Vous êtes sur la page 1sur 5

VISUAL LEVEL

INDICATORS

LV...
The level indicators series is available for both static and These indicators are available in three configurations, with
mobile applications; the construction materials used make it transparent plastic body, with black body, and/or an aluminum
possible to operate with wide temperature variations and body. Fixing to reservoirs with unthreaded holes or reduced
compatibility with all hydraulic fluids. thickness can be achieved using series LCC/T
Series LV... level indicators are available with fixing center equipped with expansion kit.
distance from 3.0” to 39.3”. Temperature
LVK • LVA: from -13°F to +212°F
This level indicator series is available with electric alarm and • LVU: from -13°F to +158°F
visual and electrical temperature switches, level indicators are • LVU: from -13°F to +212°F (only with pyrex lens)
available with fixing center distance from 3.0” to 10”. • LVK/LC...: from -4°F to +176°F
Compatibility
LC...
LVA/LVK/LVU
LC... series sight plugs allow visibility of the fluid contained in • NBR seals and Cork Gasket, compatible with:
the reservoirs, showing the level and also any changes in Mineral oils to ISO 2943 - aqueous emulsions
transparency and emulsion. Synthetic fluids, glycol water.
• FPM seals, compatible with:
Synthetic fluids type HS-HFDR-HFDS-HFDU.
LC...
• Mineral oils to ISO 2943 - aqueous emulsions
46 Synthetic fluids, glycol water.
2 1 3a
Series LVA
6

3c
Dimensions
3b

Reservoir LVA......S LVA......T


7
holes

0.75”
5

B
4

A
H
A
LVA (Materials)

0.75”
ØC
1 - Cover: Polyamide A/F
2 - Screws: Phosphated steel 1.5” 6 (mm) 0.93” 0.77”

3 - Seals: NBR or
FPM
Weight
4 - Lens: Polyamide Size A H (lbs)
5 - Nameplate: Painted aluminum
LVA10 3” 4.5” 0.29
6 - Terminal cap: Nylon LVA20 5” 6.5” 0.40
7 - Nuts: Galvanized steel LVA30 10” 11.5” 0.51

Type B C
Quantity per pack
Number of Parts
LVA......M10 M10 0.41”
LVA 10 LVA......M12 M12 0.49”
LVA......U38 3/8” UNC 0.41”
LVA......U12 1/2” UNC 0.53”
Screw tightening torque: 11 ft-lbs

Ordering information
LVA20T.....S01
1 2 3 4 5 6

LVA
Example: LVA 20 T A P M10 S01
1 - Size 4 - Cover

10 P Cover polyammide

20 5 - Connection

30 M10 Screws M10

2 - Accessories M12 Screws M12

S Without thermometer U38 Screws 3/8” UNC

T With thermometer U12 Screws 1/2” UNC

3 - Seals 6 - Options
A NBR S01 With nuts - Tag MP Filtri

V FPM S02 Without nuts - Tag MP Filtri

MP Filtri reserves the right to make changes to the information described herein at any time it deems fit
in relation to technical or commercial requirements. Copyright. All rights reserved. 47
Series LVK
Description
Visual/electric level indicator with temperature
controls for both static and mobile applications. 3
Completely transparent, it provides a view of the fluid
1
over the entire length, both from the front and on both
sides. 2
The quality and thickness, 0,16”, of the
4
construction material provides the utmost
3
dependability and mechanical strength without any
need for additional protection.

LVK (Materials)
1 - Body: Polyammide
2 - Screws: Nickel plated brass (Standard)
AISI 316 (Option)
3 - Seals: NBR (Standard) 5 2

FPM (Option) Compatibility


4 - Float: Polyammide • NBR seals, compatible with:
Mineral oils to ISO 2943 - aqueous emulsions
5 - Sensor thermometer: Screw + thermometer
Synthetic fluids, glycol water.
Temperatures: from -4°F to +176°F • FPM seals, compatible with:
Screw tightening torque: 10Nm Synthetic fluids type HS-HFDR-HFDS-HFDU.

Dimensions
Reservoir Sensor thermometer
holes
0.63”

Ø 2.05”
A/F - 6 mm

A/F - 12 mm
A/F - 22 mm
H

M12
A

0.91” 2.44”
B

0.63”

Weight
ØC (lbs)
1.1” 0.63” 1.26” TV12 0.22 Kit Sensor thermometer
+ Screw M12
1.42”

Weight 2.68”
Size A H (lbs)
Type B C
LVK10 3” 4.25” 0.31
LVK20 5” 6.26” 0.37 LVK......M10 M10 0.41”
48 LVK30 10” 11.26” 0.55 LVK......M12 M12 0.49”
Combination of available electrical contacts

Electrical contact with no liquid Electrical contact with no liquid + thermostat

Normally open SPDT Normally open Normally


N.O. Switch N.O. closed N.C.

T T T T

Thermostat

Thermostat
1 2 1 2 1 2 1 2

3 3 3

Level Level

Available thermostated contact N.C. - N.O. in


both setups

Electrical contact with no liquid + PT 100 Dimension screw +


electrical contact + thermostated or PT 100
Normally SPDT
closed N.O. Switch

T T
PT 100

1
PT 100

1 2 2

B
3 3
1.10” 0.87”
Level Level

Thermostat electrical specifications Electrical specifications Contact with no liquid


Voltage: up to 250 V Switchable N.O.
Frequency: 50 Hz / 60 Hz Switch
N.C.
Load values: 4.0 A. cos ϕ 0.6 (IMOT) D.C. Switchable Power 40 W 20 W
6,3 A. cos ϕ 1 (IN) D.C. current intensity - A.C. 40 V.A. -
Max load: 10 A. cos ϕ 1 Switchable voltage 2 A 1 A
Switching temperature: 122°F - 140°F - 158°F Voltage switchable 230 V 150 V
Tolerances: ± 41°F

49
Ordering information

1 2 3 4 5 6 7

LVK
Example: LVK 20 A M12 1 S S P01

1 - Size 5 - Style

10 S Standard

20 T Thermostat Only for


connection
30 P PT 100 “M12”

2 - Seal 6 - Thermostat

A NBR S Standard Without

1 122°F N.O.
3 - Connection
2 140°F N.O.
M10 Screws M10
3 158°F N.O. Only for
M12 Screws M12 (Standard)
5 122°F N.C. style “T”
4 - Electrical contacts with no liquid*
1 N.O. 6 140°F N.C.

2 N.C. 7 158°F N.C.

3 Switch SPDT 7 - Options

P01 MP Standard
* Available electrical contacts see page 49

MP Filtri reserves the right to make changes to the information described herein at any time it deems fit
in relation to technical or commercial requirements. Copyright. All rights reserved.

Accessories/Options*

TV12 Kit w/ Sensor thermometer Screw M12


M10 X Kit w/ Screws M10 stainless steel AISI 316
M12 X Kit w/ Screws M12 stainless steel AISI 316
02050432 Kit w/ FPM seals
* All the accessories are supplied separately from code LVK

50

Vous aimerez peut-être aussi