Académique Documents
Professionnel Documents
Culture Documents
. \ /
1 Page
1. General Condition
Pre-assumed condition
1.5. Analysis Program (Software)
ECF (FOOTING), EXCEL, ETABS 17.
2. Design Criteria
2.1. Design and Specification Code
The structural design shall conform and in accordance with Philippine and other
reference standards
ACI 318-95 Building Code Requirement for Reinforce Concrete
UBC 1997 Uniform Building Code
NSCP 6TH EDITION National Structural Code of the Philippines 2010
ASTM C33 Standard Specifications for Concrete Aggregates
PNS 16 Philippine National Standard for C.H.B
AISC-LRFD 99
Design Loads and forces are those resulting from the self-weight of the building
Page
including all other permanent loads referred to as the Dead Loads, occupancy or non-
PREPARED BY: MARK ROGER R. HUBERIT II TIN. NO. : 296-131-421
PRC NO. : 011729 EXPIRATION DATE : 02/28/2022
PTR NO. : 0168522 DATE: MAY 22, 2018
STRUCTURE: 3 – STOREY RESIDENTIAL HOUSE DATE December 2, 2018
TYPE: RESIDENTIAL DWELLING PROJECT NO.
STATUS: Issued for Approval/Permit DESIGN BY MARK ROGER R. HUBERIT II
ISSUE: 1 OWNER MR. GABRIEL ABAD III
permanent loads referred to as the Live Loads, and earthquake loads as sometimes called
as Seismic Loads acting in most critical combinations using the appropriate load factors as
recommended by the governing national structural code of the Philippines.
K_(zt )
Page
Below are the Seismic analysis parameters for calculation of the lateral seismic
forces on the building structure:
Occupancy Importance Factor, I: 1.5 Table 208-1, Section 208.4.2 Public School Building
Page
5
Page
6
Page
Base shear
V= W^E/g[S_a]
Where: W^E Effective weight at a given mode
g Gravitational acceleration
S_a Spectral acceleration at a given mode
S_(a )= 2π/T[S_v]
Where: T Natural period of vibration
S_v Spectral velocity taken from response spectrum
7
Page
Building analysis used herein is a 3-dimensional analysis method using computer software.
Seismic analysis to calculate the lateral force used is following the procedure as stipulated in the
Uniform Building Code, UBC 1997.In this Building Analysis, the Static Lateral Force procedure
under NSCP 2015 shall be used because the building to be designed belongs to the seismic zone
4 with a height of not more than 75 meters. The structure is somehow regular in shape though
some irregularities may have been incorporated but the building is still at a height for a 3-storey
building.
Design method used is the Ultimate Strength Design method for the reinforced concrete
structures including but not limited to beams, columns, slabs and stairs. The design calculation is
governed by the current ACI 318-14 and NSCP 2015 codes, with the seismic provision in Section
418 of NSCP-2015. Furthermore, the building shall be designed with seismic connection details to
be ductile and to conform to the requirements for being a special moment resisting concrete frame
structure. The in-fill masonry partitions are assumed to have no stiffening effect on the structure.
For this 3-storey residential building, various finite model were used to check on every
structural elements modelled independently with each other. Reactions and other transfer loads
necessary for load continuity through its designated load path are maintained analysis and
modeling progresses.
Elemental Analysis & design was considered for the following structure main elements
a. Footing foundations
b. Columns
c. Beams
d. Suspended slabs
THIS SITE
9
Page