CEASE FIRE DRY AGENT CF-33

SECTION 1 – NAME & HAZARD SUMMARY


Material Name: CEASE FIRE DRY AGENT CF-33
Manufacturer: Cease Fire LLC. Phone (360) 567-0990

SECTION 2 – INGREDIENTS
Cease Fire® System Units were tested and approved by Underwriters Laboratory & Factory Mutual Research Corp., for “Total
Flooding” & “Local Application” fire protection of Class A, B and C fires. Cease Fire® has a patent pending Dry Agent that is non-
corrosive & non-conductive.
Monoammonium Phosphate (MAP)* Specific formulation of Cease Fire® Dry Agent is PROPRIETARY

SECTION 3 – PHYSICAL DATA


Boiling Point: NA Specific Gravity (H20 = 1): 1.80 Vapor Pressure (mm Hq): N/A
Vapor Density (Air – 1): N/A Solubility In Water: Slightly Water Soluble
Appearance: Yellow Powder Odor: No Appearable Odor Melting Point: 374° Fahrenheit / 190° Celsius

SECTION 4 – FIRE & EXPLOSION HAZARD


Flash Point: Noncombustible Method Used: N/A
Flammable Limits in Air % b Volume: LEL Lower: N/A UEL Upper: N/A
Auto-Ignition Temperature: N/A
Extinguisher Media: N/A, This Material is a Fire Extinguisher Agent Special Fire Fighting Procedures: N/A
Unusual Fire & Explosion Hazards: N/A

SECTION 5 – REACTIVITY DATA


Stability: Stable Conditions to Avoid: N/A
Incompatibility (Materials to Avoid): Do Not Mix With Different Types of Dry Chemical Extinguishing Agents.
Hazardous Polymerization: Will Not Occur

SECTION 6 – HEALTH HAZARD ASSESSMENT


Acute: Transient Cough, Irritation of Airways, & Shortness of Breath Chronic: Pnuemonconiosis
Signs & Symptoms of Exposure: Coughing & Irritation of Airways
Medical Conditions Generally Aggravated by Exposure: Asthma, Bronchitis, or Other Respiratory Illness
Chemical Listed as Carcinogen or Potential Carcinogen: N/A
Emergency & First Aid Procedures: Move victims to fresh air. Wash affected area with soap & water. Flush from eyes with large
amounts of water for at least 15 minutes. Seek medical attention if necessary.
Routes of Entry: Inhalation, Eyes, Skin, Ingestion

SECTION 7 – SPILL OR LEAK PROCEDURES


Precautions to be Taken in Handling & Storage: Cease Fire Dry Agent CF-33 should be stored only in its original suppression unit.
Other Precautions: None
Steps to be Taken in Case Material is Released or Spilled: Sweep up. Store in covered containers. Do not reuse.

SECTION 8 – SPECIAL PROTECTION INFORMATION


Respiratory Protection: Dust respirator approved by NIOSH / MSHA schedule TC-ZIC
Ventilation: N/A Local Exhaust: N/A Mechanical General: N/A Special: N/A Other: N/A
Protective Gloves: Sensitive Individuals Should Wear Gloves
Eye Protection: Safety glasses are recommended Other Protective Clothing or Equipment: N/A
Work / Hygienic Practices: Avoid breathing of dust. Wash off with soap & water.
The information herein is given in good faith but no warrant, expressed or implied, is made.

Issue Date: August, 2003 Revision Date: August, 2016 MSDS CF-33
www.detectofuego.com - info@detectofuego.com - 300.624.03.06
Cease Fire
811 NE 112th Avenue Ste 104
Vancouver, WA 98684
t: 360-567-0990
f: 360-567-1242
THE LEADER IN PRE-ENGINEERED FIRE SUPPRESSION TECHNOLOGY i: www.ceasefire.com

CFP 80 Low Profile


Dry Chemical Fire Suppression System Unit Specifications:

Suppressing Agent: CF-33 ABC Dry Chemical Blend

Maximum Total Flood Volume: 4’x 4’x 5’ = 80 Cu. Ft.


1.22m x 1.22m x 1.52m = 2.67 Cubic Meters

Reach Coverage Area: 4’x 4’ = 16 Sq. Ft.


1.22m x 1.22m = 1.49 Square Meters

Temperature Rating/Validation: - 20°F to 120°F / -29°C to 49°C

Cylinder: Worthington / Small DDI

Diameter: 3.5” / 8.90cm

Height: 10.5” + 3.5” Coupling Assembly / 26.67cm + 8.90cm

Capacity: 1.7 lbs / .77 kg

Unit Weight: 5.15 lbs / 2.34 kg

Ship Weight: 10.2 lbs / 4.64 kg

Operating Pressure: 175 psi / 1207 kPa

Propellant: High Purity Compressed Dry Nitrogen

Standard System Activation: 155° Fahrenheit /


68.3° Celsius

www.detectofuego.com - info@detectofuego.com - 300.624.03.06


Cease Fire
811 NE 112th Avenue Ste 104
Vancouver, WA 98684
t: 360-567-0990
f: 360-567-1242
THE LEADER IN PRE-ENGINEERED FIRE SUPPRESSION TECHNOLOGY i: www.ceasefire.com

CFP 96 Dry Chemical Fire Suppression System Unit


Specifications:

Suppressing Agent: CF-33 ABC Dry Chemical Blend

Maximum Total Flood Volume: 4’x 4’x 6’ = 96 Cu. Ft.


1.22m x 1.22m x 1.83m = 2.72 Cubic Meters

Reach Coverage Area: 4’x 4’ = 16 Sq. Ft.


1.22m x 1.22m = 1.49 Square Meters

Temperature Rating/Validation: - 20°F to 120°F / -29°C to 49°C

Cylinder: Worthington / Small DDI

Diameter: 3.5” / 8.90cm

Height: 10.5” + 3.5” Coupling Assembly / 26.67cm + 8.90cm

Capacity: 1.7 lbs / .77 kg

Unit Weight: 5.15 lbs / 2.34 kg

Ship Weight: 10.2 lbs / 4.64 kg

Operating Pressure: 175 psi / 1207 kPa

Propellant: High Purity Compressed Dry Nitrogen

Standard System Activation: 155° Fahrenheit / 68.3° Celsius

www.detectofuego.com - info@detectofuego.com - 300.624.03.06


Cease Fire
811 NE 112th Avenue Ste 104
Vancouver, WA 98684
t: 360-567-0990
f: 360-567-1242
THE LEADER IN PRE-ENGINEERED FIRE SUPPRESSION TECHNOLOGY i: www.ceasefire.com

CFP 640 Dry Chemical Suppression System Unit Specifications:

Suppressing Agent: CF-33 ABC Dry Chemical Blend

Maximum Total Flood Volume: 8.2’x 8.2’x 10’ = 672.4 Cu. Ft.
2.49m x 2.49m x 3.05m = 18.91 Cubic Meters

Reach Coverage Area: 8.2’x 8.2’ = 67.24 Sq. Ft.


2.49m x 2.49m = 6.20 Square Meters

Temperature Rating/Validation: -20°F to 120°F / -29°C to 49°C

Cylinder: Worthington Cylinder

Diameter: 7.50” / 19.05cm

Height: 11.38” + 3.50” Coupling Assembly / 29cm + 8.90cm

Capacity: 7 lbs / 3.18 kg

Unit Weight: 19.25 lbs / 8.73 kg

Ship Weight: 23.25 lbs / 10.55 kg

Operating Pressure: 175 psi / 1207 kPa

Propellant: High Purity Compressed Dry Nitrogen

Standard System Activation: 155° Fahrenheit / 68.3° Celsius

Designed and Tested by Cease Fire® in Accordance with NFPA-17 and UL-1254

UL listed for Pre-engineered Extinguishing Systems

www.detectofuego.com - info@detectofuego.com - 300.624.03.06


Cease Fire
811 NE 112th Avenue Ste 104
Vancouver, WA 98684
t: 360-567-0990
f: 360-567-1242
THE LEADER IN PRE-ENGINEERED FIRE SUPPRESSION TECHNOLOGY i: www.ceasefire.com

CFP 640 Low Profile


Dry Chemical Suppression System Unit Specifications:

Suppressing Agent: CF-33 ABC Dry Chemical Blend

Maximum Total Flood Volume: 8.2’x 8.2’x 10’ = 672.4 Cu. Ft.
2.49m x 2.49m x 3.05m = 18.91 Cubic Meters

Reach Coverage Area: 8.2’x 8.2’ = 67.42 Sq. Ft.


2.49m x 2.49m = 6.20 Square Meters

Temperature Rating/Validation: -20°F to 120°F / -29°C to 49°C

Cylinder: Worthington Cylinder

Diameter: 7.50” / 19.05cm

Length: 11.38” + 3.12” Coupling Assembly / 29cm + 8.60cm

Capacity: 7 lbs / 3.18 kg

Unit Weight: 25.25 lbs / 11.45 kg

Ship Weight: 29 lbs / 13.15 kg

Operating Pressure: 175 psi / 1207 kPa

Propellant: High Purity Compressed Dry Nitrogen

Standard System Activation: 155° Fahrenheit / 68.3° Celsius

Designed and Tested by Cease Fire® in Accordance with NFPA-17 and UL-1254

UL listed for Pre-engineered Extinguishing Systems

www.detectofuego.com - info@detectofuego.com - 300.624.03.06


Cease Fire
811 NE 112th Avenue Ste 104
Vancouver, WA 98684
t: 360-567-0990
f: 360-567-1242
THE LEADER IN PRE-ENGINEERED FIRE SUPPRESSION TECHNOLOGY i: www.ceasefire.com

CFP 1100 Low Profile


Dry Chemical Fire Suppression System Unit Specifications:

Suppressing Agent: CF-33 ABC Dry Chemical Blend

Maximum Total Flood Volume: 10’x 10’x 13’ = 1300 Cu. Ft.
3.05m x 3.05m x 3.96m = 36.84 Cubic Meters

Reach Coverage Area: 10’x 10’ = 100 Sq. Ft.


3.05m x 3.05m = 9.30 Square Meters

Temperature Rating/Validation: - 20°F to 120°F / -29°C to 49°C

Cylinder: Worthington Cylinder

Diameter: 7.50” / 19.05cm

Length: 30.41” / 77.24cm

Capacity: 15.00 lbs / 6.80 kg

Unit Weight: 48.00 lbs / 21.78 kg

Ship Weight: 55.00 lbs / 24.95 kg

Operating Pressure: 175 psi / 1207 kPa

Propellant: High Purity Compressed Dry Nitrogen

Standard System Activation: 155°Fahrenheit / 68.3° Celsius

www.detectofuego.com - info@detectofuego.com - 300.624.03.06


Cease Fire
811 NE 112th Avenue Ste 104
Vancouver, WA 98684
t: 360-567-0990
f: 360-567-1242
THE LEADER IN PRE-ENGINEERED FIRE SUPPRESSION TECHNOLOGY i: www.ceasefire.com

CFP 1300 Dry Chemical Fire Suppression System Unit


Specifications:

Suppressing Agent: CF-33 ABC Dry Chemical Blend

Maximum Total Flood Volume: 10’x10’x13’ = 1300 Cu. Ft.


3.05m x 3.05m x 3.96m = 36.84 Cubic Meters

Reach Coverage Area: 10’x10’ = 100 Sq. Ft.


3.05m x 3.05m = 9.30 Square Meters

Temperature Rating/Validation: - 20°F to 120°F / -29°C to 49°C

Cylinder: Manchester #11

Diameter: 12.25” / 31cm

Height: 8.38” + 3.5” Coupling Assembly / 21.27cm + 8.90cm

Capacity: 10 lbs / 4.54 kg

Unit Weight: 24 lbs / 10.89 kg

Ship Weight: 32 lbs / 14.52 kg

Operating Pressure: 175 psi / 1207 kPa

Propellant: High Purity Compressed Dry Nitrogen

Standard System Activation: 155° Fahrenheit / 68.3° Celsius

www.detectofuego.com - info@detectofuego.com - 300.624.03.06


Cease Fire
811 NE 112th Avenue Ste 104
Vancouver, WA 98684
t: 360-567-0990
f: 360-567-1242
i: www.ceasefire.com
THE LEADER IN PRE-ENGINEERED FIRE SUPPRESSION TECHNOLOGY

CFP 1700 Dry Chemical Fire Suppression System Unit


Specifications:

Suppressing Agent: CF-33 ABC Dry Chemical Blend

Maximum Total Flood Volume: 11.5’x 11.5’x 13’ = 1719 Cu. Ft.
3.5m x 3.5m x 3.96m = 48.5 Cubic Meters

Reach Coverage Area: 11.50’x 11.50’ = 132.25 Sq. Ft.


3.5m x 3.5m = 12.25 Square Meters

Temperature Rating/Validation: - 20°F to 120°F / -29°C to 49°C

Cylinder: Manchester #11

Diameter: 12.25” / 31cm

Height: 8.38” + 3.5” Coupling Assembly / 21.27cm + 8.90cm

Capacity: 15 lbs / 6.18 kg

Unit Weight: 29 lbs / 13.15 kg

Ship Weight: 37 lbs / 16.78 kg

Operating Pressure: 175 psi / 1207 kPa

Propellant: High Purity Compressed Dry Nitrogen

Standard System Activation: 155° Fahrenheit / 68.3° Celsius

www.detectofuego.com - info@detectofuego.com - 300.624.03.06


Cease Fire
811 NE 112th Avenue Ste 104
Vancouver, WA 98684
t: 360-567-0990
f: 360-567-1242
THE LEADER IN PRE-ENGINEERED FIRE SUPPRESSION TECHNOLOGY i: www.ceasefire.com

CFP 3375 Dry Chemical Fire Suppression System Unit


Specifications:

Suppressing Agent: CF-33 ABC Dry Chemical Blend

Maximum Total Flood Volume: 15’x15’x15’ = 3375 Cu. Ft.


4.57m x 4.57m x 4.57m = 95.44 Cubic Meters

Reach Coverage Area: 15’x15’ = 225 Sq. Ft.


4.57m x 4.57m = 20.88 Square Meters

Temperature Rating/Validation: -20°F to 120°F / -29°C to 49°C

Cylinder: Manchester #30

Diameter: 12.25” / 31cm

Height: 19.56” + 3.50” Coupling Assembly / 50cm + 8.90cm

Capacity: 30.00 lbs / 13.61 kgs

Unit Weight: 61.00 lbs / 27.67 kgs

Ship Weight: 65.00 lbs / 29.48 kgs

Operating Pressure: 175 psi / 1207 kPa

Propellant: High Purity Compressed Dry Nitrogen

Standard System Activation: 155° Fahrenheit / 68.3° Celsius

www.detectofuego.com - info@detectofuego.com - 300.624.03.06


Cease Fire
811 NE 112th Avenue Ste 104
Vancouver, WA 98684
t: 360-567-0990
f: 360-567-1242
THE LEADER IN PRE-ENGINEERED FIRE SUPPRESSION TECHNOLOGY i: www.ceasefire.com

CFP 6750 Dry Chemical Fire Suppression System Unit


Specifications:

Suppressing Agent: CF-33 ABC Dry Chemical Blend

Maximum Total Flood Volume: 15’x15’x30’ = 6750 Cu. Ft.


4.57m x 4.57m x 9.14m = 190.89 Cubic Meters

Reach Coverage Area: 15’x15’ = 225 Sq. Ft.


4.57m x 4.57m = 20.88 Square Meters

Temperature Rating/Validation: -20°F to 120°F / -29°C to 49°C

Cylinder: Manchester #30

Diameter: 12.25” / 31cm

Height: 19.56” + 3.50” Coupling Assembly / 50cm + 8.90cm

Capacity: 50.00 lbs / 22.68 kg

Unit Weight: 81.00 lbs / 36.74 kg

Ship Weight: 85.00 lbs / 38.56 kg

Operating Pressure: 175 psi / 1207 kPa

Propellant: High Purity Compressed Dry Nitrogen

Standard System Activation: 155° Fahrenheit / 68.3° Celsius

www.detectofuego.com - info@detectofuego.com - 300.624.03.06