Vous êtes sur la page 1sur 3

DCDU-12B Power Cable

Contents
6.3.2.6.1.1.8 DCDU-12B Power Cable

6.3.2.6.1.1.8 DCDU-12B Power Cable


A DCDU-12B power cable feeds DC power into a DCDU-12B from power equipment. This
section describes the specifications of various DCDU-12B power cables when DCDU-12Bs are
configured in different cabinets. If external power equipment is used, the maximum length of a
DCDU-12B power cable is 10 m (32.80 ft).

Exterior
DCDU-12B power cables vary depending on power equipment. The following figure shows the
exteriors of various DCDU-12B power cables.
Figure 1 Exteriors of cables

(1) OT terminal (M6)

NOTE:
When a DCDU-12B is configured in a BTS3900L (Ver.D) cabinet, RFC (Ver.D), RFC (Ver.E), APM30H (Ver.D),
APM30H (Ver.E), TMC11H (Ver.D), or TMC11H (Ver.E), colors of the wires in a DCDU-12B power cable vary
depending on regions as follows:
 In most regions, the RTN(+) and NEG(-) wires are black and blue, respectively.
 In UK, the RTN(+) and NEG(-) wires are blue and gray, respectively.
 In mainland China, the RTN(+) and NEG(-) wires are blue and red, respectively.

Description
The following table lists the specifications of DCDU-12B power cables when DCDU-12Bs are
configured in different cabinets.

NOTE:
When a BTS3900AL is configured with RFUs and RRUs, a DCDU-03B, DCDU-11B, or DCDU-12B is used. No
power cable is needed for a DCDU-03B, DCDU-11B, or DCDU-12B, which is connected to power supply
equipment using a BusBar (in an AC cabinet) or a DC junction box (in a DC cabinet).

Table 1 Cable description

Cable Cabinet Type Power Equipment Cable Specifications


Exterior

Illustration BTS3900 (Ver.D) DC External power 35 mm2 (0.054 in.2) for one group; 16
1 cabinet equipment mm2 (0.025 in.2) for two groups

BTS3900L (Ver.D) External power 35 mm2 (0.054 in.2) for one group; 16
equipment mm2 (0.025 in.2) for two groups

TMC11H (Ver.D) External power 35 mm2 (0.054 in.2) for one group; 16
equipment mm2 (0.025 in.2) for two groups

TMC11H (Ver.E) External power 35 mm2 (0.054 in.2) for one group; 16
equipment mm2 (0.025 in.2) for two groups

RFC (Ver.D) in a DC External power 35 mm2 (0.054 in.2) for one group; 16
scenario equipment mm2 (0.025 in.2) for two groups

RFC (Ver.E) in a DC External power 35 mm2 (0.054 in.2) for one group; 16
scenario equipment mm2 (0.025 in.2) for two groups

BTS3012AE (Ver.D_Z) External power 35 mm2 (0.054 in.2) for one group; 16
DC cabinet equipment mm2 (0.025 in.2) for two groups

DBS3900 where a BBU is External power 35 mm2 (0.054 in.2) for one group; 16
installed on a wall, or equipment mm2 (0.025 in.2) for two groups
where a 19-inch rack or
IMB03 is installed
Table 1 Cable description

Cable Cabinet Type Power Equipment Cable Specifications


Exterior

Illustration RFC (Ver.D) in an AC EPU05A-02 or 25 mm2 (0.039 in.2) for one group
2 scenario EPU05A-04 in an
APM30H

RFC (Ver.E) in an AC EPU05A-06 or 25 mm2 (0.039 in.2) for one group


scenario EPU05A-08 in an
APM30H

BTS3012AE (Ver.D_Z) EPU05A-02 or 25 mm2 (0.039 in.2) for one group


AC cabinet EPU05A-04

BTS3900L (Ver.D) AC EPU05A-02 35 mm2 (0.054 in.2) for one group


cabinet

APM30H (Ver.D) EPU05A-03 or 25 mm2 (0.039 in.2) for one group


EPU05A-05 in an
APM30H

APM30H (Ver.E) EPU05A-07 or 25 mm2 (0.039 in.2) for one group


EPU05A-09 in an
APM30H

Parent Topic: DCDU Power Cables


Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >

Vous aimerez peut-être aussi