Vous êtes sur la page 1sur 4

Powder and Porous Solid

Chemisorption/Reactivity
by Gas, Water Vapor, and Organic Vapor Sorption

© 2018 Quantachrome Corporation 0418 Rev7


Sorption Analyzers
• Carbons • Environmental Catalysis
• Fuel Cells • Batteries • Zeolites
• Industrial Catalysts • MOFs

AUTOSORB® iQ-C CHEMBET™ PULSAR™ CHEMSTAR™ TPx | TPx+

The gold standard in multi-mode gas Automated flow chemisorption analyzer The ChemStar is a fully automated dynamic
sorption technology. Advanced chemi- featuring oxidation and ammonia resis- flow chemisorption analyzer that features
sorption and physisorption capabilities tant TCD enables a wide range of methods multiple high-precision mass flow controllers
combined in a single instrument. Fully of catalyst characterization: temperature for built-in gas mixing, programmable TCD,
automated and easily programmable programmed desorption (TPD), oxidation titration loop, vapor generator, and the
in-situ treatment of chemisorption sample (TPO) and reduction/reaction (TPR/TPX), as highest temperature furnace of all the
includes gas switching and heating profiles. well as pulse titration for active surface area, Quantachrome chemisorption analyzers
User defined automatic protocols com- catalyst dispersion and nanoparticle size and which features programmable linear
bine treatment and analysis for hands-off determination. Even single- and multi-point ramping and rapid furnace cooling. The
operation. Strong and weak chemisorption BET surface area measurements are possible. software is easily programmed to perform
isotherms and temperature programming Features fully automatic gas switching, a virtually unlimited number of analysis
techniques enable the determination of furnace temperature ramping and rapid steps to extract valuable information about
active or catalyst surface metal area, (forced air) cooling, titration loop, and real surface and catalytic properties of a sample,
catalyst dispersion, nanoparticle size, time data acquisition. Built-in cold trap such as active and reactive surface areas,
hydride formation, spillover phenomena, removes undesirable condensable vapors, metal dispersion, nanoparticle size, acid/
and more. Detailed calculation and report- but can also be bypassed as required. base site distribution, and sorption energies.
ing software is provided for comprehensive
Optional external mass spectrometer Optional accessories include an external
active surface area and catalyst character-
enables the individual detection of multiple mass spectrometer with software inte-
ization.
evolved products, and includes software gration, and a sub-ambient temperature
integration of sample temperature and mass control unit.
Available in three pressure-range versions signals.
according to transducer configuration:
“C-XR” 0.1 torr, 10 torr, 1000 torr; “C-MP” 1
torr, 10 torr, 1000 torr; “AG” 1000 torr.
“C-AG” is also available without physisorp-
tion and degassing stations.
Comprehensive Physical-Chemical Assessment of Your Materials
Oxidation and ammonia resistant TCD (for Developing hierarchical zeolites with tailored surface chemistry and pore structure is at the
TPR/TPO/TPD) with or without titration forefront of optimizing fluid catalytic cracking, reforming, and a huge variety of key indus-
loop injector, is available on all models. A trial processes. Physisorption (used to determine micro-meso-macropore size distributions)
dedicated, integrated mass-spectrometer combined with chemisorption (used to quantify reactive sites) and temperature programming
option is available on “MP” and “XR” models. (used to assess the chemical and energetic heterogeneity of surfaces) provides the most
powerful approach to characterize zeolites, metal-supported catalysts, and many other solid
materials whose performance is ultimately dictated by their physical-chemical properties.
Vstar™ 2 | 4 AQUADYNE™ DVS-1 | DVS-2HT iSORB™ HP1 | HP2

The Vstar vapor sorption analyzer goes The Aquadyne DVS is a fully automated, Automated single or dual station, high
beyond water sorption to provide vapor gravimetric, water vapor sorption analyzer. pressure, volumetric gas sorption analyzer.
sorption analysis using a wide variety of It measures adsorption and desorption The instrument is capable of performing
organic vapors at a wide range of tempera- isotherms of water vapor both accurately experiments up to 200 bar at a wide
tures. Meticulous control of the manifold and sensitively with minimal operator range of temperatures thanks to various
temperature from the vapor source to the involvement. The Aquadyne DVS is thermostating options: furnace, water bath,
sample eliminates the possibility of local available with one or two sample balances. Dewar, cryocooler. The instrument is used
condensation of the adsorptive and for studies of gas storage properties such
ensures the most accurate analysis Each balance in the Aquadyne has an hydrogen, carbon dioxide, methane,
possible. outstanding resolution of ± 0.1 μg for hydride formation, heats of adsorption,
extremely precise and accurate measure- and more.
The Vstar measures complete adsorption ments. Furthermore, they can accommo-
date samples with varying adsorption The iSorbHP can also be equipped with
and desorption isotherms, that is, the
capabilities thanks to their wide dynamic a Booster system to ensure constant
quantitative uptake of vapor, as a function
range, which can be set to ± 500 mg, 0 delivery pressure of gas to the instrument
of relative pressure / relative humidity at a
to 1,000 mg, or anything in between, by (up to 200 bar), while greatly extending
user selectable, thermostatically controlled
simply modifying the counterweight. If the useful life of the gas tank, resulting in
temperature. Such measurements are of
the samples to be analyzed are of irregular reduced costs and waste of “half-empty”
critical importance to material scientists
shape or heavier than the allowed maxi- gas cylinders.
developing adsorption-based technologies
for chemical processes, pharmaceutical mum for one balance head, the Aquadyne
formulations, structural composites and DVS-2HT has the capability of combining
environmental applications, to name but both balance heads to share the load of a
a few. single sample, effectively doubling its total
maximum capacity.

Available with 2 or 4 analysis stations in a


single temperature controlled vapor dosing
environment, with sample temperatures
controlled separately from the vapor
source by precision circulating bath(s).

Visit www.quantachrome.com for more


detailed instrument specifications and
downloadable brochures.
Powder and Porous Solid

Chemisorption/Reactivity
by Gas, Water Vapor, and Organic Vapor Sorption

Comparison of Chemisorption/Reactivity Analysis Equipment at a Glance

Instrument Physisorption Organic vapor Water vapor High pressure


Mode Static Chemi Flow Chemi BET Area
Model (pore size) sorption sorption sorption

Manometric/
Autosorb iQ-C √ a √ √ c c --
Flow

ChemStar Flow -- √ b -- d d --

ChemBET Pulsar Flow -- √ b -- -- -- --

Vstar Manometric -- -- -- -- √ √ --

Aquadyne DVS Gravimetric -- -- -- -- -- √ --

iSorb HP Manometric -- -- -- -- -- -- √

a
With TCD option
b
Manual operation
c
With vapor option
d
Titration/TPD with vapor option

Catalyst Characterization by Chemisorption Selected International Standards Applicable


and Temperature Programming to Chemisorption Analysis
Many heterogeneous catalysts are actually a combination of an ASTM D4824
active phase (often a zero-valent metal) spread on an inert support Standard Test Method for Determination of Catalyst Acidity
(typically a refractory oxide or carbon). Therefore, the total area by Ammonia Chemisorption.
of the sample does not represent the catalytically active area. The
latter is also determined by gas sorption, but via the adsorption of ASTM D3903
a reactive gas (at or around room temperature) instead of an inert Standard Test Method for Hydrogen Chemisorption on
gas. The gases most commonly used are hydrogen and carbon Supported Platinum Catalysts by Volumetric Vacuum Method.
monoxide, and this technique is known as chemisorption. The ratio
of surface metal atoms to the total number of metal atoms in the WK17123
metal nanoparticles is called dispersion. The better the dispersion, New Test Method for Carbon Monoxide Chemisorption on
the more efficient the use of (expensive) metal. Supported Platinum on Alumina Catalysts using Dynamic
Flow Method.
Chemisorption catalyst characterization using temperature
programmed techniques (TPD/TPO/TPR) and pulse titration is a WK45796
popular means to characterize carbons and redox catalysts. Related New Test Method for Acid Site Characterization on Zeolites
temperature programmed (i.e. non-isothermal) methods such as Using Dynamic Flow Method.
TPR (temperature programmed reduction), TPD (temperature
programmed desorption) and TPO (temperature programmed
oxidation) are used to determine relative ease of reduction (of
oxides), oxidation (of low valency species, particularly carbons) and
Quantachrome Instruments
desorption (of ammonia from acid sites, for example). Activation
A brand of Anton Paar
energy for a given chemical process can be inferred, for example, Serving Porous 1900 Corporate Drive
Materials and Powder
from experiments performed at different heating rates. Characterization Needs Boynton Beach, FL 33426
Since 1968 800.989.2476 | 561.731.4999
Trademarks and registered trade names are the www.quantachrome.com
property of their respective owners.
© 2018 Quantachrome Corporation 0418 REV 7

Vous aimerez peut-être aussi