Vous êtes sur la page 1sur 3

Normal Operation LED indications Description

Tx-LED

DC-POW-LED

RX-SIG-LED

RX-SYNC-LED

AVR-ACT1-LED

AVR-LINK1-LED

AVR-ACT2-LED

AVR-LINK2-LED

PORTAB-TxD-LED

PORTAB-RxD-LED
G
DC Power
R
Radio Transmit
G
Radio Sync
R
Radio No Sync
G
LAN1 Link
O O
LAN1 Activity
G
LAN1 Link
O O
LAN1 Activity
G
Port A/B Receive
R
Port A/B Transmit

Informational LED indications Description


Tx-LED

DC-POW-LED

RX-SIG-LED

RX-SYNC-LED

AVR-ACT1-LED

AVR-LINK1-LED

AVR-ACT2-LED

AVR-LINK2-LED

PORTAB-TxD-LED

PORTAB-RxD-LED
• Firmware upgrade LED sequence
flashes 1sec on, 1sec off
• Factory defaults LED sequence
permanently on during return to defaults

Firmware upgrade O O O O O O O O O O Firmware update in progress


Factory defaults G G G G G Revert to factory defaults in progress

Filename: M:\Proj\EP189-IP Radio\Documentation\Source\Product Engineering Specification\Superceded\189-40-0002O - PES.doc

Document Number: 189-40-0002, Ver: O, Rev : 75, Last Edit : 23/12/2009 09:42:00 Page 19 of 56
6.4 Error Indicators
Errors are indicated by the Pwr/Tx, Sync/RxSig and RxD/TxD flashing red for 1 second, followed by an error specific sequence of green LEDs
flashing for one second. This cycle continues until all the error conditions have been cleared. Errors are indicated as follows:
Fatal Error LED indications Decription

Tx-LED

DC-POW-LED

RX-SIG-LED

RX-SYNC-LED

AVR-ACT1-LED

AVR-LINK1-LED

AVR-ACT2-LED

AVR-LINK2-LED

PORTAB-TxD-LED

PORTAB-RxD-LED
• Fatal error LED sequence flashes 1sec
on, 1sec off

J-Series Config corrupt, unrecoverable R R R R R


Jseries config corrupted (current and default).
O-Series Internal supply rail error R R R R R
Oseries internal supply rail error
O-Series Bad radio code store R R R R R
Code store crap
O-Series Radio file system corrupt R R R R R
Oseries user page configuration is corrupted??

Series Error LED indications Decription


Tx-LED

DC-POW-LED

RX-SIG-LED

RX-SYNC-LED

AVR-ACT1-LED

AVR-LINK1-LED

AVR-ACT2-LED

AVR-LINK2-LED

PORTAB-TxD-LED

PORTAB-RxD-LED
• Series error LED sequence flashes 1sec
red and 1sec green error code

O-Series Synth unlocked R R R R R G Main or aux PLL not locked


O-Series Old protocol error R R R R G R Jseries receives data from a radio not using the
FAR layer.
O-Series Config record not found R R G R R R Oseries configuration record not found
O-Series High VSWR R G R R R G R Ant 1 or 2 reporting high VSWR
O-Series High temperature R G R G R R G R Module temperature exceeded threshold

Filename: M:\Proj\EP189-IP Radio\Documentation\Source\Product Engineering Specification\Superceded\189-40-0002O - PES.doc

Document Number: 189-40-0002, Ver: O, Rev : 75, Last Edit : 23/12/2009 09:42:00 Page 20 of 56
O-Series External voltage R G R G R R G R G External voltage out of limits
O/J-Series Undefined error R R R G R R Undefined radio error
J-Series Config corrupt revert to defaults R R R G R R G Jseries configuration corrupted (current),
reverting to default configuration.
J-Series IP address not set R R R G R G R No ip address assigned to device
O-Series TxSync Slave has lost sync G G Slave has lost sync

Filename: M:\Proj\EP189-IP Radio\Documentation\Source\Product Engineering Specification\Superceded\189-40-0002O - PES.doc

Document Number: 189-40-0002, Ver: O, Rev : 75, Last Edit : 23/12/2009 09:42:00 Page 21 of 56