Académique Documents
Professionnel Documents
Culture Documents
Notes
10/12/2014 17:14:30
1.This drawing is to be read in conjunction with the
relevant Architectural drawings and specifications,
and relevant documents by others.
1
2.For building setting out refer to Architects
drawings.
3
150 150 Concrete 'plinth' required where top of pile
level is less than underside of pilecap
50mm Blinding
3 x pile dia typically spacing. UNO 3 x pile dia typically spacing. UNO 3 x pile dia typically spacing. UNO
TBC by contractor design TBC by contractor design TBC by contractor design
5
1 Typical Pile - Pile Cap Detail: Pile cut off within pile cap 2 Typical Pile - Pile Cap Detail: Pile cut-off below pile cap
1 : 50 1 : 50
P2 10/12/14 JS SC DE
Issued for inclusion in planning submission
P1 09/12/14 JS SC DE
Issued for information in pile tender package
Rev Date By Chkd Appd
8 Fitzroy Street
London W1T 4BQ
Tel +44(0)20 7636 1531 Fax +44(0)20 7580 3924
www.arup.com
Client
Project Title
Drawing Title
10 PILE CAP DETAILS
Scale at A1
1 : 50
Role
STRUCTURAL
Suitability
PLANNING
Arup Job No Rev
11
237038 P2
Name
S-160-DE-PF-001