SERVICE INFORMATION
TECHNICAL DATA
Port Sizes: Integrated Fittings for 3/8", 5/16" and 8mm
tubing.
Working Pressure: 20 PSI minimum
150 PSI maximum
50 PSI min., for 3-position valves
Flow: Cv = 1.3
Temperature Range: Solenoid Valve: +5°F to 122°F
Air Pilot: +5°F to 140°F
Media: Air (either lubricated or non-lubricated)
Materials: Valve Body: polyacetal
Diaphragms: Buna N
Combination Manual Override: Locking & non-locking
(single solenoid); non-locking (double solenoid)
RECOMMENDED TUBING
Standard: 3/8" O.D. x .062" wall - poly tubing
5/16" O.D. x .040" wall - nylon tubing
8mm x 1.00mm wall - poly tubing
Adapters available: 1/4" O.D. x .040 wall - poly tubing
Tube nuts are supplied with each valve to accommodate 3/8" x
.062" wall poly tubing as standard. (To obtain tube nuts for
5/16" x .040" wall tubing, order kit part no. P -068156-00000.)
(See page 6 for valves available from factory with 5/16" tube
nuts.)
RECOMMENDED WIRE SIZE
Solenoid Connector - AWG #14 GA maximum.
See Catalog SC-300 for connector options.
ELECTRICAL DATA:
Standard Voltages Power Consumption
(all coils are rated for
continuous duty) Inrush Holding
SM-300.20
OPERATION WARNINGS - INSTALLATION AND MOUNTING
The air pilot signal is controlled in solenoid operators by The user of these devices must conform to all applicable
energizing the solenoid coil to open and close a 3-way valve in electrical, mechanical, piping and other codes in the
the operator. When electrical power is not present, the valve installation, operation or repair of these devices.
may be operated by pushing the manual override button INSTALLATION! Do not attempt to install, operate or
located on the side of the operator. Although the solenoid coil repair these devices without proper training in the
may be energized for extended periods of time, it is better technique of working on pneumatic systems and devices,
practice to design your electrical circuits so the coil is unless under trained supervision.
de-energized for the extended period, and energized for the Compressed air systems contain high levels of stored
shorter period. energy. Do not attempt to connect, disconnect or repair
CAUTION these products when a system is under pressure. Always
exhaust the pressure from an air system before performing
3-Position Closed Center Valves. Simultaneous activation any service work. Failure to do so can result in serious
of both solenoids will provide full supply pressure to both
personal injury.
delivery and exhaust ports. High back-pressure generated in the
delivery lines by heavy loads or high speed may cause leakage Disconnect the electrical power supply before connecting
of the valve. or servicing a solenoid operated valve.
MOUNTING! Devices should be mounted and positioned
3-Position Exhaust Open Center Valves. Simultaneous in such a manner that they cannot be accidently operated.
activation of both solenoids will provide full supply pressure to
both delivery ports and blocked exhaust ports. MAINTENANCE
ADJUSTMENTS TYPE 740 valves may be serviced by shutting off and venting
Adjusting screws for the built in flow controls are located by the main air supply, but removal of the valve from its mounting
the delivery ports. These screws control individual exhaust is recommended. Main air supply must be vented before
restrictors for ports R & S. Control screws are captive and will removing the valves from a manifold.
not back out of the body segment. If a solenoid operated valve fails to operate, pushing the
manual override button on the side of the operator should
GENERAL MAINTENANCE & REPAIR quickly indicate whether the trouble is electrical or mechanical.
RECOMMENDATIONS If required, the solenoid coil can be easily replaced by removing
Maintenance periods should be scheduled in accordance to the retaining nut and slipping off the coil.
frequency of use and working environment of the valves. After disassembly of the valve, clean all metal parts with a
All valves must be visually inspected for wear and given an “in nonflammable solvent and wash all rubber and plastic parts
system” operating performance and leakage test at least once with mild soap and water. Rinse thoroughly and blow dry with
a year. If these visual observations indicate valve repair is a low-pressure air jet. When applicable, check the internal pilot
required, the valve must be removed, repaired and tested. ports in the valve body to make sure the passages are open.
It is recommended that after every two years of service, the Replace any rubber parts that are damaged or worn. Repair
valve is torn down and overhauled regardless of frequency of parts and kits for valve portions and operator portions are
use. available as shown on page 4.
1 BODY 1 17 WASHER 4
2 RESTRICTOR, EXHAUST 2 18 O-RING 2
3 SCREW, RESTRICTOR ADJUSTOR 2 19 O-RING 1
4 SEAT, VALVE 1 20 O-RING 1
5 RING 2 21 DIAPHRAGM 1
6 RING 2 22 DIAPHRAGM 1
7 COVER 1 23 PLUG 1
8 COVER 1 24 PACKING 3
9 PIN 2 25 ARMATURE 2*
(1 if 3 position closed center valve; 26 PLATE, RETAINER 2*
top pin replaced by spring.) 27 SCREW 4*
10 WASHER 2 28 ADAPTER, AIR PILOT 2†
11 STEM 1 29 O-RING 2†
12 INSERT 1 30 SCREW 4†
13 SCREW 8 31 KIT, TUBE NUT 1†
(double solenoid/Air pilot; 32 SOLENOID RETAINER CAP 2*
6-single solenoid/Air pilot) 33 COIL 2*
14 NUT, SELF-LOCKING HEX 4 34 O-RING 2*
15 PIN 1 35 WASHER, MANUAL OVERRIDE 1
16 STEM, BRASS 2 -used only on single solenoid override
* REF. NOs. 25, 26, 27, 32 & 33 are used only on solenoid valves.
† REF. NOs. 28, 29, 30 & 31 are used only on air pilot valves.
Operator part quantities listed are for two operators.
NOTE: REF. NOs. 9, 10, 11, 12, 18, 20 & 24 are not used on single operator type manual override.
2
TYPE 740 VALVE TM
EXPLODED VIEW
3
TYPE 740 VALVE TM
* Includes: Mid-body portion (ref. 1), adj. screws (ref. 3), and
* exhaust restrictor (ref. 2).
COMPLETE SOLENOIDS +
PART NUMBER DESCRIPTION
P -067783-00000 120V/50-60 Hz
P -067784-00000 240V/50-60 Hz MANIFOLD REPAIR
P -067786-00000 12VDC PART NUMBER DESCRIPTION
P -067787-00000 24VDC
P -067782-00000 Valve Latch and Spring
P -068648-00000 24V/50-60 Hz
P -067816-00000 Valve Manifold O-ring Kit
+ Solenoids include: coil, armature (with plunger and spring), armature (to attach valve to manifold)
retainer plate, screws and exhaust strainer nut and o-ring (Ref. Nos. 25, 26, H -897070-01004 Manifold segment, O-ring
27, 32, 33 & 34). (requires 3)
SOLENOID COILS SOLENOID COILS WITH INSERT FOR CSA AND U.L.
PART NUMBER DESCRIPTION LISTED VALVES ONLY
P -048835-00001 120V/50-60 Hz
P -048835-00002 240V/50-60 Hz PART NUMBER DESCRIPTION
P -048835-00004 12VDC P -069713-00001 120V/50-60 Hz
P -048835-00005 24VDC P -069713-00002 240V/50-60 Hz
P -048835-00006 24V/50-60 Hz P -069713-00004 12VDC
P -069713-00005 24VDC
P -069713-00006 24V/50-60 Hz
4
TYPE 740 VALVE
TM
IDENTITY SCHEDULE
All solenoid valves on this page are supplied
without connector(s).
All valves on this page come with 3/8" tube nuts designed
to accomodate 3/8" x .062 wall poly tubing.
5
TYPE 740 VALVE TM
6
TYPE 740 VALVE
TM
*Indicator lights are not available for Dual U.L. listed/CSA Valves.
7
TYPE 740 VALVE
TM