Vous êtes sur la page 1sur 14

SITE CANDIDATE INFORMATION PACKAGE

SARF #: 54GA321 Candidate #: 1


SARF Name: EXAMPLE Candidate Name: Sample Properties
Site Acq. Name: John Doe Site Acq. Phone #: (404) 555-1234
Site Acq Email: jdoe@ignitewireless.com Date SCIP Submitted: 3/22/2017

LANDLORD INFORMATION
Landlord Name: Sample Properties LLC Phone #: (123) 456-7890
Street Address: 123 Peachtree Street Email: jsmith@samplepropertiesllc.com
City/State/Zip: Atlanta, GA 30303 Likelihood of Lease: 50%

SITE INFORMATION
Site Address: 1600 Pennsylvania Ave NW City/State/Zip: COLUMBUS, GA 31903
Parcel #: 098 765 432 County: Muscogee
Latitude: 32.458702 Longitude: -84.974177
Structure Type: Self-Support Lease Area: 100’ X 100’
Structure Height: 180’ AMSL: 247.7’
Site Specific Large open industrial lot which looks to be used for semi-truck and trailer
Comments: parking. Property owner also owns the surrounding adjacent lots.

POWER & TELCO


Power Company: Georgia Power Co. Telco Company: BELL SOUTH
Power Contact #: 1-888-660-5890 Telco Contact #: 706-780-2355
Distance to Power: 112’ Distance to Telco: 112’

ACCESS & UTILITIES


Access Easement Required? Yes Access from Public Road? Yes
Existing Access Road? Yes Improvements Needed? Yes
Site Accessibility 24/7? No Separate Utility Easement Required? No
Proposed lease area is towards the rear of the parcel, so new
access easement will need to be from Oakview Ave, and not from
Additional Comments: main entrance. There is a chain link fence that surrounds the
entire property. Power and telco are available directly across the
street from the proposed access.

Page 1 of 14
ZONING INFORMATION
Light Manufacturing/Industrial
Jurisdiction: City of Columbus, GA Zoning District:
(LMI)
Light Manufacturing/Industrial
Contact Name: Kevin Herrit Parcel Zoned:
(LMI)
Contact #: (706) 225-3934 Permit Type: Special Exception
Contact Email: kherrit@columbusga.org Est. Approval Time: 60-90 days
If monopole, tower height from residential structures, all others: 300ft. 1/3 of
Setback(s):
tower height from ROW. LMI: Front 25ft, Side 8ft, Rear 15ft.
Height Restrictions: 200ft for LMI
File by the application deadline (10th of every month). Planning advisory will
have a meeting and determine if they are for or against the project. The public
Zoning Process:
hearing will be held on the first Wednesday of the following month. The
decision will be made following the hearing.
Variance(s) Required? No
The Board of Zoning Appeals shall not grant a variance from the additional
standards applicable to permitted or special exception uses established in
Variance Process:
Article 2 of this Chapter (Which includes the Wireless Telecommunication
Section).
Landscape Buffer Req: Towers and related equipment shall be surrounded by a minimum 10-foot-
wide area meeting buffer standards
Zoning/BP run parallel? No. Zoning must be completed prior to building permit.
BP Turnaround Time: 1-3 weeks.
Notes: All towers over 100 feet in height shall have structural capacity and ground or
interior space to accommodate multiple users.

Page 2 of 14
DIRECTIONS TO SITE

Head north on Capitol Ave SW toward M.L.K. Jr Dr SW 207ft. Use the left lane to turn left onto M.L.K.
Jr Dr SW 436ft. Turn left onto Washington St SW 0.5mi. Continue onto Pulliam St SW 0.3mi. Use the
left 2 lanes to take the ramp onto I-75 S/I-85 S 0.3mi. Merge onto I-75 S/I-85 S 3.1mi. Keep right at the
fork to continue on I-85 S, follow signs for Domestic Airport/Montgomery 5.9mi. Keep left to stay on I-
85 S 49.6mi. Take exit 21 for I-185 S toward Columbus 2.9mi. Continue onto I-185 S 42.0mi. Take exit 6
for GA-22 Spur/Macon Rd 0.1mi. Turn right onto GA-22 Spur W/Macon Rd 0.2mi. Continue straight to
stay on Macon Rd 0.9mi. Continue onto Wynnton Rd 0.4mi. Continue straight to stay on Wynnton Rd
0.6mi. Slight left to stay on Wynnton Rd 0.4mi. Turn left onto Adair Ave 0.2mi. Turn left onto Martin
Luther King Jr Blvd 0.4mi. Turn right onto Shepherd Dr 348ft. Continue onto Oakview Ave 272ft.
Property will be on the right just after the railroad tracks, and across the street from Hunter Electric
Motor & Supply.

Page 3 of 14
STREET MAP SARF MAP

Page 4 of 14
TAX MAP ZONING MAP

Page 5 of 14
FLOODPLAIN TOPOGRAPHY

Page 6 of 14
SITE PHOTO SITE PHOTO
EAST TO SITE NORTH TO SITE

Page 7 of 14
SITE PHOTO SITE PHOTO
WEST TO SITE SOUTH TO SITE

Page 8 of 14
SITE PHOTO SITE PHOTO
EAST FROM SITE NORTH FROM SITE

Page 9 of 14
SITE PHOTO SITE PHOTO
WEST FROM SITE SOUTH FROM SITE

Page 10 of 14
SITE PHOTO SITE PHOTO
TELCO POWER

Page 11 of 14
SITE PHOTO SITE PHOTO
EGRESS INGRESS

Page 12 of 14
SITE SKETCH

Page 13 of 14
PROPERTY DATA

Page 14 of 14

Vous aimerez peut-être aussi