Vous êtes sur la page 1sur 2

Crompton Greaves Ltd.

RADIX Series Unitized Sub Station

Product Overview Salient Features


4
Protection from unauthorized access.
Unitized substation (USS) is a compact product comprising of various
substation equipment housed inside a metal enclosure. 4
Protection from environmental hazards.
4
Compact design with enhanced safety aspects.
The USS comprises of –
4
SCADA compatibility.
4
HV compartment consisting of a Vacuum Circuit Breaker (VCB) / 4
Appealing aesthetics with long Product life.
Ring Main Unit (RMU) / GIS. 4
Ease of operation & maintenance.
4
Transformer (X’MER). 4
Ready to charge.
4
Fully type tested as per IEC.
4
Low Voltage (LV) compartment consisting of LV distribution panel.

Technical Data Standard Variants


Degree of Protection IP 23D*
TYPE-1 TYPE-2
Duty Indoor / Outdoor RMU LV DIST
RMU LV DIST
Type of Ventilation Natural LV
ACB
LV X' MER
X'MER ACB MV
Standard Colour CG Blue # MV
MCCB
MCCB

Rated Voltage 12 kV/24kV/36kV MV METERING


UNIT

Rated Power Frequency withstand Voltage 28 kV/50kV/70kV


Rated lightening Impulse withstand Voltage 75 kV/95kV/170kV
TYPE-4
TYPE-3
Temperature Class K 10 RMU
RMU LV DIST
LV DIST
LV
ACB
Earthing system upto 26.3kA X' MER
LV
ACB X'MER
MV
MCCB
MV APFC
MCCB
* Higher degree of protection shall be provided on request. APFC

# Other color shades shall be provided on request. MV METERING


UNIT
Unitized Sub Station RADIX Series

Enclosure Vacuum Circuit Breaker Upto 12kV


4
All equipments mounted on a common galvanized GI base with 4
CG make horizontal draw out type VCB.
fabricated enclosure. 4
Complete SCADA Compatible solutions.
4
Painted with polyurethane rust proof paint. 4
CG make relay & Circuit Breaker Manager.
4
Completely detachable side walls, ensuring ease of access to all Gas Insulated Switchgear Upto 36kV
equipments.
4
Sealed for life breaker compartment.
4
Louvers are provided for cross ventilation to allow natural cooling
4
Virtually maintenance free equipment.
inside enclosure.
Transformer Compartment
4
Enclosure doors are individually pad lockable from outside and are
interlocked to secure all doors by bolting LT Compartment door. 4
Choice of Oil cooled or Dry type transformer.
4
All busbars inside the cubicle are sleeved using heat shrinkable 4
Rating: Upto 1600kVA with Voltage: 12 kV/22kV/33kV.
sleeves. 4
Optional Off Circuit / On Load tap changer arrangement.
4
Enclosure lifted directly from base frame by means of specially 4
Oil filled transformer - Hermetically sealed / Corrugated tank.
designed detachable lifting arrangement ensures no
distortion/damage to the enclosure during lifting/handling. 4
Primary connection from transformer by XLPE cable & secondary
connections by solid flats with expansion joints ensures proper
4
Compact layout of Transformer, LT & RMU inside enclosure and joints and avoids stress / impact on transformer bushings.
yet without compromising access for maintenance.
LV Compartment
HV Compartment
4
Rating upto 2500 A, 440 V.
SF6 Gas filled Vacuum RMU Upto 36kV
4
LV Switchgear: ACB / MCCB feeder board upto 12 feeders.
4
CG make RMU with side cable entry & rear Tee-off bushings helps
4
Optional APFC panel with capacitor bank.
in direct & easy coupling of RMU with Transformer.
4
Optional Metering Unit (MU).
4
SCADA compatibility.
4
Fault passage / Earth Fault indicators. Handling of a fully assembled unit

Dimensions
DIMENSIONS (mm)*
COMBINATION L W H
RMU + X'MER + LT 3400 1900 2275
RMU + MU + X'MER + LT 3900 2200 2450
RMU + X'MER + LT + APFC 3550 2200 2575
* The mentioned dimensions are indicative as they are subject to
change based on equipment ratings, layout & total no. of LT
outgoing feeders.

Crompton Greaves Ltd.,


Power Systems : M. V. Switchgear Division (S2)
A-3, MIDC, Ambad, Nasik - 422 010. India.
Tel. : +91 253 2382271 to 75
Email : mv.switchgear@cgglobal.com L
Registered Office
W
CG House, 6th Floor, Dr. Annie Besant Road, Worli, Mumbai- 400 030.
www.cgglobal.com