Cathodic Protection Rectifiers, for indoor/outdoor use, stationary, wall or pole mounted:
· “ADVANTAGE” Series Model ADAS; followed by “A” for input rated 115 V, 60 Hz, or “B” for input
rated 208 V, 60 Hz, or “C” for input rated 230 V, 60 Hz, or “D” for input rated 416 V, 60 Hz, or “E” for
input rated 460 V, 60 Hz, or “F” for input rated 115/230 V or 120/240 V, 60 Hz, or “G” for input rated
230/460 V, 60 Hz, or “H” for input rated 600 V, 60 Hz, or “K” for input rated 120 V, 60 Hz, or “O” for input
rated 220 V, 60 Hz, or “P” for input rated 240 V, 60 Hz, or “T” for input rated 480 V, 60 Hz, or “W” for
input rated 240/480 V, 60 Hz, or “Z” for input rating other than listed and up to 600 V, 60 Hz; followed
by “S” for single phase supply voltage, or “T” for three phase supply voltage; direct current output rated
100 V max, 100 A max, suitable for use in maximum 45°C ambient.
https://www.csagroup.org/testing-certification/product-listing/certificate/?cert=22042... 11/26/2018
Certification Record - CSA Group Page 2 of 3
· “BENCHMARK” Series Model BMAS; followed by “A” for input rated 115 V, 60 Hz, or “B” for input
rated 208 V, 60 Hz, or “C” for input rated 230 V, 60 Hz, or “D” for input rated 416 V, 60 Hz, or “E” for
input rated 460 V, 60 Hz, or “F” for input rated 115/230 V or 120/240 V, 60 Hz, or “G” for input rated
230/460 V, 60 Hz, or “H” for input rated 600 V, 60 Hz, or “K” for input rated 120 V, 60 Hz, or “O” for input
rated 220 V, 60 Hz, or “P” for input rated 240 V, 60 Hz, or “T” for input rated 480 V, 60 Hz, or “W” for
input rated 240/480 V, 60 Hz, or “Z” for input rating other than listed and up to 600 V, 60 Hz; followed
by “S” for single phase supply voltage; direct current output rated 100 V max, 34 A max, suitable for use
(https://www.csagroup.org/contact/)
in maximum 45°C ambient.
Note: The Series designations are followed by additional numbers and letters and numbers denoting
Contact an Expert
specific output ratings and options (if any) to derive the Model designation. Refer to the Certification
Report for details.
/kf
https://www.csagroup.org/testing-certification/product-listing/certificate/?cert=22042... 11/26/2018
Certification Record - CSA Group Page 3 of 3
Standards Research
(/standards/standards-
research/)
(https://www.csagroup.org/contact/)
listing/)
Contact an Expert
© 2018 CSA Group Legal (https://www.csagroup.org/legal/)
(https://www.csagroup.org) Privacy Policy (https://www.csagroup.org/legal/privacy-policy/)
Evidence of Insurance (https://www.csagroup.org/legal/evidence-of-insurance/)
HSE Policy (https://www.csagroup.org/hse-policy/)
Accreditation (https://www.csagroup.org/accreditation/)
Accessibility (https://www.csagroup.org/accessibility/)
Annual Report (https://www.csagroup.org/annual-report/)
https://www.csagroup.org/testing-certification/product-listing/certificate/?cert=22042... 11/26/2018