TF42-5.

7
TF42-5.7 Thermal Overload Relay


General Information
Extended Product Type TF42-5.7
Product ID 1SAZ721201R1038
EAN 4013614398100
Catalog Description TF42-5.7 Thermal Overload Relay
The TF42-5.7 thermal overload relay is an economic electromechanical protection device for the main
circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device
has trip class 10. Further features are the temperature compensation, trip contact (NC), signal contact (NO),
Long Description
automatic- or manual reset selectable, trip-free mechanism, STOP function and a trip indication. The
overload relays are connected directly to the block contactors. Single mounting kits are available as
accessory.


Ordering
Minimum Order Quantity 1 piece
Customs Tariff Number 85364900


Dimensions
Product Net Width 45 mm
Product Net Height 88.3 mm
Product Net Depth / Length 70.5 mm
Product Net Weight 0.13 kg


Popular Downloads
Data Sheet, Technical Information 2CDC106023D0201
Data Sheet, Technical Information (Part 2) 1SAZ700506F0014
Data Sheet, Technical Information (Part 3) 1SAZ70051101
1SAZ700504
Instructions and Manuals 2CDC106022M6802
Instructions and Manuals (Part 2) 2CDC106076M6801
Dimension Diagram 1SAZ700405F0001


Technical
Setting Range 4.2 ... 5.7 A
Rated Operational Voltage Auxiliary Circuit 600 V AC/DC
Main Circuit 690 V AC
TF42-5.7 2
Rated Operational Current (I e ) 5.7 A

Rated Operational Current AC-3 (I e ) 5.7 A

Rated Frequency (f) Auxiliary Circuit 50 Hz


Auxiliary Circuit 60 Hz
Auxiliary Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Rated Impulse Withstand Voltage (U imp ) Auxiliary Circuit 6 kV
Main Circuit 6 kV
Rated Insulation Voltage (U i ) 690 V

Number of Poles 3
Number of Auxiliary Contacts NC 1
Number of Auxiliary Contacts NO 1
Number of Protected Poles 3
Conventional Free-air Thermal Current (I th ) Auxiliary Circuit NC 6 A
Auxiliary Circuit NO 4 A
Rated Operational Current AC-15 (I e ) (120 V) NC 3 A
(120 V) NO 0.75 A
(240 V) NC 3 A
(240 V) NO 0.75 A
(400 V) NC 0.75 A
(400 V) NO 0.75 A
(500 V) NC 0.75 A
(500 V) NO 0.75 A
Rated Operational Current DC-13 (I e ) (125 V) NC 0.55 A
(125 V) NO 0.55 A
(24 V) NC 1.25 A
(24 V) NO 1.25 A
(250 V) NC 0.27 A
(250 V) NO 0.27 A
(500 V) NC 0.15 A
(500 V) NO 0.15 A
(60 V) NC 0.55 A
(60 V) NO 0.55 A
Degree of Protection IP20
Pollution Degree 3
Connecting Capacity Auxiliary Circuit Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible 1/2x 0.75 ... 1 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1/2x 0.75 ... 4 mm²
Connecting Capacity Main Circuit Flexible with Ferrule 1/2x 0.75 ... 4 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 4 mm²
Flexible 1/2x 0.75 ... 4 mm²
Rigid 1/2x 0.75 ... 4 mm²
Tightening Torque Auxiliary Circuit 1 ... 1.5 N·m
Main Circuit 1.5 ... 2.5 N·m
Wire Stripping Length Auxiliary Circuit 9 mm
Main Circuit 12 mm
Recommended Screw Driver Main Circuit Pozidriv 2
Mounting Position Position 1 to 5
Power Loss at Rated Operating Conditions per Pole 1.1 ... 2.0 W
Suitable For AF09
AF12
AF16
AF26
AF30
AF38
Standards IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 60947-5-1
TF42-5.7 3
UL 60947-1
UL 60947-4-1


Environmental
Ambient Air Temperature Operation -25 ... +60 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Ambient Air Temperature Compensation Yes
Maximum Operating Altitude Permissible 2000 m
Resistance to Shock acc. to IEC 60068-2-27 11 ms Pulse 25g
Resistance to Vibrations acc. to IEC 60068-2-6 5g / 3 ... 150 Hz
RoHS Status Following EU Directive 2011/65/EU


Technical UL/CSA
Maximum Operating Voltage UL/CSA Main Circuit 600 V AC
Ampere Rating UL/CSA 5.7 A
Contact Rating UL/CSA (NC:) B600
(NC:) Q600
(NO:) Q600
(NO:) D300
Connecting Capacity Main Circuit UL/CSA Flexible 1/2x 18-10 AWG
Stranded 1/2x 18-10 AWG
Connecting Capacity Auxiliary Circuit UL/CSA Flexible 1/2x 18-12 AWG
Stranded 1/2x 18-12 AWG
Tightening Torque UL/CSA Auxiliary Circuit 9 ... 13 in·lb
Main Circuit 13 ... 22 in·lb


Certificates and Declarations (Document Number)
ABS Certificate 1SAA941001-0102
ATEX Certificate 1SAA941001-3901
BV Certificate 1SAA941001-0202
CB Certificate 1SAA941009-2001
CCC Certificate 1SAA941006-3804
cUL Certificate 1SAA941001-1702
cUR Certificate cUL_E48139
Declaration of Conformity - CE 1SAD938508-0181
DNV GL Certificate 1SAA941001-0302
EAC Certificate 1SAA941002-2701
GL Certificate 1SAA941007-0401
GOST Certificate 1SAA941001-2701
Instructions and Manuals 2CDC106022M6802
LR Certificate 1SAA941001-0502
RINA Certificate 1SAA941000-0802
RMRS Certificate 1SAA941000-0704
RoHS Information 1SAD938508-0181
UL Certificate UL_E48139


Container Information
TF42-5.7 4
Package Level 1 Units 1 piece
Package Level 1 Width 48 mm
Package Level 1 Height 92 mm
Package Level 1 Depth / Length 78 mm
Package Level 1 Gross Weight 0.145 kg
Package Level 1 EAN 4013614398100
Package Level 2 Units 40 piece
Package Level 2 Width 280 mm
Package Level 2 Height 210 mm
Package Level 2 Depth / Length 395 mm
Package Level 2 Gross Weight 7.346 kg
Package Level 2 EAN 4013614440144


Classifications
Object Classification Code F
ETIM 4 EC000106 - Thermal overload relay
ETIM 5 EC000106 - Thermal overload relay
ETIM 6 EC000106 - Thermal overload relay
ETIM 7 EC000106 - Thermal overload relay
eClass 7.0 27371501
UNSPSC 39121521


Categories
Low Voltage Products and Systems  → Control Products  → Contactors  → Thermal Overload Relays