Académique Documents
Professionnel Documents
Culture Documents
UNIVERSIDAD CONTINENTAL
ING. DE CIMENTACIONES
Investigación:
INTEGRANTES:
MARCA SOTOMAYOR, Cesar
MORALES GUILLEN, Marisela
PEREZ CALIXTO, Kevin
ROMÁN LIZARBE, Royer
SECCIÓN:
2018-01
2018-01
INDICE
INTRODUCCIÓN ........................................................................................................................................ 3
I. UBICACIÓN ........................................................................................................................................ 4
II. GENERALIDADES ............................................................................................................................... 4
III. CUADRO DE AREAS ......................................................................................................................... 5
IV. SOLUCION ADOPTADA ............................................................................................................... 5
A. AGUA POTABLE: ................................................................................................................................ 5
V. CALCULOS AGUA FRIA ................................................................................................................... 6
A. CALCULO DE DOTACION DE AGUA .................................................................................................... 6
B. CALCULO DE VOLUMEN DEL TANQUE CISTERNA (TC) Y TANQUE ELEVADO (TE) ............................. 7
C. DIMENSIONES DEL TANQUE CISTENA ............................................................................................... 8
D. DIMENSIONES DEL TANQUE ELEVADO .............................................................................................. 9
E. ALTURA DE TANQUE ELEVADO........................................................................................................ 10
F. SELECCIÓN DE LA BOMBA ............................................................................................................... 12
VI. REDES DE DESAGUE .................................................................................................................... 13
A. COLECOTRES .................................................................................................................................... 13
B. MONTANTES .................................................................................................................................... 15
C. REGISTROS ....................................................................................................................................... 16
D. CAJAS DE REGISTROS ....................................................................................................................... 17
VII. VENTILACION ............................................................................................................................... 18
A. MONTANTE...................................................................................................................................... 19
INSTALACIONES SANITARIAS
2018-01
INTRODUCCIÓN
INSTALACIONES SANITARIAS
2018-01
I. UBICACIÓN
Mza. “B”, Lote “12”, Calle PARACAS,
URB. LA ESTANCIA, DISTRITO DE PUEBLO LIBRE
DISTRITO Y PROVINCIA DE LIMA
II. GENERALIDADES
INSTALACIONES SANITARIAS
2018-01
A. AGUA POTABLE:
INSTALACIONES SANITARIAS
2018-01
o 5 pisos en total
o 4 pisos destinados a vivienda multifamiliar
o 1er piso (2 estacionamientos, sala de espera)
o 1 departamento por cada piso
o 3 dormitorios por piso
INSTALACIONES SANITARIAS
2018-01
3
Vcisterna = xdotacion diaria
4
3
Vcisterna = x5540 litros/dia
4
Vcisterna = 4.2 𝑚3
INSTALACIONES SANITARIAS
2018-01
1
Velevado = xdotacion diaria
3
1
Velevado = x5540 litros/dia
3
Velevado = 1.9 𝑚3
COMPROBACIÓN:
𝑎 1 ℎ 2
𝑎 = 3𝑘
= y = 𝑙 = 6𝑘
𝑙 2 𝑙 3
ℎ = 4𝑘
INSTALACIONES SANITARIAS
2018-01
4.2𝑚3 = 𝑎𝑥𝑙𝑥ℎ
Reemplazando tenemos:
𝑘 = 0.40
𝑎 = 1.2𝑚
𝑙 = 2.4𝑚
ℎ = 1.6 + 0.30 = 1.90 𝑚
Velevado = 1.90𝑚3
𝑎 = 1.3𝑚
𝑙 = 1.3𝑚
ℎ = 1.3𝑚
INSTALACIONES SANITARIAS
2018-01
INSTALACIONES SANITARIAS
LONGITUDES EQUIVALENTES LONGITUD LONGITUD PERDIDA
Q DN Di V NPT PRESION
TRAMO UH CODO TE CONTR. ENSANC. VALV. TRAMO EQUIVALEN CARGA
(lps) (mm) (mm) (m/seg) N° Le N° Le N° Le N° Le N° Le RECTO TE TOTAL (m) (m) (m.c.a)
ab 27.00 0.69 33.00 29.40 1.02 3.00 1.02 1.00 0.30 1.00 4.37 0.20 0.30 0.30
bc 15.00 0.44 33.00 29.40 0.65 1.00 1.70 0.70 2.40 0.05 0.00 0.30
ch 4.00 0.16 33.00 29.40 0.24 2.00 0.50 1.00 1.40 1.00 0.20 1.10 3.70 0.01 0.30 0.50
hi 3.00 0.12 33.00 29.40 0.18 2.00 0.50 1.00 1.00 1.20 3.20 0.01 0.20 0.75
hj 1.00 0.08 33.00 29.40 0.12 2.00 0.50 0.80 1.80 0.00 0.55 0.55
bk 12.00 0.38 33.00 29.40 0.56 1.00 1.70 1.20 2.90 0.04 0.00 0.30
kl 6.00 0.25 33.00 29.40 0.37 2.00 0.50 1.00 1.40 1.00 0.20 1.38 3.98 0.03 0.30 0.50
im 3.00 0.12 33.00 29.40 0.18 1.00 0.50 1.00 1.43 1.53 3.46 0.01 0.20 2.00
in 1.00 0.08 33.00 29.40 0.12 1.00 0.50 2.27 2.77 0.00 1.80 2.35
iñ 2.00 0.08 21.00 17.40 0.34 1.00 0.50 1.10 1.60 0.02 0.55 0.55
cd 11.00 0.40 33.00 29.40 0.59 1.00 1.40 1.20 2.60 0.04 0.00 1.00
dd´ 3.00 0.12 21.00 17.40 0.50 2.00 0.50 1.80 2.80 0.06 1.00 1.00
ds 8.00 0.29 21.00 17.40 1.22 1.00 0.50 1.76 2.26 0.26 0.00 1.20
sf 4.00 0.16 33.00 29.40 0.24 2.00 0.50 1.00 1.00 1.80 3.80 0.01 1.20 1.70
sg 4.00 0.16 21.00 17.40 0.67 1.00 0.50 1.00 1.50 0.06 0.50 0.80
kt 6.00 0.25 33.00 29.40 0.37 1.00 0.70 1.00 0.20 1.00 1.90 0.01 0.30 0.85
tp 1.00 0.08 21.00 17.40 0.34 2.00 0.50 1.00 1.00 1.50 3.50 0.04 0.55 0.55
tu 5.00 0.23 33.00 29.40 0.34 1.00 0.50 1.00 1.00 1.00 2.50 0.01 0.00 0.20
uq 3.00 0.12 21.00 17.40 0.50 2.00 0.50 1.28 2.28 0.05 0.20 2.00
ur 2.00 0.08 33.00 29.40 0.12 1.00 0.50 1.50 2.00 0.00 1.80 1.80
0.92
2018-01
CALCULO DE LA ALTURA DEL TANQUE ELEVADO
DATOS
L = 7.87+0.9=8
Q = 0.38 l/s
Dint = 19.381 mm
𝑄 1.85
𝐻𝑓 = 1.18 ∗ 1010 ∗ 𝐿 ∗ ( ) ∗ 𝐷𝑖𝑛𝑡 −4.87
140
Hf = 0.43
H tanque = Hf + hca + hducha + hfmedidor - helevacion
H tanque = 0.43 +2 + 1.6 + 1.8 - 2.5
H tanque = 3.33
H tanque = 3.40
F. SELECCIÓN DE LA BOMBA
2018-01
2018-01
A. COLECOTRES
Es la tubería colocada por debajo del piso, destinada a recibir
y conducir los desagües de todas las partes de la vivienda
hacia el tubo colector público. También se le llama tubo
principal. Generalmente es de PVC y tiene 4 pulgadas
de diámetro. Ha de colocarse con una pendiente (inclinación)
mínima de 1,5 a 2 % (1,5 – 2 cm por metro) para permitir que el
desagüe pase con una buena velocidad hacia la parte
exterior de la vivienda.
INSTALACIONES SANITARIAS
2018-01
DESAGUE
UNIDADES DE DESCARGA
APARATOS SANITARIOS 2° NIVEL 3° NIVEL 4° NIVEL 5° NIVEL TOTAL
INODORO 4.00 4.00 4.00 4.00
LAVATORIO 2.00 2.00 2.00 2.00
DUCHA 2.00 2.00 2.00 2.00
64.00
INODORO 4.00 4.00 4.00 4.00
LAVATORIO 2.00 2.00 2.00 2.00
DUCHA 2.00 2.00 2.00 2.00
INODORO 4.00 4.00 4.00 4.00
LAVATORIO 2.00 2.00 2.00 2.00
DUCHA 2.00 2.00 2.00 2.00
COCINA
56.00
LAVADERO 2.00 2.00 2.00 2.00
PATIO DE SERVICIO
LAVATORIO 2.00 2.00 2.00 2.00
LAVANDERIA 2.00 2.00 2.00 2.00
INSTALACIONES SANITARIAS
2018-01
B. MONTANTES
DESAGUE
UNIDADES DE DESCARGA
APARATOS SANITARIOS 2° NIVEL 3° NIVEL 4° NIVEL 5° NIVEL TOTAL
INODORO 4.00 4.00 4.00 4.00
LAVATORIO 2.00 2.00 2.00 2.00
DUCHA 2.00 2.00 2.00 2.00
64.00
INODORO 4.00 4.00 4.00 4.00
LAVATORIO 2.00 2.00 2.00 2.00
DUCHA 2.00 2.00 2.00 2.00
INODORO 4.00 4.00 4.00 4.00
LAVATORIO 2.00 2.00 2.00 2.00
DUCHA 2.00 2.00 2.00 2.00
COCINA
56.00
LAVADERO 2.00 2.00 2.00 2.00
PATIO DE SERVICIO
LAVATORIO 2.00 2.00 2.00 2.00
LAVANDERIA 2.00 2.00 2.00 2.00
INSTALACIONES SANITARIAS
2018-01
C. REGISTROS
REGISTRO ROSCADO DE 2”
INSTALACIONES SANITARIAS
2018-01
D. CAJAS DE REGISTROS
La instalación de cajas de registro en las redes exteriores en
todo cambio de dirección, pendiente, material o diámetro y
cada 15 m, de largo como máximo, en tramos rectos.
INSTALACIONES SANITARIAS
2018-01
VII. VENTILACION
Permite el ingreso de aire del exterior por medio de un tubo de PVC
que sobresale en la parte superior de la vivienda, generalmente de
2 pulgadas. Así se eliminan los gases y el mal olor producidos por el
desagüe en las tuberías. Otra función importante de este tubo es
permitir la circulación del desagüe con una mayor rapidez. Si la
vivienda no contara con el tubo de ventilación, la red de desagüe
tendría dificultades para eliminar las aguas servidas de la vivienda y
se producirían atoros.
INSTALACIONES SANITARIAS
2018-01
A. MONTANTE
VENTILACION
UNIDADES DE DESCARGA
APARATOS SANITARIOS 2° NIVEL 3° NIVEL 4° NIVEL 5° NIVEL TOTAL
INODORO 4.00 4.00 4.00 4.00
MONTANTE N°01 LAVATORIO 2.00 2.00 2.00 2.00 32.00
DUCHA 2.00 2.00 2.00 2.00
INODORO 4.00 4.00 4.00 4.00
MONTANTE N°02 LAVATORIO 2.00 2.00 2.00 2.00 32.00
DUCHA 2.00 2.00 2.00 2.00
INODORO 4.00 4.00 4.00 4.00
MONTANTE N°03 LAVATORIO 2.00 2.00 2.00 2.00 32.00
DUCHA 2.00 2.00 2.00 2.00
COCINA
LAVADERO 2.00 2.00 2.00 2.00
MONTANTE N°04 PATIO DE SERVICIO 24.00
LAVATORIO 2.00 2.00 2.00 2.00
LAVANDERIA 2.00 2.00 2.00 2.00
INSTALACIONES SANITARIAS
2018-01
INSTALACIONES SANITARIAS