BUILDING MATERIALS APPROVALS
Approved for anchorings in:
▪ Concrete C20/25 to C50/60,
cracked and non-cracked
▪ Hollow blocks made from lightweight
Rescue ladders concrete
▪ Hollow blocks made from concrete
▪ Vertically perforated brick
▪ Perforated sand-lime brick
▪ Solid sand-lime brick
▪ Aerated concrete
▪ Solid brick
▪ Rebar connections
▪ Remedial wall tie VBS 8
▪ Weather facing reconstruction
system FWS II
ADVANTAGES ▪ Stand-off installation Thermax
▪ The FISV injection mortar has numerous system approvals, such as in cracked and non-cracked concrete, masonry and for rebar connections. FISV is thus the universal injection
mortar family with guaranteed reliability for practically all areas of application.
▪ FISVW HIGH SPEED has a significantly shorter curing time than FISV, thus also ensuring swift work progress even at low temperatures.
▪ FISVS LOW SPEED with extended gelling time prevents premature curing of the mortar at higher temperatures and is ideally suited to large drill hole depths.
▪ The extensive range of accessories is ideally suited to the FISV injection mortar family, increases the great flexibility of the system and thus allows for a broad range
of applications.

INSTALLATION
4x 4x

4x 4x

4x 4x

PRE-POSITIONED PUSH-THROUGH PRE-POSITIONED PUSH-THROUGH PRE-POSITIONED PUSH-THROUGH PRE-POSITIONED PUSH-THROUGH

INSTALLATION DETAILS-REBAR
4x 4x 4x

do ≧ 18 mm with oil free compressed air (P > 6 bar)

CURING TIME
Cartridge temperature (mortar) Gelling time Temperature at anchoring base Curing time

‒ 5°C – ± 0°C 24 hrs.


± 0°C – + 5°C 3 hrs.
+ 5°C – +10°C 9 min. + 5°C – +10°C 90 min.
+ 10°C – + 20°C 5 min. + 10°C – + 20°C 60 min.
+ 20°C – + 30°C 4 min. + 20°C – + 30°C 45 min.
+ 30°C – + 40°C 2 min. + 30°C – + 40°C 35 min.
The above times apply from the moment of contact between resin and hardener in the static mixer.
For installation, the cartridge temperature must be at least +5 °C. For longer installation times, i.e. when interruptions occur in work, the mixer should be replaced.

TECHNICAL DATA
Approval Languages on the cartridge Contents Sales unit
[pcs]
Item Art.-No. DIBt ETA
FIS V 360 S 094405 ▯ ■ GB, I, P, E, PRC, JP 1 cartridge 360 ml, 2 x static mixer FIS S 6
FIS S 520742 — — — 10 static mixer 10
FIS V 360 S in bucket 503025 ▯ ■ GB, I, P, E, PRC, JP 20 cartridges 360 ml, 20 x static mixer FIS S 1

DRILL HOLE DIAMETER


FIS V with threaded rods
Anchor type
Threaded rod dia [-] M8 M 10 M 12 M 16 M 20 M 24 M 27 M 30
Drill hole diameter d0 [mm] 10 12 14 18 24 28 28 35

FIS V with rebar


Anchor type
Threaded rod dia [-] T8 T 10 T 12 T 14 T 16 T 20 T 25 T 28
Drill hole diameter d0 [mm] 10/12 12/14 14/16 18 20 25 30 35

35
Injection mortar FIS V

LOADS
fischer Injection mortar FIS V with rebars
Design and Recommended resistance of single anchor with large spacing and large edge distance.
Design resistance
Rod Diameter Φ8 Φ10 Φ12 Φ14

hef [mm] 60 80 120 160 60 100 150 200 60 120 180 240 70 140 210 280
Non-cracked concrete
temperature range (-40°C / +80°C)
Tension static C 20/25 NRd [kN] 11.1 14.7 18.2 18.2 13.8 23.0 28.4 28.4 15.6 33.2 41.0 41.0 19.7 41.0 55.7 55.7
C 50/60 NRd [kN] 13.9 18.2 18.2 18.2 17.4 28.4 28.4 28.4 20.9 41.0 41.0 41.0 25.9 51.7 55.7 55.7
Shear static ≧C 25/25 8.4 8.4 8.4 8.4 13.1 13.1 13.1 13.1 18.8 18.8 18.8 18.8 25.7 25.7 25.7 25.7
Cracked concrete
temperature range (-40°C / +80°C)
Tension static C 20/25 NRd [kN] -- -- -- -- 3.8 6.3 9.4 12.6 7.5 15.1 22.6 30.2 10.3 20.5 30.8 41.0
C 50/60 NRd [kN] -- -- -- -- 4.7 7.9 11.9 15.8 9.5 19.0 28.5 38.0 12.9 25.9 38.8 51.7
Shear static ≧C 25/25 -- -- -- -- 7.5 12.6 13.1 13.1 15.1 18.8 18.8 18.8 20.5 25.7 25.7 25.7

Rod Diameter Φ16 Φ20 Φ24 Φ28

hef [mm] 80 160 240 320 100 200 300 400 125 250 375 500 140 280 420 560
Non-cracked concrete
temperature range (-40°C / +80°C)
Tension static C 20/25 NRd [kN] 24.1 53.6 72.8 72.8 33.7 79.6 113.8 113.8 47.1 117.8 176.7 177.8 55.8 139.5 209.3 223.0
C 50/60 NRd [kN] 33.8 67.5 72.8 72.8 50.1 100.3 113.8 113.8 72.9 148.4 177.8 177.8 86.4 175.8 223.0 223.0
Shear static ≧C 25/25 33.5 33.5 33.5 33.5 52.4 52.4 52.4 52.4 81.8 81.8 81.8 81.8 102.6 102.6 102.6 102.6
Cracked concrete
temperature range (+40°C / +24°C)
Tension static C 20/25 NRd [kN] 13.4 26.8 40.2 53.6 18.8 37.7 56.5 75.4 26.2 52.4 78.5 104.7 32.8 65.7 98.5 131.3
C 50/60 NRd [kN] 16.9 33.8 50.7 67.5 23.7 47.5 71.2 95.0 33.0 66.0 98.9 131.9 41.4 82.7 124.1 165.5
Shear static ≧C 25/25 26.8 33.5 33.5 33.5 37.7 52.4 52.4 52.4 52.4 81.8 81.8 81.8 65.7 102.6 102.6 102.6

Reccommended resistance

Rod Diameter Φ8 Φ10 Φ12 Φ14

hef [mm] 60 80 120 160 60 100 150 200 60 120 180 240 70 140 210 280
Non-cracked concrete
temperature range (-40°C / +80°C)
Tension static C 20/25 NRd [kN] 7.9 10.5 13.0 13.0 9.9 16.5 20.3 20.3 11.2 23.7 29.3 29.3 14.1 29.3 39.8 39.8
C 50/60 NRd [kN] 10.0 13.0 13.0 13.0 12.4 20.3 20.3 20.3 14.9 29.3 29.3 29.3 18.5 36.9 39.8 39.8
Shear static ≧C 25/25 6.0 6.0 6.0 6.0 9.3 9.3 9.3 9.3 13.5 13.5 13.5 13.5 18.3 18.3 18.3 18.3
Cracked concrete
temperature range (-40°C / +80°C)
Tension static C 20/25 NRd [kN] -- -- -- -- 2.7 4.5 6.7 9.0 5.4 10.8 16.2 21.5 7.3 14.7 22.0 29.3
C 50/60 NRd [kN] -- -- -- -- 3.4 5.7 8.5 11.3 6.8 13.6 20.4 27.1 9.2 18.5 27.7 36.9
Shear static ≧C 25/25 -- -- -- -- 5.4 9.0 9.3 9.3 10.8 13.5 13.5 13.5 14.7 18.3 18.3 18.3

Rod Diameter Φ16 Φ20 Φ24 Φ28

hef [mm] 80 160 240 320 100 200 300 400 125 250 375 500 140 280 420 560
Non-cracked concrete
temperature range (-40°C / +80°C)
Tension static C 20/25 NRd [kN] 17.2 38.3 52.0 52.0 24.0 56.8 81.3 81.3 33.6 84.1 126.2 127.0 39.8 99.7 149.5 159.3
C 50/60 NRd [kN] 24.1 48.2 52.0 52.0 35.8 71.6 81.3 81.3 52.1 106.0 127.0 127.0 61.7 125.6 159.3 159.3
Shear static ≧C 25/25 23.9 23.9 23.9 23.9 37.4 37.4 37.4 37.4 58.4 58.4 58.4 58.4 73.3 73.3 73.3 73.3
Cracked concrete
temperature range (+40°C / +24°C)
Tension static C 20/25 NRd [kN] 9.6 19.1 28.7 38.3 13.5 26.9 40.4 53.8 18.7 37.4 56.1 74.8 23.5 46.9 70.4 93.8
C 50/60 NRd [kN] 12.1 24.1 36.2 48.2 17.0 33.9 50.9 67.8 23.6 47.1 70.7 94.2 29.6 59.1 88.7 118.2
Shear static ≧C 25/25 19.1 23.9 23.9 23.9 26.9 37.4 37.4 37.4 37.4 58.4 58.4 58.4 46.9 73.3 73.3 73.3
1)
The loads apply to Reinforcement sheet with yield strength = 460 Mpa
2)
Material safety factor M and load safety factor L=1.4 is included

36
Injection mortar FIS V

LOADS
fischer Injection mortar FIS V with threaded rods

Chemical fixings
Design and Recommended resistance of single anchor with large spacing and large edge distance.
Design resistance 1)
Rod Diameter M6 M8 M10 M12 M16
54 80 90 110 150
hef [mm] 5.8 8.8 A4-70 C-70 5.8 8.8 A4-70 C-70 5.8 8.8 A4-70 C-70 5.8 8.8 A4-70 C-70 5.8 8.8 A4-70 C-70
Non-cracked concrete
temperature range (-40°C / +80°C)
Tension static C 20/25 NRd [kN] 6.1 6.1 6.1 6.1 12.2 14.7 14.7 14.7 19.3 20.7 20.7 20.7 28.1 30.4 30.4 30.4 50.3 50.3 50.3 50.3
C 50/60 NRd [kN] 6.7 7.7 7.7 7.7 12.2 18.6 17.1 17.1 19.3 26.1 26.1 26.1 28.1 38.3 38.3 38.3 52.3 63.3 63.3 63.3
Shear static ≧C 25/25 4.0 6.4 4.5 5.6 7.3 11.7 8.2 10.2 11.6 18.6 13.0 16.2 16.9 27.0 18.9 23.6 31.4 50.2 35.2 44.0
Cracked concrete
temperature range (-40°C / +80°C)
Tension static C 20/25 NRd [kN] -- -- -- -- -- -- -- -- 11.3 11.3 11.3 11.3 16.6 16.6 16.6 16.6 30.2 30.2 30.2 30.2
C 50/60 NRd [kN] -- -- -- -- -- -- -- -- 14.2 14.2 14.2 14.2 20.9 20.9 20.9 20.9 38.0 38.0 38.0 38.0
Shear static ≧C 25/25 -- -- -- -- -- -- -- -- 11.6 18.6 13.0 16.2 16.9 27.0 18.9 23.6 31.4 50.2 35.2 44.0

Rod Diameter M20 M24 M27 M30


180 220 240 300
hef [mm] 5.8 8.8 A4-70 C-70 5.8 8.8 A4-70 C-70 5.8 8.8 A4-70 C-70 5.8 8.8 A4-70 C-70
Non-cracked concrete
temperature range (-40°C / +80°C)
Tension static C 20/25 NRd [kN] 71.6 71.6 71.6 71.6 99.5 99.5 99.5 99.5 115.3 115.3 115.3 115.3 160.2 160.2 160.2 160.2
C 50/60 NRd [kN] 81.7 90.2 90.2 90.2 117.7 125.4 125.4 125.4 145.3 145.3 145.3 145.3 187.0 201.8 201.8 201.8
Shear static ≧C 25/25 49.0 78.4 55.0 68.6 70.6 113.0 79.2 98.8 91.8 146.9 103.0 128.5 112.2 179.5 125.9 157.1
Cracked concrete
temperature range (+40°C / +24°C)
Tension static C 20/25 NRd [kN] 41.5 41.5 41.5 41.5 49.8 49.8 49.8 49.8 54.3 54.3 54.3 54.3 75.4 75.4 75.4 75.4
C 50/60 NRd [kN] 52.2 52.2 52.2 52.2 62.7 62.7 62.7 62.7 68.4 68.4 68.4 68.4 95.0 95.0 95.0 95.0
Shear static ≧C 25/25 49.0 78.4 55.0 68.6 70.6 99.5 79.2 98.8 91.8 108.6 103.0 108.6 112.2 150.8 125.9 150.8

Recomended resistance 1)
Rod Diameter M6 M8 M10 M12 M16
54 80 90 110 150
hef [mm] 5.8 8.8 A4-70 C-70 5.8 8.8 A4-70 C-70 5.8 8.8 A4-70 C-70 5.8 8.8 A4-70 C-70 5.8 8.8 A4-70 C-70
Non-cracked concrete
temperature range (-40°C / +80°C)
Tension static C 20/25 NRd [kN] 4.4 4.4 4.4 4.4 8.7 10.5 10.5 10.5 13.8 14.8 14.8 14.8 20.1 21.7 21.7 21.7 35.9 35.9 35.9 35.9
C 50/60 NRd [kN] 4.8 5.5 5.5 5.5 8.7 13.3 12.2 12.2 13.8 18.7 18.7 18.7 20.1 27.4 27.4 27.4 37.4 45.2 45.2 45.2
Shear static ≧C 25/25 2.9 4.6 3.2 4.0 5.2 8.4 5.9 7.3 8.3 13.3 9.3 11.6 12.0 19.3 13.5 16.9 22.4 35.9 25.2 31.4
Cracked concrete
temperature range (-40°C / +80°C)
Tension static C 20/25 NRd [kN] -- -- -- -- -- -- -- -- 8.1 8.1 8.1 8.1 11.8 11.8 11.8 11.8 21.5 21.5 21.5 21.5
C 50/60 NRd [kN] -- -- -- -- -- -- -- -- 10.2 10.2 10.2 10.2 14.9 14.9 14.9 14.9 27.1 27.1 27.1 27.1
Shear static ≧C 25/25 -- -- -- -- -- -- -- -- 8.3 13.3 9.3 11.6 12.0 19.3 13.5 16.9 22.4 35.9 25.2 31.4

Rod Diameter M20 M24 M27 M30


180 220 240 300
hef [mm] 5.8 8.8 A4-70 C-70 5.8 8.8 A4-70 C-70 5.8 8.8 A4-70 C-70 5.8 8.8 A4-70 C-70
Non-cracked concrete
temperature range (-40°C / +80°C)
Tension static C 20/25 NRd [kN] 51.2 51.2 51.2 51.2 71.1 71.1 71.1 71.1 82.4 82.4 82.4 82.4 114.4 114.4 114.4 114.4
C 50/60 NRd [kN] 58.3 64.5 64.5 64.5 84.0 89.6 89.6 89.6 103.8 103.8 103.8 103.8 133.6 144.2 144.2 144.2
Shear static ≧C 25/25 35.0 56.0 39.3 49.0 50.4 80.7 56.6 70.6 65.6 104.9 73.6 91.8 80.1 128.2 89.9 112.2
Cracked concrete
temperature range (+40°C / +24°C)
Tension static C 20/25 NRd [kN] 29.6 29.6 29.6 29.6 35.5 35.5 35.5 35.5 38.8 38.8 38.8 38.8 53.8 53.8 53.8 53.8
C 50/60 NRd [kN] 37.3 37.3 37.3 37.3 44.8 44.8 44.8 44.8 48.8 48.8 48.8 48.8 67.8 67.8 67.8 67.8
Shear static ≧C 25/25 35.0 56.0 39.3 49.0 50.4 71.1 56.6 70.6 65.6 77.5 73.6 77.5 80.1 107.7 89.9 107.7
1)
The loads apply to fischer threaded rods and careful drill hole cleaning, carried out with a brush and blow-out tool and temperature in the substrate in
the area of the mortar with short term temperature T ≤ + 80 °C and long term temperature T ≤ + 50 °C
2)
Material safety factor M and load safety factor L=1.4 is included

37
Threaded Rod FTR

Threaded rod with hexagonal installation drive in zinc-plated


and hot-dipped galvanised steel.

FTR, zinc-plated steel

Collision protection SW

FTR, hot-dipped galvanised steel


do d1 Tinst

ho = hef t fix
TECHNICAL DATA
l
Thread Nominal Total Min. Max. Min. drill depth Width Installation Related Qty.
drill-Ø length anchorage fixing at prior insertion across torque glas capsule per
d1 depth thickness mode flat box
M do l hef tfix ho SW Tinst
Type Art.-No. [mm] [mm] [mm] ≥ [mm] ≤ [mm] [mm] [mm] [Nm] [pcs.]
Zinc-plated steel
FTR M8 x 110 45809 8 10 110 80 16 80 13 10 50270 RM 8 10
FTR M10 x 130 45810 10 12 130 90 22 90 17 20 50271 RM 10 10
FTR M10 x 165 52248 10 12 165 90 57 90 17 20 50271 RM 10 10
FTR M12 x 160 45812 12 14 160 110 30 110 19 40 50272 RM 12 10
FTR M12 x 220 52255 12 14 220 110 90 110 19 40 50272 RM 12 10
FTR M16 x 190 45813 16 18 190 125 38 125 24 60 50273 RM 16 10
FTR M16 x 250 52256 16 18 250 125 98 125 24 60 50273 RM 16 10
FTR M20 x 260 45814 20 25 260 170 70 170 30 120 50274 RM 20 10
FTR M22 x 255 52257 22 28 255 170 40 170 30 135 79842 RM 24 E 5
FTR M24 x 300 45815 24 28 300 210 65 210 36 150 50275 RM 24 5
FTR M24 x 350 502750 24 28 350 210 115 210 36 150 50275 RM 24 5
FTR M30 x 380 45816 30 35 380 280 70 280 46 300 50276 RM 30 5
Hot-dipped glavanised
FTR M 8 x 110 hdg 502914 8 10 110 80 16 80 13 10 50270 RM 8 10
FTR M 10 x 130 hdg 502915 10 12 130 90 22 90 17 20 50271 RM 10 10
FTR M 12 x 160 hdg 502916 12 14 160 110 30 110 19 40 50272 RM 12 10
FTR M 16 x 190 hdg 502917 16 18 190 125 38 125 24 60 50273 RM 16 10
FTR M 20 x 260 hdg 502918 20 25 260 170 70 170 30 120 50274 RM 20 10
FTR M 24 x 300 hdg 502919 24 28 300 210 65 210 36 150 50275 RM 24 5
*Accessories

50
Threaded Rod FIS A/RGM I

The variable fixing system for concrete/masonry


APPROVALS

(XURSHDQ7HFKQLFDODSSURYDO
2SWLRQIRUFUDFNHGFRQFUHWH
Chemical

ESR-1990

Bridge railings

ADVANTAGES BUILDING MATERIALS VERSION


Due to the high bond strength in connection with the injection Approved for: Zinc-plated steel
mortar FIS EM, the system achieves a very high load level in Concrete C20/25toC50/60 Stainless steel
cracked and non cracked concrete, resulting in a safe application. Cracked and non-cracked
Variable anchorage depths from 4x to 20x the threaded rod Seismic conditions
diameter allow for ideal adaptation to the load to be applied, Also suitable for:
and ensure an optimised installation time and use of materials. Concrete C12/15
The low anchorage depth allows for use in thin base materials. Natural stone with dense structure
The wide range of approved steel types allows for use in all
corrosion resistance classes and offers maximum application
safety.

TECHNICAL DATA

Threaded rod FIS A

Zinc-plated, Zinc-plated, Stainless Drill hole Min. anchorage Usable length Fill quantity Max. anchorage Usable length Fill quantity Sales
steel grade steel grade steel diameter depth with FIS SB depth with FIS SB unit
5.8 8.8 A4-70 hef,min at hef, min hef,max at hef, max
do hef,min tfix,hef min hef,max tfix,hef max
Item Art-No. Art-No. Art-No. (mm) (mm) (mm) (scal units) (mm) (mm) (scal units) (units)
FIS A M 8 x 90 090274 519390 090440 10 60 619 2 78 1 3 10
FIS A M 8 x 110 090275 519391 090441 10 60 39 2 98 1 3 10
FIS A M 8 x 130 090276 519392 090442 10 60 59 2 118 1 4 10
FIS A M 8 x 175 090277 519393 090443 10 60 104 2 160 4 5 10
FIS A M 8 x 1000 509214 509222 509230 10 60 -- 2 160 -- 5 10
FIS A M 10 x 110 090278 – 090444 12 60 37 3 96 1 4 10
FIS A M 10 x 130 090279 – 090447 12 60 57 3 116 1 5 10
FIS A M 10 x 150 090281 517935 090448 12 60 77 3 136 1 5 10
FIS A M 10 x 170 044969 519395 044973 12 60 97 3 156 1 6 10
FIS A M 10 x 190 – 517936 519420 12 60 117 3 176 1 7 10
FIS A M 10 x 200 090282 519396 090449 12 60 127 3 186 1 7 10
FIS A M 10 x 1000* 509215 509223 509231 12 60 -- 3 200 -- 7 10
FIS A M 12 x 120 044971 519397 044974 14 70 34 3 103 1 5 10
FIS A M 12 x 140 090283 519398 090450 14 70 54 3 123 1 6 10
FIS A M 12 x 160 090284 517937 090451 14 70 74 3 143 1 7 10
FIS A M 12 x 180 090285 519399 090452 14 70 94 3 163 1 7 10
FIS A M 12 x 200 – 517938 519421 14 70 114 3 183 1 8 10
FIS A M 12 x 210 090286 – 090453 14 70 124 3 193 1 9 10
FIS A M 12 x 260 090287 – 090454 14 70 174 3 240 4 10 10
FIS A M 12 x 1000* 509216 509224 509232 14 70 -- 3 240 -- 10 10
FIS A M 16 x 130 044972 519400 044975 18 80 30 5 109 1 7 10
FIS A M 16 x 175 090288 519401 090455 18 80 75 5 154 1 10 10
FIS A M 16 x 200 090289 517939 090456 18 80 100 5 179 1 11 10
FIS A M 16 x 250 090290 517940 090457 18 80 150 5 229 1 14 10
FIS A M 16 x 300 090291 519402 090458 18 80 200 5 279 1 17 10
FIS A M 16 x 1000* 509217 509225 509233 18 80 -- 5 320 -- 19 10
FIS A M 20 x 245 090292 519404 090459 24 90 131 11 220 1 28 10
FIS A M 20 x 290 090293 519406 090460 24 90 176 11 265 1 32 10
FIS A M 20 x 1000* – 519410 519427 24 90 -- 11 400 -- 48 10
FIS A M 24 x 290 090294 – 090468 28 96 165 15 260 1 39 5
FIS A M 24 x 380 090295 – 090462 28 96 255 15 350 1 52 5
FIS A M 30 x 340 090296 – 090463 35 120 185 28 304 1 67 5
FIS A M 30 x 430 090297 – 090464 35 120 275 28 394 1 88 5
* excluding nuts and washers – FIS A highly corrosion-resistant steel 1.4529 on request. Additional sizes on request.

52
Threaded Rod FIS A/RGM I

Threaded rod FIS A 1m

Zinc-plated, Zinc-plated, Stainless Drill hole diameter Max. useful length Sales
steel grade steel grade steel FIS EM FIS EM unit
5.8 8.8
do tfix,max
Item Art-No. Art-No. Art-No. (mm) (mm) (pcs)
gvz gvz A4

Chemical
FIS A M 8 x 1000 509214 ¹⁾ 509222 ¹⁾ 509230 ¹⁾ 12 60 10
FIS A M 10 x 1000 509215 ¹⁾ 509223 ¹⁾ 509231 ¹⁾ 14 60 10
FIS A M 12 x 1000 509216 ¹⁾ 509224 ¹⁾ 509232 ¹⁾ 14 70 10
FIS A M 16 x 1000 509217 ¹⁾ 509225 ¹⁾ 509233 ¹⁾ 18 80 10
(1) Order washer and nut separately.

Hexagonal nut and washer

Zinc-plated, Stainless Width across nut Washer (outer diameter x Fits Sales
steel grade steel thickness) unit
5.8
 SW
Art-No. Art-No. (mm) (mm) (mm) (pcs)
Item gvz A4
Nut & washer M8 510509 510513 13 16 x 1.6 FIS A M 8 x 1000 50
Nut & washer M10 510510 510514 17 20 x 2 FIS A M 10 x 1000 50
Nut & washer M12 510511 510515 19 24 x 2.5 FIS A M 12 x 1000 25
Nut & washer M16 510512 510516 24 30 x 3 FIS A M 16 x 1000 20
Nut & washer M20 519737 519738 30 37 x 3 FIS A M 20 x 1000 10

Internal threaded anchor RG MI

Zinc-plated, Stainless Connection Nominal Anchorage RSB Fill quantity Min. bolt Max. bolt Sales
steel grade steel thread drill diameter depth FIS SB penetration penetration unit
5.8 A4-70 M
do hef
Item Art-No. Art-No. (mm) (mm) (scale units) (mm) (mm) (pcs)
RG 12 x 90 M8 I 050552 050565 M8 14 90 RSB 10 5 8 18 10
RG 16 x 90 M10 I 050553 050566 M10 18 90 RSB 12 7 10 23 10
RG 16 x 125 M12 I 050562 050567 M12 20 125 RSB 16 11 12 26 10
RG 22 x 160 M16 I 050563 050568 M16 24 160 RSB 16 E 17 16 35 5
RG 28 x 200 M20 I 050564 050569 M20 32 200 RSB 20 E/24 48 20 45 5

53

Vous aimerez peut-être aussi