Vous êtes sur la page 1sur 8

Actuation Solutions and Systems for the

World’s Most Challenging Environments

AT
SERIES
Dart Valve Actuator
Durable, Accurate, Compact, Modular

• Thrusts up to 55,000 lbs


• SIL-3 Capable
• GT3 Triple Seal Gland for Severe
Service Applications
Service and support www.cowandynamics.com Actuation Solutions and Systems for the World’s Most Challenging Environments
Toll-free: 855 341 3415 info@cowandynamics.com AT SERIES – Dart
Service and support Valve Actuator
www.cowandynamics.com
PROCESS CONTROL SOLUTIONS Toll-free: 855 341 3415 info@cowandynamics.com

Cowan AT Series
Pneumatic Modulating Actuator

Control Station

Increased Yield:
• Maximize throughout by optimized control
of the dart valves
• Closed loop control with compact design
with self contained transducer
• Local control panel with closed-loop and
manual position control
Flotation Tank
Reduced Maintenance
• Transducer is protected from the harsh
environment
• No exposed transducer or clumsy linkage arms
• Modular transducer for easy installation
Cowan Pneumatic Control Panel and /or service
With and without • Remote positioner simplifies operation
local manual override and maintenance
Service and support www.cowandynamics.com Actuation Solutions and Systems for the World’s Most Challenging Environments
Toll-free: 855 341 3415 info@cowandynamics.com AT SERIES – Dart Valve Actuator

Design
Panel Protects Positioners
Exposed linkage arms are From the Environment
easily jammed, loosened or
damaged, resulting in a loss
of control

Conventional linkage arms are replaced with a


fully-enclosed transducer – a patented design
innovation by Cowan Dynamics

Toggles on the front of the panel


allow the user to quickly switch
between auto and manual modes
for easy and quick setups
Service and support www.cowandynamics.com Actuation Solutions and Systems for the World’s Most Challenging Environments
Toll-free: 855 341 3415 info@cowandynamics.com AT SERIES – Dart Valve Actuator

Compatible Positioner Brands

The AT’s cable type transducer is compatible


with the most popular brands of positioners.
PMV is our standard.

It’s also compatible with Fisher DVC6000,


Masoneilan SV2, Siemens and more. Our
engineers can help you select the appropriate
positioner to ensure compatibility.
Service and support www.cowandynamics.com Actuation Solutions and Systems for the World’s Most Challenging Environments
Toll-free: 855 341 3415 info@cowandynamics.com AT SERIES – Dart Valve Actuator

Specifications Add-Ons
Digital Positioners Digital Positioner Options
•  ero-bleed pneumatic positioner has very low air
Z
consumption to provide additional cost-savings Remote Mount
NEMA 4X/IP66 Digital positioners mounted • C
 abinets available: NEMA
• Fail Close or Open Upon loss of power remotely in a cabinet are ideal 4/4X or for hazardous areas.
• With optional Fail Last module for harsh environments and • Manual override Customized
• Intrinsically-safe version available for installation any application with difficult or to suit your application
in hazardous areas limited access to the actuator.
• Supports all key communication protocols, including:
Direct Mount
No mechanincal linkage requirement gives you the flexibility to
mount directly on the actuator or the valve in any orientation

Boosters
A2A Booster
A2A Systems are significantly They are up to 85% smaller
smaller and lighter than a and up to 45% lighter providing
conventional air tank system. a more economical solution.

Volume Booster
Volume boosters are Typically required for 10” bore
recommended with larger and above. Booster can be
modulating actuators for installed either directly on the
smooth operations. AT or in a remote panel.

Gland Seals

GT3 Gland for Harsh Environments:


Triple-seal gland with dual Options:
wipers. Rugged metallic • Low Temp
scraper and urethane • Cast iron construction for
double-acting wiper deflect applications where yellow
contamination away from the metals are not allowed
Stainless Steel AT Series with remote positioner
rod seal for long service life.
in a potash plant
Actuator Dimensions: 5”– 26” Bore

Actuation Solutions and Systems for the
World’s Most Challenging Environments

ISO AND MSS MOUNTING FLANGE

EE NPT PORT EB
(e) LBT1 or LBT2 to T5 + STROKE

DB

BD
B1

R
TE C1 OF BOLTS, D1 THREADS
MM +.000 E1 DEEP ON F1 P.C.D.
KK E A1
W B -. 0 0 2
x A deep

ISO or MSS Volume


Actuator Dimensions (in) Thrust Values (lbs)
Booster MSS Flange Mounting Dimensions (in)
Mounting Pattern*
BORE BD DB EB E EE R LB T1 LB T2 MM TE 60 PSI 80 PSI 100 PSI STD OPT (Y or No) MSS FLANGE MAX.THRUST (lbs.) A1 B1 C1 D1 E1 F1
5 3/4 ½-20 N/A 5.50 ¼ 3.32 N/A 8.88 1 3/8 N/A 1,131 1,508 1,885 F/FA07 No FA07 4,500 2.10 0.12 4 5/16-18 11/16 2.75

6 7/8 ½-20 N/A 6.50 ¼ 4.10 N/A 9.38 1 3/8 N/A 1,649 2,199 2,749 F/FA07 No FA10 9,000 2.30 0.12 4 3/8-16 11/16 4.00

7 ½ 5/8-18 N/A 7.50 3/8 4.88 N/A 8.88 1 3/8 N/A 2,262 3,016 3,770 F/FA07 No FA14 25,000 3.75 0.16 4 5/8-11 13/16 5.50

8 N/A N/A 0.56 8.50 3/8 N/A 9.50 8.88 1 3/8 7.60 2,969 3,958 4,948 F/FA10 F/FA07 No FA16 35,000 5.00 0.19 4 3/4-10 11/8 6.50

10 N/A N/A 0.81 10.75 ½ N/A 9.63 9.00 1 3/4 9.40 4,623 6,164 7,705 F/FA10 F/FA07 Y FA25 50,000 6.00 0.19 8 5/8-11 11/8 10.00

12 N/A N/A 0.81 12.75 ½ N/A 10.00 9.38 1 3/4 11.10 6,697 8,929 11,161 F/FA14 F/FA10 Y FA30 75,000 7.00 0.19 8 3/4-10 11/8 11.75

14 N/A N/A 0.94 14.88 ½ N/A 10.75 10.13 1 3/4 12.87 9,147 12,196 15,245 F/FA14 F/FA10 Y FA35 140,000 8.50 0.19 8 1-8 11/4 14.00

16 N/A N/A 1.06 17.00 ¾ N/A 11.25 10.63 2 14.85 11,875 15,834 19,792 F/FA14 F/FA10 Y FA40 230,000 9.00 0.32 8 11/4-7 11/2 16.00
18 N/A N/A 1.19 19.00 ¾ N/A 11.25 10.63 2 1/2 16.70 15,080 20,106 25,133 F/FA16 F/FA14 Y
20 N/A N/A 1.31 21.00 ¾ N/A 12.00 11.38 3 18.40 18,555 24,740 30,925 F/FA16 F/FA14 Y
ISO Flange Mounting Dimensions (mm)
24 N/A N/A 1.31 25.25 ¾ N/A 14.00 13.38 3 21.75 26,719 35,626 44,532 F/FA25 F/FA16 Y
ISO FLANGE MAX. THRUST (N) A1 B1 C1 D1 E1 F1
26 N/A N/A C/F 27.50 ¾ N/A 15.00 9.50 3 1/2 23.34 31,278 41,705 52,131 F/FA30 F/FA25 Y
F07 19,995 55 3 4 M8 11 70
Consult factory for more detailed dimensions and larger sizes MM A B KK W F10 39,990 70 3 4 M10 16 102
*Other Mounting Patterns are available; consult factory
13/8 2.25 2.00 0.75 0.88 F14 99,996 99 4 4 M16 19 140

13/4 2.25 2.38 1-14 1.13 F16 150,007 130 5 4 M20 22 165
2 2.25 2.63 1.12 1.13 F25 200,010 200 5 8 M16 22 254

21/2 2.25 3.13 1.25 1.13 F30 325,014 229 5 8 M20 22 297

3 3.50 3.75 1.25 1.25 F35 700,034 260 5 8 M30 22 356

31/2 3.50 4.25 1.28 1.25 F40 1,100,054 300 8 8 M36 22 406

Service and support www.cowandynamics.com


AT SERIES – Dart Valve Actuator
Toll-free: 855 341 3415 info@cowandynamics.com
How to Order

Actuation Solutions and Systems for the
World’s Most Challenging Environments

SERIES BORE SIZE ROD DIAMETER MOUNTINGS


AT K - 5” T - 16” I - 30” E- 1” N - 4” X1 - tie rods extended b.e. (MX1)
L - 6” W - 18” J - 32” G - 1 3/8” P - 4 1/2” X3 - tie rods extended h.e. (MX3)
ROD END M - 7” X - 20” Q - 36” H - 1 3/4” R - 5” X2 - tie rods extended c.e. (MX2)
N - 8” A - 22” U - 42” J - 2” S - 5 1/2” X0 - standard (MX0)
A4 - Series AT Female
P - 10” Y - 24” K - 2 1/2” IS - ISO mounting flange
R - 12” B - 26” L - 3” MS - MSS mounting flange
CUSHIONS
S - 14” F - 28” M - 3 1/2”
8 - none
MODS
SEALS
- Omit if none required
N - Standard Seals TRANSDUCER OPTIONS POSITIONER
A# - Thread extensions ex: A2.50 = A = 2.50”
L - Low Temp T1 - Analog output (Ratiometric) - - Omit if Poisitioner integrated with
C1 - Epoxy Paint (Non Stainless Steel parts only)
Digital output (discrete contacts) Stainless fittings and Stainless Steel
T2 - Analog output (Ratiometric) braided tubing C2 - Nickel Plate (Do not specify with C1 or C5)
PORTS T3 - Analog output (0-20 mA) S - Positioner with Stailness Steel Tubing C5 - All Stainless Steel construction*
T4 - Analog output (4-20 mA) and fittings C6 - Stainless Steel construction with Carbon Fibre barrel*
NXX - NPT
T5 - Analog output (0-5/0-10 Vdc) R - Remote Positioner LE - Lifting Lugs (8“ bore and above)
TXX - BSPT
M2 - Stainless Steel tie rods (Do not specify with C5 or C6)
** XX denotes position
M3 - Stainless Steel piston rod (Do not specify with C5 or C6)
ex: 12 = Pos 1 head, Pos 2 Cap
W# - Rod Extension ex: W2.50 = W = 2.50”
Modifications to be listed alpha numerically after the stroke #
ex:ANEA48NN11X012.0A2.50C1W5.50

EXAMPLE

AT N E A4 8 T2 R N N11 X0 12.0
AT Series 12.0 ” Stroke
8” Bore Standard mounting (MX0)
1” Rod A Series
NPT Pos 1 Both ends
Standard Seals
Remote positioner
Analog output (Ratiometric)
Non Cushioned
Series AT Female rod end

EXAMPLE WITH AUTOMATION OPTIONS

Z AT N E A4 8 X0 /00#####
Special Cylinder Unique Number assigned by Cowan Online PN Configurator *
AT Series Standard mounting (MX0)
8” Bore Non Cushioned
Series AT Female rod end
1” Rod

* Refer to Cowan Quote or Invoice for details.

Service and support www.cowandynamics.com


AT SERIES – Dart Valve Actuator
Toll-free: 855 341 3415 info@cowandynamics.com
Published December 7, 2015
Service and support www.cowandynamics.com Actuation Solutions and Systems for the
AT SERIES – Dart Valve Actuator
Toll-free: 855 341 3415 info@cowandynamics.com World’s Most Challenging Environments

Related materials Solutions Include:


Visit our website to download or request a printed catalogue.
Valve Actuators

Fail-Safe Systems

Digital Process Control Panels

Pneumatic Process Control Panels

For sales and technical information,


Contact us at:

Head Office/Factory:
6194 Notre Dame West
Montreal, Quebec H4C 1V4
TOLL-FREE: 855-341-3415

Sales Office:
211 Watline Ave, Unit 205
Mississauga, Ontario L4Z 1P3
T: 905-829-2910
TOLL-FREE: 855-341-3415
info@cowandynamics.com

/cowandynamics

/company/cowan-dynamics

/cowandynamics

/+cowandynamics

www.cowandynamics.com