Heating Nom. kW Dimensions Unit Height mm Width mm Depth mm Weight Unit kg Casing Material Fan Air flow rate - 50Hz Cooling High m³/min Low m³/min Heating High m³/min Low m³/min Sound pressure level Cooling High dBA Nom. dBA Low dBA Heating High dBA Nom. dBA Low dBA Refrigerant Type GWP Sound power level Cooling High dBA Piping connections Liquid Type OD mm Gas Type OD mm Drain Decoration panel Model Colour Dimensions Height mm Width mm Depth mm Weight kg Decoration panel 2 Model Colour Dimensions Height mm Width mm Depth mm Weight kg Decoration panel 3 Model Colour Dimensions Height mm Width mm Depth mm Weight kg Decoration panel 4 Model Colour Dimensions Height mm Width mm Depth mm Weight kg Standard Accessories Item Item Item Item Item Item Item Item Item Power supply Name Phase Frequency Hz Voltage V Notes FXZQ15A2VEB 0.043 0.036 260 575 575 15.5 Galvanised steel plate 8.5 6.5 8.5 6.5 31.5 28.0 25.5 31.5 28.0 25.5 R-410A 2,087.5 49 Flare connection 6,35 Flare connection 12.7 VP20 (I.D. 20/O.D. 26) BYFQ60C2W1W White (N9.5) 46 620 620 2.8 BYFQ60C2W1S SILVER 46 620 620 2.8 BYFQ60B2W1 White (RAL9010) 55 700 700 2.7 BYFQ60B3W1 WHITE (RAL9010) 55 700 700 2.7 1 1 1 1 8 4 2 4 7 VE 1~ 50/60 220-240/220 Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB Dimensions do not include control box The sound power level is an absolute value indicating the power which a sound source generates. Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed Maximum allowable voltage range variation between phases is 2%. MCA/MFA: MCA = 1.25 x FLA MFA ≤ 4 x FLA Next lower standard fuse rating minimum 16A Contains fluorinated greenhouse gases Instead of a fuse, use a circuit breaker Select wire size based on the value of MCA FXZQ20A2VEB 0.043 0.036 260 575 575 15.5 Galvanised steel plate 8.7 6.5 8.7 6.5 32.0 29.5 25.5 32.0 29.5 25.5 R-410A 2,087.5 49 Flare connection 6,35 Flare connection 12.7 VP20 (I.D. 20/O.D. 26) BYFQ60C2W1W White (N9.5) 46 620 620 2.8 BYFQ60C2W1S SILVER 46 620 620 2.8 BYFQ60B2W1 White (RAL9010) 55 700 700 2.7 BYFQ60B3W1 WHITE (RAL9010) 55 700 700 2.7 1 1 1 1 8 4 2 4 7 VE 1~ 50/60 220-240/220 Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB Dimensions do not include control box The sound power level is an absolute value indicating the power which a sound source generates. Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed Maximum allowable voltage range variation between phases is 2%. MCA/MFA: MCA = 1.25 x FLA MFA ≤ 4 x FLA Next lower standard fuse rating minimum 16A Contains fluorinated greenhouse gases Instead of a fuse, use a circuit breaker Select wire size based on the value of MCA FXZQ25A2VEB 0.043 0.036 260 575 575 15.5 Galvanised steel plate 9.0 6.5 9.0 6.5 33.0 30.0 25.5 33.0 30.0 25.5 R-410A 2,087.5 50 Flare connection 6,35 Flare connection 12.7 VP20 (I.D. 20/O.D. 26) BYFQ60C2W1W White (N9.5) 46 620 620 2.8 BYFQ60C2W1S SILVER 46 620 620 2.8 BYFQ60B2W1 White (RAL9010) 55 700 700 2.7 BYFQ60B3W1 WHITE (RAL9010) 55 700 700 2.7 1 1 1 1 8 4 2 4 7 VE 1~ 50/60 220-240/220 Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB Dimensions do not include control box The sound power level is an absolute value indicating the power which a sound source generates. Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed Maximum allowable voltage range variation between phases is 2%. MCA/MFA: MCA = 1.25 x FLA MFA ≤ 4 x FLA Next lower standard fuse rating minimum 16A Contains fluorinated greenhouse gases Instead of a fuse, use a circuit breaker Select wire size based on the value of MCA FXZQ32A2VEB 0.045 0.038 260 575 575 16.5 Galvanised steel plate 10.0 7.0 10.0 7.0 33.5 30.0 26.0 33.5 30.0 26.0 R-410A 2,087.5 51 Flare connection 6,35 Flare connection 12.7 VP20 (I.D. 20/O.D. 26) BYFQ60C2W1W White (N9.5) 46 620 620 2.8 BYFQ60C2W1S SILVER 46 620 620 2.8 BYFQ60B2W1 White (RAL9010) 55 700 700 2.7 BYFQ60B3W1 WHITE (RAL9010) 55 700 700 2.7 1 1 1 1 8 4 2 4 7 VE 1~ 50/60 220-240/220 Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB Dimensions do not include control box The sound power level is an absolute value indicating the power which a sound source generates. Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed Maximum allowable voltage range variation between phases is 2%. MCA/MFA: MCA = 1.25 x FLA MFA ≤ 4 x FLA Next lower standard fuse rating minimum 16A Contains fluorinated greenhouse gases Instead of a fuse, use a circuit breaker Select wire size based on the value of MCA FXZQ40A2VEB 0.059 0.053 260 575 575 16.5 Galvanised steel plate 11.5 8.0 11.5 8.0 37.0 32.0 28.0 37.0 32.0 28.0 R-410A 2,087.5 54 Flare connection 6,35 Flare connection 12.7 VP20 (I.D. 20/O.D. 26) BYFQ60C2W1W White (N9.5) 46 620 620 2.8 BYFQ60C2W1S SILVER 46 620 620 2.8 BYFQ60B2W1 White (RAL9010) 55 700 700 2.7 BYFQ60B3W1 WHITE (RAL9010) 55 700 700 2.7 1 1 1 1 8 4 2 4 7 VE 1~ 50/60 220-240/220 Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB Dimensions do not include control box The sound power level is an absolute value indicating the power which a sound source generates. Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed Maximum allowable voltage range variation between phases is 2%. MCA/MFA: MCA = 1.25 x FLA MFA ≤ 4 x FLA Next lower standard fuse rating minimum 16A Contains fluorinated greenhouse gases Instead of a fuse, use a circuit breaker Select wire size based on the value of MCA FXZQ50A2VEB 0.092 0.086 260 575 575 18.5 Galvanised steel plate 14.5 10.0 14.5 10.0 43.0 40.0 33.0 43.0 40.0 33.0 R-410A 2,087.5 60 Flare connection 6,35 Flare connection 12.7 VP20 (I.D. 20/O.D. 26) BYFQ60C2W1W White (N9.5) 46 620 620 2.8 BYFQ60C2W1S SILVER 46 620 620 2.8 BYFQ60B2W1 White (RAL9010) 55 700 700 2.7 BYFQ60B3W1 WHITE (RAL9010) 55 700 700 2.7 1 1 1 1 8 4 2 4 7 VE 1~ 50/60 220-240/220 Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB Dimensions do not include control box The sound power level is an absolute value indicating the power which a sound source generates. Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed Maximum allowable voltage range variation between phases is 2%. MCA/MFA: MCA = 1.25 x FLA MFA ≤ 4 x FLA Next lower standard fuse rating minimum 16A Contains fluorinated greenhouse gases Instead of a fuse, use a circuit breaker Select wire size based on the value of MCA