Académique Documents
Professionnel Documents
Culture Documents
ICEpower125ASX2
Page 1 of 31
Version 1.3
ICEpower 125ASX2
2x125W or 1x500W ICEpower Amplifier
with Integrated Power Supply
Contents
General Description .............................................................................................................................................................. 3
Block Diagram ........................................................................................................................................................................ 4
Connection Diagram............................................................................................................................................................. 5
Absolute Maximum Ratings .............................................................................................................................................. 7
Power Specifications............................................................................................................................................................ 9
General Audio Specifications (SE-mode) ...................................................................................................................... 9
General Audio Specifications (BTL-mode) ................................................................................................................. 10
Electrical Specifications ................................................................................................................................................... 12
Timing Specifications ......................................................................................................................................................... 12
Disturbances on the Mains............................................................................................................................................... 12
Mechanical Specifications ................................................................................................................................................ 12
Typical Performance Characteristics........................................................................................................................... 13
Power vs. Frequency .......................................................................................................................................................... 18
Output Impedance ............................................................................................................................................................. 18
Loading ................................................................................................................................................................................... 18
Dissipated Power vs. Output Power ............................................................................................................................. 19
Features ................................................................................................................................................................................. 21
Protection Features ............................................................................................................................................................ 23
Power Supply Protection .................................................................................................................................................. 23
Amplifier Local Protection ............................................................................................................................................... 24
Amplifier Global Protection ............................................................................................................................................. 24
Input/Output Interface .................................................................................................................................................... 24
BTL module setup .............................................................................................................................................................. 25
Output stage ......................................................................................................................................................................... 25
DATASHEET
ICEpower125ASX2
Page 2 of 31
Version 1.3
General Description
The ICEpower125ASX2 is a fully integrated, intelligent audio power conversion solution
designed particularly for highly competitive consumer and professional audio products.
The ICEpower125ASX2 is EMC and safety approved and the “black-box” completeness
allows for fast design-in and minimized time to market. Key benefits include:
The ICEpower125ASX2 is protected against short circuits, overload and overheating and
includes on-board fuses and EMI filtering to provide a CE and FCC pre-approved design.
• 450W @ 1% THD+N, 20Hz – 20kHz, 4Ω, BTL • Fully integrated audio power solution
• 2 x 120W @ 1% THD+N, 20Hz – 20kHz, 4Ω, SE • Rugged construction
(both channels driven) • Thermal protection
• 220W (2Ω) + 58W (8Ω) @ 1% THD+N, 20Hz – • Over current protection
20kHz, SE (both channels driven with asymmetric • Sound optimized soft clipping
load) • Suitable for CE approved designs
• 121dBA dynamic range (BTL-mode) • EMI conforms to: EN55013
• 117dBA dynamic range (SE-mode) EN55020
• THD+N = 0.002% @ 1W (8Ω,1kHz, SE-mode) EN61000-3-2
• THD+N = 0.002% @ 1W (8Ω,1kHz, BTL-mode) EN61000-3-3
• 86,4 % total efficiency @ 250W, 8Ω FCC part 15-B
• CCIF Intermodulation distortion = 0.0009%, 10W, • Safety conforms to: IEC 60065 7th ed.
4Ω, 18.5kHz/1kHz UL 60065 7th ed.
• ±24V unregulated auxiliary power supply
• Selectable Mains 85-132VAC & 170-264VAC
DATASHEET
ICEpower125ASX2
Page 4 of 31
Version 1.3
Release Notes
PCB Version Data Sheet Version Date Revised by Description
Block Diagram
Connection Diagram
The connector interface of the ICEpower125ASX2 module has four industry standard connectors selected for long term relia-
bility.
DATASHEET
ICEpower125ASX2
Page 6 of 31
Version 1.3
1) The ICEpower125ASX2 will operate at lower levels but the output power will be reduced. If the off-line voltage is too low the ICE-
power125ASX2 will switch off.
Auxiliary Supply
2) If the auxillary supply on ICEpower125ASX2 is used with a capacitive load, please remember to read the section “Capacitive Loading of the
AUX Supply” in the ICEpower125ASX2 designer’s manual.
DATASHEET
ICEpower125ASX2
Page 8 of 31
Version 1.3
Input Section
Output Section
Symbol Parameter Value Units
Rload Minimum symmetric load (SE-mode) 3 Ω
Minimum asymmetric load (SE-mode) * 2&6 Ω
Minimum load (BTL-mode) 3 Ω
Iout3) Maximum current draw from amplifier out- 30 A
put
CL Maximal purely capacitive load (SE) 390 nF
Maximal purely capacitive load (BTL) 220 nF
Table 10: Absolute maximum ratings, output section.
*) The amplifier can be loaded asymmetrically. One channel can be loaded with minimum 2Ω. The other channel must then be minimum 6Ω
3) The overcurrent protection will act to protect the amplifier. (See ”Protection features”)
Thermal Section
Symbol Parameter Value Unit
Ta Max. operating ambient temperature 50 OC
Power Specifications
Unless otherwise specified. Ta=25 OC, f=1kHz, RL=4Ω, 230V mains
*) The amplifier can be loaded asymmetrically. One channel can be loaded with minimum 2Ω. The other channel must then be minimum 6Ω
6) An Audio Precision AES17 20 kHz 7th order measurement filter is used for measurements. The frequency 6.67 kHz corresponds to the
worst-case scenario where both 2nd and 3rd harmonics are within the audio band.
6) An Audio Precision AES17 20 kHz 7th order measurement filter is used for measurements. The frequency 6.67 kHz corresponds to the worst-case scenario
where both 2nd and 3rd harmonics are within the audio band.
DATASHEET
ICEpower125ASX2
Page 12 of 31
Version 1.3
Electrical Specifications
Unless otherwise specified, Ta=25 OC.
Symbol Parameter Conditions Min Typ Max Unit
fo Switching frequency channel 1 Idle 490 540 590 kHz
fo Switching frequency channel 2 Idle 450 500 550 kHz
fo Switching frequency BTL Idle 490 540 590 kHz
fs Switching frequency range (amplifier) Idle to full scale 90 - 590 kHz
fsmps Switching frequency (power supply) - 100 - kHz
Timing Specifications
Symbol Parameter Conditions Min Typ Max Unit
tacd Power supply start-up delay. Time from reaching ACmin to all power supplies - 600 1000 ms
(nominal mains) are good and amplifier is active.
Table 16: Timing specifications.
Special care and component selection has made the ICEpower125ASX2 able to withstand surges up to 8kV to avoid damage
to the ICEpower125ASX2 in case of surges caused by lightning.
Mechanical Specifications
The ICEpower125ASX2 has passed tough mechanical tests during development to ensure high reliability.
+80
+28
+70
+26
+60
+24
+50
+22
+40
+20 +30
+20
+18
d +10
+16
B d
g +0 e
+14 g
A -10
+12
-20
+10 -30
-40
+8
-50
+6
-60
+4
-70
+2
-80
-0 -90
20 50 100 200 500 1k 2k 5k 10k 20k 50k 100k
Hz
Figure 3: Frequency response in 4Ω (blue), 8Ω (green) and open load (red). Top – amplitude. Bottom – phase.
+14
-20
+12 -30
+10 -40
+8 -50
+6 -60
+4 -70
+2 -80
-0 -90
20 50 100 200 500 1k 2k 5k 10k 20k 50k 100k
Hz
Figure 4: Frequency response in 4Ω (blue), 8Ω (green) and open load (red). Top – amplitude. Bottom – phase.
DATASHEET
ICEpower125ASX2
Page 14 of 31
Version 1.3
5 5
2 2
1 1
0.5 0.5
0.2 0.2
% 0.1 % 0.1
0.05 0.05
0.02 0.02
0.01 0.01
0.005 0.005
0.002 0.002
0.001 0.001
100m 200m 500m 1 2 5 10 20 50 100 200 100m 200m 500m 1 2 5 10 20 50 100 200
W W
THD+N vs. Po at 100Hz, 1kHz and 6.67kHz 8) (8Ω). 230Vac/50Hz THD+N vs. Po at 100Hz, 1kHz and 6.67kHz 8) (4Ω), 230Vac/50Hz
10 10
5 5
2 2
1 1
0.5 0.5
0.2 0.2
% 0.1 % 0.1
0.05 0.05
0.02 0.02
0.01 0.01
0.005 0.005
0.002 0.002
0.001 0.001
100m 200m 500m 1 2 5 10 20 50 100 200 100m 200m 500m 1 2 5 10 20 50 100 200
W W
THD+N vs. Po at 100Hz, 1kHz and 6.67kHz 8) (8Ω), 115Vac/50Hz THD+N vs. Po at 100Hz, 1kHz and 6.67kHz 8) (4Ω), 115Vac/50Hz
+0 +0
-10 -10
-20 -20
-30 -30
-40 -40
-50 -50
-60 -60
-70 -70
d d
B -80 B -80
r r
-90 -90
A A
-100 -100
-110 -110
-120 -120
-130 -130
-140 -140
-150 -150
-160 -160
-170 -170
0 2k 4k 6k 8k 10k 12k 14k 16k 18k 20k 22k 0 2k 4k 6k 8k 10k 12k 14k 16k 18k 20k 22k
Hz Hz
5 5
2 2
1 1
0.5 0.5
0.2 0.2
0.1 0.1
0.05 0.05
% %
0.02 0.02
0.01 0.01
0.005 0.005
0.002 0.002
0.001 0.001
0.0005 0.0005
0.0002 0.0002
0.0001 0.0001
100m 200m 500m 1 2 5 10 20 50 100 200 600 100m 200m 500m 1 2 5 10 20 50 100 200 600
W W
THD+N vs. Po at 100Hz, 1kHz and 6.67kHz 8) (8Ω). 230Vac/50Hz THD+N vs. Po at 100Hz, 1kHz and 6.67kHz 8) (4Ω), 230Vac/50Hz
10 10
5 5
2 2
1 1
0.5 0.5
0.2 0.2
0.1 0.1
0.05 0.05
% %
0.02 0.02
0.01 0.01
0.005 0.005
0.002 0.002
0.001 0.001
0.0005 0.0005
0.0002 0.0002
0.0001 0.0001
100m 200m 500m 1 2 5 10 20 50 100 200 600 100m 200m 500m 1 2 5 10 20 50 100 200 600
W W
THD+N vs. Po at 100Hz, 1kHz and 6.67kHz 8) (8Ω), 115Vac/50Hz THD+N vs. Po at 100Hz, 1kHz and 6.67kHz 8) (4Ω), 115Vac/50Hz
+0 +0
-10 -10
-20 -20
-30 -30
-40 -40
-50 -50
-60 -60
d -70 d -70
B B
r -80 r -80
A -90 A -90
-100 -100
-110 -110
-120 -120
-130 -130
-140 -140
-150 -150
-160 -160
0 2k 4k 6k 8k 10k 12k 14k 16k 18k 20k 22k 0 2k 4k 6k 8k 10k 12k 14k 16k 18k 20k 22k
Hz Hz
8) An Audio Precision AES17 20 kHz 7th order measurement filter is used for measurements. The frequency 6.67 kHz corresponds to
the worst-case scenario where both 2nd and 3rd harmonics are within the audio band.
DATASHEET
ICEpower125ASX2
Page 16 of 31
Version 1.3
10 +0
5 -10
-20
2
-30
1 -40
0.5 -50
-60
0.2 d -70
B
% 0.1 r -80
0.05 A -90
-100
0.02 -110
0.01 -120
-130
0.005
-140
0.002 -150
0.001 -160
100m 200m 500m 1 2 5 10 20 50 100 200 0 2k 4k 6k 8k 10k 12k 14k 16k 18k 20k 22k
W Hz
CCIF IMD vs. PO, RL = 4Ω, f1 =18,5kHz, f2 = 1kHz, CCIF IMD analysis. RL = 4Ω, PO =10W.
IMD@10W = 0.002%.
10 +0
5 -10
-20
2 -30
1 -40
0.5 -50
-60
0.2 d -70
B
% 0.1 r -80
A -90
0.05
-100
0.02 -110
0.01 -120
-130
0.005
-140
0.002 -150
0.001 -160
100m 200m 500m 1 2 5 10 20 50 100 200 400 0 2k 4k 6k 8k 10k 12k 14k 16k 18k 20k 22k
W Hz
TIM vs. output power. RL = 4Ω, TIM FFT analysis. RL = 4Ω, PO =10W.
TIM@10W = 0.004%
1 +0
0.5 -10
-20
0.2
-30
0.1 -40
0.05
-50
-60
0.02 d -70
B
% 0.01 r -80
A -90
0.005
-100
0.002 -110
0.001 -120
-130
0.0005
-140
0.0002 -150
0.0001 -160
100m 200m 500m 1 2 5 10 20 50 100 200 0 2k 4k 6k 8k 10k 12k 14k 16k 18k 20k 22k
W Hz
CCIF IMD vs. PO, RL = 4Ω, f1 =18.5kHz, f2 = 1kHz, CCIF IMD analysis. RL = 4Ω, PO =10W.
IMD@10W = 0.0003%.
1 +0
-10
0.5
-20
-30
0.2
-40
-50
0.1
-60
0.05 d -70
B
% r -80
0.02 A -90
-100
0.01
-110
-120
0.005
-130
-140
0.002
-150
0.001 -160
100m 200m 500m 1 2 5 10 20 50 100 200 300 0 2k 4k 6k 8k 10k 12k 14k 16k 18k 20k 22k
W Hz
TIM vs. output power. RL = 4Ω, TIM FFT analysis. RL = 4Ω, PO =10W.
TIM@10W = 0.006%
Note that this limitation will never cause problems when the amplifier is fed a music signal at the input, but the limit must be
taken into consideration when the amplifier is tested under laboratory conditions using sine waves or noise signals.
Output Impedance
The output impedance is measured by feeding 1ARMS into the output of the amplifier and measuring the voltage on the output.
The voltage then corresponds to the output impedance. The output impedance is measured directly on the terminals on the
PCB.
The figure below shows the output impedance from 100Hz – 20kHz BTL-mode (left) and for one channel in SE-mode (right).
300m 600m
280m 550m
260m
500m
240m
450m
220m
200m 400m
180m 350m
160m
V V 300m
140m
250m
120m
100m 200m
80m 150m
60m
100m
40m
50m
20m
Figure 9: Measured voltage at output terminals while feeding 1ARMS into the output of the amplifier at PCB.
Loading
With its low output impedance, the ICEpower125ASX2 is designed to be unaffected by loudspeaker loading characteristics.
However, care should be taken with purely capacitive loads.
Traditionally amplifiers have been tested extensively in laboratories with purely capacitive loads. This was done to test the
amplifier’s stability and performance but it does not relate to any normal speaker load as even electrostatic speakers do not
present a purely capacitive load to the amplifier but include a resistive part as well. The maximum purely capacitive load al-
lowed is 390nF per channel in SE-mode or 220nF in BTL-mode.
DATASHEET
ICEpower125ASX2
Page 19 of 31
Version 1.3
SE-version
Continuous output
power 4 70 98 70 28
Continuous output
power 8 200 239 200 39
Features
The ICEpower125ASX2 has a number of useful features described below.
Enable pin
The enable pin can enable/disable the amplifier. If the pin is
left unconnected, then the level is high (+5V) and the ampli-
fier is enabled. If the pin is pulled low (0V) externally, the 10k
100R
amplifier will be disabled. Enable
The enable pin will also be pulled low by the internal pro-
C
tection circuitry if the amplifier temperature becomes too
high or a mains under- voltage is detected. This pin is bidi- GND
rectional.
GND GND GND
NOTE:
The Vd and Vs outputs are fused. Even brief overloads or Figure 14: Auxiliary supply equivalent diagram.
short circuits will blow the fuse!
Version 1.1
Protection Features
The ICEpower125ASX2 is equipped with several protection features for surviving overload without
damage. The block diagram below illustrates the different protection features.
The temperature protection will be activated if the absolute temperature of the circuit is too high.
This can be caused by high ambient temperature, high load (amplifier and AUX supply) for a long
time or a combination of these two parameters.
The overcurrent protection will be activated if the output current to amplifier and/or AUX exceeds the
limits. Please remember that the AUX supply is protected by a fuse which will blow if the supply is
overloaded.
If one of these protection features is triggered, the power supply either limits its output power or
shuts down. In case of a shutdown, the power supply will rapidly try to restart if the circuit’s temper-
ature is acceptable.
Page 24 of 31
DATASHEET
ICEpower125ASX2
Version 1.2
The HF protection circuit is implemented to protect the Zobel network against ultrasonic signals
(greater than 20kHz). This protection circuit has a built-in time constant, so it is possible to deliver a
high frequency, high amplitude signal for a short time.
The over temperature protection will only occur if the PRMS is greater that the specified Continuous
Output Power. In normal use, the amplifier will not shut down if properly mounted.
The overcurrent detection circuit is included in the ICEpower chipset by detecting saturation of the
control system. This condition will typically be allowed for 100ms to 500ms which is enough to avoid
accidental shutdown at peak currents during high music output. The current limit is set to 30A.
Input/Output Interface
Input Stage
DATASHEET
ICEpower125ASX2
Version 1.2
Output stage
The output stage is a half bridge topology with a 2nd
order filter. The filter design is a part of ICEpower’s
proprietary MECC topology and has been chosen as
the optimal solution between demodulation charac-
teristics, efficiency and filter compactness. The es-
sential output characteristics are:
DATASHEET
ICEpower125ASX2
Version 1.2
1. 570ms
2. 30ms
3. 200us
4. 30ms
5. Up to 2 seconds (Pout dependent)
6. 30ms
Thermal Design
Thermal design is generally a great challenge in power amplifier systems. Linear amplifier designs
operating in class A or AB are normally very inefficient and therefore equipped with extensive heat
sinking to keep the transistor junction temperature low. The ICEpower125ASX2 is based on highly
efficient ICEpower switching technology providing high overall efficiency characteristics at all levels
of operation.
The ICEpower125ASX2 module is designed for music reproduction, which means that the output
power of the amplifier will never be continuous. Research has shown that the RMS level of any music
signal does not normally exceed 1/8th of the peak value and the power supply is therefore designed
for large short-term power handling and lower continuous power handling. If the average output
power of the ICEpower125ASX2 exceeds 65W @ 4Ω (SE-mode with both channels driven) or 70W @
4Ω (BTL-mode) for a long time at 25°C ambient temperature, the module will reach its maximum al-
lowable temperature and the temperature protection will be activated.
Further information about thermal design can be found in the ICEpower ASX designer’s manual.
Page 27 of 31
DATASHEET
ICEpower125ASX2
Version 1.2
Physical Dimensions
All dimensions are in mm.
DATASHEET
ICEpower125ASX2
Version 1.2
Important! A minimum clearance of 12 mm. around the module is required for safety and ventilation
reasons.
DATASHEET
ICEpower125ASX2
Version 1.2
Drill Pattern
All dimensions are in mm. The diameter of the mounting holes is 3.5 mm and max. height above the
PCB is 31 mm.
DATASHEET
ICEpower125ASX2
Version 1.2
Safety Standards
The ICEpower125ASX2 is safety approved by CSA to ease the design-in procedure. The module com-
plies with the following standards:
Safety Class
ESD Warning
ICEpower products are manufactured according to the following ESD precautions:
• IEC 61340-5-1: Protection of electronic devices from electrostatic phenomena. General Re-
quirements.
• IEC 61340-5-2: Protection of electronic devices from electrostatic phenomena. User Guide.
• ANSI/ESD-S20.20-1999: Protection of Electrical and Electronic Parts, Assemblies and
Equipment.
Further handling of the products should comply with the same standards.
The general warranty policy of ICEpower a/s does not cover ESD damaged products due to improper
handling.
Storage humidity
Do not expose the pallets to humidity levels higher than 85% or rain.
Storage temperature
The pallets are to be stored at temperatures from 0°C to 70°C.
Page 31 of 31
DATASHEET
ICEpower125ASX2
Version 1.2
Stacking
Pallets may not be stacked on top of each other.
Notes
For additional information about the ICEpower® technology from ICEpower a/s, visit our web site or
contact us.
ICEpower a/s
Gl. Lundtoftevej 1b
DK-2800 Kgs. Lyngby
Denmark
Website http://www.ICEpower.dk
E-mail info@icepower.dk
Notice
The data sheet contains specifications that may be subject to change without prior notice. ICE-
power® is a trademark of ICEpower a/s.
ICEpower a/s products are not authorized for use as critical components in life support devices or
life support systems without the express written approval of the president and general counsel of
ICEpower a/s. As used herein:
1. Life support devices or systems are devices or systems which, (a) are intended for surgical
implant into the body, or (b) support or sustain life, and whose failure to perform when
properly used in accordance with instructions for use provided in the labelling, can be rea-
sonably expected to result in a significant injury to the user.
2. A critical component is any component of a life support device or system whose failure to
perform can be reasonably expected to cause the failure of the life support device or sys-
tem, or to affect its safety or effectiveness.