I
t is no exaggeration to say that in a
Observtions exposed to enviromnent in terms of wear and
solar power plant, one mounts all their tear are maintained to be of HDG material
investments on a steel structure which (i) Standard Codes: Research on
with 70 micron coating thickness, while the
supports the energy generating solar panels corrosion of steel and its prevention, has
rest of the components can be pre-galvanized
for three decades. The role of mounting been an ongoing execrise for many years
or other newer material.
structures is two fold, one is to optimize now and the codes and guides used to design
structrues and fabricate them have been Limitations: Hot dip galvanization being
the costs involved and make a solar power
developed by our academicians based on a semi-automated process with lot of manual
plant economically viable and the other is to
this thorough research. First step towards intervention, calls for quality manaegemnt at
ensure the durability of a solar power plant.
prevention of corrosion is to employ these every level. In this semi automated process
In this context we dedicate this article to
codes with precision through stringent quality one must be aware that there cannot be
explore the mutliple aspects of corrossion in
norms. machine made perfection in the coating
the mounting structures perspective.
thickness, leading to uneven surfaces. Hot
(ii) Indian Codes and New Materials:
dip galvanization is possible only at higher
Corrosion the Process: Many newer variations of steel which are
thicknesses, and can prove to be pricey, if it
equally or even more capable of resisting
Corrsion, in simple terms is degradation has to be used for complete strcuture.
corrosion need to be explored to optimize for
of ferrous material due to environmental (iv) Pre-galvanized Steel: Pre
economic viability. Codes and Standards for
condidtions. In this process, metal loses its galvanized steel has been in use for many
these newer material may or may not exist
strength and does not serve its design life and years now in developed countries for solar
and have to be verified with testing centers.
capability leading to material failure. mounting. It comes in three main varieties
We at Nuevosol as a part of our continuous
Corrosion is a process of metal research to optimize have conducted several namely 250 GSM, 375 GSM and 550 GSM.
degradation, where the metal when it comes tests at reputed laboratories like TUV to Pre gavlanized steel has been used in many
in contact with an electrolyte, a localised ensure the same. These results have been industries, mainly the automobile industry and
battery is formed and the metal being anodic shared in this article as a case study. pre-engineered buildings as it is known for
loses it electrons and thus its properties. its formability. The features of availability at
(iii) Post-galvanization: Theory and
The electrolyte can be rain water that is lower thicknesses and formability have made
practice suggests that, a 70 micron and above
acidic, high humidity and saline air i.e. air it a favourite for design of solar structures.
coating thickness is required for 20 year or
having high amount of dissolved or suspended Caution has to be exercised in the design
above corrosion proofing for components
minerals like Calcium, Magnesium, etc. and manufacturing using pre galavnized
which are highly exposed to corrossive
steel as the galavnization coating thickness
environments. This is achieved via hot-dip
is a maximum of 20 micron each side for
Protecting the Mounting galavnization (HDG) of processed material.
550 GSM steel. However the usage of these
Structures- Theoritical However in mounting structures base posts/
steels in solar structures is restrictired to
and Practical foundation memebers which are the most
components which are not very exposed to
Sample Result.
Column Post 550 GSM with Zn No sign of corrosion even after 2000
Spray hours of exposure.
Column Post HDG 80 MS No sign of corrosion even after 2000
hours of exposure
Column Post 550 GSM No Sign of corrosion after 2000 hours
of exposure.
Column Post 350 GSM Sign of corrosion after 960 hours of
exposure.
Zinc Alum Coated Steel No sign of corrosion even after 2400
hours of exposure.