American Association State

Designation: C 138/C 138M – 09 Highway and Transportation Officials Standard


AASHTO No.: T121

Standard Test Method for


Density (Unit Weight), Yield, and Air Content (Gravimetric)
of Concrete1
This standard is issued under the fixed designation C 138/C 138M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.

1. Scope* C 172 Practice for Sampling Freshly Mixed Concrete


1.1 This test method covers determination of the density C 173/C 173M Test Method for Air Content of Freshly
(see Note 1) of freshly mixed concrete and gives formulas for Mixed Concrete by the Volumetric Method
calculating the yield, cement content, and air content of the C 188 Test Method for Density of Hydraulic Cement
concrete. Yield is defined as the volume of concrete produced C 231 Test Method for Air Content of Freshly Mixed
from a mixture of known quantities of the component materi- Concrete by the Pressure Method
als. 3. Terminology
1.2 The values stated in either SI units or inch-pound units
are to be regarded separately as standard. The values stated in 3.1 Symbols:
each system may not be exact equivalents; therefore, each
system shall be used independently of the other. Combining A = air content (percentage of voids) in the concrete
values from the two systems may result in non-conformance C = actual cement content, lb/yd3 or kg/m3
with the standard. Cb = mass of cement in the batch, lb or kg
NOTE 1—Unit weight was the previous terminology used to describe D = density (unit weight) of concrete, lb/ft3 or kg/m3
the property determined by this test method, which is mass per unit M = total mass of all materials batched, lb or kg (see Note
volume. 3)
Mc = mass of the measure filled with concrete, lb or kg
1.3 The text of this test method references notes and
Mm = mass of the measure, lb or kg
footnotes that provide explanatory information. These notes Ry = relative yield
and footnotes (excluding those in tables) shall not be consid- T = theoretical density of the concrete computed on an
ered as requirements of this test method. airfree basis, lb/ft3 or kg/m3 (see Note 2)
Y = yield, volume of concrete produced per batch, yd3 or
2. Referenced Documents
m3
2.1 ASTM Standards:2 Yd = volume of concrete which the batch was designed to
C 29/C 29M Test Method for Bulk Density (“Unit Weight”) produce, yd3 or m3
and Voids in Aggregate Yf = volume of concrete produced per batch, ft3
C 31/C 31M Practice for Making and Curing Concrete Test V = total absolute volume of the component ingredients
Specimens in the Field in the batch, ft3 or m3
C 143/C 143M Test Method for Slump of Hydraulic- Vm = volume of the measure, ft3 or m3
Cement Concrete
NOTE 2—The theoretical density is, customarily, a laboratory determi-
C 150 Specification for Portland Cement nation, the value for which is assumed to remain constant for all batches
made using identical component ingredients and proportions. It is calcu-
1 lated from the following equation:
This test method is under the jurisdiction of ASTM Committee C09 on
Concrete and Concrete Aggregates and is the direct responsibility of Subcommittee T 5 M/V (1)
C09.60 on Testing Fresh Concrete.
Current edition approved June 1, 2009. Published July 2009. Originally approved The absolute volume of each ingredient in cubic feet is equal to the
in 1938. Last previous edition approved in 2008 as C 138/C 138M – 08. quotient of the mass of that ingredient divided by the product of its
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
specific gravity times 62.4. The absolute volume of each ingredient in
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Standards volume information, refer to the standard’s Document Summary page on cubic metres is equal to the mass of the ingredient in kilograms divided by
the ASTM website. 1000 times its specific gravity. For the aggregate components, the bulk

*A Summary of Changes section appears at the end of this standard.


Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.

1
C 138/C 138M – 09
specific gravity and mass should be based on the saturated, surface-dry NOTE 5—The metal should not be readily subject to attack by cement
condition. For cement, the actual specific gravity should be determined by paste. However, reactive materials such as aluminum alloys may be used
Test Method C 188. A value of 3.15 may be used for cements manufac- in instances where as a consequence of an initial reaction, a surface film
tured to meet the requirements of Specification C 150. is rapidly formed which protects the metal against further corrosion.
NOTE 3—The total mass of all materials batched is the sum of the NOTE 6—The top rim is satisfactorily plane if a 0.01-in. [0.3-mm] feeler
masses of the cement, the fine aggregate in the condition used, the coarse gage cannot be inserted between the rim and a piece of 1⁄4-in. [6-mm] or
aggregate in the condition used, the mixing water added to the batch, and thicker plate glass laid over the top of the measure.
any other solid or liquid materials used.
4.5 Strike-Off Plate—A flat rectangular metal plate at least
4. Apparatus ⁄ in. [6 mm] thick or a glass or acrylic plate at least 1⁄2 in. [12
14

mm] thick with a length and width at least 2 in. [50 mm]
4.1 Balance—A balance or scale accurate to 0.1 lb [45 g] or greater than the diameter of the measure with which it is to be
to within 0.3 % of the test load, whichever is greater, at any used. The edges of the plate shall be straight and smooth within
point within the range of use. The range of use shall be
a tolerance of 1⁄16 in. [2 mm].
considered to extend from the mass of the measure empty to 4.6 Mallet—A mallet (with a rubber or rawhide head)
the mass of the measure plus its contents at 160 lb/ft3 [2600 having a mass of 1.25 6 0.50 lb [600 6 200 g] for use with
kg/m3].
measures of 0.5 ft3 [14 L] or smaller, and a mallet having a
4.2 Tamping Rod—A round, straight steel rod, with a 5⁄8 in.
mass of 2.25 6 0.50 lb [1000 6 200 g] for use with measures
[16 mm] 6 1⁄16 in. [2 mm] diameter. The length of the tamping
larger than 0.5 ft3.
rod shall be at least 4 in. [100 mm] greater than the depth of the 4.7 Scoop—of a size large enough so each amount of
measure in which rodding is being performed, but not greater concrete obtained from the sampling receptacle is representa-
than 24 in. [600 mm] in overall length (See Note 4). The length tive and small enough so it is not spilled during placement in
tolerance for the tamping rod shall be 6 1⁄8 in. [4 mm]. The rod
the measure.
shall have the tamping end or both ends rounded to a
hemispherical tip of the same diameter as the rod. 5. Sample
NOTE 4—A rod length of 16 in. [400 mm] to 24 in. [600 mm] meets the 5.1 Obtain the sample of freshly mixed concrete in accor-
requirements of the following: Practice C 31/C 31M, Test Method C 138/ dance with Practice C 172.
C 138M, Test Method C 143/C 143M, Test Method C 173/C 173M and
Test Method C 231. 6. Procedure
4.3 Internal Vibrator—Internal vibrators may have rigid or 6.1 Base the selection of the method of consolidation on the
flexible shafts, preferably powered by electric motors. The slump, unless the method is stated in the specifications under
frequency of vibration shall be 7000 vibrations per minute or which the work is being performed. The methods of consoli-
greater while in use. The outside diameter or the side dimen- dation are rodding and internal vibration. Rod concretes with a
sion of the vibrating element shall be at least 0.75 in. [19 mm] slump greater than 3 in. [75 mm]. Rod or vibrate concrete with
and not greater than 1.50 in. [38 mm]. The length of the shaft a slump of 1 to 3 in. [25 to 75 mm]. Consolidate concretes with
shall be at least 24 in. [600 mm]. a slump less than 1 in. by vibration.
4.4 Measure—A cylindrical container made of steel or other NOTE 7—Nonplastic concrete, such as is commonly used in the
suitable metal (see Note 5). The minimum capacity of the manufacture of pipe and unit masonry, is not covered by this test method.
measure shall conform to the requirements of Table 1 based on
6.2 Place the concrete in the measure using the scoop
the nominal size of aggregate in the concrete to be tested. All
described in 4.7. Move the scoop around the perimeter of the
measures, except for measuring bowls of air meters which are
measure opening to ensure an even distribution of the concrete
also used for Test Method C 138/C 138M tests, shall conform
with minimal segregation. Fill the measure in the number of
to the requirements of Test Method C 29/C 29M. When mea-
layers required by the consolidation method (6.3 or 6.4).
suring bowls of air meters are used, they shall conform to the
6.3 Rodding—Place the concrete in the measure in three
requirements of Test Method C 231, and shall be calibrated for
layers of approximately equal volume. Rod each layer with 25
volume as described in Test Method C 29/C 29M. The top rim
strokes of the tamping rod when nominal 0.5-ft3 [14-L] or
of the air meter bowls shall be smooth and plane within 0.01 in.
smaller measures are used, 50 strokes when nominal 1-ft3
[0.3 mm] (see Note 6).
[28-L] measures are used, and one stroke per 3 in.2 [20 cm3]
of surface for larger measures. Rod each layer uniformly over
TABLE 1 Capacity of Measures
the cross section with the rounded end of the rod using the
Nominal Maximum Size
of Coarse Aggregate
Capacity of MeasureA required number of strokes. Rod the bottom layer throughout
its depth. In rodding this layer, use care not to damage the
in. mm ft3 L
bottom of the measure. For each upper layer, allow the rod to
1 25.0 0.2 6
1 1⁄ 2 37.5 0.4 11
penetrate through the layer being rodded and into the layer
2 50 0.5 14 below approximately 1 in. [25 mm]. After each layer is rodded,
3 75 1.0 28 tap the sides of the measure 10 to 15 times with the appropriate
4 1⁄ 2 112 2.5 70
6 150 3.5 100
mallet (see 4.6) using such force so as to close any voids left
A
by the tamping rod and to release any large bubbles of air that
The indicated size of measure shall be used to test concrete containing
aggregates of a nominal maximum size equal to or smaller than that listed. The may have been trapped. Add the final layer so as to avoid
actual volume of the measure shall be at least 95 % of the nominal volume listed. overfilling.

2
C 138/C 138M – 09
6.4 Internal Vibration—Fill and vibrate the measure in two Y~m3! 5 M/D (4)
approximately equal layers. Place all of the concrete for each 7.3 Relative Yield—Relative yield is the ratio of the actual
layer in the measure before starting vibration of that layer. volume of concrete obtained to the volume as designed for the
Insert the vibrator at three different points for each layer. In batch (see Note 10) calculated as follows:
compacting the bottom layer, do not allow the vibrator to rest
on or touch the bottom or sides of the measure. In compacting Ry 5 Y/Yd (5)
the final layer, the vibrator shall penetrate into the underlying NOTE 10—A value for Ry greater than 1.00 indicates an excess of
layer approximately 1 in. [25 mm]. Take care that the vibrator concrete being produced whereas a value less than this indicates the batch
is withdrawn in such a manner that no air pockets are left in the to be “short” of its designed volume. In practice, a ratio of yield in cubic
specimen. The duration of vibration required will depend upon feet per cubic yard of design concrete mixture is frequently used, for
example, 27.3 ft3/yd3.
the workability of the concrete and the effectiveness of the
vibrator (see Note 8). Continue vibration only long enough to 7.4 Cement Content—Calculate the actual cement content
achieve proper consolidation of the concrete (see Note 9). as follows:
Observe a constant duration of vibration for the particular kind C 5 Cb /Y (6)
of concrete, vibrator, and measure involved. 7.5 Air Content—Calculate the air content as follows:
NOTE 8—Usually, sufficient vibration has been applied as soon as the A 5 [~T 2 D!/T] 3 100 (7)
surface of the concrete becomes relatively smooth.
NOTE 9—Overvibration may cause segregation and loss of appreciable or
quantities of intentionally entrained air. A 5 [~Yf 2 V!/Yf# 3 100 ~inch2pound units! (8)
6.5 On completion of consolidation the measure must not or
contain a substantial excess or deficiency of concrete. An
A 5 [~Y 2 V!/Y] 3 100 ~SI units! (9)
excess of concrete protruding approximately 1⁄8 in. [3 mm]
above the top of the mold is optimum. A small quantity of 8. Report
concrete may be added to correct a deficiency. If the measure
contains a great excess of concrete at completion of consoli- 8.1 Report the following information:
dation, remove a representative portion of the excess concrete 8.1.1 Identification of concrete represented by the sample.
with a trowel or scoop immediately following completion of 8.1.2 Date of test.
consolidation and before the measure is struck-off. 8.1.3 Volume of density measure to the nearest 0.001 ft3
6.6 Strike-Off—After consolidation, strike-off the top sur- [0.01 L].
face of the concrete and finish it smoothly with the flat 8.1.4 Density (Unit Weight) to the nearest 0.1 lbs/ft3 [1.0
strike-off plate using great care to leave the measure just level kg/m3].
full. The strike-off is best accomplished by pressing the 8.1.5 Yield, when requested, to the nearest 0.1 yd3 [0.1 m3].
strike-off plate on the top surface of the measure to cover about 8.1.6 Relative Yield, when requested, to the nearest 0.01.
two thirds of the surface and withdrawing the plate with a 8.1.7 Cement Content, when requested, to the nearest 1.0 lb
sawing motion to finish only the area originally covered. Then [0.5 kg].
place the plate on the top of the measure to cover the original 8.1.8 Air Content, when requested, to the nearest 0.1 per-
two thirds of the surface and advance it with a vertical pressure cent.
and a sawing motion to cover the whole surface of the measure
9. Precision and Bias
and continue to advance it until it slides completely off the
measure. Several final strokes with the inclined edge of the 9.1 The following estimates of precision for this test method
plate will produce a smooth finished surface. are based on a collection of data from various locations by the
6.7 Cleaning and Weighing—After strike-off, clean all ex- National Ready Mixed Concrete Association.3 The data repre-
cess concrete from the exterior of the measure and determine sent concrete mixtures with slump ranging from 3 to 6 in. [75
the mass of the concrete and measure to an accuracy consistent to 150 mm] and density ranging from 115 to 155 lb/ft3 [1842 to
with the requirements of 4.1. 2483 kg/m3] and included air-entrained and non air-entrained
concrete. The study was conducted using 0.25 ft3 [7-L] and 0.5
7. Calculation ft3 [14-L] measures.
7.1 Density (Unit Weight)—Calculate the net mass of the 9.1.1 Single-Operator Precision—The single operator stan-
concrete in pounds or kilograms by subtracting the mass of the dard deviation of density of freshly mixed concrete has been
measure, Mm, from the mass of the measure filled with found to be 0.65 lb/ft3 [10.4 kg/m3] (1s). Therefore, results of
concrete, Mc. Calculate the density, D, ft3 or yd3,by dividing two properly conducted by the same operator on the same
the net mass of concrete by the volume of the measure, Vm as sample of concrete should not differ by more than 1.85 lb/ft3
follows: [29.6 kg/m3] (d2s).
9.1.2 Multi-Operator Precision—The multi-operator stan-
D 5 ~Mc – Mm!/Vm (2) dard deviation of density of freshly mixed concrete has been
7.2 Yield—Calculate the yield as follows:
Y~yd3! 5 M/~D3 27! (3) 3
Mullings, G. M., NRMCA/NAA Joint Research Lab Study “Series D 324
or Accuracy of Concrete Density Test,” Feb. 17, 2000.

3
C 138/C 138M – 09
found to be 0.82 lb/ft3 [13.1 kg/m3] (1s). Therefore, results of 10. Keywords
two properly conducted tests by the two operators on the same
10.1 air content; cement content; concrete; relative yield;
sample of concrete should not differ by more than 2.31 lb/ft3
unit weight; yield
[37.0 kg/m3] (d2s).
9.2 Bias—This test method has no bias since the density is
defined only in terms of this test method.

SUMMARY OF CHANGES

Committee C09 has identified the location of selected changes to this test method since the last issue,
C 138/C 138M – 08, that may impact the use of this test method. (Approved June 1, 2009)

(1) Revised 4.2 to alter requirements of tamping rod. (3) Revised 6.3 to alter wording of tamping rod use.
(2) Added Note 4 describing acceptable tamping rod length.

Committee C09 has identified the location of selected changes to this test method since the last issue,
C 138/C 138M – 07, that may impact the use of this test method. (Approved March 1, 2008)

(1) Added new 4.7 to define a scoop. (2) Added new 6.2 to describe how to use a scoop.

ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned
in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk
of infringement of such rights, are entirely their own responsibility.

This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and
if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards
and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the
responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should
make your views known to the ASTM Committee on Standards, at the address shown below.

This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,
United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above
address or at 610-832-9585 (phone), 610-832-9555 (fax), or service@astm.org (e-mail); or through the ASTM website
(www.astm.org).