ALTURAS Y VOLÚMENES DE LOS EMBALSES

COTA ALTURA AREA(ACUMULA) equidistancia


m.s.n.m ACUMULADA AREA m2 m VOLUMEN VOLUMEN
m2 m3 m3
3307 0 28.37 28.37
3308 1 128.24 156.61 1 78.31 78.31
3309 2 306.73 463.34 1 217.49 295.79
3310 3 566.69 1030.03 1 436.71 732.50
3311 4 793.99 1824.02 1 680.34 1412.84
3312 5 987.84 2811.85 1 890.91 2303.75
3313 6 1241.93 4053.78 1 1114.88 3418.63
3314 7 1461.71 5515.49 1 1351.82 4770.45
3315 8 1744.96 7260.45 1 1603.34 6373.79
3316 9 2091.40 9351.85 1 1918.18 8291.97
3317 10 2559.90 11911.75 1 2325.65 10617.61
3318 11 3283.52 15195.26 1 2921.71 13539.32
3319 12 4074.22 19269.48 1 3678.87 17218.19
3320 13 4812.02 24081.50 1 4443.12 21661.31
3321 14 5556.07 29637.57 1 5184.05 26845.35

NAME= 3319.0

3319 19269.48 3319 17218.19


3319.0 X 3319.0 X
3320 24081.50 3320 21661.31
AREA=X 19269.48 VOLUMEN=X 17218.19
Area m2

30000 25000 20000 15000 10000 5000 0


3325

3320

3315

3310

3305

3300
0 5000 10000 15000 20000 25000 30000

Volumen Acumulado m3
3300
0 5000 10000 15000 20000 25000 30000

Volumen Acumulado m3

VOLUMEN ACUMULADO m3 area

Chart Title
0
5184.046 78.3055
3340

4443.1185 217.4875

3321
3320
3678.867 3320 436.709
3319 3308
3307 3309
3340

4443.1185 217.4875

3321
3320
3678.867 3320 436.709
3319 3308
3307 3309
3310
3318 3300 3311
2921.7075 3312 680.3365
3317
3313
3316
33153314

2325.6465 890.9115

1918.1785 1114.881

1603.338 1351.82

Column B
CARGA DEL VERTEDERO hd 1.4 m

NOMBRE DESCRIPCION COTA ALTURA


Z. CORONA NIVEL MAXIMO DE OPERACIÓN 3317.60 m.s.n.m
NAME NIVEL MAXIMO EXTRAORDINARIO 3319.00 m.s.n.m
NAMINO NIVEL MINIMO DE OPERACIÓN m.s.n.m
NAMIN NIVEL MINIMO DE EMBALSE m.s.n.m

COTA CORONA 3321.14 msnm


COTA NAME 3320.40 msnm
COTA NAMO 3319.00 msnm
COTA DE DESPLANTE 3307.00 msnm
0

30000
30000
DISEÑO DE PRESA DE TIERRA

2.1 DISEÑO GEOMETRICO

2.1.1 Altura de la presa

bl= hm + hv + hr+ ha + hd

_Altura por marea

V2 F
hm 
62.82 D

D
 vol. hasta la cot a del NAME
Area del espejo en la cot a del NAME

DATOS
Parámetro valor und
D= 4.5 m
V= 18 Km/h
F= 0.0184 Km

hm= 0.02 m

Altura de la ola por viento, m

hv = 3.22 (V F)1/2 – 26.9 (F)1/4 + 76 , en cm.

hv= 0.68 cm

Altura de rodamiento de las olas, producida por el viento(hr), m

4
hr  ( hm  hv )
3
4
hr  ( hm  hv )
3
hr= 0.93 m

Altura por máxima avenida probable(hd), m

hd= 1.4 m

Asentamiento máximo de la corona(ha), m

ha= 0.4 m

BL= 2.03 m

Cota de la corona

〖����〗 _𝒄𝒐𝒓𝒐𝒏𝒂= 〖����〗 _𝒏𝒂𝒎𝒐+𝑩�


Cnamo= 3319.00 m.s.n.m
BL= 2.03 m
NAME= 3319.63 m.s.n.m
C.corona= 3321.03 m.s.n.m

Altura de la presa

〖� =𝑪𝑶𝑻� 〗 _𝒄𝒐𝒓𝒐𝒏𝒂− ALTURA DE CIMIENTO DEL DIQUE


C.corona= 3321.03
A.cimiento= 3307.00

H= 14.03 3.5086521798

2.1.1 Ancho de la corona(B)


H
B 3
5

B= 5.8 m

2.1.1 Taludes
talud aguas arriba talud de aguas abajo
GW, SM 2.1 2.1

2.1.1 Bermas o banquetas

A.berma= 4 m

2.1.1 Protección del paramento

M = 103 Hs3
M = masa
Hs = Altura significativa de la onda, m

Hs = 0.34 F1/2 + 0.76 – 0.26 F1/4

Hs= 0.71 m

M= 358.46 Kg
W= 358.46 Kg

MEDIO Kmáx/Kmin Kmáx


1 20 0.0005
2 10 0.000007
3 25 0.002
4 50 0.03
DISEÑO POR INFILTRACION
Transformaciòn de un medio homogèneo y anisòtropo en un medio homogèneo e isòtropo

Kx, Kmax= 1.00E-07 m/s nos dan en laboratorio


Ky, Kmin= 1.05E-08 m/s
Kx, Kmax
= 9.5
Ky, Kmin

K= 3.24E-08 m/s

Hallando las acotaciones de la secciòn transformada (x)


Todas las medidas a lo largo de (Y) seran las mismas

TRANSFORMADA

k min
x'  x
k max

PIE X1= 27.22 m 0.32 m


NUCLEO X2= 3.51 m 0.65 m
NUCLEO X3= 2.97 m 0.97 m
NUCLEO X4= 4.47 m 1.30 m
CORONA X5= 0.72 m 1.62 m
CORONA X6= 6.72 m 1.95 m
TALÓN X7= 34.72 m 2.27 m
BERMA X8= 35.22 m 2.60 m
BERMA X9= 25.72 m 2.92 m
BERMA X 10 = 21.57 m 3.24 m
BERMA X 11 = 13.40 m 3.57 m
BERMA X 12 = 9.14 m 3.89 m
BERMA X 13 = 16.43 m 4.22 m
BERMA X 14 = 20.43 m 4.54 m
BERMA X 15 = 38.66 m 4.87 m

curva de kozeny T=

y 2  y o2
x  yo  d 2  h2  d
2 yo

Donde:
d= 4.18 delta 7.76 m
h= 11.97 0.3*delta 2.33 m 14.00

Yo= 8.50 a0= 4.25 12.00

x y 10.00
4.18 11.97
8.00
3.5 11.48
3 11.10 6.00
2 10.31
1 9.45 4.00
0 8.50
-1 7.43 2.00

-2 6.18
0.00
-3 4.61 -5 -4 -3 -2 -1 0 1 2 3
-4 2.06
-4.25 0.00
a α C
c  angulo 96.37 30º 0.32
a  a 60º 0.32
70º 0.31
valor de c según casagrande 80º 0.28
90º 0.26
C= 0.247

INTERPOLANDO SE TIENE
a+∆a= 8.48
∆a= 2.10
90 0.26
ANTITRANSFORMADA 96.37 x
100 0.24
k
x  x ' / min

k max c= x 0.247
y
X´ 1 = 4.18 m X1= 12.88 m 11.97
X´ 2 = 3.50 m X2= 10.79 m 11.48
X´ 3 = 3.00 m X3= 9.25 m 11.10
X´ 4 = 2.00 m X4= 6.16 m 10.31
X´ 5 = 1.00 m X5= 3.08 m 9.45
X´ 6 = 0.00 m X6= 0.00 m 8.50
X´ 7 = -1.00 m X7= -3.08 m 7.43
X´ 8 = -2.00 m X8= -6.16 m 6.18
X´ 9 = -3.00 m X9= -9.25 m 4.61
X´ 10 = -4.00 m X 10 = -12.33 m 2.06
X´ 11 = -4.25 m X 11 = -13.10 m 0.00
X´ 12 = 0.96 m X 12 = 2.96 m
X´ 13 = 3.03 m X 13 = 9.34 m
X´ 14 = 0.97 m X 14 = 2.99 m
X´ 15 = 1.66 m X 15 = 5.12 m
X´ 16 = 5.75 m X 16 = 17.72 m
X´ 17 = 4.85 m X 17 = 14.95 m
X´ 18 = 2.93 m X 18 = 9.03 m
X´ 19 = 1.12 m X 19 = 3.45 m
X´ 20 = 37.24 m X 20 = 114.78 m
X´ 21 = 46.03 m X 21 = 141.87 m
X´ 22 = 44.29 m X 22 = 136.51 m
X´ 23 = 30.81 m X 23 = 94.96 m
X´ 24 = 19.07 m X 24 = 58.78 m
X´ 25 = 11.41 m X 25 = 35.17 m
X´ 26 = 5.46 m X 26 = 16.83 m

CALCULO DEL CAUDAL DE FILTRACION

K= 3.244428E-08
a1= 5.56
b1= 4.37
a1/b1= 1.27
1/(a1/b1)= 0.79
(1/(a1/b1))+1/2= 1.29
Nf= 3
Nd= 3
hf= 11.97
q= 5.54831E-07 m3/s/m
q= 1.61E-04 m3/s
CALCULO DEL GRADIENTE HIDRAULICO e=n/(1-n)

CUADRO ∆� b i n e �_� Fs(tub) CONDICION


1 2.99 4.37 0.68 0.45 0.82 2.85 14.86 NO EXISTE TUBIFICACION
2 2.99 4.37 0.68 0.45 0.82 2.85 14.86 NO EXISTE TUBIFICACION
3 2.99 4.37 0.68 0.45 0.82 2.85 14.86 NO EXISTE TUBIFICACION
4 2.99 4.37 0.68 0.45 0.82 2.85 14.86 NO EXISTE TUBIFICACION
5 2.99 4.37 0.68 0.45 0.82 2.85 14.86 NO EXISTE TUBIFICACION
6 2.99 4.37 0.68 0.45 0.82 2.85 14.86 NO EXISTE TUBIFICACION
7 2.99 4.37 0.68 0.45 0.82 2.85 14.86 NO EXISTE TUBIFICACION
8 2.99 4.37 0.68 0.45 0.82 2.85 14.86 NO EXISTE TUBIFICACION
9 2.99 4.37 0.68 0.45 0.82 2.85 14.86 NO EXISTE TUBIFICACION
10 2.99 4.37 0.68 0.45 0.82 2.85 14.86 NO EXISTE TUBIFICACION
11 2.99 4.37 0.68 0.45 0.82 2.85 14.86 NO EXISTE TUBIFICACION
12 2.99 4.37 0.68 0.45 0.82 2.85 14.86 NO EXISTE TUBIFICACION
13 2.99 4.37 0.68 0.45 0.82 2.85 14.86 NO EXISTE TUBIFICACION
14 2.99 4.37 0.68 0.45 0.82 2.85 14.86 NO EXISTE TUBIFICACION
15 2.99 4.37 0.68 0.45 0.82 2.85 14.86 NO EXISTE TUBIFICACION
16 2.99 4.37 0.68 0.45 0.82 2.85 14.86 NO EXISTE TUBIFICACION
17 2.99 4.37 0.68 0.45 0.82 2.85 14.86 NO EXISTE TUBIFICACION
18 2.99 4.37 0.68 0.45 0.82 2.85 14.86 NO EXISTE TUBIFICACION
19 2.99 4.37 0.68 0.45 0.82 2.85 14.86 NO EXISTE TUBIFICACION
20 2.99 4.37 0.68 0.45 0.82 2.85 14.86 NO EXISTE TUBIFICACION
21 2.99 4.37 0.68 0.45 0.82 2.85 14.86 NO EXISTE TUBIFICACION
22 2.99 4.37 0.68 0.45 0.82 2.85 14.86 NO EXISTE TUBIFICACION
23 2.99 4.37 0.68 0.45 0.82 2.85 14.86 NO EXISTE TUBIFICACION

GRADO DE RESISTENCIA A LA TUBICACION


Gran resistencia a la tubicacion
Ip>15%
Ip= 17.16 OK

DISEÑO DEL FILTRO-DREN


FILTRO
Kx,Kmax= 1.00E-04 m/s Kx, Kmax
=20
Ky= 5.00E-06 m/s Ky, Kmin

Kfitro= 2.236068E-05 m/s


Ksuelo= 3.24E-08 m/s

Kfiltro>=20 Ksuelo OK

SIENDO :
SUELO: CL
FILTRO: SM

SUELO FILTRO
d15= 0.01 mm D15= 0.05 mm
d85= 9.00 mm D85= 19.00 mm

NORMAS PARA EL PROYECTO DE FILTROS

A) condicion de la capacidad de retencion

D15  9 d 85

D15= 0.052
ok
9*d85= 81
D15  0.7 mm

D15= 0.052 OK

B)Capacidad de drenaje del filtro

k filtro ≥ 50 a 100 veces k suelo

k filtro = 2.24E-05 m/s


Ksuelo= 3.2444284E-08 m/s

k filtro/k suelo ≥ 50 OK

D 15filtro ≥ 5 d15 suelo

D15= 0.052
ok
5*d15= 0.05

ESTABILIDAD INTERNA DEL FILTRO


D15(G)
IR  5
D85(F)
PUNTO 0.85X% =Y X% (Y+15)% Dx D85(F) D15(G) IR Condicón
1 4.25 5 19.25 0.02 0.01 0.06 4.83 ok
2 12.75 15 27.75 0.05 0.04 0.07 1.95 ok
3 21.25 25 36.25 0.07 0.06 0.13 2.32 ok
4 29.75 35 44.75 0.12 0.08 0.68 8.50 no cumple
5 38.25 45 53.25 0.71 0.17 1.90 11.18 no cumple
6 46.75 55 61.75 2.50 0.98 4.10 4.18 ok
7 55.25 65 70.25 4.75 2.60 8.40 3.23 ok
8 63.75 75 78.75 11.30 4.90 14.00 2.86 ok
9 72.25 85 87.25 19.00 8.20 20.00 2.44 ok
10 80.75 95 95.75 29.00 18.00 29.00 1.61 ok

UUN
100 %

(Y+15)%

X%

Y=0.85X%

0%

DY D(Y+15)

DX

ESPESOR DEL FILTRO


q
CALCULO DEL d1
d1 
k filtro sen
q= 5.5483052E-07 m3/s/m
kx= 2.24E-05
Kx/Ky= 20

Ky= 1.12E-06

k= 2.24E-05

L= 114.85
ᵧ= 90
sen90= 1

d1= 0.0248127752
cosideramos 1m

CALCULO DEL D2 1/ 2
 4 q 
d2  
 k filtro 
d2= 3 m

verificando la capacidad de drenaje del filtro dren

Kx filtro = 1.00E-04 m/s


Kxpresa= 1.00E-07 m/s
Kxciment= 1.00E-06 m/s
D15filtro= 0.05 mm
d15presa= 0.01 mm
d15 cimen= 0.01 mm
D85filtro= 19.00 mm
d85presa= 9.00 mm
d85 cimen= 9.00 mm

𝐾𝑥 𝑓𝑖𝑙𝑡𝑟𝑜≥100 𝐾𝑥𝑝𝑟𝑒𝑠� ok
𝐾𝑥 𝑓𝑖𝑙𝑡𝑟𝑜≥100 𝐾𝑥cimentaciión ok
D15 filtro≥5𝑑15d presa ok
D15 filtro≥5𝑑15d cimentacion ok

verificando la capacidad de retención del filtro dren

D15filtro≤5d85 presa ok
D15filtro≤5d85 cimentacion ok
61.53
20.51
y 2  y o2
x 
2 yo

Donde:

14.00

12.00

10.00

8.00
Column D
6.00

4.00

2.00

0.00
-1 0 1 2 3 4 5
Α c α c
100º 0.24 150º 0.09
110º 0.21 160º 0.06
120º 0.18 170º 0.04
130º 0.16 180º 0
140º 0.13 ----- -----
DISEÑO CONTRA DELIZAMIENTO

Ensayo N
Material γ (tn/cm3)
C (tn/m ) φ (º)
2

Enrocado 0.00 43.00 2.30


Espaldón 2.50 35.00 2.71
FILTRO-Dren 4.50 30.00 2.47
Fundación 0.00 45.00 2.35

DIMENSIONES Y PESOS DE LAS TAJADAS

Medidas de la Figura
ITEM Tajada
AREA(m²) Li (m) β° hi (m) hG (m)
1 2.23 2.52 -14.68 0 0.61
2
CIRCULO DE TALUD

6.23 2.46 -5.5 0


3 9.17 2.44 5.27 0
4 11.22 2.52 19.42 0
5 12.19 2.66 33.71 0
6 11.88 2.94 47.16 0
7 9.81 3.5 58.63 0
8 4.12 5.2 67.81 0
ura Tipo de γparcial
Sumergido γ (tn/m3)Wi (tn/m)W (tn/m)
bi(m) di (m) Material (tn/m3)
2.45 15.05 Espaldón SI 2.71 1.71 6.0433
Wsat
Wsat Material
parcial
(tn/m) (tn/m) Base
3.8133

Vous aimerez peut-être aussi