EN KEETEC EASYCAN CAN BUS MODUL MANUAL

IV. DESCRIPTION OF MODULE OUTPUTS AND THEIR FUNCTIONS


PIN FUNCTION OUTPUT DESCRIPTION

+12V pulse locking the vehicle using your


3 Lock
100 mA (0.5 sek.) original remote control
ATTENTION:Before installing, read the instructions and recommendations contained in the
manual. Equipment must be installed and used in accordance with these instructions. The device is +12V Impulse the vehicle is unlocked using
4 Unlock
designed for installation in motor vehicles with 12-volt electrical system and equipped with CAN bus 100 mA (0.5 sek.) the original remote kontrol
data. The device must be connected to 12V and negative terminals grounded. The manufacturer and the output of the LED (in the
LED (+)
retailer are not responsible for any damages resulting from improper installation, use, operation 5 programming of the code)
3 mA
or control of the product differently from the instructions for use. Incorrect repairs to the facility or
its treatment are at risk of damage to the equipment or vehicle power supply and loss guarantees. 6 Valet switch (-) input programming of the code
For proper operation and flawless product, we recommend installation of professional service.
(-)
7 Hood permanent hood open
SYSTEM DESCRIPTION 100 mA
KEETEC EASYCAN module is designed for vehicles equipped with CAN data bus and 12V 8 Doors
(-) permanent door open
supply voltage. To convert the digital signal from the data bus to analog outputs, which uses 100 mA
the car alarm when the vehicle monitoring. EASYCAN provides us with information about 9 Ground (-) ground (-)
opening doors, trunk, hood, turn on the ignition, unlock / lock the vehicle by remote control.
A detailed list of analog outputs can be found in other parts of the instructions for use. Before (-)
10 Trunk permanent trunk open
100 mA
installation into the vehicle to check the compatibility module EASYCAN according to the
attached list of supported vehicles. +12V
11 Ignition permanent Ignition
500 mA

the output is activated when the ve-


switching
I. ENTER THE CODE (-)
hicle speed does not exceed 10 km / h

EASYCAN module must be installed in the vehicles program for a specific vehicle, in which
12 Vehicle speed
100 mA KM
frequency depends on the
the module is mounted. Module set by entering the code, which can be found in the attached pulse speed of the vehicle
list of vehicles.
13 Power module +12 V power +12V
To enter the code
The output is active when the
- The list of supported vehicles to select code for the vehicle Engine rpm RPM engine speed exceeds 500 rpm
- Hold down the button on the module or service EASYCAN button car alarm (unless it is di-
rectly connected with car alarm module) for 20 sec. Until the LED lights up on the module EA-
R
Output is active for reverse
Reverse gear
SYCAN or LED on key service gear
- Release the service pin. LED goes out. Programming is started (-)
- Press the button as many times as large is the value of the first digit of the code (0 = 10but- 14 Handbrake
100 mA
permanent Output is active for handbrake
ton). After each compression LED flashes. After the required number of compression, the LED
flashes to confirm the rapid establishment of the first issue of the code. The output is active after
- In the same way, enter the second and third digit of the code Clutch
depressing the clutch pedal
- The accuracy of the code and given access to the CAN BUS to confirm by briefly pressing
the service button on the ignition. LED quickly flashes intermittently. After about 5 seconds. Low beam
The output is activated after switching
LED goes out. on dipped lights (parking) lights
- If you entered the vehicle is not in the list of supported vehicles, the LED is lit. Disconnect the
power supply module. Once again enter the access code of the vehicle. input CANBUS H (2-wire CANBUS system)
1 CAN H
input CANBUS H (1-wire CANBUS system)

2 CAN L input CANBUS L(2-wire CANBUS system)


button
V. WIRING DIAGRAM
LED orange/green
Input CAN H

orange/brown CA N Input CAN L

yellow Lock
output (+) - 100mA

II. SETTINGS OUTPUT SPEED green Unlock


Output speed can be set as pulse or switch. Pulse output setting by entering the code 911 (the output (+) - 100mA
procedure is the same as entering the code) and enter the code switching 912. Factory out-
put is set as switch. white LED
PULSE - set as the output pulse appears pulses according to vehicle speed. The output is a output (+) - 3mA (anode)
need for speed by calibration 50km/hour. When the vehicle speed reaches 50km/hour, 5
press service button on the module EASYCAN. Speed ​​is uncalibrated. In the case of incorrect purple Valet switch
calibration procedure again. input(-)
SWITCH - selected as the output switching speed to 10 km / h appears steady pulse. If the
speed rises above 10 km / h, the output pulse disappears. blue Hood

Connection EASYCAN KEETEC with car alarm KEETEC


EASY output (-) - 100mA

Some types of car alarms KEETEC a connector for direct connection to the module EASYCAN. CAN grey Doors
For car alarms, which do not have this connector, you can join by reconnecting the module output(-) - 100mA
specific inputs that you need for correct car alarm. Description of outputs and colors of wires
found in the circuit diagram. brown
Ground

green/blue Trunk
output (-) - 100mA

pink Ignition
input (+) - 500mA

white/black Speed
KM
output (-) - 100mA

red Power supply


+12V

Rpm
red/white
RPM output (-) - 100mA
(output is activated over 500 rpm)