use 600#) ### 8.250 2.375 ### 9.500 3.000 ###10.500 3.500 ###12.000 4.250
4 4.500 9.000 2.250 ### 10.000 2.750 ### 10.000 2.750 ###10.750 3.125 ###11.500 3.500 ###12.250 3.875 ###14.000 4.750
6 6.625 11.000 2.188 ### 12.500 2.938 ### 12.500 2.938 ###14.000 3.688 ###15.000 4.188 ###15.500 4.438 ###19.000 6.188
8 8.625 13.500 2.438 ### 15.000 3.188 ### 15.000 3.188 ###16.500 3.938 ###18.500 4.938 ###19.000 5.188 ###21.750 6.563
10 10.750 16.000 2.625 ### 17.500 3.375 ### 17.500 3.375 ###20.000 4.625 ###21.500 5.375 ###23.000 6.125 ###26.500 7.875
12 12.750 19.000 3.125 ### 20.500 3.875 ### 20.500 3.875 ###22.000 4.625 ###24.000 5.625 ###26.500 6.875 ###30.000 8.625
14 14.000 21.000 3.500 ### 23.000 4.500 ### 23.000 4.500 ###23.750 4.875 ###25.250 5.625 ###29.500 7.750 ###
16 16.000 23.500 3.750 ### 25.500 4.750 ### 25.500 4.750 ###27.000 5.500 ###27.750 5.875 ###32.500 8.250 ###
18 18.000 25.000 3.500 ### 28.000 5.000 ### 28.000 5.000 ###29.250 5.625 ###31.000 6.500 ###36.000 9.000 ###
20 20.000 27.500 3.750 ### 30.500 5.250 ### 30.500 5.250 ###32.000 6.000 ###33.750 6.875 ###38.750 9.375 ###
22 22.000 29.500 3.750 ### 33.000 5.500 ### 33.000 5.500 ###34.250 6.125 ### ### ###
24 24.000 32.000 4.000 ### 36.000 6.000 ### 36.000 6.000 ###37.000 6.500 ###41.000 8.500 ###46.000 11.000 ###
26 26.000 34.250 4.125 ### 38.250 6.125 ### 38.250 6.125 ###40.000 7.000 ### ### ###
30 30.000 38.750 4.375 ### 43.000 6.500 ### 43.000 6.500 ###44.500 7.250 ### ### ###
34 34.000 43.750 4.875 ### 47.500 6.750 ### 47.500 6.750 ###49.000 7.500 ### ### ###
36 36.000 46.000 5.000 ### 50.000 7.000 ### 50.000 7.000 ###51.750 7.875 ### ### ###
42 40.000 53.000 6.500 ### 57.000 8.500 ### 57.000 8.500 ###58.750 9.375 ### ### ###

Green fields
are for user
entry
Large line Flange diameter = 0.000 Inches
Small line Pipe O. D. = 0.000 Inches
CASE A

Using the flange diameter for Minimum Clearance = 0.000 Inches


the larger line and the outdide
diameter of the smallest line. Insulation (if any) on the flange = 0.000 Inches
Insulation (if any) on small line = 0.000 Inches
Total line spacing (before round off) = 0.000 Inches

Smaller line (high pressure) Flange


0.000 Inches
diameter =
CASE B

Using the flange diameter for Large line Pipe O. D. = 0.000 Inches
the smaller, higher flange
rating line and the outdide Minimum Clearance = 0.000 Inches
diameter of the larger line. Insulation (if any) on the flange = 0.000 Inches
Insulation (if any) on small line = 0.000 Inches
Total line spacing (before round off) = 0.000 Inches
Metric

The purpose of this table is to provide a


The Rule for line spacing is: Flange-to-pipe plus
quick determination of the "worst case"
distance a flange extends beyond the pipe Quick Worst Case Flange Extension Chart (Metric) and inch. For the flange you should use the
worst case.
O. D. for use during pipe line spacing
All Ratings 150# 300# 400# 600# 900# 1500# 2500#

Extension (mm)

Extension (mm)

Extension (mm)
Extension (mm)

Extension (mm)

Extension (mm)

Extension (mm)
O.

O.

O.

O.

O.

O.

O.
Nominal Size

O. D. (mm)
Actual Pipe

D. (mm)

D. (mm)

D. (mm)

D. (mm)

D. (mm)
D. (mm)

D. (mm)
Flange
Flange

Flange

Flange

Flange

Flange

Flange
(mm)

Flange

Flange

Flange

Flange

Flange

Flange

Flange
76.20 88.900 191.000 51.050 ### 210.000 60.550 ###210.000 60.550 ### 210.000 60.550 ### 241.000 76.050 ### 267.000 89.050 ### 305.000 108.050
101.60 114.300 229.000 57.350 ### 254.000 69.850 ###254.000 69.850 ### 273.000 79.350 ### 292.000 88.850 ### 311.000 98.350 ### 356.000 120.850
152.40 168.280 279.000 55.360 ### 318.000 74.860 ###318.000 74.860 ### 356.000 93.860 ### 381.000 106.360### 394.000 112.860### 483.000 157.360
203.20 219.080 343.000 61.960 ### 381.000 80.960 ###381.000 80.960 ### 419.000 99.960 ### 470.000 125.460### 483.000 131.960### 552.000 166.460
254.00 273.050 406.000 66.475 ### 445.000 85.975 ###445.000 85.975 ### 508.000 117.475 ### 546.000 136.475### 584.000 155.475### 673.000 199.975
304.80 323.850 483.000 79.575 ### 521.000 98.575 ###521.000 98.575 ### 559.000 117.575 ### 610.000 143.075### 673.000 174.575### 762.000 219.075
355.60 355.600 533.000 88.700 ### 584.000 114.200###584.000 114.200### 603.000 123.700 ### 641.000 142.700### 749.000 196.700###
406.40 406.400 597.000 95.300 ### 648.000 120.800###648.000 120.800### 686.000 139.800 ### 705.000 149.300### 826.000 209.800###
457.20 457.200 635.000 88.900 ### 711.000 126.900###711.000 126.900### 743.000 142.900 ### 787.000 164.900### 914.000 228.400###
508.00 508.000 699.000 95.500 ### 775.000 133.500###775.000 133.500### 813.000 152.500 ### 857.000 174.500### 984.000 238.000###
609.60 609.600 813.000 101.700 ### 914.000 152.200###914.000 152.200### 940.000 165.200 ###1041.000 215.700###1168.000 279.200###

Green fields
for user
entry
Large line Flange diameter = 0.000 millimeters
Small line Pipe O. D. = 0.000 millimeters
CASE A

Using the flange diameter for the Minimum Clearance = 0.000 millimeters
larger line and the outside
diameter of the smallest line. Insulation (if any) on the flange = 0.000 millimeters
Insulation (if any) on small line = 0.000 millimeters
Total line spacing (before round off) = 0.000 millimeters

Small line (high pressure) Flg diameter = 0.000 millimeters


Large line Pipe O. D. = 0.000 millimeters
CASE B

Using the flange diameter for the


smaller, higher flange rating line Minimum Clearance = 0.000 millimeters
and the outside diameter of the Insulation (if any) on the flange = 0.000 millimeters
larger line. Insulation (if any) on small line = 0.000 millimeters
Total line spacing (before round off) = 0.000 millimeters