Transformer A to Z Testing

Oil PD Test

Accuracy
Gas

Winding/
Insulation Re-Winding

C+DF
Ratio

Winding
HV Test
Resistance

MULTI-TEK INTERNATIONAL
103 – 105 Freston Road (Industrial Area), London W11 4BD,England
Tel.: +44-(0)20-73133190 • Fax.:+44-(0)20-73133191
E-Mail: mti@multitekintl.com
J 2007/2008
(2008/2009)

Item Description

1 General Purpose Electrical Test Equipment for Transformers

1A Multimeter type AVO310 with backlit LCD display, min/max store,


analogue bar graph and standard accessories

1B Multifunction Installation Tester type MFT1552 complete with standard


accessories

1C Power Clampmeter type VA6200 complete with Software

1D Insulation Tester up to 1KV type MIT420 with Standard Accessories

1E Insulation Tester up to 10KV type MIT1020/2 complete with all


standard accessories.

2 Winding Resistance Testing

2A Transformer Ohmmeter / Winding Resistance and Tap Changer Test


Set type MTO210 complete with test lead set

2B Digital Low Resistance Ohmmeter type DLRO10X (10A / rechargeable)


including memory / download functions, with standard accessories

2C 5kV Impulse Winding Tester with Graphic Display type R8228-5

3 Transformer Turn Ratio Testing

3A Fully Automatic Single and 3 Phase Transformer Turns Ratio Test Set
type TTR300 Series compete will all standard accessories.

3B Single Phase Hand Held Transformer Turns Ratio test set type
TTR100 with standard accessories

3C Hand Held Transformer Turns Ratio test set type TTR25 with standard
accessories
(2008/2009)
Item Description

3D Single-phase Hand-cranked Transformer Turns Ratio Test Set type


550005 complete with standard accessories

3E Portable Digital Ratio meter type RTD/3

4 Capacitance + Dissipation Factor (Tan Delta) Test Sets

4A Tangent Delta / C+DF Test Set type Delta2000 complete with 12kV HV
supply, all standard accessories, RS232 interface and software, hot
collar straps and tap connectors, operation voltage 230V AC, 50Hz

4B 10kV Automatic Power Factor Test Set with “PowerDB software” type
Delta 3000 complete with all standard accessories.

5 CT / PT & Meter Testing

5A Current Transformer Tester type MCTT-10 complete with all standard


accessories

5B Automatic CT Saturation, ratio, polarity, demagnetizing, burden and


insulation test set type MCT1600.

5C Portable current instrument transformer tester type PTT2.1 with


standard accessories

5D Three Phase Portable Meter Reference Standard type PWS2.3 PLUS


class 0.1 for Meter Testing as well as CT / VT Testing complete with
Test leads, Three 100 Amp Clamps, Scanning Head & Software

6 Computerised Power & Distribution Transformer Evaluation


and Test System.

6A Automatic Power Transformer Test Set Type ETP SYSTEM complete


with software.
(2008/2009)
Item Description

7 Transformer Frequency Response Analyzer:

7A Transformer Frequency Response Analyzer type FRAX101 complete


with all standard accessories

7B Insulation Diagnostic Analyzer (Capacitance and Dissipation


Factor/Water content) for Power Transformers type IDEX300 with all
standard accessories and software (AG-19090)

8 PD Measurement for MV and HV. (Applicable to latest


measurement on Switchgear & Transformer)

8A PD Level Indicator type PD Surveyor complete with accessories

8B Online & Offline PD Test Equipment for Testing of Medium Voltage


Transformer consisting of:

- Partial Discharge Test Hardware type OSM


Longshot – WR Xi (4-ch PD Analyser) with HFCT Sensor, TEV Probes,
Mini Pulse Generator, 36kV, 850pF High Voltage Coupling Capacitor,
Variable Gain Amplifier, Test Cables

- Hardware Package Includes Carry Case, Mini Keyboard, Optical


Mouse & Mouse mat and 80GB USB Portable Hard Disk (for storage
and transfer of PD Gold data files).

- Partial Discharge Test Software type PD Gold + PD Reader (Data


Analysis Software) + PD Waveform Capture & Analysis Software

Option - AC High Voltage Low Discharge System for Offline Testing


can be provided on request.

9 Transformer Oil Dielectric Test Set

9A Fully Automatic Oil Test Set type OTS100AF/2 with all standard
accessories
(2008/2009)
Item Description

10 Transformer Oil Moisture Test Set

10A Portable Moisture in Oil Test Set type KF-UNI complete with all
standard accessories

11 Transformer Oil Treatment Plant

11A Transformer Oil treatment plant (3000L/H capacity) type THV3000


complete with standard accessories
Note: Other Versions with different Capacities can be provided on
request.

12 Gases and Transformer Oil (Portable GC for detection of 11


Gases)

12A Dissolved Gas Analyzer for transformers according to DIN/IEC567 type


Mobil GC version2, consisting of :
-GC with TCD, one channel column, automatic injector valve, Software
for detection of 11 fault gases in 19” portable case
- 2 Detector FID (Flame Ionisation detector) for more
-accurate detection of hydro carbons
- Methanizer (filled with catalytic powder)
- 2. column ( Molesiev column 30m x 0,53mm
inner diam.) for detection of O, N, H2
-column switch for autom. Measurement. Procedure
-Autom. sample loop with dosing valve, fixed dosing volume
-Internal carrier gas supply for approx. 80 h of operation
-Internal burning gas supply for approx. 80 h of operation H2
-Partial vacuum degassing according to DIN/IEC 567 consists of:
Oil syringe incl. access.
3 port valve
gas volume syringe
gas injection syringe
rubber caps
-Software and Expert system for autom. measurement procedure
-Operating manual
-Transport case
(2008/2009)
Item Description

12B Dissolved Gas Analysis with Automatic Degassing unit According to


IEC567 /ASTM 3612 type Top Toga GC.

13 Transformer Fault Indicator (Online Monitoring)

13A Transformer monitoring unit type Hydrocal1002 complete with


Hydrosoft software for data transfer and data administration

13B Transformer monitoring unit type Hydrocal1003 as Hydrocal 1002 but


with additional Water in oil/ moisture measurement.

14 High Voltage Lab for AC, DC and Impulse Testing can be provided
on request.

15 Transformer Electrical Workshop

A complete transformer repair workshop including Winding / Rewinding


Coil Winding Machines, Ovens, Essential Tools and other Accessories
can be provided on request.
1.General Purpose
Electrical Test Equipment
for Transformers
Item 1A
AVO300
Digital Multimeter

AVO300
Digial Multimeter

■ Designed for Electricians


■ Fully auto ranging
■ Large display characters
■ Separate battery and fuse cover
■ Data hold
■ Min/Max store
■ IEC 61010 compliant
■ Suitable for applications to CATIII 600 V

DESCRIPTION Large clear display


The AVO300 range of Megger digital multi-meters are tough The LCD display has large high contrast 31/2 digit display
compact instruments designed for the contracting electri- which are easily read from a distance. Additionally the
cian, but are also suitable for a wide range of AVO310 has a backlit LCD for use in poor lighting and a bar
applications and users. graph range showing the percentage of range used.
Both instruments offer a range of measurement modes Data HOLD
for AC and DC applications, resistance and current This allows a displayed result to be held on the display until
measurement. needed, rather than trying to remember a measurement.
The result will be held until the HOLD button is pressed
The AVO300 series multi-meters have tough rubber again, or until the unit switches off.
armoured cases offering the maximum amount of
protection from the extreme use found in modern MODE
industrial environments. They draw on extensive When making current measurements the mode function
experience of Megger engineers in designing safe reliable allow the selection of AC or DC measurement.
instruments for the electrical industry.
MAX/MIN (AVO310 only)
Neither of the instruments are burdened with functions that The Max/Min function on the AVO310 freezes the maximum
never get used. This keeps the instruments simple to oper- or minimum measured result on the screen. The display
ate without the continued need to refer to the user manual. does not have to be continually watched to capture a
momentary increase or fall in circuit voltage, resistance or
Auto-ranging
current.
Every measurement range is fully auto-ranging. Simply
switch on the instrument and start testing, leaving hands Voltage measurement
free for holding probes, or hanging onto ladders. Both AC and DC voltage measurement is possible with the
instrument auto ranging to match the voltage at the test
Separate Battery/Fuse compartment
probes.
The battery and fuse compartment are accessed by a sepa-
rate cover on the back. This allows both battery and fuses to Voltage measurements up to 1000V are permitted without
be replaced without opening the main instrument body, and damage to the instrument.
if the meter is sealed with a calibration seal, will not break
Current measurement
the seal and invalidate the calibration. A problem found on
Three ranges are provided for current measurement of
most commonly available multi-meters.
either AC or DC current from 0.1uA to 10A. Fused inputs
protect both the user and the instrument in the case of
excess current.
AVO300
Digital Multimeter

Resistance, continuity and Diode testing SPECIFICATIONS


Resistance can be measured directly on the ohms range Technical:
from 0ohms up to 1.999Mohms. A continuity buzzer range is Insulation:
also available for checking low resistance between two Class2, Double insulation.
points. The buzzer sounding if the resistance is less than
50ohms (35ohms on the AVO310).
Overvoltage category: (AVO300/310)
Additionally a diode range exists for testing forward and CATIII 600V / CATII1000V
reverse bias operation of transistors and diodes.
Additional features Display
A low battery indicator warns when batteries are low, and an AVO300:
auto-off function ensures no unnecessary battery wastage 4000 counts LCD display, 25.4mm high
occurs if accidentally left on. AVO310:
A built-in rear stand provides both a bench stand for com- 4000 counts LCD display, 20mm high
fortable use on the bench, as well as extending round 180°
to act as a hanging bracket.
Backlight
AVO310 only
Product selection table AVO300 AVO310
Technical Features
Polarity
AC Voltage 1000 V 1000 V Automatic, (-) negative polarity indication.

DC Voltage 1000 V 1000 V


Over-range
AC Current 10 A 10 A "OL" mark indication.
Low battery indication: A Battery symbol is displayed when the
DC Current 10 A 10 A battery voltage drops below the operating level.

Resistance 0.1 Ω to 40 MΩ Y Y
Measurement rate
Diode test Y Y 2 times per second nominal.
Fast continuity buzzer Y Y
Auto power off
Auto-ranging Y Y AVO300:
Meter automatically shuts down after approx. 15 minutes of
Data-hold Y Y
inactivity.
Max/Min - Y
AVO310:
Backlight - Y
Meter automatically shuts down after approx. 30 minutes of
Tough Rubber Armoured case Y Y inactivity.

Separate fuse and battery cover Y Y Operating environment

Integral Stand/Hanger Y Y -10 ºC to 50 ºC (14 ºF to 122 ºF) at < 70 % relative humidity.

Probe holder Y Y Storage temperature


Auto power down Y Y -30 ºC to 60 ºC (-4 ºF to 140 ºF) at <80 % relative humidity.

Battery Low Warning Y Y


Relative humidity
Base Accuracy 1% 1% 90% (0ºC to 30ºC); 75%(30ºC to 40ºC); 45%(40ºC to 50ºC)

Battery type 9V PP3 (LR61)


For inside use,
max height
Temperature -10˚C to +50˚C
Operating:3000m
Installation category 600V CATIII Storage 10,000m

IEC 61010 Y Y
Pollution degree 2
AVO300
Digital Multimeter

Safety AC Current (Auto-ranging)


The instrument complies with EN61010-2-32 Range Resolution Accuracy
400.0 µA 0.1 µA
Powe: 4000 µA 1 µA
+1.5% of rdg ±5 digits
One 9 V battery , NEDA 1604, IEC 6F22 40.00 mA 10 µA
400.0 mA 100 µA
Dimensions 10 A 10 mA +3.0% of rdg ±5 digits
182 (H) x 82 (W) x55 (D) mm Overload Protection: 0.5 A / 1000 V and 10 A / 1000 V Fuse.
AC Response: 50Hz to 400Hz
Weight: Approx Maximum Input: 4000 µA ac rms on µA
375g 400 mA ac rms on mA
10 A ac rms on 10 A range.
Accuracy
Accuracy is given at 18 ºC to 28 ºC (65 ºF to 83 ºF), less than 70 % Resistance [Ω] (Auto-ranging)
RH Range Resolution Accuracy
400.0 Ω 0.1 Ω +0.8% of rdg ±5 digits
DC Voltage (Auto-ranging) 4.000 kΩ 1Ω
Range Resolution Accuracy 40.00 kΩ 10 Ω
+0.8% of rdg ±2 digits
400.0 mV 0.1 mV +0.5% of rdg ±2 digits 400.0 kΩ 100 Ω
4.000 V 1 mV 4.000 MΩ 1 kΩ
+3% of rdg ±8 digits
40.00 V 10 mV +0.8% of rdg ±2 digits 40.00 MΩ 10 kΩ
400.0 V 100 mV Input Protection: 1000 V d.c. or 1000 V a.c. rms.
600 V 1V +1% of rdg ±2 digits
Input Impedance: 7.8MΩ. AVO300: Diode Test
Maximum Input: 1000 V d.c. Test current Resolution Accuracy
0.3mA typical/Open
AC Voltage (Auto-ranging) <1.5 V 1 mV +10% of rdg ±5 digits
Range Resolution Accuracy Open circuit voltage: 1.5 V dc typical
400.0 mV (AVO310 only) 0.1 mV
Overload protection: 1000 V d.c. or 1000 a.c. V rms
4.000 V 1 mV
+1% of rdg ±5 digits
40.00 V 10 mV AVO310: Diode Test
400.0 V 100 mV Test current Resolution Accuracy
1000 V 1V +1.5% of rdg ±5 digits 1mA typical/
Input Impedance: 7.8 MΩ. Open MAX.3 V 1 mV +10% of rdg ±5 digits
AC Response: 50Hz 60Hz Open circuit voltage:
MAX. 3 V dc
Maximum Input: 1000 V rms
Overload protection: 1000 V d.c. or 100 V a.c. rms

DC Current (Auto-ranging)
Audible continuity
Range Resolution Accuracy
Audible threshold:
400.0 µA 0.1 µA
AVO300:
4000 µA 1 µA
+1.0% of rdg ±3 digits Less than10 ohm to 30 ohm Ω
40.00 mA 10 µA
Test current: MAX. 0.3 mA
400.0 mA 100 µA
AVO310:
10 A 10 mA +2.5% of rdg ± 3 digits
Less than 35 ohm Ω
Overload Protection: 0.5 A / 1000 V and 10 A / 1000 V Fuse.
Test current MAX. 1.5 mA
Maximum Input: 4000 µA dc on µA range
Overload protection: 1000 V d.c. or 1000 V a.c. rms
400 mA dc on mA range
10 A dc on 10 A range.
AVO300
Digital Multimeter

ORDERING INFORMATION
Item (Qty) Order Code
Digital multimeter CATIII 600V AVO300
Digital multimeter CATIII 600V with Min/Max and backlight AVO310
Included Accessories
Test leads and Probes
Optional Accessories
Replacement Red/Black Test lead set 6220-779
Fused Red/Black test lead set 6220-789
Item 1B
MFT1500 Series
Combined Insulation, Loop & RCD Tester

MFT1500 Series
Combined Insulation, Loop & RCD Tester

■ Combined 16th Edition testing


■ Guaranteed non-tripping loop test range
■ Backlit display and selector ranges
■ Automatic RCD testing (MFT1552 &
MFT1553 only)
■ Bluetooth downloading (MFT1553 only)
■ Illuminated switch probe
■ Selectable touch voltage
■ Touch (fault) voltage and display
■ Calibrated earth loop test lead
■ Calibration certificate

DESCRIPTION FEATURES
The MFT1500 series multifunction tester has been revised to The MFT1500 series uses the patented Megger digital/
include some additional new features: analogue arc display. The analogue arc provides an
indication of fluctuating readings, while the digital readout
Called the MFT1500 series, they retain all the essential
providing the ability to record accurate results.
features necessary for testing domestic, commercial and
industrial fixed wiring, and now include the following: All test functions are selectable from the main panel, with
no hidden ranges or functions to forget.
■ PFC measurement on both loop test ranges
Special functions include:
■ Selectable Fault (Touch) voltage 25 V or 50 V
■ Fault (Touch) voltage display
VOLTAGE MEASUREMENT
■ New Megger lead set included with all instruments
■ AC/DC Volt meter provides a means of measuring the
■ DC test functions for RCDs supply voltage independently of any other test functions,
eliminating the need to carry a separate multimeter.
All instruments test in accordance with International
Automatic selection of AC or DC measurement up to
Standards and National Wiring Regulations including BS7671
500 V a.c./d.c.
(16th Edition wiring regulations) and European Standard
EN61557.
CONTINUITY TESTING
In addition, the MFT1500 series also meets or exceeds the
requirements of EN61010-1 Category III 480 V (max) phase- ■ 200 mA continuity from 0.01 1 to 99.9 k1 exceeds all
phase. current requirements for testing final ring circuit
conductors, and bonding of services.
The MFT1500 is available in 4 options, the standard
■ Automatic continuity testing commences the moment
MFT1501/2 the MFT1502/2 which includes useful additional
the test probes touch the circuit to be tested, allowing
facilities such as backlit display and range switches, plus the
fast testing with both hands free.
unique Megger illuminated switched probe, the MFT1552
which has an automatic RCD test feature, and the MFT1553 ■ Fast continuity buzzer is a fast buzzer tone, with no
which has Bluetooth downloading capability delay on each test for the buzzer to sound, saving
valuable operator time. This test includes a fast safety
The unique modern styling of the instruments allows it to check for the presence of a voltage as the test probes
be operated whilst stood on the floor, a ledge, hung around are connected to the circuit.
the neck with the supplied neck strap, or held in the hand.
MFT1500 Series
Combined Insulation, Loop & RCD Tester

■ Variable buzzer threshold controls the limit at which RCD TESTING:


the continuity buzzer stops sounding. Selected from 2 1
to 100 1 in 6 steps. ■ 10 mA to 1000 mA RCD ranges. All standard RCDs
from 10 mA to 1000 mA are fully supported. All standard
■ Lead null stores the test lead resistance and deducts this RCD test functions are available with both 0° and 180°
value from the continuity result, even if the instrument is phase angle at 1/2I, I and 5I up to 300 mA.
switched off. Thus reducing the chance of possible
measurement errors. ■ RCD ramp test measures the RCD trip current. The
ramp test displays the actual trip current on all RCD
ranges instead of trip time. Ideal for identifying nuisance
Insulation testing: tripping RCDs. The current is stepped up from 1/2I to I in
■ Insulation test at 250 V, 500 V and 1000 V for testing 200 ms steps.
low voltage applications. A 1000 V warning is issued ■ Fault (Touch) voltage can now be set for either 25 V or
prior to performing the 1000 V insulation test. 50 V depending on application.
■ Live circuit warning when performing insulation or ■ Fault/touch voltage can also be displayed up to 100 V on
continuity measurements a live circuit warning is a selectable bargraph.
displayed and an audible warning sounded if connected ■ DC sensitive, RCD test option enables testing at 1/2I,
to a circuit with a voltage greater than 25 V (15 V for I and 5I.
continuity testing).
■ Safety lockout at voltages greater than 55 V during GENERAL FEATURES:
continuity and insulation testing, the instrument
automatically warns the operator and inhibits any ■ Quick to pick up and use by using colour coded
testing, preventing accidental damage to the instrument ranges and no hidden functions the MFT1500 series takes
and full protection to the operator. minutes to learn how to use. Function buttons are
■ The ‘Auto discharge’ facility safely discharges all colour matched to the test mode to ensure easy
circuits after an insulation test, preventing accidental operation.
shock from a stored charge on a long cable during or ■ Visible and audible Safety warning features are
after disconnection. paramount with live circuit warning and protection
circuitry. If live voltages exist on a circuit during
LOOP TESTING insulation or continuity testing the voltage is displayed
on the screen. If this voltage exceeds a safe level, the
■ Low current loop test is a 3 wire non-tripping MFT1500 series inhibits further testing and a warning
0.01 1 loop test designed to prevent RCD tripping by beeper sounds for extra safety.
using a sophisticated 15 mA loop test pioneered by ■ Large easy-to-read LCD using the patented Megger
Megger Limited. This NO-TRIP test ensures the RCD will digital/analogue arc technology - combining high speed
not trip whilst performing a loop impedance test. analogue clarity with digital stability. Making it easy to
■ High current loop test at 25 A provides a fast loop test read even in low light level.
where no RCD is fitted, or for Ze measurement on the ■ Economical with batteries by incorporates an auto
incoming side of an RCD. shut off facility that operates after 5 minutes of inactivity,
■ Supply voltage and polarity indication upon reducing wasted battery consumption.
connection to the mains supply the polarity and voltage ■ Innovative test lead connection has been developed
are displayed to show correct wiring of the socket under for the MFT1500 series. The unique shutter system
test or test lead connections. This function also provides allows only those combinations of test leads permitted
a warning of live voltages while continuity or insulation for safe testing to be connected. Unsafe or unnecessary
testing. options cannot be connected.
■ Phase-Phase Phase-Neutral and Phase-Earth Loop Tests ■ Rubber over-moulded case. The ergonomic rubber
are possible. No danger of damage from accidental 3- moulding provides a secure comfortable hold, whilst
phase connection. providing maximum protection with IP54 weather proof
■ Wide supply voltage; allows loop measurements from rating.
55 V to 480 V. No damage if accidentally connected ■ Calibration certificate
across phases.
■ 3 year warranty
■ Prospective short-circuit current (PSC) A dedicated
PSC range, using either the 25 A high current loop test or
no-trip test, is provided for rapid measurement of Loop MFT1502/2 Additional features
currents, both at the socket outlet and distribution Illuminated switched probe shines a new light on
board. The PSC ranges from 1 A to 19.9 kA with a testing.
resolution of 1 A, 10 A and 100 A depending on range. All
the loop and PSC tests are auto-ranging. A fully featured test probe allows for single-handed
operation and test status indication. Probe features include:
■ Remote test button for single-handed testing in difficult
locations, the test button duplicates the instrument test
MFT1500 Series
Combined Insulation, Loop & RCD Tester

button in all test modes. Live circuit warnings


Insulation:
■ LED torch using a built-in WHITE LED light provides illu-
mination to the probe tip, providing essential lighting in 25 V threshold
low light conditions. Continuity:
■ Red/green status LED duplicates the warning display on >15 V threshold
the main instrument display. A RED LED indicates a
voltage present on an insulation range. A GREEN LED Insulation
indicates the instrument is displaying a valid test result. 25 V visual warning
■ Three interchangeable probe tips are supplied in 55 V visual, audible and test inhibit
standard shrouded, removable shrouded and an extended Phase to earth:
probe tip to provides the ideal probe tip option. >280 V visual, audible and test inhibit
■ Illuminated display and selector ranges. Not only the
backlight, but also the selector dials are illuminated to Continuity (to EN 61557-4)
allow for use in difficult low-light conditions. Range or Ohms:
0.01 1 - 99.9 1 (±2% ±2 digits)
function change automatically operates the backlight, or
by manual selection. 100 1 - 99.9 k1 (±5% ±2 digits)

■ Instrument and document carry case is supplied to


Buzzer
transport the instrument as well as any necessary test Selectable limits of 2 1, 5 1, 10 1, 20 1, 50 1, 100 1
leads, documents, drawings etc.
Open circuit voltage 4-5 V d.c.
Test current:
MFT1552 & MFT1553 Additional features
>200 mA @ 2 1
Selecting the auto (RCD) feature, starts the RCD test current Test Lead null:
cycle of 1/2I, I and 5I.
Up to 9.99 1 (zero uses Test Button)
Each time the RCD is tripped, resetting it, automatically
continues the test sequence. Loop test ranges (to EN 61557-3)
Line/Earth(Single phase)
Once completed, test results can be recalled on the
MFT1552 or MFT1553.
25 A
0.01 1 - 9.99 1 (±5% ±0.03 1)
MFT1553 Additional features 10.0 1 -89.9 1 (±5% ±0.5 1)
90 1 - 899 1 (±5% ±5 1 )
Using the Bluetooth function, download test results directly
into inspection certificates, within PowerSuite® running on 900 1 - 3.00 k1 (±5% ±20 1)
laptops and mobile devices for on-site certification. Supply:
Alternatively the data can be downloaded into Mobile 55 V - 280 V 45 Hz to 65 Hz
Download Manager for storage and later processing.
Phase to phase
25 A
SPECIFICATION 0.01 1 -1 9.99 1
(±5% ±0.03 1)
Supply Voltage range
Supply:
Voltage a.c.:
55 V - 480 V 45Hz to 65Hz
0 V - 500 V 50/60Hz ±2% ±2 digits
Voltage d.c.:
Low current Loop (NO TRIP)
0 V - 500 V ±2% ±2 digits
15 mA
Polarity indicated above 10 V 0.01 1 - 2.00 k1 (±5% ±0.03 ohms ± Noise Margin).
Supply:
Insulation test ranges (to EN 61557-2) 55 V - 270 V 45Hz to 65Hz
Short circuit current: <2 mA
250 V 0.01 M1 - 99.9 M1 Prospective Shortcircuit Current PSC
500 V 0.01 M1 - 299 M1 Prospective fault current = Nominal Voltage/Loop Resistance
1000 V 0.01 M1 - 499 M1 Accuracy is therefore derived from the loop test.
±2% ±2 digits up to 99 M1 1 A - 199 A 1 A resolution
250, 500 and 1 kV into 1 mA (BS7671, HD384 and IEC364) 0.02 kA - 1.99 kA 10 A resolution
Output voltage: +20% - 0% at rated load or less 2.0 kA - 19.9 kA 100 A resolution
MFT1500 Series
Combined Insulation, Loop & RCD Tester

RCD ranges (to EN-61557-6) Safety


Supply: Double insulated to IEC61010-1-2001, Installation Category III,
100 V - 270 V 45Hz to 65Hz 300 V phase to earth, 500 V phase to phase.

Ranges: In addition Probe designed to meet IEC 61010-031-2002, Double


insulated to Installation Category III, 300 V phase to earth, 500 V
1000 mA, 500 mA, 300 mA, 100 mA, 30 mA, 10 mA phase to phase.
Type: 1/2I - 1/2 times the selected RCD rated current.
EMC
I - One times selected RCD rated current.
In accordance with IEC 61326 including amendment No. 1
5I - Five times I RCD rated current.
RAMP - A ramp test that displays actual trip current . Environmental
Operating range: -5 to +40ºC
DC sensitive - A DC test current at 1/2I, I and 5I.
Operating humidity: 90% RH at 40ºC max
Current accuracy:
Storage temperature: -25 to 65ºC
No trip (1/2I) -8% to -2%
Maximum altitude: 2000 m
Trip (I) and 5I +2% to +8%
Dust and water protection: Instrument IP54, probe no rating
Trip time accuracy:
±1% ±1 ms Physical
Touch (Fault) voltage: 0 V to 100 V error ±5% to +15% ±0.5 V Dimensions:150 mm high x 85 mm wide x 235 mm deep

Selection: 25 V or 50 V (6 in. x 3.5 in. x 9.5 in.)


Weight:1440 gms (3lb)
Power supply
EN61557:
8 x 1.5 V Alkaline cells type LR6
Complies with the following parts of 61557, electrical safety in
Battery life: 2600 insulation tests with a duty cycle of 5 seconds
low voltage systems up to 1000 V a.c. and 1500 V d.c.-
on and 25 seconds off at 500 k1.
Equipment for testing, measuring or monitoring of protective
Fuses measures:-
Replaceable 500 mA (F) HBC 10 kA 500 V Part 1- General requirements
Non-replaceable 7 A (SIBA 70-065-63) x 2 Part 2- Insulation resistance
Non-replaceable 1 A Part 3- Loop resistance
Remote probe: MFT1502/2, MFT1552 and MFT1553 only Part 4- Continuity
Torch feature: 5mm WHITE LED 1500 mcd Part 6- Residual current devices (RCD)
Safety: CLASS 1 LED to IEC 60825:2001 Interchangeable tips Part 10- Combined measuring equipment
Battery: 1 x 9 V Alkaline cell type PP3
The Bluetooth word mark and logo are owned by the Bluetooth SIG. Inc.
Fuse: Non-replaceable 7 A (SIBA 70-065-63) and any use of such marks by Megger is under licence.

Item (Qty) Order No. Item (Qty) Order No.


Multifunction tester standard MFT1501/2 Additional accessories with MFT1502/MFT1552/MFT1553
Multifunction tester with illuminated switch probe As MFT1501/2 plus:
MFT1502/2 Illuminated switched probe
Multifunction tester standard (European) MTF1501/2E Instrument/document carry case
Multifunction tester with illuminated switch Optional accessories for MFT1500 Series
probe (European) MFT1502/2E PowerSuite On-site (MFT1553 only) 6111-777
Multifunction tester with automatic RCD testing MFT1552 Replacement 3 wire test lead set 6220-796
Multifunction tester with automatic Fused prod and clip set 6180-405
Bluetooth downloading MFT1553 Standard switched probe 6220-836
Accessories included with MFT1501 Illuminated switched probe 6311-089
User guide on CD 6172-831 Test lead with Schuko plug 6231-593
3 wire test lead Test lead with UK mains plug 6220-740
Crocodile clips (red, black and green) Test lead with USA mains plug 6220-643
Mains plug (BS1363) test lead Earth bond test lead set 6231-586
Instrument/document carry case 6420-143
Illuminated probe tip set 6121-562
Item 1C
Network mains analysis clamp

Total effective current – THD Harmonic current no.1 %


harmonic no.1 / fundamental component

Peak current – THD - Harmonic spectrum

Oscillogram U and I Phase angle ϕ

Reactive, active apparent power cos ϕ consumption

ref. VA6200
Three-phase diagram V1 V2 V3 I1 I2 I3 ϕ

The screen on this clamp can be used either as a numeric display or FUNCTIONS RANGES ACCURACY
as a graphical screen like an oscilloscope, or as a logging instru- IAC RMS 4.0 ~ 1500.0 A auto ranging 0.5% + 5 dgt
ment. The clamp measures the true RMS voltage and current, appa-
VAC RMS 4.0 ~ 600.0 V auto ranging 0.5% + 5 dgt
rent, reactive, active, balanced three-phase and single-phase power,
W - VA - VAR 1000.0 W - 10.000 - 100.00 - 1000.0kW 1% + 20 dgt
cosj, peak factor, total distortion, power consumption and maximum
power demand. Energy Wh kWh 0 Wh ~ 999 999 kWh (resp VAh &VARh) 1% + 20dgt
In graphics mode, it displays and quantifies the first 50 harmonics of Crest factor CF 1.00 - 99,99 5% + 30 dgt
the signal (simultaneously as a percentage of the fundamental com- Total harmonic distortion 0.0 ~ 1000.0 % 2% - 6% - 10% (as per range)
ponent and in volts, response in amperes), the form of the U and I Power factor cosϕ 0.000 - 1.000 0.04
signals, the single-phase and three-phase diagram. In logging phase angle - 180° ~ +180° 0.1°
mode, the clamp stores information in its memory. The sampling fre-
Harmonics of AC voltage Order 1 ~ 20th : 0.0 ~ 100.0% 2%
quency and the start/stop cues can be programmed. Long acquisi-
in V and in % Order 20th ~ 50th : 0,0 ~ 100.0% 4%
tions at high frequencies, with several simultaneous quantities, are
possible by using an RS232 output to a PC and special software. Harmonics of AC current Order 1 ~ 20th : 0,0 ~ 100.0% 2%
in V and in % Order 20th ~ 50th : 0.0 ~ 100.0% 4%

OTHER FUNCTIONS IAC and VAC transients Capture of transient events (32000)
Measurement of the maximum demand in kW and kVA
Programmable threshold for transient capture (128 events)
32 to 256 points/cycle can be saved on the internal memory
Memory size: 50,000 logs can be programmed based on a period of between 1 and 6000s.
Real time output of: oscillograms, power, settings and harmonics
Switches off automatically if not used

Optoisolated RS232 INTERFACE (8 bits, ASCII format) supplied as standard


System software for curve charts and numeric results on PC.

OTHER FEATURES
Opening of clamping jaws: 6 55mm
Dimensions/Weight: 270 x 100 x 45mm Weight 800g
Supplied with probes and a carry case

Products Guarantee 2 years


Item 1D
MIT400 CAT IV
Industrial Insulation Testers

MIT400 CAT IV
Industrial Insulation Testers
■ CAT IV 600 V applications
■ TRMS & DC Voltage measurement
■ Insulation testing up to 1000 V and
200 G1
■ Continuity testing at 200 mA or 20 mA
down to 0.01 1
■ Pass/Fail limit alarms
■ Combined Analogue and dual digital
display
■ PI/DAR and Timer function
■ Test result storage (MIT420)
■ Bluetooth® wireless data transfer
(MIT430)

DESCRIPTION ■ Analogue arc - The display also features an analogue arc


to replicate the response of a moving coil display.
The new Megger MIT400 series insulation and continuity
■ PI and DAR - Polarisation Index (PI) and Dielectric
testers has been designed for electrical testing by the
utilities, industrial, commercial and domestic electricians. Absorption Ratio (DAR) functions
The wide range of features also makes the MIT400 series ■ 200 G1 - Insulation testing from 20 G1 (MIT400) to
ideal for the maintenance and service/repair engineer. 200 G1 (MIT420 and MIT430).
■ Silicone leads - High quality flexible silicone test leads
They replace the well-established BM400 insulation tester
range, given greater functionality with simplified operation, are comfortable to use and prevent measurement errors
greater application range and increased safety. on higher G1 ranges.
■ Test inhibit - prevents testing if voltages in excess of 50 V
The range are detected when making insulation tests.
The range consists of five instruments:
■ Insulation buzzer - The buzzer can be set to buzz if the
MIT400 250 V, 500 V and 1000 V insulation resistance is above a preset limit, set via the
MIT410 50 V, 100 V, 250 V, 500 V and 1000 V + PI, DAR Setup menu.

MIT420 50 V, 100 V, 250 V, 500 V & 1000 V + PI, DAR and CONTINUITY TESTING
result storage
■ Auto-test - Auto test on circuit contact enables real two
MIT430 50 V, 100 V, 250 V, 500 V & 1000 V + Bluetooth handed operation without the need to press the test
download button.
MIT40X 10 V to 100 V in 1 V steps ■ 200mA or 20mA - Either 200 mA or 20 mA continuity
test currents are available. 20 mA test current will
INSULATION TESTING considerably increase battery life.
■ Lead null - Lead resistance compensation (NULL)
■ Test voltages - 250 V to 1000 V or 50 V to 1000 V
operates up to 9 1 of resistance.
insulation test voltages available
■ Buzzer - ON-OFF selected by simple push button.
■ Test Lock - Locks insulation test on continuously.
■ Buzzer limit - Continuity buzzer limit alarm provides
■ Test voltage display - The actual test voltage is displayed
adjustment of the maximum resistance the continuity
on the smaller digital readout, with the insulation result
buzzer sounds. This is adjustable from 1 1 to 20 1 in 5
on the larger digital display.
steps.
MIT400 Series
Industrial Insulation Testers

■ k1 range extends resistance measurement to 1 M1. transmitter being enabled when the Download mode is
selected on the instrument.
DISPLAY NOTE: The receiving PC needs to have Bluetooth capability
or a USB port fitted a Bluetooth receiver. Class II (10m) is
The display offers a combination of analogue arc and a dual acceptable.
digital readout:
Analogue arc: SAFETY
■ Full display width analogue arc. Designed to be exceptionally safe to use, fast detecting
■ Patented arc display shows essential charge and discharge circuitry prevents damage to the instruments if accidentally
characteristics not visible on a digital display. connected to live circuits or across phases. Specifically, all
■ Single pointer “needle” response is similar to a moving instruments:
coil meter. ■ Meet the international requirements of IEC1010-2 and
■ Logarithmic display for better low insulation value EN61557.
measurements. ■ Live circuit detection inhibits insulation testing on circuits
above 50 V.
Dual digital display: ■ Live circuit detection and test inhibit on continuity
■ Large main digital readout for good visibility of all main measurements.
measurement results ■ Default display of live circuit voltage on all ranges.
■ Second digital display for additional data such as: ■ Detection and inhibit functions even if the protection
Insulation test voltage. fuse has failed.
■ Suitable for use on CAT IV applications and supply
Insulation leakage current.
voltages to 600 V.
Supply frequency (when measuring volts).
Test mode eg. PI, DAR or TI (Timed mode). 600 V CAT IV

MIT40X - VARIABLE INSULATION VOLTAGE All MIT400 instruments are designed to meet the safety
TESTER. requirements for use on CAT IV 600 V.

The MIT40X provides a unique solution for awkward


insulation voltage measurement applications. The MIT40X APPLICATIONS
has a variable insulation test voltage from 10 V to 100 V in
(A) Electrical installations testing:
1 V steps, selectable in the “Set-Up” menu. Once selected
this can only be changed by re-configuring in the Setup The MIT400 includes all the features required for
menu. electricians and engineers working in a range of industries.
Available features are selected to make testing easy and fast
Typical applications include: in a range of situations. Typical industries include:
■ Commercial avionics Electrical supply companies
Large and small scale electrical installation
■ Military land, marine and air communications
Periodic inspection and testing
■ Manufacturing/production line goods Cable testing
■ Electrostatic measurement
(B) Service, repair and maintenance:
■ Component testing

The MIT410 and MIT420 add additional features required
Battery powered traction and lifting equipment
for engineers working on more demanding applications.
Functions such as PI and DAR, capacitance measurement
STORAGE & DOWNLOADING RESULTS and higher insulation range increase the suitability for
MIT420 applications such as:
The MIT420 is capable of saving test results for recall to the Manufacturing/production testing
screen. A simple storage structure allows for a test number Panel building
and screen results to be recalled individually. Railway and other transportation
Motor testing
MIT430 Cable inspection/quality control
The MIT430 supports both test result storage and down- Street lighting maintenance
loading. Avionics ground testing and maintenance
Military applications
Test results can be stored in the instrument and subse-
quently downloaded to a computer with the Megger down-
load manager software.
Data transfer is by Bluetooth, with the MIT485 Bluetooth
MIT400 Series
Industrial Insulation Testers

SPECIFICATION Accuracy: ±3% ±2 digits


Open circuit voltage: 5 V ±1 V
All quoted accuracies are at +20°C. Short circuit current: 20 µA ± 5 µA

Insulation Voltage range


Nominal test voltages 0 to 600 V d.c. ±2% ±2 digits
MIT400 250 V, 500 V, 1000 V 10 mV to 600 V TRMS sinusoidal (40 to 400 Hz) ±2% ±2 digits
MIT410, 420,430 50 V, 100 V, 250 V, 500 V, 1000 V 0 to 1000 V on Analogue scale
MIT40X 10 V to 100 V variable (1 V increments) Unspecified input level 0 - 10 mV (40 to 400 Hz)

Insulation resistance range For non-sinusoidal waveforms additional specification


MIT400 20 G1 apply:
MIT410 100 G1 ±3% ±2 digits 101 mV to 600 V TRMS and ±8% ±2 digits 10 mV to
MIT420, 430 200 G1 100 mV TRMS
MIT40X 200 G1
Default Voltmeter: Operates at >25 V a.c. or d.c.
Range Full Scale Accuracy on any range except OFF
1000 volts ±3% ±2 digits ±0.2% per G1
500 volts. ±3% ±2 digits ±0.4% per G1 Frequency: 40-450 Hz (40 Hz - 99,9 Hz)
250 volts. ±3% ±2 digits ±0.8% per G1 ±0.5% ±1 digit (100 Hz to
100 volts. ±3% ±2 digits ±2.0% per G1 450 Hz)
50 volts. ±3% ±2 digits ±4.0% per G1
10 volts ±3% ±2 digits ±2.0% per 100 M1 Capacitance measurement
MIT420, MIT430
Analogue range: 1 G1 full scale
Measurement range: 100 pF to 10 µF
Short Circuit Current: 2 mA +0% -50% Accuracy: ± 5.0% ±2 digits
Terminal voltage: -0% +20% ±1 V

Test Current on load: Distance by capacitance:


1 mA at min. pass value of insulation specified in BS7671, HD384 MIT420, MIT430
and IEC364, 2 mA max. Arithmetic conversion from capacitance measurement on
Default capacitance measurement: 50nF/m
EN61557 Operating range: 0,10 M1 to 1,00 G1
Capacitance range: 40 nF/m to 60 nF/m
Leakage Current: 10% ±3 digits
Result storage
Voltage display: 3% ±3 digits ±0.5% of rated Capacity: >1000 test results
voltage Download: Bluetooth wireless
Bluetooth Class: Class II
Polarisation Index (PI): 10 min / 1minute ratio Range: up to 10 m

Dielectric Absorption Ratio (DAR): 60 sec / 30 sec ratio Power Supply:


5 x 1,5 V cells type IEC LR6 (AA, MN1500, HP7, AM3 R6HP) Alkaline
Notes: NiMH rechargeable cells may be used.
(1) All ranges measure from 0,00 M1 upwards.
Battery life: 2200 insulation tests with duty cycle of 5 sec ON /55
(2) Above specifications only apply when high quality silicone leads
sec OFF @ 1000 V into 1 M1
are being used.
Dimensions
Continuity Instrument: 220 x 92 x 50 mm (8.66 in. x 3.63 in. x 1.97 in.)
Measurement: 0,01 1 to 99,9 1 (0 to 100 1 on
analogue scale) Instrument + case: 456 x 178 x 89 mm (18 in. x 7 in. x 3.5 in.)
Accuracy: ±3% ±2 digits (0 to 100 1)
Open circuit voltage: 5 V ±1 V Weight
Instrument only: 590 gms, 775 gms with boot (20.73 oz.
Test current: 200 mA (–0 mA +20 mA) (27.22 oz.)
(0.01 1 to 9.99 1) Instrument plus case: 1.75kg (3.86 lb)
20mA (±1 mA )
(10.0 1 to 99.9 1) Fuse
Use only a 500 mA (FF) 1000 V 32 x 6 mm ceramic fuse of high
Zero offset at probe tips: 0,10 1 typical breaking capacity HBC 50 kA minimum. Glass fuses MUST NOT be
Lead resistance zeroing: Up to 9,00 1 fitted.
Buzzer: Variable limit 1 1, 2 1, 5 1,
10 1, 20 1
Safety Protection
The instruments meet EN 61010-1 (1995) to 600 V phase to earth,
Resistance Category IV. Refer to safety warnings supplied.
Measurement: 0,01 k1 to 1000 k1 (0 to 1 M1
on analogue scale)
MIT400 CATIV
Industrial Insulation Testers

E.M.C.
In accordance with IEC 61326 including amendment No.1

Temperature effects
Temperature coefficient: <0,1% per °C up to 1 G1

Environmental
Operating range: -10 to +55°C
Operating humidity: 90% RH at 40°C max.
Storage temperature range: -25 to +70°C
Calibration Temperature: +20°C
Maximum altitude: 2000 m
Dust and water protection:
IP54 Protected against dust and splashing water

The Bluetooth word mark and logo are owned by the Bluetooth SIG, Inc. and
any use of such marks by Megger is under license.

ORDERING INFORMATION
Item (Qty) Order No. Item (Qty) Order No.
Basic CATIV 600 V with 250 V/500 V/1000 V insulation 1 x Red croc clip
MIT400-EN 1 x Black croc clip
As MIT400 + 50 V, 100 V, PI and DAR MIT410-EN 1 x instrument rubber boot
As MIT410 + result storage and recall MIT420-EN 1 x Calibration certificate (not included with MIT40X)
Bluetooth downloading version of MIT420 MIT430-EN 1 x Switched probe (not included with MIT400)
Special selectable voltage 10-100 V MIT40X-EN Owners information CD
Included accessories Optional accessories
Test leads: 2 wire lead set to CAT IV 600 V, consisting of : Replacement lead set 6220-813
1 x Red lead 1.25m complete with probe SP5 remote switch probe 6220-812
1 x Black lead 1.25m complete with probe Rubber boot with stand 6231-802
Hard case 5410-420
Item 1E
MIT520/2 and MIT1020/2
5 kV and 10 kV Insulation Resistance Testers

MIT520/2 and MIT1020/2


5 kV and 10 kV Insulation Resistance
Testers
I CAT IV 600 V
I Mains or battery powered
I Variable test voltage from 50 to 5000 or
10,000 V
I Automatic IR, PI, DAR, SV and DD tests
I Measures to 15 T Ω (5 kV) and 35 TΩ
(10 kV)
I RS232 and USB download of results to
Megger Download Manager
I On board memory for results storage

DESCRIPTION

The new 5 and 10 kV insulation resistance testers from The instrument is fitted with a guard terminal to enhance
Megger are designed specifically to assist you with the accuracy. The guard test lead is included as standard with
testing and maintenance of high voltage electrical the instrument.
equipment. IEEE 43-2000 recommends the use of 10 kV for
motor windings rated above 12 kV and the Megger To further enhance the flexibility of the instruments both
MIT1020/2 facilitates this. The case is incredibly rugged and have the facility to set the test voltage in steps from 50 V to
easy to carry, being made of tough polypropylene and the maximum output voltage avoiding the expense of
achieving an ingress protection rating of IP65. In addition, several insulation resistance testers to meet your application
the model number is marked on both sides of the case for needs.
ease of identification in stores or vehicles.
These IR instruments are designed to meet the highest
The instruments have a large easy to read backlit LCD safety standards and meet the requirements of EN61010. In
display making it equally suitable for use in both bright addition, the instrument measures the voltage at the
sunlight and poorly lit environments. Information displayed terminals and if this is above 50 V then the instrument will
includes resistance, voltage, leakage current, capacitance, display the high voltage warning and inhibit testing. At the
battery status and time constant. In addition, the elapsed end of the test the instrument will automatically discharge
time of the test is displayed constantly, removing the need the energy transferred to the equipment during the test
for separate timers. Adjustable timers and limit alarms are phase.
included.
The MIT520/2 and MIT1020/2 are equally suited to routine
The instrument can test when being powered by the mains testing and diagnostic regimes being pre-programmed with
or its internal rechargeable battery, a great benefit when site IR, PI, DAR, SV and DD profiles.
conditions are unknown or long term testing is required.

The controls of the instrument are clear and unambiguous


and a "quick start" guide is included in the lid of the
instrument removing the need to carry bulky manuals
under site conditions.
MIT520/2 and MIT1020/2
5 kV and 10 kV Insulation Resistance Testers

SPECIFICATION Real time output


Voltage input range Serial, once per second of test voltage, current and resistance
85-265 V rms, 50/60Hz, 60 VA Operating temperature
-20°C to 50°C

MIT520/2 battery life
Typical capacity is 6 hours continuous testing at 5 kV with a 100 M Storage temperature
load -25°C to 65°C
MIT1020/2 battery life Ingress protection (lid closed)


Typical capacity is 4 hours continuous testing at 10 kV with a 100 IP65
M load
Humidity
MIT520/2 test voltages 90% RH non-condensing at 40°C
50 V to 1 kV in 10 V steps, 1 kV to 5 kV in 25 V steps
Safety
MIT1020/2 test voltages Meets the requirements of EN61010-1:2001 CATIV 600 V
50 V to 1 kV in 10 V steps, 1 kV to 10 kV in 25 V steps
EMC


MIT520/2 accuracy (23°C, 5 kV) Meets the requirements of EN61326-1:2006 for use in heavy


±5% to 1 T industrial areas.
±20% to 10 T
Dimensions


MIT1020/2 accuracy (23ºC, 10 kV) 305 x 194 x 360 mm (12.7 x 6 x 14.2 inches)


±5% to 2 T
±20% to 20 T Weight
7.1 kg (16lb) approx.

Ω leakage with 100 MΩ load


Guard
2% error guarding 500 k

Digital display (3 digits) 10 kΩ to 15 TΩ (MIT520/2)


Display range

to 35 TΩ (MIT1020/2)
Analogue display 100 kΩ to 1 TΩ
Short circuit/charge current
3 mA @ 5 kV (MIT520/2) or 10 kV (MIT1020/2)
Capacitor charge time
<3 seconds per µF at 3mA to 5 kV (MIT520/2)
<5 seconds per µF at 3mA to 10 kV (MIT1020/2)

Capacitor discharge time


<120ms per µF to discharge from 5000 V to 50 V (MIT520/2)
<250ms per µF to discharge from 10000 V to 50 V (MIT1020/2)
Capacitance measurement (above 500 V)
10 nF to 50 µF (dependent on measurement voltage)
Capacitance measurement accuracy (23°C)
±5% ±5 nF

Ω load
Voltage output accuracy (0°C to 30°C)
+4%, -0%, ±10 V of nominal test voltage at 1 G

Current measurement range


0.01 nA to 5 mA
Current measurement accuracy (23°C)
±5% ±0.2 nA at all voltages
Interference rejection
MIT520/2 1 mA per 250 V up to a maximum of 2 mA
MIT1020/2 1 mA per 600 V up a maximum of 2 mA
Timer range
Up to 99 minutes and 59 seconds from start of test
15 second minimum setting for test voltage ≥1000 V
30 second minimum setting for test voltage <1000 V

Memory capacity
32kB
Test regimes
Auto IR, PI, DAR, SV and DD.
Interface
RS232 and USB
Data store
Voltage, test time, leakage current, resistance, PI, DAR, DD,
capacitance and time constant
MIT520/2 and MIT1020/2
5 kV and 10 kV Insulation Resistance Testers

ORDERING INFORMATION
Item (Qty) Order Code Item (Qty) Order Code
5 kV insulation resistance tester MIT520/2 Control circuit test lead sets
10 kV insulation resistance tester MIT1020/2 2 x 3 m control circuit, small insulated clips 6220-822
Included Accessories
3 m lead set insulated clips 6220-820 Screened HV test leads
User guide on CD-ROM 2000-213 1 x 3 m, 5 kV screended un-insulated
RS232 cable 25955-025 small clips 6220-835
USB cable 25970-041 1 x 15 m, 5 kV screened un-insulated
small clips 6311-080
3 x 3 m lead set insulated clips (MIT1020/2 only) 6220-811
1 x 3 m, 10 kV screended un-insulated
small clips 6220-834
Optional Accessories
1 x 10 m, 10 kV screened un-insulated
HV test lead sets
small clips 6220-861
3 x 3 m un-insulated small clips 8101-181
1 x 15 m, 10 kV screened un-insulated
3 x 8 m un-insulated small clips 8101-182 small clips 6220-833
3 x 15 un-insulated small clips 8101-183
3 x 10 m medium insulated clips 1000-441
3 x 15 m medium insulated clips 1000-442
3 x 3 m large insulated clips 6220-811
3 x 10 m large insulated clips 1000-443
3 x 15 m large insulated clips 1000-432

Registered to ISO 9001:2000 Cert. no. Q 09250

Registered to ISO 14001-1996 Cert. no. EMS 61597


2.Winding Resistance
Testing
Item 2A
MTO210
Transformer Ohmmeter

MTO210
Transformer Ohmmeter

■ Direct 2-channel digital reading


■ Patented “Quick Test” measurement technique
■ 0.25% measurement accuracy
■ Integrated demagnetization feature
■ Tests operation of on-load tap-changers
■ Auto safety discharge circuit provided

DESCRIPTION ■ To help locate the presence of defects in transformers,


The MTO210 Transformer Ohmmeter is a line-operated, such as loose connections
field-portable instrument designed specifically to measure ■ To check the “make-before-break” operation of on-load
the dc resistance of all types of magnetic windings safely
tap-changers
and accurately. It can test rotating machine windings and
perform low-current resistance measurements on A regular maintenance program that includes winding
connections, contacts and control circuits. resistance measurements is the most effective way to use
this instrument. Once a benchmark is established,
The MTO210 employs a patented “Quick Test”
subsequent test results can be compared to determine if
measurement technique, which stabilizes the measurement
changes are occurring in the transformers and associated
current in the shortest time possible in order to
control wiring, voltage regulators, motors, generators,
significantly reduce test times.
breaker contacts, and all types of connections (bolted,
Also, the dual set of potential inputs measures the soldered, crimped, etc.).
resistance of the primary and secondary windings of a
Tap-changers are mechanical devices and the most
single- or three-phase transformer simultaneously. This
vulnerable part of a transformer. Tap-changers result in
dual reading characteristic, along with the bi-directional
more failures and outages than any other component and
current output capability, also help to speed up the
so require frequent testing and attention to ensure proper,
measurements when used to test windings on three-phase
reliable operation.
transformers.
The Transformer Ohmmeter is extremely useful when
FEATURES AND BENEFITS
testing the windings and contact resistance of tap-changers ■ Direct 2-channel digital reading allows for testing two-
with “make-before-break” contacts and voltage regulators.
windings at a time without the need for time-consuming
This action will check for pitted or misaligned contacts as
bridge balancing.
the instrument will give an indication if either condition
occurs. ■ Patented “Quick Test” measurement technique minimizes
test time.
Users are protected by the auto-shutdown safety feature.
Any inadvertent disconnection of a test lead or loss of ■ User-selectable maximum current range ensures
power to the instrument will safely discharge the energy protection of small transformers.
stored in the test sample.
■ Bi-directional current output capability allows the unit to
take advantage of any existing magnetization of the
APPLICATIONS transformer core to help stabilize test currents quicker in
The MTO210 Transformer Ohmmeter is used: order to reduce test times.
■ To verify factory test readings ■ Built-in demagnetization circuitry allows the operator to
de-magnetize the transformer core, either before or
■ As part of a regular maintenance program
upon completion of resistance testing, or as a stand-
alone feature.
MTO210
Transformer Ohmmeter

■ The MTO210 allows for test of transformers with on- SPECIFICATIONS


load tap-changers and provides a “break-before-make”
indicator, in the event of any discontinuity. Input
120/240 V, 50/60 Hz, 720 VA
■ Beacon drive circuit is provided for use with optional
beacon strobe light. Output
Current Range: Up to 10 A (dc)
■ For those users who choose to create an external Open-Circuit Test Voltage: up to 50 V dc
interlock safety fence, a safety interlock circuit is
Resistance measurement/display
provided.
Resistance: 1 µΩ to 2000 Ω
■ Remote trigger switch is provided for testing Accuracy: ±0.25% reading, ±0.25% full scale (when current has
transformers with tap-changers. stabilized)
Resolution: Up to 6 digits
■ Internal flash memory allows for mass storage of dataset
Environmental
records, for later recall, printing, and analysis.
Operating: 14° F to 122° F (-10° C to 50° C)
■ Ruggedized Kelvin clamps, with 4 inch (100 mm) jaws, Storage: 5° F to 158° F (-15° C to +70° C)
are provided eliminating the need for bushing adapters. Relative Humidity: 0-90% non-condensing

■ Field upgradeable firmware. Displays


Two 1” high, 6 character, 7-segment, LCDs
■ Compatible with PowerDB software package. One 0.71” high, 6 character, 7-segment, LCD
■ Built-in discharge circuit safely discharges the specimen Dimensions
when test is completed, if lead accidentally disconnects 8.5 H x 21.5 W x 13 D in (216 H x 546 W x 330 D mm)
or if power is lost. Weight
■ Wide resistance range allows heat-run testing of many Net 28 lb (12.7 kg)
transformer types. Printer
Print to optional 4 inch strip thermal paper printer
■ Output RS232 serial port is provided for optional
printing of results.
■ Ideal for use in shop or substation environments
because of its light weight and portability.

ORDERING INFORMATION
Item (Qty) Cat. No. Item (Qty) Cat. No.
Transformer Ohmmeter Optional Accessories
120/240 volt, 50/60 Hz input MTO210
Potential leads, 66 ft (20m) [2pr] 37179
Included Accessories Current leads, 66 ft (20 m) [2 pr] 37180
Potential leads, 33 ft (10 m) [2 pr] 37173 Beacon strobe light 37181
Current leads, 33 ft (10 m) [1 pr] 37174 Printer (includes battery/line powered serial
Shorting lead, 9.9 ft (3 m) [1] 37175 thermal printer, printer interface cable)
Ground lead, 15 ft (4.6 m) [1] 4702-7 120 V, 60 Hz 35312-1
AC power cord (IEC60320-C13 to US standard) 17032 230 V, 50 Hz 35312-2
AC power cord (IEC60320-C13 to Schuko CEE 7/7) 17032-13 Foam-lined transit case 37182
Interlock connector 37177 Remote trigger switch 30915-220
In-lid quick start guide 37178 PowerDB (full version) software DB1007
Canvas carrying bag (for leadset) 30915-211
Instruction manual ATVMMTO210
PowerDB LITE software DB0001

Registered to ISO 9001:2000 Cert. no. 10006.01


Item 2B
DLRO 10 AND DLRO10X
Digital Microhmmeter

DLRO 10 and DLRO 10X


Digital Microhmmeter

■ Auto current reversal cancels standing


emfs
■ Protected to 600 V
■ Automatically detects continuity in
potential and current connections
■ Multiple operating modes including fully
automatic
■ Alpha-numeric keypad for entering test
notes (DLRO 10X)
■ User selectable high and low limits
(DLRO 10X)
■ Printer output and memory (DLRO 10X)

DESCRIPTION To assist operator safety and ease of use, both instruments are
supplied complete with a pair of duplex handspikes with 1.2 m
DLRO 10 and DLRO 10X set the standards for low resistance (4 ft) leads. One of the probes is fitted with LED’s, which
measurement. DLRO 10 and DLRO 10X are fully automatic duplicate indicators on the instrument display indicating that all
instruments, selecting the most suitable test current up to 10A d.c. four contacts have been made, the presence of a high voltage
to measure resistance from 0.1 µΩ to 2000 Ω, on one of seven across the load, and the presence of current flow while a load is
ranges. discharging. A full range of test leads is available with probes,
For users who desire more control over the measurement process, clamps and Kelvin clips.
DLRO 10X uses a menu system controlled by a two-axis paddle to Nickel Metal Hydride (NiMH) batteries power the instruments.
allow the user to manually select the maximum test current. The battery packs are interchange-able so that an exhausted
DLRO 10X also adds real time download of results and on board battery may be recharged using the external charger supplied
storage for later download to a PC. while testing continues using a spare pack. Although full charging
will take 4 hours, a fast charge mode allows the battery to be 90%
Both instruments are built into a strong, lightweight case that is charged within 2 1/2 hours from a 12 volt battery or from a
equally at home in the field or in the laboratory. Light enough to standard 120/230 V AC supply via the supplied charger. The
be worn around the neck, they are small enough to be taken into battery pack contains its own battery state indicator, which allows
areas that were previously too small to access. the charge-state to be monitored, even without being connected
DLRO 10 uses a large, bright 4 1/2 -digit LED display while DLRO to the instrument.
10X has a large, backlit LCD display. Normally, measurements are DLRO 10X is fitted with RS232 communications that will allow
made with forward and reverse currents to cancel the effects of results to be downloaded in real time or stored for later retrieval.
any standing voltages across the test sample.
Up to 700 sets of results may be stored within DLRO 10X
The average value is then displayed within 3 seconds, to a basic complete with notes containing up to 200 characters which may
accuracy of 0.2%. DLRO 10X displays both forward and reverse be added using the on board keypad. These results can also be
measurements as well as the average of the two. downloaded to a PC.
DLRO 10X allows the user to set high and low pass limits, thereby MEASUREMENT MODES:
enabling simple go-no-go testing. A variety of measurement modes are available. Since the
At the end of a test DLRO10X will store the test results, as well as introduction of V2.0 firmware, Normal, Auto, Continuous and
any notes relevant to the test. Inductive mode are available on both the DLRO 10 and the
DLRO 10X.
DLRO 10 AND DLRO 10X
Digital Microhmmeter

DLRO 10 will display the average of the measurements achieved FEATURES AND BENEFITS
using forward and reverse current, while DLRO 10X displays both
individual measurements and the average. ■ Small, lightweight and portable - can be used in tight places,
reduces the need for extra long leads and two person
Normal mode initiates a test by pressing the Test button on the operation.
instrument front panel after connecting the test leads. Continuity
■ Four terminal resistance method shows the true resistance of
of all four connections is checked, forward and reverse currents
the item under test.
are applied.
■ Bright LED (DLRO 10) and LCD (DLRO 10X) displays are easily
Auto mode allows forward and reverse current measurements to visible under all lighting conditions and reduce human error.
be made and the average displayed simply by making contact
■ Automatically applies forward and reverse currents which cancel
with all four probes. This mode is ideal when working with the
out any standing voltages across the sample under test.
supplied handspikes. Each time the probes are removed and
reconnected to the load another test will be performed without ■ Checks for undue noise during measurement, reducing the
the need to press the test button on the instrument. possibility of recording the incorrect result.
■ Automatically detects continuity in P and C circuits, preventing
Continuous mode allows repeated measurements to be made on
erroneously high reading to be taken due to high resistance
the same sample. Simply connect the test leads and press the test
contact.
button. The measurement is updated every 3 seconds until the
circuit is broken. ■ Battery module has a battery condition indicator allowing the
user to check the state of spare batteries without connecting to
Inductive mode is intended for use when measuring inductive the instrument.
loads. When measuring inductive loads it is necessary to wait for
■ RS232 connector on the DLRO 10X allows downloading of
the voltage to stabilise. This means that the measurement could
results in real time or stored for later retrieval.
take a few seconds or several minutes. The test leads are firmly
connected to the item to be measured and the Test button is
pressed. The instrument will pass a current through the sample
and wait for the voltage to stabilise. If possible the current will be
increased. This procedure will be repeated until the voltage
detected falls into the range 15 mV to 200 mV. The instrument will
then continue to take readings, which will gradually decrease to
the true value as the voltage stabilises further. The operator
decides when the result is stable and presses the Test button to
terminate the test. Measurement is made with forward current only.

Unidirectional mode, on DLRO 10X only, applies a current in


one direction only. This does not enable any standing emfs to be
negated but speeds up the measurement process. Test starts
automatically when probes are connected.

APPLICATIONS
The needs for accurate low resistance measurement are well
known and very diverse. They range through Goods Receiving
inspection of components to ground bonding and welded joints.
Typical applications include, but are not limited to, making d.c.
resistance measurements of:

■ Switch and contact breaker resistance


■ Busbar and cable joints
■ Aircraft frame bonds and static control circuits
■ Integrity of welded joints
■ Inter-cell connections on battery systems up to 600 V peak
■ Quality control of resistive components
■ Transformer and motor winding resistance
■ Rail and pipe bonds
■ Metal alloys, welds and fuse resistance
■ Graphite electrodes and other composites The DLROs are light enough to be worn around the neck. They
are also small enough to be taken into areas which were
■ Wire and cable resistance previously too cramped for easy testing.
■ Transmitter aerial and lightning conductor bonding
DLRO 10 AND DLRO 10X
Digital Microhmmeter

Full Scale Volts Test Current


Full Scale Resolution Accuracy Resistive Inductive Resistive Inductive

1.9999 mΩ 0.1 µΩ ±0.2% ±0.2µΩ 20 mV n/a 10 A n/a


19.999 mΩ 1 µΩ ±0.2% ±2 µΩ 20 mV 20 mV 1A 1A
199.99 mΩ 10 µΩ ±0.2% ±20 µΩ 20 mV 200 mV 100 mA 1A
1.9999 Ω 100 µΩ ±0.2% ±0.2 mΩ 20 mV 200 mV 10 mA 100 mA
19.999 Ω 1 mΩ ±0.2% ±2 mΩ 20 mV 200 mV 1 mA 10 mA
199.99 Ω 10 mΩ ±0.2% ±20 mΩ 20 mV 200 mV 100 µA 1 mA
1999.9 Ω 100 mΩ ±0.2% ±0.2 Ω 200 mV 200 mV 100 µA 100 µA

DLRO 10 DLRO 10X


Measurement: Mode: Manual, Auto, Continuous, Manual, Auto, Continuous,
High Power High Power, Unidirectional
Control: Fully Automatic Fully Automatic/Manual
Speed: <3s for forward & reverse current and to display average
Display: Measurement: 41/2 digit seven segment LED
Range and Safety: LED indication Large backlit LCD
Test Method: Single cycle reversing d.c. ratiometric measurement -average result display.
Test Current: Accuracy: ±10%
Stability: <10 ppm per second
Maximum Lead Resistance: 100 mΩ total for 10A operation irrespective of battery condition.
Voltmeter input impedance: > 200 kΩ
Hum rejection: Less than 1% ±20 digits additional error with 100 mV peak 50/60 Hz. on the potential leads. Warning
will show if hum or noise exceeds this level.

Data: Transfer: Real Time or from storage via RS232


Storage: 700 tests
Memo Field Up to 256 characters per test via integral
alphanumeric keypad
Battery: Capacity: 7 Ah NiMH rechargeable
Life: Typically 1000 x 10 A tests before recharge
Recharge: Via External 90V - 260V 50/60 Hz charger or from 12 to 15V d.c. supply
Charging Rate: Standard: 2.5 hours to 90% capacity, 4 hrs for full charge
Temperature: Operation: +5ºC to +45ºC (41ºF to 113ºF) at full specification
Storage: -10ºC to +50ºC (14ºF to 122ºF) at reduced accuracy
Calibration: -30ºC to +70ºC (-22ºF to 158ºF)20ºC (68ºF)
Co-efficient: <0.01% per ºC over range 5ºC to 40ºC
Slow charging: <0.01% per ºC from 5ºC to 40ºC (<0.006% per oF from 41ºF to 104ºF)
Fast charging: 0ºC to +45ºC (32ºF to 113ºF)
Humidity (max): +10ºC to +45ºC (50ºF to 113ºF)
Altitude (max): 90% RH @ 40ºC (104ºF) non-condensing
Safety: 2000m (6500 ft) to full safety specifications
EMC: In accordance with EN61010-1 600V Category III
The instrument meets EN50081-1 and EN50082-1 (1992)
Dimensions: 220 x 100 x 237 mm (8.6 x 4 x 9.5 in)
Weight: 2.6 kg (5 3/4 lb.) including battery module.
DLRO 10 AND DLRO 10X
Digital Microhmmeter

ORDERING INFORMATION
Item (Qty) Order No. Item (Qty) Order No.
DLRO 10 Digital Low Resistance Ohmmeter 6111-428 Straight Duplex Handspikes (2)
DLRO10X Digital Low Resistance Ohmmeter 6111-429 Heavy Duty with fixed contacts. 2m/7ft 242002-7
Complete with 5.5m/18ft 242002-18
7 Ah NiMH battery module. 6340-101 9m/30ft 242002-30
DH4 Duplex handspikes (2), Duplex Heavy Duty 5cm (2")
one with indicator lights. 1.2m / 4 ft 6111-503 C-Clamps. (2) 2m/7ft 242004-7
Battery charger for operation from 115/230 V . 5.5m/18ft 242004-18
50/60Hz supply. 6280-333 9m/30ft 242004-30
Cigar lighter adapter for battery charging. 6280-332 Duplex handspikes with replaceable
User guide. 6172-473 Needle Points 2m/7ft 242003-7
Warranty book. 6170-618 Duplex 1.27 cm (1/2 ")
Optional Accessories at extra cost Kelvin Clips. (2) gold plated 2m/7ft 241005-7
Carrying case for DLRO10/10X silver plated 2m/7ft 242005-7
and all standard accessories. 6380-138 Duplex 3.8 cm (11/2")
Carrying case for optional lead sets. 18313 Kelvin Clips. (2) 2m/7ft 242006-7
Calibration Shunt,10 Ω, current rating 1 mA. 249000 5.5m/18ft 242006-18
Calibration Shunt, 1 Ω, current rating 10 mA. 249001 9m/30ft 242006-30
Calibration Shunt, 100 mΩ current rating 1A. 249002 Single Leads
Calibration Shunt, 10 mΩ current rating 10 A. 249003 Single handspike (1) for
Certificate of Calibration for Shunts, NIST CERT-NIST potential measurement. 2m/7ft 242021-7
Replacement tips for DH4, DH5 and DH6 handspikes. 5.5m/18ft 242021-18
Needle point 25940-012 9m/30ft 242021-30
Serrated end 25940-014 Current clip (1) for current
Optional Test Leads at extra cost connections. 2m/7ft 242041-7
Duplex Leads 5.5m/18ft 242041-18
DH5 straight duplex handspikes (2). 9m/30ft 242041-30
One has indicator lights. 2.5m/8ft 6111-517
DH6 Duplex handspikes (2) suitable
for working on 600 V. systems. 2.5m/8ft 6111-518
Duplex Handspikes (2) with spring
loaded helical contacts. 2m/7ft 242011-7
2.5m/8ft 6111-022
5.5m/18ft 242011-18
6m/20ft 6111-023
9m/30ft 242011-30
Item 2C
R8228-5 - IMPULSE WINDING TESTER
Function:
Verification of the quality on electrical windings with control of
the absence of short-circuits

Application:
On any kind of winding with a minimum of 10 microHenry
inductance

Use:
Laboratory or small productions

Features:
x Low energy test without damaging the coil
x 4 kind of waveform comparison methodes
x Up to 20 MSPS sampling rate
x Multi-trigger mode programmable
x Direct display of comparison results

Technical specifications
x Output impulse voltage : 500-5000V +/-3% +/-5V
Voltage control mode
x Normal : Voltage programmable on terminals when terminals
are open
x Contant : mantains voltage selected across the winding
indipendent of changes of the winding impedance
x Sampling rate : 20MSPS/50nsec - 10MSPS/100nsec
x Sampling rate : 5MSPS/200nsec - 2.5MSPS/400nsec
x Sampling rate : 1.25MSPS/800nsec - 625kSPS/1600nsec
x Sampling rate : 312kSPS/3200nsec - 156kSPS/6400nsec
x Resolution : 8 bits
x Sampling points : 960 bytes
x Input impedance : 10Mohm (resistive voltage divider)
x Waveform measurement : Voltage, time, frequency
x Area size comparison
x Differential area comparison
x Corona discharge
x Differential phase comparison
x Area size repetition accuracy : +/- 1%
x Differential area repetition accuracy : +/- 1%
x Detection output : PASS/FAIL display, Alarm
x 60 groups of standard waveforms can be stored in internal
non-volatile memory
x 800 groups in the USB flash memory (optional)
x Interfaces: RS232-C, Handler, IEEE488, Scanner
3.Transformer Turn Ratio
Testing
Item 3A
TTR®300 Series
Three-Phase Transformer Turns Ratio Test Sets

TTR®300 Series
3-Phase Transformer Turns Ratio Test Sets

■ Stand-alone or remote-control operation


■ Accurately measures ratio, phase deviation
and exciting current
■ Field upgradeable without compromise to
calibration
■ Built-in capability for storing and downloading
test results in an XML format, via RS-232,
Ethernet or USB ports (depending on model)
■ Works in the presence of high interference/
high voltage
■ Highest ratio measurement (45,000:1);
TTR330 shown highest accuracy (0.1%)
■ Displays % error vs. name plate with pass/fail
limits

DESCRIPTION The Series consists of four instruments:


The TTR300 Series of three-phase transformer turns ratio
test sets are designed to measure the turns ratio of power, TTR300
instrument, and distribution transformers in a substation or The TTR300 is designed to be completely remote
manufacturing environment. A rugged and robust design controlled via a PC running PowerDB LITE (included) or
makes these instruments well suited for use in a variety of PowerDB (full version) PC software applications. The
harsh environments. Our leads are specially designed to TTR300 is field upgradeable to the TTR310, TTR320 or
provide the necessary flexibility needed in cold weather. TTR330.

The TTR300 Series are ideal for use by power transformer Some of the features of the TTR300 are:
manufacturers. Their unique testing procedures and ■ Field upgradeable to a model TTR310, TTR320 or
storage capability allows an operator to set up and test TTR330 without compromise to calibration
difficult three-phase transformers (with multiple tap
changers and bushing CTs) in a fraction of the time than it ■ Built-in capability for storing test results into internal
used to take with other TTRs. This test also includes a memory in an open XML data format via PowerDB LITE
pass/fail limit of individual ratios. ■ Quickly download test results via RS-232 serial port
The TTR300 Series also measure the phase deviation of the
transformer primary versus secondary. This quickly
indicates problems in the transformer such as partial
shorted turns and core faults. This measurement is also
useful in verifying phase errors in all types of PTs and CTs.
Each unit comes equipped with a remote-control switch
for single person testing. This allows the operator to test
transformers with LTCs very quickly.

TTR300 — remote controlled “black box” unit


TTR®300 Series
Three-Phase Transformer Turns Ratio Test Sets

Also, with a simple interface to PowerDB LITE PC software


application (included), the user can perform data analysis
and trending of results.
The TTR320 includes the following features:
■ Fully automatic operation (stand-alone or remote-
control)
■ Field upgradeable to a model TTR330 without
compromise to calibration
■ Graphical User Interface allows for automated setup and
control through easy-to-read ICON based screens
TTR310 — text-based LCD interface unit
■ Built-in capability for storing test results, in an open
TTR310 XML format, to either internal memory or to an external
This unit features an easy-to-read, high-contrast LCD USB storage device
which can be seen in bright sunlight and provides the
user interface for instrument set-up and test operation. ■ Built-in RS-232 port and optional thermal spool-paper
The unit comes complete with the software application, printer allows for printing of test results, while in the
PowerDB LITE. field, and without the use of an external computer

The TTR310 has the ability to store test results, upload ■ 5.7” VGA bright color display
results to a PC (via RS232 serial port), and/or print them
in the field via optional thermal paper printer, without the
use of an external computer.
Some of the features of the TTR310 consist of:
■ Fully automatic operation (either stand-alone or
remote-control)
■ Field upgradeable to a TTR330 or TTR320 without
compromise to calibration
■ Built-in RS-232 port and optional thermal spool-paper
printer allows for printing of test results, while in the
field, and without the use of an external computer
■ Built-in capability for storing test results into internal
memory in an open data format for direct input into
Excel® or XML format via PowerDB LITE

TTR320
The TTR320 features a high contrast bright 5.7” full VGA
color display can be seen in direct sunlight. The TTR330 shown testing a pad mount three-phase transformer
instrument employs a full QWERTY keyboard for entering
nameplate-type information. Communications ports are
provided in the form of RS-232, USB and Ethernet ports for TTR330
easy on-board printing, storage, and downloading of test The TTR330 offers a new user interface which allows the
results. operator to interact with the PowerDB ONBOARD
software system via full QWERTY and navigation keypads
as displayed on an 8.4” VGA bright-color screen. One of
the primary benefits of this interface is that it displays the
actual test form on the screen. An advanced feature of the
TTR330 allows the user to customize these test forms via
optional full-version PowerDB.
Other primary features of the TTR330 include three
communications ports (two USB, one Ethernet). The USB
“host” ports can be used for connecting directly to an
optional printer (to print full size 8.5” x 11” completed test
forms) and for data storage to a USB memory device (for
later printing, analysis, archiving, and/or trending). The
Ethernet port allows the TTR330 to interface (on a bi-
directional basis) directly to a PC.
TTR320 — graphical ICON based user interface unit
TTR®300 Series
Three-Phase Transformer Turns Ratio Test Sets

The TTR330 offers the following: PowerDB™ ONBOARD Acceptance & Maintenance
Test Data Management Software (Model TTR330
■ Fully automatic operation (stand-alone or remote-
only)
control) with user interface via on-screen customizable
The “PowerDB ONBOARD” logo means PowerDB
test forms
software is running on a computer embedded within the
■ Integrated PowerDB ONBOARD allows for data analysis TTR330. This powerful feature provides the TTR330 with
and trending while in the field without the use of an a common “User Interface” to minimize operator training
external computer and provides a seamless interface to the full PowerDB
■ Built-in USB port and optional USB printer allows for (PC version) application.
8.5”x 11” test forms printing without the use of a laptop Easy-to-read on-screen test forms provide the user
■ Built-in capability for storing test results, in an open interface for instrument set-up and test operation. Results
XML format, to either internal memory or to an external are displayed against pass/fail nameplate limits and can be
USB storage device stored (either internally or to a USB storage device) in an
open XML data format.
■ Full 8.4” VGA color display
The ONBOARD software also maintains a historical data
PowerDB LITE™ Acceptance & Maintenance
file so that, while in the field, current and past results can
Test Data Management Software
be analyzed, compared, and displayed in trend charts
All four units in the TTR300 Series come complete, at no without the need of an external computer. An 8.5” x 11”
extra charge, with PowerDB LITE (a new powerful PC test form can also be printed in the field via an optional
Windows® based software program). PowerDB LITE allows USB printer, and without the use of an external computer.
the operator to completely program a test routine, in
advance, for a transformer, save it under the transformer Built-in Memory
ID number, and then recall it in the future as required. The TTRs come equipped with sufficient internal memory
to store test results. The outcome of the results are based
Testing on the TTRs can be performed in a remote control
on the model:
manner, via PowerDB LITE. Once testing is complete on
all of the instruments, results are easily downloaded to the TTR310: stores up to 200 three-phase data sets in the field
external PC in an “open” XML data format. The for later retrieval. Test results can be printed on an
instruments’ internal memory also maintains historical data- optional printer (using thermal spool paper) whenever a
files so that, through interface to PowerDB LITE, current hard copy is desired, or the data can be downloaded to a
and past results can be archived, compared, analyzed, PC for archiving, analysis, trending, and/or printing. The
displayed in trend charts, and compiled into Test Reports. system software allows entry of the transformer
alphanumeric serial number, transformer type and tap
Control of the TTRs in this remote-control manner offers
information for each test performed.
the following benefits:

TTR320: stores up to 100,000 data sets in the field for
Easy to use interface between operator and instrument.
later retrieval. Test results can be printed on an optional
■ Problems such as PASS/FAIL are flagged visually using a printer (using thermal spool paper) whenever a hard copy
RED highlight. is desired, or the data can later be downloaded to a PC for

archiving, analysis, trending, and/or printing. Identification
Easily recall transformer setups from a custom settings
of individual test readings is also easily done. The system
menu.
software allows entry of the transformer alphanumeric
■ Quickly download results to the PC for completing a serial number, transformer type and tap information for
transformer test report. each test performed.
PowerDB™ (full version) Acceptance & TTR330: stores up to 100,000 data sets in the field for
Maintenance Test Data Management Software later retrieval. Test results can be printed on an optional
As an enhancement over the PowerDB LITE software in-lid printer (using 8.5” x 11” thermal paper) whenever a
(described above), a powerful “full version” PowerDB hard copy is desired, or the data can later be downloaded
software is also available on the TTR300 Series as an to a PC for archiving, analysis and/or printing.
option. PowerDB LITE and the internal architecture of the Identification of individual test readings is also easily done.
TTR Series has a seamless interface to the full version The system software allows entry of the transformer
PowerDB, PC based software application. alphanumeric serial number, transformer type and tap
information for each test performed.
Multiple data files (from multiple instruments) can
automatically be fed to PowerDB in order to generate
comprehensive asset analysis in the form of Reports
containing table of contents, test data sheets, commentary,
and deficiency summaries.
Electrical utilities who have invested in sophisticated
Computerized Maintenance Management Systems (CMMS)
can easily link with the PowerDB software because it
works with a number of systems.
TTR®300 Series
Three-Phase Transformer Turns Ratio Test Sets

APPLICATIONS Turns Ratio Range and Accuracy


The TTR300 Series applies voltage to the high-voltage 8 V ac: ±0.1% (0.8 to 2000)
winding of a transformer and accurately measures the ±0.25% (2001 to 4000)
resulting voltage from the low voltage winding. In addition ±0.35% (4001 to 8000)
to turns ratio, the units measure excitation current, phase 40 V ac: ±0.1% (0.8 to 2000)
±0.15% (2001 to 4000)
angle deviation between the high- and low-voltage
±0.3% (4001 to 10,000)
windings and percent ratio error. ±0.35% (10,001 to 25,000)
Transformer Turns Ratio 80 V ac: ±0.1% (0.8 to 2000)
±0.15% (2001 to 4000)
Transformer turns ratio is the ratio of the number of turns ±0.25% (4001 to 10,000)
in the high-voltage winding to that in the low-voltage ±0.30% (10,001 to 45,000)
winding. Complexity in the measured ratio versus Resolution: 5 digit for all ratios
nameplate ratio occurs with most three-phase power
Printer Interface
transformers because multipliers such as √3 are required to
TTR300: Not applicable
match the measured ratio to the nameplate ratio. The TTR310: RS-232 port
TTR300 Series automatically applies the multiplier in a TTR320: RS-232 port
form which allows the operator a direct comparison to the TTR330: USB
nameplate (or expected) ratio. The built-in calculator
Computer Interface
displays the % error versus nameplate for each tap and
TTR300 and TTR310: RS-232 port
each winding, without the need for a computer.
TTR320 and TTR330: Ethernet
Exciting Current User Interface
The TTR provides accurate measurement of exciting TTR300: Not applicable
current (to 0.1 mA) which can help provide information TTR310: 5.7 in., B&W display, text on-screen view,
about the condition of a transformer’s core. Unwanted numeric keypad
circulating currents or unintentional core grounds can TTR320: 5.7 in., full-color VGA, graphical icon on-screen view,
increase the exciting current and indicate a problem. full QWERTY keypad and navigational pushbuttons
TTR330: 8.4 in., full-color VGA, test forms on-screen view,
Phase Angle Deviation and its Application full QWERTY keypad and navigational pushbuttons
The phase angle deviation, displayed in either degrees Internal Data Storage
(minutes) or radians, is the phase relationship between the TTR310: up to 200 data sets
voltage signal applied to the high-voltage winding and the TTR320 and TTR330: up to 100,000 data sets
voltage signal extracted from the low-voltage winding. The Communication/Control Software
phase deviation, together with ratio error, can be used as a PowerDB LITE and PowerDB (full version, optional)
low-cost method of verifying accuracy class of all types of TTR330: PowerDB ONBOARD
PTs and CTs at “zero burden.”
Transformer Winding Phase Relationship
The phase deviation between the high and low side of a ANSI C57.12.70-1978
transformer is generally very small. If there is deterioration CEI/IEC 76-1:1993 and Publication 616:1978
or damage in the transformer core, however, the phase AS-2374, Part 4-1982 (Australian Standard)
deviation can change significantly. The three-phase TTR Safety/EMC/Vibration
can measure this phase relationship with the resolution of Meets the requirements of IEC-1010-1, CE and ASTM D999.75
0.1 minutes (equal to 1/600 of a degree), which is
Temperature Range
necessary to detect problems.
Operating: 23° F to 122° F (-5° C to 50° C)
Storage: -58° F to 140° F (-50° C to 60° C)
SPECIFICATIONS Relative Humidity
Input Power 0 to 90% noncondensing
120/230 V ac ±10%, single phase, 50/60 ±2 Hz 100 VA Measuring Time
Battery Operation (Optional) 8 to 20 seconds depending on mode of operation and
Inverter 12 V dc to 120 V/230 V ac for operation from vehicle type of transformer
battery Measurement Method
Excitation Voltage ANSI/IEEE C57.12.90
8, 40, or 80 V rms, automatically or manually selected Dimensions
Excitation Current Range and Accuracy 8.5 H x 21.5 W x 13 D in.
0 to 500 mA, 3 digit resolution, ±(2% of reading + 1 digit) (216 H x 546.1 W x 330.2 D mm)

Phase Deviation Range and Accuracy Weight


±90 degrees, 1 decimal point for the minutes display, 2 decimal Instrument only, not including leads
points for the degree display, or for the centi-radian display TTR300: 20 lbs (9.1 kg)
Accuracy: ±3 minutes TTR310: 23 lbs (10.4 kg)
TTR320: 25 lbs (11.3 kg)
TTR330: 25 lbs (11.3 kg)
TTR®300 Series
Three-Phase Transformer Turns Ratio Test Sets

FEATURES AND BENEFITS GUIDE

TTR300 TTR310 TTR320 TTR330

Field upgradeable/interchangeable to any other TTR in the


Series without compromising calibration (patent pending) ■ ■ ■ ■

Remote controllable ■ ■ ■ ■

Works in the presence of high interference/high voltage ■ ■ ■ ■

Displays % error vs. name plate with pass/fail limits ■ ■ ■ ■

Measures the widest turns ratio range in the industry


(45,000:1) and provides the highest accuracy (0.1%) ■ ■ ■ ■

Enables operator to enter the ratio of transformer and all


of its taps letting operator know immediately when a tap ■ ■ ■ ■
is outside acceptable limits so problem can be flagged
Equipped with “Remote TEST” switch for single person
testing, allowing the operator to test transformers with ■ ■ ■ ■
“LTCs” very quickly
Measures phase deviation of the transformer primary
versus secondary; quickly indicates problems in the ■ ■ ■ ■
transformer such as partial shorted turns and core faults.
Useful in verifying phase errors in PTs and CTs
Rugged, lightweight design ideal for a harsh field and
substation environment ■ ■ ■ ■

User selectable standards: ANSI, IEC, and Australian.


Meets IEC 1010 and other standards such as CSA and UL ■ ■ ■ ■

“Quick Test” mode provides a fast determination of


turns ratio for single- and three-phase transformers ■ ■ ■ ■

Units can be operated while in transit case ■ ■ ■ ■

Leads can stay connected while in transit case ■ ■ ■ ■

Printing of test results without the use of a computer N/A 4” thermal 4” thermal 8.5” x 11”
spool paper spool paper thermal paper
Software
PowerDB LITE ■ ■ ■ ■

“PowerDB ONBOARD” allows for operation of


the unit through on-screen customizable test
forms (patent pending) ■

Full version PowerDB Optional Optional Optional Optional


Communications port
Printer interface N/A RS-232 RS-232 USB
Internal data storage (data sets) N/A 200 100,000 100,000
External storage device N/A N/A USB USB
Computer interface RS-232 RS-232 Ethernet Ethernet
User interface
Display type N/A 5.7” B&W 5.7” color VGA 8.4” color VGA
On-screen view N/A Text Graphical icons Test forms
Keypad N/A Numeric QWERTY QWERTY
TTR®300 Series
Three-Phase Transformer Turns Ratio Test Sets

OPTIONAL ACCESSORY LEADS


Our heavy duty leads feature right angle connectors for a
more streamlined look and feel. The larger clips are useful
when clamping onto large transformer bushings.
Please specify catalog number for lead length/configuration
when ordering.

ORDERING INFORMATION
Item (Qty) Cat. No. Item (Qty) Cat. No.
Three-Phase TTR, remote controlled TTR300 Optional Accessories
Three-Phase TTR, stand alone or remote controlled TTR310 PowerDB software, 1st machine license, soft key DB1001
Three-Phase TTR, graphical user interface TTR320 PowerDB, 1st machine license, USB dongle DB1001S
Three-Phase TTR with PowerDB ONBOARD TTR330 Calibration device (for TTR verification) 550555
Note: 120 V 50/60-Hz operation standard. 3-ø lead set adapter to allow use of
For 230 V, 50/60-Hz operation Add -47 to Cat. No. Megger TTR C/N 550503 lead set (30915-xxx) 37087
3-ø shielded test lead set,
Included Accessories X and H winding, 30 ft (9.1 m) 37093
Canvas carrying bag for test leads 30915-211 3-ø shielded test lead set,
Power supply cord, 8 ft (2.5 m) 17032-4 X and H winding, 50 ft (15 m) 37094
Ground lead, 15 ft (4.6 m) 4702-7 1-ø shielded test lead set,
X and H winding, 30 ft (9.1 m) 37095
Hand-held TEST switch assy for remote operation 30915-220
Inverter with 3 ft (0.91 m) cigarette adapter cord
PowerDB LITE DB0001
12 V dc to 120 V ac, 60 Hz 35271-1
RS232 cable for connecting to a PC
for use with TTR300 and TTR310 35248 12 V dc to 120 V ac, 50 Hz 35271-3
Ethernet cable for connecting to a PC 12 V dc to 230 V ac, 60 Hz 35271-2
for use with TTR320 and TTR330 36798 12 V dc to 230 V ac, 50 Hz 35271-4
Bushing clips (6) MC7144 TTR printer package for TTR300, TTR310, TTR320
Transformer Vector Voltage Diagram Set 120 V, 60 Hz 35755-3
(for ANSI, IEC, and AS Standards) for TTR310 35314 230 V, 50 Hz 35755-4
Instruction manuals USB portable thermal printer for TTR330 36493
for TTR300 AVTMTTR300 Thermal paper (8.5” x 11”) for P/N 36493 36809-1
for TTR310 AVTMTTR310 Thermal paper (A4) for P/N 36493 36809-2
for TTR320 AVTMTTR320 Replacement/spare battery pack for P/N 36493 37077
For TTR330 AVTMTTR330 Transit case (for instrument, leads and accessories) 37009
Field Upgrade Kits
TTR330 interface panel 37089-1
TTR320 interface panel 37089-2
TTR310 interface panel 37089-3
TTR300 interface panel 37089-4
Three-Phase TTR®
Transformer Turns Ratio Test Set

SPECIFICATIONS Display
Input Power LCD module, 256 x 128 dots (42 characters by 16 lines)
Cat. No. 550503: Test Result Storage
120 V ac ±10%, single phase, 50 ±2 Hz or 60 ±2 Hz, 100 VA Internal, nonvolatile memory for storing up to 200 sets of three-
Cat. No. 550503-47: phase measured and calculated ratio, exciting current, phase, ratio
230 V ac ±10%, single phase, 50 ±2 Hz or 60 ±2 Hz, 100 VA error, plus serial number and transformer type.
Battery Operation (Optional) Communication/Control Software — ComLink
Inverter 12 V dc to 120 V/230 V ac for operation from vehicle Included ComLink software for data storage, report printout and
battery. download of data to a PC, and control of the TTR via PC.
Excitation Voltage Transformer Winding Phase Relationship
8, 40, or 80 V rms, automatically or manually selected ANSI C57.12.70-1978
CEI/IEC 76-1:1993 and Publication 616:1978
Excitation Current Range and Accuracy
AS-2374, Part 4-1982 (Australian Standard)
0 to 500 mA, 3 digit resolution, ±(2% of reading + 1 digit)
Safety/EMC/Vibration
Phase Deviation Range and Accuracy
Meets the requirements of IEC-1010-1, CE and ASTM D999.75
±90 degrees, 1 decimal point for the minutes display, 2 decimal
points for the degree display, or for the centi-radian display Temperature Range
Accuracy: ±3 minutes Operating: 23° F to 122° F (-5° C to 50° C)
Storage: -58° F to 140° F (-50° C to 60° C)
Turns Ratio Range and Accuracy
8 V ac: ±0.1% (0.8 to 2000) Relative Humidity
±0.25% (2001 to 4000) 0 to 90% noncondensing
±0.35% (4001 to 8000) Measuring Time
40 V ac: ±0.1% (0.8 to 2000) 8 to 20 seconds depending on mode of operation and type of
±0.15% (2001 to 4000) transformer.
±0.3% (4001 to 10,000)
Measurement Method
±0.35% (10,001 to 25,000)
ANSI/IEEE C57.12.90
80 V ac: ±0.1% (0.8 to 2000)
±0.15% (2001 to 4000) Dimensions
±0.25% (4001 to 10,000) 10.5 H x 17.5 W x 6.9 D in.
±0.30% (10,001 to 45,000) (266.7 H x 444.5 W x 175.3 D mm)
Resolution: 5 digit for all ratios Weight
PC/Printer Interface Approx. 16.5 lbs (7.5 kg), instrument only, not including leads
RS232C port, 9-pin 9600 baud

ORDERING INFORMATION
Item (Qty) Cat. No. Item (Qty) Cat. No.
120 V ac ±10%, 50 or 60 Hz, Three-Phase TTR 550503 Optional Accessories
230 V ac ±10%, 50 or 60 Hz, Three-Phase TTR 550503-47 Test leads, 1-ø clip ends, H winding, 10 ft (3.1 m) 30915-506
Included Accessories Test leads, 1-ø clip ends,X winding, 10 ft (3.1 m) 30915-507
Canvas carrying bag for test leads 30915-211 Test leads, 3-ø clip ends, H winding, 20 ft (6.2 m) 30915-524
Power supply cord, 8 ft (2.5 m) 17032-4 TTR Printer Package
Ground lead, 15 ft (4.6 m) 4702-7 120 V, 60 Hz 35312-1
3-ø shielded test leads, H winding, 10 ft (3.1 m) 30915-505 230 V, 50 Hz 35312-2
3-ø shielded test leads, X winding, 10 ft (3.1 m) 30915-504 Includes Battery/line-powered serial thermal printer,
Shielded extensions, H winding, 33 ft (10 m) 30915-503 printer interface cable, and shelf for mounting printer

Shielded extensions,X winding, 33 ft (10 m) 30915-502 Calibration Standard (for TTR verification) 550555

Hand-held switch assy for remote operation 30915-220 Inverter with 3 ft (0.91 m) cigarette adapter cord

ComLink software 35794-2 12 V dc to 120 V ac, 60 Hz 35271-1

RS232 cable for connecting to a PC 35248 12 V dc to 120 V ac, 50 Hz 35271-3

Bushing clips (6) MC7144 12 V dc to 230 V ac, 60 Hz 35271-2

Transformer Vector Voltage Diagram Set 12 V dc to 230 V ac, 50 Hz 35271-4


(For ANSI, IEC, and AS Standards) 35314 Transit case (for instrument leads and accessories) 35313
Instruction manual AVTM550503

ISO STATEMENT
Registered to ISO 9001:1994 Reg no. Q 09250

Registered to ISO 14001 Reg no. EMS 61597

THREE_PHASE_TTR_DS_en_V12
Item 3B
TTR™100
Single-Phase Handheld TTR

TTR™100
Single-Phase Handheld TTR
■ Fully automatic; fast; easy-to-use;
handheld; robust; lightweight
■ Battery powered with power-saving and
shutdown function
■ Tests turns ratio, phase displacement,
excitation current, vector group, winding
resistance and polarity
■ Alphanumeric keyboard
■ RS232 for data transfer and printing
■ Stores 200 test results and 100 user-
defined transformer test settings
■ Six user-selectable languages

DESCRIPTION The TTR100 comes equipped with specially designed leads


The Megger TTR100 is an automatic single-phase which provide the necessary flexibility needed in all
handheld, battery operated transformer turns ratio test set weather conditions.
used to measure the turns ratio, excitation current, phase
This unit measures the highest turns ratio in the industry
displacement, dc resistance and polarity of windings in
with an accuracy of 0.1% or better and with the lowest
single- and three-phase distribution transformers (tested
excitation voltage. No other instrument’s performance is
phase by phase), potential & current transformers, and
comparable that is commercially available today. Another
tapped transformers. Deviations in the mentioned
excellent feature of this TTR is the ability to accurately
measurements will quickly indicate problems in
measure phase deviation (in minutes or centiradians) of
transformer windings or in the magnetic core circuits.
the transformer primary versus secondary. This
The unique design of the TTR100 allows the user to measurement is also useful in verifying phase errors in PTs
operate the test set while holding it in one hand. No other and CTs.
transformer test set offers this capability. It effectively
The TTR100 features special software capabilities. It comes
eliminates the user from having the kneel or bend over to
equipped with sufficient onboard memory to store up to
operate the instrument and speeds up testing time.
200 test results (including test report header information)
Realizing the extreme environments in which the TTR100 in the field for later retrieval, as well as 100 user-defined
must operate, special attention has been paid to making it transformer settings. Test results can be printed on an
extra rugged, with a high impact, shock resistant case, yet optional serial printer whenever a hard copy is desired, or
incredibly lightweight (3.3 lb). It weights less than any the data can be downloaded to a PC. Identification of
other commercially available instrument on the market. individual test readings is also easily done. The system
software allows entry of the transformer alphanumeric
Its rugged and robust design makes this instrument well
serial number, transformer type and tap information
suited for use in a variety of harsh environments. The
(numerical, alphabetical, or alpha-numerical) for each test
TTR100 is particularly suited for testing in substations and
performed.
transformer-manufacturing environments where testing
single and three-phase transformers can be performed. The TTR100 comes with a Windows® based software
The TTR100 provides reliable results, helping the user in program that permits download of test data from the
determining the condition of the transformer under test. It instrument to a PC database. Data stored in the database
features a high contrast LCD screen which can be seen in can be retrieved at a later date and test reports can be
bright or ambient light. printed to assist in the preparation of management and/or
analysis reports. These reports are easily transmitted via e-
mail.
TTR™100
Single-Phase Handheld TTR

APPLICATIONS The Megger TTR100 can measure the DC resistance of


The proper operation of a transformer relies almost both single phase and three phase transformer windings.
entirely on the electrical properties of its windings. To
Transformer Polarity
ensure continued proper operation, transformers are tested
to verify that their electrical properties have not changed Polarity of a distribution transformer becomes of interest in
from design specifications. A TTR is an extremely useful order to determine its proper connection within a power
instrument for testing transformer windings because it can network.
locate several types of problems within a single- or a The Megger TTR100 will identify subtractive and additive
three-phase transformer. It is also ideal to use for testing in polarity of the single-phase distribution transformers.
meter shops for the inspection of CTs and PTs. It can
determine the no-load accuracy of CTs and PTs and also
determine the need to further test faulty CTs and PTs. FEATURES AND BENEFITS
■ Faster, easier handheld operation. User no longer has to
The TTR100 applies voltage, with voltage ratio being kneel or bend down to operate the instrument.
directly proportional to turns ratio, to the high-voltage
■ Powered by rechargeable battery, provides up to fifteen
winding of a transformer and accurately measures the
resulting voltage from the low voltage winding. In addition hours of field operation.
to turns ratio, the unit measures excitation current, phase ■ Report header information such as company name,
angle deviation between the high and low voltage substation name, transformer manufacturer, transformer
windings, percent ratio error, dc winding resistance and ratio, operator, temperature and %RH can be entered and
polarity. saved via the alphanumeric keypad.
Transformer Turns Ratio ■ Measures the widest turns ratio range in the industry
Transformer Turns Ratio is the ratio of the number of turns (20,000:1) with the highest accuracy (±0.1%, 0.8 to 2000) at
in the high voltage winding to that in the low voltage a low excitation voltage.
winding.
■ Enables the operator to enter the ratio of the transformer
A Transformer Turns Ratio Test Set such as the TTR100 can and all of its taps. This allows the operator to know
directly measure the ratio of single phase, as well as three immediately when a tap is outside the acceptable limits so
phase transformers. Transformer ratio can change due to that problem taps can be easily identified.
several factors, including physical damage from faults,
■ Records ratio errors for bushing CTs to an accuracy of
deteriorated insulation, contamination and shipping
±0.1% nameplate. This reduces the need for additional test
damage. If a transformer ratio deviates more than 0.5
equipment and improves set-up time.
percent from the rated voltage ratio, it may not operate
reliably. To measure small ratio changes such as this, the ■ Measures the phase deviation (in minutes, degrees or
accuracy of a Megger TTR100 is needed. centiradians) of the transformer primary versus secondary.
This quickly indicates problems in the transformer such as
Excitation Current
partial shorted turns and core faults. This measurement is
The TTR100 is capable of measuring exciting current by also useful in verifying phase errors in all types of PTs and
applying voltage to one of the transformers windings. An CTs.
accurate measurement of exciting current can provide
■ Perfect for meter shops, the TTR100 can be used for
information about the condition of a transformer’s core.
Unwanted circulating currents or unintentional grounds inspection purposes by using it to determine the no-load
can affect the exciting current and indicate a problem. accuracy of most CTs and PTs. It also can be used to
determine the need to further test potentially faulty CTs
Phase Angle Deviation and PTs.
The phase angle deviation is the relationship between the
■ The TTR100 is ideal for use by transformer
voltage signal applied to the high voltage winding and the
manufacturers. Its unique testing procedures and storage
voltage signal extracted from the low voltage winding.
capability allows an operator to set up and test single and
The phase deviation between the high and low side of a three-phase transformers (with multiple tap changers and
transformer is generally very small. However, the phase bushing CTs) in minimal time.
deviation can change significantly if there is deterioration
■ A “Quick Test” mode provides a fast determination of
or damage in the transformer core. The TTR100 can
the turns ratio, excitation current, phase angle deviation,
measure this phase relationship with the resolution
and winding resistance in single- and three-phase
necessary to detect a problem.
transformers and CTs. In addition, polarity is provided for
Additional information about a transformer’s electrical CTs and single-phase transformers.
properties can be found in the IEEE Standard Test Code
■ Displays all measured and calculated values for each test
for Transformers, C57.12.90, or by contacting Megger’s
including ratio, excitation current, ratio error, phase angle
technical support group.
deviation, transformer vector group, winding resistance
Winding Resistance and polarity thus providing comprehensive and conclusive
Measuring the DC resistance of transformer windings will data
aid in identifying problems such as shorted or open ■ Automatic self-calibration for each test.
windings, as well as loose connections.
TTR™100
Single-Phase Handheld TTR

■ Rugged, lightweight design ideally suited for a harsh Winding Resistance Accuracy
field and substation environment. ±(10% of reading + 1 digit) for 10 Ω to 2000 Ω range
±(10% ±1 mΩ) for 10 mΩ to 9.99 Ω range
■ Three user selectable standards: ANSI, IEC, and ±(10% ±0.5 mΩ) for 0.1 mΩ to 9.99 mΩ range
Australian. Also meets IEC1010 as well as CE.
■ Six user selectable languages: English, French, German, PC/Printer Interface
Italian, Portuguese and Spanish. RS232C port, 9-pin, 57.6 Kbaud (19.2 Kbaud for the printer)
Display full graphics
SPECIFICATIONS LCD module, wide temperature range, 128 x 64 dots (21
characters by 8 lines)
Type of Power
Rechargeable NIMH battery pack, 3.6 V dc, 3800 mAh Test Result Storage
Internal, nonvolatile memory for storing up to 200 sets of single-
Battery Life phase measured and calculated ratio, exciting current, phase, ratio
15 hours of field operation error, winding resistance, polarity, vector group, plus header
information (company, substation, transformer manufacturer,
Charger input voltage
transformer rating, instrument serial number, temperature, relative
100-250 V ac, 50/60 Hz ±2 Hz Unit can be operated while
humidity, and operator name)
charging. Charging time is approximately three hours
In addition, up to 100 user-defined transformer settings can be
Optional charger source stored.
Optional inverter 12 V dc to 115 V ac for powering a charger from
Computer Software
vehicle battery (non CE marked)
Included software for downloading of data to a PC, data storage
Excitation Voltage to database and report printout.
8 V rms for testing distribution or power transformers, and PTs;
Test Leads
1.5 V ac RMS, or 8 V ac RMS for testing CTs.
Supplied with one complete set of single-phase leads, 6 ft (1.8 m)
The excitation voltage is switched automatically if excitation
in length
current exceeds a preset value.
Transformer Winding Phase Relationship
Test Frequency
ANSI C57.12.70-1978
55 Hz internally generated providing a universal 50/60 Hz test set
CEI/IEC 76-1:1993 and Publication 616:1978
Excitation Current Range AS-2374, Part 4-1982 (Australian Standard)
0 to 100 mA, 4-digit resolution
Safety/EMC/Vibration
Turns Ratio Range Meets the requirements of IEC-1010-1, CE and ASTM D999.75
8 V ac: 0.8 to 20,000, 5 digit resolution (for transformers and PT
Temperature Range
testing)
Oper atin g: -4º F to 131º F (-20º C to 55º C)
1.5 V ac: 5.0 to 2200, 5 digit resolution (for CT testing)
Stor age: -58º F to 140º F (-50º C to 60º C)
Phase Deviation Range
Relative humidity
±90º, 1 decimal point for the minutes display, 2 decimal points for
Oper atin g: 0 to 90% noncondensing
the degree display, or for the centiradian display
Stor age: 0 to 95% noncondensing
Winding Resistance Range
Protective Devices
0 to 2000 Ω, 4 digit resolution
High voltage side shorting relays, transient voltage suppressors
Transformer Vector Group and gas surge voltage protectors
1PH0 or 1PH6
Measuring Time
Transformer Polarity 8 to 20 seconds for a single-phase distribution transformer
Additive or Subtractive
Measurement Method
Current (rms) accuracy ANSI/IEEE C57.12.90
±(2% of reading + 1 digit)
Dimensions
Phase Deviation Accuracy 9.5 H x 4.5 W x 1.875 D in. (241 H x 115 W x 48 D mm)
±3 minutes
Weight
Turns Ratio Accuracy Approx. 3.3 lbs (1.5 kg), instrument only, without leads
±0.1% (0.8 to 2000)
Protective Instrument Carrying Case
±0.15% (2001 to 4000)
Neoprene case with carrying strap and attachable pouch for
±0.20% (4001 to 10,000)
universal charger and 6 ft. (1.8 m) test leads, single-phase
±0.25% (10,001 to 20.000)
connection (two leads for the H winding and three leads for the
secondary winding with tap).
TTR™100
Single-Phase Handheld TTR

OPTIONAL ACCESSORIES MEGGER


Power Inverter 1-ph. TRANSFORMER TURN RATIO TESTER
Catalog No. TTR100
It may be necessary to have a
TRANSFORMER TEST REPORT
portable power source in the
field. A power inverter using a COMPANY: SOUTHWEST ENERGY
SUBSTATION: HARDWOOD
vehicle’s battery can provide MANUFACTURER: DELTA-STAR, IL
the energy to the battery TRANSFORMER RATING: 375 KVA
AMBIENT TEMPERATURE: 78 F
charger in order to power up RELATIVE HUMIDITY: 83%
the TTR100. The optional TTR S/N: 200308001
OPERATOR(S): MIKE BRIGHT
inverter can be connected to COMMENTS/NOTES:
the vehicle’s cigarette lighter. TEST DATE (M/D/Y): 04/15/03 09:27
The inverter’s output provides a true sine wave rated to TEST NO: 033
TRANSFORMER ID: 3AG-872B/AD39AM
deliver 60 watts of ac power continuously or 75 watts of H VOLTAGE, V: 13800
power for 5 minutes. It is also protected with features that X VOLTAGE, V: 240
CALCULATED TURNS RATIO: 57.500
will automatically shut off in case of under-voltage, over-
voltage, and over-temperature. (Non CE marked.) TEST VOLTAGE: 8 V
TRANSFORMER POLARITY: SUBTRACTIVE
TRANSFORMER VECTOR GROUP: 1PH0
Test Leads
RATIO: N1 57.536 DEV. N1:0.06%
A set of 12 ft (3.6 m) test PHASE N1 (min): -1.5 Rx12 (Ohm): 0.127
leads is available for testing RATIO N2: 56.978 DEV. N2: -0.04%
larger transformers (two PHASE N2 (min): 0.7 Rx32 (Ohm): 0.119
leads for the H winding Exc. I (mA): 0.12 RH (Ohm): 191.6
and three leads for the
secondary winding with
tap). Figure 1: Sample Single-phase three-wire series connection
transformer test report

Printer
Test results, including
transformer vector group, can
be documented using an
optional thermal printer which
is easily attached to the TTR.
A sample test report is shown
in Figure 1.

Battery Pack (not shown)


A NIMH battery pack for use when additional testing time
is required. The battery pack can be charged in the
TTR100 while it is in use or not.
Rated at 3.6 V dc, 3800 mAh
Transit Case (not shown)
Rugged semi-hard padded case for storing/shipping the
instrument, all leads and other accessories.
TTR™100
Single-Phase Handheld TTR

ORDERING INFORMATION
Order a TTR100 configured to your specific application. To determine the catalog number, fill in the blanks below with the
corresponding number from the detailed information boxes.
Ordering Example:
To order a TTR100 for North American application, without a deluxe kit, and instruction
manual in the English language, request catalog number TTR100-NA0-ENG TTR100 — N A 0 — E N G
To order a TTR100 for North American application, with a deluxe kit, and instruction
manual in the English language, request catalog number TTR100-NA1-ENG TTR100 — N A 1 — E N G
Fill in these blanks with the corresponding letter or number.
TTR100 — X X X — X X X

Country
NA = North America Instruction Manual
UK = United Kingdom ENG = English
EU = European Union FRN = French
(Determines power cord requirement) SPN = Spanish

Deluxe Kit Option


0 = No Kit
1 = Deluxe Kit, 120 V, 60 Hz printer
package
2 = Deluxe Kit, 230 V, 50 Hz printer
package

(Kit consists of TTR100, included


accessories as well as all optional
accessories, excluding Inverter P/N
35973)

Item (Qty) Cat. No.


Included Accessories
Test Leads
"X" winding, 6 ft (1.8 m) 35502-511
"H" winding, 6 ft (1.8 m) 35502-521
PC interface cable 33147-18
Battery pack 35753
Universal battery charger 35757
Power cable for battery charger Determined by Country
Protective neoprene carrying case and accessory pouch 55-20008
Software for uploading test results to a PC 35794-2
Quickstart guide 55-20013
Instruction manual AVTMTTR100-XXX
(XXX = language code)
Optional Accessories
Test Leads
"X" winding, 12 ft (3.6 m) 35502-510
"H" winding, 12 ft (3.6 m) 35502-520
Semi-hard fabric transport case 35788
Additional battery pack 35753
Inverter cigarette adapter with power cable, 12 V dc to 115 V ac, 60 Hz, non CE marked 35973
Printer package, including battery/line power serial thermal printer with paper,
battery pack, battery charger, printer interface cable, 120 V, 60 Hz 35755-1
Printer package, including battery/line power serial thermal printer with paper,
battery pack, battery charger, printer interface cable, 230 V, 50 Hz 35755-2
Additional printer paper (1 roll) 27705-1
Optional Accessories are ordered separately or with Deluxe Kit
Item 3C
TTR™25
Handheld TTR

TTR™25
Handheld TTR
■ Single- and three-phase
transformer testing
■ Fully automatic; fast; easy-to-use;
robust; lightweight
■ Battery powered
■ Tests turns ratio, excitation current,
and polarity
■ Simple, one-button operation
■ Quick-start guide on front panel
■ Operator-selectable languages

DESCRIPTION to verify that their electrical properties have not changed


The Megger TTR25 is an automatic hand-held battery from design specifications. A TTR is an extremely useful
operated transformer turns ratio test set. It is used to instrument for testing transformer windings because it can
measure the turns ratio, excitation current and polarity of help locate several types of problems within single- and
windings in single- and three-phase distribution and power three-phase transformers.
transformers (tested phase by phase), potential & current
It it used to determine the no-load accuracy of CTs and
transformers, and tapped transformers.
PTs and also determine the need to further test faulty CTs
The unique design of the TTR25 allows the user to operate and PTs. The TTR25 applies voltage to the high-voltage
the test set while holding it in one hand. It effectively winding of a transformer and accurately measures the
eliminates the user from having to kneel or bend down to resulting voltage from the low voltage winding. The ratio
operate the instrument and speeds up testing time. of voltages is directly proportional to turns ratio. In
Realizing the extreme environments in which the TTR25 addition, the unit measures excitation current and polarity.
must operate, special attention has been paid to making it
extra rugged, with a high impact, shock resistant case, yet
incredibly lightweight at a mere 870 g (1.9 lbs). Transformer Turns Ratio
A Transformer Turns Ratio Test Set such as the TTR25 can
Its design makes this instrument well suited for use in a directly measure the turns ratio of single-phase
variety of harsh environments. The TTR25 is particularly transformers as well as three-phase transformers.
suited for testing in substations, transformer-manufacturing Deviations in these measurements will quickly indicate
environments, and meter shops. It features a high-contrast, problems in transformer windings and in the magnetic
backlit LCD screen which can be seen in bright or ambient core circuits. Transformer ratio can change due to several
light. factors, including physical damage from faults, deteriorated
This unit measures a high turns ratio of 20,000:1 accurately insulation, contamination and shipping damage. If a
with the lowest excitation voltage. The excellent transformer ratio deviates more than 0.5 percent from the
repeatability of the TTR25 helps the users to determine the rated voltage ratio, it may not operate reliably. To measure
condition of transformers under test. It is designed for small ratio changes such as this, the accuracy of a Megger
simple, one button operation with the measured results TTR25 is needed.
displayed directly on the easy to read LCD or printed to Transformer Polarity
the optional printer. The TTR25 needs no additional
Polarity of a distribution transformer becomes of interest in
software and comes ready to use complete out of the box.
order to determine its proper connection within a power
network. The Megger TTR25 will identify normal (in
APPLICATIONS phase) and reverse polarity of the single-phase
The proper operation of a transformer relies almost transformers.
entirely on the electrical properties of its windings. To
ensure continued proper operation, transformers are tested
TTR™25
Handheld TTR

FEATURES AND BENEFITS Display full graphics


■ Fast, easy hand-held operation. No need to kneel or LCD module, adjustable back-lighting, wide temperature range,
bend down to operate the instrument. 128 x 64 dots (21 characters by 8 lines)

■ Powered by six standard “AA” alkaline batteries; no Transformer Winding Phase Relationship
ANSI C57.12.70-1978
charger needed. Provides up to 12 hours of field
CEI/IEC 76-1:1993 and Publication 616:1978
operation. AS-2374, Part 4-1982 (Australian Standard)
■ Measures turns ratio range of 20,000:1, with a high Safety/EMC/Vibration
accuracy (±0.1%, 0.8 to 2000) at a low excitation voltage. Meets the requirements of IEC-1010-1, CE and ASTM D999.75
■ Records ratio errors for bushing CTs to an accuracy of Temperature Range
±0.1% nameplate. This reduces the need for additional Operating: -20º C to 55º C (-5º F to 130º F)
test equipment and improves set-up time. Storage: -50º C to 60º C (-55º F to 140º F)

■ Perfect for meter shops, the TTR25 can be used for Relative humidity
inspection purposes to determine the no-load accuracy Operating: 0 to 90% noncondensing
of most CTs and PTs. It also can be used to determine Storage: 0 to 95% noncondensing
the need to test potentially faulty CTs and PTs. Protective Devices
High voltage side shorting relay, transient voltage suppressors and
■ Automatic self-calibration for each test.
gas surge voltage protectors
■ User selectable languages: English, Spanish, German, Measuring Time
French and Portguese. Less than 5 seconds
Measurement Method
SPECIFICATIONS ANSI/IEEE C57.12.90
Type of Power Dimensions
Six standard “AA” (IEC LR-6) alkaline batteries 240 H x 115 W x 50 D mm (9.5 H x 4.5 W x 1.9 D in.)
Battery Life Weight
12 hours of field operation Approximately 1.3 kg (2.8 lb), including leads
Excitation Voltage
8 V rms for testing distribution or power transformers and PTs;
0.5, 1.5, or 8 V ac rms for testing CTs.
The excitation voltage is switched automatically if excitation
ORDERING INFORMATION
current exceeds a preset value. Item (Qty) Cat. No.
Test Frequency Hand-held TTR25 TTR25
55 Hz internally generated providing a universal 50/60 Hz test set
Included Accessories
Excitation Current Range Combined test leads, "X/H" winding, 1.8 m (6 ft) 35938
0 to 100 mA, 4-digit resolution
Instruction manual AVTMTTR25
Turns Ratio Range Electronic documents AVTDTTR25
0.8 to 20,000, 5 digit resolution
Optional Accessories
Transformer Polarity
Combined test leads, "X/H" winding, 3.6 m (12 ft) 35942
Normal or reversed
Combined test leads, “X/H” winding, 6 m (20 ft) 36013
Current (rms) accuracy
Printer package including battery/line power
(2% of reading + 1 digit)
serial thermal printer with paper, battery pack
Turns Ratio Accuracy and charger, printer interface cable, 120V, 60Hz 35755-1
0.1% (0.8 to 2000) Printer package including battery/line power
0.15% (2001 to 4000) serial thermal printer with paper, battery pack
0.25% (4001 to 20,000) and charger, printer interface cable, 230V, 50Hz 35755-2
Semi-hard fabric transport case 35788
Quick-guide overlay in Spanish, French,
German and Portuguese 35945
Item 3D
SINGLE-PHASE TTR®
TRANSFORMER TURNS RATIO TEST SET

SINGLE-PHASE TTR®
Transformer Turns Ratio Test Set

■ Used for testing single phase power and


distribution transformers
■ Design based on precision bridge
measuring technique
■ Available in hand-cranked or line-operated
models
■ Unmatched accuracy ((0.1%) in a portable
design

DESCRIPTION APPLICATIONS
The Single Phase TTRº Transformer Turns Ratio Test Set The single phase models are primarily used for testing single-
measures the turns ratio and exciting current of windings in phase power and distribution transformers, for low-ratio
power, potential and current transformers. Deviations in turns readings up to 129.99:1, or up to 329.99:1 with an auxiliary
ratio readings indicate problems in one or both windings or transformer.
the magnetic core circuit. They also can be used to test three-phase transformers by
The TTR test set aids in identifying: connecting and testing each phase separately.
■ Shorted coils
FEATURES AND BENEFITS
■ Open circuits ■ Available in hand-cranked or line-operated models, these
■ Incorrect connections units provide unmatched accuracy ((0.1%) in a portable
design.
■ Internal faults or tap-changer defects in step regulators as
well as in transformers. ■ Rack-mounted model is suitable for routine production
testing by transformer manufacturers or repair shops. This unit
The single phase model is available in either hand-cranked
is line-operated.
or line-operated versions and measures highly sensitive
turns ratios of up to 129.99:1 with accuracy of (0.1%. An ■ Line-operated model for shop or field testing is packaged
optional auxilary transformer extends the ratio range to in a rugged, metal case.
329.99:1. ■ Measures highly sensitive turn ratios up to 129.99:1. An
The TTR set operates on the principle that the voltage ratio of the optional auxiliary transformer extends this ratio range to
transformer at no load is practically equal to the true turns 329.99:1.
ratio.
The major source of error in a transformer is a primary imped-
ance drop due to magnetizing current, which is kept to a
minimum by excitation at a fraction of rated voltage. By
employing a design that meets both of these conditions along
with the use of a null balance system, the turns ratio of a
transformer can be determined accurately.
When measuring the turns ratio of distribution and power
transformers, the accuracy is well within 0.1%.
SINGLE-PHASE TTR®
TRANSFORMER TURNS RATIO TEST SET

SPECIFICATIONS
Output
8 V, 50/60 Hz. Line-operated models supply up to 5 A for testing specialty power transformers having a high ratio and a low secondary voltage.
Metering
Four decade dials

Range Dimensions
Power CAT.
Model Turn Exciting Accuracy Weight
Source NO.
Ratio Current H x W xD
7.5 H x 14 W x 12 D in. 16 lb
Hand-cranked 0 to 1 A** 189 H x 353 W x 302 D mm (7.3 kg) 550005
Single-phase
field sets 0.001 to 12 H x 12 W x 30 D in. 26 lb
Line* 550027
129.999 (0.1% 300 H x 300 W x 756 D mm (11.8 kg)
0 to 5 A**
Single-phase 10 H x 10.5 W x 19 D in. 22 lb
Line* 550022
rack mounted 255 H x 267 W x 483 D mm (10 kg)
* 120 Va c, 50/60 Hz. To order 240 Va c, 50/60 Hz, add –47 to Cat. No.
** Divide by 5 switch for increased resolution

OPTIONAL ACCESSORIES Calibration Reference Transformer


Calibration reference transformers are available for both
Auxiliary Transformer
single- and three-phase test sets. They provide a reference
An auxiliary transformer
standard for periodic calibration checks to document proof
extends the ratio range of
of calibration.
single-phase models to
329.99:1. Turns ratio is 100:1 A Calibration Certificate of
and 200:1, and is accurate to Turn Ratio Accuracy traceable
within (0.1%. to the NIST is furnished with
each calibration reference
The auxiliary transformer
transformer, providing accura-
includes all the necessary cables
cies of (0.05%.
for connection to the TTR set
and the transformer under test. Dimensions
8 H x 14 W x 10 D in.
Dimensions
203 H x 356 W x 254 D mm
8 H x 13 W x 10 D in. (203 H x 330 W x 254 D mm)
Weight: 11 lb (5.0 kg)
Weight: 13 lb (5.9 kg)

ORDERING INFORMATION
Item (Qty) Cat. No. Item (Qty) Cat. No.
Single-phase TTR
Hand-cranked 550005
Included Accessories
Line operated, 120 Vac, 50/60 Hz 550027
Cable assembly 19494
Line operated, 240 Vac, 50/60 Hz 550027-47
With C-clamps for X (low-voltage) winding,
Rack-mounted, line, 120 Vac, 50/60 Hz 550022
10 ft (3 m) [2]
Rack-mounted, line, 240 Vac, 50/60 Hz 550022-47
With spring clips for H (high-voltage) winding,
13 ft (4 m) [2]
All cables are permanently connected to the test set.
Instruction manual AVTM55JD

Optional Accessories
Auxiliary transformer 550030
Calibration reference transformer 550050
Item 3E
(2008/2009)
Item Description

12B Dissolved Gas Analysis with Automatic Degassing unit According to


IEC567 /ASTM 3612 type Top Toga GC.

13 Transformer Fault Indicator (Online Monitoring)

13A Transformer monitoring unit type Hydrocal1002 complete with


Hydrosoft software for data transfer and data administration

13B Transformer monitoring unit type Hydrocal1003 as Hydrocal 1002 but


with additional Water in oil/ moisture measurement.

14 High Voltage Lab for AC, DC and Impulse Testing can be provided
on request.

15 Transformer Electrical Workshop

A complete transformer repair workshop including Winding / Rewinding


Coil Winding Machines, Ovens, Essential Tools and other Accessories
can be provided on request.
4.Capacitance +
Dissipation Factor (Tan
Delta) Test Sets
Item 4A
DELTA-2000
10 kV Automated Insulation Power Factor Test Set

DELTA-2000
10 kV Automated Insulation
Power Factor Test Set
■ Extremely easy to use, without any
extensive hardware or software setup
■ Designed to work in high interference
switchyards of up to 765 kV
■ Built-in capability for storing, printing
and downloading test results
■ Rugged, portable design for field/shop
shop use with automated control via the
PowerDB™ software package
■ Optional HV reference capacitors
(100 pF, 1000 pF) with 2% dissipation
factor, and a 10 nF TTR capacitor
■ Optional Priority Access package offering
exclusive services/support

DESCRIPTION The Priority Access program provides specific guaranteed


The DELTA-2000 is a fully automatic 10 kV insulation support to assure full utilization of the Megger
power factor test set designed for condition assessment of DELTA-2000. The purchase of the program entitles the user
electrical insulation in high voltage apparatus, such as free services for one year from receipt of the unit.
transformers, bushings, circuit breakers, cables, lightning
arresters and rotating machinery.
FEATURES AND BENEFITS
This set has been designed to provide a comprehensive ■ Fully automatic operation eliminates operator error and
AC insulation diagnostic test. Measurements are performed reduces testing time.
automatically by the DELTA-2000, and results are ■ Simplified operation procedure eliminates the need for
displayed on a large graphical LCD. Measured quantities
extensive software or hardware setups.
include voltage, current, power (loss), power factor and
capacitance. The operator has the option of correcting the ■ Performs all standard ungrounded-specimen tests (UST)
current and loss readings to their 2.5 kV or 10 kV and grounded-specimen tests (GST), with or without a
equivalents. An optional 10 nF TTR capacitor in addition guard circuit.
to two HV reference capacitors are also available.
■ Utilizing the automatic suppression circuitry achieves
The built-in tracking automatic interference suppression high accuracy measurement under severe electrostatic
circuit ensures accurate and reliable test results under and electromagnetic interference conditions.
severe electrostatic and electromagnetic interference
■ Two-piece design reduces size and weight of the system
conditions. This feature allows the performance of test
and provides easier transportation.
measurements in energized switchyards of up to 765 kV.
■ Built-in self diagnostic and calibration check.
The operator has the option of storing the test results on
the provided data key, or download directly to a PC or ■ The operator has the option of measuring either the
the included thermal printer. A small printer mounting can power factor or dissipation factor (tan ∂).
be installed inside the unit’s lid in lieu of the standard
■ Open-ground detector ensures proper grounding before
printer that is included. The data key has storage capacity
test.
for 127 sets of test results. Information stored on the data
key can be easily retrieved on a PC using the provided ■ Interlock switches provide operator safety.
software program and interface box.
■ Built-in interface to the optional Resonating Inductor
In addition to performing insulation power factor tests, the (Cat. No. 670600) to extend the capacitance measuring
DELTA-2000 can be used for measuring the excitation range to 1µF at 10 kV.
current of transformer windings.
DELTA-2000
10 kV Automated Insulation Power Factor Test Set

■ Data key stores 127 sets of test results for retrieval and Power Factor
analysis. Stored results can be easily transferred to a PC ±(2% of reading + 0.05%)
using the provided interface box. Watt-loss
■ Optional printer mounting inside unit’s lid instead of ±(2% of reading + 1mW)
standard thermal printer. Measurement
The following seven test modes are available, using the blue and
■ Optional TTR capacitor (10 nF) in addition to two HV red measuring leads, and can be selected by the operator:
reference capacitors (100 pF and 1000 pF) with a 2% UST: Ground Red, Measure Blue
dissipation factor. UST: Ground Blue, Measure Red
UST: No Ground, Measure to both Red and Blue
■ RS-232 serial interface for downloading the test results to a
GST: No Guard
PC.
GST: Guard Blue, Ground Red
■ Includes a battery/line operated printer for a hard copy GST: Guard Red, Ground Blue
of the test results which are date and time stamped. GST: Guard Red, and Blue, No Grounding
UST: Ungrounded Specimen Testing
■ Optional bar code wand and PC software for recording GST: Grounded Specimen Testing
an alphanumeric test identification in the field.
Test Frequency
■ Optional Priority Access package with exclusive services. Same as line frequency

■ Optional Oil Test Cell for testing insulating fluids up Interference Suppression
to 10 kV. Available Suppression Methods
1. Operator selectable automatic forward/reverse measurement
■ Optional Calibration Standard verifies proper operation averaging.
and accuracy of the test results. 2. Operator selectable automatic tracking interference cancellation.

■ Interfaces with a PowerDB™ software package that Safety Qualifications


performs extensive information processing, data trending The test set meets the requirements of both the IEC-1010 and the
CE mark specifications. The test set also meets the shock and
and report generation.
vibration requirements of the ASTM D999.75 standard.
Environment
SPECIFICATIONS
Temperature
Input Operating: 32 to 122° F ( 0 to 50° C),
120 V ±10%, 1 , 60 Hz, 1440 VA Storage: -58 to +140° F (-50 to +60° C)
Output Relative Humidity
0 to 12 kV, continuously adjustable, 100 mA continuous, maximum Operating: 0 to 90% non-condensing
200 mA (15 minutes on, 15 minutes off, maximum 8 tests). The Storage: 0 to 95% non-condensing
power supply capacity can be expanded to 4 Amps using the
Dimensions
optional Resonating Inductor, catalog number 670600.
Control Unit
Accuracy 15 H x 22 W x 16 D in.
Voltage (381 H x 559 W x 406 D mm)
(RMS) ±(1% of reading + 1 digit) High Voltage Unit
Current 15 H x 22 W x 16 D in.
(RMS) ±(1% of reading + 1 digit) (381 H x 559 W x 406 D mm)

Capacitance Weight
±(0.5% of reading + 2 pF) in UST mode Control Unit: 74 lb (33kg)
±(0.5% of reading + 6 pF) in GST mode High Voltage unit: 63 lb (29 kg)
Cables: 35 lb (16 kg)
Measuring Ranges
Voltage
250 V to 12 kV, 10 V resolution. Minimum recommended voltage
is 500 V.
Current
0 to 5 Amps, 1µA maximum resolution. The measurement can be
corrected to either 2.5 kV or 10 kV equivalents.
Capacitance
1 pF to 1.1 µF, 0.01 pF maximum resolution.
Power Factor
0 to 90%, 0.01% max. resolution.
Watt-loss
0 to 2 kW, actual power, 0 to 100 kW when corrected to 10 kV
equivalent. 0.1 mW maximum resolution. The measurement can be
corrected to either 2.5 kV or 10 kV equivalents.
Data Keys with PC interface box and standard thermal printer
DELTA-2000
10 kV Automated Insulation Power Factor Test Set

OPTIONAL ACCESSORIES

The optional Resonating


Inductor expands the
capacitance range of the Optional capacitor kit includes carry case, TTR capacitor (left), and 2
DELTA-2000 reference capacitors (center). Also shown are 2 connectors (right) that
will work with the capacitors and are supplied with the DELTA-2000 unit.

The optional Calibration


Standard traceable to the
NIST for quick operating or
The optional accessory kit, C/N 670501 includes mini bushing tap calibration checks of test set
connectors, hot collar straps, temperature/humidity meter, .75” bushing bridges calibrated in watts
tap connector, 1” bushing tap connector, “J” probe bushing tap loss or in dissipation factor
connector, 3-ft non-insulating shorting leads, 6-ft non-insulating
shorting leads

The optional Oil Test


Cell is used for
testing insulating
fluids up to 10 kV

Optional printer mounted in lid

Optional bar code wand for recording


an alphanumeric test identification
DELTA-2000
10 kV Automated Insulation Power Factor Test Set

PowerDB™ Acceptance & Maintenance


Test Data Management Software
The DELTA-2000 is controlled and automated by the
PowerDB management system, a powerful software
package providing data management for acceptance and
maintenance testing jobs. Customer/contract information is
quickly sorted and searched. Opening a specific record
shows detailed information such as type of service, order
date, sales contact, and invoice information. Job
information can be transferred between field-use databases
and a master database. Job/Device Productivity Reports
aid in bidding future jobs as well as personnel evaluation.
Electrical utilities who have invested in sophisticated
Computerized Maintenance Management Systems (CMMS)
can easily link with the PowerDB software because it
works with a number of systems.
The package also provides test documentation and Data entry and automated control of Megger DELTA-2000
trending, report generation and a number of other optional
add-ons that are described in the Megger PowerDB data
sheet

ORDERING INFORMATION
Item [Qty] Cat. No. Item [Qty] Cat. No.
DELTA-2000, 10 kV Automated Insulation Test Set Optional Accessories
120 Vac, 60 Hz 672001 Printer mounted in lid (in lieu of std. printer) Add -39
120 Vac, 50 Hz 672001-44 HV TTR capacitor (10 nF, 10 kV) 36610
240 Vac, 60 Hz 672001-45 HV reference capacitor (100 pF, 10 kV) 36610-1
240 Vac, 50 Hz 672001-47 HV reference capacitor (1000 pF, 10 kV) 36610-2
Included Accessories Carry case for capacitors 36610-CC
High voltage lead: 70 ft (21.4 m), double shielded, Capacitor kit (TTR cap, 2 ref caps, carry case) 36610-KIT
interchangeable hook or clip termination 30012-5 Resonating inductor 670600
Low voltage leads: 70 ft (21.4 m), shielded Calibration standard 670500-1
Color-coded Red 25572-1 Oil test cell 670511
Color-coded Blue 25572-2 Hot collar belts [3] 670505
Ground lead: 15 ft (4.6 m) 4702-7 Bushing tap connectors [2] 670506
120 volt Power cord: [1] 8 ft (2.5 m) 17032-4 Transit cases for cables (heavy-duty, foam-padded) 218744
240 volt Power cord: [1] 8 ft (2.5 m) 17032-2 Transit cases for calibration standard
Safety hand switch, Interlock #1: 70 ft (21.4 m) 34460-021 (heavy-duty, foam-padded) 670635
Safety hand switch, Interlock #2: 8 ft (2.5 m) 34460-020 Bar code wand and software 34705
Interconnect cables: For connecting the control RS-232 cable 34675-1
and high voltage units, two 5 ft (1.5 m) 27978, 27979 High voltage lead, 25 ft (7.6 m) 30012-8
Foam transit case: two, foam padded, heavy-duty Accessory kit: mini bushing tap connectors [2],
cases for control and high voltage unit 35582 hot collar straps [3], temperature/humidity meter [1],
Programmed battery/line power serial thermal printer 33842 .75” bushing tap connector [1], 1” bushing tap
connector [1], “J” probe bushing tap connector [1],
AC 120 V adapter 33841-2
3-ft non-insulating shorting lead [3],
AC 230 V adapter 33841-3 6-ft non-insulating shorting lead [3] 670501
Data keys [2] 30603 Priority Access package D2K-P-ACCESS
Data key interface box, 120 volt 30606
Data key interface box, 240 volt 30606-1
Data key download software 35227
Instruction and application manual AVTM672001A

ISO STATEMENT
Registered to ISO 9001:2000 Cert. no. 10006.01
DELTA2000_DS_en_V13

Megger is a registered trademark


Item 4B
DELTA-3000
10 kV Automated Insulation Power Factor Test Set

DELTA-3000
10 kV Automated Insulation Power
Factor Test Set with “PowerDB OnBoard”
■ Integrated PowerDB software package
allows for automated control without the
use of a laptop
■ Extremely easy to use, without any
extensive hardware or software setup
■ Rugged, portable unit for field/shop use
and designed to work in high interference
switchyards of up to 765 kV
■ Built-in capability for storing, printing
and downloading test results
■ Optional HV reference capacitors
(100 pF, 1000 pF) with 2% dissipation
factor, and a 10 nF TTR capacitor
■ Optional Priority Access package offering
exclusive services/support

DESCRIPTION The test set is designed to provide a comprehensive AC


The DELTA-3000 is a fully automatic 10 kV insulation insulation diagnostic test. Measurements are performed
power factor test set designed for condition assessment of automatically by the DELTA-3000, and results are displayed
electrical insulation in high voltage apparatus, such as on a large graphical LCD. Measured quantities include
transformers, bushings, circuit breakers, cables, lightning voltage, current, power (loss), power factor and
arresters and rotating machinery. Its integrated PowerDB capacitance. The operator has the option of correcting the
software package allows the user easy accessibility to the current and loss readings to their 2.5 kV or 10 kV
field without having to carry a laptop. equivalents. Information can be downloaded directly to a
PC or printer. An optional 10 nF TTR capacitor in addition
The DELTA-3000 allows for direct data feed into PowerDB
to two HV reference capacitors are also available.
for automatically generating test reports such as table of
contents, data sheets, deficiency and comments reports. All The built-in tracking automatic interference suppression
data can be saved in an XML file with all historical data. circuit ensures accurate and reliable test results under
This allows the user to view the previous year’s test sheet severe electrostatic and electromagnetic interference
or to trend specific test points. If a user also has a full conditions. This feature allows the performance of test
license of PowerDB, test sheets can be modified and measurements in energized switchyards of up to 765 kV.
downloaded to the instrument to customize the
In addition to performing insulation power factor tests, the
instrument’s personality and procedures in order to meet
DELTA-3000 can be used for measuring the excitation
customer needs.
current of transformer windings.
The unit’s intuitive and easy-to-use interface allows the
The Priority Access program provides specific guaranteed
user to configure test sheets and pop-up test procedures. A
support to assure full utilization of the Megger
QWERTY keyboard makes it simple for entering all
DELTA-3000. The purchase of the program entitles the user
nameplate and location information. USB drive support is
free services for one year from receipt of the unit.
also included in the unit with two exposed USB ports.
DELTA-3000
10 kV Automated Insulation Power Factor Test Set

FEATURES AND BENEFITS ■ The operator has the option of measuring either the
■ “PowerDB OnBoard” software allows for automated power factor or dissipation factor (tan ∂).
control and the option of saving data (information ■ Open-ground detector ensures proper grounding before
processing, data trending, report generation) in an
test.
XML file with all historical data.
■ Interlock switches provide operator safety.
■ QWERTY keyboard for quick information input.
■ Built-in interface to the optional Resonating Inductor
■ USB drive support for data download.
(Cat. No. 670600) to extend the capacitance measuring
■ Fully automatic operation eliminates operator error and range to 1µF at 10 kV.
reduces testing time. ■ Optional TTR capacitor (10 nF) in addition to two HV
■ Simplified operation procedure eliminates the need for reference capacitors (100 pF and 1000 pF) with a 2%
extensive software or hardware setups. dissipation factor.
■ Performs all standard ungrounded-specimen tests (UST) ■ Optional USB bar code scanner to record and
and grounded-specimen tests (GST), with or without a alphanumeric test identification in the field.
guard circuit. ■ Optional Priority Access package with exclusive services.
■ Utilizing the automatic suppression circuitry achieves ■ Optional Oil Test Cell for testing insulating fluids up
high accuracy measurement under severe electrostatic
to 10 kV.
and electromagnetic interference conditions.
■ Optional Calibration Standard verifies proper operation
■ Two-piece design reduces size and weight of the system
and accuracy of the test results.
and provides easier transportation.
■ Built-in self diagnostic and calibration check.

Close-up of DELTA-3000 panel

The DELTA-3000, available in either 120 or 240 V ac/50 or 60 Hz,


includes the Control Unit (top) and High Voltage Unit (bottom)
DELTA-3000
10 kV Automated Insulation Power Factor Test Set

SPECIFICATIONS Test Frequency


Same as line frequency
Input
120 V ±10%, 1 , 60 Hz, 1440 VA Interference Suppression
Available Suppression Methods
Output 1. Operator selectable automatic forward/reverse measurement
0 to 12 kV, continuously adjustable, 100 mA continuous, averaging.
maximum 200 mA (15 minutes on, 15 minutes off, maximum 8 2. Operator selectable automatic tracking interference cancellation.
tests). The power supply capacity can be expanded to 4 Amps
using the optional Resonating Inductor, catalog number 670600. Safety Qualifications
The test set meets the requirements of both the IEC-1010 and the
Accuracy CE mark specifications. The test set also meets the shock and
Voltage vibration requirements of the ASTM D999.75 standard.
(RMS) ±(1% of reading + 1 digit)
Environment
Current
Temperature
(RMS) ±(1% of reading + 1 digit)
Operating: 32 to 122° F ( 0 to 50° C),
Capacitance Storage: -58 to +140° F (-50 to +60° C)
±(0.5% of reading + 2 pF) in UST mode Relative Humidity
±(0.5% of reading + 6 pF) in GST mode Operating: 0 to 90% non-condensing
Measuring Ranges Storage: 0 to 95% non-condensing

Voltage Dimensions
250 V to 12 kV, 10 V resolution. Minimum recommended voltage Control Unit
is 500 V. 16 H x 22 W x 16 D in.
Current (406 H x 559 W x 406 D mm)
0 to 5 Amps, 1µA maximum resolution. The measurement can be High Voltage Unit
corrected to either 2.5 kV or 10 kV equivalents. 16 H x 22 W x 16 D in.
Capacitance (406 H x 559 W x 406 D mm)
1 pF to 1.1 µF, 0.01 pF maximum resolution.
Weight
Power Factor Control Unit: 74 lb (33kg)
0 to 90%, 0.01% max. resolution. High Voltage unit: 63 lb (29 kg)
Watt-loss Cables: 35 lb (16 kg)
0 to 2 kW, actual power, 0 to 100 kW when corrected to 10 kV
equivalent. 0.1 mW maximum resolution. The measurement can
be corrected to either 2.5 kV or 10 kV equivalents.
Power Factor
±(2% of reading + 0.05%)
Watt-loss
±(2% of reading + 1mW)
Measurement
The following seven test modes are available, using the blue and
red measuring leads, and can be selected by the operator:
UST: Ground Red, Measure Blue
UST: Ground Blue, Measure Red
UST: No Ground, Measure to both Red and Blue
GST: No Guard
GST: Guard Blue, Ground Red
GST: Guard Red, Ground Blue
GST: Guard Red, and Blue, No Grounding
UST: Ungrounded Specimen Testing
GST: Grounded Specimen Testing
DELTA-3000
10 kV Automated Insulation Power Factor Test Set

OPTIONAL ACCESSORIES

Optional capacitor kit includes carry case, TTR capacitor (left), and
2 reference capacitors (center). Also shown are 2 connectors (right) that The optional Resonating Inductor expands the capacitance range
will work with the capacitors and are supplied with the DELTA-3000 unit of the DELTA-3000

The optional accessory kit, C/N 670501 includes mini bushing tap
connectors, hot collar straps, temperature/humidity meter, .75” bushing
tap connector, 1” bushing tap connector, “J” probe bushing tap
connector, 3-ft non-insulating shorting leads, 6-ft non-insulating
shorting leads

The optional Oil Test Cell, C/N 670511, is used for testing insulating
fluids up to 10 kV

The optional Calibration


Standard traceable to the
NIST for quick operating or
calibration checks of test set
bridges calibrated in watts
loss or in dissipation factor
DELTA-3000
10 kV Automated Insulation Power Factor Test Set

PowerDB™ Acceptance & Maintenance Test Data date, sales contact, and invoice information. Job
Management Software information can be transferred between field-use databases
The “PowerDB OnBoard” logo means PowerDB software and a master database. Job/Device Productivity Reports
is running on a computer embedded within the aid in bidding future jobs as well as personnel evaluation.
instrument. This gives the interface for new Megger
Electrical utilities who have invested in sophisticated
instruments a common “look and feel.” The instrument has
Computerized Maintenance Management Systems (CMMS)
a full QWERTY keyboard for entering nameplate, location
can easily link with the PowerDB software because it
information, test configuration and annotation.
works with a number of systems.
The user interface is intuitive and the printed results match
The package also provides a number of other optional
the format of these screens. (What you see is what you
add-ons that are described in the PowerDB data sheet
get.) The software maintains a history of results for each
available on the Megger website www.megger.com.
piece of equipment tests so past results can be displayed
in trend charts. Data is stored in an open format XML data
file. These files can be opened on a PC with PowerDB Lite
to view or print the test results.
Multiple data files can automatically be fed to a full
version of PowerDB in order to generate documentation
with a table of contents, test data sheets, comment and
deficiency summaries. PowerDB can also be used to
customize the test sheets and configuration screens used
by the instruments.
The DELTA-3000 is controlled and automated by the
PowerDB management system, a powerful software
package providing data management for acceptance and
maintenance testing jobs. Customer/contract information is
quickly sorted and searched. Opening a specific record
shows detailed information such as type of service, order

Data entry and automated control of Megger DELTA-3000


DELTA-3000
10 kV Automated Insulation Power Factor Test Set

ORDERING INFORMATION
Item [Qty] Cat. No. Item [Qty] Cat. No.
DELTA-3000, 10 kV Automated Insulation Optional Accessories
Power Factor Test Set with “Power DB Onboard” HV TTR capacitor (10 nF, 10 kV) 36610
120 Vac, 60 Hz 673001 HV reference capacitor (100 pF, 10 kV) 36610-1
120 Vac, 50 Hz 673001-44 HV reference capacitor (1000 pF, 10 kV) 36610-2
240 Vac, 60 Hz 673001-45 Carry case for capacitors 36610-CC
240 Vac, 50 Hz 673001-47 Capacitor kit (TTR cap, 2 ref caps, carry case) 36610-KIT
Included Accessories Resonating inductor 670600
High voltage lead: 70 ft (21.4 m), double shielded, Calibration standard 670500-1
interchangeable hook or clip termination 30012-5 Oil test cell 670511
Low voltage leads: 70 ft (21.4 m), shielded Hot collar belts [3] 670505
Color-coded Red 25572-1 Bushing tap connectors [2] 670506
Color-coded Blue 25572-2 Transit cases for cables (heavy-duty, foam-padded) 218744
Ground lead: 15 ft (4.6 m) 4702-7 Transit cases for calibration standard
120 volt Power cord: [1] 8 ft (2.5 m) 17032-4 (heavy-duty, foam-padded) 670635
240 volt Power cord: [1] 8 ft (2.5 m) 17032-2 Bar code scanner 36528
Safety hand switch, Interlock #1: 70 ft (21.4 m) 34460-021 High voltage lead, 25 ft (7.6 m) 30012-8
Safety hand switch, Interlock #2: 8 ft (2.5 m) 34460-020 Accessory kit: mini bushing tap connectors [2],
Interconnect cables: For connecting the control hot collar straps [3], temperature/humidity meter [1],
and high voltage units, two 5 ft (1.5 m) 27978, 27979 .75” bushing tap connector [1], 1” bushing tap
connector [1], “J” probe bushing tap connector [1],
Foam transit case: two, foam padded, heavy-duty
3-ft non-insulating shorting lead [3],
cases for control and high voltage unit 35582
6-ft non-insulating shorting lead [3] 670501
AC 120 V adapter 33841-2
Priority Access package D2K-P-ACCESS
AC 230 V adapter 33841-3
Instruction and application manual AVTM673001

Registered to ISO 9001:2000 Cert. no. 10006.01


5.CT / PT & Meter Testing
Item 5A
MCTT-10
Current Transformer Tester

MCTT-10
Current Transformer Tester

■ Performs saturation and ratio tests on CTs


using the voltage-comparison method
■ Tests bushing CTs mounted inside
transformers or switchgear
■ Eliminates the need for large Primary
Injection Test Systems to test CT
saturation and ratio
■ Saturation and ratio tests performed
without changing test lead connections
■ Overload and short-circuit protection

DESCRIPTION Ratio Test


The MCTT-10 test set is a portable unit for performing The ratio test is performed by comparing a voltage applied
saturation and ratio tests on current transformers using the to the secondary winding to the resulting voltage
voltage-comparison method. Model MCTT-10 provides a produced on the primary winding. For example, if 1 volt
variable voltage output and precision instrumentation for per turn is applied to the secondary winding, the voltage
testing single and multi-ratio CTs. All tests, saturation and present on the primary winding will be 1 volt. More
ratio – can be performed without changing any leads. specifically, if 120 volts were applied to the secondary of a
Current transformers can be tested in their equipment 600/5 current transformer (120:1 ratio), 1 volt will be
configuration, such as being mounted in transformers, oil present on the primary winding.
circuit breakers or switchgear. It is necessary for the
equipment to be totally isolated from the electrical system
FEATURES AND BENEFITS
prior to testing. ■ The MCTT-10 utilizes the voltage comparison method.

Saturation and ratio tests are critical to ensure proper This provides the user wth the ability to measure the CT
electrical system reliability. Saturation tests are performed ratio without the heavy and large equipment needed to
on CT’s to make sure that when a fault occurs the proper test a CT ratio using the current method. Many of the
secondary current signals are delivered to the protective devices using the current-comparison method exceed
devices. If a CT does not deliver proper secondary 100 lbs (45 kg). The MCTT-10 is only 37 lbs (16.8 kg).
current signals to a protective device because of core ■ A RUN/HOLD switch freezes readings on instruments
saturation, it is probable that the protection scheme will
when switched to the HOLD position. This permits the
not operate correctly. A CT ratio test is performed to
user to freeze all the MCTT-10 meters for simultaneous
ensure that the secondary current signals are proportional
readings.
and correct, in relation to the primary current.
■ A low range of 40 volts is provided for CTs that saturate
at low voltages. A low voltage output range permits the
APPLICATIONS
MCTT-10 to test low saturation CT’s with the appropriate
Saturation Test resolution.
MCTT-10 provides a variable voltage output and digital
■ The unit provides a high range of 1000 volts. This
instrumentation for measuring the excitation voltage and
excitation current, that results as the voltage applied to the allows the MCTT-10 to test nearly all protection CT’s
CT under test is increased. As the CT under test begins to with high saturation knee points.
saturate, a large increase in current will be detected for a ■ A zero-start interlock is incorporated in the unit. This
small increase in voltage. minimizes the possibility of energizing the CT test with a
sudden high voltage, while under test.
MCTT-10
Current Transformer Tester

SPECIFICATIONS
Input
115 V +10/-5%, 1 q, 50/60 Hz OR 230 V +10/-5%, 1 q, 50/60 Hz
Output
BUSHING CT'S
Continuously variable in four ranges:
0 to 40 V at 1.5 A max
0 to 150 V at 1.5 A max H1 DISPLAY
MAIN CB

MCTT-10
! HOLD

0 to 600 V at 1.5 A max


RUN
CURRENT TRANSFORMER TESTER
H2

0 to 1000 V at 1.0 A max (5 min on, 15 min off) X1


THERMAL O/I

OUTPUT RANGE
150 600
X2 H VOLTS

Instrumentation 40

OFF
1000
100
0
FINE VOLTAGE CONTROL

ON
X1-X5
Voltmeters X VOLTS

Two 4 1/2 digit, auto ranging OFF


POWER

Solid-state Instruments X AMPERES


0
MAIN VOLTAGE CONTROL
100

Ranges: 0.0000 to 1.9999/19.999/199.99/1000 V


Accuracy: ±0.25% of reading, ±1 digit for 1 to 1000 V;
±1% of reading ±1 digit for 0.2 to 1 V Connections for performing saturation, ratio and polarity tests

Ammeter
One 41/2 digit
Solid-state Instrument
Range: 0.0000 to 1.9999 A
Accuracy: ±0.85% of reading, ±1 digit
Enclosure
The unit is housed in a high-strength, molded suitcase-type
enclosure with carrying handle and removable cover. Storage
space is provided for test leads.
Dimensions
9.9 H x 14.1 W x 11.9 D in.
(251 H x 357 W x 287 D mm)
Weight
37 lbs (16.8 kg)

ORDERING INFORMATION
Item (Qty) Cat. No.
Model MCTT-10
115 volt input 50/60 Hz MCTT-10-115
230 volt input 50/60 Hz MCTT-10-230
Included Accessories
Test Leads
Lead, Red, 200cm CAT III (2 qty) 684022
Lead, Black, 200cm CATIII (2 qty) 684023
Alligator Clip, Red, CATIII (2 qty) 684006
Alligator Clip, Black, CATIII (2 qty) 684007
Line Cord (1 qty) Model MCTT-10-115 6828
Line Cord (1 qty) Model MCTT-10-230 15065
Instruction Manual 710019
Technical Specifications
Current transformers
Nominal currents of the CT to be tested (X) 5 A and 1 A
Nominal Current of the standard CT (N)v 5A
Working range 1 ... 200% of nominal current
Frequency 50 and 60 Hz
Uncertainty of ratio measurement r 100 ppm r 3% of reading
Uncertainty of phase measurement r 100 Prad r 3% of reading
Inherent burden N-Side 0.1:
Inherent burden X-Side 50m:/5A , 0.55:/1A
Potential transformers
Nominal voltage of the PT to be tested (X) 40 ... 140 V with factors 1, ½, 1/3, 1/— 3
Nominal voltage of the standard PT (N) 100 V
Working range 1 ... 200% of nominal voltage
Frequency 50 and 60 Hz
Uncertainty of ratio measurement ± 100 ppm ± 3% of reading
Uncertainty of phase measurement ± 100 mrad ± 3% of reading
Inherent burden of X- and N-Side 25 k:(0.4 VA/ at 100V)
Electronic current transformers
Nominal voltage of the CT to be tested (X) 400 mV ... 4 V
Nominal Current of the standard CT (N)v 5A
Working range 1 ... 200% of nominal current
Frequency 50 and 60 Hz
Uncertainty of ratio measurement r 200 ppm r 3% of reading
Uncertainty of phase measurement r 200 Prad r 3% of reading
Inherent burden N-Side 0.1 :
Inherent burden X-Side 1M:
Electronic voltage transformers
Nominal voltage of the standard PT (N) 100 V
Nominal voltage of the PT to be tested (X) 1 ... 8V with factors 1, ½, 1/3, 1/— 3
Working range 1 ... 200% of nominal voltage
Frequency 50 und 60 Hz
Uncertainty of ratio measurement r 200 ppm r 3% of reading
Uncertainty of phase measurement r 200 Prad r 3% of reading
Inherent burden N-Side 25 k: (0.4 VA/ at 100V)
Inherent burden X-Side 1 M:

Reference conditions
temperature 23° C ± 2°
humidity 45 ... 75%
altitude (pressure) 101.3 kPa

Rated range of use


according IEC 359
temperature 5° C ... 40° C
humidity, non condensing 20 ... 95%
altitude (pressure) 70 ... 106 kPa

Dimensions (W, D, H) 500 x 360 x 192 mm


Weight 15 kg
Power mains 230V/50 Hz 50 VA
Measuring cables
For Current Transformers 20m (2 pcs.)
For voltage transformers 20m (2 pcs., twisted)
Item 5B
MCT1600
Current Transformer Saturation, Ratio and Polarity Test Set

MCT1600
Current Transformer Saturation,
Ratio and Polarity Test Set
I One button automated test:
Demagnetization, CT Ratio, Knee Point,
Saturation, Polarity and Phase Deviation Test
I Displays multiple instantaneous Saturation
Curves with Knee Point
I Integrated 1 kV DC insulation test system
I Color daylight viewable graphical display
I “Save & Print Later” with USB stick
I Fast data entry using full QWERTY keyboard
I 1600 VAC Saturation Test Voltage
I Automatic or manual testing selectable

DESCRIPTION CT’s include a multi-ratio secondary, therefore the


The Megger MCT1600 test set is a lightweight, robust, MCT1600 has the ability to plot and simultaneously
portable unit used to automatically or manually perform display up to 10 CT saturation curves.
saturation, ratio, polarity, demagnetizing tests and
insulation tests on current transformers. The MCT provides Ratio Test
a microprocessor controlled variable voltage output and Ratio testing is performed by comparing a voltage applied
precision instrumentation for automatically testing single to the secondary winding to the resulting voltage
and multi-ratio CTs. The MCT1600 possesses produced on the primary winding. For example, if 1 volt
microprocessor controlled output voltage with precision per turn is applied to the secondary winding, the voltage
instrumentation and storage, reducing testing time and
increasing productivity. All three tests – saturation, ratio
and polarity – can be performed with the push of a button
and without changing leads. The MCT1600 has a large
display, permitting the user to easily read all pertinent data
while the test is being performed and providing the ability
to view the current transformer’s saturation curve.
Current transformers can be tested in their equipment
configuration, such as being mounted in transformers,
oil circuit breakers or switchgear. It is necessary for the
equipment to be completely isolated from the electrical
system prior to testing.

APPLICATIONS
Saturation Test
With the single push of a button, The MCT1600 performs
a CT saturation test and calculates the rated knee point.
The saturation test is performed at mains rated frequency
of 50 or 60 Hz as required by IEC regulations. The
MCT1600 will calulate the rated knee point in compliance
with IEEE C57.13.1, IEC 60044-1 or IEC 60044-6. While
the saturation test is being performed, The MCT will plot
the CT saturation curve on the large graphical display and
automatically provide the user with the rated knee point
per the desired IEEE or IEC standard. Many substation
MCT1600
Current Transformer Saturation, Ratio and Polarity Test Set

Data Storage and Printing


The MCT1600 test system not only permits accurate and
The Megger MCT1600 is
automated CT testing, but also catalogues and stores test
easily field transportable results within the instrument for simple retrieval by
along with an software at a later date. All catalogued test results can be
accompanying heavy
duty carry bag for leads uploaded to Megger’s PowerDBTM Lite for report generation
and cords. and saturation curve plotting on a computer. PowerDB
Lite also has the ability to operate the MCT1600 with no
operator intervention, thus providing a completely
computer controlled automated test system.

present on the primary winding would be 1 volt. More


specifically, if 120 volts were applied to the secondary of a
600/5 current transformer (120:1 ratio), 1 volt would be
present on the primary winding. This test is performed
automatically during a CT saturation test or manually with
the output control knob and metering display. The
MCT1600 will also provide the operator with a direct
reading ratio, thus removing the need to calculate CT
ratio manually.

Polarity Test
Polarity of the current transformer under test is indicated to
the operator by a simple “Correct” or “Incorrect” indication
on the display accompanied by the measured phase angle.

Demagnetization
Normal operating conditions and typical winding resistance
measurements can cause a CT to become magnetized.
The MCT1600 has the ability to automatically demagnetize
Complete report generation with PowerDb Lite
the CT under test. This automatic demagnetization routine
is useful to ensure that the CT Saturation test yield correct
results. Prior to testing demagnification is recommended The operator also has the option to print any catalogued
per ANSI C57.13.1. test results immediately using an optional printer,
providing hard copy of test reports immediately upon CT
Insulation Resistance Test
test completion.
In order to ensure that the CT secondary wiring is properly
insulated, the MCT1600 system includes a 500/1000V Onboard memory allows complete test results and data to
insulation resistance test system. This test ensures that the be stored in one complete file, permitting easy access to
CT secondary winding and secondary wiring is properly quick construction of reports such as saturation curve with
insulated per ANSI C57.13.1. knee point. The MCT1600 test file is saved in a Microsoft
XML format, thus the data is available to any application
Note: Disconnect all electronic loads before performing
that will accept an XML format.
this test.
Upgradeability
The MCT1600 includes the ability to upgrade the user
interface and testing capability using updates supplied on
a USB memory device and a simple “upgrade” command.
This upgrade capability permits the MCT1600 system to
improve as new testing needs are developed.
MCT1600
Current Transformer Saturation, Ratio and Polarity Test Set

With a manual
voltage output
control knob, the
user is able to
perform any test
required manually
if only a spot
check is required.

Saturation Curve and all test results displayed at a glance.

FEATURES AND BENEFITS


I Large Display - The large graphical display provides the
user with immediate. easy to read test results including a
plot of the CT saturation curve. This display also
provides the user with simple, easy to read test results
for Ratio and Polarity Test.
I CT Saturation, Ratio and Polarity Automated Testing -
The microprocessor-controlled output fully automates
Manual testing screen.
testing of CT’s. This automated testing simplifies CT
testing and reduces testing time. Automated testing is I Test Result Report - The MCT1600 offers storage of
accomplished directly on the MCT1600 or via the complete test files in an easy-to-use, versatile format that
included MS Excel macro. permits upload to PowerDB Lite, or printing test results
I CT Demagnetization - During operation and routine DC using the optional external printer. These options
winding resistance testing, it is possible for a CT to provide a simple, complete, easy way to store over 200
become magnetized. The MCT1600 includes an test results and saturation curves. All test results can be
automated CT Demagnetization function, which allows catalogued and stored in
determination of accurate Knee Point as well as stable, the MCT1600.
repeatable test results, and reduces test time. I High Voltage Warning
I Insulation Test - The MCT1600 includes a 500/1000V Indication - The MCT1600
insulation test system to verify the CT secondary winding can produce a high voltage
and secondary wiring. This insures that the secondary output. To ensure the
insulation has not degraded and will continue to perform safety of the user, a high
its function during high current faults. voltage warning is issued
via both the MCT1600 and
I Complete CT Testing - The MCT1600 system provides the PowerDB Lite interface
a complete CT saturation, ratio and polarity test. prior to the presence of any
Eliminating the need for multiple pieces of test output test voltage.
equipment to perform a CT test. All test are performed
I Manual Operation - The Download test results to a USB device.
in compliance with IEEE C57.13.1 test guidelines.
MCT1600 is also supplied
I Full QWERTY Keyboard - The field ruggedized full with a manual voltage output control knob. This
QWERTY keyboard simplifies nameplate data input. permits the user to perform any test required manually
if only a spot check is required. This allows the user to
ensure that test results are correct, assisting in diagnosis
of a faulty CT.
MCT1600
Current Transformer Saturation, Ratio and Polarity Test Set

SPECIFICATIONS Ratio
Range Accuracy
Input 0.8 to 5000 ±0.4% typical
100 to 265 V, 1ø, 50 or 60 Hz, 15 A max. ±0.8% maximum

Output Insulation Test


Test Voltage: 1000 VDC, 500 VDC
Continuously variable in six ranges:
Measuring Range: 10kΩ – 999MΩ
0 to 40 V at 2.0 A max (1 minute on 15 minute off)
Short Circuit Current: 1.5mA nominal
0 to 160 V at 2.0 A max (1 minute on 15 minute off)
Test Current on Load: 1mA at min. pass values of insulation
0 to 800 V at 1.5 A max (3 min on, 15 min off)
(as specified in BS7671, HD 384 and IEC 364)
0 to 1600 V at 1.0 A max (3 min on, 15 min off)
Accuracy: ±3%, ±2 digits up to 10MΩ
Instrumentation ±5%, up to 100MΩ
±30% up to full scale
Voltmeters
Output Communication Interfaces
41⁄2 digit, auto ranging USB
Resolution: 0.0000 to 1.9999/19.999/199.99/1999.9 Ethernet
Ranges: 0 to 40/160/800/1600 V Environment
Accuracy: ±0.5% of reading, and ±.5% range typical Operating: -10º C to 40º C
±1% of reading and ±1 V maximum Storage: -30º C to 70º C
Input
Enclosure
41⁄2 digit, auto-ranging
The unit is housed in a rugged enclosure suitable for use in
Ranges: 0 to 2/600
outdoor substations.
Resolution: 0.0000 to 1.9999/1.99/1.9/600 V
Accuracy Standards
2 V Range: ±0.5% of reading and ±0.25% range IEC 61010
600 V Range: ±0.5% of reading and ±0.5% range CSA 22.2
CE
Ammeter
41⁄2 digit Dimensions
Range: 0.0000 to 1.0000A/5.000 7.5” H X 19.25” W X 15” D
Accuracy: ±0.85% of reading and ±1 LSD (190 H X 489 W X 940 D mm)

Phase Angle Weight


47.6 lb (21.6 kg)
3 digits
Range: 0 to 360 degrees
Accuracy: ±1 degree

ORDERING INFORMATION
Item (Qty) Cat. No. Item (Qty) Cat. No.
MCT1600 Current Transformer Saturation, Alligator clip, red, 4.1 mm, (1 ea) 684006
Ratio and Polarity Test Set MCT1600 Alligator clip, black, 4.1mm, (1 ea) 684007
Included Accessories Soft side lead case 684035
Line cord, North American (1 ea) 620000 USB memory stick 830029
Line cord, International color coded wire (1 ea) 15065 Ethernet crossover cable (1 ea) 620094
Test lead, H1 & H2, 40 ft, (1 ea) 620148 Instruction book 750025
Test lead, X black, 20 ft, (1 ea) 620149 PowerDB Lite 544342
Test lead, X red, 20 ft, (1 ea) 620150
Optional Accessories
Ground lead, green with yellow,
Printer USB, battery operated, (1 ea) 830030
with large ground clip, 20 ft, (1 ea) 620151
PowerDB, 1 copy with USB key
st
DB1001S
Large test clip, red, 40mm opening, (1 ea) 640266
Large test clip, black, 40mm opening, (1 ea) 640267
Item 5C
PTT 2.1
Portable Instrument Transformer Tester

The PTT 2.1 is an easy and light in weight test in- • Small dimensions and light in weight
strument for testing instrument transformer using the • Serial interface for data transfer (RS 232)
existing load of the installation.
Applications
Advantages
• On-site ratio test of current instrument trans-
• Burden measurements of current instrument former
transformer (CT) and voltage instrument trans-
former (PT) inclusive input of wiring parameters • On-site burden test of current instrument trans-
e.g. cable lengths, cable diameter, resistance of former
fuses and junctions, in case that the measure- • On-site burden test of voltage instrument trans-
ment is not carried out directly on the CT termi- former
nals.
Options
• Current instrument transformer ratio measure-
• CALSOFT I read out software for transfer and
ments based on a simultaneous primary and
presentation of data
secondary current measurement
• Data memory for 680 complete data sets
• Printer DATAMEGA
Technical Data PTT 2.1
Auxiliary supply: 46 V ... 300 V Influence of external ≤ 0.25 % / 0.5 mT
(Max. Voltage without de- magnetic fields:
struction: 480 V / t ≤ 30s) Safety requirements
Power consumption: ≤ 10 VA CE- certified
Housing: Hard plastic Isolation protection: EN 61010-1
Dimensions: W 125 x H 236 x D 41 mm Degree of protection: IP-55
Weight: ca. 650 g Storage temperature: - 20 ... + 60°C
Operation temperature: -10 °C ... +50 °C Relative humidity: ≤ 85% at Ta ≤ 21°C
Temperature coefficient: 0.02 % / K +0 ... +40°C Relative humidity for 30 ≤ 95% at Ta ≤ 25°C
0.05 % / K -10 ... +50°C days/year spread:
Frequency range: 45 ... 66 Hz
Measurement accuracy
Tolerance = ± ≤ indicated value of accuracy E(%) / phase shift ∆ϕ(°), Ecos
CT ratio: Accuracy E(%) of ratio error Ei, Et / Phase shift ∆ϕ(°) of phase displacement ϕp, ϕs
IN1: Ip CT 100A CT 1000A LEMflex 3000A
IN2: Is CT ratio > 500 mA … 100 A > 5 A … ≤ 50 A > 50 A … 1000 A 3 A … 3000 A
I (12A) > 10 mA … ≤ 12 A 0.4 % / 0.3 ° 0.7 % / 0.4 ° 0.7 % / 0.3 ° 0.7 % + ECT / ---
CT 100A > 500 mA … 100 A 0.4 % / 0.3 ° (1) 0.7 % / 0.4 ° 0.7 % / 0.3 ° 0.7 % + ECT / ---
(1) Second CT 100A necessary (option)
CT, PT burden: Accuracy E(%) of operating burden Sb / Phase shift ∆ϕ(°) of burden phase angle β
IN1: U U (300V)
IN2: I CT burden 20 mV … ≤ 100 mV > 100 mV … ≤ 30 V
I (12A) > 10 mA … ≤ 12 A (0.2 + 0.5)% / 0.3 ° 0.7 % / 0.3 °
CT 100A > 50 mA … ≤ 500 mA (0.5 + 0.5)% / 1.6 ° 1 % / 1.6 °
> 500 mA … 100 A (0.2 + 0.5)% / 0.3 ° 0.7 % / 0.3 °
Accuracy Ecos of burden factor cos
IN1: U U (300V) Ecos (∆ϕ, cos)
IN2: I PT burden >30 V … 300 V ∆ϕ ±(0.8 … 1) ±(0.5 … 0.8)
I (12A) 1 mA … ≤ 10 mA (0.2 + 0.2)% / 0.6 ° 0.3° 0.4 % 0.9 %
> 10 mA … ≤ 12 A 0.4 % / 0.3 ° 0.6° 0.8 % 1.8 %
CT 100A 10 mA … ≤ 50 mA (0.5 + 0.2)% / 2.6 ° 1.6° 2.1 % 4.9 %
> 50 mA … ≤ 500 mA 0.7 % / 1.6 ° 2.6° 3.5 % 8.0 %
Current, voltage: Accuracy E(%) / Phase shift ∆ϕ(°) of I,U
I 1 mA … ≤ 10 mA > 10 mA … ≤ 12 A
I (12 A) (IN2) 0.2 % / 0.5 ° 0.2 % / 0.15 °
10 mA … ≤ 50 mA > 50 mA … ≤ 500 mA > 500 mA … 100 A
CT 100A (IN1, IN2) 0.5 % / 2.5 ° 0.5 % / 1.5 ° 0.2 % / 0.15 °
1A…≤5A > 5 A … ≤ 50 A > 50 A … 1000 A
CT 1000A (IN1) 0.5 % / 1.5 ° 0.5 % / 0.25 ° 0.5 % / 0.15 °
3 A … 30 A 30 A … 300 A 300 A … 3000 A
LEMflex 3000A (IN1) 0.5 % + ECT / --- 0.5 % + ECT / --- 0.5 % + ECT / ---
> 2 A … 2000 A ECT : Accuracy specification of CT manufacturer
AmpLiteWire 2000A (IN1) 0.5 % + ECT / --- --- : No specification for phase shift

U 20 mV … ≤ 100 mV > 100 mV … ≤ 30 V >30 V … 300 V


U (300V) (IN1) 0.5 % / 0.15 ° 0.5 % / 0.15 ° 0.2 % / 0.15 °

0.5 %: Tolerance related to measurement range final value (Full Scale, FS). Tolerance depends from measurement value
(M): E(%) = FS / M *x.x %, e.g. 0.5 %, 20 mV … ≤ 100 mV, U = 50 mV; E(%) = 100mV / 50mV*0.5 % = 1 %.
Formulas for accuracy specification of ratio and burden measurement
E(%), ∆ϕ(°) and Ecos are based on the specification of the used voltage and current ranges of used inputs IN1, IN2.
Accuracy E(%) for ratio / burden Phase shift ∆ϕ(°) for ratio / burden Accuracy Ecos of burden factor
E (ratio) = E(IN1 : Ip) + E(IN2 : Is) ∆ϕ (ratio) = ∆ϕ(IN1 : Ip) + ∆ϕ(IN2 : Is)
E (burden) = E(IN1 : U) + E(IN2 : I) ∆ϕ (burden) = ∆ϕ(IN1 : U) + ∆ϕ(IN2 : I)

Edition 05.2005
Item 5D
PWS 2.3 PLUS
Three-phase Portable Working Standard for Testing Electric-
ity Meters and Instrument Transformers

The PWS 2.3 PLUS Portable Working Standard is a three- Functions


phase portable electronic meter test unit, used for testing
single and three-phase electricity meters on site. The • Active, reactive and apparent energy measurement for
PWS2.3 PLUS allows checking of all meter installation single-phase and three-phase, 3- or 4-wire, circuits
parameters and associated circuits. The PWS 2.3 PLUS, with integrated error calculator
with integrated instrument transformer test functions, is • Impulse output for energy (galvanic isolated)
available in accuracy classes 0.1 or 0.2. • Registration of active, reactive and apparent energy for
register testing
The unit can be used either with a direct connection in the
• Active, reactive and apparent power measurements
range of 1 mA ... 12 A, or by using a set of 3 active 100A
• Current and voltage measurements
error compensated clamp-on CT’s (included in the stan-
dard accessories set) in the range 10 mA …100 A. It is • Power factor measurements
therefore possible to easily and accurately measure both • Frequency measurements
CT and direct connected meters. • Burden measurement of Current Transformer (CT) and
Potential Transformer (PT)
The unit can be powered either from the measuring circuit
• Ratio testing of Current Transformer (CT)
or from an auxiliary single-phase supply.
• Ratio testing of Potential Transformer (PT) (option)
Advantages
Options
• Precision test equipment for AC values in the 45 Hz to
66 Hz frequency range • Software CALSOFT
• Wide measuring range with auto ranging • Set of 3 clamp-on CT 10A (active error compensated)
• Display of vector diagram for analysis of mains condi- • Set of 3 clamp-on CT 1000A
tions and meter connections • Set of 3 flexible current probes LEMflex 30/300/3000A
• Measurements of wave forms and harmonics with dis- • 3-phase adapter for AmpLiteWire, VoltLiteWire
play • 1-phase adapter for AmpLiteWire, VoltLiteWire
• Easy detection of circuit connection faults • Primary current sensor AmpLiteWire 2000A
• Data memory for test results and customer data • Primary voltage sensor VoltLiteWire 40kV
• Small dimensions and light in weight
• Serial interface for data transfer (RS 232)
Meter data
Other
Customer checks data
data
Harmonics
analyses
Error
Vector measurement
diagram Register
tests

Administrative data set (ADS)

Meter testing and measurements


PT Burden
measurements
CT Burden
Ratio measurements
measurements

Clamps
up to 1000 A
Clamps
Clamps up to 3000 A
up to 100 A LiteWire
Sensors

Instrument transformer testing

Several optionally current clamps


Technical Data PWS 2.3 PLUS 125
CT Burden ≤ ± E [%]
General I (current direct I1) U (U1 - N) Cl. 0.1 Cl. 0.2
Auxiliary supply: Power may be taken from the auxiliary 10 mA … 12 A 100 mV … 5V 0.6 1.2
supply or the measuring circuit
at 46 V ... 300 V / 47 … 63 Hz 10 mA … 12 A 20 mV … 100 mV 0.1 + 0.5 0.2 + 1.0
Power consumption: max. 25 VA
Housing: Hard Plastic PT Burden ≤ ± E [%]
125

Dimensions: W 290 x H 216 x D 81 mm


(inclusive rubber protection) I (Current direct I1) U (U1 - N) Cl. 0.1 Cl. 0.2
Weight: approx. 2.2 kg (incl. rubber protection) 10 mA … 12 A 46 V … 300 V 0.2 0.4
Operation temperature: -10 °C ... +60 °C 1 mA … 10 mA 46 V … 300 V 0.1 + 0.1 0.2 + 0.2
Storage temperature: -20 °C ... +60 °C
Relative humidity: ≤ 85% at Ta ≤ 21°C 126
CT Ratio ≤ ± E [%] / ∆ϕ [°]
≤ 95% at Ta ≤ 25°C, 30 days / year spread
IP - Input / Range IS (I1, I2, I3) Cl. 0.1 Cl. 0.2
Safety CE certified Clamp-on CT 100A
Isolation protection: IEC 61010-1:2002 100 mA … 100 A 10 mA … 12 A 0.3 / 0.3 0.4 / 0.4
Measurement Category: 300V CAT III 100 mA … 100 A 1 mA … 10 mA 0.2 + 0.1 / - 0.2 + 0.2 / -
Degree of protection: IP-40 Clamp-on CT 1000A
Measurement Range 10 A …1000 A 10 mA … 12 A 0.3 / 0.3 0.4 / 0.4
1A … 10 A 10 mA … 12 A 1.0 / - 1.2 / -
Measuring Quantity Range Input / Sensor
LEMflex 3000A
Voltage (phase - neutral) 3V … 300 V U1, U2, U3, N
300 A …3000 A
20 mV … 5V U1, N (CT Burden)
30 A … 300 A 10 mA … 12 A 0.2 + EM / - 0.2 + EM / -
Current 1 mA … 12 A I1, I2, I3
3A … 30 A
1 mA … 10 A Clamp-on CT 10A
AmpLiteWire 2000A
10 mA … 100 A Clamp-on CT 100A
300 A …2000 A 10 mA … 12 A 0.2 + EM / - 0.4 + EM / -
100 mA …1000 A Clamp-on CT 1000A 30 A … 300 A 10 mA … 12 A 0.2+0.1+EM/ - 0.2+0.2+EM/ -
3A …3000 A LEMflex 3000A
Primary voltage 500 V … 40 kV VoltLiteWire 40kV PT Ratio ≤ ± E [%] / ∆ϕ [°] 1 2 6
Primary current 30 A …2000 A AmpLiteWire 2000A
UP (VoltLiteWire) US (U1, U2, U3, N) Cl. 0.1 Cl. 0.2
Measurement Accuracy 6 kV … 40 kV 46 V … 300 V 0.2 + EM / - 0.4 + EM / -
500 V … 6 kV 46 V … 300 V 0.1+0.1+EM/ - 0.1+0.2+EM/ -
Voltage / Current ≤ ± E [%] 1 2 4
Measuring Quantity Range Cl. 0.1 Cl. 0.2
Frequency / Phase Angle / Power Factor ≤±E
Voltage (U1, U2, U3, N) 46 V … 300 V 0.1 0.2
Measuring Quantity Range Cl. 0.1 Cl. 0.2
3V … 46 V 0.3 0.5
Frequency (f) 40 Hz … 70 Hz 0.01 Hz
Current direct (I1, I2, I3) 10 mA … 12 A 0.1 0.2
0.2
ϕ)
Phase Angle (ϕ 0.00 °… 359.99° 0.1 °
1 mA … 10 mA 0.1
Current clamp-on CT 10A 10 mA … 10 A 0.2 Power Factor (PF) -1.000 … +1.000 0.002

Current clamp-on CT 100A 100 mA … 100 A 0.2 Notes


1
x.x :Related to the measuring value
Current clamp-on CT 1000A 10 A …1000 A 0.2 x.x :Related to the measuring range final value (full scale, FS),
Current LEMflex 3000A 300 A …3000 A E(M) = FS/M * x.x (e.g. 0.1 at FS =10 mA, E(2mA) = 10/2 * 0.1 = 0.5 %)
2
30 A … 300 A 0.1 + EM 0.2 + EM Fundamental frequency in the range 45 … 66 Hz
3
3A … 30 A S: x.x, P,Q: x.x / PF (related to apparent power), 3- and 4-wire networks
4
EM: Accuracy specified by manufacturer of clamp-on CT or sensor
Burden Voltage (U1, N) 100 mV … 5 V 0.5 1.0 5
E[%]: Accuracy of operating burden Sn [VA]
20 mV … 100 mV 0.5 1.0 6
E[%]: Accuracy of ratio Ei, Et; ∆ϕ[°]: Phase shift of phase displacement
Current AmpLiteWire 2000A 300 A …2000 A 0.1 + EM 0.2 + EM ϕp, ϕs.
30 A … 300 A 0.1 + EM 0.2 + EM
Voltage VoltLiteWire 40kV 6 kV … 40 kV 0.1 + EM 0.2 + EM Pulse Input Suitable for scanning head type SH 2003
500 V … 6 kV 0.1 + EM 0.2 + EM Input level: 4 … 12 VDC (24 VDC)
Input frequency: max. 200 kHz
≤ ± E [%]
123 Input supply: 12 VDC (I < 60 mA)
Power / Energy Voltage: 46 V… 300 V (U - N)
Measuring quantity / Input I Range Cl. 0.1 Cl. 0.2 Pulse Output
Active (P), Apparent (S) Power / Energy Output level: 5V
Direct (I1, I2, I3) 10 mA … 12 A 0.1 0.2 Pulse length: ≥ 10µs
1 mA … 10 mA 0.1 0.2 Meter constant
Clamp-on CT100A 100 mA … 100 A 0.2 Active, Reactive, Apparent C = 40’000’000 / In
[imp/kWh(kvarh,kVAh)] The meter constant depends on the highest
10 mA … 100 mA 1.0
selected internal current range (In).
Reactive (Q) Power / Energy
Internal current ranges In [A]
Direct (I1, I2, I3) 10 mA … 12 A 0.2 0.4
Direct I1, I2, I3 0.012 0.12 1.2 12
1 mA … 10 mA 0.2 0.4
Clamp-on CT 100A 0.1 1 10 100
Clamp-on CT 100A 100 mA … 100 A 0.4
Example: Clamp-on CT 100A (In = 10 A)
10 mA … 100 mA 1.0
C = 40’000’000 / 10 = 4’000’000 [imp/kWh]
Output frequency: C’ = C / 3’600’000 [imp/Ws(vars, Vas)]
Influence of external magnetic ≤ 0.07 % / 0.5 mT 3 fo = C’ *PΣ(QΣ, SΣ)
fields (45 Hz … 66 Hz):
3
fmax = 40’000’000 / (10 * 3’600’000) *
≤ ± TC [%/°C] 3 * 10 * 300 = 10’000 [imp/s]
Temperature coefficient (TC): Range Cl. 0.1 Cl. 0.2
0° C ... +40°C 0.010 0.015
-10° C ... +60°C 0.015 0.025

Edition 04.2006
6.Computerised Power
Transformer Test Set
Item 6A
ETP System

ETP SYSTEM.
ETP: Basic features
Evaluation of Power Transformers
 Predictive Maintenance
 Less maintenance costs Condition Based Maintenance (CBM)
 Faults detection and
confirmation capability
 Each part of the
transformer is checked
 Easy to use
 Guided operation
 Automatic reports
generation
 Diagnostic and trending
software (optional;
coming soon)
 Maintenance contracts
and help on-line
 CE marked

Introduction
ETP System is a complete predictive The advantage provided by ETP System is
maintenance instrument for transformers, to allow a predictive maintenance
allowing us to detect the problems before philosophy, where corrective actions can
its unexpected appearance and to remove be programmed with enough time and in a
the high costs of urgent maintenance more efficient manner. This kind of
actions, transport and non-planned maintenance is being introduced in all
downtime. companies with big electrical machines.
The ETP System introduction produces a
The normal operation of a transformer can maintenance costs reduction.
be altered by several factors. Diagnostic
systems are based on the periodic ETP System makes several measurements
realization of tests that try to determine with the capacity of detect and confirm
when a problem can occur. These possible problems in each transformer's
problems can affect from an abnormal part:
way to some or several of transformer
components. Evaluation and diagnostic  Core
systems can be electrical or physical-  Windings Integrity
chemical. ETP System are based on  Liquid and solid insulation system
electrical test that can determine:  Internal windings position
 Liquid and solid condition  Regulator
 Electric circuit condition
 Magnetic Core condition
 Winding displacement

1/13
ETP
ETP System

ETP System is applicable to any kinds  Automatic three-phase winding


of transformers : resistance test with temperature
correction.
 Power transformers  Short circuit impedance.
 Distribution transformer
 Autotransformers In addition to the easy friendly use and
 Measurement transformer (only guided test, all results generated by ETP
voltage) System, as numeric values and graphics
 Single or three-phase. are automatically stored. When a test is
finished, a full report can be printed or
Each problem that can be detected in the saved so that it can be treated by two
transformers will come in many situations methods of evaluation:
indicated at least by two measurements,
making easier the decision process. ETP  Direct diagnostic, with the parameters
System carries out the following obtained at the finish of each test.
measurements:  Trend analysis to follow the evolution
of the parameters to determine if we
 Automatic three-phase turns ratio. are on a risky zone.
 Recovery voltage test/Insulation
Resistance test/Polarization Index.

Description
A variety of stresses occur during the the most of times it is impossible.
lifetime of transformers, arising from Anyway the first ETP test that you
mechanical, electrical, contamination perform will give you a complete
effects and lightning discharges in information about the transformer state
thunderstorms. Of among these, it is and therefor e the actions that you might
necessary to highlight the following ones: carry out on it, being a perfect start point
to monitoring the transformer ageing.
 Opening and closing of breakers
 Short circuit After this first test, if you test routinely
 Earth connection and keep records of the results generated
 Continuous overloads by ETP System, you can keep track of the
 Transie nt overloads condition of the transformer as it
deteriorates over time.
These lead to a number of different failure
modes with perhaps catastrophic results, The recommended time between test will
Quality of Service (QoS), economical and depend on the machine status: a very old
technical. or damaged machine must be tested in
shorter periods than a new or very good
Besides, as much the materials variety as status one. Repeating the test regularly for
the manufacturing process mediating on routine maintenance yearly may be
the complexity of transformers. appropriate if it is essential to keep the
apparatus in operation at all times. Testing
The ideal situation would be to do the first at one to four years intervals
test soon after the machine installation but may be sufficient for other

2/13
ETP
ETP System

applications. You should also test the European utility, over ten years using
transformer before and after a repair has results from testing over 10000
been performed on the equipment before transformers. Several utilities and services
it is re-energized. companies have adopted ETP System all
around the world.
Field experience and economics
Costs of unexpected failure, including
ETP System and its diagnostic criteria is repair and transportation of almost any
based on a theoretical principles and a kind of transformer easily justify ETP
great field testing experience. inversion.
ETP System was developed in
collaboration with Iberdrola, a major

ETP Method
It’s very important in order to make individual and compound values are
predictive maintenance that all tests will displayed at the same time corrected in
be comparative in time, removing all the temperature. This involves less time, not
mistakes caused by measuring instrument, only in test time so information
user, and environme nts factors. The processing and inform generating as well.
manage to make this, is using automatic
measure systems and closed tests, in Advantages of ETP System
which user hasn’t got any possibility of
chance and the measured values are  Predictive maintenance.
standardised automatically in external  Maintenance costs reduction.
factors like temperature.  Higher availability.
 High Reliability.
ETP System is very simple to use. A lot of  Ten years maturity.
measuring instruments failed in it’s own  Two measures for detection and
difficulty. All ETP measuring units are confirmation of each problem.
running in the same way, guiding the user  Speed measures without machine
in all testing and analysing process. danger.
 User friendly environment and guided
The ETP technique takes all operation.
measurements under Windows T M based  Eliminate human error.
PC control, which prompts the user during  Graphic and numeric data
test process including the correct visualization
connections to the transformer under test,  Modular equipment easy to carry.
so the testing is easy to carry out.  Values and data are saved and
organized automatically.
The best feature of this system comes in  Computer aided test control through
three-phase transformer with regulator due RS232 line and specific software.
to measuring test spe ed. In addition, the

3/13
ETP
ETP System

Information obtained These parameters are based in


theoretical principles and experienced
The ETP System measures several by qualified engineers for 10 years of
parameters that allow us to characterize testing and trending in more than 10000
a transformer. The anomalies in these transformers.
parameters or in their evolution could
be symptom of a failure. It is very The following table shows how ETP
important to perform a stage of tests System detects and confirms each
during the life of each transformer that possible damage on a transformer.
indicates us its evolution.

FAILURE DETECTED DAMAGE UM1B UM2B UM3B UM5B


CORE General ☺   
CONNECTION
Regulator breakdown ☺  ☺ 
Connection slackening   ☺ 
Windings displacement    ☺
Winding open loop. ☺  ☺ ☺
WINDINGS
INTEGRITY
Winding hot points   ☺ 
Short circuit among turns.   ☺ ☺
Winding partial short circuit ☺  ☺ ☺
Degradation of solid dielectric  ☺  
LIQUID AND Degradation of liquid dielectric
SOLID
 ☺  
INSULATION Contamination of the insulation  ☺  
Anomalous aging.  ☺  
Table 1: Equipment and detected damage.

☺ .- The problems of this type could be detected


 .- The problems of this type could be detected if they acquire certain significance.
 .- The problem could not be detected by way of this unit.

4/13
ETP
ETP System

ETP Equipment

5/13
ETP
ETP System

ETP System units can be classified in two mains (50 or 60 Hz): UM1B and UM5B.
groups, in function of the testing signal. On the other hand, UM2B and UM3B that
There are two equipments that make test make DC test.
with AC current to the frequency of the

UM1B: Transformer Turns Ratio Meter

The UM1B is a unit to measure the As voltage used is far from the
turns ratio of power and distribution transformer nominal voltage, this test is
transformers or autotransformers both totally non-destructive for the machine.
mono-phase and three-phase. With the turns ratio measurement it is
possible to detect problems in the
For measuring the turns ratio, the unit transformer like:
applies the voltage test to the high
voltage winding of the transformer and - Partial shorted turns.
measures the voltage induced in the low - Cut winding.
voltage winding. The equipment also - Regulator defect.
measures the excitation current and - Problem in magnetic core.
phase angle deviation between the
different magnitudes: V1, V2 and I1. The following graphs illustrate the main
features of UM1B equipment.

Testing with ETP System.

6/13
ETP
ETP System

Current and
voltage graphs.

Turns ratio graph.

Turns ratio table.

7/13
ETP
ETP System

UM2B: Recovery Voltage Meter

UM2B equipment is an automatic unit For the calculation of those parameters,


to take the following measurements in UM2B equipment applies different D.C.
power and distribution transformers or voltage levels through a programmable
autotransformers. source, taking values in an automatic
way at specified times. This test is
 Recovery Voltage and Time totally non-destructive for the machine
Constant that allows us to predict an and allows us to detect problems in the
anomalous ageing in the machine. transformer like:
 Insulation Resistance and
Polarization Index, that give us an  Degradation of solid dielectric
overview of insulation condition.  Degradation of liquid dielectric
 Contamination of the insulation

Recovery Voltage Graph.

Insulation
Resistance Graph.

8/13
ETP
ETP System

UM3B: Transformer Windings Resistance Tester

UM3B is a low resistance ohmmeter


specially designed for the resistance  Winding resistance on the three
measurement of transformers windings phases.
and single and/or three-phase  Resistance values corrected in
autotransformers of any variety. temperature.
 Calculations of individual and
In a single test, UM3B provides the compound resistance values ( or Y).
simple and compound resistance value for
each winding: both high and low voltage The measurement technique used is the
and tertiary. Furthermore, to calculate the metric ratio resistance method (measured
results, the system takes into account the on four wires). This technique presents a
transformer connection group, and the series of advantages, such as:
temperature at which the test is carried
out, as such results are provided at the  Immunity against the variations in the
reference temperature specified by the values of the measuring circuit
operator. components.
However this equipment is also suitable to  Immunity against temperature
pure ohmic resistance and windings changes.
resistance of rotating machine  Immunity against variations in test
measurements. current.
The UM3B unit permits to do the
following measurements automatically:

Winding Resistance Graph and Table.

9/13
ETP
ETP System

UM5B: Short Circuit Impedance Meter

UM5B measures the short circuit The main features of UM5B equipment
impedance of power and distribution are the following:
transformers or autotransformers applying
a voltage test to the high voltage winding  Automatic per-cent deviation
of the transformer and measuring the calculation between nameplate and
voltage excitation, the current excitation measurement short circuit voltage
and phase angle deviation between them: (Vcc).
V1 and I1. It’s carried out with the  Resistive and inductive
transformer LV winding in short circuit. components calculation of short
circuit impedance.
With the short circuit impedance  Signal graphic visualization for
measurement it is possible to detect voltage and current on high
problems in the transformer like: voltage winding.
 Optional 75ºC measurement
 Displacements between windings compensation.
 Open winding
 Partial shorted turns.

Current and Voltage Graph.

Current and Voltage Graph.

Short Circuit Parameters


Results Table.

10/13
ETP
ETP System

ETP System: Testing Procedure


One of the advantages of the system is Main Menu
the application software that facilitates
the complete evaluation of the Thanks to main menu, it is possible to
transformer in a short time and with access to the desired application to carry
reliable and traceable results. out a test, as well as to the diagnostic
and trends tools.

Main Menu.

Test's organization

The applications of every


equipment use a common test
data storage system. When a
test is started, some registers must
be filled in order to guarantee a
correct storage and following
identification.

Machine Identification.

11/13
ETP
ETP System

If the machine has just been tested process. Each application guides the
sometime, only the serial number would worker and assures that the test is always
be needed to restore all identification and made in the same way independently of
technical data, and to store the new test in the worker.
the same folder, making automatically the
machine’s historic log. In order to find Software shows during all process the
and observe the results, ETP System connections, precautions that the worker
carries out a search based on transformer's has to take and the actual state
serial number and test date. (measuring, printing, etc), being very
interactive with the worker.
Technical machine data scre en
ETP System carries out an automatic
ETP System stores all data in relation to measurement of different parameters and
the machine under test. This information displays the results clearly on the PC
is shared for all units and only has to be screen. Also, it generates a report of the
filled at the first made test. Application equipment tested. All technical data for
software will interpret these data in order the current and previous tests (perhaps
to guide the user in the connection of the over a period of years) are presented in a
device under test. structured manner. The clear presentation
of these reports makes interpretation of
Guided Menu the results straightforward and facilitates
predictive maintenance techniques
Software shows the operator a logical
flow of steps both in test and analysis

Test Search.

Technical data.

12/13
ETP
ETP System

Optional Tools
ETP DiagHelp automatically the diagnostic criteria
giving both the problem and its gravity.
In order to make diagnostic easier, ETP
DiagHelp makes a complete evaluation of ETP Trends
transformers using the diagnostic criteria
with the parameters and measurements ETP Trends tool has been developed to
made by ETP System. follow the evolution of the tested
machines by ETP System. The trend of a
The diagnostic criteria are based on parameter to change gives us information
theoretical principles and in the that something is wrong in the machine.
experience acquired by personnel of In these cases, it will be necessary to
Iberdrola and Unitronics during the la st 10 make more frequently test and correlate
years, with more than 10.000 rehearsals in them with ETP DiagHelp.
power transformers.
ETP Trends shows the results both in
This application recovers the file graphical and tabular format in order to
generated after the test applying easier evaluation.

13/13
ETP
7. Transformer Frequency
Response Analyzer
Item 7A
FRAX 101
Sweep Frequency Response Analyzer

FRAX 101
Sweep Frequency Response Analyzer
■ Smallest and most rugged FRA
instrument in the industry
■ Highest possible repeatability by
using reliable cable practice and
high-performance instrumentation
■ Fulfills all international standards
for SFRA measurements
■ Highest dynamic range and accuracy
in the industry
■ Wireless communication and battery
operated
■ Advanced analysis and decision support
built into the software
■ Imports data from other FRA test sets

DESCRIPTION
Power transformers are some of the most vital components
in today’s transmission and distribution infrastructure.
Transformer failures cost enormous amounts of money in
unexpected outages and unscheduled maintenance. It is
important to avoid these failures and make testing and
diagnostics reliable and efficient.
The FRAX 101 Sweep Frequency Response Analyzer
(SFRA) detects potential mechanical and electrical
problems that other methods are unable to detect. Major
utilities and service companies have used the FRA method
for more than a decade. The measurement is easy to
perform and will capture a unique “fingerprint” of the
transformer. The measurement is compared to a reference
“fingerprint” and gives a direct answer if the mechanical
parts of the transformer are unchanged or not. Deviations
indicate geometrical and/or electrical changes within the Collecting fingerprint data using Frequency Response Analysis (FRA) is an
easy way to detect electro-mechanical problems in power transformers
transformer. and an investment that will save time and money.

FRAX 101 detects problems such as:


APPLICATION
■ Winding deformations and displacements Power transformers are specified to withstand mechanical
■ Shorted turns and open windings forces from both transportation and in-service events, such
as faults and lightning. However, mechanical forces may
■ Loosened clamping structures exceed specified limits during severe incidents or when
■ Broken clamping structures the insulation’s mechanical strength has weakened due to
aging. A relatively quick test where the fingerprint
■ Core connection problems response is compared to a post event response allows for
■ Partial winding collapse a reliable decision on whether the transformer safely can
be put back into service or if further diagnostics is
■ Faulty core grounds required.
■ Core movements
■ Hoop buckling
FRAX 101
Sweep Frequency Response Analyzer

Method Basics Analysis and Software


A transformer consists of multiple capacitances, As a general guideline, shorted turns, magnetization and
inductances and resistors, a very complex circuit that other problems related to the core alter the shape of the
generates a unique fingerprint or signature when test curve in the lowest frequencies. Medium frequencies
signals are injected at discrete frequencies and responses represent axial or radial movements in the windings and
are plotted as a curve. high frequencies indicate problems involving the cables
from the windings, to bushings and tap changers.
Capacitance is affected by the distance between
conductors. Movements in the winding will consequently
affect capacitances and change
the shape of the curve.
The SFRA method is based on
comparisons between
measured curves where
variations are detected. One
SFRA test consists of multiple
sweeps and reveals if the
transformer’s mechanical or
electrical integrity has been
jeopardized.
Practical Application
In its standard application, a
“finger print” reference curve
for each winding is captured when the transformer is new An example of low, medium and high frequencies
or when it is in a known good condition. These curves can
later be used as reference during maintenance tests or
when there is reason to suspect a problem. The FRAX Software provides numerous features to allow
for efficient data analysis. Unlimited tests can be open at
The most reliable method is the time based comparison
the same time and the user has full control on which
where curves are compared over time on measurements
sweeps to compare. The response can be viewed in
from the same transformer. Another method utilizes type
traditional Magnitude vs. Frequency and/or Phase vs.
based comparisons between “sister transformers” with the
Frequency view. The user can also choose to present the
same design. Lastly, a construction based comparison can,
data in an Impedance or Admittance vs. Frequency view
under certain conditions, be used when comparing
for powerful analysis on certain transformer types.
measurements between windings in the same transformer.
These comparative tests can be performed 1) before and
after transportation, 2) after severe through faults 3) before
and after overhaul and 4) as diagnostic test if you suspect
potential problems. One SFRA test can detect winding
problems that requires multiple tests with different kinds of
test equipment or problems that cannot be detected with
other techniques at all. The SFRA test presents a quick and
cost effective way to assess if damages have occurred or if
the transformer can safely be energized again. If there is a
problem, the test result provides valuable information that
can be used as decision support when determining further
action.
Having a reference measurement on a mission critical
transformer when an incident has occurred is, therefore, a
valuable investment as it will allow for an easier and more
reliable analysis.
The figure above shows a single phase transformer after a service
overhaul where, by mistake, the core ground never got connected (red),
and after the core ground was properly connected (green). This potential
problem clearly showed up at frequencies between 1 kHz and 10 kHz and
a noticeable change is also visible in the 10 kHz - 200 kHz range.
FRAX 101
Sweep Frequency Response Analyzer

Test Object Browser — Unlimited number Quick Select Tabs — Quickly change Quick Graph Buttons — Programmable
of tests and sweeps. Full user control. presentation view for different graph setting lets you change views quickly
perspectives and analysis tools. and easily.

Sweep/Curve Settings — Every sweep Dynamic Zoom — Zoom in and Operation Buttons — All essential
can be individually turned on or off, move your focus to any part of functions at your fingertips; select with
change color, thickness and position. the curve. mouse, function keys or touch screen.

Built-in-decision support is provided by using a built-in


analysis tool based on the international standard DL/T 911-2004.

Automated analysis compares two curves using an


algorithm that compare amplitude as well as
frequency shift and lets you know if the difference
is severe, obvious, or light.
FRAX 101
Sweep Frequency Response Analyzer

Considerations When Performing SFRA The Power of Wireless


Measurements FRAX 101 uses class 1 Bluetooth® wireless communication.
SFRA measurements are compared over time or between Class 1 Bluetooth® has up to 100 m range and is designed
different test objects. This accentuates the need to perform for industrial applications. An optional internal battery
the test with the highest repeatability and eliminates the pack is available for full wireless flexibility. Shorter and
influence from external parameters such as cables, more light-weight cables can be used when the user is
connections and instrument performance. FRAX offers all liberated from cable communication and power supply
the necessary tools to ensure that the measured curve cables.
represents the internal condition of the transformer.
A standard USB interface (galvanically isolated) is included
Good Connections for users who prefer a direct connection to their PC.
Bad connections can
compromise the test results IMPORT AND EXPORT
which is why FRAX offers a The FRAX software can import data files from other FRA
rugged test clamp that instruments making it possible to compare data obtained
ensures good connection to using another FRA unit. FRAX can import and export data
the bushings and solid according to the international XFRA standard format as
connections to the well as standard CSV and TXT formats.
instrument.
Optimized Sweep Setting
Contacts made with the C-clamp The software offers the user an unmatched feature that
guarantee good connections allows for fast and efficient testing. Traditional SFRA
Shortest Braid
Concept systems use a logarithmic spacing of measurement points.
The connection from the cable shield to ground has to be This results in as many test points between 20Hz and
the same for every measurement on a given transformer. 200Hz as between 200KHz and 2MHz and a relatively long
Traditional ground connections techniques have issues measurement time.
when it comes to providing repeatable conditions. This The frequency response from the transformer contains a
causes unwanted variations in the measured response for few resonances in the low frequency range but a lot of
the highest frequencies that makes analysis difficult. resonances at higher frequencies. FRAX allows the user to
The FRAX braid drops down from the connection clamp specify less measurement points at lower frequencies and
next to the insulating discs to the ground connection at high measurement point density at higher frequencies.
the base of the bushing. This creates near identical The result is a much faster sweep with greater detail
conditions every time you connect to a bushing whether where it is needed.
it is tall or short. Variable Voltage
The applied test voltage may affect the response at lower
frequencies. Some FRA instruments do not use the 10 V
peak-to-peak used by major manufacturers and this may
complicate comparisons between tests. FRAX standard
voltage is 10 V peak-to-peak but FRAX also allows the
user to adjust the applied voltage to match the voltage
used in a different test.

FTB 101
Several international FRA guides recommends to verify the
integrity of cables and instrument before and after a test
using a test circuit with a known FRA response supplied
by the equipment manufacturer. FRAX comes with a field
test box FTB101 as a standard accessory and allows the
user to perform this important validation in the
field at any time
The laptop can be operated by touch screen and the communication is and secure
wireless via Bluetooth. Measurement ground braids connect close to the
connection clamps and run next to the bushing to the flange connection
measurement
to avoid cable loops that otherwise affect the measurement. quality.

FTB 101 Field Test Box


FRAX 101
Sweep Frequency Response Analyzer

DYNAMIC RANGE SPECIFICATIONS


Making accurate measurements in a wide frequency range General
with high dynamics puts great demands on test equipment, FRA Method: Sweep frequency (SFRA)
test leads, and test set up. FRAX 101 is designed with these Frequency Range: 0.1 Hz - 25 MHz, user selectable
requirements in mind. It is rugged, able to filter induced Number of Points: Default 1046,
User selectable up to 32,000
interference and has the highest dynamic range and
Measurement time: Default 64 s, fast setting,
accuracy in the industry. FRAX 101 dynamic range or noise 37 s (20 Hz - 2 MHz)
floor is shown in red below with a normal transformer Points Spacing: Log., linear or both
measurement in black. A wide dynamic range, low noise Dynamic Range/Noise Floor: >130dB
floor, allows for accurate measurements in every Accuracy: ±0.3 dB down to -105 dB
transformer. A margin of about 20 dB from the lowest (10 Hz - 10 MHz)
response to the instruments noise floor must be IF Bandwidth/Integration Time: User selectable (10% default)
maintained to obtain ±1 dB accuracy. Software: FRAX for Windows 2000/ XP/Vista
PC Communication: Bluetooth and USB
(galvanically isolated)
Calibration Interval: Max 3 years
Standards/guides: Fulfill requirements in Cigré
Brochure 342, 2008
Mechanical condition assessment
of transformer windings using
FRA and Chinese standard DL/T
911-2004, FRA on winding
deformation of power
transformers, as well as other
international standards and
recommendations
Analog Output
Channels: 1
Compliance Voltage: 0.2 - 20 V peak-to-peak
Measurement Voltage at 50 Ω: 0.1 - 10 V peak-to-peak
Output Impedance: 50 Ω
Protection: Short-circuit protected
An example of FRAX 101’s dynamic limit (red) and transformer
measurement (black) Analog Input
Channels: 2
Sampling: Simultaneously
Input Impedance: 50 Ω
FEATURES AND BENEFITS Sampling Rate: 100 MS/s
■ Smallest and most rugged FRA instrument in the
Physical
industry.
Instrument Weight: 1.4 kg/3.1 lbs
■ Guaranteed repeatability by using superior cabling Case and Accessories Weight: 15 kg/33 lbs
technology, thus avoiding the introduction of error due Dimensions: 250 x 169 x 52 mm
to cable connection and positioning (which is common 9.84 x 6.65 x 2.05 in
Dimensions with Case: 520 x 460 x 220 mm
in other FRA manufacturers’ equipment).
20.5 x 18.1 x 8.7 in.
■ Fulfills all international standards for Sweep Frequency Input Voltage: 11 - 16 V dc or 90 - 135 V ac and
Response Analysis (SFRA) measurements. 170 - 264V ac, 47-63 Hz

■ Highest dynamic range and accuracy in the industry Environmental


allowing even the most subtle electro-mechanical Operating Ambient Temp: -20°C to +50°C / -4°F to +122°F
Operating Relative Humidity: < 90% non-condensing
changes within the transformer to be detected.
Storage Ambient Temp: -20°C to 70°C / -4°F to +158°F
■ Wireless communication allows easy operation without Storage Relative Humidity: < 90% non-condensing
the inconvenience of cable hook up to a PC. CE Standards: IEC61010 (LVD) EN61326 (EMC)

■ Battery input capability allows for easy operation PC Requirements


(PC not included)
without the need for mains voltage supply.
Operating System: Windows 2000/ XP / Vista
■ Advanced analysis and support software tools allows for Processor: Pentium 500 MHz
sound decision making with regard to further diagnostics Memory: 256 Mb RAM or more
analysis and/or transformer disposition. Hard Drive: Minimum 30 Mb free
Interface: Wireless or USB (client)
FRAX 101
Sweep Frequency Response Analyzer

OPTIONAL ACCESSORIES
■ The built-in battery pack offers flexibility when
performing tests on or off the transformer.
■ The Active Impedance Probe AIP 101 should be used
when measuring grounded connections such as to the
transformer tank or a bushing connected to the
transformer tank. AIP 101 ensures safe, accurate and
easy measurements to ground.
■ The Active Voltage Probe AVP 101 is designed for
measurements when higher input impedance is needed.
AVP 101 can be used for measurements where up to
1 MΩ input impedance is required.
FRAX cable set consists of double shielded high quality cables, braid
for easy and reliable ground connection, and clamp for solid
connections to the test object.

ORDERING INFORMATION
Item (Qty) Cat. No. Item (Qty) Cat. No.
FRAX 101 complete with: Optional Accessories
ac/dc adapter, mains cable, Battery option, 4.8 Ah AC-90010
ground cable 5 m (16 ft), transport case,
USB cable, Bluetooth adapter, Windows software, Calibration set AC-90020
4 x 3 m (10 ft) ground braid set, 2 x C-clamp, Active impedance probe AIP 101 AC-90030
field test box, generator cable 18 m (59 ft), Active voltage probe AVP 101 AC-90040
measure cable 18 m (59 ft), manual AC-19090
FRAX Demo box FDB 101 AC-90050
FRAX 101, incl. battery, complete with:
Field Demo Box FTB 101 AC-90060
ac/dc adapter, mains cable,
ground cable 5 m (16 ft), transport case, Ground braid set, 4 x 3 m including clamps GC-30031
USB cable, Bluetooth adapter, Windows software, FRAX Generator cable, 2xBNC, 9 m (30 ft) GC-30040
4 x 3 m (10 ft) ground braid set, 2 x C-clamp, FRAX Generator cable, 2xBNC, 18 m (59 ft) GC-30042
field test box, generator cable 18 m (59 ft),
measure cable 18 m (59 ft), FRAX Measure cable, 1xBNC, 9 m (30 ft) GC-30050
battery pack, manual AC-19091 FRAX Measure cable, 2xBNC, 18 m (59 ft) GC-30052
FRAX C-clamp GC-80010
FRAX for Windows SA-AC101

Registered to ISO 9001:2000 Cert. no. 10006.01


FRAX101_DS_en_V01
Item 7B
IDAX 300
Insulation Diagnostic Analyzer

IDAX 300
Insulation Diagnostic Analyzer

■ Fast and accurate moisture assessment in


power transformers
■ Well proven technology; IDA/IDAX units
have been in field use for more than 10
years
■ Reliable results at any temperature
■ Automated analysis of moisture content
and oil conductivity — decisions at your
finger tip
■ True frequency domain measurement for
highest noise immunity
■ Performs non-intrusive insulation testing
of transformers, bushings, cables and
generators

DESCRIPTION IDAX is a revolutionary insulation diagnostic instrument


IDAX 300 provides an accurate and reliable condition based on DFR (Dielectric Frequency Response), also
assessment of insulation in transformers, bushings, known as FDS (Frequency Domain Spectroscopy). This
generators and cables. The IDAX 300 system maximizes analysis technique has been used in laboratories for
the outcome of maintenance activities allowing for load decades and IDA/IDAX was the first instrument designed
and service life optimization. for field use (1997). The IDA/IDAX instrument and
measurement principle has been used and verified around
IDAX 300 is smaller, lighter and faster than its predecessor
the world over the last ten years.
IDAX 206. It maintains the same accuracy and ability to
provide reliable data using true DFR (Dielectric Frequency One of the most important applications for IDAX is to
Response), also known as FDS (Frequency Domain determine the moisture content in transformer insulation.
Spectroscopy), without compromises. The state-of-the-art Moisture in the insulation significantly accelerates the
software makes testing both easier and faster, allowing aging process. Moisture can cause bubbles between
transformer moisture assessment in less than 18 minutes. windings, resulting in catastrophic failures. IDAX provides
reliable moisture assessments in one test. The test can be
IDAX 300 measures the capacitance and tan delta/power
made at any temperature and takes less than 18 minutes.
factor of the insulation between power transformer
windings at multiple frequencies. Plotting the results as a Decisions on maintenance and/or replacement should be
curve makes it possible to assess the condition of the oil based on knowing the condition of the insulation and the
and solid insulation, assess the moisture level in the solid expected loading of the unit. Adding just a few operational
insulation and other potential insulation problems. The test years to the expected end-of-life for a transformer,
can be performed at any temperature. generator or cable by optimizing the working condition
based on reliable diagnostic data means substantial cost
savings for the equipment owner.
APPLICATION
With an aging power transformer population, today’s The FDS technology can also be used to assess the
electrical utility industry faces a tough challenge as condition and aging of the insulation in bushings, CTs and
transformer failures and consequent repair and revenue circuit breakers. Numerous ongoing research projects at
loss costs millions of dollars. Transformers have become institutes and universities around the world is adding
one of the most mission critical components in the experience and value to users of IDAX.
electrical grid. The need for reliable monitoring and
diagnostic methods drives the world’s leading experts to
evaluate new technologies that improve reliability and
optimize the use of every grid component [1].
IDAX 300
Insulation Diagnostic Analyzer

Water in Oil vs. Paper


Assessing reliable moisture content in transformer
insulation based on oil sample tests is unreliable as the
water migrates between the solid insulation and oil as
temperature changes. An oil sample has to be taken at
relatively high temperature and when the transformer is in
equilibrium. Unfortunately, this is a rare state for
transformers thus resulting in unreliable assessments.
Figure 1 shows how the significant and potentially critical
difference of 0.5% respectively 3.0% moisture in paper,
correlates to the insignificant difference of 1 respectively 4
Parts Per Million (PPM) in an oil sample obtained at 20oC
(68oF) [2].
Figure 1: Water in oil vs. paper correlation is unreliable at low temperature
The Test
Dielectric loss or power factor is frequency and
temperature dependent, so by injecting test signals at
discrete frequency steps typically between 1 kHz and 1-2
mHz while recording results at each point, a curve is
created (Fig 2).
This profile represent the properties of the insulation
material in the transformer and will be used in further
analysis as described below. The oil temperature is
recorded to be used in the model analysis described
below.

The Model
The insulation between the windings in a transformer
consists of a solid and a liquid part. The solid part consists
of barriers and spacers to create an oil duct for cooling Figure 2: Power factor curve presented as capacitance and loss

purposes (Fig 3). The model formula varies all insulation


parameters to simulate every possible geometrical design.
The model also applies Arrhenius equation to compensate
for temperature dependence in the material [3].
The IDAX software creates new model curves and
compares them to the measured curve until the best
possible match is reached. The final results are presented
as a percent of moisture in paper and a separate value for
oil conductivity (Fig 4 and 5).

What Controls the Curve?


The general rule is that moisture is visible in the highest
and in lowest frequencies. Oil conductivity is dominant in
the medium frequency and the temperature shifts the curve
to the right and to the left respectively (Fig 6). Figure 3: Typical insulation design

Figure 4: Before matching — green-model, red-measurement Figure 5: After matching — result: 0.4% at 20oC
IDAX 300
Insulation Diagnostic Analyzer

One Point Is Not Enough


Traditional tan delta/power factor testing provides one
value at mains frequency 50/60 Hz. This is where the
IDAX method makes the difference. Figure 7 show that a
single power factor value cannot provide conclusive
information about the potential problem. At best it can
provide information that a problem exists. In this example,
two transformers have the same power factor value at 60
Hz. However, one of them is wet (3.6%) and should be
considered for a dry-out while the oil in the other unit
should be replaced or refurbished. The IDAX method
provides accurate and conclusive information in one test.

Test Procedure
The test preparation and procedure is similar to a standard Figure 6: Oil conductivity and moisture influence
tan delta/power factor test, which means that the
transformer has to be off-line and preferably disconnected.
The IDAX software operates on Windows XP and Vista
and utilizes standard USB communication. The software
guides the user through a test template where all
connections are illustrated in Figure 8. Color markings on
clamps makes it easy to connect according to the built in
instructions. The test can be started as soon as the test
cables are connected. Error messages on the screen inform
the user if there are any problems with connections or
cables.
IDAX 300, in the standard version, is equipped with an
input circuitry capable of measuring multiple test modes
without having to change cable connections on the
transformer. As an option, the IDAX 300 can be equipped
Figure 7: Blue — dry with bad oil. Red — wet with good oil
with an additional current measurement channel that
allows for two completely independent measurements at
the same time, thus minimizing test time.
The calibration set enables simple and reliable calibration
of the IDAX system. It also reduces instrument downtime
and transport cost as the calibration box is the only part
that needs to be sent in for calibration. The new design
allows calibration in any local certified calibration facility
to avoid long shipment turn-around times and transport
costs.

Conclusion
IDAX is a well-proven system for determining moisture
content in transformer insulation. The instrument and
method including the modeling software has been tested
and verified with numerous customers.
Figure 8: Example of connections to a three-winding transformer
References
[1] S.M. Gubanski, J. Blennow, L. Karlsson, K. Feser, S.
Tenbohlen, C. Neumann, H. Moscicka-Grzesiak, A.
Filipowski, L. Tatarski “Reliable Diagnostics of HV
Transformer Insulation for Safety Assurance of Power
Transmission System” Cigre Paris Aug 2006
[2] From. P. J. Griffin, C. M. Bruce and J. D. Christie:
“Comparison of Water Equilibrium in Silicone and
Mineral Oil Transformers”, Minutes of the Fifty-Fifty
Annual Conference of Doble Clients, Sec. 10-9.1, 1988
[3] U. Gäfvert, L. Adeen, M. Tapper, P. Ghasemi, B.
Jönsson, “Dielectric Spectroscopy in Time and
Frequency Domain Applied to Diagnostics of Power
Transformers”, Proc. Of the 6th ICPADM, Xi’an, China,
2000
IDAX 300
Insulation Diagnostic Analyzer

General
Mains Input (nominal): 90 - 265 V ac, 50/60 Hz
SPECIFICATIONS Power Consumption (max): 250 VA
Communication Ports: USB 2.0 and LAN
Output
Voltage/current ranges, 10 V: 0 - 10 Vpeak 0 - 50 mA peak Physical
Voltage/current ranges, 200 V: 0 - 200 Vpeak 0 - 50 mA peak Instrument Weight: 4.9 kg/11 lbs
Frequency Range: 0.1 mHz - 10 kHz Case and Instrument Weight: 9.9 kg/22 lbs
Accessories Weight: 8.5 kg/18 lbs (soft bag)
Measurements
Dimensions: 335 x 300 x 99 mm
Inputs: Channel 1, channel 2, ground
17.7 x 6.3 x 16.1 in
Capacitance Range: 10 pF - 100 µF
Dimensions with Case: 520 x 430 x 220 mm
Accuracy: 0.5% + 1 pF
20.5 x 17 x 8.7 in.
Dissipation Factor Range: 0 - 10 (with retained accuracy of
capacitance; otherwise higher) Environmental
Accuracy: >1% +0.0003, 1 mHz - 100 Hz, Operating Temperature: 0°C to +50°C /-32°F to +122°F
C > 1 nf Storage Temperature: -40°C to 70°C / -40°F to +158°F
>2% +0.0005, 100 Hz - 1 kHz, Humidity: <95% RH, non-condensing
C > 1 nF
CE Standards: IEC61010 (LVD) EN61326 (EMC)
Noise Level: Max 500 µA at 50 Hz/60 Hz
Test Modes, 2 Channels: UST-1, UST-2, UST-1+2, GST, PC Requirements
GST-Guard-1, GST-Guard-2, Operating System: Windows 2000/ XP / Vista
GST-Guard-1+2. CPU/RAM: Pentium 500 MHz/512 Mb or better
With 2-ch measurement option Interface: USB 2.0
additionally UST-1+UST-2, UST-
1+GST-Guard-2, UST-2+GST-Guard-
1, UST-1+2+GST
Calibration: Calibration set allows field
calibration, recommended interval
2 years

ORDERING INFORMATION
Item (Qty) Cat. No. Item (Qty) Cat. No.
IDAX 300 complete with: Optional Accessories
mains cable, ground cable 5 m (16 ft),
Calibration set for IDAX 300 AG-90010
USB cable, transport case, Windows software,
manual, generator cable 18 m (59 ft), IDAX demo box IDB 300 AG-90020
measure cable 18 m (59 ft) red, 2nd channel option for IDAX 300 AG-90200
measure cable 18 m (59 ft) blue, Ground cable, 5 m (16 ft) GC-30060
soft case for cable AG-19090
Generator cable, 9 m (30 ft) GC-30310
IDAX 300, 2 channels, complete with:
mains cable, ground cable 5 m (16 ft), Measuring cable, 2 x 9 m (30 ft), red GC-30320
USB cable,transport case, Windows software, Measuring cable, 2 x 9 m (30 ft), blue GC-30330
manual, generator cable 18 m (59 ft), Generator cable, 18 m (59 ft) GC-30312
measure cable 18 m red (59 ft),
Measuring cable, 2 x 18 m (59 ft), red GC-30322
measure cable 18 m (59 ft) blue,
soft case for cable AG-19092 Measuring cable, 2 x 18 m (59 ft), blue GC-30332
IDAX for Windows SA-AG101

Registered to ISO 9001:2000 Cert. no. 10006.01


IDAX300_DS_en_V01
8.PD Measurement for
MV and HV.
(Applicable to latest
measurement on
Switchgear &
Transformer)
Item 8A
Item 8B
Partial Discharge
Online Testing Technology
Scope of supply:

Item 1 3 Phase PD Spot Tester - Type: OSM-Longshot© WR Xi


(new Waverunner Xi model)

Hardware Description:
Digital PD Detector comprising of a fully calibrated wideband, 4-channel digitizing
oscilloscope module, frequency range DC to 400MHz.
Supplied with internal 2 GHz pentium PC.
This allows for 3-phase testing/monitoring of HV Plant including:
motors / generators, cables / switchgear, transformers and other HV Plant.
The input impedance to the unit is 50 Ohms allowing for connection of High Frequency
Current Transformers (HFCT’s) Ferrite & Rogowski), Capacitive Couplers (TEV sensors),
Acoustic/Ultrasonic Sensors for on-line PD testing and blocking capacitors etc for off-line
testing.
Supplied with Full Instruction Manual, Mini Keyboard, Optical Mouse and 1x 40GB USB Hard
Drive and a set of 4x 20m BNC test cables and 4x 50Hz Filters.
The equipment is designed to operate on ac mains supply systems from 110V to 240V, 50-
60Hz. The unit is supplied with a soft carry case for ease of transportation.
The OSM-Longshot© Waverunner Xi Unit is supplied with a 36 month Warranty (in normal use)

Software Description:
The Unit is supplied pre-programmed with 4x Integrated PD Software Packages, all of
which run under the WindowsTM operating system, as follows:

PD Gold© Data Capture and Measurement Software


For collecting synchronous, 50/60Hz Power Cycle PD data, with automatic collection of
individual PD Pulses.
The software contains a dedicated ‘Machines’ Module dedicated to the measurement of PD
Data in Rotating HV Motors and Generators.

PD Reader© Data Analysis and Reportage Software


This ‘reads’ the PDGold© files collected and automatically analyses the data collected using
the ‘Event Recogniser’ Software Module.
The software allows for standard PD Test Reports to be automatically generated.
A PC software version is also provided to allow post-analysis of the PD Data on any PC
ScopeControl© PD Pulse Capture Software
This allows the user to collect individual PD pulses from up to 4 channels simultaneously
enabling the user to carry out time-of-flight measurements of PD pulse arrival on a number of
PD sensors at once.

ScopeControlReader© PD Pulse Analysis and Reportage Software


This reads the individual PD pulses collected by the ScopeControl© software from up to 4
channels simultaneously enabling the user to carry out post-test analysis of the PD data
collected in the field.
A PC version of this software is also provided to allow post-analysis of the PD Data on any
PC owned by the customer.

Free upgrades on the above software packages are provided for 12-months from the date of
purchase. Software support packages are available beyond this 12-month period on request.

PDGold©
The PDGold© program (Main Page shown below) contains all the functions that allow control
of the OSM-Longshot instrument, to set the correct values of the acquisition parameters, to
acquire and visualise the PD dataset in order to get an immediate diagnostic response.

PDGOLD© PD ACQUISITION SOFTWARE - MAIN PAGE

The PDGold© software collects the PD data in 200x ‘slots’ across the 50Hz (or 60Hz) power
cycle, one cycle at a time, followed by a processing stage of a few seconds, followed by the
acquisition and processing of a second cycle and so on.
Each signal acquired is synchronised by the AC mains voltage waveform supply (or other
volatge signal). The software thus allows the user to observe this 360o plot of the PD
behaviour showing both the individual 20ms ‘shots’ and the cumulative measurements of all
those taken up to that point, in ‘real-time’.
For the standard PDGold© measurement this would be left to run typically for 3 to 5 minutes
with around 100 to 200 individual power cycles usually saved.

Page 2 of 6 June 2007


Item 2 PD Sensors and Accessories

1x External, Low Voltage PD Calibrator Type HVS 998/0011


Battery operated PD Calibrator for injecting a known PD signal across the test circuit.
Provides four selectable outputs, 10pC, 100pC,1000pC and 10,000pC

3 x Rogowski Coil Type HVS 994C.T. Split


Split-Core RF Current Transducer Type HVS 994C.T. with 95mm internal diameter for
connection around the core of HV supply cables to the test circuits.
Suitable for HV Motor/Generator Testing with high supply currents as the Rogowski Coil
Sensors do not Saturate with high currents passing through them.
One transducer is required per circuit to be monitored.

3 x Ferrite HFCT Type: CAE 140/100 Split


High Sensitivity, Split-Core RF Current Transducer Type CAE 140/100
Split with 100mm internal diameter for connection around the earth screen of HV supply
cables to the test circuits.
Suitable for HV cable and switchgear testing where higher sensitivity to PD activity is
required (when compared with Motor Testing).
One transducer is required per circuit to be monitored.

1x Acoustic Probe kit Type HVSL - AA-b40


Acoustic kit comprising of a Magnetic Airborne Acoustic probe, Air Acoustic probe and
Conditioning Amplifier with power unit.

3 x Capacitive Probe Coupler Type HVSL TEV


Magnetic Capacitive Probe for the measurement of PD signals emanating from inside
Metalclad HV plant, particularly metalclad switchgear etc.
One transducer is required per switchgear panel to be monitored.

4x 50HZ Filter-Decoupler Units

8 x 10m BNC Data Cables + 6 x Through Connectors


(to make 4x 10m, 4x 20m or 2 x 40m BNC data cables for PD testing )

1x IP67 Rated Equipment Case for above items


The above sensors are supplied in a waterproof equipment case fitted with foam inserts and
compartments.

Customer Training Packages


- for users of OSM-Longshot© PD Spot Testers
Due to the technical nature of the OSM PD test technology, IPEC/HVSL strongly
recommend that the customer purchases a dedicated training course in order that they get
the maximum performance out of the OSM technology.

Page 3 of 6 June 2007


1.0 OSM-Longshot© PD Spot Testers
OSM PD Spot Testers listed contain the Standard PDGold© Software which has used been
used in the IPEC PD Spot Testers for the past 5 years.

• The PD Gold© Software’s functionality includes:


Capture of signals synchronously across the 50Hz (or 60Hz) power cycle
Provides a PD (partial discharge) threshold level for recording the number of pulses (count)
per cycle

• Noise waveforms using a second channel can be used for ‘gating’ external pulsed
interference
The software divides the power period into slots, and the peak signal is then detected for
each slot, allowing the user to observe familiar phase-related patterns of discharge.
PD levels are given in mV and dB as standard and also in pC for cable testing when used
with calibrated HFCT’s.

• A new event recogniser system is incorporated into the analysis software


Keeps segments of the PD waveforms
Classifies these PD pulses into three types: Cable PD, Switchgear PD and Noise.
This can often eliminate the need for background noise reduction.
A machine page is available for testing high voltage rotating machines (motors/generators)

• Full print preview page for outputting results to printers or adobe pdf files
The spot tester is designed for a wide variety of use including on-line PD Testing of the
insulation in HV Cables, Switchgear, Transformers, Motors/Generators and other HV Plant.
It is very able to measure on-line PD activity, and the system is offered with a variety of
sensors for this type of work.
The system is also capable of accurate laboratory measurements, where synchronous
voltage measurements and PD calibrations are needed. The time for which measurements
can be recorded is only limited by the internal RAM of the PC.
It is not unusual to run the system for several hours up to a week, with continuous data
monitoring.

The 1.0 OSM-Longshot© PD Spot Testers unit is not sold primarily as a monitoring device
(it’s primary use being PD ‘Spot Testing’.
These spot testers are not specifically designed to be permanently installed and driven
remotely, and whilst this is entirely feasible, other options are available for the permanent
monitoring application.
The PDGold© Longshot system can be considered as the most versatile (and best) PD spot
testing device on the market.
It is generally regarded that PD monitoring should be carried out by permanently installed PD
Monitors with web/remote access (for information on long-term PD Monitoring Technologies
contact your supplier).

The applications for on-line testing tend to be plant specific. Hence there are cable related
parts to the event recogniser analysis. Here the results can be expressed in pC so that
discharges on all cable types, and at all detectable distances down the cable, can be
compared in magnitude.
There are also switchgear related parts to this, where the results can be expressed in dB to
relate back to the traditional way switchgear PD results were displayed.

Page 4 of 6 June 2007


9. Transformer Oil
Dielectric Test Set
Item 9A
OTS60PB, 60AF/2, 80AF/2, 100AF/2, VCM100
Automatic Oil Test Sets

OTS60PB, 60AF/2, 80AF/2, 100AF/2, VCM100


Automatic Oil Test Sets

■ Microprocessor controlled fully automatic


oil test sets
■ Wide choice of vessels and accessories
■ Portable and laboratory units

DESCRIPTION in an attached compartment. Stirring is carried out by a


motor driven paddle stirrer.
The Megger range of automatic oil testers offer fully
automatic testing with many advanced features. The design The OTSAF/2 range are laboratory instruments with many
allows the operator to simply prepare an oil test vessel, advanced features. Three versions are available with
load it with the sample oil, place it in the chamber and maximum test voltages of 60 kV, 80 kV and 100 kV. They
initiate the test sequence. The test set then carries out, the offer fully automatic operation plus the benefit of a built
series of tests as specified in a large number of oil testing in printer to produce a hard copy of the test results and
specifications. These define the sequence of tests including the ability to program up to five user defined tests for
the stand and stir times, rate of voltage rise and number of individual applications. The withstand test can be set to
tests resulting in a calculation of the average value of the operate at any test voltage and with an initial stand time.
oil breakdown strength. Withstand or proof testing can The dot matrix liquid crystal display can also be set to
also be selected. This test subjects the oil to a preselected read in one of six languages. An oil test vessel, configured
voltage for 1 minute to check for a breakdown. to suit the IEC156 test specification, is supplied with the
instrument.
The OTS60PB is a fully automatic, battery powered,
portable oil test set. The test voltage is electronically A large, backlit, liquid crystal display shows test menus,
controlled to the maximum of 60 kV. Designed for on site set up screens and results. The resolution of the high
testing, the instrument is supplied in a rugged carrying voltage output is displayed to 0,1 kV.
case with a handle for ease of transportation. An internal Results can be printed on the internal dot matrix printer or
rechargeable battery gives a large number of tests before transferred via the RS232 interface to an external printer or
recharging. A clear display shows a menu of test options PC. Printouts are automatically time and date stamped.
and guides the operator through the set up programme,
illustrates the correct test electrodes and gap to use, shows Standard stirring with the OTSAF/2 is achieved by a
the progress of each test and gives the results of the test magnetic stirrer bar. Additional vessels are available
sequence. The result can be set to give either a numerical optionally, including one suitable for testing to the ASTM
average (with standard deviation where specified) or a D1816 specification. This calls for stirring to be carried out
pass/fail message. The display can be set to read in by a motor driven impeller. Each test can be selected with
English, French, German, Italian, Spanish and Portuguese. either magnetic stirring, propeller stirring or no stirring.
An optional printer kit enables hard copies of results to be
The VCM100 is a calibration meter suitable for verifying
produced. Accessories, such as the battery charger, spare
the calibration of oil test sets. The meter will enable the
vessels, spare electrodes and a spacing gauge are located
OTS60PB, 60AF/2, 80AF/2, 100AF/2, VCM100
Automatic Oil Test Sets

high voltage output to be checked, traceable to national with the VCM100. Later versions of the OTSAF also have
standards, and is suitable for all recent laboratory models the ‘CHECK CALIBRATION’ procedure.
of Megger oil dielectric strength test sets such as the
OTSAF series and the OTS auto and semi automatic series.
The calibration meter fits in the oil test set chamber in
place of a standard vessel. The design ensures that the
load to the transformer is similar to the load during an oil
dielectric strength test. The voltage indication is viewed on
an analogue display marked from 0 to 100 kV with 2 kV
SPECIFICATION
divisions. The scale also shows pass tolerance bands to Panel meter scaling 0 - 100 kV in 2 kV divisions
enable a quick assessment of the accuracy to be made. Accuracy ±3% of full scale
The meter is supplied in a protective bag.
Temperature Range
Oil test sets will display the individual breakdown voltage Operational 0°C to 40°C (32 to 104°F)
and their average value. The VCM100 allows the actual Storage -30°C to +70°C (-22 to 158°F)
applied voltage to be quickly and easily checked against
the displayed value giving immediate confidence in the Humidity Range
calibration of the oil test set. Operational 80% RH at 40°C (104°F)
Storage 93% RH at 40°C (104°F)
OTS/VCM100
■ Allows a quick check of high voltage output to be made`
■ Tests up to 100 kV with accuracy of 3% Safety The meter is only approved for use with Megger oil test
■ Easy to read mirror arc display with tolerance bands sets.
Dimensions 198 mm x 235 mm x 102 mm
OPERATION (7,8 x 9,25 x 4 inches)
The OTSAF/2 series are programmed with a test sequence Weight 2,4 kg (5,3 lbs)
suitable for using the VCM100 called ‘CHECK
CALIBRATION’. This sequence causes the output of the oil
test set to ramp up from 0 kV to the maximum voltage
value, pausing at each 10 kV point for 10 seconds to allow
the calibration to be checked.
Other versions of Megger oil test sets (such as the OTSAF,
OTS VCM100 Scale Plate
OTS60 auto and OTS75 auto) can be used in manual
mode or with a low rate of voltage rise to allow checking

Parameters of test specifications (programmed in OTS60PB, OTS60AF/2, OTS80AF/2 and OTS100AF/2)

Test Spec. Electrode Initial Rate of rise Intermediate Intermediate Number Maximum Duration of Selected
Selected Shape Stand of Test Stir Time Stand Time Of Tests test sequence
Voltage OTS60B OTS80AF/2 OTS100AF/2
OTS60AF/2
5min test B 1 min. 2kV/s 30 s 30 s 3 4min. 30s 5min. 5min. 30s
IEC156 etc A,B 5 min. 2kV/s 2 min. 2 min. 6 18min. 19min. 20min.
(option 1) (option 2)
ASTM D877 C 2 min. 20 s 3 kV/s - 1 min. 5 8min. 8min. 33s 9min. 7s
ASTM D1816 A 3 min. 0,5 kV/s Continuous 1 min. 5 17min. 20 min. 20s 23 min. 40s
UNE21 A,B 10min. 2 kV/s 1 min. 4 min. 6 38 min. 39 min. 40 min.
Withstand A B 0-99 min 55s ** 2 kV/s Ramps to preselected value of 1 minute or breakdown
Withstand B B 0-99 min 55s ** 2 kV/s As above and continues to breakdown or maximum value of test set
Custom (1-5)* - 0-99 min 55s * 0,5-5,0 kV/s* 0-99 min 55s* 0-99 min 55s* 1-99 - - -
BS5730a A,B - 2 kV/s 1 min. 1 min. Withstand test at 22 kV, 30 kV or
40 kV (depending on equipment
category and electrode gap) for 60 s.
If breakdown occurs another two
tests are carried out, both must pass
if sample is OK.
IEC156 etc. includes BS148, BS5874, VDE 0370, NFC 27, CE1344, OCT 6581, SABS555, AS1767, STA8286 and IP295.
NFC27, STAS286 and UNE21 omit the first breakdown value from the average calculation.
STAS286 has a 2 minute intermediate stand time.
The OTS60PB is also programmed with BS5730-LEPLC which is similar to BS5730a but ramps to breakdown after a successful test.
* User Schedule
** OTSAF/2 only.
OTS60PB, 60AF/2, 80AF/2, 100AF/2, VCM100
Automatic Oil Test Sets

OTS60PB OTS60AF/2, OTS80AF/2 AND OTS100AF/2

Features ■ Powered by internal, rechargeable battery ■ Automatic laboratory set (see table opposite)
■ Fully automatic operation (see table opposite) ■ Built in printer and RS232 output
■ Pass/fail limit setting ■ Custom test facility

Test voltage 60 kV maximum (30 kV - 0 - 30 kV) OTS60AF/2:60 kV maximum (30 kV - 0 - 30 kV) @ 61,8 Hz
OTS80AF/2:80 kV maximum (40 kV - 0 - 40 kV)
OTS100AF/2:100 kV maximum (50 kV - 0 - 50 kV)

Power Internal, rechargeable 12 V, 12 Ah battery 110 V, 120 V, 220 V, 240 V ±10%


supply (giving typically 12 hours continuous use) 50/60 Hz
Charger supply 85 to 265 V, 50/60 Hz Four pre-selectable values
Optional 12 V supply lead enables operation
from vehicle cigarette lighter socket

Display Dot matrix LCD giving alphanumeric information and kV test voltage

Resolution 1 kV 0,1 kV

Dimensions 373 H x 259 W x 247 D mm(without accessories) 464 H x 502 W x 319 D mm


14,6 H x 10,2 W x 9,8 D in. approx. 18,3 H x 19,7 W x 12,5 D in. approx.

Weight 19 kg (42 lb) without accessories 41 kg (90 lb) approx.


Fuses 2 x F6,3 A, IEC127/1, 20 mm x 5 mm, HBC 2 x F6,3 A, IEC127/1, 20 mm x 5 mm, HBC
T2 A, IEC127/5, 20 mm x 5 mm, HBC for 220/240 V
T4 A, IEC127/5, 20 mm x 5 mm, HBC for 110/120 V

Temperature Operation: 0°C to 40°C Operation: 0°C to 40°C

Range Storage: -30°C to +65°C Storage: -40°C to +70°C

Humidity Operation: 80% RH at 40°C Operation: 80% RH at 40°C

Range Storage: 93% RH at 40°C, 95% RH at 25°C cyclic Storage: 93% RH at 40°C, 95% RH at 25°C

Safety Designed to incorporate where appropriate Meets the requirements of IEC1010-1 (1991)
IEC1010-1, safety class I. Safety interlock to BS5304 (1988) ‘Guarding of
Safety interlock to BS5304 (1988) ‘Guarding of Machinery’ standard.
Machinery’ standard.

Other RS232 output plus optional printer kit RS232C 5 pin DIN socket
Includes battery charger and four test vessels Five custom tests allowing; 1 to 99 tests
Option to set pass/fail breakdown values 0,5 to 5 kV/s rate of voltage rise
0 to 99 min. 59 s stir and stand times
Averaging start from first to last test
OTS60PB, 60AF/2, 80AF/2, 100AF/2, VCM100
Automatic Oil Test Sets
PRINTER INFORMATION
The OTS60PB Printer Kit includes
a 24 column impact printer with
integral rechargeable batteries and
Electrode Shape A Electrode Shape C a mains adaptor which operates
36mm Mushroom Electrodes 25,4 mm (1 in) Cylindrical Electrodes from 85 V to 265 V a.c. (50/60 Hz).
The printer is 105 mm x 195 mm
x 90 mm and weighs 625 g.

Electrode Shape B Electrode Shape D


12,7 mm (0,5 in) Spherical Electrodes 25,4 mm (1 in) Cylindrical Electrodes
with 0,5mm edge radius

ORDERING INFORMATION
Item (Qty) Order Code Item (Qty) Order Code
Laboratory Oil Test Set Portable oil test set (60 kV) OTS60PB
60 kV OTS60AF/2
80 kV OTS80AF/2 Included Accessories
100 kV OTS100AF/2 Padded protective carrying case with handle
and shoulder strap 6420-102
Included Accessories 4 x 600 ml capacity oil test vessels without lid
Mains power supply lead 25424-860 Pair of spherical electrodes (fitted) 6220-484
Oil test vessel fitted with spherical electrodes, Pair of mushroom electrodes 6220-580
0,5 in. (12,7 mm) dia, shape B 6231-445 Pair of cylindrical electrodes 6220-483
Oil test set preparation kit 6121-486 Electrode spacing gauge for 2mm, 2.5mm and
comprising; 4mm spacing 5250-211
2 magnetic stirrers, Battery charger unit 6331-659
2 mushroom electrodes 1.4 in. (36 mm) dia., Printer lead, OTS 60PB to 25 way ‘D’ 6340-091
2 cylindrical electrodes 1 in. (25.4 mm) dia., Spare fuse 25413-285
electrode spacing gauge; 1, 2, 2,5 and 4 mm spacing User Guide 6171-585
Protective cover 5340-334
Operating instruction book 6172-064 Optional Accessories for OTS60PB
Close fitting test vessel lid 6121-402
Optional Accessories for OTS AF’s Pack of 10 reuseable/disposable oil test vessels 6220-487
Oil test vessel fitted with mushroom Lead for connection to a vehicle battery via the
electrodes, 36 mm dia, shape A 6231-447 cigar/cigarette lighter socket 6231-509
Oil test vessel fitted with cylindrical electrodes, Pair of cylindrical electrodes with 0,5 mm
1 in. (25,4 mm) dia. shape C 6231-446 edge radius 6220-538
Oil test vessel with motorised stirrer suitable Printer kit 6220-568
for testing to ASTM D1816, electrodes shape A 6111-146 Paper roll - 57,5 mm wide, 15 m long,50 mm dia. 25995-001
Transportation trolley 6111-147 Ribbon - Epson part no. ERC-09 (IRC 160) 25995-002
0-100 kV Voltage calibration check Download lead 6340-105
meter complete with case 6410-810
10.Transformer Oil
Moisture Test Set
Item 10A
KF875, KF-UNI and KF-LAB
Karl Fischer Moisture in Oil Test Sets

KF875, KF-UNI and KF-LAB


Karl Fischer Moisture in Oil Test Sets

■ Coulometric Karl Fischer titrimetry


KF875 Unit
■ KF875 optimized for insulating
oil and tests to 0.875, completely portable
■ KF-UNI offers greater flexibility,
versatility and sample data input than
the KF875; also completely portable
■ KF-LAB analyzes materials with an SG
between 0.6 & 1.4, plus insulating oils
with an SG of 0.875
■ Suitable for use with any Coulometric
KF-UNI Unit
Karl Fischer reagent

DESCRIPTION if not required and results can be calculated in ppm,


Over 20 years experience has led to the development of mg/kg, % and micrograms. For extra flexibility, the
the Megger KF875, KF-UNI and KF-LAB Coulometric Karl results may be calculated based on the weight of the
Fischer Test Sets designed to determine moisture in oil, sample or based on the volume and specific gravity
to provide highly accurate results on-site. The KF875 and of the sample.
KF-UNI are highly portable instruments, complete with
integral printer and carrying case, are easy to use and
provide highly accurate results. The KF-LAB unit is
designed specifically for lab use is mains powered only
and does not include a built-in battery or carrying case.

APPLICATION
Optimized for testing insulating oils with a specific gravity
of 0.875, the Megger KF875 simply requires the operator
to press one button and inject a 1ml sample into the test
cell. The simple ‘one touch’ operation makes the KF875 KF-LAB Unit
so easy to use that it requires no specialist knowledge or
training to use it effectively. Results are presented on the
instrument display and on the integral printer in both
The KF-LAB analyzes materials with an SG between
micrograms of water and in milligrams per kilogram
0.6 and 1.4, but also has a default setting optimized for
(parts per million, ppm).
analyzing insulating oils with an SG of 0.875. This means
The KF-UNI allows the titration of samples with a range it can be used to measure water content in a variety of
of specific gravities from 0.60 to 1.40 and also permits the different materials but is also easy to set up for transformer
use of different sample sizes. The printer may be disabled insulating oils.
KF875, KF-UNI and KF-LAB
Karl Fischer Moisture in Oil Test Sets

KF LAB KF UNI KF 875


Titration method Coulometric Karl Fischer Titration
Electrolysis control Patented “ACE” control system
End point detection AC polarisation
End point indication Visual display / print out / acoustic beep
Measuring range 1 µg – 10 mg water
Moisture range 1 ppm – 100 % 1 ppm – 100 ppm
Max. sensitivity 0.1 µg
Max. titration speed 2 mg per minute
Max. current 400 ma
Drift compensation Automatically controlled
Precision 10-100µg ± 3µg, 100µg - 1 mg ± 5µg, above 1 mg ± 0.5%
Method storage 10 programmable methods Single method Preset method
Sample ID number User programmable Not available
Display format µg, mg/kg, ppm, % mg/kg, ppm
Print format µg + mg/kg, ppm, % µg + mg/kg, ppm
Calculation modes Weight/weight Weight/weight Volume/density
Weight/dilution ratio User programmable Preset values
Volume/volume Volume/density
Volume/density User selectable
User programmable
Statistics Upto 99 runs Preset up to 99 runs
User programmable
Start delay time 0-30 mins. selectable 0-20 mins. selectable Preset
Min. titration time 0-30 mins. selectable Not available
Language English, Francais, Espanol, English
Portugues, Deutsch, Magyar
Stirrer speed Microprocessor controlled
Calendar / clock Analysis time & date print out
Keypad/User controls Non tactile membrane/display prompted menu
Display 40 character alphanumeric backlit display
Printer 42 character high speed thermal printer
Carry case Optional Standard
Power supply 90-264VAC, 47-63Hz 90-264VAC, 47-63Hz
12V DC car adapter/internal battery
Battery life Not available 8 hours running time
Battery low Not available Display & print out indication
Dimensions 250 x 245 x 120 mm
Weight 3 kg (without carry case)
KF875, KF-UNI and KF-LAB
Karl Fischer Moisture in Oil Test Sets

FEATURES AND BENEFITS ■ Each unit uses Karl Fischer coulometric titrimetry -
■ The KF875 and KF-UNI are highly portable and the industry standard method for determining moisture
designed specifically for outdoor use - both units are content (ASTM D1533, BS EN 60814:1998,
supplied as standard with a printer, low drift cell and IEC 60814:1997).
rugged carry case. Portability is further enhanced with ■ The KF875 and the KF-UNI include a rechargeable
flexible power options - both units can be powered
battery power - allows accurate on-site measurements
from the mains supply, from the internal rechargeable
to be made on oil samples freshly obtained, eliminating
battery or via a 12V car adapter.
any time deterioration of the oil sample.
■ Each unit eliminates inaccuracies with ACE Control ■ The KF875 and the KF-UNI may be powered by
System - some Coulometric Karl Fischer sets are
internal rechargeable batteries or from the supply -
susceptible to inaccuracies due to changes in electrolysis
allows field-testing and laboratory testing with the same
cell resistance, which requires frequent checking of the
equipment, providing standardization.
titrator efficiency by analyzing known water content
standards. The KF875, KF-UNI and the KF-LAB remove
this need by using the patent pending ACE
(Automatically Compensated Errors) Control System. This
guarantees that the electrolysis current produced and the
count rate displayed are always correctly synchronized,
regardless of changes to the electrolysis cell resistance
thus eliminating the need to calibrate the reagent.
This further adds to the instruments’ remarkable user-
friendliness and ease of use.

ORDERING INFORMATION
Item (Qty) Cat. No.
KF875 Coulometric Karl Fischer Test Set for insulating oils KF875 [6111-636]
KF-UNI Coulometric Karl Fischer Test Set for liquids KF-UNI [6111-637]
KF-LAB Laboratory Coulometric Karl Fischer Test Set KF-LAB [6111-638]
Supplied Accessories (also available as spare items) for the KF875 and KF-UNI ONLY
Titration Vessel 6121-527
Detector electrode 6121-528
Generator electrode 6121-529
Drying tube 6121-530
Carrying Case 6121-537
Power Pack 6121-538
Car adapter 6121-539
Supplied Accessories (also available as spare items) for the KF875, KF-UNI and KF-LAB
Injection septa (10) 6121-531
Glass syringe (1 ml) 6121-532
Luer needle 6121-533
Bottle of Molecular sieve 6121-534
Stirrer bar 6121-535
Funnel 6121-536
Supplied Accessories (also available as spare items) for the KF-LAB ONLY
Complete Glassware pack (single port) EV6121-587
Titration vessel (single port) EV6121-571
Detector electrode EV6121-572
Generator electrode EV6121-573
Drying tube EV6121-574
Teflon sleeves (pack 5 each) EV6121-575
Instruction manual EV6172-878
11. Transformer Oil
Treatment Plant
Item 11A
I–BETH49GB_0 page 1/5
OIL TREATMENT
TYPE THV 3000

TECHNICAL DESCRIPTION
OF THE VACUUM OIL TREATMENT PLANT

TYPE THV 3000


PREAMBLE

The efficient and reliable use Equipment reliability, treat ment quality and price competi-
of dielectric fluids in trans- tiveness remain the main key-points of our equipments.
formers, circuit breakers and
SUMMARY: other types of electrical THV plants have been specially designed to treat oil on a
Page equipments depends upon storage tank or a collapsible supple tank and to fill up trans-
some of their basic charac - formers.
Principle of operation 2
teristics, which in service
may be affected, resulting in Reliable and easy to use, they are particularly recommended
Main characteristics 2 reduced operating efficiency for treating oil while commissioning new transformers, or
of the electrical equipments. for treating oil tanks in workshops .
Components of the plant 2 In order to act as an insu-
lant, a coolant and an ex-
tinguishing medium, dielec -
Description of the plant 3 tric fluids must have some
basic properties, and espe-
Flow diagram 4 cially a high dielectric
strength.
Working on the principles
Options 5 of filtration, dehydration
and vacuum degasification,
the oil treat-
ment plants type THV
complete the range of stan-
dard equipments.

Oil treatment
The plants type THV electric strength to a value in excess of 75 kV Comparison between vapor and liquid phases
have been designed to treat di- after treatment. Starting from 20 ppm, mois- of moisture and dielectric oil

electric oils having a 50 ppm ture content will go down to 3 ppm* after 1 WATER
1000
moisture content and a dissolved pass. The above figures are reached with oils 100 Li id t OIL
mbars

gas content of approx. 10% by having a 10-2 mbar distillation curve at a tem- 10 Liquid oil
1 Vapor water
volume before being treated. perature of 80° C. 0,1 V il
Once the optimal treatment condi- 0,01
0
20
40
60
80

tions have been reached, the clean Evolution of the moisture content
100
120

and of the dielectric strength


treated oil goes out after 1 pass at
100 20 T °C
a maximum temperature of 70°C Dielectric strength
PPM of wate

80 15
with a moisture content below
60
KV

5 ppm* and a dissolved gas con- 10 * : Theoretical values depending on the


40 Moisture content
tent of approximately 0.1% by measuring device accuracy and ranging
20 5
from 2 to 5 ppm
volume*. This restores the oil di- 0 0
I–BETH49GB_0 page 2/5 OIL TREATMENT TYPE THV 3000

Principle of operation
Options : The dielectric fluid enters
Low speed trailer the plant through an inlet
strainer, and is then sucked
Road trailer
by vacuum* into an oil
heater, where it is heated by
immersion heaters. Then, the
dielectric fluid is sprayed
into a vacuum chamber on a
basket of degasifying rings.
Finally, the treated fluid
flows through the outlet oil
Options : pump and then passes
Plant with tarpaulin through a filter composed of
fine filtration cartridges.
Plant with metallic cover

*Oil suction must take place in a tank at atmospheric pressure.

Main characteristics
Nominal flow* during treatment in l/hr 3000
Heating power in kW 48
Total power in kW 56
Options :
Filtration** by cartridges in nominal µm 1
Transformer insulation
Limit vacuum against closed suction in mbars 0,08
High level detection system
Vacuum during treatment in mbars 0,5 to 2

* : Approximate values.
** : Consumable cartridges with filtration expressed in nominal µm.
Tropicalized electrical equipments are standard equipments on all of our plants.
Power supply 400 Volts 3 phases 50 Hz and auxiliary supply 220 Volts by transformer.

Options : Components of the plant


Voltmeter / ammeter
1 inlet coarse filter
1 direct electrical heater with 2 heating steps
1 dehydration tank
1 outlet oil motor-pump
1 cartridge filter
1 single-staged vacuum motor-pump
1 set measuring, controlling, alarming, and regulating apparatus
1 control panel
Options : 1 set of pipes, valves and accessories
3 lifting rings placed on the plant
Remote control
The plant is installed on a section iron plate with retention tray and small rubber wheels.
I–BETH49GB_0 page 3/5 OIL TREATMENT TYPE THV 3000

Description of the plant


Oil heating and filtering
Maximum suction distance in m 10 1) Oil inlet
Maximum depression in mbar -1000 The vacuum oil treatment plants type THV are equipped, at the inlet, with a
symmetrical connection (like French fire system), a strainer filter, an insulation valve and
Connection diameter in mm 40
an oil complement valve also serving as a heater drain.

Total heating power in kW 48 2) Heater


Number of thermodippers 6
The vacuum oil treatment plants type THV are equipped with a heater with
pipe stub heating casing, fitted with flanged thermodippers. The heater has 2 heating steps.
Power of an element in kW 7,8 The heater outlet is equipped with a safety valve adjusted at 4 bars, an overheating safety
thermostat, a temperature regulation probe PT100 and a manometer -1 / +5 bars.

Oil degasifying under vacuum


3) Dehydration tank
The vacuum oil treatment plants type THV are equipped with a cylindrical
dehydration cell made of steel that contains a spraying blockhead and a basket of dehy-
dration rings. The upper part of the cell is equipped with an inlet oil connection, a con-
nection to the vacuum pump, a vacuum indicator 1000 to 0 mbar and a vacuum regulation
valve. The collar is equipped with a level sensor, a low tension window with projector to
look at the lower part of the cell and a foam regulation system. The lower part is equipped
Flow in m3 /hr 170
with a flow regulation tube and a draining valve.
Limit vacuum in mbar 0,08

Motor power in kW 4

Rotation speed in rpm 1450


4) Vacuum motor-pump
The vacuum oil treatment plants type THV are equipped with a single-staged
Oil capacity in litre 5 group composed of an oil sealed rotary vane type pump with filter, anti-return valve and
Vacuum measure Manometer air ballast. The group is connected to the dehydration cell by a pipe equipped with a safety
valve, an insulating valve, a Manometer vacuum and an exhaust electro-valve of the
Auxiliary vacuum connection in mm 50
group.

Maximum flow of the pump in l/hr 7000

Pump type Centrifuge Oil outlet and fine filtration system


Height of discharge in mCE 40

Motor power in kW 3 5) Outlet oil motor pump


The outlet discharge of the vacuum oil treatment plants type THV is
Rotation speed in rpm 1500
equipped with an outlet oil motor-pump, a filter, a sampling cock, an anti-return valve, an
Pump building Cast iron/bronze insulation valve and a symmetrical connection (like French fire system).
Connection diameter in mm 40

Number of cartridges 6 6) Fine filtration system


Filter building Cast iron/steel
The vacuum oil treatment plants type THV are equipped with a consumable
cartridge filter with 1 µm nominal filtration, including a clogging control device.
Clogging control Pressostat
I–BETH49GB_0 page 4/5 OIL TREATMENT TYPE THV 3000

7) Control panel
The oil treatment plants type THV are equipped with an industrial waterproof
type cabinet in painted steel that contains the contactors, relays, fuses, connectors and wires
necessary for the equipment operation. On the door stand the buttons and warning lights of
the different equipment components.

8) Finishing painting
The oil treatment plants type THV are painted in white (RAL9002) for the sys-
tem and in blue (RAL 5012) for the platform.

9) Dimensions
Length in Width in Height in Weight in
mm mm mm kg
Plant on platform 2200 1620 2090 1500

Plant on skid 2200 1620 2890 1500

Plant on low speed trailer 2200** 1620 2320 2050

Plant on low speed trailer with tarpaulin 2200** 1620 2570 2150 * : the weight will not be
Plant on low speed trailer with metallic higher than the mentioned
2200** 1620 2570 2650 value
cover
Plant on road trailer with tarpaulin 2150** 1700 2790 2500* ** : the value does not include
the length of the draw bar
Plant on road trailer with metallic cover 2150** 1700 2790 3000*

Characteristics may be modified without any prior notice.


I–BETH49GB_0 page 5/5 OIL TREATMENT TYPE THV 3000

Options
Process controls 1) INSULATING SYSTEM
This option enables, in case of incident or of any sudden treatment failure (power cut), to insulate the plant from the electric appli-
ance to be treated and thus prevents oil from flowing into the oil treatment plant.
2) HIGH LEVEL DETECTION SYSTEM
This option enables the automatic stop of the plant when the valve which protects the vacuum pump is full. This reinforces safety and
avoids the transfer of the condensates in the vacuum pump.
3) AUTOMATIC DRAINING OF THE VALVE
This option enables an optimal protection of the vacuum network of the plant.
4) VOLTMETER / AMMETER
This option enables to visualize the power supply of the plant as well as the developed intensity in order to protect the network and
the equipment.
5) RECORDER
This option enables to record the physical dimensions characterizing the degasifying process, like temperature and vacuum.
6) QUALITY CONTROL OF OILS
Different type of laboratory or portable equipment enable you to measure the main dielectric oil characteristics.

Presentations 1) LOW SPEED TRAILER


The oil treatment can be installed on a low speed trailer with full tyres (maximum speed : 20 km/hr).
2) ROAD TRAILER
The oil treatment plant can be installed on a road trailer. The trailer has rear lighting to meet the latest European traffic regulations
requirements. The whole installation is commissioned by the French government vehicle testing service in order to be allowed to be
driven in France and in the European countries.
3) TARPAULIN PROTECTION
The plant can be equipped with a tarpaulin type protection which protects it from bad weather.
The tarpaulin can be opened on the four sides in order to enable the access to every plant components.
4) METALLIC COVER PROTECTION
The plant can be equipped with a metallic cover type protect ion which protects it from bad weather. The cover is made of aluminium
and the frame is made of iron steel. The side panels open horizontally, close per key and are maintained thanks to gas jacks. The
panels enable the access to the components of the plant.

Transformers drying 1) TRANSFORMER DRYING


(Vacuum technology) This option enables to create a vacuum in the transformer in order to dry the active parts while the oil is being treated. The pump is
installed parallel to the first one to increase the pumping capacity of the plant.
2) DOUBLE-STAGED PUMPING GROUP
In this case, the primary vacuum pump mounted on the plant is completed with a second pump stage composed of a roots.
3) AUXILIARY VACUUM CONNECTION
This option enables to have an additional vacuum connection on the plant.
4) CONDENSER AND COOLING GROUP
This option enables an optimal protection of the pump group in case of high water content treatment.

Transformers drying 1) TRANSFER PUMP


(Oil heating and transfer) This option enables to increase the length of the flexible hoses between the plant and the transformer.
2) HIGHER HEATING POWER
The standard heating power of the oil treatment plants has been calculated for a weight ratio between oil and trans-
former about 4. In case of a higher ratio, we recommend to increase the heating power of the plant.
5) CONNECTION FEATURES AND ACCESSORIES
6) SPRAYING

Telecontrol TELECONTROL standard or GSM


12.Gases and
Transformer Oil
(Portable GC for
detection of 11 Gases)
Item 12A
Mobile Gas Chromatograph for Dissolved gas Analysis Version 2
( According to DIN / IEC 60567/567 )

Scope of delivery

- basic device with Windows control


software for evaluating documentation
and customer-specific settings
- thermal-conductivity detector (TCD) and
flame ionization detector (FID),
Methanizer
- furnace cassette with separating column
and temperature-programmed column
heating system, separate heating for
each column
- internal carrier and burning gas supply (argon/hydrogen for
approximately 80 operating hours)
- 2 capillary columns for determination of hydrocarbons C1-C3 with
complete heating up to 300°C, 2. column for determination of
permanent gases ( H2, Ar, N2, O2, CO, CO2) with complete heating
up to 300°C
- Automatic, controlled gas sample valve with exchangeable 0,2 ml -
dosing capillary, integrated in basic device. The valve is suitable for
high pressure applications. Ready for operation. The sample is
pumped with an internal diaphragm pump (time controlled by
software).
- Automatic, controlled 6-port-valve, integrated in basic device. The valve is suitable for
packed as well as for capillary columns.
- degassing is carried out by means of a gas extraction syringe
according to DIN / IEC 60567/567 ; the released gas is transferred
to the GC by means of an injection syringe

For detection of 11 fault gases:

- H2, CH4, O, N, CO, CO2, C2H2, C2H4, C2H6, C3H6, C3H8

The scope of delivery includes the following components:


- Calibration gas Peakmaster
- 1 gas extraction syringe
- 1 seal assembly for the gas extraction syringe
- 2 three-way valves
- 1 two-way valve
- 2 connectors
- 1 tube connecting oil reservoir and syringe
- 1 injection syringe
- 1 Septen assembly (including 5 Septen)
- 1 unit of leakage detector gas
- 1 package of cleaning pads

following options are available:

Option: laptop as control computer:


Pentium 133 MMX
1.4 GB hard disk/16 MB RAM
12.1 inch DSTN colour LCD display with touch pad
The customer has to provide for Win 95 and Windows for Workgroups

Option: connection to external gas supply:


cylinder adapter, inert pressure pipe
needle valve for setting cylinder pressure
security pressure relief valve, filter
high-quality steel connector to the mobile GC

Option: carrier gas supply, cylinder with 2 litres of argon, 200 bar
for approximately 1,200 operating hours

Option: hydrogen supply, cylinder with 2 litres, 200 bar


for approximately 1,200 operating hours

Option: equipment case for mobile GC


The scope of delivery includes the following components:
- - 1 gas extraction syringe
- 1 seal assembly for the gas extraction syringe
- 2 three-way valves
- 1 two-way valve
- 2 connectors
- 1 tube connecting oil reservoir and syringe
- 1 injection syringe
- 1 unit of calibration gas M 218
- 1 unit of calibration gas M 216
- 2 injection syringes with cannulas
- 1 Septen?? assembly (including 5 Septen)
- 1 unit of leakage detector gas
- 1 package of cleaning pads

Multi-Tek International
103-105 Freston Road,London W11 4BD England
Tel: +44-20-73133190 Fax: +44-20-73133191
E-Mail: mti@multitekintl.com
Item 12B
TOP TOGA GC

Dissolved Gas Analysis with


automatic degassing unit
According to
IEC 567/ASTM 3612

Features and Benefits:


» Fully automatic procedure
» One touch operation
» Multi-periodic vacuum degassing
» Full TOGA analysis (11 gases)
» Automatic transfer of gas sample

Dose the oil-sample. Push ONE button.


Wait for the result.

Description
The analysis is done in 2 steps with high selectivity
and accuracy fully compliable with laboratory procedure.
1. Degassing of the oil sample through vacuum extraction
(according to IEC 567/ASTM3612 )
2. Dissolved gas analysis TCD (thermal conductivity
detector) , FID ( Flame Ionization detector) and Methanizer.
Both steps are synchronized by a micro-controller which
Top Toga GC

guarantees a fast and reliable measurement routine.


Technical Specifications
Degassing Unit
Type
» vacuum degassing procedure, oil- and mercury-free
Vacuum connections
» DN 16 KF
agkommunikation.at | lenzgrafik.com

Vacuum Pump
» diaphragm pump
» chemically resistant tree-stage
» compact modular design
» pumping speed: 2,0 m3/h
Vacuum sensor
» measuring range: 0,1 – 200 mbar
» read-out: 5 per sec
» independent of gas type
» accuracy/hysteresis: +/- 1 digit
Starting vacuum: 2 – 3 mbar
Degassing range: 2 – 200 mbar
Resolution: 0,1 mbar
Sample volume: 50-100 ml
Preconditioning time: < 5 min
Typical degassing time: < 2 min
Power supply: 230 V, 50/60 Hz; 115 V, 50/60 Hz

Gas Chromatograph
Basic unit: basic device with Windows control software for
evaluating documentation and customer-specific settings
Detectors: Thermal Conductivity Detector (TCD) and Flame
Ionisation Detector (FID), Methanizer
Columns: 2 capillary columns, Carboxen and Molesiev Column
Heating: furnace cassette with separating column and
temperature programmed column heating system, separate
heating for each column
Sample valve: Automatic, controlled gas sample valve with
exchangeable 0,2 ml – dosing capillary, integrated in basic device.

Dimensions: approx. 600 x 500 x 550 mm


Weight: 49 Kg
(comptele system)
13. Transformer Fault
Indicator (Online
Monitoring)
Item 13A
HYDROCAL 1002
Transformer Online Monitoring System

Analysis of the gases dissolved in power transformer Key Advantages


oil is recognized as the most useful tool for early
 Individual analysis of the dissolved gas con-
detection and diagnosis of incipient faults in trans-
tents hydrogen (H2) and carbon monoxide (CO)
formers.
 Simple, lightweight and easy-to-mount solution
Besides regular gas chromatographic analysis of the
without any oil extraction from the transformer
isolation oil of power transformers online monitoring
and control systems gain more and more importance  Installation on the operational transformer with-
worldwide. By online monitoring of the key fault out any supply interruption
gases an additional potential of cost reductions and  Sophisticated software showing gas contents
safety improvements can be achieved. as a bar graph, trend analysis, alarm setting di-
The HYDROCAL 1002 is a preventive maintenance rectly on the transformer and via remote commu-
device that is permanently mounted on the trans- nication on a central PC system
former. It measures continuously the most important  Easy installation on the transformer tank or
fault gases in a power transformer, hydrogen (H2) any valve on the transformer (connection to DIN
and carbon monoxide (CO). Additionally it serves for ISO 228: G 1½)
recording the fault gas contents, allows alarm levels  Maintenance-free system
to be set for each fault gas and offers output inter-  Various communication interfaces (RS 232,
faces (4-20mA) individually for H2 and CO content. RS 485, MODBUS, integrated GSM- and analog
modem)
Transformer monitoring functions
Voltages and Currents
(via voltage and current transformers /
transducer)
Temperature Monitoring
Bottom and oil temperature
(via additional temperatures sensors)
Oil humidity
(via additional humidity sensor)

Free configuration
Analogue inputs can be free allocated to
any additional sensor
Further Calculations:
Hot-Spot joint development
Loss-of-Life, with PAUWELS
Ageing Rate Belgium
Cooling Stage / Tap Changer Position
e. g. via current transducer

Remote Communication
RS 485
• Bus-Operation or point-to-point operation
• MODBUS- or proprietary protocol
• Bus length up to 1.000m
• Communication with up to 31 units HYDROCAL 1002
• Configuration via internal software
GSM modem communication
• Integrated on-board modem
• Magnetic antenna to place on Top of HYDROCAL 1002
Analogue modem communication
• Integrated on-board modem
Direct communication
• Via integrated RS 232 interface (accessible without
opening of HYDROCAL 1002 cover)
• On-site, e.g. by notebook
Sensor mounting

Transformer without cooling system Transformer with cooling system and forced oil
Mounting of the HYDROCAL 1002 sensor on a valve flow
on the transformer tank. The HYDROCAL 1002 sensor is mounted on a
Intrinsic oil circulation is assuring accomplishment of T-tube valve on the return flow from the cooling
the oil in the sensor cell system
Sensor firmware main menu
User menu External menu
• Transformer admin- • Voltage and current
istrator data measurement
• Customer / Site ad- • Bottom and top oil
ministrator data measurement
• Oil humidity meas-
urement
Gas-in-Oil menu Alarm menu
• Chart diagram H2 • Report table
and CO • Alarm acknowl-
• Result table H2 and edgement
CO
Transformer menu Configuration menu
• Aging rate • Alarm level setting
• Hot pot temperature • Communication set-
• Loss-of-life ting
• Transformer settings
/ configauration

Gas-in-Oil menu Alarm menu Communication menu

Individual chart diagram for both Display of alarm list. Details of Transmission speed adjustment
hydrogen H2 and carbon monox- each alarm and individual settings for the RS 232 / RS 485 connec-
ide CO tion
Different adjustments / settings for
the modem communication
PC-Software
Transformer administration
data
• All administration data of
a transformer can be en-
tered
• Network of different power
plants and transformer
banks can be configured
• Selective contact to each
transformer in the network
• Obtaining information of
total transformer situation
Technical data HYDROCAL 1002
Measuring Quantities Measuring range Measuring accuracy H
Hydrogen H2: 0 ppm ... 2.000 ppm ± 15 % of the measuring value ± 25 ppm
Carbon Monoxide CO: 0 ppm ... 2.000 ppm ± 20 % of the measuring value ± 25 ppm
(related to oil temperature of +55°C)
Measurement interval: 20 min.
Operation Temperature: Oil Temperature: -20°C ... +90°C
Ambient temperature: -50°C ... +55°C (below -10°C display function locked)
Temperature Coefficient: 1 % / K
Oil Pressure: 0 - 800 kpa, no vacuum allowed
Functions: Individual gas level measurement H2 and CO
Gas trend analysis (chart / bar diagram)
Different alarm level configuration
RS 232/RS 485 communication and modem communication (GSM, Modem) to
central PC Windows© software
Outputs: 2 x analogue outputs: 0/4 ... 20 mA (H2 concentration)
0/4 ... 20 mA (CO concentration)
2 x analogue outputs: 0/4 ... 20 mA (free configurable)
12 x digital outputs: 4 x 12 V relay outputs
Maximum switching values:
220 V DC, 220 V AC, 2 A, 60 W
8 x opto-coupler outputs
st
H2 alarm (H) (1 level alarm)
nd
H2 alarm (HH) (2 level alarm)
CO alarm (H)
CO alarm (HH)
Inputs: 4 x analogue inputs: 0/4 ... 20 mA
4 x analogue inputs: 0/4 ... 20 mA / 0 ... 10 V (configurable by jumpers)
Gas in oil 4 x internal gas sensors (redundant system) 2 x H2, 2 x CO
concentration Monitor: 2 x internal temperature sensors (oil temperature, gas temperature)
Communication: RS 232 (external connection, no unmounting of protective cover required)
RS 485 (bus-operation or point-to-point operation, MODBUS or proprietary pro-
tocol)
Internal on-board modem (GSM 14.4 kBit / analog 56 kBit)
Protection class: IP 55
Power supply: 110 V / 230 V ± 20 %, max. 350 VA, 50/60 Hz
Dimensions: approx. W 215 x H 215 x D 215 mm
Weight: approx. 8 kg
Connections
Item 13B
HYDROCAL 1003
Transformer Online Monitoring System with Gas-in-Oil and Mois-
ture-in-Oil Measurement

Analysis of the gases dissolved in power transformer oil is Key Advantages


recognized as the most useful tool for early detection and
 Individual analysis of the dissolved gas contents hy-
diagnosis of incipient faults in transformers.
drogen (H2) and carbon monoxide (CO)
In addition water contamination deteriorates the perform-
 Analysis of moisture (H2O) dissolved in transformer oil
ance of the oil as a high moisture content increases the
(both relative humidity in % and absolute humidity in
risk of corrosion and overheating. This is in particular
ppm)
when the water content reaches the saturation point of the
oil and free water is formed.  Simple, lightweight and easy-to-mount solution on
any valve on the transformer (connection to DIN or
Besides regular gas chromatographic analysis and off-line
NPT valves as well as via flange connection)
moisture analysis of the isolation oil of power transformers
online monitoring systems gain more and more impor-  Installation on the operational transformer without
tance worldwide. any supply interruption
By online monitoring of the key fault gases hydrogen (H2)  Sophisticated graphical-oriented software (on the
and carbon monoxide (CO) and moisture an additional device and via PC)
potential of cost reductions and safety improvements can  Various communication interfaces (RS 232, RS
be achieved. 485, MODBUS, integrated GSM- and analog modem)
 Maintenance-free system
Transformer monitoring functions
Voltages and Currents
(via voltage and current transformers /
transducer)
Temperature Monitoring
Bottom and oil temperature
(via additional temperatures sensors)
Oil humidity
(via additional humidity sensor)
Free configuration
Analogue inputs can be free allocated to
any additional sensor
Further Calculations:
Hot-Spot joint development
Loss-of-Life with PAUWELS
Ageing Rate Belgium
Cooling Stage / Tap Changer Position
(e.g. via current transducer)

Remote Communication
RS 485
• Bus-Operation or point-to-point operation
• MODBUS- or proprietary protocol
• Bus length up to 1000 m
• Communication with up to 255 units HYDROCAL 1003
• Configuration via internal software or PC software HYDROSOFT
GPS/GPRS modem communication
• Integrated on-board modem
• Magnetic antenna to place on top of HYDROCAL 1003
Analogue modem communication
• Integrated on-board modem
Direct communication
• Via integrated RS 232 interface
(accessible without opening of HYDROCAL 1003 cover)
• On-site, e.g. by notebook

Sensor mounting

Transformer without cooling system Transformer with cooling system and forced oil
Mounting of the HYDROCAL 1003 sensor on a valve on flow
the transformer tank. The HYDROCAL 1003 sensor is mounted on a T-tube
Intrinsic oil circulation is assuring accomplishment of the oil valve on the return flow from the cooling system
in the sensor cell
Sensor firmware main menu
User menu External menu
• Transformer adminis- • Voltage and current
trator data measurement
• Customer / Site admin- • Bottom and top oil
istrator data measurement
• Oil humidity measure-
ment
Gas-in-Oil menu Alarm menu
• Chart diagram H2 and • Report table
CO • Alarm acknowledge-
• Result table H2 and CO ment
Transformer menu Configuration menu
• Aging rate • Alarm level setting
• Hot spot temperature • Communication setting
• Loss-of-Live • Transformer setting
Installation

Gas-in-Oil menu Alarm menu Communication menu

Individual chart diagram for hydrogen Display of alarm list. Details of each Transmission speed adjustment for
H2, carbon monoxide CO and mois- alarm and individual settings the RS 232 connection
ture-in-oil (H2O in ppm and %) Different adjustments / settings for the
modem communication

PC-Software
Transformer administration
data
• All administration data of a
transformer can be entered
• Network of different power
plants and transformer banks
can be configured
• Selective contact to each
transformer in the network
• Obtaining information of total
transformer situation
Technical data HYDROCAL 1003
Measuring Quantities Measuring range Measuring accuracy
(related to ambient temperature +20°C and oil temperature +55°C)
Hydrogen H2: 0 ppm ... 2.000 ppm ± 15 % of the measuring value ± 25 ppm
Carbon Monoxide CO: 0 ppm ... 2.000 ppm ± 20 % of the measuring value ± 25 ppm
Moisture-in-Oil H2O: relative 0 % … 100% ± 3 % of the measuring value ± 3 ppm
absolute 0 ppm … 100ppm
Measurement interval: 20 min.
Operation Temperature: Oil Temperature: -20°C ... +90°C
Ambient temperature: -50°C ... +55°C (below -10°C display function locked)
Temperature Coefficient: 1%/K
Oil Pressure: 0 - 800 kpa, no vacuum allowed
Functions: Individual gas level measurement H2 and CO
Moisture-in-oil measurement H2O in both % and ppm
Gas/Moisture trend analysis (chart / bar diagram)
Different alarm level configuration
RS 232/RS 485 communication and modem communication (GSM, analog)
to central PC Windows© software HYDROSOFT
Outputs: 3 x analog outputs: 4 ... 20 mA (H2 concentration)
4 ... 20 mA (CO concentration)
4 … 20 mA (H2O concentration)
1 x analoge outputs: 4 ... 20 mA (free configurable)
12 x digital outputs: 4 x 12 V relay outputs (220VDC/VAC, 2A, 60W)
8 x opto-coupler outputs
st
H2/CO/H2O alarm (H) (1 level alarm)
nd
H2/CO/H2O alarm (HH) (2 level alarm)
Inputs: 4 x analogue inputs: 0/4 ... 20 mA
4 x analogue inputs: 0/4 ... 20 mA / 0 ... 10 V (configurable by jumpers)
Gas-in-oil Monitor/ 3 x internal gas sensors (redundant system) 2 x H2, 1 x CO
Moisture-in-oil Monitor: 1 x internal moisture sensor
2 x internal temperature sensors (oil temperature, gas temperature)
Communication: RS 232 (external connection, no unmounting of protective cover required)
RS 485 (bus-operation or point-to-point operation, MODBUS or proprietary protocol)
Internal on-board modem (GSM 14.4 kBit / analog 56 kBit)
Protection class: IP 55
Power supply: 110 V / 230 V ± 20 %, max. 350 VA, 50/60 Hz
Dimensions: approx. W 215 x H 215 x D 215 mm
Weight: approx. 8 kg
Connections

Edition 01.2008